The FusionServer Pro 2258 V7 is 2U dual-socket high-density server. It is a high-capacity 2U platform built around storage and expandability of this xFusion generation, designed for storage-dense virtualization and data workloads. The platform runs on 4th/5th Generation Intel Xeon Scalable with DDR5 memory and PCIe 4.0/5.0 expansion.

Below is the verified compatibility matrix for this model: 603 validated line items across 11 component categories and 55 certified operating-system builds, taken from xFusion’s official compatibility data and presented in English. Every part number listed is published by xFusion for this chassis; nothing is guessed or cross-filled from other models.

Form factor2u dual-socket high-density
Top core countUp to 128 cores / socket
Memory modulesDDR5 16–256GB
Memory speedUp to 6400 MT/s
Largest drive20 TB
NVMe capacityUp to 15 TB
Network speeds100GbE/10GbE/200GbE/25GbE
Power supplies900–3000W
Validated603 parts · 55 OS

Compatibility matrix

Browse validated parts by category using the tabs below. Each tab shows its item count; search inside a tab by part number or keyword, and expand the full list. Parts marked Current are actively orderable; life-cycle parts are still supported and often available as spares. The OS table lists the exact certified kernel or build.

P/NDescription / SpecificationStatus
4102Y077X86 series-OLGA6096-2400MHz-0.55V/1.5V-64bit-360000mW-AMD EPYC 9004 Series-Genoa 9654-96Core Current
4102Y078X86 series-OLGA6096-3100MHz-0.55V/1.5V-64bit-360000mW-AMD EPYC 9004 Series-Genoa 9554-64Core Current
4102Y079X86 series-OLGA6096-2750MHz-0.55V/1.5V-64bit-290000mW-AMD EPYC 9004 Series-Genoa 9454-48Core Current
4102Y080X86 series-OLGA6096-3250MHz-0.55V/1.5V-64bit-280000mW-AMD EPYC 9004 Series-Genoa 9354-32Core Current
4102Y081X86 series-OLGA6096-2900MHz-0.55V/1.5V-64bit-200000mW-AMD EPYC 9004 Series-Genoa 9254-24Core Current
4102Y083X86 series-OLGA6096-2450MHz-0.55V/1.5V-64bit-280000mW-AMD EPYC 9004 Series-Genoa 9534-64Core Current
4102Y084X86 series-OLGA6096-2700MHz-0.55V/1.5V-64bit-210000mW-AMD EPYC 9004 Series-Genoa 9334-32Core Current
4102Y085X86 series-OLGA6096-2500MHz-0.55V/1.5V-64bit-200000mW-AMD EPYC 9004 Series-Genoa 9224-24Core Current
4102Y086X86 series-OLGA6096-3000MHz-0.55V/1.5V-64bit-200000mW-AMD EPYC 9004 Series-Genoa 9124-16Core Current
4102Y087X86 series-OLGA6096-3600MHz-0.55V/1.5V-64bit-360000mW-AMD EPYC 9004 Series-Genoa 9474F-48Core Current
4102Y088X86 series-OLGA6096-3850MHz-0.55V/1.5V-64bit-320000mW-AMD EPYC 9004 Series-Genoa 9374F-32Core Current
4102Y089X86 series-OLGA6096-4050MHz-0.55V/1.5V-64bit-320000mW-AMD EPYC 9004 Series-Genoa 9274F-24Core Current
4102Y090X86 series-OLGA6096-4100MHz-0.55V/1.5V-64bit-320000mW-AMD EPYC 9004 Series-Genoa 9174F-16Core Current
4102Y105X86 series-OLGA6096-2250MHz-0.55V/1.5V-64bit-360000mW-AMD EPYC 9004 Series-Bergamo 9754-128Core Current
4102Y144X86 series-OLGA6096-2550MHz-0.55V/1.5V-64bit-400000mW-AMD EPYC 9004 Series-Genoa-X 9684X-96Core Current
4102Y184X86 series-OLGA6096-3100MHz-0.55V/1.5V-64bit-320000mW-AMD EPYC 9004 Series-Genoa-X 9384X-32Core Current
4102Y229X86 series-OLGA6096-2600MHz-0.55V/1.5V-64bit-400000mW-AMD EPYC 9004 Series-Genoa 9A14-96Core Current
90010339Liquid Manufactory Auxiliaries,Thermal Grease,X-23-7868-2D,Thermal Conductivity 3.6W/mK / 6.0W/mK,2g,Gap filling thermal conductive for customer use,1ml Current
4102Y185X86 series,OLGA6096,3400MHz,0.55V/1.5V,64bit,400000mW,AMD EPYC 9004 Series-Genoa 9A84-64Core Current Field replaceable
P/NDescription / SpecificationStatus
0251Y062memory module-2288H V7-generic memory-DDR5-RDIMM-64GB-288pin-0.42ns-4800000KHz-1.1V-ECC-2Rank(4G*4bit)-overseas dedicated Current
0251Y064memory module-2288H V7-generic memory-DDR5-RDIMM-16GB-288pin-0.42ns-4800000KHz-1.1V-ECC-1Rank(2G*8bit)-overseas dedicated Current
0251Y112memory module-2288H V7-generic memory-DDR5-RDIMM-64GB-288pin-0.42ns-4800000KHz-1.1V-ECC-2Rank(4G*4bit) Current
0251Y143memory module-2258 V7-generic memory-DDR5-RDIMM-32GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(2G*8bit)-3-way OEM code_overseas dedicated Current
0251Y144memory module-2258 V7-generic memory-DDR5-RDIMM-64GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(4G*4bit)-3-way OEM code_overseas dedicated Current
0251Y145memory module-2258 V7-generic memory-DDR5-RDIMM-96GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(6G*4bit)-3-way OEM code_overseas dedicated Current
0251Y150memory module-2288H V7-generic memory-DDR5-RDIMM-16GB-288pin-0.357ns-5600000KHz-1.1V-ECC-1Rank(2G*8bit)-overseas dedicated Current
0251Y177memory module-2258 V7-generic memory-DDR5-RDIMM-64GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(4G*4bit)-XH-overseas dedicated Current
0251Y195memory module-2258 V7-generic memory-DDR5-RDIMM-64GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(4G*4bit)-SK hynix Current
0251Y197memory module-2288H V7-generic memory-DDR5-RDIMM-32GB-288pin-0.42ns-4800000KHz-1.1V-ECC-2Rank(2G*8bit)-overseas dedicated-spec code Current
0251Y198memory module-2288H V7-generic memory-DDR5-RDIMM-16GB-288pin-0.42ns-4800000KHz-1.1V-ECC-1Rank(2G*8bit)-overseas dedicated-spec code Current
0251Y202memory module-2288H V7-generic memory-DDR5-RDIMM-32GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(2G*8bit)-overseas dedicated-spec code Current
0251Y203memory module-2288H V7-generic memory-DDR5-RDIMM-64GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(4G*4bit)-overseas dedicated-spec code Current
0251Y226memory module-2288H V7-generic memory-DDR5-RDIMM-128GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(8G*4bit)-SDP-overseas dedicated Current
0251Y273memory module-2288H V7-generic memory-DDR5-RDIMM-64GB-288pin-0.312ns-6400000KHz-1.1V-ECC-2Rank(4G*4bit) Current
0251Y276memory module-2288H V7-generic memory-DDR5-RDIMM-16GB-288pin-0.357ns-5600000KHz-1.1V-ECC-1Rank(2G*8bit) Current
0251Y287memory module-2288H V7-M564R32-generic memory-DDR5-RDIMM-32GB-288pin-0.312ns-6400000KHz-1.1V-ECC-2Rank(2G*8bit)-overseas dedicated Current
0251Y288memory module-2288H V7-M564R64-generic memory-DDR5-RDIMM-64GB-288pin-0.312ns-6400000KHz-1.1V-ECC-2Rank(4G*4bit)-overseas dedicated Current
0251Y289memory module-2288H V7-M564R96-generic memory-DDR5-RDIMM-96GB-288pin-0.312ns-6400000KHz-1.1V-ECC-2Rank(6G*4bit)-3-way OEM code_overseas dedicated Current
0251Y290memory module-2288H V7-M564R128-generic memory-DDR5-RDIMM-128GB-288pin-0.312ns-6400000KHz-1.1V-ECC-2Rank(8G*4bit)-3-way OEM code_overseas dedicated Current
0251Y291memory module-2288H V7-M556R64-generic memory-DDR5-RDIMM-64GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(4G*4bit)-for use in China only Current
0251Y297memory module-2288H V7-M564R32-generic memory-DDR5-RDIMM-32GB-288pin-0.312ns-6400000KHz-1.1V-ECC-2Rank(2G*8bit)-Samsung 1bnm-Turin platform prohibited Current
0251Y304memory module-2288 V8-M556R64-generic memory-DDR5-RDIMM-64GB-288pin-0.312ns-6400000KHz-1.1V-ECC-2Rank(4G*4bit)-XH consumable virtual code-overseas dedicated Current
0251Y307memory module-2258 V7-M556R96-generic memory-DDR5-RDIMM-96GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(6G*4bit)-XH consumable virtual code-overseas dedicated Current
0251Y314memory module-M556R32-DDR5 RDIMM-32GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(2G*8bit) Current
0251Y315memory module-2288H V7-M564R32-generic memory-DDR5-RDIMM-32GB-288pin-0.312ns-6400000KHz-1.1V-ECC-2Rank(2G*8bit)-Samsung 1bnm-Turin platform prohibited Current
0251Y316memory module-2258 V7-M556R64-generic memory-DDR5-RDIMM-64GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(4G*4bit)-CXMT G4-down-binned die Current
0251Y317memory module-2288H V7-generic memory-DDR5-RDIMM-64GB-288pin-0.312ns-6400000KHz-1.1V-ECC-2Rank(4G*4bit) Current
0251Y321memory module-2288H V7-generic memory-DDR5-RDIMM-64GB-288pin-0.312ns-6400000KHz-1.1V-ECC-2Rank(4G*4bit) Current
0251Y325memory module-2288H V7-M564R32-generic memory-DDR5-RDIMM-32GB-288pin-0.312ns-6400000KHz-1.1V-ECC-2Rank(2G*8bit)-Samsung 1bnm-Turin platform prohibited Current
0251Y326memory module-DDR5 RDIMM-64GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(4G*4bit) Current
0251Y344memory module-2258 V7-M564R64-generic memory-DDR5-RDIMM-64GB-288pin-0.312ns-6400000KHz-1.1V-ECC-2Rank(4G*4bit)-Samsung 1bnm-Turin platform prohibited Current
0251Y347memory module-2258 V7-M556R64-generic memory-DDR5-RDIMM-64GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(4G*4bit)-Haipu_XH Current
06200484generic memory-DDR5-RDIMM-64GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(4G*4bit)-HYNIX 1anm Current
0620Y006-006generic memory-DDR5-RDIMM-64GB-288pin-0.42ns-4800000KHz-1.1V-ECC-2Rank(4G*4bit)-3-way OEM code Current
0620Y006-020generic memory-DDR5-RDIMM-64GB-288pin-0.42ns-4800000KHz-1.1V-ECC-2Rank(4G*4bit)-designated-model dedicated-SAMSUNG 1ynm Current
0620Y006-024generic memory-DDR5-RDIMM-64GB-288pin-0.42ns-4800000KHz-1.1V-ECC-2Rank(4G*4bit)-designated model HMCG94AEBRA109N-Hynix 1anm Current
0620Y006-B03generic memory-DDR5-RDIMM-64GB-288pin-0.42ns-4800000KHz-1.1V-ECC-2Rank(4G*4bit)-Hynix 1ynm-M die Current
0620Y010-003generic memory-DDR5-RDIMM-256GB-288pin-0.42ns-4800000KHz-1.1V-ECC-8Rank(8G*4bit)-3DS Current
0620Y019generic memory-DDR5-RDIMM-48GB-288pin-0.416ns-4800000KHz-1.1V-ECC-2Rank(3G*8bit) Current
0620Y026generic memory-DDR5-RDIMM-96GB-288pin-0.416ns-4800000KHz-1.1V-ECC-2Rank(6G*4bit) Current
0620Y026-012generic memory-DDR5-RDIMM-96GB-288pin-0.416ns-4800000KHz-1.1V-ECC-2Rank(6G*4bit)-designated-model dedicated-SAMSUNG 1anm Current
0620Y026-B03generic memory-DDR5-RDIMM-96GB-288pin-0.416ns-4800000KHz-1.1V-ECC-2Rank(6G*4bit)-Micron 1anm Current
0620Y027generic memory-DDR5-RDIMM-16GB-288pin-0.357ns-5600000KHz-1.1V-ECC-1Rank(2G*8bit) Current
0620Y027-002generic memory-DDR5-RDIMM-16GB-288pin-0.357ns-5600000KHz-1.1V-ECC-1Rank(2G*8bit)-designated-model dedicated-HYNIX 1anm Current
0620Y027-003generic memory-DDR5-RDIMM-16GB-288pin-0.357ns-5600000KHz-1.1V-ECC-1Rank(2G*8bit)-3-way OEM code_overseas dedicated Current
0620Y029generic memory-DDR5-RDIMM-32GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(2G*8bit) Current
0620Y029-001generic memory-DDR5-RDIMM-32GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(2G*8bit)-SK Hynix 1anm-designated-model dedicated Current
0620Y029-020generic memory-DDR5-RDIMM-32GB-288pin-0.312ns-6400000KHz-1.1V-ECC-2Rank(2G*8bit)-Samsung 1bnm-Turin platform prohibited Current
0620Y029-023generic memory-DDR5-RDIMM-32GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(2G*8bit)-Haipu Current
0620Y029-024generic memory-DDR5-RDIMM-32GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(2G*8bit)-Tigo/kingbank Current
0620Y030generic memory-DDR5-RDIMM-48GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(3G*8bit) Current
0620Y031generic memory-DDR5-RDIMM-64GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(4G*4bit) Current
0620Y031-004generic memory-DDR5-RDIMM-64GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(4G*4bit)-SK Hynix 1anm Current
0620Y031-006generic memory-DDR5-RDIMM-64GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(4G*4bit)-XH consumable virtual code Current
0620Y031-009generic memory-DDR5-RDIMM-64GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(4G*4bit)-Xiaohongshu designated-Hynix 1anm Current
0620Y031-010generic memory-DDR5-RDIMM-64GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(4G*4bit)-internet designated-SK Hynix 1anm Current
0620Y031-012generic memory-DDR5-RDIMM-64GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(4G*4bit)-CXMT G4 Current
0620Y031-024generic memory-DDR5-RDIMM-64GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(4G*4bit)-XH consumable virtual code-for use in China Current
0620Y031-025generic memory-DDR5-RDIMM-64GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(4G*4bit)-CXMT G4-down-binned die Current
0620Y031-026generic memory-DDR5-RDIMM-64GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(4G*4bit)-CXMT G4-designated model CXMR4E464R8AS-CB1C Current
0620Y031-027generic memory-DDR5-RDIMM-64GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(4G*4bit)-Haipu Current
0620Y031-028generic memory-DDR5-RDIMM-64GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(4G*4bit)-Tigo/kingbank Current
0620Y031-029generic memory-DDR5-RDIMM-64GB-288pin-0.312ns-6400000KHz-1.1V-ECC-2Rank(4G*4bit)-Samsung 1bnm-Turin platform prohibited Current
0620Y032generic memory-DDR5-RDIMM-96GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(6G*4bit) Current
0620Y032-001generic memory-DDR5-RDIMM-96GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(6G*4bit)-SAMSUNG 1anm Current
0620Y032-006generic memory-DDR5-RDIMM-96GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(6G*4bit)-3-way OEM code_overseas dedicated Current
0620Y032-009generic memory-DDR5-RDIMM-96GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(6G*4bit)-designated-model dedicated-longsys Current
0620Y032-012generic memory-DDR5-RDIMM-96GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(6G*4bit)-Haipu Current
0620Y035generic memory-DDR5-RDIMM-128GB-288pin-0.312ns-6400000KHz-1.1V-ECC-2Rank(8G*4bit) Current
0620Y038generic memory-DDR5-RDIMM-16GB-288pin-0.312ns-6400000KHz-1.1V-ECC-1Rank(2G*8bit) Current
0620Y040generic memory-DDR5-RDIMM-32GB-288pin-0.312ns-6400000KHz-1.1V-ECC-2Rank(2G*8bit) Current
0620Y042generic memory-DDR5-RDIMM-64GB-288pin-0.312ns-6400000KHz-1.1V-ECC-2Rank(4G*4bit) Current
0620Y042-006generic memory-DDR5-RDIMM-64GB-288pin-0.312ns-6400000KHz-1.1V-ECC-2Rank(4G*4bit)-overseas dedicated Current
0620Y042-011generic memory-DDR5-RDIMM-64GB-288pin-0.312ns-6400000KHz-1.1V-ECC-2Rank(4G*4bit)-CXMT Current
0620Y043generic memory-DDR5-RDIMM-96GB-288pin-0.312ns-6400000KHz-1.1V-ECC-2Rank(6G*4bit) Current
0620Y043-011generic memory-DDR5-RDIMM-96GB-288pin-0.312ns-6400000KHz-1.1V-ECC-2Rank(6G*4bit)-CXMT Current
0620Y044generic memory-DDR5-RDIMM-256GB-288pin-0.312ns-6400000KHz-1.1V-ECC-4Rank(8G*4bit)-3DS Current
0620Y044-002generic memory-DDR5-RDIMM-256GB-288pin-0.312ns-6400000KHz-1.1V-ECC-8Rank(8G*4bit)-3DS-XH consumable virtual code Current
0620Y044-A01generic memory-DDR5-RDIMM-256GB-288pin-0.312ns-6400000KHz-1.1V-ECC-4Rank(8G*4bit)-3DS Samsung_DBS Current
0620Y061generic memory-DDR5-RDIMM-128GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(8G*4bit)-SDP Current
0620Y061-A03generic memory-DDR5-RDIMM-128GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(8G*4bit)-SDP-Samsung MB0_DBS Current
0620Y068generic memory-DDR5-RDIMM-16GB-288pin-0.42ns-4800000KHz-1.1V-ECC-1Rank(2G*8bit)-spec code Current
0620Y069generic memory-DDR5-RDIMM-32GB-288pin-0.42ns-4800000KHz-1.1V-ECC-2Rank(2G*8bit)-spec code Current
0620Y070generic memory-DDR5-RDIMM-64GB-288pin-0.42ns-4800000KHz-1.1V-ECC-2Rank(4G*4bit)-spec code Current
0620Y071generic memory-DDR5-RDIMM-32GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(2G*8bit)-spec code Current
0620Y072generic memory-DDR5-RDIMM-64GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(4G*4bit)-spec code Current
0251Y063memory module-2288H V7-generic memory-DDR5-RDIMM-32GB-288pin-0.42ns-4800000KHz-1.1V-ECC-2Rank(2G*8bit)-overseas dedicated EOM
0251Y110memory module-2288H V7-generic memory-DDR5 RDIMM-16GB-288pin-0.42ns-4800000KHz-1.1V-ECC-1Rank(2G*8bit) EOP
0251Y111memory module-2288H V7-generic memory-DDR5-RDIMM-32GB-288pin-0.42ns-4800000KHz-1.1V-ECC-2Rank(2G*8bit) EOP
0251Y123memory module-2288H V7-generic memory-DDR5-RDIMM-16GB-288pin-0.42ns-4800000KHz-1.1V-ECC-1Rank(2G*8bit) EOS
0251Y124memory module-2288H V7-generic memory-DDR5-RDIMM-32GB-288pin-0.42ns-4800000KHz-1.1V-ECC-2Rank(2G*8bit) EOS
0251Y125memory module-2288H V7-generic memory-DDR5-RDIMM-64GB-288pin-0.42ns-4800000KHz-1.1V-ECC-2Rank(4G*4bit) EOS
0251Y126memory module-2288H V7-generic memory-DDR5-RDIMM-128GB-288pin-0.42ns-4800000KHz-1.1V-ECC-4Rank(4G*4bit)-3DS EOS
0251Y129memory module-2288H V7-generic memory-DDR5-RDIMM-128GB-288pin-0.42ns-4800000KHz-1.1V-ECC-4Rank(4G*4bit)-3DS-domestic&overseas general EOP
0251Y146memory module-2288H V7-generic memory-DDR5-RDIMM-16GB-288pin-0.42ns-4800000KHz-1.1V-ECC-1Rank(2G*8bit)-0620Y003-XH-JWY SAMSUNG 1ynm EOM
0251Y174memory module-2288H V7-generic memory-DDR5-RDIMM-64GB-288pin-0.42ns-4800000KHz-1.1V-ECC-2Rank(4G*4bit)-XH EOM
0620Y003generic memory-DDR5-RDIMM-16GB-288pin-0.42ns-4800000KHz-1.1V-ECC-1Rank(2G*8bit) EOM
0620Y003-001generic memory-DDR5-RDIMM-16GB-288pin-0.42ns-4800000KHz-1.1V-ECC-1Rank(2G*8bit)-designated-model dedicated-Samsung 1ynm EOM
0620Y003-002generic memory-DDR5-RDIMM-16GB-288pin-0.42ns-4800000KHz-1.1V-ECC-1Rank(2G*8bit)-designated-model dedicated-Hynix 1anm EOM
0620Y003-003generic memory-DDR5-RDIMM-16GB-288pin-0.42ns-4800000KHz-1.1V-ECC-1Rank(2G*8bit)-3-way OEM code EOM
0620Y005generic memory-DDR5-RDIMM-32GB-288pin-0.42ns-4800000KHz-1.1V-ECC-2Rank(2G*8bit) EOM
0620Y005-001generic memory-DDR5-RDIMM-32GB-288pin-0.42ns-4800000KHz-1.1V-ECC-2Rank(2G*8bit)-designated-model dedicated-Samsung 1ynm EOM
0620Y005-002generic memory-DDR5-RDIMM-32GB-288pin-0.42ns-4800000KHz-1.1V-ECC-2Rank(2G*8bit)-designated-model dedicated-Hynix 1anm EOM
0620Y005-003generic memory-DDR5-RDIMM-32GB-288pin-0.42ns-4800000KHz-1.1V-ECC-2Rank(2G*8bit)-3-way OEM code EOM
0620Y006generic memory-DDR5-RDIMM-64GB-288pin-0.42ns-4800000KHz-1.1V-ECC-2Rank(4G*4bit) EOM
0620Y006-001generic memory-DDR5-RDIMM-64GB-288pin-0.42ns-4800000KHz-1.1V-ECC-2Rank(4G*4bit)-designated-model dedicated-Samsung 1ynm EOM
0620Y006-002generic memory-DDR5-RDIMM-64GB-288pin-0.42ns-4800000KHz-1.1V-ECC-2Rank(4G*4bit)-designated-model dedicated-Hynix 1anm EOM
0620Y009generic memory-DDR5-RDIMM-128GB-288pin-0.42ns-4800000KHz-1.1V-ECC-4Rank(4G*4bit)-3DS EOM
0620Y010generic memory-DDR5-RDIMM-256GB-288pin-0.42ns-4800000KHz-1.1V-ECC-8Rank(8G*4bit)-3DS EOM
0620Y026-003generic memory-DDR5-RDIMM-96GB-288pin-0.416ns-4800000KHz-1.1V-ECC-2Rank(6G*4bit)-designated-model dedicated-Hynix 1anm EOM
0620Y026-010generic memory-DDR5-RDIMM-96GB-288pin-0.416ns-4800000KHz-1.1V-ECC-2Rank(6G*4bit)-designated-model dedicated-SAMSUNG 1anm EOM
0620Y026-B02generic memory-DDR5-RDIMM-96GB-288pin-0.416ns-4800000KHz-1.1V-ECC-2Rank(6G*4bit)-Hynix 1anm EOM
0620Y027-001generic memory-DDR5-RDIMM-16GB-288pin-0.357ns-5600000KHz-1.1V-ECC-1Rank(2G*8bit)-designated-model dedicated-Samsung 1anm EOM
0620Y029-002generic memory-DDR5-RDIMM-32GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(2G*8bit)-designated-model dedicated-Samsung 1anm EOM
0620Y031-003generic memory-DDR5-RDIMM-64GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(4G*4bit)-SAMSUNG 1anm EOM
0620Y031-021generic memory-DDR5-RDIMM-64GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(4G*4bit)-SAMSUNG-customer designated EOM
0620Y031-022generic memory-DDR5-RDIMM-64GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(4G*4bit)-customer designated-SAMSUNG 1bnm EOM
0251Y351General Memory Module,2258 V7,M556R64,Memory Module,DDR5-RDIMM,64GB,288pin,0.357ns,5600000KHz,1.1V,ECC,2Rank(4G*4bit),Samsung 1anm_Appointed_XH Current Field replaceable
