The FusionServer Pro 1288 V8 is 1U dual-socket rack server. It is the compact 1U general-purpose platform of this xFusion generation, designed for space-constrained and high-density racks. The platform runs on Intel Xeon 6 (Granite Rapids / Sierra Forest) with DDR5 memory and PCIe 5.0 expansion.

Below is the verified compatibility matrix for this model: 211 validated line items across 11 component categories and 14 certified operating-system builds, taken from xFusion’s official compatibility data and presented in English. Every part number listed is published by xFusion for this chassis; nothing is guessed or cross-filled from other models.

Form factor1u dual-socket rack
Processor range6505P – 6787P
Top core countUp to 144 cores / socket
Memory modulesDDR5 16–96GB
Memory speedUp to 8800 MT/s
Largest drive20 TB
NVMe capacityUp to 15 TB
Network speeds100GbE/10GbE/200GbE/25GbE
Power supplies900–3000W
Validated211 parts · 14 OS

Compatibility matrix

Browse validated parts by category using the tabs below. Each tab shows its item count; search inside a tab by part number or keyword, and expand the full list. Parts marked Current are actively orderable; life-cycle parts are still supported and often available as spares. The OS table lists the exact certified kernel or build.

P/NDescription / SpecificationStatus
4102Y199X86 series-FCLGA4710-2000MHz-1.6V/1.83V-64bit-350000mW-Granite Rapids-SP XCC CPU-Intel Xeon 6787P -86Core Current
4102Y201X86 series-FCLGA4710-2700MHz-1.6V/1.83V-64bit-330000mW-Granite Rapids-SP XCC CPU-Intel Xeon 6747P -48Core Current
4102Y205X86 series-FCLGA4710-2500MHz-1.6V/1.83V-64bit-250000mW-Granite Rapids-SP XCC CPU-Intel Xeon 6730P -32Core Current
4102Y206X86 series-FCLGA4710-2300MHz-1.6V/1.83V-64bit-225000mW-Granite Rapids-SP HCC CPU-Intel Xeon 6530P -32Core Current
4102Y207X86 series-FCLGA4710-2400MHz-1.6V/1.83V-64bit-210000mW-Granite Rapids-SP HCC CPU-Intel Xeon 6520P -24Core Current
4102Y209X86 series-FCLGA4710-2000MHz-1.6V/1.83V-64bit-205000mW-Granite Rapids-SP HCC CPU-Intel Xeon 6736P-36Core Current
4102Y210X86 series-FCLGA4710-3000MHz-1.6V/1.83V-64bit-255000mW-Granite Rapids-SP HCC CPU-Intel Xeon 6527P -24Core Current
4102Y211X86 series-FCLGA4710-2900MHz-1.6V/1.83V-64bit-270000mW-Granite Rapids-SP HCC CPU-Intel Xeon 6737P -32Core Current
4102Y212X86 series-FCLGA4710-3200MHz-1.6V/1.83V-64bit-190000mW-Granite Rapids-SP LCC CPU-Intel Xeon 6517P -16Core Current
4102Y213X86 series-FCLGA4710-3500MHz-1.6V/1.83V-64bit-150000mW-Granite Rapids-SP LCC CPU-Intel Xeon 6507P -8Core Current
4102Y214X86 series-FCLGA4710-2300MHz-1.6V/1.83V-64bit-150000mW-Granite Rapids-SP LCC CPU-Intel Xeon 6515P -16Core Current
4102Y215X86 series-FCLGA4710-2200MHz-1.6V/1.83V-64bit-150000mW-Granite Rapids-SP LCC CPU-Intel Xeon 6505P -12Core Current
4102Y217X86 series-FCLGA4710-1900MHz-1.6V/1.83V-64bit-250000mW-Sierra Forest-SP HDCC CPU-Intel Xeon 6766E -144Core Current
4102Y221X86 series-FCLGA4710-2400MHz-1.6V/1.83V-64bit-205000mW-Sierra Forest-SP HDCC CPU-Intel Xeon 6710E -64Core Current
4102Y250X86 series-FCLGA4710-3600MHz-1.6V/1.83V-64bit-210000mW-Granite Rapids-SP LCC CPU-Intel Xeon 6724P -16Core Current
4102Y253X86 series-FCLGA4710-3100MHz-1.6V/1.83V-64bit-300000mW-Granite Rapids-SP XCC CPU-Intel Xeon 6745P -32Core Current
90010339Liquid Manufactory Auxiliaries,Thermal Grease,X-23-7868-2D,Thermal Conductivity 3.6W/mK / 6.0W/mK,2g,Gap filling thermal conductive for customer use,1ml Current
P/NDescription / SpecificationStatus
0251Y273memory module-2288H V7-generic memory-DDR5-RDIMM-64GB-288pin-0.312ns-6400000KHz-1.1V-ECC-2Rank(4G*4bit) Current
0251Y274memory module-2288H V7-generic memory-DDR5-RDIMM-32GB-288pin-0.312ns-6400000KHz-1.1V-ECC-2Rank(2G*8bit) Current
0251Y276memory module-2288H V7-generic memory-DDR5-RDIMM-16GB-288pin-0.357ns-5600000KHz-1.1V-ECC-1Rank(2G*8bit) Current
0251Y287memory module-2288H V7-M564R32-generic memory-DDR5-RDIMM-32GB-288pin-0.312ns-6400000KHz-1.1V-ECC-2Rank(2G*8bit)-overseas dedicated Current
0251Y288memory module-2288H V7-M564R64-generic memory-DDR5-RDIMM-64GB-288pin-0.312ns-6400000KHz-1.1V-ECC-2Rank(4G*4bit)-overseas dedicated Current
0251Y289memory module-2288H V7-M564R96-generic memory-DDR5-RDIMM-96GB-288pin-0.312ns-6400000KHz-1.1V-ECC-2Rank(6G*4bit)-3-way OEM code_overseas dedicated Current
0251Y297memory module-2288H V7-M564R32-generic memory-DDR5-RDIMM-32GB-288pin-0.312ns-6400000KHz-1.1V-ECC-2Rank(2G*8bit)-Samsung 1bnm-Turin platform prohibited Current
0251Y304memory module-2288 V8-M556R64-generic memory-DDR5-RDIMM-64GB-288pin-0.312ns-6400000KHz-1.1V-ECC-2Rank(4G*4bit)-XH consumable virtual code-overseas dedicated Current
0251Y305memory module-2288 V8-M564R64-generic memory-DDR5-RDIMM-64GB-288pin-0.312ns-6400000KHz-1.1V-ECC-2Rank(4G*4bit)-XH consumable virtual code,Intel platform dedicated Current
0251Y306memory module-2288 V8-M564R32-generic memory-DDR5-RDIMM-32GB-288pin-0.312ns-6400000KHz-1.1V-ECC-2Rank(2G*8bit)-XH consumable virtual code-Intel platform dedicated Current
0251Y315memory module-2288H V7-M564R32-generic memory-DDR5-RDIMM-32GB-288pin-0.312ns-6400000KHz-1.1V-ECC-2Rank(2G*8bit)-Samsung 1bnm-Turin platform prohibited Current
0251Y317memory module-2288H V7-generic memory-DDR5-RDIMM-64GB-288pin-0.312ns-6400000KHz-1.1V-ECC-2Rank(4G*4bit) Current
0251Y321memory module-2288H V7-generic memory-DDR5-RDIMM-64GB-288pin-0.312ns-6400000KHz-1.1V-ECC-2Rank(4G*4bit) Current
0251Y325memory module-2288H V7-M564R32-generic memory-DDR5-RDIMM-32GB-288pin-0.312ns-6400000KHz-1.1V-ECC-2Rank(2G*8bit)-Samsung 1bnm-Turin platform prohibited Current
0251Y344memory module-2258 V7-M564R64-generic memory-DDR5-RDIMM-64GB-288pin-0.312ns-6400000KHz-1.1V-ECC-2Rank(4G*4bit)-Samsung 1bnm-Turin platform prohibited Current
0251Y348memory module-2288H V7-M564R96-generic memory-DDR5-RDIMM-96GB-288pin-0.312ns-6400000KHz-1.1V-ECC-2Rank(6G*4bit) Current
0620Y029-020generic memory-DDR5-RDIMM-32GB-288pin-0.312ns-6400000KHz-1.1V-ECC-2Rank(2G*8bit)-Samsung 1bnm-Turin platform prohibited Current
0620Y031-029generic memory-DDR5-RDIMM-64GB-288pin-0.312ns-6400000KHz-1.1V-ECC-2Rank(4G*4bit)-Samsung 1bnm-Turin platform prohibited Current
0620Y038generic memory-DDR5-RDIMM-16GB-288pin-0.312ns-6400000KHz-1.1V-ECC-1Rank(2G*8bit) Current
0620Y040generic memory-DDR5-RDIMM-32GB-288pin-0.312ns-6400000KHz-1.1V-ECC-2Rank(2G*8bit) Current
0620Y040-003generic memory-DDR5-RDIMM-32GB-288pin-0.312ns-6400000KHz-1.1V-ECC-2Rank(2G*8bit)-overseas dedicated Current
0620Y040-008generic memory-DDR5-RDIMM-32GB-288pin-0.312ns-6400000KHz-1.1V-ECC-2Rank(2G*8bit)-CXMT Current
0620Y042generic memory-DDR5-RDIMM-64GB-288pin-0.312ns-6400000KHz-1.1V-ECC-2Rank(4G*4bit) Current
0620Y042-003generic memory-DDR5-RDIMM-64GB-288pin-0.312ns-6400000KHz-1.1V-ECC-2Rank(4G*4bit)-Samsung 1bnm Current
0620Y042-006generic memory-DDR5-RDIMM-64GB-288pin-0.312ns-6400000KHz-1.1V-ECC-2Rank(4G*4bit)-overseas dedicated Current
0620Y042-011generic memory-DDR5-RDIMM-64GB-288pin-0.312ns-6400000KHz-1.1V-ECC-2Rank(4G*4bit)-CXMT Current
0620Y043generic memory-DDR5-RDIMM-96GB-288pin-0.312ns-6400000KHz-1.1V-ECC-2Rank(6G*4bit) Current
0620Y043-010generic memory-DDR5-RDIMM-96GB-288pin-0.312ns-6400000KHz-1.1V-ECC-2Rank(6G*4bit)-3-way OEM code_overseas dedicated Current
0620Y074generic memory-DDR5-MCRDIMM-64GB-288pin-0.227ns-8800000KHz-1.1V-ECC-2Rank(4G*4bit) Current
P/NDescription / SpecificationStatus
0254Y059generic drive module-Servers-generic drive-1200GB-SAS 12Gb/s-10000rpm-2.5inch-128MB and above-hot-swap-internal-2.5 inch bracket-V7 server dedicated Current
0254Y060generic drive module-Servers-generic drive-1200GB-SAS 12Gb/s-10000rpm-2.5inch-128MB and above-hot-swap-internal-3.5 inch bracket-V7 server dedicated Current
0254Y063generic drive module-Servers-generic drive-2400GB-SAS 12Gb/s-10000rpm-2.5inch-256MB-hot-swap-internal-2.5 inch bracket-V7 server dedicated Current
0254Y064generic drive module-Servers-generic drive-2400GB-SAS 12Gb/s-10000rpm-2.5inch-256MB-hot-swap-internal-3.5 inch bracket-V7 server dedicated Current
0254Y096generic drive module-Servers-generic drive-20TB-SATA 6.0Gb/s-7.2K rpm-3.5 inch-hot-swap-internal-3.5 inch bracket-V7 server dedicated Current