0251Y350General Memory Module,2258 V7,M556R64,Memory Module,DDR5-RDIMM,64GB,288pin,0.357ns,5600000KHz,1.1V,ECC,2Rank(4G*4bit),Hynix 1anm_Appointed_XH Current Field replaceable
P/NDescription / SpecificationStatus
0254Y057generic drive module-Servers-generic drive-600GB-SAS 12Gb/s-10000rpm-2.5inch-128MB and above-hot-swap-internal-2.5 inch bracket-V7 server dedicated Current
0254Y058generic drive module-Servers-generic drive-600GB-SAS 12Gb/s-10000rpm-2.5inch-128MB and above-hot-swap-internal-3.5 inch bracket-V7 server dedicated Current
0254Y059generic drive module-Servers-generic drive-1200GB-SAS 12Gb/s-10000rpm-2.5inch-128MB and above-hot-swap-internal-2.5 inch bracket-V7 server dedicated Current
0254Y060generic drive module-Servers-generic drive-1200GB-SAS 12Gb/s-10000rpm-2.5inch-128MB and above-hot-swap-internal-3.5 inch bracket-V7 server dedicated Current
0254Y061generic drive module-Servers-generic drive-1800GB-SAS 12Gb/s-10000rpm-2.5inch-128MB-hot-swap-internal-2.5 inch bracket-V7 server dedicated Current
0254Y062generic drive module-Servers-generic drive-1800GB-SAS 12Gb/s-10000rpm-2.5inch-128MB-hot-swap-internal-3.5 inch bracket-V7 server dedicated Current
0254Y063generic drive module-Servers-generic drive-2400GB-SAS 12Gb/s-10000rpm-2.5inch-256MB-hot-swap-internal-2.5 inch bracket-V7 server dedicated Current
0254Y064generic drive module-Servers-generic drive-2400GB-SAS 12Gb/s-10000rpm-2.5inch-256MB-hot-swap-internal-3.5 inch bracket-V7 server dedicated Current
0254Y065generic drive module-Servers-generic drive-4000GB-SATA 6.0Gb/s-7.2K rpm-3.5inch-128MB or above-hot-swap-internal-3.5 inch bracket-V7 server dedicated Current
0254Y069generic drive module-Servers-generic drive-12TB-SATA 6.0Gb/s-7.2K rpm-3.5inch-256MB-hot-swap-internal-3.5 inch bracket-V7 server dedicated Current
0254Y071generic drive module-Servers-generic drive-16TB-SATA 6.0Gb/s-7.2K rpm-3.5 inch-hot-swap-internal-3.5 inch bracket-V7 server dedicated Current
0254Y096generic drive module-Servers-generic drive-20TB-SATA 6.0Gb/s-7.2K rpm-3.5 inch-hot-swap-internal-3.5 inch bracket-V7 server dedicated Current
0254Y356generic drive module-Servers-generic drive-2400GB-SAS 12Gb/s-10000rpm-2.5inch-256MB and above-hot-swap-internal-2.5 inch bracket-V7 server dedicated-Seagate dedicated Current
0254Y357generic drive module-Servers-generic drive-2400GB-SAS 12Gb/s-10000rpm-2.5inch-256MB-hot-swap-internal-3.5 inch bracket-V7 server dedicated-Seagate dedicated Current
0254Y358generic drive module-Servers-generic drive-2400GB-SAS 12Gb/s-10000rpm-2.5inch-128MB-hot-swap-internal-2.5 inch bracket-V7 server dedicated-Toshiba dedicated Current
0254Y359generic drive module-Servers-generic drive-2400GB-SAS 12Gb/s-10000rpm-2.5inch-256MB-hot-swap-internal-3.5 inch bracket-V7 server dedicated-Toshiba dedicated Current
0254Y369generic drive module-Servers-generic drive-600GB-SAS 12Gb/s-10000rpm-2.5inch-128MB and above-hot-swap-internal-2.5 inch bracket-V7 server dedicated-Seagate dedicated Current
0254Y370generic drive module-Servers-generic drive-600GB-SAS 12Gb/s-10000rpm-2.5inch-128MB and above-hot-swap-internal-2.5 inch bracket-V7 server dedicated-Toshiba dedicated Current
0254Y442generic drive module-Servers-generic drive-20TB-SATA 6.0Gb/s-7.2K rpm-3.5 inch-hot-swap-internal-3.5 inch bracket-V7 dedicated-Toshiba-customer designated Current
0254Y470generic drive module-Servers-generic drive-8000GB-SATA 6.0Gb/s-7.2K rpm-3.5inch-128MB or above-hot-swap-internal-3.5 inch bracket-SEAGATE-V7 dedicated Current
0254Y496generic drive module-Servers-generic drive-8000GB-SATA 6.0Gb/s-7.2K rpm-3.5inch-128MB or above-hot-swap-internal-3.5 inch bracket-WD-V7 dedicated Current
0254Y512generic drive module-Servers-generic drive-4000GB-SATA 6.0Gb/s-7.2K rpm-3.5inch-128MB or above-hot-swap-internal-3.5 inch bracket-V7 dedicated-spec code Current
0254Y514generic drive module-Servers-generic drive-8000GB-SATA 6.0Gb/s-7.2K rpm-3.5inch-128MB or above-hot-swap-internal-3.5 inch bracket-V7 dedicated-spec code Current
0254Y516generic drive module-Servers-generic drive-12TB-SATA 6.0Gb/s-7.2K rpm-3.5inch-256MB-hot-swap-internal-3.5 inch bracket-V7 dedicated-spec code Current
0254Y518generic drive module-Servers-generic drive-16TB-SATA 6.0Gb/s-7.2K rpm-3.5inch-hot-swap-internal-3.5 inch bracket-V7 dedicated-spec code Current
0254Y520generic drive module-Servers-generic drive-18TB-SATA 6.0Gb/s-7.2K rpm-3.5inch-hot-swap-internal-3.5 inch bracket-V7 dedicated-spec code Current
0254Y522generic drive module-Servers-generic drive-20TB-SATA 6.0Gb/s-7.2K rpm-3.5inch-hot-swap-internal-3.5 inch bracket-V7 dedicated-spec code Current
0254Y533generic drive module-Servers-generic drive-600GB-SAS 12Gb/s-10000rpm-2.5inch-128MB and above-hot-swap-internal-2.5 inch bracket-V7 dedicated-spec code Current
0254Y539generic drive module-Servers-generic drive-2400GB-SAS 12Gb/s-10000rpm-2.5inch-256MB-hot-swap-internal-2.5 inch bracket-V7 dedicated-spec code Current
0254Y540generic drive module-Servers-generic drive-2400GB-SAS 12Gb/s-10000rpm-2.5inch-256MB-hot-swap-internal-3.5 inch bracket-V7 dedicated-spec code Current
0254Y691generic drive module-Servers-generic drive-20TB-SATA 6.0Gb/s-7.2K rpm-3.5 inch-hot-swap-internal-3.5 inch bracket-designated-model dedicated-Summit V7 server dedicated Current
0254Y693generic drive module-Servers-generic drive-16000GB-SATA 6.0Gb/s-7.2K rpm-3.5inch-256MB-hot-swap-internal-3.5 inch bracket-designated-model dedicated-Summit V7 server dedicated Current
0254Y696generic drive module-Servers-generic drive-4000GB-SATA 6.0Gb/s-7.2K rpm-3.5inch-128MB or above-hot-swap-internal-3.5 inch bracket-Seagate V7 server dedicated Current
0254Y697generic drive module-Servers-generic drive-4000GB-SATA 6.0Gb/s-7.2K rpm-3.5inch-128MB or above-hot-swap-internal-3.5 inch bracket-WD V7 server dedicated Current
0254Y702generic drive module-Servers-generic drive-600GB-SAS 12Gb/s-10000rpm-2.5inch-128MB and above-hot-swap-internal-3.5 inch bracket-V7 server dedicated-Toshiba dedicated Current
0254Y704generic drive module-Servers-generic drive-1200GB-SAS 12Gb/s-10000rpm-2.5inch-128MB and above-hot-swap-internal-2.5 inch bracket-V7 dedicated-spec code Current
0254Y706generic drive module-Servers-generic drive-1800GB-SAS 12Gb/s-10000rpm-2.5inch-128MB and above-hot-swap-internal-2.5 inch bracket-V7 dedicated-spec code Current
0254Y707generic drive module-Servers-generic drive-1800GB-SAS 12Gb/s-10000rpm-2.5inch-128MB and above-hot-swap-internal-3.5 inch bracket-V7 dedicated-spec code Current
0254Y709generic drive module-Servers-generic drive-1200GB-SAS 12Gb/s-10000rpm-2.5inch-128MB and above-hot-swap-internal-3.5 inch bracket-V7 server dedicated-Toshiba dedicated Current
0254Y710generic drive module-Servers-generic drive-1200GB-SAS 12Gb/s-10000rpm-2.5inch-128MB and above-hot-swap-internal-2.5 inch bracket-V7 server dedicated-Seagate dedicated Current
0254Y711generic drive module-Servers-generic drive-1200GB-SAS 12Gb/s-10000rpm-2.5inch-128MB and above-hot-swap-internal-2.5 inch bracket-V7 server dedicated-Toshiba dedicated Current
0254Y712generic drive module-Servers-generic drive-1800GB-SAS 12Gb/s-10000rpm-2.5inch-128MB and above-hot-swap-internal-3.5 inch bracket-V7 server dedicated-Seagate dedicated Current
0254Y713generic drive module-Servers-generic drive-1800GB-SAS 12Gb/s-10000rpm-2.5inch-128MB and above-hot-swap-internal-3.5 inch bracket-V7 server dedicated-Toshiba dedicated Current
0254Y714generic drive module-Servers-generic drive-1800GB-SAS 12Gb/s-10000rpm-2.5inch-128MB and above-hot-swap-internal-2.5 inch bracket-V7 server dedicated-Seagate dedicated Current
0254Y715generic drive module-Servers-generic drive-1800GB-SAS 12Gb/s-10000rpm-2.5inch-128MB and above-hot-swap-internal-2.5 inch bracket-V7 server dedicated-Toshiba dedicated Current
0254Y888generic drive module-Servers-generic drive-20000GB-NL SAS 12Gb/s-7200rpm-3.5inch-256MB-hot-swap-internal-3.5 inch bracket-Seagate Summit V7 server dedicated Current
0254Y948generic drive module-Servers-generic drive-12000GB-NL SAS 12Gb/s-7200rpm-3.5inch-256MB-hot-swap-internal-3.5 inch bracket-Paris-CP V7 server dedicated Current
0254Y949generic drive module-Servers-generic drive-16000GB-NL SAS 12.0Gb/s-7200rpm-3.5inch-256MB-hot-swap-internal-3.5 inch bracket-Paris-CP V7 dedicated Current
0254Y950generic drive module-Servers-generic drive-20000GB-NL SAS 12Gb/s-7200rpm-3.5inch-256MB-hot-swap-internal-3.5 inch bracket-Paris-CP V7 server dedicated Current
0255Y347SSD module-Servers-SSD-1920GB-SATA 6Gb/s-mixed read-write-PM897 series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255Y417SSD module-Servers-SSD-480GB-SATA 6Gb/s-read-intensive-PM893 series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255Y418SSD module-Servers-SSD-480GB-SATA 6Gb/s-read-intensive-PM893 series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255Y419SSD module-Servers-SSD-960GB-SATA 6Gb/s-read-intensive-PM893 series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255Y420SSD module-Servers-SSD-960GB-SATA 6Gb/s-read-intensive-PM893 series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255Y421SSD module-Servers-SSD-1920GB-SATA 6Gb/s-read-intensive-PM893 series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255Y422SSD module-Servers-SSD-1920GB-SATA 6Gb/s-read-intensive-PM893 series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255Y423SSD module-Servers-SSD-3840GB-SATA 6Gb/s-read-intensive-PM893 series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255Y424SSD module-Servers-SSD-3840GB-SATA 6Gb/s-read-intensive-PM893 series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255Y427SSD module-Servers-SSD-480GB-SATA 6Gb/s-mixed read-write-PM897 series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255Y428SSD module-Servers-SSD-480GB-SATA 6Gb/s-mixed read-write-PM897 series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255Y429SSD module-Servers-SSD-960GB-SATA 6Gb/s-mixed read-write-PM897 series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255Y430SSD module-Servers-SSD-960GB-SATA 6Gb/s-mixed read-write-PM897 series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255Y431SSD module-Servers-SSD-1920GB-SATA 6Gb/s-mixed read-write-PM897 series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255Y432SSD module-Servers-SSD-3840GB-SATA 6Gb/s-mixed read-write-PM897 series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255Y433SSD module-Servers-SSD-3840GB-SATA 6Gb/s-mixed read-write-PM897 series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255YACTSSD module-Servers-SSD-480GB-SATA 6Gb/s-mixed read-write-PM897a series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255YACUSSD module-Servers-SSD-480GB-SATA 6Gb/s-mixed read-write-PM897a series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255YACWSSD module-Servers-SSD-1920GB-SATA 6Gb/s-mixed read-write-PM897a series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255YACXSSD module-Servers-SSD-1920GB-SATA 6Gb/s-mixed read-write-PM897a series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255YACYSSD module-Servers-SSD-960GB-SATA 6Gb/s-mixed read-write-PM897a series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255YADASSD module-Servers-SSD-960GB-SATA 6Gb/s-mixed read-write-PM897a series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255YADBSSD module-Servers-SSD-3840GB-SATA 6Gb/s-mixed read-write-PM897a series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255YADHSSD module-Servers-SSD-3840GB-SATA 6Gb/s-mixed read-write-PM897a series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255YADJSSD module-Servers-SSD-480GB-SATA 6Gb/s-read-intensive-PM893a series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255YADKSSD module-Servers-SSD-480GB-SATA 6Gb/s-read-intensive-PM893a series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255YADLSSD module-Servers-SSD-960GB-SATA 6Gb/s-read-intensive-PM893a series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255YADMSSD module-Servers-SSD-960GB-SATA 6Gb/s-read-intensive-PM893a series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255YADNSSD module-Servers-SSD-1920GB-SATA 6Gb/s-read-intensive-PM893a series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255YADPSSD module-Servers-SSD-1920GB-SATA 6Gb/s-read-intensive-PM893a series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255YADQSSD module-Servers-SSD-3840GB-SATA 6Gb/s-read-intensive-PM893a series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255YADRSSD module-Servers-SSD-3840GB-SATA 6Gb/s-read-intensive-PM893a series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255YBMXSSD module-Servers-SSD-480GB-SATA 6Gb/s-read-intensive-2.5 inch(2.5 inch bracket)-V7 dedicated-spec code Current
0255YBMX-002SSD module-Servers-SSD-480GB-SATA 6Gb/s-read-intensive-S4520 series-2.5 inch(2.5 inch bracket)-V7 dedicated-Solidigm Current
0255YBMYSSD module-Servers-SSD-480GB-SATA 6Gb/s-read-intensive-2.5 inch(3.5 inch bracket)-V7 dedicated-spec code Current
0255YBMY-004SSD module-Servers-SSD-480GB-SATA 6Gb/s-read-intensive-S4520 series-2.5 inch(3.5 inch bracket)-V7 dedicated-Solidigm Current
0255YBNASSD module-Servers-SSD-960GB-SATA 6Gb/s-read-intensive-2.5 inch(2.5 inch bracket)-V7 dedicated-spec code Current
0255YBNA-001SSD module-Servers-SSD-960GB-SATA 6Gb/s-read-intensive-S4520 series-2.5 inch(2.5 inch bracket)-V7 dedicated-Solidigm Current
0255YBNBSSD module-Servers-SSD-960GB-SATA 6Gb/s-read-intensive-2.5 inch(3.5 inch bracket)-V7 dedicated-spec code Current
0255YBNB-004SSD module-Servers-SSD-960GB-SATA 6Gb/s-read-intensive-S4520 series-2.5 inch(3.5 inch bracket)-V7 dedicated-Solidigm Current
0255YBNQSSD module-Servers-SSD-3840GB-SATA 6Gb/s-read-intensive-2.5 inch(2.5 inch bracket)-V7 dedicated-spec code Current
0255YBNQ-002SSD module-Servers-SSD-3840GB-SATA 6Gb/s-read-intensive-S4520 series-2.5 inch(2.5 inch bracket)-V7 dedicated-Solidigm Current
0255YBNRSSD module-Servers-SSD-3840GB-SATA 6Gb/s-read-intensive-2.5 inch(3.5 inch bracket)-V7 dedicated-spec code Current
0255YBNR-002SSD module-Servers-SSD-3840GB-SATA 6Gb/s-read-intensive-S4520 series-2.5 inch(3.5 inch bracket)-V7 dedicated-Solidigm Current
0255YBNSSSD module-Servers-SSD-1920GB-SATA 6Gb/s-read-intensive-2.5 inch(2.5 inch bracket)-V7 dedicated-spec code Current
0255YBNS-001SSD module-Servers-SSD-1920GB-SATA 6Gb/s-read-intensive-S4520 series-2.5 inch(2.5 inch bracket)-V7 dedicated-Solidigm Current
0255YBNTSSD module-Servers-SSD-1920GB-SATA 6Gb/s-read-intensive-2.5 inch(3.5 inch bracket)-V7 dedicated-spec code Current
0255YBNT-004SSD module-Servers-SSD-1920GB-SATA 6Gb/s-read-intensive-S4520 series-2.5 inch(3.5 inch bracket)-V7 dedicated-Solidigm Current
0255YCAKSSD module-Servers-SSD-480GB-SATA 6Gb/s-mixed read-write-2.5 inch(2.5 inch bracket)-V7 dedicated-spec code Current
0255YCAK-001SSD module-Servers-SSD-480GB-SATA 6Gb/s-mixed read-write-S4620 series-2.5 inch(2.5 inch bracket)-V7 dedicated-Solidigm Current
0255YCALSSD module-Servers-SSD-480GB-SATA 6Gb/s-mixed read-write-2.5 inch(3.5 inch bracket)-V7 dedicated-spec code Current
0255YCAL-001SSD module-Servers-SSD-480GB-SATA 6Gb/s-mixed read-write-S4620 series-2.5 inch(3.5 inch bracket)-V7 dedicated-Solidigm Current
0255YCAMSSD module-Servers-SSD-960GB-SATA 6Gb/s-mixed read-write-2.5 inch(2.5 inch bracket)-V7 dedicated-spec code Current
0255YCAM-001SSD module-Servers-SSD-960GB-SATA 6Gb/s-mixed read-write-S4620 series-2.5 inch(2.5 inch bracket)-V7 dedicated-Solidigm Current
0255YCANSSD module-Servers-SSD-960GB-SATA 6Gb/s-mixed read-write-2.5 inch(3.5 inch bracket)-V7 dedicated-spec code Current
0255YCAN-001SSD module-Servers-SSD-960GB-SATA 6Gb/s-mixed read-write-S4620 series-2.5 inch(3.5 inch bracket)-V7 dedicated-Solidigm Current
0255YCAPSSD module-Servers-SSD-1920GB-SATA 6Gb/s-mixed read-write-2.5 inch(2.5 inch bracket)-V7 dedicated-spec code Current
0255YCAP-001SSD module-Servers-SSD-1920GB-SATA 6Gb/s-mixed read-write-S4620 series-2.5 inch(2.5 inch bracket)-V7 dedicated-Solidigm Current
0255YCAQSSD module-Servers-SSD-1920GB-SATA 6Gb/s-mixed read-write-2.5 inch(3.5 inch bracket)-V7 dedicated-spec code Current
0255YCAQ-001SSD module-Servers-SSD-1920GB-SATA 6Gb/s-mixed read-write-S4620 series-2.5 inch(3.5 inch bracket)-V7 dedicated-Solidigm Current
0255YCARSSD module-Servers-SSD-3840GB-SATA 6Gb/s-mixed read-write-2.5 inch(2.5 inch bracket)-V7 dedicated-spec code Current
0255YCAR-001SSD module-Servers-SSD-3840GB-SATA 6Gb/s-mixed read-write-S4620 series-2.5 inch(2.5 inch bracket)-V7 dedicated-Solidigm Current
0255YCASSSD module-Servers-SSD-3840GB-SATA 6Gb/s-mixed read-write-2.5 inch(3.5 inch bracket)-V7 dedicated-spec code Current
0255YCAS-001SSD module-Servers-SSD-3840GB-SATA 6Gb/s-mixed read-write-S4620 series-2.5 inch(3.5 inch bracket)-V7 dedicated-Solidigm Current
0255YDUHSSD module-Servers-SSD-480GB-SATA 6Gb/s-read-intensive-SE006 series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255YDUJSSD module-Servers-SSD-480GB-SATA 6Gb/s-read-intensive-SE006 series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255YDUMSSD module-Servers-SSD-960GB-SATA 6Gb/s-read-intensive-SE006 series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255YDUNSSD module-Servers-SSD-960GB-SATA 6Gb/s-read-intensive-SE006 series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255YDURSSD module-Servers-SSD-1920GB-SATA 6Gb/s-read-intensive-SE006 series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255YDUSSSD module-Servers-SSD-1920GB-SATA 6Gb/s-read-intensive-SE006 series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255YDUWSSD module-Servers-SSD-7680GB-SATA 6Gb/s-read-intensive-SE006 series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255YDUXSSD module-Servers-SSD-7680GB-SATA 6Gb/s-read-intensive-SE006 series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255YDXASSD module-Servers-SSD-3840GB-SATA 6Gb/s-read-intensive-SE006 series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255YDXBSSD module-Servers-SSD-3840GB-SATA 6Gb/s-read-intensive-SE006 series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255YESESSD module-Servers-SSD-960GB-SATA 6Gb/s-mixed read-write-S4620 series-2.5 inch(2.5 inch bracket)-V7 dedicated-Solidigm Current
0255YESSSSD module-Servers-SSD-3840GB-SATA 6Gb/s-read-intensive-PM893 series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255YESTSSD module-Servers-SSD-3840GB-SATA 6Gb/s-read-intensive-PM893 series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255YETESSD module-Servers-SSD-480GB-SATA 6Gb/s-read-intensive-SE006 series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255YETJSSD module-Servers-SSD-480GB-SATA 6Gb/s-read-intensive-SE006 series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255YETMSSD module-Servers-SSD-3840GB-SATA 6Gb/s-mixed read-write-PM897 series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255YETNSSD module-Servers-SSD-3840GB-SATA 6Gb/s-mixed read-write-PM897 series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255YEUNSSD module-Servers-SSD-480GB-SATA 6Gb/s-read-intensive-PM893 series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255YEURSSD module-Servers-SSD-480GB-SATA 6Gb/s-read-intensive-PM893 series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255YEUYSSD module-Servers-SSD-960GB-SATA 6Gb/s-mixed read-write-PM897 series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255YEVCSSD module-Servers-SSD-960GB-SATA 6Gb/s-mixed read-write-PM897 series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255YEVXSSD module-Servers-SSD-3840GB-SATA 6Gb/s-mixed read-write-S4620 series-2.5 inch(2.5 inch bracket)-V7 dedicated-Solidigm Current
0255YEWESSD module-Servers-SSD-3840GB-SATA 6Gb/s-mixed read-write-S4620 series-2.5 inch(3.5 inch bracket)-V7 dedicated-Solidigm Current
0255YEWKSSD module-Servers-SSD-1920GB-SATA 6Gb/s-mixed read-write-S4620 series-2.5 inch(2.5 inch bracket)-V7 dedicated-Solidigm Current
0255YEXBSSD module-Servers-SSD-960GB-SATA 6Gb/s-mixed read-write-S4620 series-2.5 inch(3.5 inch bracket)-V7 dedicated-Solidigm Current
0255YEXFSSD module-Servers-SSD-1920GB-SATA 6Gb/s-read-intensive-SE006 series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255YEXMSSD module-Servers-SSD-1920GB-SATA 6Gb/s-read-intensive-SE006 series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255YEXQSSD module-Servers-SSD-1920GB-SATA 6Gb/s-read-intensive-PM893 series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255YEXRSSD module-Servers-SSD-3840GB-SATA 6Gb/s-read-intensive-SE006 series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255YEXTSSD module-Servers-SSD-1920GB-SATA 6Gb/s-read-intensive-PM893 series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255YEXWSSD module-Servers-SSD-3840GB-SATA 6Gb/s-read-intensive-SE006 series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255YEYMSSD module-Servers-SSD-480GB-SATA 6Gb/s-mixed read-write-S4620 series-2.5 inch(3.5 inch bracket)-V7 dedicated-Solidigm Current
0255YEYPSSD module-Servers-SSD-960GB-SATA 6Gb/s-read-intensive-SE006 series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255YEYQSSD module-Servers-SSD-480GB-SATA 6Gb/s-mixed read-write-S4620 series-2.5 inch(2.5 inch bracket)-V7 dedicated-Solidigm Current
0255YEYRSSD module-Servers-SSD-1920GB-SATA 6Gb/s-mixed read-write-S4620 series-2.5 inch(3.5 inch bracket)-V7 dedicated-Solidigm Current
0255YEYTSSD module-Servers-SSD-960GB-SATA 6Gb/s-read-intensive-SE006 series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255YFACSSD module-Servers-SSD-1920GB-SATA 6Gb/s-mixed read-write-PM897 series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255YFAFSSD module-Servers-SSD-1920GB-SATA 6Gb/s-mixed read-write-PM897 series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255YFALSSD module-Servers-SSD-1920GB-SATA 6Gb/s-read-intensive-S4520 series-2.5 inch(3.5 inch bracket)-V7 dedicated-Solidigm Current
0255YFAMSSD module-Servers-SSD-1920GB-SATA 6Gb/s-read-intensive-S4520 series-2.5 inch(2.5 inch bracket)-V7 dedicated-Solidigm Current
0255YFANSSD module-Servers-SSD-3840GB-SATA 6Gb/s-read-intensive-S4520 series-2.5 inch(3.5 inch bracket)-V7 dedicated-Solidigm Current
0255YFAPSSD module-Servers-SSD-3840GB-SATA 6Gb/s-read-intensive-S4520 series-2.5 inch(2.5 inch bracket)-V7 dedicated-Solidigm Current
0255YFBDSSD module-Servers-SSD-960GB-SATA 6Gb/s-read-intensive-PM893 series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255YFBESSD module-Servers-SSD-960GB-SATA 6Gb/s-read-intensive-PM893 series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255YFCGSSD module-Servers-SSD-480GB-SATA 6Gb/s-read-intensive-S4520 series-2.5 inch(3.5 inch bracket)-V7 dedicated-Solidigm Current
0255YFCHSSD module-Servers-SSD-480GB-SATA 6Gb/s-read-intensive-S4520 series-2.5 inch(2.5 inch bracket)-V7 dedicated-Solidigm Current
0255YFCJSSD module-Servers-SSD-960GB-SATA 6Gb/s-read-intensive-S4520 series-2.5 inch(3.5 inch bracket)-V7 dedicated-Solidigm Current
0255YFCKSSD module-Servers-SSD-960GB-SATA 6Gb/s-read-intensive-S4520 series-2.5 inch(2.5 inch bracket)-V7 dedicated-Solidigm Current
0254Y398generic drive module-Servers-generic drive-12000GB-SATA 6.0Gb/s-7200rpm-3.5inch-256MB or above-hot-swap-internal-3.5 inch bracket-WD-V7 dedicated EOM
0254Y399generic drive module-Servers-generic drive-12000GB-SATA 6.0Gb/s-7200rpm-3.5inch-256MB or above-hot-swap-internal-3.5 inch bracket-Seagate-V7 dedicated EOP
0254Y443generic drive module-Servers-generic drive-16000GB-SATA 6.0Gb/s-7.2K rpm-3.5inch-hot-swap-internal-3.5 inch bracket-Toshiba-V7 dedicated EOM
0254Y445generic drive module-Servers-generic drive-16000GB-SATA 6.0Gb/s-7.2K rpm-3.5inch-256MB-hot-swap-internal-3.5 inch bracket-SEAGATE-V7 dedicated EOM
0254Y497generic drive module-Servers-generic drive-16000GB-SATA 6.0Gb/s-7.2K rpm-3.5inch-hot-swap-internal-3.5 inch bracket-WD-V7 dedicated EOM
0254Y498generic drive module-Servers-generic drive-20000GB-SATA 6.0Gb/s-7.2K rpm-256MB-3.5 inch-hot-swap-internal-3.5 inch bracket-WD-V7 dedicated EOM
0254Y499generic drive module-Servers-generic drive-20000GB-SATA 6.0Gb/s-7.2K rpm-256MB-3.5 inch-hot-swap-internal-3.5 inch bracket-Seagate-V7 dedicated EOP
0255Y397SSD module-Servers-SSD-240GB-SATA 6Gb/s-read-intensive-S4520 series-2.5 inch(2.5 inch bracket)-V7 dedicated EOM
0255Y398SSD module-Servers-SSD-240GB-SATA 6Gb/s-read-intensive-S4520 series-2.5 inch(3.5 inch bracket)-V7 dedicated EOM
0255Y399SSD module-Servers-SSD-480GB-SATA 6Gb/s-read-intensive-S4520 series-2.5 inch(2.5 inch bracket)-V7 dedicated EOM
0255Y400SSD module-Servers-SSD-480GB-SATA 6Gb/s-read-intensive-S4520 series-2.5 inch(3.5 inch bracket)-V7 dedicated EOM
0255Y401SSD module-Servers-SSD-960GB-SATA 6Gb/s-read-intensive-S4520 series-2.5 inch(2.5 inch bracket)-V7 dedicated EOM
0255Y402SSD module-Servers-SSD-960GB-SATA 6Gb/s-read-intensive-S4520 series-2.5 inch(3.5 inch bracket)-V7 dedicated EOM
0255Y403SSD module-Servers-SSD-1920GB-SATA 6Gb/s-read-intensive-S4520 series-2.5 inch(2.5 inch bracket)-V7 dedicated EOM
0255Y404SSD module-Servers-SSD-1920GB-SATA 6Gb/s-read-intensive-S4520 series-2.5 inch(3.5 inch bracket)-V7 dedicated EOM
0255Y405SSD module-Servers-SSD-3840GB-SATA 6Gb/s-read-intensive-S4520 series-2.5 inch(2.5 inch bracket)-V7 dedicated EOM
0255Y406SSD module-Servers-SSD-3840GB-SATA 6Gb/s-read-intensive-S4520 series-2.5 inch(3.5 inch bracket)-V7 dedicated EOM
0255Y407SSD module-Servers-SSD-480GB-SATA 6Gb/s-mixed read-write-S4620 series-2.5 inch(2.5 inch bracket)-V7 dedicated EOM
0255Y408SSD module-Servers-SSD-480GB-SATA 6Gb/s-mixed read-write-S4620 series-2.5 inch(3.5 inch bracket)-V7 dedicated EOM
0255Y409SSD module-Servers-SSD-960GB-SATA 6Gb/s-mixed read-write-S4620 series-2.5 inch(2.5 inch bracket)-V7 dedicated EOM
0255Y410SSD module-Servers-SSD-960GB-SATA 6Gb/s-mixed read-write-S4620 series-2.5 inch(3.5 inch bracket)-V7 dedicated EOM
0255Y411SSD module-Servers-SSD-1920GB-SATA 6Gb/s-mixed read-write-S4620 series-2.5 inch(2.5 inch bracket)-V7 dedicated EOM
0255Y412SSD module-Servers-SSD-1920GB-SATA 6Gb/s-mixed read-write-S4620 series-2.5 inch(3.5 inch bracket)-V7 dedicated EOM
0255Y413SSD module-Servers-SSD-3840GB-SATA 6Gb/s-mixed read-write-S4620 series-2.5 inch(2.5 inch bracket)-V7 dedicated EOM
0255Y414SSD module-Servers-SSD-3840GB-SATA 6Gb/s-mixed read-write-S4620 series-2.5 inch(3.5 inch bracket)-V7 dedicated EOM
0255Y415SSD module-Servers-SSD-240GB-SATA 6Gb/s-read-intensive-PM893 series-2.5 inch(2.5 inch bracket)-V7 dedicated EOP
0255Y416SSD module-Servers-SSD-240GB-SATA 6Gb/s-read-intensive-PM893 series-2.5 inch(3.5 inch bracket)-V7 dedicated EOP
0255Y442SSD module-Servers-SSD-240GB-SATA 6Gb/s-read-intensive-SE005 series-2.5 inch(2.5 inch bracket)-V7 dedicated EOP
0255Y443SSD module-Servers-SSD-240GB-SATA 6Gb/s-read-intensive-SE005 series-2.5 inch(3.5 inch bracket)-V7 dedicated EOP
0255Y444SSD module-Servers-SSD-480GB-SATA 6Gb/s-read-intensive-SE005 series-2.5 inch(2.5 inch bracket)-V7 dedicated EOM
0255Y445SSD module-Servers-SSD-480GB-SATA 6Gb/s-read-intensive-SE005 series-2.5 inch(3.5 inch bracket)-V7 dedicated EOM
0255Y446SSD module-Servers-SSD-960GB-SATA 6Gb/s-read-intensive-SE005 series-2.5 inch(2.5 inch bracket)-V7 dedicated EOM
0255Y447SSD module-Servers-SSD-960GB-SATA 6Gb/s-read-intensive-SE005 series-2.5 inch(3.5 inch bracket)-V7 dedicated EOM
0255Y448SSD module-Servers-SSD-1920GB-SATA 6Gb/s-read-intensive-SE005 series-2.5 inch(2.5 inch bracket)-V7 dedicated EOM
0255Y449SSD module-Servers-SSD-1920GB-SATA 6Gb/s-read-intensive-SE005 series-2.5 inch(3.5 inch bracket)-V7 dedicated EOM
0255Y305SSD Module,Servers,SSD,7680GB,NVMe PCIe,Read Intensive,PM9A3 Series,2.5inch(2.5inch Drive Bay),V7 dedicated Current Field replaceable
0255Y301SSD Module,Servers,SSD,1920GB,NVMe PCIe,Read Intensive,PM9A3 Series,2.5inch(2.5inch Drive Bay),V7 dedicated Current Field replaceable
0255Y303SSD Module,Servers,SSD,3840GB,NVMe PCIe,Read Intensive,PM9A3 Series,2.5inch(2.5inch Drive Bay),V7 dedicated Current Field replaceable
0254Y067Hard Disk Module,Servers,HDD,8000GB,SATA 6.0Gb/s,7.2K rpm,3.5inch,128MB cache or above,Hot_plug,Built-in,3.5 inch Drive Bay,V7 server dedicated Current Field replaceable
0254Y708Hard Disk Module,Servers,Hard Disk,1200GB,SAS 12Gb/s,10000rpm,2.5inch,128MB or above,Hot_plug,Built-in,3.5 inch Front Panel,V7 server dedicated,Seagate dedicated Current Field replaceable
0255Y946SSD Module,Servers,SSD,15360GB,NVMe PCIe,Read Intensive,-P5520 Series,2.5inch(3.5inch Drive Bay),V7 dedicated Current Field replaceable
0255Y902SSD Module,Servers,SSD,1600GB,NVMe PCIe,Mixed Use,EP600 Series,2.5inch(3.5inch Drive Bay),V7 dedicated,Global Current Field replaceable
0255Y904SSD Module,Servers,SSD,3200GB,NVMe PCIe,Mixed Use,EP600 Series,2.5inch(3.5inch Drive Bay),V7 dedicated,Global Current Field replaceable
0255Y469SSD Module,Servers,SSD,7680GB,NVMe PCIe,Read Intensive,P5520 Series,2.5inch(3.5inch Drive Bay),V7 dedicated Current Field replaceable
0255Y304SSD Module,Servers,SSD,3840GB,NVMe PCIe,Read Intensive,PM9A3 Series,2.5inch(3.5inch Drive Bay),V7 dedicated Current Field replaceable
0255Y306SSD Module,Servers,SSD,7680GB,NVMe PCIe,Read Intensive,PM9A3 Series,2.5inch(3.5inch Drive Bay),V7 dedicated Current Field replaceable
0255Y900SSD Module,Servers,SSD,7680GB,NVMe PCIe,Read Intensive,EP500 Series,2.5inch(3.5inch Drive Bay),V7 dedicated,Global Current Field replaceable
0255Y906SSD Module,Servers,SSD,6400GB,NVMe PCIe,Mixed Use,EP600 Series,2.5inch(3.5inch Drive Bay),V7 dedicated,Global Current Field replaceable
0255Y465SSD Module,Servers,SSD,1920GB,NVMe PCIe,Read Intensive,P5520 Series,2.5inch(3.5inch Drive Bay),V7 dedicated Current Field replaceable
0255Y300SSD Module,Servers,SSD,960GB,NVMe PCIe,Read Intensive,PM9A3 Series,2.5inch(3.5inch Drive Bay),V7 dedicated Current Field replaceable
0255Y467SSD Module,Servers,SSD,3840GB,NVMe PCIe,Read Intensive,P5520 Series,2.5inch(3.5inch Drive Bay),V7 dedicated Current Field replaceable
0255Y302SSD Module,Servers,SSD,1920GB,NVMe PCIe,Read Intensive,PM9A3 Series,2.5inch(3.5inch Drive Bay),V7 dedicated Current Field replaceable
0255Y898SSD Module,Servers,SSD,3840GB,NVMe PCIe,Read Intensive,EP500 Series,2.5inch(3.5inch Drive Bay),V7 dedicated,Global Current Field replaceable
0254Y700Hard Disk Module,Servers,Hard Disk,600GB,SAS 12Gb/s,10000rpm,2.5inch,128MB or above,Hot_plug,Built-in,3.5 inch Front Panel,V7 server dedicated,SEGATE dedicated Current Field replaceable
0255YBAASSD Module,Servers,SSD,6400GB,NVMe PCIe,Mixed Use,PE321 Series,2.5inch(3.5inch Drive Bay),V7 dedicated Current Field replaceable
0255Y896SSD Module,Servers,SSD,1920GB,NVMe PCIe,Read Intensive,EP500 Series,2.5inch(3.5inch Drive Bay),V7 dedicated,Global Current Field replaceable
0255YAYXSSD Module,Servers,SSD,3200GB,NVMe PCIe,Mixed Use,PE321 Series,2.5inch(3.5inch Drive Bay),V7 dedicated Current Field replaceable
0255YBVHSSD Module,Servers,SSD,7680GB,NVMe PCIe,Read Intensive,SP520 Series,2.5inch(2.5inch Drive Bay),V7 dedicated Current Field replaceable
0255YBVGSSD Module,Servers,SSD,3840GB,NVMe PCIe,Read Intensive,SP520 Series,2.5inch(3.5inch Drive Bay),V7 dedicated Current Field replaceable
0255YBVJSSD Module,Servers,SSD,7680GB,NVMe PCIe,Read Intensive,SP520 Series,2.5inch(3.5inch Drive Bay),V7 dedicated Current Field replaceable
0255YBVDSSD Module,Servers,SSD,1920GB,NVMe PCIe,Read Intensive,SP520 Series,2.5inch(2.5inch Drive Bay),V7 dedicated Current Field replaceable
0255YBVFSSD Module,Servers,SSD,3840GB,NVMe PCIe,Read Intensive,SP520 Series,2.5inch(2.5inch Drive Bay),V7 dedicated Current Field replaceable
0255YBVESSD Module,Servers,SSD,1920GB,NVMe PCIe,Read Intensive,SP520 Series,2.5inch(3.5inch Drive Bay),V7 dedicated Current Field replaceable
0255YBUNSSD Module,Servers,SSD,6400GB,NVMe PCIe,Mixed Use,SP620 Series,2.5inch(2.5inch Drive Bay),V7 dedicated Current Field replaceable
0255YBUQSSD Module,Servers,SSD,3200GB,NVMe PCIe,Mixed Use,SP620 Series,2.5inch(2.5inch Drive Bay),V7 dedicated Current Field replaceable
0255YBUPSSD Module,Servers,SSD,6400GB,NVMe PCIe,Mixed Use,SP620 Series,2.5inch(3.5inch Drive Bay),V7 dedicated Current Field replaceable
0255Y899SSD Module,Servers,SSD,7680GB,NVMe PCIe,Read Intensive,EP500 Series,2.5inch(2.5inch Drive Bay),V7 dedicated,Global Current Field replaceable
0255YBUSSSD Module,Servers,SSD,1600GB,NVMe PCIe,Mixed Use,SP620 Series,2.5inch(2.5inch Drive Bay),V7 dedicated Current Field replaceable
0255YBURSSD Module,Servers,SSD,3200GB,NVMe PCIe,Mixed Use,SP620 Series,2.5inch(3.5inch Drive Bay),V7 dedicated Current Field replaceable
0255YBUTSSD Module,Servers,SSD,1600GB,NVMe PCIe,Mixed Use,SP620 Series,2.5inch(3.5inch Drive Bay),V7 dedicated Current Field replaceable
0255Y299SSD Module,Servers,SSD,960GB,NVMe PCIe,Read Intensive,PM9A3 Series,2.5inch(2.5inch Drive Bay),V7 dedicated Current Field replaceable
0255Y476SSD Module,Servers,SSD,1600GB,NVMe PCIe,Mixed Use,P5620 Series,2.5inch(2.5inch Drive Bay),V7 dedicated Current Field replaceable
0255Y477SSD Module,Servers,SSD,1600GB,NVMe PCIe,Mixed Use,P5620 Series,2.5inch(3.5inch Drive Bay),V7 dedicated Current Field replaceable
0255Y478SSD Module,Servers,SSD,3200GB,NVMe PCIe,Mixed Use,P5620 Series,2.5inch(2.5inch Drive Bay),V7 dedicated Current Field replaceable
0255Y479SSD Module,Servers,SSD,3200GB,NVMe PCIe,Mixed Use,P5620 Series,2.5inch(3.5inch Drive Bay),V7 dedicated Current Field replaceable
0255Y903SSD Module,Servers,SSD,3200GB,NVMe PCIe,Mixed Use,EP600 Series,2.5inch(2.5inch Drive Bay),V7 dedicated,Global Current Field replaceable
0255Y905SSD Module,Servers,SSD,6400GB,NVMe PCIe,Mixed Use,EP600 Series,2.5inch(2.5inch Drive Bay),V7 dedicated,Global Current Field replaceable
0255Y901SSD Module,Servers,SSD,1600GB,NVMe PCIe,Mixed Use,EP600 Series,2.5inch(2.5inch Drive Bay),V7 dedicated,Global Current Field replaceable
0255YBARSSD Module,Servers,SSD,3840GB,NVMe PCIe,Read Intensive,PE321 Series,2.5inch(3.5inch Drive Bay),V7 dedicated Current Field replaceable
0255Y466SSD Module,Servers,SSD,3840GB,NVMe PCIe,Read Intensive,P5520 Series,2.5inch(2.5inch Drive Bay),V7 dedicated Current Field replaceable
0255Y468SSD Module,Servers,SSD,7680GB,NVMe PCIe,Read Intensive,P5520 Series,2.5inch(2.5inch Drive Bay),V7 dedicated Current Field replaceable
0255YBAQSSD Module,Servers,SSD,3840GB,NVMe PCIe,Read Intensive,PE321 Series,2.5inch(2.5inch Drive Bay),V7 dedicated Current Field replaceable
0255Y464SSD Module,Servers,SSD,1920GB,NVMe PCIe,Read Intensive,P5520 Series,2.5inch(2.5inch Drive Bay),V7 dedicated Current Field replaceable
0255Y895SSD Module,Servers,SSD,1920GB,NVMe PCIe,Read Intensive,EP500 Series,2.5inch(2.5inch Drive Bay),V7 dedicated,Global Current Field replaceable
0255Y897SSD Module,Servers,SSD,3840GB,NVMe PCIe,Read Intensive,EP500 Series,2.5inch(2.5inch Drive Bay),V7 dedicated,Global Current Field replaceable
0255Y480SSD Module,Servers,SSD,6400GB,NVMe PCIe,Mixed Use,P5620 Series,2.5inch(2.5inch Drive Bay),V7 dedicated Current Field replaceable
0255Y481SSD Module,Servers,SSD,6400GB,NVMe PCIe,Mixed Use,P5620 Series,2.5inch(3.5inch Drive Bay),V7 dedicated Current Field replaceable
0255YAYWSSD Module,Servers,SSD,3200GB,NVMe PCIe,Mixed Use,PE321 Series,2.5inch(2.5inch Drive Bay),V7 dedicated Current Field replaceable
0255YAYYSSD Module,Servers,SSD,6400GB,NVMe PCIe,Mixed Use,PE321 Series,2.5inch(2.5inch Drive Bay),V7 dedicated Current Field replaceable
0255YBFCSSD Module,Servers,SSD,3200GB,NVMe PCIe,Mixed Use,UH831a,K Series,2.5inch(2.5inch Drive Bay),V7 dedicated Current Field replaceable
0255YBERSSD Module,Servers,SSD,1600GB,NVMe PCIe,Mixed Use,UH831a,K Series,2.5inch(2.5inch Drive Bay),V7 dedicated Current Field replaceable
0255YAVHSSD Module,Servers,SSD,1600GB,NVMe PCIe,Mixed Use,UH831a-Y Series,2.5inch(2.5inch Drive Bay),V7 dedicated,New Platform Current Field replaceable
0255YAVDSSD Module,Servers,SSD,3200GB,NVMe PCIe,Mixed Use,UH831a-Y Series,2.5inch(2.5inch Drive Bay),V7 dedicated,New Platform Current Field replaceable
0255YAVFSSD Module,Servers,SSD,6400GB,NVMe PCIe,Mixed Use,UH831a-Y Series,2.5inch(2.5inch Drive Bay),V7 dedicated,New Platform Current Field replaceable
0255YBASSSD Module,Servers,SSD,7680GB,NVMe PCIe,Read Intensive,PE321 Series,2.5inch(2.5inch Drive Bay),V7 dedicated Current Field replaceable
0255YBANSSD Module,Servers,SSD,1920GB,NVMe PCIe,Read Intensive,PE321 Series,2.5inch(2.5inch Drive Bay),V7 dedicated Current Field replaceable
0255Y920SSD Module,Servers,SSD,15360GB,NVMe PCIe,Read Intensive,P5520 Series,2.5inch(2.5inch Drive Bay),V7 dedicated Current Field replaceable
0255YBNWSSD Module,Servers,SSD,6400GB,NVMe PCIe,Mixed Use,UH831a,K Series,2.5inch(2.5inch Drive Bay),V7 dedicated Current Field replaceable
0255YCRXSSD Module,Servers,SSD,15360GB,NVMe PCIe,Read Intensive,P5520 Series,2.5inch(2.5inch Drive Bay),V7 dedicated,Solidigm Current Field replaceable
0255Y620SSD Module,Servers,SSD,7680GB,NVMe PCIe,Read Intensive,UH711a-Y Series,2.5inch(2.5inch Drive Bay),V7 dedicated Current Field replaceable
0255Y621SSD Module,Servers,SSD,7680GB,NVMe PCIe,Read Intensive,UH711a-Y Series,2.5inch(3.5inch Drive Bay),V7 dedicated Current Field replaceable
0255Y616SSD Module,Servers,SSD,1920GB,NVMe PCIe,Read Intensive,UH711a-Y Series,2.5inch(2.5inch Drive Bay),V7 dedicated Current Field replaceable
0255Y617SSD Module,Servers,SSD,1920GB,NVMe PCIe,Read Intensive,UH711a-Y Series,2.5inch(3.5inch Drive Bay),V7 dedicated Current Field replaceable
0255Y618SSD Module,Servers,SSD,3840GB,NVMe PCIe,Read Intensive,UH711a-Y Series,2.5inch(2.5inch Drive Bay),V7 dedicated Current Field replaceable
0255Y619SSD Module,Servers,SSD,3840GB,NVMe PCIe,Read Intensive,UH711a-Y Series,2.5inch(3.5inch Drive Bay),V7 dedicated Current Field replaceable
0255YAYUSSD Module,Servers,SSD,1600GB,NVMe PCIe,Mixed Use,PE321 Series,2.5inch(2.5inch Drive Bay),V7 dedicated Current Field replaceable
0255YAVJSSD Module,Servers,SSD,1600GB,NVMe PCIe,Mixed Use,UH831a-Y Series,2.5inch(3.5inch Drive Bay),V7 dedicated,New Platform Current Field replaceable