0254Y369generic drive module-Servers-generic drive-600GB-SAS 12Gb/s-10000rpm-2.5inch-128MB and above-hot-swap-internal-2.5 inch bracket-V7 server dedicated-Seagate dedicated Current
0254Y370generic drive module-Servers-generic drive-600GB-SAS 12Gb/s-10000rpm-2.5inch-128MB and above-hot-swap-internal-2.5 inch bracket-V7 server dedicated-Toshiba dedicated Current
0254Y470generic drive module-Servers-generic drive-8000GB-SATA 6.0Gb/s-7.2K rpm-3.5inch-128MB or above-hot-swap-internal-3.5 inch bracket-SEAGATE-V7 dedicated Current
0254Y691generic drive module-Servers-generic drive-20TB-SATA 6.0Gb/s-7.2K rpm-3.5 inch-hot-swap-internal-3.5 inch bracket-designated-model dedicated-Summit V7 server dedicated Current
0254Y693generic drive module-Servers-generic drive-16000GB-SATA 6.0Gb/s-7.2K rpm-3.5inch-256MB-hot-swap-internal-3.5 inch bracket-designated-model dedicated-Summit V7 server dedicated Current
0254Y700generic drive module-Servers-generic drive-600GB-SAS 12Gb/s-10000rpm-2.5inch-128MB and above-hot-swap-internal-3.5 inch bracket-V7 server dedicated-Seagate dedicated Current
0254Y702generic drive module-Servers-generic drive-600GB-SAS 12Gb/s-10000rpm-2.5inch-128MB and above-hot-swap-internal-3.5 inch bracket-V7 server dedicated-Toshiba dedicated Current
0254Y848generic drive module-Servers-generic drive-16000GB-SATA 6.0Gb/s-7.2K rpm-3.5inch-256MB-hot-swap-internal-3.5 inch bracket-WDC-Paris CP-V7 dedicated Current
0254Y849generic drive module-Servers-generic drive-16000GB-SATA 6.0Gb/s-7.2K rpm-3.5inch-256MB-hot-swap-internal-3.5 inch bracket-Toshiba-MG09-V7 dedicated Current
0254Y850generic drive module-Servers-generic drive-20000GB-SATA 6.0Gb/s-7.2K rpm-256MB-3.5 inch-hot-swap-internal-3.5 inch bracket-WDC-Paris CP-V7 dedicated Current
0254Y851generic drive module-Servers-generic drive-8000GB-SATA 6.0Gb/s-7.2K rpm-3.5inch-128MB or above-hot-swap-internal-3.5 inch bracket-Toshiba MG10Air-V7 dedicated Current
0254Y852generic drive module-Servers-generic drive-8000GB-SATA 6.0Gb/s-7.2K rpm-3.5inch-256MB-hot-swap-internal-3.5 inch bracket-WDC Vela-A1-V7 dedicated Current
0255Y347SSD module-Servers-SSD-1920GB-SATA 6Gb/s-mixed read-write-PM897 series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255Y417SSD module-Servers-SSD-480GB-SATA 6Gb/s-read-intensive-PM893 series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255Y418SSD module-Servers-SSD-480GB-SATA 6Gb/s-read-intensive-PM893 series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255Y419SSD module-Servers-SSD-960GB-SATA 6Gb/s-read-intensive-PM893 series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255Y420SSD module-Servers-SSD-960GB-SATA 6Gb/s-read-intensive-PM893 series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255Y421SSD module-Servers-SSD-1920GB-SATA 6Gb/s-read-intensive-PM893 series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255Y422SSD module-Servers-SSD-1920GB-SATA 6Gb/s-read-intensive-PM893 series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255Y423SSD module-Servers-SSD-3840GB-SATA 6Gb/s-read-intensive-PM893 series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255Y424SSD module-Servers-SSD-3840GB-SATA 6Gb/s-read-intensive-PM893 series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255Y427SSD module-Servers-SSD-480GB-SATA 6Gb/s-mixed read-write-PM897 series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255Y428SSD module-Servers-SSD-480GB-SATA 6Gb/s-mixed read-write-PM897 series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255Y429SSD module-Servers-SSD-960GB-SATA 6Gb/s-mixed read-write-PM897 series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255Y430SSD module-Servers-SSD-960GB-SATA 6Gb/s-mixed read-write-PM897 series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255Y431SSD module-Servers-SSD-1920GB-SATA 6Gb/s-mixed read-write-PM897 series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255Y432SSD module-Servers-SSD-3840GB-SATA 6Gb/s-mixed read-write-PM897 series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255Y433SSD module-Servers-SSD-3840GB-SATA 6Gb/s-mixed read-write-PM897 series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255YDUHSSD module-Servers-SSD-480GB-SATA 6Gb/s-read-intensive-SE006 series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255YDUJSSD module-Servers-SSD-480GB-SATA 6Gb/s-read-intensive-SE006 series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255YDUMSSD module-Servers-SSD-960GB-SATA 6Gb/s-read-intensive-SE006 series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255YDUNSSD module-Servers-SSD-960GB-SATA 6Gb/s-read-intensive-SE006 series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255YDURSSD module-Servers-SSD-1920GB-SATA 6Gb/s-read-intensive-SE006 series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255YDUSSSD module-Servers-SSD-1920GB-SATA 6Gb/s-read-intensive-SE006 series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255YDXASSD module-Servers-SSD-3840GB-SATA 6Gb/s-read-intensive-SE006 series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255YDXBSSD module-Servers-SSD-3840GB-SATA 6Gb/s-read-intensive-SE006 series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255YESSSSD module-Servers-SSD-3840GB-SATA 6Gb/s-read-intensive-PM893 series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255YETESSD module-Servers-SSD-480GB-SATA 6Gb/s-read-intensive-SE006 series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255YEUNSSD module-Servers-SSD-480GB-SATA 6Gb/s-read-intensive-PM893 series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255YEXMSSD module-Servers-SSD-1920GB-SATA 6Gb/s-read-intensive-SE006 series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255YEXTSSD module-Servers-SSD-1920GB-SATA 6Gb/s-read-intensive-PM893 series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255YEXWSSD module-Servers-SSD-3840GB-SATA 6Gb/s-read-intensive-SE006 series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255YEYTSSD module-Servers-SSD-960GB-SATA 6Gb/s-read-intensive-SE006 series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255YFBDSSD module-Servers-SSD-960GB-SATA 6Gb/s-read-intensive-PM893 series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0254Y058Hard Disk Module,Servers,Hard Disk,600GB,SAS 12Gb/s,10000rpm,2.5inch,128MB or above,Hot_plug,Built-in,3.5 inch Front Panel,V7 server dedicated Current Field replaceable
0255YBAQSSD Module,Servers,SSD,3840GB,NVMe PCIe,Read Intensive,PE321 Series,2.5inch(2.5inch Drive Bay),V7 dedicated Current Field replaceable
0254Y057Hard Disk Module,Servers,Hard Disk,600GB,SAS 12Gb/s,10000rpm,2.5inch,128MB or above,Hot_plug,Built-in,2.5 inch Front Panel,V7 server dedicated Current Field replaceable
0255YEGFSSD Module,Servers,SSD,3840GB,PCIE 5.0 X4,NVMe PCIe,Read Intensive,R6101 Series,2.5inch(2.5inch Drive Bay),V7 dedicated Current Field replaceable
0255YDXVSSD Module,Servers,SSD,7680GB,PCIE 5.0 X4,NVMe PCIe,Read Intensive,R6101 Series,2.5inch(2.5inch Drive Bay),V7 dedicated Current Field replaceable
0255YBASSSD Module,Servers,SSD,7680GB,NVMe PCIe,Read Intensive,PE321 Series,2.5inch(2.5inch Drive Bay),V7 dedicated Current Field replaceable
0255YBANSSD Module,Servers,SSD,1920GB,NVMe PCIe,Read Intensive,PE321 Series,2.5inch(2.5inch Drive Bay),V7 dedicated Current Field replaceable
0255YEBPSSD Module,Servers,SSD,6400GB,NVMe PCIe 5.0 X4,Mixed Use,R6301 Series,2.5inch(2.5inch Drive Bay),V7 Dedicated Current Field replaceable
0255YEDMSSD Module,Servers,SSD,12800GB,PCIE 5.0 X4,NVMe PCIe,Mixed Use,R6301 Series,2.5inch(2.5inch Drive Bay),V7 dedicated Current Field replaceable
0255YCUESSD Module,Servers,SSD,7680GB,PCIE 5.0 X4-Vendor ID 203F-Device ID 1100,2.5 inches 15mm,Read intensive,SP530 series,NVMe SSD Top-Level,2.5 inch (2.5inch Drive Bay),V7 dedicated Current Field replaceable
0255YCUDSSD Module,Servers,SSD,6400GB,PCIE 5.0 X4-Vendor ID 203F-Device ID 1100,2.5inch 15mm,Mixed use,SP630 Series,NVMe SSD Top-Level,2.5 inch (2.5inch Drive Bay),V7 dedicated Current Field replaceable
0255YDJCSSD Module,Servers,SSD,3840GB,PCIE 5.0 X4-Vendor ID 203F-Device ID 1100,2.5 inches 15mm,Read intensive,SP530 series,NVMe SSD Top-Level,2.5 inch (2.5inch Drive Bay),V7 dedicated Current Field replaceable