0255YAVESSD Module,Servers,SSD,3200GB,NVMe PCIe,Mixed Use,UH831a-Y Series,2.5inch(3.5inch Drive Bay),V7 dedicated,New Platform Current Field replaceable
0255YAVGSSD Module,Servers,SSD,6400GB,NVMe PCIe,Mixed Use,UH831a-Y Series,2.5inch(3.5inch Drive Bay),V7 dedicated,New Platform Current Field replaceable
0255Y951SSD Module,Servers,SSD,3840GB,NVMe PCIe,Read Intensive,P5520 Series,2.5inch(3.5inch Drive Bay),V7 dedicated Current Field replaceable
0255YBFDSSD Module,Servers,SSD,3200GB,NVMe PCIe,Mixed Use,UH831a,K Series,2.5inch(3.5inch Drive Bay),V7 dedicated Current Field replaceable
0255YBESSSD Module,Servers,SSD,1600GB,NVMe PCIe,Mixed Use,UH831a,K Series,2.5inch(3.5inch Drive Bay),V7 dedicated Current Field replaceable
0254Y239Hard Disk Module,Servers,HDD,4000GB,SATA 6.0Gb/s,7200 rpm,3.5inch,128MB,Hot_plug,Built-in,3.5 inch Drive Bay,Toshiba,V7 server dedicated Current Field replaceable
0255YAETSSD Module,Servers,SSD,480GB,SATA 6Gb/s,Read Intensive,PM893 Series,2.5inch(2.5inch Drive Bay),V7 dedicated Current Field replaceable
0255YAEVSSD Module,Servers,SSD,7680GB,NVMe PCIe,Read intensive,R5100 Series,2.5inch(2.5inch Drive Bay),V7 Appoint Current Field replaceable
0255YAEFSSD Module,Servers,SSD,3840GB,NVMe PCIe,Read Intensive,P5520 Series,2.5inch(2.5inch Drive Bay),V7 dedicated Current Field replaceable
0255YBBLSSD Module,Servers,SSD,3200GB,NVMe PCIe,Mixed Use,UH831a-YSeries,2.5inch(3.5inch Drive Bay),V7 dedicated Current Field replaceable
0255YBBNSSD Module,Servers,SSD,480GB,SATA 6Gb/s,Read Intensive,ER3 Series,2.5inch(3.5inch Drive Bay),V7 dedicated Current Field replaceable
0255YDFVSSD Module,Servers,SSD,480GB,SATA 6Gb/s,Intensive,SSSTC ER3 CD Series,2.5inch(3.5inch Drive Bay),V7 dedicated Current Field replaceable
0255YDFRSSD Module,Servers,SSD,3840GB,PCIE 4.0 X4,Read Intensive,PM9A3 Series,2.5inch(3.5inch Drive Bay),NVMe SSD,V7 dedicated Current Field replaceable
0255YDFQSSD Module,Servers,SSD,3840GB,NVMe PCIe,Read Intensive,PM9A3 Series,2.5inch(2.5inch Drive Bay),V7 dedicated Current Field replaceable
0255YBBESSD Module,Servers,SSD,6400GB,NVMe PCIe,Mixed Use,UH831a,K Series,2.5inch(3.5inch Drive Bay),V7 dedicated Current Field replaceable
0255YBATSSD Module,Servers,SSD,7680GB,NVMe PCIe,Read Intensive,PE321 Series,2.5inch(3.5inch Drive Bay),V7 dedicated Current Field replaceable
0255YBAPSSD Module,Servers,SSD,1920GB,NVMe PCIe,Read Intensive,PE321 Series,2.5inch(3.5inch Drive Bay),V7 dedicated Current Field replaceable
0255YDEDSSD Module,Servers,SSD,3840GB,PCIE 5.0 X4,NVMe PCIe,Read Intensive,PS1010 Series,2.5inch(2.5inch Drive Bay),V7 dedicated Solidigm Current Field replaceable
0255YDECSSD Module,Servers,SSD,3840GB,PCIE 5.0 X4,NVMe PCIe,Read Intensive,PS1010 Series,2.5inch(3.5inch Drive Bay),V7 dedicated Solidigm Current Field replaceable
0255YBNXSSD Module,Servers,SSD,6400GB,NVMe PCIe,Mixed Use,UH831a,K Series,2.5inch(3.5inch Drive Bay),V7 dedicated Current Field replaceable
0255YEDJSSD Module,Servers,SSD,3200GB,SAS 24Gb/s,Mixed use,PM7 Series,2.5inch(2.5inch Drive Bay),18W V7 dedicated Current Field replaceable
0255YEDHSSD Module,Servers,SSD,1600GB,SAS 24Gb/s,Mixed use,PM7 Series,2.5inch(2.5inch Drive Bay),18W V7 dedicated Current Field replaceable
0255YCRYSSD Module,Servers,SSD,15360GB,NVMe PCIe,Read Intensive,P5520 Series,2.5inch(3.5inch Drive Bay),V7 dedicated,Solidigm Current Field replaceable
0255YDCXSSD Module,Servers,SSD,6400GB,NVMe PCIe 5.0 X4,Mixed Use,H5300 Series,2.5inch(3.5inch Drive Bay),V7 Dedicated Current Field replaceable
0255YDDDSSD Module,Servers,SSD,6400GB,NVMe PCIe,Mixed Use,UH831a,Y Series,2.5inch(3.5inch Drive Bay),V7 dedicated Current Field replaceable
0255YDDCSSD Module,Servers,SSD,3200GB,NVMe PCIe,Mixed Use,R5301 Series,2.5inch(3.5inch Drive Bay),V7 Dedicated Current Field replaceable
0255YDDBSSD Module,Servers,SSD,3200GB,NVMe PCIe,Mixed Use,4836 Series,2.5inch(3.5inch Drive Bay),V7 Dedicated Current Field replaceable
0255YCQPSSD Module,Servers,SSD,7680GB,PCIE 5.0 X4,NVMe PCIe,Read Intensive,H5100 Series,2.5inch(2.5inch Drive Bay),V7 dedicated Current Field replaceable
0255Y857SSD Module,Servers,SSD,3200GB,NVMe PCIe,Mixed Use,UH831a,K Series,2.5inch(3.5inch Drive Bay),V7 dedicated Current Field replaceable
0255YCKLSSD Module,Servers,SSD,3840GB,NVMe PCIe,Read Intensive,J5100 Series,2.5inch(2.5inch Drive Bay),V7 dedicated Current Field replaceable
0255YCKNSSD Module,Servers,SSD,7680GB,NVMe PCIe,Read Intensive,J5100 Series,2.5inch(2.5inch Drive Bay),V7 dedicated Current Field replaceable
0255YAYVSSD Module,Servers,SSD,1600GB,NVMe PCIe,Mixed Use,PE321 Series,2.5inch(3.5inch Drive Bay),V7 dedicated Current Field replaceable
P/NDescription / SpecificationStatus
0255Y299SSD module-Servers-SSD-960GB-NVMe PCIe-read-intensive-PM9A3 series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255Y300SSD module-Servers-SSD-960GB-NVMe PCIe-read-intensive-PM9A3 series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255Y301SSD module-Servers-SSD-1920GB-NVMe PCIe-read-intensive-PM9A3 series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255Y302SSD module-Servers-SSD-1920GB-NVMe PCIe-read-intensive-PM9A3 series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255Y303SSD module-Servers-SSD-3840GB-NVMe PCIe-read-intensive-PM9A3 series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255Y304SSD module-Servers-SSD-3840GB-NVMe PCIe-read-intensive-PM9A3 series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255Y305SSD module-Servers-SSD-7680GB-NVMe PCIe-read-intensive-PM9A3 series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255Y306SSD module-Servers-SSD-7680GB-NVMe PCIe-read-intensive-PM9A3 series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255Y616SSD module-Servers-SSD-1920GB-NVMe PCIe-read-intensive-UH711a-Y series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255Y617SSD module-Servers-SSD-1920GB-NVMe PCIe-read-intensive-UH711a-Y series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255Y618SSD module-Servers-SSD-3840GB-NVMe PCIe-read-intensive-UH711a-Y series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255Y619SSD module-Servers-SSD-3840GB-NVMe PCIe-read-intensive-UH711a-Y series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255Y620SSD module-Servers-SSD-7680GB-NVMe PCIe-read-intensive-UH711a-Y series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255Y621SSD module-Servers-SSD-7680GB-NVMe PCIe-read-intensive-UH711a-Y series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255Y896SSD module-Servers-SSD-1920GB-NVMe PCIe-read-intensive-EP500 series-2.5 inch(3.5 inch bracket)-V7 dedicated-global Current
0255Y897SSD module-Servers-SSD-3840GB-NVMe PCIe-read-intensive-EP500 series-2.5 inch(2.5 inch bracket)-V7 dedicated-global Current
0255Y898SSD module-Servers-SSD-3840GB-NVMe PCIe-read-intensive-EP500 series-2.5 inch(3.5 inch bracket)-V7 dedicated-global Current
0255Y902SSD module-Servers-SSD-1600GB-NVMe PCIe-mixed read-write-EP600 series-2.5 inch(3.5 inch bracket)-V7 dedicated-global Current
0255YAVDSSD module-Servers-SSD-3200GB-NVMe PCIe-mixed read-write-UH831a-Y series-2.5 inch(2.5 inch bracket)-V7 dedicated-new platform Current
0255YAVESSD module-Servers-SSD-3200GB-NVMe PCIe-mixed read-write-UH831a-Y series-2.5 inch(3.5 inch bracket)-V7 dedicated-new platform Current
0255YAVFSSD module-Servers-SSD-6400GB-NVMe PCIe-mixed read-write-UH831a-Y series-2.5 inch(2.5 inch bracket)-V7 dedicated-new platform Current
0255YAVGSSD module-Servers-SSD-6400GB-NVMe PCIe-mixed read-write-UH831a-Y series-2.5 inch(3.5 inch bracket)-V7 dedicated-new platform Current
0255YAVHSSD module-Servers-SSD-1600GB-NVMe PCIe-mixed read-write-UH831a-Y series-2.5 inch(2.5 inch bracket)-V7 dedicated-new platform Current
0255YAYUSSD module-Servers-SSD-1600GB-NVMe PCIe-mixed read-write-PE321 series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255YAYVSSD module-Servers-SSD-1600GB-NVMe PCIe-mixed read-write-PE321 series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255YAYWSSD module-Servers-SSD-3200GB-NVMe PCIe-mixed read-write-PE321 series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255YAYXSSD module-Servers-SSD-3200GB-NVMe PCIe-mixed read-write-PE321 series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255YAYYSSD module-Servers-SSD-6400GB-NVMe PCIe-mixed read-write-PE321 series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255YBAASSD module-Servers-SSD-6400GB-NVMe PCIe-mixed read-write-PE321 series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255YBANSSD module-Servers-SSD-1920GB-NVMe PCIe-read-intensive-PE321 series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255YBAPSSD module-Servers-SSD-1920GB-NVMe PCIe-read-intensive-PE321 series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255YBAQSSD module-Servers-SSD-3840GB-NVMe PCIe-read-intensive-PE321 series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255YBARSSD module-Servers-SSD-3840GB-NVMe PCIe-read-intensive-PE321 series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255YBASSSD module-Servers-SSD-7680GB-NVMe PCIe-read-intensive-PE321 series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255YBATSSD module-Servers-SSD-7680GB-NVMe PCIe-read-intensive-PE321 series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255YBERSSD module-Servers-SSD-1600GB-NVMe PCIe-mixed read-write-UH831a series-K-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255YBESSSD module-Servers-SSD-1600GB-NVMe PCIe-mixed read-write-UH831a-K series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255YBFCSSD module-Servers-SSD-3200GB-NVMe PCIe-mixed read-write-UH831a series-K-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255YBFDSSD module-Servers-SSD-3200GB-NVMe PCIe-mixed read-write-UH831a-K series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255YBNWSSD module-Servers-SSD-6400GB-NVMe PCIe-mixed read-write-UH831a series-K-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255YBNXSSD module-Servers-SSD-6400GB-NVMe PCIe-mixed read-write-UH831a-K series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255YBUNSSD module-Servers-SSD-6400GB-NVMe PCIe-mixed read-write-SP620 series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255YBUPSSD module-Servers-SSD-6400GB-NVMe PCIe-mixed read-write-SP620 series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255YBUQSSD module-Servers-SSD-3200GB-NVMe PCIe-mixed read-write-SP620 series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255YBURSSD module-Servers-SSD-3200GB-NVMe PCIe-mixed read-write-SP620 series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255YBUSSSD module-Servers-SSD-1600GB-NVMe PCIe-mixed read-write-SP620 series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255YBUTSSD module-Servers-SSD-1600GB-NVMe PCIe-mixed read-write-SP620 series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255YBVDSSD module-Servers-SSD-1920GB-NVMe PCIe-read-intensive-SP520 series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255YBVESSD module-Servers-SSD-1920GB-NVMe PCIe-read-intensive-SP520 series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255YBVFSSD module-Servers-SSD-3840GB-NVMe PCIe-read-intensive-SP520 series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255YBVGSSD module-Servers-SSD-3840GB-NVMe PCIe-read-intensive-SP520 series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255YBVHSSD module-Servers-SSD-7680GB-NVMe PCIe-read-intensive-SP520 series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255YBVJSSD module-Servers-SSD-7680GB-NVMe PCIe-read-intensive-SP520 series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255YCEVSSD module-Servers-SSD-3840GB-NVMe PCIe-read-intensive-2.5 inch(2.5 inch bracket)-V7 dedicated-spec code Current
0255YCEV-001SSD module-Servers-SSD-3840GB-NVMe PCIe-read-intensive-P5520 series-2.5 inch(2.5 inch bracket)-V7 dedicated-Solidigm Current
0255YCEV-006SSD module-Servers-SSD-3840GB-PCIE 5.0 X4-NVMe PCIe-read-intensive-PM9D3a series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255YCEWSSD module-Servers-SSD-3840GB-NVMe PCIe-read-intensive-2.5 inch(3.5 inch bracket)-V7 dedicated-spec code Current
0255YCEW-001SSD module-Servers-SSD-3840GB-NVMe PCIe-read-intensive-P5520 series-2.5 inch(3.5 inch bracket)-V7 dedicated-Solidigm Current
0255YCEW-006SSD module-Servers-SSD-3840GB-PCIE 5.0 X4-NVMe PCIe-read-intensive-PM9D3a series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255YCEXSSD module-Servers-SSD-7680GB-NVMe PCIe-read-intensive-2.5 inch(2.5 inch bracket)-V7 dedicated-spec code Current
0255YCEX-002SSD module-Servers-SSD-7680GB-NVMe PCIe-read-intensive-P5520 series-2.5 inch(2.5 inch bracket)-V7 dedicated-Solidigm Current
0255YCEX-007SSD module-Servers-SSD-7680GB-PCIE 5.0 X4-NVMe PCIe-read-intensive-PM9D3a series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255YCEYSSD module-Servers-SSD-7680GB-NVMe PCIe-read-intensive-2.5 inch(3.5 inch bracket)-V7 dedicated-spec code Current
0255YCEY-001SSD module-Servers-SSD-7680GB-NVMe PCIe-read-intensive-P5520 series-2.5 inch(3.5 inch bracket)-V7 dedicated-Solidigm Current
0255YCEY-005SSD module-Servers-SSD-7680GB-PCIE 5.0 X4-NVMe PCIe-read-intensive-PM9D3a series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255YCFASSD module-Servers-SSD-1600GB-NVMe PCIe-mixed read-write-2.5 inch(2.5 inch bracket)-V7 dedicated-spec code Current
0255YCFA-001SSD module-Servers-SSD-1600GB-NVMe PCIe-mixed read-write-P5620 series-2.5 inch(2.5 inch bracket)-V7 dedicated-Solidigm Current
0255YCFBSSD module-Servers-SSD-1600GB-NVMe PCIe-mixed read-write-2.5 inch(3.5 inch bracket)-V7 dedicated-spec code Current
0255YCFB-001SSD module-Servers-SSD-1600GB-NVMe PCIe-mixed read-write-P5620 series-2.5 inch(3.5 inch bracket)-V7 dedicated-Solidigm Current
0255YCFCSSD module-Servers-SSD-3200GB-NVMe PCIe-mixed read-write-2.5 inch(2.5 inch bracket)-V7 dedicated-spec code Current
0255YCFC-001SSD module-Servers-SSD-3200GB-NVMe PCIe-mixed read-write-P5620 series-2.5 inch(2.5 inch bracket)-V7 dedicated-Solidigm Current
0255YCFDSSD module-Servers-SSD-3200GB-NVMe PCIe-mixed read-write-2.5 inch(3.5 inch bracket)-V7 dedicated-spec code Current
0255YCFD-001SSD module-Servers-SSD-3200GB-NVMe PCIe-mixed read-write-P5620 series-2.5 inch(3.5 inch bracket)-V7 dedicated-Solidigm Current
0255YCFESSD module-Servers-SSD-6400GB-NVMe PCIe-mixed read-write-2.5 inch(2.5 inch bracket)-V7 dedicated-spec code Current
0255YCFE-001SSD module-Servers-SSD-6400GB-NVMe PCIe-mixed read-write-P5620 series-2.5 inch(2.5 inch bracket)-V7 dedicated-Solidigm Current
0255YCFFSSD module-Servers-SSD-6400GB-NVMe PCIe-mixed read-write-2.5 inch(3.5 inch bracket)-V7 dedicated-spec code Current
0255YCFF-001SSD module-Servers-SSD-6400GB-NVMe PCIe-mixed read-write-P5620 series-2.5 inch(3.5 inch bracket)-V7 dedicated-Solidigm Current
0255YCFQSSD module-Servers-SSD-1920GB-NVMe PCIe-read-intensive-2.5 inch(2.5 inch bracket)-V7 dedicated-spec code Current
0255YCFQ-001SSD module-Servers-SSD-1920GB-NVMe PCIe-read-intensive-P5520 series-2.5 inch(2.5 inch bracket)-V7 dedicated-Solidigm Current
0255YCFQ-003SSD module-Servers-SSD-1920GB-PCIE 5.0 X4-NVMe PCIe-read-intensive-PM9D3a series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255YCFRSSD module-Servers-SSD-1920GB-NVMe PCIe-read-intensive-2.5 inch(3.5 inch bracket)-V7 dedicated-spec code Current
0255YCFR-001SSD module-Servers-SSD-1920GB-NVMe PCIe-read-intensive-P5520 series-2.5 inch(3.5 inch bracket)-V7 dedicated-Solidigm Current
0255YCFR-004SSD module-Servers-SSD-1920GB-PCIE 5.0 X4-NVMe PCIe-read-intensive-PM9D3a series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255YCRXSSD module-Servers-SSD-15360GB-NVMe PCIe-read-intensive-P5520 series-2.5 inch(2.5 inch bracket)-V7 dedicated-Solidigm Current
0255YCRYSSD module-Servers-SSD-15360GB-NVMe PCIe-read-intensive-P5520 series-2.5 inch(3.5 inch bracket)-V7 dedicated-Solidigm Current
0255YDJCSSD module-Servers-SSD-3840GB-PCIE 5.0 X4-Vendor ID 203F-Device ID 1100-2.5inch 15mm-read-intensive-SP530 series-NVMe SSD Top-Level-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255YDJDSSD module-Servers-SSD-3840GB-PCIE 5.0 X4-Vendor ID 203F-Device ID 1100-2.5inch 15mm-read-intensive-SP530 series-NVMe SSD Top-Level-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255YDJESSD module-Servers-SSD-1920GB-PCIE 5.0 X4-Vendor ID 203F-Device ID 1100-2.5inch 15mm-read-intensive-SP530 series-NVMe SSD Top-Level-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255YDJFSSD module-Servers-SSD-1920GB-PCIE 5.0 X4-Vendor ID 203F-Device ID 1100-2.5inch 15mm-read-intensive-SP530 series-NVMe SSD Top-Level-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255YDJGSSD module-Servers-SSD-3200GB-PCIE 5.0 X4-Vendor ID 203F-Device ID 1100-2.5inch 15mm-mixed read-write-SP630 series-NVMe SSD Top-Level-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255YDJHSSD module-Servers-SSD-3200GB-PCIE 5.0 X4-Vendor ID 203F-Device ID 1100-2.5inch 15mm-mixed read-write-SP630 series-NVMe SSD Top-Level-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255YDQESSD module-Servers-SSD-1600GB-PCIE 5.0 X4-Vendor ID 203F-Device ID 1100-2.5inch 15mm-mixed read-write-SP630 series-NVMe SSD Top-Level-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255YDQFSSD module-Servers-SSD-1600GB-PCIE 5.0 X4-Vendor ID 203F-Device ID 1100-2.5inch 15mm-mixed read-write-SP630 series-NVMe SSD Top-Level-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255YDXVSSD module-Servers-SSD-7680GB-PCIE 5.0 X4-NVMe PCIe-read-intensive-R6101 series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255YDXWSSD module-Servers-SSD-7680GB-PCIE 5.0 X4-NVMe PCIe-read-intensive-R6101 series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255YEBNSSD module-Servers-SSD-6400GB-NVMe PCIe 5.0 X4-mixed read-write-R6301 series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255YEBPSSD module-Servers-SSD-6400GB-NVMe PCIe 5.0 X4-mixed read-write-R6301 series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255YEGFSSD module-Servers-SSD-3840GB-PCIE 5.0 X4-NVMe PCIe-read-intensive-R6101 series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255YEGGSSD module-Servers-SSD-3840GB-PCIE 5.0 X4-NVMe PCIe-read-intensive-R6101 series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255YEGHSSD module-Servers-SSD-3200GB-NVMe PCIe 5.0 X4-mixed read-write-R6301 series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255YEGJSSD module-Servers-SSD-3200GB-NVMe PCIe 5.0 X4-mixed read-write-R6301 series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255YESKSSD module-Servers-SSD-7680GB-PCIE 5.0 X4-NVMe PCIe-read-intensive-PM9D3a series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255YESMSSD module-Servers-SSD-7680GB-PCIE 5.0 X4-NVMe PCIe-read-intensive-PM9D3a series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255YEUASSD module-Servers-SSD-1920GB-NVMe PCIe-read-intensive-PE321 series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255YEUBSSD module-Servers-SSD-1920GB-NVMe PCIe-read-intensive-PE321 series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255YEUXSSD module-Servers-SSD-1920GB-NVMe PCIe-read-intensive-P5520 series-2.5 inch(2.5 inch bracket)-V7 dedicated-Solidigm Current
0255YEVBSSD module-Servers-SSD-1920GB-NVMe PCIe-read-intensive-P5520 series-2.5 inch(3.5 inch bracket)-V7 dedicated-Solidigm Current
0255YEVHSSD module-Servers-SSD-3200GB-NVMe PCIe-mixed read-write-PE321 series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255YEVJSSD module-Servers-SSD-3200GB-NVMe PCIe-mixed read-write-PE321 series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255YEWASSD module-Servers-SSD-3840GB-NVMe PCIe-read-intensive-PE321 series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255YEWCSSD module-Servers-SSD-3840GB-NVMe PCIe-read-intensive-PE321 series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255YEWLSSD module-Servers-SSD-1600GB-NVMe PCIe-mixed read-write-P5620 series-2.5 inch(2.5 inch bracket)-V7 dedicated-Solidigm Current
0255YEWNSSD module-Servers-SSD-1600GB-NVMe PCIe-mixed read-write-P5620 series-2.5 inch(3.5 inch bracket)-V7 dedicated-Solidigm Current
0255YEWRSSD module-Servers-SSD-7680GB-NVMe PCIe-read-intensive-PE321 series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255YEWVSSD module-Servers-SSD-1600GB-NVMe PCIe-mixed read-write-PE321 series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255YEWWSSD module-Servers-SSD-7680GB-NVMe PCIe-read-intensive-PE321 series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255YEWXSSD module-Servers-SSD-1600GB-NVMe PCIe-mixed read-write-PE321 series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255YFAQSSD module-Servers-SSD-3200GB-NVMe PCIe-mixed read-write-UH831a-K series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255YFARSSD module-Servers-SSD-3200GB-NVMe PCIe-mixed read-write-UH831a series-K-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255YFAWSSD module-Servers-SSD-6400GB-NVMe PCIe-mixed read-write-PE321 series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255YFAXSSD module-Servers-SSD-6400GB-NVMe PCIe-mixed read-write-PE321 series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255YFBVSSD module-Servers-SSD-3840GB-NVMe PCIe-read-intensive-P5520 series-2.5 inch(3.5 inch bracket)-V7 dedicated-Solidigm Current
0255YFCASSD module-Servers-SSD-3840GB-NVMe PCIe-read-intensive-P5520 series-2.5 inch(2.5 inch bracket)-V7 dedicated-Solidigm Current
0255YFCBSSD module-Servers-SSD-3200GB-NVMe PCIe-mixed read-write-P5620 series-2.5 inch(3.5 inch bracket)-V7 dedicated-Solidigm Current
0255YFCFSSD module-Servers-SSD-3200GB-NVMe PCIe-mixed read-write-P5620 series-2.5 inch(2.5 inch bracket)-V7 dedicated-Solidigm Current
0255YFCVSSD module-Servers-SSD-7680GB-NVMe PCIe-read-intensive-PM9A3 series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255YFCYSSD module-Servers-SSD-7680GB-NVMe PCIe-read-intensive-PM9A3 series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255YFDKSSD module-Servers-SSD-1920GB-NVMe PCIe-read-intensive-PM9A3 series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255YFDNSSD module-Servers-SSD-1920GB-NVMe PCIe-read-intensive-PM9A3 series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255YFDVSSD module-Servers-SSD-3840GB-NVMe PCIe-read-intensive-PM9A3 series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255YFDWSSD module-Servers-SSD-3840GB-NVMe PCIe-read-intensive-PM9A3 series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255YFEGSSD module-Servers-SSD-960GB-NVMe PCIe-read-intensive-PM9A3 series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255YFEHSSD module-Servers-SSD-960GB-NVMe PCIe-read-intensive-PM9A3 series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255Y464SSD module-Servers-SSD-1920GB-NVMe PCIe-read-intensive-P5520 series-2.5 inch(2.5 inch bracket)-V7 dedicated EOM
0255Y465SSD module-Servers-SSD-1920GB-NVMe PCIe-read-intensive-P5520 series-2.5 inch(3.5 inch bracket)-V7 dedicated EOM
0255Y466SSD module-Servers-SSD-3840GB-NVMe PCIe-read-intensive-P5520 series-2.5 inch(2.5 inch bracket)-V7 dedicated EOM
0255Y467SSD module-Servers-SSD-3840GB-NVMe PCIe-read-intensive-P5520 series-2.5 inch(3.5 inch bracket)-V7 dedicated EOM
0255Y468SSD module-Servers-SSD-7680GB-NVMe PCIe-read-intensive-P5520 series-2.5 inch(2.5 inch bracket)-V7 dedicated EOM
0255Y469SSD module-Servers-SSD-7680GB-NVMe PCIe-read-intensive-P5520 series-2.5 inch(3.5 inch bracket)-V7 dedicated EOM
0255Y476SSD module-Servers-SSD-1600GB-NVMe PCIe-mixed read-write-P5620 series-2.5 inch(2.5 inch bracket)-V7 dedicated EOM
0255Y477SSD module-Servers-SSD-1600GB-NVMe PCIe-mixed read-write-P5620 series-2.5 inch(3.5 inch bracket)-V7 dedicated EOM
0255Y478SSD module-Servers-SSD-3200GB-NVMe PCIe-mixed read-write-P5620 series-2.5 inch(2.5 inch bracket)-V7 dedicated EOM
0255Y479SSD module-Servers-SSD-3200GB-NVMe PCIe-mixed read-write-P5620 series-2.5 inch(3.5 inch bracket)-V7 dedicated EOM
0255Y480SSD module-Servers-SSD-6400GB-NVMe PCIe-mixed read-write-P5620 series-2.5 inch(2.5 inch bracket)-V7 dedicated EOM
0255Y481SSD module-Servers-SSD-6400GB-NVMe PCIe-mixed read-write-P5620 series-2.5 inch(3.5 inch bracket)-V7 dedicated EOM
0255Y895SSD module-Servers-SSD-1920GB-NVMe PCIe-read-intensive-EP500 series-2.5 inch(2.5 inch bracket)-V7 dedicated-global EOM
0255Y899SSD module-Servers-SSD-7680GB-NVMe PCIe-read-intensive-EP500 series-2.5 inch(2.5 inch bracket)-V7 dedicated-global EOM
0255Y900SSD module-Servers-SSD-7680GB-NVMe PCIe-read-intensive-EP500 series-2.5 inch(3.5 inch bracket)-V7 dedicated-global EOM
0255Y901SSD module-Servers-SSD-1600GB-NVMe PCIe-mixed read-write-EP600 series-2.5 inch(2.5 inch bracket)-V7 dedicated-global EOM
0255Y903SSD module-Servers-SSD-3200GB-NVMe PCIe-mixed read-write-EP600 series-2.5 inch(2.5 inch bracket)-V7 dedicated-global EOM
0255Y904SSD module-Servers-SSD-3200GB-NVMe PCIe-mixed read-write-EP600 series-2.5 inch(3.5 inch bracket)-V7 dedicated-global EOM
0255Y905SSD module-Servers-SSD-6400GB-NVMe PCIe-mixed read-write-EP600 series-2.5 inch(2.5 inch bracket)-V7 dedicated-global EOM
0255Y906SSD module-Servers-SSD-6400GB-NVMe PCIe-mixed read-write-EP600 series-2.5 inch(3.5 inch bracket)-V7 dedicated-global EOM
0255Y920SSD module-Servers-SSD-15360GB-NVMe PCIe-read-intensive-P5520 series-2.5 inch(2.5 inch bracket)-V7 dedicated EOM
0255Y946SSD module-Servers-SSD-15360GB-NVMe PCIe-read-intensive--P5520 series-2.5 inch(3.5 inch bracket)-V7 dedicated EOM
0255YAVJSSD module-Servers-SSD-1600GB-NVMe PCIe-mixed read-write-UH831a-Y series-2.5 inch(3.5 inch bracket)-V7 dedicated-new platform EOM
0255YBWESSD Module,Servers,M.2 SSD,NVMe PCIe,1920GB,80.0mm * 22.0mm * 3.58 mm(Non-hot-swappable),PJ1 series Current Field replaceable
0255YCUYSSD Module,Servers,M.2 SSD,NVMe PCIe,480GB,80.0mm * 22.0mm * 3.58 mm(Non-hot-swappable),PM9A3 series Current Field replaceable
0255Y696SSD Module,Servers,M.2 SSD,SATA 6Gb/s-240GB,80.0mm * 22.0mm * 3.58 mm(Non-hot-swappable),ER3 series Current Field replaceable
0255Y698SSD Module,Servers,M.2 SSD,SATA 6Gb/s-480GB,80.0mm * 22.0mm * 3.58 mm(Non-hot-swappable),ER3 series Current Field replaceable
0255YCULSSD Module,Servers,M.2 SSD,NVMe PCIe,960GB,80.0mm * 22.0mm * 3.58 mm(Non-hot-swappable),PJ1 series Current Field replaceable
0255Y697SSD Module,Servers,M.2 SSD,SATA 6Gb/s-480GB,80.0mm * 22.0mm * 3.58 mm(hot-swappable),ER3 series Current Field replaceable
0255YGFSSSD Module,Servers,M.2 SSD,NVMe PCIe,960GB,80.0mm * 22.0mm * 3.58 mm,PJ1 series Current Field replaceable
0255Y695SSD Module,Servers,M.2 SSD,SATA 6Gb/s-240GB,80.0mm * 22.0mm * 3.58 mm(hot-swappable),ER3 series Current Field replaceable
0255YCNWSSD Module,Servers,M.2 SSD,SATA 6Gb/s-960GB,80.0mm * 22.0mm * 3.58 mm(Non-hot-swappable),ER3 series Current Field replaceable
0255YCTXSSD Module,Servers,M.2 SSD,SATA 6Gb/s-480GB,80.0mm * 22.0mm * 3.58 mm(Non-hot-swappable),ER3 series,V7 dedicated Current Field replaceable
P/NDescription / SpecificationStatus
02312QWWfunction module-9460-8i 4G-CN2M94608I4G-9460-8i 4G other board card-12G SAS RAID card-4G cache-8*12Gb/s SAS PHY-2 miniSAS HD internal interface-PCIE 3.1 X8-Vendor ID 1000-Device ID 0016-1-Subvendor ID 1000-Subdevice ID 9461 Current
02312QWYfunction module-9440-8i 0G-CN2M94408I0G-9440-8i 0G other board card-12G SAS RAID card-no cache-8*12Gb/s SAS PHY-2 miniSAS HD internal interface-PCIE 3.1 X8-Vendor ID 1000-Device ID 0017-1-Subvendor ID 1000-Subdevice ID 9440 Current
02312SJGfunction module-9460-16i 4G-CN2M946016I4G-9460-16i 4G other board card-12G SAS RAID card-4G cache-16*12Gb/s SAS PHY-4 miniSAS HD internal interface-PCIE 3.1 X8-Vendor ID 1000-Device ID 0014-1-Subvendor ID 1000-Subdevice ID 9460 Current
0231Y131function module-9560-16i 8G-CN2M956016I8G-9560-16i 8G other board card-12G SAS RAID card-8G cache-16*12Gb/s SAS PHY-2 slimline internal interface-PCIE 4.0 X8-Vendor ID 1000-Device ID 10E2-Subvendor ID 1000-Subdevice ID 4000 Current
0231Y338function module-Public Module-CN2M05RLCAC-XP460C-M 4G SAS/SATA/NVMe RAID card standardcard,RAID0,1,5,6,10,50,60,4GB Cache(Avago3516),supports supercap & sideband management-full-height half-length-PCIE 3.0 X8-Vendor ID 1000-Device ID 0014 Current
0231Y651function module-9500-8i-CN2M95008I-PCIE 4.0 X8-Vendor ID 1000-Device ID 00E6-1-Subvendor ID 1000-Subdevice ID 4060-12G SAS RAID card-x8 PCIe 4.0-9500-8i SAS RAID Card,SAS3808,No CacheVault,12Gb/s SAS,6Gb/s SATA,PCIe(NVMe)-9500-8i Current
0231Y652function module-9500-16i-CN2M950016I-PCIE 4.0 X8-Vendor ID 1000-Device ID 00E6-1-Subvendor ID 1000-Subdevice ID 4050-12G SAS RAID card-x8 PCIe 4.0-9500-16i SAS RAID Card,SAS3816,No CacheVault,12Gb/s SAS,6Gb/s SATA,PCIe(NVMe)-9500-16i Current
0231Y735function module-9540-8i-CN2M95408I-PCIE 4.0 X8-Vendor ID 1000-Device ID 10E6-1-Subvendor ID 1000-Subdevice ID 40D5-12G SAS RAID-9540-8i-x8 PCIe 4.0-9540-8i SAS RAID Card,SAS3808,No CacheVault,12Gb/s SAS,6Gb/s SATA,PCIe(NVMe)-9540-8i Current
0231Y736function module-9540-16i-CN2M954016I-PCIE 4.0 X8-Vendor ID 1000-Device ID 10E6-1-Subvendor ID 1000-Subdevice ID 40D0-12G SAS RAID-x8 PCIe 4.0-9540-16i SAS RAID Card,SAS3816,No CacheVault,12Gb/s SAS,6Gb/s SATA,PCIe(NVMe)-9540-16i Current
0231YBWVfunction module-Public Module-BC5M01RLAD-XC470C-M-8i 4G-(SAS3908)-RAID cable card-RAID0,1,5,6,10,50,60-12Gb/s-4GB Cache-supports supercap & sideband management-PCIE 4.0 X8-Vendor ID 1000-Device ID 10E2-1-Subvendor ID 1F24-Subdevice ID 3000 Current
0231YBWXfunction module-Public Module-BC5M01RLADB-XC470C-M-16i 4G-(SAS3916)-RAID cable card-RAID0,1,5,6,10,50,60-12Gb/s-4GB Cache-supports supercap & sideband management-PCIE 4.0 X8-Vendor ID 1000-Device ID 10E2-1-Subvendor ID 1F24-Subdevice ID 3001 Current
0231YBWYfunction module-Public Module-BC5M01RLAE-XC170-M-8i-(SAS3808iMR)-SAS/SATA RAID cable card-RAID0,1,10-12Gb/s-no Cache-supports sideband management-PCIE 4.0 X8-Vendor ID 1000-Device ID 10E6-1-Subvendor ID 1F24-Subdevice ID 3002 Current
0231YBXAfunction module-Public Module-BC5M01RLAEA-XC170-M-16i-(SAS3816iMR)-SAS/SATA RAID cable card-RAID0,1,10-12Gb/s-no Cache-supports sideband management-PCIE 4.0 X8-Vendor ID 1000-Device ID 10E6-1-Subvendor ID 1F24-Subdevice ID 3005 Current
0231YBXCfunction module-Public Module-BC5M01RLAEC-XC370-M-16i-(SAS3816IT)-SAS/SATA RAID cable card-None RAID-12Gb/s-no Cache-supports sideband management-PCIE 4.0 X8-Vendor ID 1000-Device ID 00E6-1-Subvendor ID 1F24-Subdevice ID 3007 Current
0256Y064RAID card module-Public Module-BC5M01RLAH1-XP270-M2-(SAS3808-BootCard)-M.2 RAID standardcard-RAID0,1,JBOD-No Cache-supports sideband management-half-height half-length-full-height bracket-PCIe 4.0 x8 Current
0256Y066RAID card module-Public Module-BC5M02RLAH1-XP270-M2-(SAS3808-BootCard)-M.2 RAID standardcard-RAID0,1,JBOD-No Cache-supports sideband management-half-height half-length-half-height bracket-PCIe 4.0 x8 Current
0256Y097RAID card module-2258 V7-MegaRAID 9670W-16i-other board card-PCIE 4.0 X16-Vendor ID 1000-Device ID 00A5-1-Subvendor ID 1000-Subdevice ID 4600-22.5G SAS RAID card-SAS4116W,16 internal phy,8G CacheVault,CVPM05,RAID0/1/5/6-9670W-16i-English documentation Current
0256Y106RAID card module-2288H V7-Dapustor F6100-PCIE 4.0 X4-Vendor ID 1e3b-Device ID 50b1-1-Subvendor ID 1e3b-Subdevice ID 50b1-PCIE 4.0 X4-Dapustor F6100 RAID Card-DP808AL-6Gb/s SATA,PCIE5.0 X2 NVMe-Chinese documentation Current
0256Y146RAID card module-Public Module-CN2M95808I8E-PCIe 4.0 x8-9580-8i8e SAS RAID Card,SAS3916,8G CacheVault,CVPM05-12Gb/s SAS,6Gb/s SATA,PCIe(NVMe)-included 1pcs low-profile bracket-for use with matching drive backplane Current
0256Y174RAID card module-2288H V7-9560-8i 4G-12G SAS RAID card-9560-8i-(SAS3908)-CVPM05-12Gb/s SAS-6Gb/s SATA-PCIe(NVMe)-4G CacheVault-PCIE 4.0 X8-Vendor ID 1000-Device ID 10E2-Subvendor ID 1000-Subdevice ID 4010 Current
0256Y179RAID card module-2288H V7-9560-16i 8G-12G SAS RAID card-9560-16i-(SAS3916)-CVPM05-12Gb/s SAS,6Gb/s SATA,PCIe(NVMe)-8G CacheVault-PCIE 4.0 X8-Vendor ID 1000-Device ID 10E2-Subvendor ID 1000-Subdevice ID 4000 Current
02312QWVfunction module-9460-8i 2G-CN2M94608I2G-9460-8i 2G other board card-12G SAS RAID card-2G cache-8*12Gb/s SAS PHY-2 miniSAS HD internal interface-PCIE 3.1 X8-Vendor ID 1000-Device ID 0016-1-Subvendor ID 1000-Subdevice ID 9461 EOM
0231Y129function module-9560-8i 4G-CN2M95608I4G-9560-8i 4G other board card-12G SAS RAID card-4G cache-8*12Gb/s SAS PHY-1 slimline internal interface-PCIE 4.0 X8-Vendor ID 1000-Device ID 10E2-Subvendor ID 1000-Subdevice ID 4010 EOM
0817Y002Super capacitor module,64mm*51mm*13.1mm,Wire mounting,split from 08170002,NA,7600uF,5h Current Field replaceable
0302Y201Manufactured Board-JDM,Public Module,BC55RLAD,XC470C-M-8i 4G-(SAS3908)-RAID Cable Card-RAID0,1,5,6,10,50,60-12Gb/s-4GB Cache,Capacitor and Management,PCIE 4.0 X8-Vendor ID 1000-Device ID 10E2-1-Subvendor ID 1F24-Subdevice ID 3000,1*1 Current Field replaceable
0302Y204Manufactured Board-JDM,Public Module,BC56RLAE,XC170-M-8i-(SAS3808iMR)-SAS/SATA RAID Cable Card-RAID0,1,10-12Gb/s-no Cache,Support Sideband Management,PCIE 4.0 X8-Vendor ID 1000-Device ID 10E6-1-Subvendor ID 1F24-Subdevice ID 3002,1*1 Current Field replaceable
0302Y203Manufactured Board-JDM,Public Module,BC55RLADB,XC470C-M-16i 4G-(SAS3916)-RAID Cable Card-RAID0,1,5,6,10,50,60-12Gb/s-4GB Cache, Capacitor and Management,PCIE 4.0 X8-Vendor ID 1000-Device ID 10E2-1-Subvendor ID 1F24-Subdevice ID 3001,1*1 Current Field replaceable
0231Y752Function Module,9580-8i8e,CN2M95808I8E,PCIe 4.0 x8-9580-8i8e SAS RAID Card,SAS3916, 8G CacheVault,CVPM05-12Gb/s SAS,6Gb/s SATA,PCIe(NVMe)-9580-8i8e,Comes with 1pcs short flap Current Field replaceable
0302Y205Manufactured Board-JDM,Public Module,BC56RLAEA,XC170-M-16i-(SAS3816iMR)-SAS/SATA RAID Cable Card-RAID0,1,10-12Gb/s-no Cache,Support Sideband Management,PCIE 4.0 X8-Vendor ID 1000-Device ID 10E6-1-Subvendor ID 1F24-Subdevice ID 3005,1*1 Current Field replaceable
0302Y207Manufactured Board-JDM,Public Module,BC56RLAEC,XC370-M-16i-(SAS3816IT)-SAS/SATA RAID Cable Card-None RAID-12Gb/s-no Cache,Support Sideband Management,PCIE 4.0 X8-Vendor ID 1000-Device ID 00E6-1-Subvendor ID 1F24-Subdevice ID 3007,1*1 Current Field replaceable
P/NDescription / SpecificationStatus
0231Y752function module-9580-8i8e-CN2M95808I8E-PCIe 4.0 x8-9580-8i8e SAS RAID Card,SAS3916,8G CacheVault,CVPM05-12Gb/s SAS,6Gb/s SATA,PCIe(NVMe)-9580-8i8e-included 1pcs low-profile bracket Current
0231Y803function module-Servers-CN2M01ITGBA1-XP210 Intel I350 2*GE+half-height half-length(incl. half-height & full-height brackets)standard network adapter-PCIE 2.0 X4-Vendor ID 8086-Device ID 1521-2 Current
0231Y804function module-Servers-CN2M01ITGC1-XP212 Intel I350 4*GE+half-height half-length(incl. half-height & full-height brackets)standard network adapter-PCIE 2.0 X4-Vendor ID 8086-Device ID 1521-4 Current
0231Y809function module-Servers-CN2M04ITGG1-XP330 Ethernet adapter-10Gb optical port(Intel X710)-dual-port-SFP+(optical module not included)-half-height half-length(incl. half-height & full-height brackets)-PCIe 3.0 x8 Current
0231Y821function module-Servers-BC5M01ETHK1-XP382 Ethernet adapter-25GE optical port(Mellanox CX5)-dual-port-SFP28(optical module not included)-half-height half-length(incl. half-height & full-height brackets)-PCIe 3.0 x8 Current
0231Y830function module-Servers-CN2M05ITGH1-XP332 Ethernet adapter-10Gb optical port(Intel XL710)-quad-port-SFP(incl. 4 optical modules)-half-height half-length(incl. half-height & full-height brackets)-PCIe 3.0 x8(domestic & overseas) Current
0257Y058PCIe-GPU card-2288H V7-BC3A16GPU64-NA016 PCIe compute card-64GB-PCIe 4.0 x16 Current
0257Y099PCIe-network adapter-2288H V6-E810XXVDA2G1P5-network adapter-25G optical port(E810XXVDA2G1P5 978333)-dual-port-SFP28(optical module not included)-PCIE 4.0 X8-8086-159b|0003-2-with driver package Current
0257Y101PCIe-network adapter-2288H V6-E810CQDA2-network adapter-100G optical port(E810CQDA2G2P5 99A454)-dual-port-QSFP28(optical module not included)-PCIE 4.0 X16-8086-1592|0002-2-with driver package Current
0257Y102PCIe-network adapter-2288H V6-MCX631102AN-ADAT-network adapter-25 GE-64bit-SFP28-2-PCIE 4.0 x8-15b3-101f-2-with driver package Current
0257Y109PCIe-network adapter-2288H V6-LPE31000-AP-Emulex -FC HBA card-16Gb/s(LPe31000)-single-port-SFP+(incl. 1 multimode optical modules)-PCIE 3.0 x8-Vendor ID 10DF-Device ID E300-1-Subvendor ID 10DF-Subdevice ID E311-with driver package Current
0257Y110PCIe-network adapter-2288H V6-LPe31002-AP-Emulex -FC HBA card-16Gb/s(LPe31002)-dual-port-SFP+(incl. 2 multimode optical modules)-PCIE 3.0 x8-Vendor ID 10DF-Device ID E300-2-Subvendor ID 10DF-Subdevice ID E310-with driver package Current
0257Y112PCIe-network adapter-2288H V6-LPe32002-AP-Emulex -FC HBA card-32Gb/s(LPe320PCIE 3.0 x8-Vendor ID 10DF-Device ID E300-2-Subvendor ID 10DF-Subdevice ID E30002)-dual-port-SFP+(incl. 2 multimode optical modules)--with driver package Current
0257Y114PCIe-network adapter-2288H V6-MCX653105A-HDAT-Infiniband MCX653105A-HDAT-200Gb/s-64bit-QSFP56-1port-PCIE 4.0 x16-Vendor ID 15b3-Device ID 101b-1-Subvendor ID 15b3-Subdevice ID 0007-with driver package Current
0257Y116PCIe-network adapter-2288H V6-X710T2L-10Gb/s-64bit-10GBASE-T-2 ports-PCIE 3.0 x8-8086-15ff-2-with driver package Current
0257Y117PCIe-network adapter-2288H V6-E810XXVDA4-network adapter-25G optical port(E810XXVDA4G2P5 99A2H8)-quad-port-SFP28(optical module not included)-PCIE 4.0 X16-8086-1593|0005-4-full-height half-length-with driver package Current
0257Y120PCIe-network adapter-2288H V6-X2522-25G-Plus-network adapter-25 Gigabit-64bit-SFP28-2 ports-PCIE 3.0 x8-1924-0b03-2-with driver package Current
0257Y122PCIe-network adapter-5885H V7-LPE35000-AP-Emulex -HBA Card LPE35000-AP-FC single-port-32Gb/s-PCIE 4.0 x8-Vendor ID 10DF-Device ID F400-1-with driver package Current
0257Y123PCIe-network adapter-5885H V7-LPE35002-AP-Emulex -HBA Card LPE35002-AP-FC dual-port-32Gb/s-PCIE 4.0 x8-Vendor ID 10DF-Device ID F400-2-with driver package Current