0255YDJESSD Module,Servers,SSD,1920GB-PCIE 5.0 X4-Vendor ID 203F-Device ID 1100,2.5 inches 15mm,Read intensive,SP530 series,NVMe SSD Top-Level,2.5 inch (2.5inch Drive Bay),V7 dedicated Current Field replaceable
0255YDJGSSD Module,Servers,SSD,3200GB,PCIE 5.0 X4-Vendor ID 203F-Device ID 1100,2.5inch 15mm,Mixed use,SP630 Series,NVMe SSD Top-Level,2.5 inch (2.5inch Drive Bay),V7 dedicated Current Field replaceable
0255YDQESSD Module,Servers,SSD,1600GB,PCIE 5.0 X4-Vendor ID 203F-Device ID 1100,2.5inch 15mm,Mixed use,SP630 Series,NVMe SSD Top-Level,2.5 inch (2.5inch Drive Bay),V7 dedicated Current Field replaceable
0255YEGHSSD Module,Servers,SSD,3200GB,NVMe PCIe 5.0 X4,Mixed Use,R6301 Series,2.5inch(2.5inch Drive Bay),V7 Dedicated Current Field replaceable
0255YFHJSSD Module,Servers,SSD,7680GB,PCIE 5.0 X4,Vendor ID 144D,Device ID A80E,Sub VID 144D-Sub DID AD05,E3.S 7.5mm,Read intensive,PM9D3a Series,NVMe SSD,V8 dedicated Current Field replaceable
0255YFHKSSD Module,Servers,SSD,3840GB,PCIE 5.0 X4,Vendor ID 144D,Device ID A900,Sub VID 144D,Sub DID AD04,E3.S 7.5mm,Read intensive,PM9D3a Series,NVMe SSD,V8 dedicated Current Field replaceable
0255YENESSD Module,Servers,SSD,15360GB,PCIE 5.0 X4-Vendor ID 1E3B-Device ID 0800,RI,R6101 Series,2.5inch(2.5inch Drive Bay),NVMe SSD,V7dedicated Current Field replaceable
P/NDescription / SpecificationStatus
0255YCEV-006SSD module-Servers-SSD-3840GB-PCIE 5.0 X4-NVMe PCIe-read-intensive-PM9D3a series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255YCEX-007SSD module-Servers-SSD-7680GB-PCIE 5.0 X4-NVMe PCIe-read-intensive-PM9D3a series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255YCFQ-003SSD module-Servers-SSD-1920GB-PCIE 5.0 X4-NVMe PCIe-read-intensive-PM9D3a series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255YCUASSD module-Servers-SSD-7680GB-PCIE 5.0 X4-Vendor ID 203F-Device ID 1100-2.5inch 15mm-read-intensive-SP530 series-NVMe SSD Top-Level-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255YCUESSD module-Servers-SSD-7680GB-PCIE 5.0 X4-Vendor ID 203F-Device ID 1100-2.5inch 15mm-read-intensive-SP530 series-NVMe SSD Top-Level-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255YDJCSSD module-Servers-SSD-3840GB-PCIE 5.0 X4-Vendor ID 203F-Device ID 1100-2.5inch 15mm-read-intensive-SP530 series-NVMe SSD Top-Level-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255YDJDSSD module-Servers-SSD-3840GB-PCIE 5.0 X4-Vendor ID 203F-Device ID 1100-2.5inch 15mm-read-intensive-SP530 series-NVMe SSD Top-Level-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255YDJESSD module-Servers-SSD-1920GB-PCIE 5.0 X4-Vendor ID 203F-Device ID 1100-2.5inch 15mm-read-intensive-SP530 series-NVMe SSD Top-Level-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255YDJFSSD module-Servers-SSD-1920GB-PCIE 5.0 X4-Vendor ID 203F-Device ID 1100-2.5inch 15mm-read-intensive-SP530 series-NVMe SSD Top-Level-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255YDXVSSD module-Servers-SSD-7680GB-PCIE 5.0 X4-NVMe PCIe-read-intensive-R6101 series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255YDXWSSD module-Servers-SSD-7680GB-PCIE 5.0 X4-NVMe PCIe-read-intensive-R6101 series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255YEBNSSD module-Servers-SSD-6400GB-NVMe PCIe 5.0 X4-mixed read-write-R6301 series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255YEBPSSD module-Servers-SSD-6400GB-NVMe PCIe 5.0 X4-mixed read-write-R6301 series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255YEDMSSD module-Servers-SSD-12800GB-PCIE 5.0 X4-NVMe PCIe-mixed read-write-R6301 series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255YEDNSSD module-Servers-SSD-12800GB-PCIE 5.0 X4-NVMe PCIe-mixed read-write-R6301 series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255YEGFSSD module-Servers-SSD-3840GB-PCIE 5.0 X4-NVMe PCIe-read-intensive-R6101 series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255YEGGSSD module-Servers-SSD-3840GB-PCIE 5.0 X4-NVMe PCIe-read-intensive-R6101 series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255YEGHSSD module-Servers-SSD-3200GB-NVMe PCIe 5.0 X4-mixed read-write-R6301 series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255YEGJSSD module-Servers-SSD-3200GB-NVMe PCIe 5.0 X4-mixed read-write-R6301 series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255YENESSD module-Servers-SSD-15360GB-PCIE 5.0 X4-read-intensive-R6101 series-2.5 inch(2.5 inch bracket)-NVMe SSD-V7 dedicated Current
0255YESMSSD module-Servers-SSD-7680GB-PCIE 5.0 X4-NVMe PCIe-read-intensive-PM9D3a series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255YFFSSSD module-Servers-SSD-15360GB-PCIE 5.0 X4-read-intensive-R6101 series-2.5 inch(3.5 inch bracket)-NVMe SSD-V7 dedicated Current
0255YFHJSSD module-Servers-SSD-7680GB-PCIE 5.0 X4-Vendor ID 144D-Device ID A80E-Sub VID 144D-Sub DID AD05-E3.S 7.5mm-read-intensive-PM9D3a series-NVMe SSD-V8 dedicated Current
0255YFHKSSD module-Servers-SSD-3840GB-PCIE 5.0 X4-Vendor ID 144D-Device ID A900-Sub VID 144D-Sub DID AD04-E3.S 7.5mm-read-intensive-PM9D3a series-NVMe SSD-V8 dedicated Current
0255YCUYSSD Module,Servers,M.2 SSD,NVMe PCIe,480GB,80.0mm * 22.0mm * 3.58 mm(Non-hot-swappable),PM9A3 series Current Field replaceable
0255Y696SSD Module,Servers,M.2 SSD,SATA 6Gb/s-240GB,80.0mm * 22.0mm * 3.58 mm(Non-hot-swappable),ER3 series Current Field replaceable
0255Y698SSD Module,Servers,M.2 SSD,SATA 6Gb/s-480GB,80.0mm * 22.0mm * 3.58 mm(Non-hot-swappable),ER3 series Current Field replaceable
0255YCULSSD Module,Servers,M.2 SSD,NVMe PCIe,960GB,80.0mm * 22.0mm * 3.58 mm(Non-hot-swappable),PJ1 series Current Field replaceable
0255Y697SSD Module,Servers,M.2 SSD,SATA 6Gb/s-480GB,80.0mm * 22.0mm * 3.58 mm(hot-swappable),ER3 series Current Field replaceable
0255YGFSSSD Module,Servers,M.2 SSD,NVMe PCIe,960GB,80.0mm * 22.0mm * 3.58 mm,PJ1 series Current Field replaceable
0255Y695SSD Module,Servers,M.2 SSD,SATA 6Gb/s-240GB,80.0mm * 22.0mm * 3.58 mm(hot-swappable),ER3 series Current Field replaceable
P/NDescription / SpecificationStatus
02312FLQfunction module-2288H V5-BC1SPSCA11-INTEL VROC KEY,advanced edition,supports RAID 0/1/10/5 Current
02312FLRfunction module-2288H V5-BC1SPSCA12-INTEL VROC KEY,standard edition,supports RAID 0/1/10 Current
0231Y131function module-9560-16i 8G-CN2M956016I8G-9560-16i 8G other board card-12G SAS RAID card-8G cache-16*12Gb/s SAS PHY-2 slimline internal interface-PCIE 4.0 X8-Vendor ID 1000-Device ID 10E2-Subvendor ID 1000-Subdevice ID 4000 Current
0231Y735function module-9540-8i-CN2M95408I-PCIE 4.0 X8-Vendor ID 1000-Device ID 10E6-1-Subvendor ID 1000-Subdevice ID 40D5-12G SAS RAID-9540-8i-x8 PCIe 4.0-9540-8i SAS RAID Card,SAS3808,No CacheVault,12Gb/s SAS,6Gb/s SATA,PCIe(NVMe)-9540-8i Current
0231Y736function module-9540-16i-CN2M954016I-PCIE 4.0 X8-Vendor ID 1000-Device ID 10E6-1-Subvendor ID 1000-Subdevice ID 40D0-12G SAS RAID-x8 PCIe 4.0-9540-16i SAS RAID Card,SAS3816,No CacheVault,12Gb/s SAS,6Gb/s SATA,PCIe(NVMe)-9540-16i Current
0256Y064RAID card module-Public Module-BC5M01RLAH1-XP270-M2-(SAS3808-BootCard)-M.2 RAID standardcard-RAID0,1,JBOD-No Cache-supports sideband management-half-height half-length-full-height bracket-PCIe 4.0 x8 Current
0256Y066RAID card module-Public Module-BC5M02RLAH1-XP270-M2-(SAS3808-BootCard)-M.2 RAID standardcard-RAID0,1,JBOD-No Cache-supports sideband management-half-height half-length-half-height bracket-PCIe 4.0 x8 Current
0256Y126RAID card module-1288 V8-BC16M03RLAEG-XC170-M-8i-(SAS3808iMR)-SAS/SATA RAID cable card-RAID0,1,10-12Gb/s-no Cache-supports sideband management(1U bracket mounting) Current
0256Y128RAID card module-1288 V8-BC16M03RLADB-XC470C-M-16i 4G-(SAS3916)-RAID cable card-RAID0,1,5,6,10,50,60-12Gb/s-4GB Cache-supports supercap & sideband management(1U bracket mounting) Current
0256Y129RAID card module-1288 V8-BC16M03RLAD-XC470C-M-8i 4G-(SAS3908)-RAID cable card-RAID0,1,5,6,10,50,60-12Gb/s-4GB Cache-supports supercap & sideband management(1U bracket mounting) Current
0256Y138RAID card module-1288 V8-BC16M05RLAEG-XC170-M-8i-(SAS3808iMR)-SAS/SATA RAID cable card-RAID0,1,10-12Gb/s-no Cache-supports sideband management(1U IO2 mounting) Current
0256Y140RAID card module-1288 V8-BC16M05RLADB-XC470C-M-16i 4G-(SAS3916)-RAID cable card-RAID0,1,5,6,10,50,60-12Gb/s-4GB Cache-supports supercap & sideband management(1U IO2 mounting) Current
0256Y141RAID card module-1288 V8-BC16M05RLAD-XC470C-M-8i 4G-(SAS3908)-RAID cable card-RAID0,1,5,6,10,50,60-12Gb/s-4GB Cache-supports supercap & sideband management(1U IO2 mounting) Current
0256Y165RAID card module-1288 V8-BC16M03RLAEC-XC370-M-16i-(SAS3816IT)-SAS/SATA RAID cable card-None RAID-12Gb/s-no Cache-supports sideband management(1U bracket mounting) Current
0256Y167RAID card module-1288 V8-BC16M05RLAEC-XC370-M-16i-(SAS3816IT)-SAS/SATA RAID cable card-None RAID-12Gb/s-no Cache-supports sideband management(1U IO2 mounting) Current
0256Y169RAID card module-1288 V8-BC16M06RLAD-XC470C-M-8i 4G-(SAS3908)-RAID cable card-RAID0,1,5,6,10,50,60-12Gb/s-4GB Cache-supports supercap & sideband management(1U front IO3 mounting) Current
0256Y170RAID card module-1288 V8-BC16M06RLAEG-XC170-M-8i-(SAS3808iMR)-SAS/SATA RAID cable card-RAID0,1,10-12Gb/s-no Cache-supports sideband management(1U front IO3 mounting) Current
0256Y174RAID card module-2288H V7-9560-8i 4G-12G SAS RAID card-9560-8i-(SAS3908)-CVPM05-12Gb/s SAS-6Gb/s SATA-PCIe(NVMe)-4G CacheVault-PCIE 4.0 X8-Vendor ID 1000-Device ID 10E2-Subvendor ID 1000-Subdevice ID 4010 Current
0256Y179RAID card module-2288H V7-9560-16i 8G-12G SAS RAID card-9560-16i-(SAS3916)-CVPM05-12Gb/s SAS,6Gb/s SATA,PCIe(NVMe)-8G CacheVault-PCIE 4.0 X8-Vendor ID 1000-Device ID 10E2-Subvendor ID 1000-Subdevice ID 4000 Current
0256Y204RAID card module-2288 V8-Dapustor F6100-PCIE 4.0 X4-Vendor ID 1e3b-Device ID 50b1-1-Subvendor ID 1e3b-Subdevice ID 50b1-PCIE 4.0 X4-Dapustor F6100 RAID Card-DP808AL-6Gb/s SATA,PCIE5.0 X2 NVMe-Chinese documentation-withthermal pad Current
0231Y129function module-9560-8i 4G-CN2M95608I4G-9560-8i 4G other board card-12G SAS RAID card-4G cache-8*12Gb/s SAS PHY-1 slimline internal interface-PCIE 4.0 X8-Vendor ID 1000-Device ID 10E2-Subvendor ID 1000-Subdevice ID 4010 EOM
0817Y002Super capacitor module,64mm*51mm*13.1mm,Wire mounting,split from 08170002,NA,7600uF,5h Current Field replaceable
0302Y201Manufactured Board-JDM,Public Module,BC55RLAD,XC470C-M-8i 4G-(SAS3908)-RAID Cable Card-RAID0,1,5,6,10,50,60-12Gb/s-4GB Cache,Capacitor and Management,PCIE 4.0 X8-Vendor ID 1000-Device ID 10E2-1-Subvendor ID 1F24-Subdevice ID 3000,1*1 Current Field replaceable
0302Y204Manufactured Board-JDM,Public Module,BC56RLAE,XC170-M-8i-(SAS3808iMR)-SAS/SATA RAID Cable Card-RAID0,1,10-12Gb/s-no Cache,Support Sideband Management,PCIE 4.0 X8-Vendor ID 1000-Device ID 10E6-1-Subvendor ID 1F24-Subdevice ID 3002,1*1 Current Field replaceable
0302Y203Manufactured Board-JDM,Public Module,BC55RLADB,XC470C-M-16i 4G-(SAS3916)-RAID Cable Card-RAID0,1,5,6,10,50,60-12Gb/s-4GB Cache, Capacitor and Management,PCIE 4.0 X8-Vendor ID 1000-Device ID 10E2-1-Subvendor ID 1F24-Subdevice ID 3001,1*1 Current Field replaceable
0256Y106RAID Card Module,2288H V7,Dapustor F6100,PCIE 4.0 X4-Vendor ID 1e3b-Device ID 50b1-1-Subvendor ID 1e3b-Subdevice ID 50b1,PCIE 4.0 X4-Dapustor F6100 RAID Card-DP808AL-6Gb/s SATA,PCIE5.0 X2 NVMe Current Field replaceable
0302Y207Manufactured Board-JDM,Public Module,BC56RLAEC,XC370-M-16i-(SAS3816IT)-SAS/SATA RAID Cable Card-None RAID-12Gb/s-no Cache,Support Sideband Management,PCIE 4.0 X8-Vendor ID 1000-Device ID 00E6-1-Subvendor ID 1F24-Subdevice ID 3007,1*1 Current Field replaceable
0302Y863Manufactured Board,2288 V8,BC16HBMA,16Port Cable SATA Controller Card,2*2 Current Field replaceable
0302Y976Manufactured Board,2288 V8,BC16HBMAA,8Port Cable SATA Controller Card,2*2 Current Field replaceable
0256Y069RAID Card Module,Public Module,9540-2M2,Vendor ID 1000-Device ID 10E6-1-Subvendor ID 1000-Subdevice ID 40E0-12G SAS RAID card,x8 PCIe 4.0-9540-2M2 SAS RAID Card,SAS3808,No CacheVault,12Gb/s SAS,6Gb/s SATA,PCIe(NVMe) Current Field replaceable
P/NDescription / SpecificationStatus
0231Y803function module-Servers-CN2M01ITGBA1-XP210 Intel I350 2*GE+half-height half-length(incl. half-height & full-height brackets)standard network adapter-PCIE 2.0 X4-Vendor ID 8086-Device ID 1521-2 Current
0231Y804function module-Servers-CN2M01ITGC1-XP212 Intel I350 4*GE+half-height half-length(incl. half-height & full-height brackets)standard network adapter-PCIE 2.0 X4-Vendor ID 8086-Device ID 1521-4 Current
0231Y809function module-Servers-CN2M04ITGG1-XP330 Ethernet adapter-10Gb optical port(Intel X710)-dual-port-SFP+(optical module not included)-half-height half-length(incl. half-height & full-height brackets)-PCIe 3.0 x8 Current
0231Y812function module-Servers-CN2M03ITGH1-XP332 Ethernet adapter-10Gb optical port(Intel XL710)-quad-port-SFP+(optical module not included)-half-height half-length(incl. half-height & full-height brackets)-PCIe 3.0 x8 Current
0231Y829function module-Servers-CN2M06ITGG1-XP330 Ethernet adapter-10Gb optical port(Intel X710)-dual-port-SFP+(incl. 2 optical modules)-half-height half-length(incl. half-height & full-height brackets)-PCIe 3.0 x8(domestic & overseas) Current
0231YAFQfunction module-Public Module-BCM957414A4142CC-function module-Fourier-BCM957414A4142CC-network adapter-25Gb optical port(BCM957414A4142CC)-dual-port-SFP28(incl. 2 optical modules)-PCIE 3.0 x8-14e4-16d7-2(domestic & overseas) Current
0257Y099PCIe-network adapter-2288H V6-E810XXVDA2G1P5-network adapter-25G optical port(E810XXVDA2G1P5 978333)-dual-port-SFP28(optical module not included)-PCIE 4.0 X8-8086-159b|0003-2-with driver package Current
0257Y102PCIe-network adapter-2288H V6-MCX631102AN-ADAT-network adapter-25 GE-64bit-SFP28-2-PCIE 4.0 x8-15b3-101f-2-with driver package Current
0257Y110PCIe-network adapter-2288H V6-LPe31002-AP-Emulex -FC HBA card-16Gb/s(LPe31002)-dual-port-SFP+(incl. 2 multimode optical modules)-PCIE 3.0 x8-Vendor ID 10DF-Device ID E300-2-Subvendor ID 10DF-Subdevice ID E310-with driver package Current
0257Y116PCIe-network adapter-2288H V6-X710T2L-10Gb/s-64bit-10GBASE-T-2 ports-PCIE 3.0 x8-8086-15ff-2-with driver package Current
0257Y117PCIe-network adapter-2288H V6-E810XXVDA4-network adapter-25G optical port(E810XXVDA4G2P5 99A2H8)-quad-port-SFP28(optical module not included)-PCIE 4.0 X16-8086-1593|0005-4-full-height half-length-with driver package Current
0257Y122PCIe-network adapter-5885H V7-LPE35000-AP-Emulex -HBA Card LPE35000-AP-FC single-port-32Gb/s-PCIE 4.0 x8-Vendor ID 10DF-Device ID F400-1-with driver package Current
0257Y123PCIe-network adapter-5885H V7-LPE35002-AP-Emulex -HBA Card LPE35002-AP-FC dual-port-32Gb/s-PCIE 4.0 x8-Vendor ID 10DF-Device ID F400-2-with driver package Current
0257Y125PCIe-network adapter-5885H V7-QLE2772-CEM-BK-Qlogic-HBA Card QLE2772-CEM-BK-FC dual-port-32Gb/s-PCIE 4.0 x8-Vendor ID 1077-Device ID 2281-2-with driver package Current
0257Y150PCIe-network adapter-2288H V6-MCX623106AN-CDAT-network adapter-100Gb optical port(MCX623106AN-CDAT)-dual-port-QSFP56(optical module not included)-half-height half-length-PCIE 4.0 x16-15b3-101d-2-with driver package Current
0257Y152PCIe-network adapter-2288H V6-N25GPCIE03-network adapter-25Gb optical port(BCM957414A4142CC)-dual-port-SFP28(optical module not included)-PCIE 3.0 x8-14e4-16d7-2-with driver package Current
0257Y246PCIe-IB card-G8600 V7-MCX755106AS-HEAT-Infiniband MCX755106AS-HEAT-200Gb/s NDR200 IB,dual-port QSFP112-PCIE 5.0 x16-Vendor ID 15B3-Device ID 1021-2-Subvendor ID 15B3-Subdevice ID 0022(optical module not included) Current
0257Y302PCIe-network adapter-2288H V6-LPE36002-LPe36002-AP-FC HBA card-64Gb/s-dual-port-PCIE 4.0 x8-Vendor ID 10df-Device ID f400-2-Subvendor ID 10df-Subdevice ID f404-with driver package Current
0257Y390PCIe-network adapter-2288H V7-MCX75310AAS-NEAT-IB card-Infiniband MCX75310AAS-NEAT-NDR/NDR200/HDR100/EDR IB single-port OSFP-400Gb/s-PCIE 5.0 x16-Vendor ID 15B3-Device ID 1021-1-Subvendor ID 15B3-Subdevice ID 0023-with driver package Current
0257Y391PCIe-network adapter-2288H V7-MCX75310AAS-HEAT-IB card-Infiniband MCX75310AAS-HEAT-200Gb/s NDR200 IB,single-port OSFP-PCIE 5.0 x16-Vendor ID 15B3-Device ID 1021-1-Subvendor ID 15B3-Subdevice ID 0029-with driver package Current