0257Y125PCIe-network adapter-5885H V7-QLE2772-CEM-BK-Qlogic-HBA Card QLE2772-CEM-BK-FC dual-port-32Gb/s-PCIE 4.0 x8-Vendor ID 1077-Device ID 2281-2-with driver package Current
0257Y150PCIe-network adapter-2288H V6-MCX623106AN-CDAT-network adapter-100Gb optical port(MCX623106AN-CDAT)-dual-port-QSFP56(optical module not included)-half-height half-length-PCIE 4.0 x16-15b3-101d-2-with driver package Current
0257Y151PCIe-network adapter-2288H V6-BCM957412A4120AC-network adapter-10 Gigabit-64bit-SFP+-2-PCIE 3.0 x8-14e4-16d6-2-with driver package Current
0257Y152PCIe-network adapter-2288H V6-N25GPCIE03-network adapter-25Gb optical port(BCM957414A4142CC)-dual-port-SFP28(optical module not included)-PCIE 3.0 x8-14e4-16d7-2-with driver package Current
0257Y246PCIe-IB card-G8600 V7-MCX755106AS-HEAT-Infiniband MCX755106AS-HEAT-200Gb/s NDR200 IB,dual-port QSFP112-PCIE 5.0 x16-Vendor ID 15B3-Device ID 1021-2-Subvendor ID 15B3-Subdevice ID 0022(optical module not included) Current
0257Y302PCIe-network adapter-2288H V6-LPE36002-LPe36002-AP-FC HBA card-64Gb/s-dual-port-PCIE 4.0 x8-Vendor ID 10df-Device ID f400-2-Subvendor ID 10df-Subdevice ID f404-with driver package Current
0257Y390PCIe-network adapter-2288H V7-MCX75310AAS-NEAT-IB card-Infiniband MCX75310AAS-NEAT-NDR/NDR200/HDR100/EDR IB single-port OSFP-400Gb/s-PCIE 5.0 x16-Vendor ID 15B3-Device ID 1021-1-Subvendor ID 15B3-Subdevice ID 0023-with driver package Current
0257Y391PCIe-network adapter-2288H V7-MCX75310AAS-HEAT-IB card-Infiniband MCX75310AAS-HEAT-200Gb/s NDR200 IB,single-port OSFP-PCIE 5.0 x16-Vendor ID 15B3-Device ID 1021-1-Subvendor ID 15B3-Subdevice ID 0029-with driver package Current
0257Y476PCIe-network adapter-2288H V7-BCM957608-P2200GQF00-network adapter-200 Gigabit-64bit-QSFP56-2 ports-PCIE 5.0 x16-Vendor ID 14e4-Device ID 1760-2-Subvendor ID 14e4-Subdevice ID 9120-with driver package Current
0257Y506PCIe-GPU card-2258 V7-NVIDIA L2 GPU-GPU card-NVIDIA L2 GPU Accelerator-PN:900-2G193-0030-000/24GB GDDR6 Memory/300GB/s peak Memory Bandwidth/PCIE 4.0 x16-10DE-27B6-1,72W/HHHL,single-slot/Passive cooling-English documentation-No Cable Current
0257Y516PCIe-network adapter-2258 V7-BCM957504-P425G-network adapter-25G(BCM957504-P425G)-64bit-SFP28(optical module not included)-4 ports-PCIE 4.0 x16-Vendor ID 14e4-Device ID 1751-4-Subvendor ID 14e4-Subdevice ID 4250 Current
0257Y520PCIe-network adapter-2288H V7-BCM957508-P2100G-network adapter-100Gb optical port-dual-port-QSFP28-half-height half-length-PCIE 4.0 x16-Vendor ID 14e4-Device ID 1750-2-Subvendor ID 14e4-Subdevice ID 2100 Current
0257Y551PCIe-network adapter-G5500 V7-BCM957608-P1400GDF00-network adapter-400 Gigabit-64bit-QSFP-DD-1 port-PCIE 5.0 x16-Vendor ID 14e4-Device ID 1760-1-Subvendor ID 14e4-Subdevice ID 9140 Current
0257Y565PCIe-GPU card-2258 V7-BC3L20GPU48-GPU card-NL02 GPU Accelerator-PN:900-2G133-00A0-000/48GB GDDR6 Memory/864GB/s Memory Bandwidth/PCIE 4.0 x16-10DE-26BA-1/350W-No NVLink-English documentation-Dual slot-Passive-FHFL Current
0257Y577PCIe-network adapter-2288H V7-FF5025-DDATACXX-network adapter-25 GE-64bit-SFP28-2-PCIE 4.0 X8-Vendor ID 8088-Device ID 5025-2-Subvendor ID 8088-Subdevice ID 1000 Current
0257Y665PCIe-network adapter-2258 V7-E610XT2M5-PCIE 4.0 X4-Vendor ID 8086-Device ID 57b0-2-Subvendor ID 8086-Subdevice ID 0002 Current
0257Y716PCIe-GPU card-2258 V7-SL200-NP-Ramaxel StreamLake SL200-NP PCIe-full-height half-length/PCIE 3.0 x4-1024-0101-2-70W/single-slot/passive cooling/-Chinese documentation-No Cable Current
0257Y821PCIe-network adapter-2258 V7-E835XXVDA2M-network adapter-2*25GE-64bit-SFP28-2 Ports-PCIE 4.0 X8-Vendor ID 8086-Device ID 124A-2-Subvendor ID 8086-Subdevice ID 0008-half-height half-length Current
0231Y815function module-Servers-BC5M02ETHE1-XP380 Ethernet adapter-25GE optical port(Mellanox CX-4 Lx)-dual-port-SFP28(optical module not included)-half-height half-length-full-height bracket-PCIe 3.0 x8 EOM
0257Y094PCIe-network adapter-2288H V6-MCX4121A-ACAT-Ethernet adapter-25Gb optical port(Mellanox CX4-lx EN)-dual-port-SFP28(optical module not included)-PCIE 3.0 X8-15b3-1015-2-with driver package EOP
0257Y095PCIe-network adapter-2288H V6-MCX512A-ACAT-network adapter-25Gb optical port(MCX512A-ACAT)-dual-port-SFP28(optical module not included)-PCIE 3.0 x8-15b3-1017-2-Subvendor ID 15b3-Subdevice ID 0020-with driver package EOP
0257Y096PCIe-network adapter-2288H V6-MCX512A-ACUT-network adapter-25Gb optical port(MCX512A-ACUT)-dual-port-SFP28(optical module not included)-PCIE 3.0 x8-15b3-1017-2-with driver package EOP
0257Y098PCIe-network adapter-2288H V6-XXV710DA2-Ethernet adapter-25Gb optical port(Intel-XXV710)-dual-port-SFP28(optical module not included)-PCIE 3.0 X8-8086-158b-2-with driver package EOM
0257Y113PCIe-network adapter-2288H V6-MCX653105A-ECAT-Infiniband MCX653105A-ECAT-HDR100/EDR IB single-port-100Gb/s-PCIE 4.0 x16-Vendor ID 15b3-Device ID 101b-1|2-Subvendor ID 15b3-Subdevice ID 0006-with driver package EOM
0257Y178PCIe-network adapter-2288H V6-MCX516A-CCAT-network adapter-100 Gigabit-64bit-QSFP28(optical module not included)-2 Ports-PCIE 3.0 x16-Vendor ID 15b3-Device ID 1017-2-Subvendor ID 15b3-Subdevice ID 0007-with driver package EOP
0257Y209PCIe-network adapter-2288H V6-MCX75310AAS-NEAT-MELLANOX MCX75310AAS-NEAT NDR/NDR200/HDR100/EDR IB card-400Gb/s-single-port-OSFP-PCIE 5.0 x16-Vendor ID 15B3-Device ID 1021-1-Subvendor ID 15B3-Subdevice ID 0023-(only supports IB mode) EOP
0257Y211PCIe-network adapter-2288H V6-MCX75310AAS-HEAT-IB card-Infiniband MCX75310AAS-HEAT-200Gb/s NDR200 IB,single-port OSFP-PCIE 5.0 x16-Vendor ID 15B3-Device ID 1021-1-Subvendor ID 15B3-Subdevice ID 0029-with driver package-(only supports IB mode) EOP
0257Y230PCIe-network adapter-2288H V6-MCX653106A-ECAT-other board card-Infiniband MCX653106A-ECAT-HDR100/EDR 100GbE IB dual-port-100Gb/s-PCIE 4.0 x16-Vendor ID 15b3-Device ID 101b-2-Subvendor ID 15b3-Subdevice ID 0008-with driver package EOP
0257Y581PCIe-network adapter-2258 V7-BCM957416A4160C-network adapter-2*10GE-64bit-RJ45-2-PCIE 3.0 x8-Vendor ID 14e4-Device ID 16d8-2-Subvendor ID 14e4-Subdevice ID 1602 EOM
3406Y008High Speed Transceiver,SFP28,850nm,25G,-8.4dBm,2.4dBm,-10.3dBm,LC,MM,0.1km,Original 34061254 split Current Field replaceable
3406Y006XFP|SFP+ Transceiver,SFP+,850nm,10Gb/s,-7.3dBm,-1dBm,-9.9dBm,LC,0.3km Current Field replaceable
34061089High Speed Transceiver,QSFP28,850nm,100G,-8.4dBm,2.4dBm,-10.3dBm,MPO,MM,0.1km,OM4 Current Engineer replace
34061254High Speed Transceiver,SFP28,850nm,25G,-8.4dBm,2.4dBm,-10.3dBm,LC,MM,0.1km Current Field replaceable
3406Y011High Speed Transceiver,QSFP28,850nm,100G,-8.4dBm,2.4dBm,-10.3dBm,MPO,MM,0.1km,OM4 Original 34061089 split Current Field replaceable
3406Y007XFP|SFP+ Transceiver,SFP+,1310nm,10Gb/s,-8.2dBm,0.5dBm,-12.6dBm,LC,10km Current Field replaceable
0631Y005Network Card,25Gb/s,64bit,SFP28,2 ports,PCIE 4.0 x8-15b3-101f-2,No Driver CD,OCP Current Field replaceable
0631Y027Network Card,100GE,64bit,QSFP56(without Optical Transceiver),2 Ports,PCIE 4.0 x16-15b3-101d-2,No Driver CD Current Field replaceable
0302Y437Manufactured Board,XP380,BC51ETHE3,Ethernet Adapter,25GE(Mellanox CX-4 Lx),Dual-Port,SFP28(without Optical Transceiver),PCIE 3.0 x8-Vendor ID 15b3-Device ID 1015-2-Subvendor ID 1f24-Subdevice ID 2005,1*2 Current Field replaceable
0302Y043Manufactured Board,Public Module,CN21ITGBA1,XP210 I350 2*GE PCIE Card,PCIE 2.0 X4-Vendor ID 8086-Device ID 1521-2-Subvendor ID 1f24-Subdevice ID 2000,1*2 Current Field replaceable
0631Y037Network Card,10 Gigabit,64bit,SFP+,2,PCIE 3.0 x8-14e4-16d6-2,No Driver CD Current Field replaceable
0302Y044Manufactured Board,Public Module,CN21ITGC1,XP212 I350 4*GE PCIE Card,PCIE 2.0 X4-Vendor ID 8086-Device ID 1521-4-Subvendor ID 1f24-Subdevice ID 2001,1*2 Current Field replaceable
0302Y047Manufactured Board,Public Module,CN21ITGH1,XP332 Ethernet Adapter,10Gb Optical Interface(Intel XL710),4-Port,SFP+(without Optical Transceiver),PCIE 3.0 X8-Vendor ID 8086-Device ID 1572-4-Subvendor ID 1f24-Subdevice ID 2004,1*2 Current Field replaceable
06310191Network Card,25 Gigabit,64bit,SFP28,2 ports,PCIE 3.0 X8-15b3-1015-2,No Driver CD Current Field replaceable
0302Y049Manufactured Board,Public Module,BC51ETHK1,XP382 Ethernet Adapter,25GE(Mellanox CX-5 Lx),Dual-Port,SFP28(without Optical Transceiver),PCIE 3.0 x8-Vendor ID 15b3-Device ID 1017-2-Subvendor ID 1f24-Subdevice ID 2006,1*2 Current Field replaceable
06310169Network Card,25 Gigabit,64bit,SFP28(without Optical Transceiver),2 Ports,PCIE 3.0 x8-15b3-1017-2,No Driver CD-A baffle plate is delivered with the incoming material Current Field replaceable
0631Y040Network Card,25 GE,64bit,SFP28,2,PCIE 4.0 x8-15b3-101f-2,No Driver CD Current Field replaceable
06030393Other Cards,HBA Card LPe32002-AP,FC Double Ports-32Gb/s,PCIE 3.0 x8-Vendor ID 10DF-Device ID E300-2-Subvendor ID 10DF-Subdevice ID E300,English doc,1pcs short bracket,half width half length-Prohibition of separate shipment Current Field replaceable
06030516IB Card,Infiniband MCX653105A-ECAT,HDR100/EDR single-port -100Gb/s- PCIE 4.0 x16-Vendor ID 15b3-Device ID 101b-1|2-Subvendor ID 15b3-Subdevice ID 0006-tall bracket,English doc Current Field replaceable
0603Y018IB Card,Infiniband MCX653105A-HDAT,200Gb/s-64bit-QSFP56-1port,PCIE 4.0 x16-Vendor ID 15b3-Device ID 101b-1-Subvendor ID 15b3-Subdevice ID 0007,Chinese and English doc Current Field replaceable
3406Y001Active Optical Cable Assembly,200Gb/s to 2x100Gb/s, QSFP56 to 2xQSFP56,IB HDR, 200Gpbs, LSZH, black pulltab,0.005km Current Field replaceable
0632Y074GPU Card,NVIDIA L20 GPU Accelerator,PN:900-2G133-00A0-000 / 48GB GDDR6 Memory / 864GB/s Memory Bandwidth /PCIE 4.0 x16-10DE-26BA-1 /350W,No NVLink,English doc,Dual slot,Passive Current Field replaceable
0632Y075GPU Card,NVIDIA L2 GPU Accelerator,PN:900-2G193-0030-000/24GB GDDR6 Memory/ 300GB/s peak Memory Bandwidth/ PCIE 4.0 x16-10DE-27B6-1,72W/ HHHL, single-slot/Passive cooling,English doc,No Cable Current Field replaceable
3406Y003Active Optical Cable Assembly,200GbE, QSFP56,IB HDR, 200Gb/s, LSZH, black pulltab,0.005km Current Field replaceable
3406Y033High Speed Transceiver,SFP28,850nm,25G,-8.4dBm,2.4dBm,-10.3dBm,LC,MM,0.1km,sont split Current Field replaceable
3406Y023High Speed Transceiver,QSFP56,850nm,200Gbps,-5.9dBm,4dBm,-4.4dBm,MPO12/UPC,MM,0.1km,8636 Current Field replaceable
3406Y012High Speed Transceiver,OSFP,850nm,400Gbps,-4.6dBm,4dBm,-4.4dBm,MPO-12/APC,MM,0.05km,OM4 Dedicated to IB NDR HCA Current Engineer replace
0603Y037Other Cards,HBA Card LPe36002-AP,FC dual Ports-64Gb/s,PCIE 4.0 x8-Vendor ID 10df-Device ID f400-2-Subvendor ID 10df-Subdevice ID f404,Chinese and English doc,half width half length Current Field replaceable
06310158Network Card,100 Gigabit,64bit,QSFP28(without Optical Transceiver),2 Ports,PCIE 3.0 x16-Vendor ID 15b3-Device ID 1017-2-Subvendor ID 15b3-Subdevice ID 0007,No Driver CD Current Field replaceable
06310132Network Card,XXV710DA2G1P5 948661-25 Gigabit,64bit,SFP28,2 ports,PCIE 3.0 X8-8086-158b-2,No Driver CD Current Field replaceable
06310148Network Card,25 Gigabit,64bit,SFP28(without Optical Transceiver),2 Ports,PCIE 3.0 x8-14e4-16d7-2,No Driver CD Current Field replaceable
0631Y021Network Card,25 Gigabit,64bit,SFP28,2 ports,PCIE 3.0 x8-1924-0b03-2,No Driver CD Current Field replaceable
0257Y512PCIe-NIC Card,2288H V6-32dimm,MCX631102AN-ADAT,PCIe-NIC Card,25 GE,64bit,SFP28,dual port,PCIE 4.0 x8-Vendor ID 15b3-Device ID 101f-2-Subvendor ID 15b3-Subdevice ID 0001 Current Field replaceable
0257Y357PCIe-NIC Card,2288H V6,MCX512A-ACAT,Network Card,25Gb Optical Interface(MCX512A-ACAT),2-Port,SFP28(without Optical Transceiver),PCIE 3.0 x8-15b3-1017-2 Current Field replaceable
0257Y475PCIe-NIC Card,2258 V7,900-9D3B6-00SC-EA0,100Gb/s,64bit,QSFP112,2 Port,PCIE 5.0 X16-15b3-a2dc|c2d5-3-Subvendor ID 15B3-Subdevice ID 0035,NVIDIA BlueField B3210E Crypto Disabled-Single-Slot-32GB DDR5(with NCSI wire) Current Field replaceable
0257Y498PCIe-NIC Card,2258 V7,MCX623106AN-CDAT,NIC-100Gb(MCX623106AN-CDAT)-2 Ports-QSFP56(without Optical Transceiver)-PCIE 4.0 x16-15b3-101d-2,With driver pack Current Field replaceable
P/NDescription / SpecificationStatus
0257Y104PCIe-network adapter-2288H V6-X710DA2OCPV3-network adapter-2*10GE-64bit-SFP+(without optical module)-2 ports-PCIE 3.0 x8-8086-1572-2-OCP 3.0-with driver package Current
0257Y105PCIe-network adapter-2288H V6-X710T2LOCPV3-X710T2LOCPV3 Ethernet adapter-2*10GE(Intel X710)-dual-port-RJ45-PCIE 3.0 x8-8086-15FF-2-with driver package-OCP Current
0257Y107PCIe-network adapter-2288H V6-E810XXVDA2OCP3G-Ethernet adapter-25GE(Intel E810)-dual-port-SFP28-PCIE 4.0 x8-Vendor ID 8086-Device ID 159b-2-Subvendor ID 8086-Subdevice ID 0005-with driver package-OCP Current
0257Y108PCIe-network adapter-2288H V6-BCM957414N4140C-Ethernet adapter-2*25GE(Broadcom BCM57414)-dual-port-SFP28-PCIE 3.0 x8-14e4-16d7-2,OCP 3.0-with driver package Current
0257Y131PCIe-network adapter-2288H V6-BCM957508-N2100G-network adapter-100 Gigabit-64bit-QSFP28-2 ports-PCIE 4.0 x16-14e4-1750-2,OCP-with driver package Current
0302Y054manufactured board-JDM-Public Module-BC53ETHF-XC310 GE350-T2 OCP3.0 Ethernet adapter-2*GE(I350)-dual-port-RJ45,PCIE 2.1 x4-Vendor ID 8086-Device ID 1521-2-Subvendor ID 1f24-Subdevice ID 200b-1*4 Current
0302Y055manufactured board-JDM-Public Module-BC53ETHB1-XC382 OCP3.0 Ethernet adapter-25GE(CX5)-dual-port-SFP28(optical module not included)-PCIE 3.0 X8-Vendor ID 15b3-Device ID 1017-2-Subvendor ID 1f24-Subdevice ID 200c-1*4 Current
0302Y237manufactured board-JDM-Public Module-BC53ETHH-XC331 OCP3.0 Ethernet adapter-10GE(BCM57416)-dual-port-RJ45-PCIE 3.0 X8-Vendor ID 14e4-Device ID 16d8-2-Subvendor ID 1f24-Subdevice ID 2010-1*3 Current
0302Y238manufactured board-JDM-Public Module-BC55ETHA-XC385 OCP3.0 Ethernet adapter-25GE(CX6-Lx)-dual-port-SFP28(optical module not included)-PCIE 4.0 X8-Vendor ID 15b3-Device ID 101f-2-Subvendor ID 1f24-Subdevice ID 2011-1*4 Current
0302Y434manufactured board-JDM-Public Module-BC53ETHI-XC386 OCP3.0 Ethernet adapter-25GE(BCM57414)-dual-port-SFP28(optical module not included)-PCIE 3.0 X8-Vendor ID 14e4-Device ID 16d7-2-Subvendor ID 1f24-Subdevice ID 2013-1*4 Current
0302Y435manufactured board-JDM-Public Module-BC53ETHJ-XC333 OCP3.0 Ethernet adapter-10GE(BCM57412)-dual-port-SFP+(optical module not included)-PCIE 3.0 X8-Vendor ID 14e4-Device ID 16d6-2-Subvendor ID 1f24-Subdevice ID 2014-1*4 Current
0631Y023-002network adapter-2*25GE-64bit-SFP28(without optical module)-2 Ports-PCIE 3.0 x8-14e4-16d7-2-without driver-OCP 3.0 Current
0302Y085manufactured board-JDM-Public Module-BC53ETHG-XC383 OCP3.0 Ethernet adapter-10GE(CX-4 Lx)-dual-port-SFP+(optical module not included)-PCIE 3.0 X8-Vendor ID 15b3-Device ID 1015-2-Subvendor ID 1f24-Subdevice ID 200d-1*4 EOM
0631Y004Network Card,25Gb/s,64bit,SFP28,2 ports,PCIE 4.0 x8-Vendor ID 8086-Device ID 159b-2-Subvendor ID 8086-Subdevice ID 0005,No Driver CD,OCP Current Field replaceable
0631Y023Network Card,2*25GE,64bit,SFP28(without Optical Transceiver),2 Ports,PCIE 3.0 x8-14e4-16d7-2,No Driver CD,OCP 3.0 Current Field replaceable
0631Y043Network Card,100 Gigabit,64bit,QSFP28,2 ports,PCIE 4.0 x16-14e4-1750-2,No Driver CD,OCP Current Field replaceable
0257Y312PCIe-NIC Card,2288H V7,MCX623436AN-CDAB,OCP Network card-100 Gigabit-64bit-QSFP28-2 ports-PCIE 4.0 x16-15b3-101d-1|2|4-without driver-without optical module-OCP 3.0,Without driver pack Current Field replaceable
P/NDescription / SpecificationStatus
02313ADYfunction module-TS200-2280-BC11TPMC02-TPM2.0 card(SPI)-China dedicated Current
02313APLfunction module-TS200-2280-BC11TPMA02-TPM2.0 card(SPI)-international dedicated Current
02313KFCfunction module-2488H V6-BC11TPMA07-TCM card(SPI) Current
03028HYWManufactured Board,TaiShan 200 (Model 2280),BC11TPMD,TPM2.0 Card(SPI), China Dedicated,5*4 Current Engineer replace
03024QEJManufactured Board,2288H V5,BC11TPMB,TCM Card(SPI),5*4 Current Engineer replace
03024QEHManufactured Board,2288H V5,BC11TPMA,TPM2.0 Card(SPI), Overseas Dedicated,5*4 Current Engineer replace
P/NDescription / SpecificationStatus
0302012403manufactured board-2288H V7-BC15HBBB-12*3.5 inch SAS/SATA pass-through(incl. 4*NVMe)drive backplane-1*2 NONE
0302012404manufactured board-2288H V7-BC15HBBA-8*2.5 inch SAS/SATA standard drive backplane-1*2 NONE
0302012406manufactured board-2288H V7-BC15NHBB-24*NVMe(incl. 8*SAS/SATA)pass-through drive backplane-1*2 NONE
0302012451manufactured board-2288H V7-BC15NHBA-4*SAS+8*NVMe pass-through drive backplane-1*2 NONE
0302013602manufactured board-2288H V7-BC15HBBC-24*2.5 inch SAS/SATA pass-through drive backplane-1*2 NONE
0302Y125manufactured board-2288H V7-BC15NHBI-8*SAS/SATA+16NVME pass-through drive backplane-1*2 NONE
0302Y650manufactured board-2258 V7-BC15NHBR-12*3.5 inch SAS/SATA/NVMe drive backplane-1*2 NONE
0302Y676manufactured board-2258 V7-BC15NHBS-8*2.5 inch SAS/SATA/NVMe hard Raid drive backplane-1*2 NONE
0302Y683manufactured board-2258 V7-BC15HBBS-IO3 4*NVMe drive backplane-1*4 NONE
P/NDescription / SpecificationStatus
02313XSFserver platinum 900W 2.0 versionAC power supply-ST(model PAC900S12-B2,interface IEC 320-C14) Current
0231Y019server platinum 2000W 2.0 versionAC power supply(model PAC2000S12-B1,interface IEC 320-C14) Current
0231Y020server DC power supply-PDC1200S12-CF-68mm-1200W-air-cooled(requires DC power cord)(model PDC1200S12-CF,interface Phoenix SPT 5/3-H-7,5-ZB model crimp terminal) Current
0231Y021HVDC1500WB power supply module(model PHD1500S12-B2,interface Rongfeng RF-203 high-voltage input terminal) Current
0231Y0233000W titanium AC power supply(model PAC3000S12-T1,interface IEC 320-C20) Current
0231Y025server titanium 2000W AC power supply module(model PAC2000S12-T1,interface IEC 320-C14) Current
0231Y033server platinum 1500W 2.0 versionAC power supply(model PAC1500S12-B1,interface IEC 320-C14) Current
0231Y265900W titanium AC power supply(model PAC900S12-T1,interface IEC 320-C14) Current
0231Y493server DC power supply-68mm-1200W-air-cooled(incl. DC power cord)(model PDC1200S12-CF1,interface Phoenix SPT 5/3-H-7,5-ZB model crimp terminal) Current
0231Y017Function Module,PAC900S12-B2,Server Platinum 900W Version 2.0 AC power supply Current Field replaceable
P/NDescription / SpecificationStatus
0255Y695SSD module-Servers-M.2 SSD-SATA 6Gb/s-240GB-80.0mm * 22.0mm * 3.58 mm(hot-swappable)-ER3 series Current
0255Y696SSD module-Servers-M.2 SSD-SATA 6Gb/s-240GB-80.0mm * 22.0mm * 3.58 mm(non-hot-swappable)-ER3 series Current
0255Y697SSD module-Servers-M.2 SSD-SATA 6Gb/s-480GB-80.0mm * 22.0mm * 3.58 mm(hot-swappable)-ER3 series Current
0255Y698SSD module-Servers-M.2 SSD-SATA 6Gb/s-480GB-80.0mm * 22.0mm * 3.58 mm(non-hot-swappable)-ER3 series Current
0255YBWESSD module-Servers-M.2 SSD-NVMe PCIe-1920GB-80.0mm * 22.0mm * 3.58 mm(non-hot-swappable)-PJ1 series Current
0255YCULSSD module-Servers-M.2 SSD-NVMe PCIe-960GB-80.0mm * 22.0mm * 3.58 mm(non-hot-swappable)-PJ1 series Current
0255YEUUSSD module-Servers-M.2 SSD-NVMe PCIe-1920GB-80.0mm * 22.0mm * 3.58 mm(non-hot-swappable)-PJ1 series Current