0257Y476PCIe-network adapter-2288H V7-BCM957608-P2200GQF00-network adapter-200 Gigabit-64bit-QSFP56-2 ports-PCIE 5.0 x16-Vendor ID 14e4-Device ID 1760-2-Subvendor ID 14e4-Subdevice ID 9120-with driver package Current
0257Y520PCIe-network adapter-2288H V7-BCM957508-P2100G-network adapter-100Gb optical port-dual-port-QSFP28-half-height half-length-PCIE 4.0 x16-Vendor ID 14e4-Device ID 1750-2-Subvendor ID 14e4-Subdevice ID 2100 Current
0257Y665PCIe-network adapter-2258 V7-E610XT2M5-PCIE 4.0 X4-Vendor ID 8086-Device ID 57b0-2-Subvendor ID 8086-Subdevice ID 0002 Current
0257Y821PCIe-network adapter-2258 V7-E835XXVDA2M-network adapter-2*25GE-64bit-SFP28-2 Ports-PCIE 4.0 X8-Vendor ID 8086-Device ID 124A-2-Subvendor ID 8086-Subdevice ID 0008-half-height half-length Current
0231Y810function module-Servers-CN2M01ITGH1-XP332 Ethernet adapter-10Gb optical port(Intel XL710)-quad-port-SFP+(incl. 4 optical modules)-half-height half-length(incl. half-height & full-height brackets)-PCIe 3.0 x8 EOP
3406Y008High Speed Transceiver,SFP28,850nm,25G,-8.4dBm,2.4dBm,-10.3dBm,LC,MM,0.1km,Original 34061254 split Current Field replaceable
3406Y006XFP|SFP+ Transceiver,SFP+,850nm,10Gb/s,-7.3dBm,-1dBm,-9.9dBm,LC,0.3km Current Field replaceable
3406Y011High Speed Transceiver,QSFP28,850nm,100G,-8.4dBm,2.4dBm,-10.3dBm,MPO,MM,0.1km,OM4 Original 34061089 split Current Field replaceable
3406Y007XFP|SFP+ Transceiver,SFP+,1310nm,10Gb/s,-8.2dBm,0.5dBm,-12.6dBm,LC,10km Current Field replaceable
0631Y027Network Card,100GE,64bit,QSFP56(without Optical Transceiver),2 Ports,PCIE 4.0 x16-15b3-101d-2,No Driver CD Current Field replaceable
0302Y044Manufactured Board,Public Module,CN21ITGC1,XP212 I350 4*GE PCIE Card,PCIE 2.0 X4-Vendor ID 8086-Device ID 1521-4-Subvendor ID 1f24-Subdevice ID 2001,1*2 Current Field replaceable
0302Y046Manufactured Board,Public Module,CN21ITGG1,XP330 Ethernet Adapter,10Gb Optical Interface(Intel X710),2-Port,SFP+(without Optical Transceiver),PCIE 3.0 X8-Vendor ID 8086-Device ID 1572-2-Subvendor ID 1f24-Subdevice ID 2003,1*2 Current Field replaceable
0631Y040Network Card,25 GE,64bit,SFP28,2,PCIE 4.0 x8-15b3-101f-2,No Driver CD Current Field replaceable
3406Y004Active Optical Cable Assembly,200GbE, QSFP56,IB HDR, 200Gb/s, LSZH, black pulltab,0.01km Current Field replaceable
3406Y003Active Optical Cable Assembly,200GbE, QSFP56,IB HDR, 200Gb/s, LSZH, black pulltab,0.005km Current Field replaceable
3406Y033High Speed Transceiver,SFP28,850nm,25G,-8.4dBm,2.4dBm,-10.3dBm,LC,MM,0.1km,sont split Current Field replaceable
3406Y023High Speed Transceiver,QSFP56,850nm,200Gbps,-5.9dBm,4dBm,-4.4dBm,MPO12/UPC,MM,0.1km,8636 Current Field replaceable
3406Y012High Speed Transceiver,OSFP,850nm,400Gbps,-4.6dBm,4dBm,-4.4dBm,MPO-12/APC,MM,0.05km,OM4 Dedicated to IB NDR HCA Current Engineer replace
0603Y037Other Cards,HBA Card LPe36002-AP,FC dual Ports-64Gb/s,PCIE 4.0 x8-Vendor ID 10df-Device ID f400-2-Subvendor ID 10df-Subdevice ID f404,Chinese and English doc,half width half length Current Field replaceable
06310148Network Card,25 Gigabit,64bit,SFP28(without Optical Transceiver),2 Ports,PCIE 3.0 x8-14e4-16d7-2,No Driver CD Current Field replaceable
P/NDescription / SpecificationStatus
0257Y105PCIe-network adapter-2288H V6-X710T2LOCPV3-X710T2LOCPV3 Ethernet adapter-2*10GE(Intel X710)-dual-port-RJ45-PCIE 3.0 x8-8086-15FF-2-with driver package-OCP Current
0257Y107PCIe-network adapter-2288H V6-E810XXVDA2OCP3G-Ethernet adapter-25GE(Intel E810)-dual-port-SFP28-PCIE 4.0 x8-Vendor ID 8086-Device ID 159b-2-Subvendor ID 8086-Subdevice ID 0005-with driver package-OCP Current
0257Y131PCIe-network adapter-2288H V6-BCM957508-N2100G-network adapter-100 Gigabit-64bit-QSFP28-2 ports-PCIE 4.0 x16-14e4-1750-2,OCP-with driver package Current
0302Y054manufactured board-JDM-Public Module-BC53ETHF-XC310 GE350-T2 OCP3.0 Ethernet adapter-2*GE(I350)-dual-port-RJ45,PCIE 2.1 x4-Vendor ID 8086-Device ID 1521-2-Subvendor ID 1f24-Subdevice ID 200b-1*4 Current
0302Y237manufactured board-JDM-Public Module-BC53ETHH-XC331 OCP3.0 Ethernet adapter-10GE(BCM57416)-dual-port-RJ45-PCIE 3.0 X8-Vendor ID 14e4-Device ID 16d8-2-Subvendor ID 1f24-Subdevice ID 2010-1*3 Current
0302Y238manufactured board-JDM-Public Module-BC55ETHA-XC385 OCP3.0 Ethernet adapter-25GE(CX6-Lx)-dual-port-SFP28(optical module not included)-PCIE 4.0 X8-Vendor ID 15b3-Device ID 101f-2-Subvendor ID 1f24-Subdevice ID 2011-1*4 Current
0302Y239manufactured board-JDM-Public Module-BC55ETHB-XC381 OCP3.0 Ethernet adapter-25GE(E810)-dual-port-SFP28(optical module not included)-PCIE 4.0 X8-Vendor ID 8086-Device ID 159b-2-Subvendor ID 1f24-Subdevice ID 2012-1*4 Current
0302Y434manufactured board-JDM-Public Module-BC53ETHI-XC386 OCP3.0 Ethernet adapter-25GE(BCM57414)-dual-port-SFP28(optical module not included)-PCIE 3.0 X8-Vendor ID 14e4-Device ID 16d7-2-Subvendor ID 1f24-Subdevice ID 2013-1*4 Current
0302Y435manufactured board-JDM-Public Module-BC53ETHJ-XC333 OCP3.0 Ethernet adapter-10GE(BCM57412)-dual-port-SFP+(optical module not included)-PCIE 3.0 X8-Vendor ID 14e4-Device ID 16d6-2-Subvendor ID 1f24-Subdevice ID 2014-1*4 Current
0631Y043Network Card,100 Gigabit,64bit,QSFP28,2 ports,PCIE 4.0 x16-14e4-1750-2,No Driver CD,OCP Current Field replaceable
P/NDescription / SpecificationStatus
02313ADYfunction module-TS200-2280-BC11TPMC02-TPM2.0 card(SPI)-China dedicated Current
02313APLfunction module-TS200-2280-BC11TPMA02-TPM2.0 card(SPI)-international dedicated Current
03028HYWManufactured Board,TaiShan 200 (Model 2280),BC11TPMD,TPM2.0 Card(SPI), China Dedicated,5*4 Current Engineer replace
03024QEHManufactured Board,2288H V5,BC11TPMA,TPM2.0 Card(SPI), Overseas Dedicated,5*4 Current Engineer replace
P/NDescription / SpecificationStatus
0258Y601IO expansion module-drive-1288 V8-BC16M13HBMA-internal M.2 riser/adapter card,supports SATA media(1U bracket mounting)-supports two M.2 media slot NONE
0258Y731IO expansion module-drive-1288 V8-BC16M16HBMA-internal M.2 riser/adapter card,supports SATA media(1U front IO3 mounting)-supports two M.2 media slot NONE
0302012412manufactured board-1288H V7-BC15HBBG-4*3.5 inch SAS/SATA standard drive backplane-1*4 NONE
0302012413manufactured board-1288H V7-BC15HBBH-8*2.5 inch SAS/SATA standard drive backplane-1*3 NONE
0302012468manufactured board-1288H V7-BC15HBBD-rear 2*2.5 inch SAS/SATA drive backplane-2*3 NONE
0302Y689manufactured board-2158H V8-BC26HBMA-PCIe to SATA M.2 backplane-1*1 NONE
0302Y880manufactured board-1288 V8-BC16NHBE-10*2.5 inch(6*SAS/SATA+4*SAS/SATA/NVMe)drive backplane-1*3 NONE
0302Y947manufactured board-1288 V8-BC15NHBZ-8*2.5 inch SAS/SATA/NVMe hard RAID drive backplane-1*3 NONE
0302Y962manufactured board-BC19NHBC--rear IO3 2*2.5"SAS/SATA/NVME horizontal drive backplane 1-2*2 NONE
0302YABVmanufactured board-1288 V8-BC16EHBB-8*E3.S 1T NVMe 3Cage drive backplane-1*3 NONE
0302YACBmanufactured board-BC16NHBG--10*2.5 inch(10*SAS/SATA/NVMe)drive backplane-1*3 NONE
0302YACCmanufactured board-BC19NHBDA--rear IO3 2*2.5"SAS/SATA/NVME horizontal drive backplane 2-2*2 NONE
P/NDescription / SpecificationStatus
02313XSFserver platinum 900W 2.0 versionAC power supply-ST(model PAC900S12-B2,interface IEC 320-C14) Current
0231Y019server platinum 2000W 2.0 versionAC power supply(model PAC2000S12-B1,interface IEC 320-C14) Current
0231Y021HVDC1500WB power supply module(model PHD1500S12-B2,interface Rongfeng RF-203 high-voltage input terminal) Current
0231Y025server titanium 2000W AC power supply module(model PAC2000S12-T1,interface IEC 320-C14) Current
0231Y033server platinum 1500W 2.0 versionAC power supply(model PAC1500S12-B1,interface IEC 320-C14) Current
0231Y265900W titanium AC power supply(model PAC900S12-T1,interface IEC 320-C14) Current
0231Y493server DC power supply-68mm-1200W-air-cooled(incl. DC power cord)(model PDC1200S12-CF1,interface Phoenix SPT 5/3-H-7,5-ZB model crimp terminal) Current
0231YEKUprimary power supply-XA3000-server titanium 3000W AC power supply(model XA3000,interface IEC 320-C20) Current
0231Y017server platinum 900W 2.0 versionAC power supply(model PAC900S12-B2,interface IEC 320-C14) EOM
0231Y020Function Module,PDC1200S12-CF,Server 1200W DC power supply 48V Current Field replaceable
P/NDescription / SpecificationStatus
0255Y695SSD module-Servers-M.2 SSD-SATA 6Gb/s-240GB-80.0mm * 22.0mm * 3.58 mm(hot-swappable)-ER3 series Current
0255Y696SSD module-Servers-M.2 SSD-SATA 6Gb/s-240GB-80.0mm * 22.0mm * 3.58 mm(non-hot-swappable)-ER3 series Current
0255Y697SSD module-Servers-M.2 SSD-SATA 6Gb/s-480GB-80.0mm * 22.0mm * 3.58 mm(hot-swappable)-ER3 series Current
0255Y698SSD module-Servers-M.2 SSD-SATA 6Gb/s-480GB-80.0mm * 22.0mm * 3.58 mm(non-hot-swappable)-ER3 series Current
0255Y928SSD module-Servers-M.2 SSD-NVMe PCIe-1920GB-110.0mm * 22.0mm * 3.58 mm(non-hot-swappable)-PM9A3 series Current
0255YCTNSSD module-Servers-M.2 SSD-NVMe PCIe-960GB-110.0mm * 22.0mm * 3.8 mm(non-hot-swappable)-PM9A3 series Current
0255YCULSSD module-Servers-M.2 SSD-NVMe PCIe-960GB-80.0mm * 22.0mm * 3.58 mm(non-hot-swappable)-PJ1 series Current
0255YCUYSSD module-Servers-M.2 SSD-NVMe PCIe-480GB-80.0mm * 22.0mm * 3.58 mm(non-hot-swappable)-PM9A3 series Current
0255YFBASSD module-Servers-M.2 SSD-SATA 6Gb/s-480GB-80.0mm * 22.0mm * 3.58 mm(hot-swappable)-ER3 series Current
0255YFDHSSD module-Servers-M.2 SSD-NVMe PCIe-480GB-80.0mm * 22.0mm * 3.58 mm(non-hot-swappable)-PM9A3 series Current
0255YFEJSSD module-Servers-M.2 SSD-NVMe PCIe-960GB-110.0mm * 22.0mm * 3.8 mm(non-hot-swappable)-PM9A3 series Current
0255YGFSSSD module-Servers-M.2 SSD-NVMe PCIe-960GB-80.0mm * 22.0mm * 3.58 mm-PJ1 series Current
0256Y131RAID card module-1288 V8-BC16M03HBMAA-BC16HBMAA-8 port SATA cable card-no RAID-6Gb/s-no Cache(1U bracket mounting) Current
0256Y143RAID card module-1288 V8-BC16M05HBMAA-BC16HBMAA-8 port SATA cable card-no RAID-6Gb/s-no Cache(1U IO2 mounting) Current
0256Y171RAID card module-1288 V8-BC16M06HBMAA-BC16HBMAA-8 port SATA cable card-no RAID-6Gb/s-no Cache(1U front IO3 mounting) Current
90010339Liquid Manufactory Auxiliaries,Thermal Grease,X-23-7868-2D,Thermal Conductivity 3.6W/mK / 6.0W/mK,2g,Gap filling thermal conductive for customer use,1ml Current Engineer replace
43020237SAS Expander,NA,VROC KEY,RAID 0/1/10/5,Premium,100mW,0.125MB/s Current Engineer replace
03026ALFManufactured Board-JDM,1288H V6,BC13CPIA,1U 4*3.5inch HDD Panel Interface Board,1*5 Current Engineer replace
0231YDVTFunction Module,2158H V8,BC1M12ERISE,2158H V8 Unpacking Inspection Module Current Field replaceable
0302YABTManufactured Board,2288 V8,BC16MBSCA,1288 V8/2288 V8 Server Motherboard,1*1 Current Field replaceable
0302Y855Manufactured Board,2288 V8,BC16MBSC,1288 V8/2288 V8 Server motherboard,1*1 Current Field replaceable
0231YGABFunction Module,2288 V8,BC16M01INTRD,2288 V8 Intrude Detection Module Current Engineer replace
0302Y884Manufactured Board,BC16CPIC,Fornt IO Board(3Cage Configuration),1*10 Current Field replaceable
0258Y586IO Extended Module-PCIE,1288 V8,BC16M01PRUF,1*16X SLOT(PCIE5.0) module Current Engineer replace
0258Y585IO Extended Module-PCIE,1288 V8,BC16M01PRUJ,1*16X SLOT(PCIE5.0)+1*16X SLOT(PCIE5.0) module Current Engineer replace
0258Y609IO Extended Module-Hard Disk,1288 V8,BC16M15HBMA,Built in M.2 riser card, Supporting SATA media(1U IO2 install),Supports two M.2 media slots Current Engineer replace
0258Y729IO Extended Module-PCIE,1288 V8,BC16M02PRUFB,1*16X SLOT(PCIE5.0)-Front IO3 module Current Field replaceable
0258Y726IO Extended Module-PCIE,1288 V8,BC16M02PRUDA,2*16X+2*8X SLOT(PCIE5.0)-Front IO1+IO2 module Current Field replaceable
0258Y728IO Extended Module-PCIE,1288 V8,BC16M01PRUFB,1*8X SLOT(PCIE5.0)-Front IO3 module Current Field replaceable
0258Y727IO Extended Module-PCIE,1288 V8,BC16M03PRUDA,2*8X SLOT(PCIE5.0)-Front IO1 module Current Field replaceable
0258Y732IO Extended Module-PCIE,1288 V8,BC16M01PRUDA,2*16X+2*16X SLOT(PCIE5.0)-Front IO1+IO2 module Current Field replaceable
0258Y735IO Extended Module-Hard Disk,1288 V8,BC16M11NHBCD,4*2.5" SAS/SATA/NVMe pass-through 3Cage Disk Backplane Module Current Field replaceable
0258Y731IO Extended Module-Hard Disk,1288 V8,BC16M16HBMA,Built in M.2 riser card, Supporting SATA media(1U Front IO3 install),Supports two M.2 media slots Current Engineer replace
0258Y601IO Extended Module-Hard Disk,1288 V8,BC16M13HBMA,Built in M.2 riser card, Supporting SATA media(1U bracket install),Supports two M.2 media slots Current Engineer replace
0258Y730IO Extended Module-Hard Disk,1288 V8,BC16M11HBBD,2*2.5" Rear Hard Disk Backplane Module Current Field replaceable
P/NDescription / SpecificationStatus
04052259Power cord,China AC Power 250V2.5A,2.0m,PISM,227IEC53-0.75^2(3C),C5SF,250V,2.5A,Black Current Engineer replace
04051080Power cord,South Africa AC Power 250V10A,3m,PMAM,H05VV-F-1.0mm^2(3C),C13SF,250V,10A,Black Current Engineer replace
04041119Power Cable,Switzerland AC Power Cable 250V10A,3.0m,PJSM ,H05VV-F-1.0mm^2(3C),C13SF,Black Current Engineer replace
04050517Power Cable,China AC Power Cable 250V10A,2.0m,PISM,227IEC53(RVV)1.0mm^2(3C),C13SF,Black Current Engineer replace
0415G005Power cord,China AC Power 250V10A,2.0m,C14SM,227IEC53-1.0^2(3C),C13SF,PDU Cable Current Engineer replace
0405G02CPower Cords Cable,China AC Power 250V10A,0.8m,C14SM,227IEC53 1.0^2(3C),C13SF,PDU Cable Current Engineer replace
0405G02DPower Cords Cable,Japan AC Power 250V12A,1.8m,C14SM,HVCTF 1.25^2(3C),C13SF,PDU Cable Current Engineer replace
04050955Power Cords Cable,China AC Power,250V10A,1.5m,PISM,227IEC53(RVV)1.0mm^2(3C),C13SF,250V,10A,Black Current Engineer replace
0405G02FPower Cords Cable,Australia AC Power 250V10A,1.8m,C14SM,H05VV-F-1.0^2(3C),C13SF,PDU Cable Current Engineer replace
04041117Power Cable,Britain AC Power Cable 250V10A,3.0m,PGAM ,H05VV-F-1.0mm^2(3C),C13AF-L,Black Current Engineer replace
0405G02HPower Cords Cable,Korea AC Power 250V10A,1.8m,C14SM,H05VV-F-1.0^2(3C),C13SF,PDU Cable Current Engineer replace
0405G02KPower Cords Cable,Denmark AC Power 250V10A,3m,PKSM,H05VV-F-3*1.0^2(3C),C13SF,Black Current Engineer replace
0405G028Power Cords Cable,Korea AC Power 250V10A,3m,PFSM,H05VV-F 3*1.0^2(3C),C13SF,Black Current Engineer replace
04050588Power cord,China AC Power Cable250V10A,1.5 m,C14SM,(227IEC53(RVV)1.0mm^2(3C)),C13SF,250V,10A,White,PDU Cable Current Engineer replace
0405G029Power Cords Cable,North America AC Power 250V10A,1.8m,C14SM,SJT 18AWG(3C),C13SF,PDU Cable Current Engineer replace
04050784Power Cords Cable,China AC Power Cable,250V16A,2m,C14SM,227IEC53-1.0^2(3C),C13SF,Yellow Current Engineer replace
04051035Power cord,India AC Power 250V6A,3m,PM-IIAM,IS 694-1.0^2(3C),C13 SF,250V,6A,Black Current Engineer replace
04050188Power Cords Cable,China AC Power 250V10A,1.5m,C14SM,227IEC53(RVV)1.0mm^2(3C),C13SF,PDU Cable Current Engineer replace
04020728Power Cable,America AC Power Cable,125V10A,3.0m,PBSM,18SJT(3C),C13SF,Black Current Engineer replace
04042698Power Cords Cable,China AC Power 250V10A,15.0m,PISM,227IEC53-1.0^2(3C),C13SF,Black Current Engineer replace
04042697Power Cords Cable,China AC Power 250V10A,10.0m,PISM,227IEC53-1.0^2(3C),C13SF,Black Current Engineer replace
04042699Power Cords Cable,China AC Power 250V10A,20.0m,PISM,227IEC53-1.0^2(3C),C13SF,Black Current Engineer replace
04041120Power Cable,Italy AC Power Cable 250V10A,3.0m,PLSM,H05VV-F-1.0mm^2(3C),C13SF,Black Current Engineer replace
04047785Power Cords Cable,Argentina AC Power 250V10A,3.0m,PISM,H05VV-F-1.0mm^2(3C),C13SF,Black Current Engineer replace
04051020High Speed Cable,Internal Mini SAS HD Cable,0.75m,Internal Mini SAS HD R/A,8*(1P*30AWG+ 2*Drain)+8C*30AWG,Internal Mini SAS HD STR,R/A-STR Current Engineer replace
04052137Power cord,Taiwan AC 125V11A,3.0m,PBSM,HVCTF 3*1.25mm2,C13SF,125V,11A,Black,BSMI Current Engineer replace
04040888Power Cords Cable,Australia AC Power Cable,250V 10A,3.0m,PISM,H05VV-F-1.0mm^2(3C),C13SF,Black Current Engineer replace
04040889Power cord,BS546 250V10A,3.0m,PM-IAM,H05VV-F-1.5mm^2(3C),C13SF,250V,10A,Black Current Engineer replace
0405G019Power Cords Cable,Europe AC 250V10A,1.8m,C14SM,H05VV-F- 3*1.00^2,C13SF,PDU Cable Current Engineer replace
04050373Power cord,China AC Power Cable250V10A,1.0m,C14SM,(227IEC53(RVV)-1.0mm^2(3C)),C13SF,Black,PDU Cable Current Engineer replace
04041056Power cord,Europe AC Power Cable,250V10A,3.0m,PFSM,(H05VVF 1.0^2(3C)),C13SF,250V,10A,BLack Current Engineer replace
04050139Power Cords Cable,China AC Power Cable,250V10A,3m,PISM,227IEC53-1.0^2(3C),C13SF,Black Current Engineer replace