0255YFBASSD module-Servers-M.2 SSD-SATA 6Gb/s-480GB-80.0mm * 22.0mm * 3.58 mm(hot-swappable)-ER3 series Current
0255YFBPSSD module-Servers-M.2 SSD-SATA 6Gb/s-480GB-80.0mm * 22.0mm * 3.58 mm(non-hot-swappable)-ER3 series Current
0255YFDHSSD module-Servers-M.2 SSD-NVMe PCIe-480GB-80.0mm * 22.0mm * 3.58 mm(non-hot-swappable)-PM9A3 series Current
0255YGFSSSD module-Servers-M.2 SSD-NVMe PCIe-960GB-80.0mm * 22.0mm * 3.58 mm-PJ1 series Current
90010339Liquid Manufactory Auxiliaries,Thermal Grease,X-23-7868-2D,Thermal Conductivity 3.6W/mK / 6.0W/mK,2g,Gap filling thermal conductive for customer use,1ml Current Engineer replace
03025VYYManufactured Board,TaiShan 2280 V2,BC82LCIA,Left Customer Interface,4*2 Current Engineer replace
02312YJFFunction Module,TaiShan 200 (Model 2280),BC2M5ERISE,Unpacking Inspection Module Current Engineer replace
0258Y047IO Extended Module-PCIE,2288H V7,BC1M07PRUB,1*16X SLOT(PCIE5.0)+2*8X SLOT(PCIE4.0)-IO1&2 module,Spare Parts Current Engineer replace
0258Y046IO Extended Module-PCIE,2288H V7,BC1M02PRUE,1*16X SLOT(PCIE4.0)-SLOT2-IO1&2 module,Spare Parts Current Engineer replace
0258Y013IO Extended Module-PCIE,2288H V7,BC1M01PRUC,2*16X SLOT(PCIE5.0)-SLOT1&2-IO1&2 module Current Engineer replace
0258Y044IO Extended Module-PCIE,2288H V7,BC1M02PRUC,2*16X SLOT(PCIE5.0)-SLOT1&2-IO1&2 module,Spare Parts Current Engineer replace
0258Y030IO Extended Module-PCIE,2288H V7,BC1M02PRUR,2*16X SLOT(PCIE5.0)-SLOT2&3-IO1&2 module for GPU Current Engineer replace
0258Y007IO Extended Module-Hard Disk,2288H V7,BC1M03HBBF,2*3.5" Rear Hard Disk Backplane Module Current Engineer replace
0258Y006IO Extended Module-Hard Disk,2288H V7,BC1M02HBBE,2*2.5" Rear Hard Disk Backplane Module+1*16 Riser card Current Engineer replace
0258Y049IO Extended Module-Hard Disk,2288H V7,BC1M03HBBE,2*2.5" Rear Hard Disk Backplane Module+1*16 Riser card,Spare Parts Current Engineer replace
0258Y016IO Extended Module-PCIE,2288H V7,BC1M01PRUB,1*16X SLOT(PCIE5.0)+2*8X SLOT(PCIE4.0)-IO1&2 module Current Engineer replace
0258Y015IO Extended Module-PCIE,2288H V7,BC1M01PRUE,1*16X SLOT(PCIE4.0)-SLOT2-Riser1&2 module Current Engineer replace
0302Y360Manufactured Board,2258 V7/2258H V7/1258H V7,BC15MASA,2258 V7/2258H V7/1258H V7 AMD Server Board,1*1 Current Field replaceable
0302Y364Manufactured Board,2258 V7,BC15MSMB,AMD Server ,inner M.2 adapter, support SATA/PCIe,1*4 Current Field replaceable
0258Y189IO Extended Module-PCIE,2258 V7,BC1M05PRUF,1*16X SLOT(PCIE4.0)-RISER3 PSU module for AMD 12HDD,only slot8 Current Engineer replace
0258Y186IO Extended Module-Hard Disk,2258 V7,BC1M03NHBC,Rear 4*2.5" Hard Disk Backplane Module for NVME for AMD Current Engineer replace
0258Y272IO Extended Module-PCIE,2258H V7,BC1M06PRUI,2*8X SLOT(PCIE4.0)-two cards Riser3 PSU Module for AMD Slot9 and Slot10 Current Engineer replace
0258Y319IO Extended Module-PCIE,2258H V7,BC1M10PRUI,2*8X SLOT(PCIE4.0)-two cards Riser3 PSU Module for AMD Slot9 and Slot10,Spare Parts Current Engineer replace
0258Y192IO Extended Module-PCIE,2258 V7,BC1M08PRUF,1*16X SLOT(PCIE4.0)-RISER3 PSU module for AMD 12HDD,Spare Parts Current Engineer replace
0258Y390IO Extended Module-PCIE,2158H V8,BC1M01PRUCC,1*16X SLOT(PCIE5.0)-SLOT2-IO1&2 module Current Engineer replace
0258Y366IO Extended Module-PCIE,2258 V7,BC5PRVB01,16X SLOT5(PCIE5.0 SINGLE HOST-6460C)+16X SLOT6(PCIE5.0)-IO2 module Current Engineer replace
0258Y365IO Extended Module-Hard Disk,2258 V7,BC1M01HBBS,Rear 4*2.5" Hard Disk Backplane Module for NVMe,PCIE5.0 Current Engineer replace
0258Y188IO Extended Module-PCIE,2258 V7,BC1M04PRUF,2*16X SLOT(PCIE4.0)-RISER3 PSU module for AMD 12HDD with IO HDD module Current Engineer replace
0258Y187IO Extended Module-PCIE,2258 V7,BC1M03PRUF,2*16X SLOT(PCIE4.0)-RISER3 PSU module for AMD 8HDD Current Engineer replace
0258Y264IO Extended Module-PCIE,2258 V7,BC1M08PRUB,2*8X SLOT(PCIE4.0)-IO1&2 module Current Engineer replace
0258Y480IO Extended Module-Hard Disk,2258 V7,BC1M03HBBS,Rear 4*2.5" Hard Disk Backplane Module for NVMe,PCIE5.0(DIDI 1P) Current Engineer replace
0258Y381IO Extended Module-Hard Disk,2258 V7,BC1M02HBBS,Rear 4*2.5" Hard Disk Backplane Module for NVMe,PCIE5.0 Current Engineer replace
0258Y437IO Extended Module-PCIE,2258H V7,BC1M07PRUI,1*8X SLOT(PCIE4.0)-one cards Riser3 PSU Module for AMD Slot9 Current Engineer replace
0258Y512IO Extended Module-Hard Disk,2258 V7,BC1M06HBBS,Rear 2*2.5" Hard Disk Backplane Module for NVMe,PCIE5.0 Current Engineer replace
0258Y233IO Extended Module-PCIE,2258H V7,BC1M04PRUI,2*8X SLOT(PCIE4.0)-two cards Riser3 PSU Module for AMD Slot7 and Slot8 Current Engineer replace
0258Y497IO Extended Module-PCIE,2258 V7,BC1M02PRVB,16X SLOT5(PCIE5.0)+16X SLOT6(PCIE5.0)-IO2 module,Carrying BF3 card air duct Current Engineer replace
0258Y474IO Extended Module-PCIE,2288H V7,BC1M08PRUC,1*16X SLOT(PCIE5.0)-SLOT2&5-IO1&2 module Current Engineer replace
0258Y496IO Extended Module-Hard Disk,2258 V7,BC1M04HBBS,Rear 4*2.5" Hard Disk Backplane Module for NVMe,PCIE5.0, Xiecheng configuration Current Engineer replace
0258Y352IO Extended Module-PCIE,2258H V7,BC1M06PRUI,2*8X SLOT(PCIE4.0)-two cards Riser3 PSU Module for AMD Slot9 and Slot10 Current Engineer replace
0258Y271IO Extended Module-PCIE,2258H V7,BC1M05PRUI,4*8X SLOT(PCIE4.0)-four cards Riser3 Module-for AMD Current Engineer replace
0258Y193IO Extended Module-PCIE,2288H V7,BC1M03PRUC,2*16X SLOT(PCIE5.0)-SLOT1&2-IO1&2 module for full height half length single slot GPU Card Current Engineer replace
0258Y191IO Extended Module-PCIE,2258 V7,BC1M07PRUF,2*16X SLOT(PCIE4.0)-RISER3 PSU module for AMD 12HDD with IO HDD module,Spare Parts Current Engineer replace
0258Y190IO Extended Module-PCIE,2258 V7,BC1M06PRUF,2*16X SLOT(PCIE4.0)-RISER3 PSU module for AMD 8HDD,Spare Parts Current Engineer replace
P/NDescription / SpecificationStatus
04052259Power cord,China AC Power 250V2.5A,2.0m,PISM,227IEC53-0.75^2(3C),C5SF,250V,2.5A,Black Current Engineer replace
04051080Power cord,South Africa AC Power 250V10A,3m,PMAM,H05VV-F-1.0mm^2(3C),C13SF,250V,10A,Black Current Engineer replace
04041119Power Cable,Switzerland AC Power Cable 250V10A,3.0m,PJSM ,H05VV-F-1.0mm^2(3C),C13SF,Black Current Engineer replace
04050517Power Cable,China AC Power Cable 250V10A,2.0m,PISM,227IEC53(RVV)1.0mm^2(3C),C13SF,Black Current Engineer replace
0415G005Power cord,China AC Power 250V10A,2.0m,C14SM,227IEC53-1.0^2(3C),C13SF,PDU Cable Current Engineer replace
0405G02CPower Cords Cable,China AC Power 250V10A,0.8m,C14SM,227IEC53 1.0^2(3C),C13SF,PDU Cable Current Engineer replace
0405G02DPower Cords Cable,Japan AC Power 250V12A,1.8m,C14SM,HVCTF 1.25^2(3C),C13SF,PDU Cable Current Engineer replace
04050955Power Cords Cable,China AC Power,250V10A,1.5m,PISM,227IEC53(RVV)1.0mm^2(3C),C13SF,250V,10A,Black Current Engineer replace
0405G02FPower Cords Cable,Australia AC Power 250V10A,1.8m,C14SM,H05VV-F-1.0^2(3C),C13SF,PDU Cable Current Engineer replace
04041117Power Cable,Britain AC Power Cable 250V10A,3.0m,PGAM ,H05VV-F-1.0mm^2(3C),C13AF-L,Black Current Engineer replace
0405G02HPower Cords Cable,Korea AC Power 250V10A,1.8m,C14SM,H05VV-F-1.0^2(3C),C13SF,PDU Cable Current Engineer replace
0405G02KPower Cords Cable,Denmark AC Power 250V10A,3m,PKSM,H05VV-F-3*1.0^2(3C),C13SF,Black Current Engineer replace
0405G028Power Cords Cable,Korea AC Power 250V10A,3m,PFSM,H05VV-F 3*1.0^2(3C),C13SF,Black Current Engineer replace
04050588Power cord,China AC Power Cable250V10A,1.5 m,C14SM,(227IEC53(RVV)1.0mm^2(3C)),C13SF,250V,10A,White,PDU Cable Current Engineer replace
0405G029Power Cords Cable,North America AC Power 250V10A,1.8m,C14SM,SJT 18AWG(3C),C13SF,PDU Cable Current Engineer replace
04050784Power Cords Cable,China AC Power Cable,250V16A,2m,C14SM,227IEC53-1.0^2(3C),C13SF,Yellow Current Engineer replace
04051035Power cord,India AC Power 250V6A,3m,PM-IIAM,IS 694-1.0^2(3C),C13 SF,250V,6A,Black Current Engineer replace
04050188Power Cords Cable,China AC Power 250V10A,1.5m,C14SM,227IEC53(RVV)1.0mm^2(3C),C13SF,PDU Cable Current Engineer replace
04020728Power Cable,America AC Power Cable,125V10A,3.0m,PBSM,18SJT(3C),C13SF,Black Current Engineer replace
04042698Power Cords Cable,China AC Power 250V10A,15.0m,PISM,227IEC53-1.0^2(3C),C13SF,Black Current Engineer replace
04042697Power Cords Cable,China AC Power 250V10A,10.0m,PISM,227IEC53-1.0^2(3C),C13SF,Black Current Engineer replace
04042699Power Cords Cable,China AC Power 250V10A,20.0m,PISM,227IEC53-1.0^2(3C),C13SF,Black Current Engineer replace
04041120Power Cable,Italy AC Power Cable 250V10A,3.0m,PLSM,H05VV-F-1.0mm^2(3C),C13SF,Black Current Engineer replace
04047785Power Cords Cable,Argentina AC Power 250V10A,3.0m,PISM,H05VV-F-1.0mm^2(3C),C13SF,Black Current Engineer replace
04051020High Speed Cable,Internal Mini SAS HD Cable,0.75m,Internal Mini SAS HD R/A,8*(1P*30AWG+ 2*Drain)+8C*30AWG,Internal Mini SAS HD STR,R/A-STR Current Engineer replace
04052137Power cord,Taiwan AC 125V11A,3.0m,PBSM,HVCTF 3*1.25mm2,C13SF,125V,11A,Black,BSMI Current Engineer replace
04040888Power Cords Cable,Australia AC Power Cable,250V 10A,3.0m,PISM,H05VV-F-1.0mm^2(3C),C13SF,Black Current Engineer replace
04040889Power cord,BS546 250V10A,3.0m,PM-IAM,H05VV-F-1.5mm^2(3C),C13SF,250V,10A,Black Current Engineer replace
0405G019Power Cords Cable,Europe AC 250V10A,1.8m,C14SM,H05VV-F- 3*1.00^2,C13SF,PDU Cable Current Engineer replace
04050373Power cord,China AC Power Cable250V10A,1.0m,C14SM,(227IEC53(RVV)-1.0mm^2(3C)),C13SF,Black,PDU Cable Current Engineer replace
04041056Power cord,Europe AC Power Cable,250V10A,3.0m,PFSM,(H05VVF 1.0^2(3C)),C13SF,250V,10A,BLack Current Engineer replace
04050139Power Cords Cable,China AC Power Cable,250V10A,3m,PISM,227IEC53-1.0^2(3C),C13SF,Black Current Engineer replace
04150258Power Cable,Brazil AC Power Cable 250V10A,3.0m,PNSM ,H05VV-F-1.0mm^2(3C),C13SF,Black Current Engineer replace
04040887Power Cable,Japan AC Power Cable 125V12A,3.0m,PBSM,HVCTF-1.25mm^2(3C),C13SF,Black Current Engineer replace
14130923Optical Cable Parts,MPO/PC,MPO/PC,MULTI-MODE,15m,8 CORES,0m/0m,GJFH-8A1A.2(OM3),3.5MM,LSZH,60mm MPO,Bending insensitive Current Engineer replace
04050847Power cord,China AC Power Cable,250V10A,6.0m,C14SM,(227IEC53-1.0^2(3C)),C13SF,250V,10A,Black,PDU Cable Current Engineer replace
04051858Power cord,China AC Power Cable 250V10A,3.0m,PISM,227IEC53-1.0^2(3C),C13SF,250V,10A,Yellow Current Engineer replace
04041104Power Cords Cable,China AC Power 250V10A,3.0m,PISM,227IEC53-1.0^2(3C),C13SF,Black Current Engineer replace
04050846Power cord,China AC Power Cable,250V10A,3.0m,C14SM,(227IEC53-1.0^2(3C)),C13SF,250V,10A,Black,PDU Cable Current Engineer replace
04050206Power Cable,China AC Power Cable 250V10A,1.0m,PISM,227IEC53(RVV)1.0mm^2(3C),C13SF,Black Current Engineer replace
04040890Power Cable,Britain AC Power Cable 250V10A,3.0m,PGAM ,H05VV-F-1.0mm^2(3C),C13SF,Black Current Engineer replace
04051018High Speed Cable,Internal Mini SAS HD Cable,0.63m,Internal Mini SAS HD R/A,8*(1P*30AWG+ 2*Drain)+8C*30AWG,Internal Mini SAS HD STR,R/A-STR Current Engineer replace
0405Y020High Speed Cable,HS Cable Slimline-2*mini SAS HD,0.9m&0.8m,Slimline X8 STR,2*((31AWG*1Pair+31AWG*2Drain)*8+31AWG*1Pair*4),2*Internal mini SAS HD R/A,Slimline-2*mini SAS HD Current Engineer replace
04051403High Speed Cable,100G EDR QSFP28 Passive High Speed Cable,1m,QSFP28,CC8P0.4B(S),QSFP28,IB-Mellanox,LSZH Current Engineer replace
14270054BTB Connector module,74,UBC 8X curved,250mm,0.16mm,10mm,3200MB/s,1.57mm,Wire mounting,Y Current Engineer replace
0405Y011High Speed Cable,25G SFP28 Passive High Speed Cable,3m,SFP28,CC2P0.254B(S),SFP28 Current Engineer replace
0405Y017High Speed Cable,HS Cable Slimline-2*mini SAS HD,0.8m&0.7m,Slimline X8 STR,2*((31AWG*1Pair+31AWG*2Drain)*8+31AWG*1Pair*4),2*Internal mini SAS HD R/A,Slimline-2*mini SAS HD Current Engineer replace
04051074Power cord,India AC Power 250V 16A,3m,PM-IIIAM,IS 694-1.5mm^2(3C),C19SF,250V,16A,Black Current Engineer replace
0405Y010High Speed Cable,25G SFP28 Passive High Speed Cable,1m,SFP28,CC2P0.254B(S),SFP28 Current Engineer replace
04050422Power Cords Cable,China /Europe/America/Korea Multiple Certificate AC Power 250V16A,3.0m,C20SM,H05VV-F-1.5mm^2(3C) +14SJT3(3C),C19SF,PDU Cable Current Engineer replace
04051079Power cord,South Africa AC Power 250V16A,3m,PMAM,H05VV-F-1.5mm^2(3C),C19SF,250V,16A,Black Current Engineer replace
04152747Power Cable,1.8m,HVDC Straight Female,227IEC53(RVV)1.0mm^2(3C),C14SM Current Engineer replace
04051113IT Equipment Cable,Serial Port Cable,3m,D9 FM,CC2P0.32PWG1U,MP8-I Current Engineer replace
04052442High Speed Cable,200G HDR QSFP56 Passive Copper cable,1m,QSFP56,QSFP56,IB-Mellanox,LSZH Current Engineer replace
0405Y009High Speed Cable,10G Passive SFP+ Cable,5m,(SFP+20M),(CC2P0.4B),(SFP+20M),LSFRZH For Indoor,ETH 10GbE,Y Current Engineer replace
0405Y008High Speed Cable,10G Passive SFP+ Cable,1m,(SFP+20M),(CC2P0.254B),(SFP+20M),LSFRZH For Indoor,ETH 10GbE,LSZH Current Engineer replace
0405Y128Power cord,Japan AC Power 250V15A,3.0m,NEMA5-15PSM,HVCTF-2.0mm^2(3C)black,C19SF,125V,15A Current Engineer replace
0405Y007High Speed Cable,10G SFP+ High Speed Cable,3m,SFP+20M,CC2P0.254B(S),SFP+20M,LSFRZH For Indoor,ETH 10GbE,LSZH Current Engineer replace
04043396Power Cords Cable,China AC Power 250V16A,3.0m,PIAM,227IEC53-2.5^2(3C),C19SF,Black Current Engineer replace
0415Y642Power Cable,250V-16A 3m,2.5mm^2(3C),black,C21,2.5mm^2(3C),C20 Current Engineer replace
04045184Power Cords Cable,Australia AC Power 250V16A,3.0m,PISM,H05VVF-2.5^2(3C),C19SF,Black Current Engineer replace
04051418Power cord,China AC Power 250V16A,30.0m,PIAM,227IEC53-2.5^2(3C),C19SF,250V,16A,Black Current Engineer replace
04080975Monitor&Alarm Cable,Signal cable,0.55m,H2X8(2.0),16*UL1685 28AWG,H2X8(2.0),Front HDDboard signal cable-2/4pin sheild Current Engineer replace
04052139Power cord,Taiwan AC 125V15A,3.0m,PBSM,VCTFK3*2.0mm2(3C),C19SF,125V,15A,Black,BSMI Current Engineer replace
04050189Power Cords Cable,China AC Power 250V 16A,1.0m,C20SM,227IEC53x1.5^2(3C),C19SF,PDU Cable Current Engineer replace
04044598Power Cords Cable,Europe AC Power 250V16A,3.0m,PFAM,H05VVF-1.5^2(3C),C19SF,Black Current Engineer replace
04044597Power cord,BS546 250V16A,3.0m,PM-IAM,H05VV-F-1.5mm^2(3C),C19SF,250V,16A,Black Current Engineer replace
04050850Power Cords Cable,Britain AC Power Cable,250V13A,3.0m,PG AM,H05VV-F-1.5mm^2(3C),C19 SF,Black Current Engineer replace
04151188Power Cable,1.5m,HVDC Straight Female,227IEC53(RVV)1.0mm^2(3C) Current Engineer replace
04050856Power Cords Cable,Australia AC Power 250V16A,3.0m,C20SM,H05VV-F-1.5^2(3C),C19SF,PDU Power Cord Current Engineer replace
04150259Power Cords Cable,Brazil AC Power 250V16A,3.0m,PN-ISM ,H05VVF-1.5^2(3C),C19SF,Black Current Engineer replace
04050855Power Cords Cable,Japan AC Power 250V15A,3.0m,C20SM,VCTF-2.0^2(3C),C19SF,PDU Power Cord Current Engineer replace
04044603Power Cords Cable,North America AC Power 125V20A,3.0m,NEMA5-20PAM,12SJT(3C),C19SF,Black Current Engineer replace
04080980Monitor&Alarm Cable,Signal cable,0.2m,H2X9(2.0),14*28UL1685B/14*28UL1685B(S),H2X9(2.0) Current Engineer replace
04051322Power cord,Switzerland AC Power Cable,3m,PJ-II SM,H05VV-F-1.5mm^2(3C),C19SF,250V,16A Current Engineer replace
0405Y023High Speed Cable,HS Cable Slimline-2*mini SAS HD,0.65m&0.2m&0.35m,Slimline X8 STR,2*((31AWG*1Pair+31AWG*2Drain)*8+31AWG*1Pair*4),Internal mini SAS HD R/A+Internal mini SAS HD STR,Slimline-3*Mini SAS HD Current Engineer replace
14270058BTB Connector module,184pin-74pin*2,UBCDD 16X vertical plug,UBC 8X right-angle plug*2,0.6&0.65m,0.16mm,10mm,32000MB/s,1.57mm,Wire mounting,Y Current Engineer replace
0405Y019High Speed Cable,HS Cable Slimline-2*mini SAS HD,1.0m&0.9m,Slimline X8 STR,2*((31AWG*1Pair+31AWG*2Drain)*8+31AWG*1Pair*4),2*Internal mini SAS HD R/A,Slimline-2*mini SAS HD Current Engineer replace
04150441Power Cable,3.5m,4mm^2,2*T4^2GY,H07Z-K-4^2BL+H07Z-K-4^2B,2*T4^2GY,LSZH Current Engineer replace
04152464Power Cable,0.5m,4mm^2,(OT6-4),(H07Z-K-4^2G&Y),(OT6-6),LSZH,YES Current Engineer replace
1427Y040BTB Connector module,74,UBC 8X curved,100mm,0.16mm,10mm,32000MB/s,1.57mm,Wire mounting,Y Current Engineer replace
04080974Monitor&Alarm Cable,Signal cable,0.45m,H2X6(2.0),12*UL1685 28AWG,H2X6(2.0),Fan board signal cable-2/4pin sheild Current Engineer replace
0415Y029Power Cable,0.65m&0.63m,2*6.0mm^2,red/black,80A R/A easy connector,10UL1015RE+10UL1015BL,2*OT6-4 Current Engineer replace
04052311IT Equipment Cable,Signal Cable,0.38m,(H2X25(1.0)),4*(1P*30AWG+1*Drain)+5*(1P*30AWG)+3*30AWG Shield+22*UL1571 30AWG),(H2X25(1.0) Current Engineer replace
04153757Power Cable,0.52m,black,80A R/A easy connector,5*18UL2651,80A R/A easy connector Current Engineer replace
0415Y125Power Cable,0.25m,Black,H2X6(3.0),12*18UL1569B/1*28UL1685B,(H2X6(3.0)/1X4(2.0)) Current Engineer replace
1427Y071BTB Connector module,74pin-36pin*2,UBC 8X curved,600mm&650mm,0.16mm,10mm,1536MB/s,Wire mounting,Y Current Engineer replace
1427Y073BTB Connector module,74pin-36pin,UBC 8X curved,Internal mini SAS HD R/A,850mm,0.16mm,10mm,1536MB/s,Wire mounting,NULL Current Engineer replace
1427Y148BTB Connector module,74,UBC 8X curved,900mm,0.16mm,10mm,22500MB/s,1.57mm,Wire mounting,Y Current Engineer replace
1427Y149BTB Connector module,74,Slimline 8X vertical,950&900mm,0.16mm,10mm,22500MB/s,1.57mm,Wire mounting,Y Current Engineer replace
0415Y025Power Cable,0.20m,H2X6(3.0),12*18UL1569B,2*H2X3(4.2),PCIe12-2*PCIe6 Current Engineer replace
04052385High Speed Cable,Mini SAS HD 4i High Speed Cable,0.2m&0.35m,Internal Mini SAS HD STR,8*(1P*30AWG+ 2*Drain)+8C*30AWG,2*Internal Mini SAS HD STR,SAS HD To 2*SAS HD Current Engineer replace
0405Y075IT Equipment Cable,Signal Cable,0.25&0.15m,(H2X15(1.0)),(18*28UL1685),2*(H2X6(2.0))+(H2X4(2.0)) Current Engineer replace
0408Y036Monitor&Alarm Cable,Signal cable,0.40m,H2X8(2.0),10*28UL1685B+3*28UL1569B+2*28UL1685B(S),H2X8(2.0),Front HDD board signal cable-2/4pin sheild Current Engineer replace
1427Y131BTB Connector module,74pin-36pin,UBC 8X Straight,1*Internal mini SAS HD R/A,750mm,0.16mm,10mm,1536MB/s,Wire mounting,NULL Current Engineer replace
0415Y177Power Cable,0.15m,H2X3(3.0),6*20UL1569B,H2X4(4.2)-I Current Engineer replace
0415Y210Power Cable,0.50m&0.62m,Black,80A R/A easy connector,20*18UL2651B,2*80A STR easy connector,Parallel Current Engineer replace
1427Y072BTB Connector module,74pin-36pin*3,UBC 8X Straight,1*Internal mini SAS HD R/A+2*Internal mini SAS HD STR,850mm&400mm&250mm,0.16mm,10mm,1536MB/s,Wire mounting,NULL Current Engineer replace
0415Y120Power Cable,0.15m,BLACK,H2X3(3.0),6*18UL1569 B,H2X3(4.2),tinned copper Current Engineer replace
04153776Power Cable,0.25m,H2X6(3.0),18UL2651(8C)B(Flat),H2X4(4.2) Current Engineer replace
P/NDescription / SpecificationStatus
0231Y192Function Module,2288H V7,BC1M23FAN,8080+ Fan module Current Field replaceable
0231Y191Function Module,2288H V7,BC1M22FAN,8038+ Fan module Current Field replaceable