04150258Power Cable,Brazil AC Power Cable 250V10A,3.0m,PNSM ,H05VV-F-1.0mm^2(3C),C13SF,Black Current Engineer replace
04040887Power Cable,Japan AC Power Cable 125V12A,3.0m,PBSM,HVCTF-1.25mm^2(3C),C13SF,Black Current Engineer replace
14130923Optical Cable Parts,MPO/PC,MPO/PC,MULTI-MODE,15m,8 CORES,0m/0m,GJFH-8A1A.2(OM3),3.5MM,LSZH,60mm MPO,Bending insensitive Current Engineer replace
04050847Power cord,China AC Power Cable,250V10A,6.0m,C14SM,(227IEC53-1.0^2(3C)),C13SF,250V,10A,Black,PDU Cable Current Engineer replace
04051858Power cord,China AC Power Cable 250V10A,3.0m,PISM,227IEC53-1.0^2(3C),C13SF,250V,10A,Yellow Current Engineer replace
04041104Power Cords Cable,China AC Power 250V10A,3.0m,PISM,227IEC53-1.0^2(3C),C13SF,Black Current Engineer replace
04050846Power cord,China AC Power Cable,250V10A,3.0m,C14SM,(227IEC53-1.0^2(3C)),C13SF,250V,10A,Black,PDU Cable Current Engineer replace
04050206Power Cable,China AC Power Cable 250V10A,1.0m,PISM,227IEC53(RVV)1.0mm^2(3C),C13SF,Black Current Engineer replace
04040890Power Cable,Britain AC Power Cable 250V10A,3.0m,PGAM ,H05VV-F-1.0mm^2(3C),C13SF,Black Current Engineer replace
04051021High Speed Cable,Internal Mini SAS HD Cable,0.85m,Internal Mini SAS HD R/A,8*(1P*30AWG+ 2*Drain)+8C*30AWG,Internal Mini SAS HD STR,R/A-STR Current Engineer replace
0405Y020High Speed Cable,HS Cable Slimline-2*mini SAS HD,0.9m&0.8m,Slimline X8 STR,2*((31AWG*1Pair+31AWG*2Drain)*8+31AWG*1Pair*4),2*Internal mini SAS HD R/A,Slimline-2*mini SAS HD Current Engineer replace
0405Y011High Speed Cable,25G SFP28 Passive High Speed Cable,3m,SFP28,CC2P0.254B(S),SFP28 Current Engineer replace
04051074Power cord,India AC Power 250V 16A,3m,PM-IIIAM,IS 694-1.5mm^2(3C),C19SF,250V,16A,Black Current Engineer replace
0405Y010High Speed Cable,25G SFP28 Passive High Speed Cable,1m,SFP28,CC2P0.254B(S),SFP28 Current Engineer replace
04050422Power Cords Cable,China /Europe/America/Korea Multiple Certificate AC Power 250V16A,3.0m,C20SM,H05VV-F-1.5mm^2(3C) +14SJT3(3C),C19SF,PDU Cable Current Engineer replace
04051079Power cord,South Africa AC Power 250V16A,3m,PMAM,H05VV-F-1.5mm^2(3C),C19SF,250V,16A,Black Current Engineer replace
04152747Power Cable,1.8m,HVDC Straight Female,227IEC53(RVV)1.0mm^2(3C),C14SM Current Engineer replace
04051113IT Equipment Cable,Serial Port Cable,3m,D9 FM,CC2P0.32PWG1U,MP8-I Current Engineer replace
04052442High Speed Cable,200G HDR QSFP56 Passive Copper cable,1m,QSFP56,QSFP56,IB-Mellanox,LSZH Current Engineer replace
0405Y009High Speed Cable,10G Passive SFP+ Cable,5m,(SFP+20M),(CC2P0.4B),(SFP+20M),LSFRZH For Indoor,ETH 10GbE,Y Current Engineer replace
0405Y008High Speed Cable,10G Passive SFP+ Cable,1m,(SFP+20M),(CC2P0.254B),(SFP+20M),LSFRZH For Indoor,ETH 10GbE,LSZH Current Engineer replace
0405Y128Power cord,Japan AC Power 250V15A,3.0m,NEMA5-15PSM,HVCTF-2.0mm^2(3C)black,C19SF,125V,15A Current Engineer replace
0405Y007High Speed Cable,10G SFP+ High Speed Cable,3m,SFP+20M,CC2P0.254B(S),SFP+20M,LSFRZH For Indoor,ETH 10GbE,LSZH Current Engineer replace
04043396Power Cords Cable,China AC Power 250V16A,3.0m,PIAM,227IEC53-2.5^2(3C),C19SF,Black Current Engineer replace
0415Y642Power Cable,250V-16A 3m,2.5mm^2(3C),black,C21,2.5mm^2(3C),C20 Current Engineer replace
04045184Power Cords Cable,Australia AC Power 250V16A,3.0m,PISM,H05VVF-2.5^2(3C),C19SF,Black Current Engineer replace
04051418Power cord,China AC Power 250V16A,30.0m,PIAM,227IEC53-2.5^2(3C),C19SF,250V,16A,Black Current Engineer replace
04052139Power cord,Taiwan AC 125V15A,3.0m,PBSM,VCTFK3*2.0mm2(3C),C19SF,125V,15A,Black,BSMI Current Engineer replace
04050189Power Cords Cable,China AC Power 250V 16A,1.0m,C20SM,227IEC53x1.5^2(3C),C19SF,PDU Cable Current Engineer replace
04044598Power Cords Cable,Europe AC Power 250V16A,3.0m,PFAM,H05VVF-1.5^2(3C),C19SF,Black Current Engineer replace
04044597Power cord,BS546 250V16A,3.0m,PM-IAM,H05VV-F-1.5mm^2(3C),C19SF,250V,16A,Black Current Engineer replace
04050850Power Cords Cable,Britain AC Power Cable,250V13A,3.0m,PG AM,H05VV-F-1.5mm^2(3C),C19 SF,Black Current Engineer replace
04151188Power Cable,1.5m,HVDC Straight Female,227IEC53(RVV)1.0mm^2(3C) Current Engineer replace
04050856Power Cords Cable,Australia AC Power 250V16A,3.0m,C20SM,H05VV-F-1.5^2(3C),C19SF,PDU Power Cord Current Engineer replace
04150259Power Cords Cable,Brazil AC Power 250V16A,3.0m,PN-ISM ,H05VVF-1.5^2(3C),C19SF,Black Current Engineer replace
04050855Power Cords Cable,Japan AC Power 250V15A,3.0m,C20SM,VCTF-2.0^2(3C),C19SF,PDU Power Cord Current Engineer replace
04044603Power Cords Cable,North America AC Power 125V20A,3.0m,NEMA5-20PAM,12SJT(3C),C19SF,Black Current Engineer replace
04051322Power cord,Switzerland AC Power Cable,3m,PJ-II SM,H05VV-F-1.5mm^2(3C),C19SF,250V,16A Current Engineer replace
0405Y028High Speed Cable,HS Cable Slimline-2*mini SAS HD,0.8m&0.7m,Slimline X8 R/A,2*((31AWG*1Pair+31AWG*2Drain)*8+31AWG*1Pair*4),2*Internal mini SAS HD R/A,Slimline-2*mini SAS HD Current Engineer replace
0405Y040High Speed Cable,HS Cable Slimline-2*mini SAS HD,1.1m&1.0m,Slimline X8 STR,2*((31AWG*1Pair+31AWG*2Drain)*8+31AWG*1Pair*4),2*Internal mini SAS HD R/A,Slimline-2*mini SAS HD Current Engineer replace
0405Y021High Speed Cable,HS Cable Slimline-2*mini SAS HD,0.85m&0.75m,Slimline X8 STR,2*((31AWG*1Pair+31AWG*2Drain)*8+31AWG*1Pair*4),2*Internal mini SAS HD R/A,Slimline-2*mini SAS HD Current Engineer replace
0405Y019High Speed Cable,HS Cable Slimline-2*mini SAS HD,1.0m&0.9m,Slimline X8 STR,2*((31AWG*1Pair+31AWG*2Drain)*8+31AWG*1Pair*4),2*Internal mini SAS HD R/A,Slimline-2*mini SAS HD Current Engineer replace
04150441Power Cable,3.5m,4mm^2,2*T4^2GY,H07Z-K-4^2BL+H07Z-K-4^2B,2*T4^2GY,LSZH Current Engineer replace
04152464Power Cable,0.5m,4mm^2,(OT6-4),(H07Z-K-4^2G&Y),(OT6-6),LSZH,YES Current Engineer replace
0405Y047IT Equipment Cable,Signal Cable,0.65m,(H2X25(1.0)),(4*(1P*30AWG+1*Drain)+3* 30AWG Shield+4*(1P*30AWG)+22*UL1571 28AWG),(2*(H2X25(1.0))) Current Engineer replace
0405Y049High Speed Cable,Internal HS Cable,0.80m&0.70m,Slimline X8 STR,(31AWG*1Pair+32AWG*2Drain)*8+30AWG*1C*8,2*Internal Mini SAS HD R/A,Slimline-2*Mini SAS HD-Only for 1U Current Engineer replace
0405Y025High Speed Cable,HS Cable Slimline-2*mini SAS HD,0.8m&0.2m,Slimline X8 STR,2*((31AWG*1Pair+31AWG*2Drain)*8+31AWG*1Pair*4),Internal mini SAS HD R/A+STR,Slimline-2*mini SAS HD Current Engineer replace
0405Y121IT Equipment Cable,Signal Cable,0.65m,(H2X25(1.0)),(4*(1P*30AWG+1*Drain)+3* 30AWG Shield+4*(1P*30AWG)+22*UL1571 28AWG),(H2X25(1.0)) Current Engineer replace
14270055BTB Connector module,74,UBC 8X curved,150mm,0.16mm,10mm,32000MB/s,1.57mm,Wire mounting,Y Current Engineer replace
0405Y351High Speed Cable,Internal PCIe5.0 HS Cable,0.25m,MCIO X8 STR,(16*(1P*30AWG+2*Drain)+8*(1P*30AWG+1*Drain)+(4C*30AWG)),MCIO X8 STR Current Engineer replace
0405Y303High Speed Cable,HS Cable Slimline-2*MCIO X4,0.8m&0.7m,Slimline X8 STR,(2*(8*(1P*30AWG+2Drain)+4*(1P*30AWG+2Drain))),2*MCIO X4 STR,Slimline-2*MCIO X4 Current Engineer replace
0405Y018High Speed Cable,HS Cable Slimline-2*mini SAS HD,0.65m&0.55m,Slimline X8 STR,2*((31AWG*1Pair+31AWG*2Drain)*8+31AWG*1Pair*4),2*Internal mini SAS HD R/A,Slimline-2*mini SAS HD Current Engineer replace
0415Y648Power Cable,0.55&0.72m,Black,H2X6(3.0)+1X4(2.0),8*18UL1569B,2*(H2X4(3.0)+1X8(1.5)),Custom cables Current Engineer replace
0408Y217Monitor&Alarm Cable,Signal Cable,0.75m,H2X10(2.0),(8*28UL1685B)+2*28UL1685B(S),H2X10(1.0) Current Engineer replace
0408Y022Monitor&Alarm Cable,Signal cable,0.6m,H2X9(2.0),2*28UL1685B(S)+16*28UL1685B,H2X9(2.0),16/18 Pin Shielding Current Engineer replace
P/NDescription / SpecificationStatus
0231Y193Function Module,1288H V7,BC1M24FAN,4056+ Fan module Current Field replaceable
0231Y194Function Module,1288H V7,BC1M25FAN,4056++ Fan module Current Field replaceable
2116Y201Heatsink-2116Y201_DRAEN.ASM-1U body heatsink-118mm*78mm*25mm-Soldering-special heat sink Current Engineer replace
2116Y204Heatsink-2116Y204_DRAEN.ASM-1U inside the board remote hestsink-192mm*180mm*28.7mm-Soldering-special heat sink Current Engineer replace
2116Y202Heatsink-2116Y202_DRAEN.ASM-1U outside the board remote hestsink-233.5mm*185mm*35.9mm-Soldering-special heat sink Current Engineer replace

Operating System Compatibility

Operating SystemVersion / KernelRelease
RHEL 9.45.14.0-427.13.1.el9_4.x86_64Red Hat Enterprise Linux 9 Update 4 Server for Intel EM64T
RHEL 9.65.14.0-570.12.1.el9_6.x86_64Red Hat Enterprise Linux 9 Update 6 Server for Intel EM64T
RHEL 9.75.14.0-611.5.1.el9_7.x86_64Red Hat Enterprise Linux 9 Update 7 Server for Intel EM64T
RHEL 9.85.14.0-687.5.3.el9_8.x86_64Red Hat Enterprise Linux 9 Update 8 Server for Intel EM64T
Rocky Linux 9.65.14.0-570.17.1.el9_6.x86_64Rocky Linux 9 Update 6 Server for Intel EM64T
Rocky Linux 9.75.14.0-611.5.1.el9_7.x86_64Rocky Linux 9 Update 7 Server for Intel EM64T
Rocky Linux 9.85.14.0-687.10.1.el9_8.0.1.x86_64Rocky Linux 9 Update 8 Server for Intel EM64T
SLES 15 SP66.4.0-150600.21-defaultSUSE Linux Enterprise Server 15 Service Pack 6 for AMD64 & Intel64
Ubuntu 24.04 LTS6.8.0-31-genericUbuntu 24.04 LTS Server Edition for Intel EM64T
VMware ESXi 9.0build-24755229VMware ESXi 9.0 for Intel EM64T
VMware ESXi 9.1build-25370933VMware ESXi 9.1 for Intel EM64T
Windows Server 2022Build 20348Microsoft Windows Server 2022 x64
Windows Server 2025Build 26100Microsoft Windows Server 2025 x64
openEuler 24.03 LTS SP16.6.0-72.0.0.76.oe2403sp1.x86_64openEuler 24.03 LTS SP1 (powered by openEuler)

Configuring, expanding or replacing this server? Send us your part list or BOM for a fast quotation.

Request a Quote

Selecting components for the 1288 V8

These points from the matrix matter when configuring or expanding a unit:

  • Choose the processor to the workload. Validated options include from the 6505P to high-end options such as the 6787P, with up to 144 cores per socket.
  • Memory: DDR5 RDIMMs from 16GB to 96GB at up to 8800 MT/s. Give us your capacity target and we will confirm the supported DIMM population and channel rules.
  • RAID levels follow the controller. The validated controllers support RAID 0, 1, 5, 6, 10, 50, 60, JBOD. Cacheless entry cards suit boot and mirroring; cached cards with a supercapacitor enable parity RAID for data arrays; JBOD/IT cards provide passthrough to software RAID.
  • Storage mix. Validated options include SAS/SATA drives up to 20 TB and PCIe NVMe SSDs up to 15 TB. Backplane and tray variants are listed separately under Drive Backplanes.
  • Networking from 100GbE to 25GbE. OCP 3.0 and PCIe adapters are validated for the listed speeds; some SKUs include optical modules and others do not, so check the part description.
  • Power: 900–3000W supplies. Platinum and titanium-rated AC units are listed, with redundant pairs for high availability; confirm the rating your GPU and drive population require.

Reference workload profiles

These profiles show how validated components combine; each is configured and quoted to order.

  • Virtualization / private cloud: balanced processors, a large RDIMM footprint, hardware RAID with cache and redundant power.
  • Database / in-memory: high-frequency processors, maximum memory, PCIe NVMe for log and hot data.
  • All-flash node: parity-capable RAID or HBA, a full set of NVMe SSDs, high-wattage titanium PSU.
  • Storage / backup node: cached RAID or JBOD passthrough, a full set of high-capacity drives, high-wattage PSU.
  • General application / infra: mid-bin processors, moderate memory and storage, cost-effective networking.

The 1288 V8 in the FusionServer range

The numbered FusionServer generations make it straightforward to choose between current and supported hardware. The 1288 V8 is a V8 platform: Intel Xeon 6 (Granite Rapids / Sierra Forest), DDR5, PCIe 5.0.

Earlier supported generations remain useful:

  • V7: 4th/5th Generation Intel Xeon Scalable, DDR5, PCIe 4.0/5.0 — supported, cost-effective for standardised or budget projects.
  • V6: 3rd Generation Intel Xeon Scalable, DDR4, PCIe 4.0 — supported, cost-effective for standardised or budget projects.
  • V5: 1st/2nd Generation Intel Xeon Scalable, DDR4, PCIe 3.0 — supported, cost-effective for standardised or budget projects.

We supply new systems with manufacturer warranty and can source validated parts for earlier generations when a budget, software-licensing or support window calls for them. Ask us which generation fits.

1288 V8 — compatibility FAQ

Which processors does the 1288 V8 support?

The matrix lists from the 6505P to high-end options such as the 6787P, with up to 144 cores per socket. Confirm the thermal and power envelope for your chassis and PSU before ordering.

What memory can I install?

Validated DDR5 RDIMMs range from 16GB to 96GB at up to 8800 MT/s. Tell us your capacity target and we will confirm the supported DIMM population.

Which RAID levels are supported?

Validated controllers support RAID 0, 1, 5, 6, 10, 50, 60, JBOD. Choose a cached card with a supercapacitor for parity RAID (5/6/50/60), an entry card for 0/1/10, or an IT/JBOD card for software RAID passthrough.

What drives are validated?

The matrix lists SAS/SATA drives up to 20 TB and NVMe SSDs up to 15 TB. See the Hard Drives and NVMe tabs for the full list, form factors and current status.

What network speeds are supported?

Validated OCP and PCIe adapters cover 100GbE, 10GbE, 200GbE, 25GbE. Note whether a SKU includes optical modules; we can supply matched optics if required.

What power supplies are available?

The list runs from 900W to 3000W in platinum and titanium ratings. Redundant pairs can be configured for high availability; size the PSU to your CPU, GPU and drive load.

Which operating systems are certified?

The OS matrix lists 14 certified builds, including Red Hat Enterprise Linux, Rocky Linux, SUSE Linux Enterprise Server, Ubuntu, VMware ESXi, Windows Server, each with its exact kernel or build string. Additional builds can often be confirmed on request.

What do the lifecycle statuses mean?

Current/GA parts are in production; PILOT and DEVELOP parts are under limited rollout or qualification; EOM parts are out of marketing but supported as spares. Prefer Current parts for new builds.

Can you supply the server or just parts?

Both. We configure complete systems and supply every validated component listed here with warranty. Send a part list or BOM for a fast quotation.