Operating System Compatibility

Operating SystemVersion / KernelRelease
Citrix Hypervisor 8.24.19.0+1Citrix Hypervisor 8.2 LTSR
Debian 12.56.1.0-18-amd64Debian 12.5 for Intel EM64T
FusionCompute 8.7.05.10.0-136.12.0.86.h1837.eulerosv2r12.x86_64FusionCompute 8.7.0
FusionCompute 8.8.0NAFusionCompute 8.8.0
Oracle Linux 8.105.15.0-206.153.7.1.el8uek.x86_64Oracle Linux Release 8 Update 10 for Intel EM64T
Oracle Linux 9.45.15.0-205.149.5.1.el9uek.x86_64Oracle Linux Release 9 Update 4 for Intel EM64T
RHEL 10.06.12.0-55.9.1.el10_0.x86_64Red Hat Enterprise Linux 10 Server for Intel EM64T
RHEL 10.16.12.0-124.8.1.el10_1.x86_64Red Hat Enterprise Linux 10 Update 1 Server for Intel EM64T
RHEL 10.26.12.0-211.7.3.el10_2.x86_64Red Hat Enterprise Linux 10 Update 2 Server for Intel EM64T
RHEL 8.104.18.0-553.el8_10.x86_64Red Hat Enterprise Linux 8 Update 10 Server for Intel EM64T
RHEL 8.64.18.0-372.9.1.el8.x86_64Red Hat Enterprise Linux 8 Update 6 Server for Intel EM64T
RHEL 8.84.18.0-477.10.1.el8_8.x86_64Red Hat Enterprise Linux 8 Update 8 Server for Intel EM64T
RHEL 8.94.18.0-513.5.1.el8_9.x86_64Red Hat Enterprise Linux 8 Update 9 Server for Intel EM64T
RHEL 9.05.14.0-70.13.1.el9_0.x86_64Red Hat Enterprise Linux 9 Server for Intel EM64T
RHEL 9.15.14.0-162.6.1.el9_1.x86_64Red Hat Enterprise Linux 9 Update 1 Server for Intel EM64T
RHEL 9.25.14.0-284.11.1.el9_2.x86_64Red Hat Enterprise Linux 9 Update 2 Server for Intel EM64T
RHEL 9.45.14.0-427.13.1.el9_4.x86_64Red Hat Enterprise Linux 9 Update 4 Server for Intel EM64T
RHEL 9.55.14.0-503.11.1.el9_5.x86_64Red Hat Enterprise Linux 9 Update 5 Server for Intel EM64T
RHEL 9.65.14.0-570.12.1.el9_6.x86_64Red Hat Enterprise Linux 9 Update 6 Server for Intel EM64T
RHEL 9.75.14.0-611.5.1.el9_7.x86_64Red Hat Enterprise Linux 9 Update 7 Server for Intel EM64T
RHEL 9.85.14.0-687.5.3.el9_8.x86_64Red Hat Enterprise Linux 9 Update 8 Server for Intel EM64T
Rocky Linux 10.06.12.0-55.12.1.el10_0.x86_64Rocky Linux 10 Server for Intel EM64T
Rocky Linux 10.16.12.0-124.8.1.el10_1.x86_64Rocky Linux 10 Update 1 Server for Intel EM64T
Rocky Linux 10.26.12.0-211.16.1.el10_2.0.1.x86_64Rocky Linux 10 Update 2 Server for Intel EM64T
Rocky Linux 8.104.18.0-553.el8_10.x86_64Rocky Linux 8 Update 10 Server for Intel EM64T
Rocky Linux 8.64.18.0-372.9.1.el8.x86_64Rocky Linux 8 Update 6 Server for Intel EM64T
Rocky Linux 8.84.18.0-477.10.1.el8_8.x86_64Rocky Linux 8 Update 8 Server for Intel EM64T
Rocky Linux 8.94.18.0-513.5.1.el8_9.x86_64Rocky Linux 8 Update 9 Server for Intel EM64T
Rocky Linux 9.05.14.0-70.13.1.el9_0.x86_64Rocky Linux 9 Server for Intel EM64T
Rocky Linux 9.15.14.0-162.6.1.el9_1.x86_64Rocky Linux 9 Update 1 Server for Intel EM64T
Rocky Linux 9.25.14.0-284.11.1.el9_2.x86_64Rocky Linux 9 Update 2 Server for Intel EM64T
Rocky Linux 9.45.14.0-427.13.1.el9_4.x86_64Rocky Linux 9 Update 4 Server for Intel EM64T
Rocky Linux 9.55.14.0-503.14.1.el9_5.x86_64Rocky Linux 9 Update 5 Server for Intel EM64T
Rocky Linux 9.65.14.0-570.17.1.el9_6.x86_64Rocky Linux 9 Update 6 Server for Intel EM64T
Rocky Linux 9.75.14.0-611.5.1.el9_7.x86_64Rocky Linux 9 Update 7 Server for Intel EM64T
Rocky Linux 9.85.14.0-687.10.1.el9_8.0.1.x86_64Rocky Linux 9 Update 8 Server for Intel EM64T
SLES 15 SP45.14.21-150400.22-defaultSUSE Linux Enterprise Server 15 Service Pack 4 for AMD64 & Intel64
SLES 15 SP66.4.0-150600.21-defaultSUSE Linux Enterprise Server 15 Service Pack 6 for AMD64 & Intel64
Ubuntu 20.04.5 LTS5.4.0-125-genericUbuntu 20.04.5 LTS Server Edition for Intel EM64T
Ubuntu 20.04.6 LTS5.4.0-144-genericUbuntu 20.04.6 LTS Server Edition for Intel EM64T
Ubuntu 22.04 LTS5.15.0-25-genericUbuntu 22.04 LTS Server Edition for Intel EM64T
Ubuntu 24.04 LTS6.8.0-31-genericUbuntu 24.04 LTS Server Edition for Intel EM64T
Ubuntu 24.04.1 LTS6.8.0-41-genericUbuntu 24.04.1 LTS Server Edition for Intel EM64T
Ubuntu 26.04 LTS7.0.0-14-genericUbuntu 26.04 LTS Server Edition for Intel EM64T
VMware ESXi 7.0 U3build-18644231VMware ESXi 7.0 Update 3 for Intel EM64T
VMware ESXi 8.0build-20513097VMware ESXi 8.0 for Intel EM64T
VMware ESXi 8.0 U2build-22380479VMware ESXi 8.0 Update 2 for Intel EM64T
VMware ESXi 8.0 U3build-24022510VMware ESXi 8.0 Update 3 for Intel EM64T
VMware ESXi 9.1build-25370933VMware ESXi 9.1 for Intel EM64T
Windows Server 2019Build 17763Microsoft Windows Server 2019 x64
Windows Server 2022Build 20348Microsoft Windows Server 2022 x64
Windows Server 2022 Hyper-VBuild 20348Microsoft Windows Server 2022 Hyper-V x64
Windows Server 2025Build 26100Microsoft Windows Server 2025 x64
openEuler 22.03 LTS SP35.10.0-182.0.0.95.oe2203sp3.x86_64openEuler 22.03 LTS SP3 (powered by openEuler)
openEuler 24.03 LTS6.6.0-28.0.0.34.oe2403.x86_64openEuler 24.03 LTS (powered by openEuler)

Configuring, expanding or replacing this server? Send us your part list or BOM for a fast quotation.

Request a Quote

Selecting components for the 2258 V7

These points from the matrix matter when configuring or expanding a unit:

  • Memory: DDR5 RDIMMs from 16GB to 256GB at up to 6400 MT/s. Give us your capacity target and we will confirm the supported DIMM population and channel rules.
  • RAID levels follow the controller. The validated controllers support RAID 1, 5, 6, 10, 50, 60, JBOD. Cacheless entry cards suit boot and mirroring; cached cards with a supercapacitor enable parity RAID for data arrays; JBOD/IT cards provide passthrough to software RAID.
  • Storage mix. Validated options include SAS/SATA drives up to 20 TB and PCIe NVMe SSDs up to 15 TB. Backplane and tray variants are listed separately under Drive Backplanes.
  • Networking from 100GbE to 25GbE. OCP 3.0 and PCIe adapters are validated for the listed speeds; some SKUs include optical modules and others do not, so check the part description.
  • Power: 900–3000W supplies. Platinum and titanium-rated AC units are listed, with redundant pairs for high availability; confirm the rating your GPU and drive population require.

Reference workload profiles

These profiles show how validated components combine; each is configured and quoted to order.

  • Virtualization / private cloud: balanced processors, a large RDIMM footprint, hardware RAID with cache and redundant power.
  • Database / in-memory: high-frequency processors, maximum memory, PCIe NVMe for log and hot data.
  • All-flash node: parity-capable RAID or HBA, a full set of NVMe SSDs, high-wattage titanium PSU.
  • Storage / backup node: cached RAID or JBOD passthrough, a full set of high-capacity drives, high-wattage PSU.
  • General application / infra: mid-bin processors, moderate memory and storage, cost-effective networking.

The 2258 V7 in the FusionServer range

The numbered FusionServer generations make it straightforward to choose between current and supported hardware. The 2258 V7 is a V7 platform: 4th/5th Generation Intel Xeon Scalable, DDR5, PCIe 4.0/5.0.

Earlier supported generations remain useful:

  • V6: 3rd Generation Intel Xeon Scalable, DDR4, PCIe 4.0 — supported, cost-effective for standardised or budget projects.
  • V5: 1st/2nd Generation Intel Xeon Scalable, DDR4, PCIe 3.0 — supported, cost-effective for standardised or budget projects.

We supply new systems with manufacturer warranty and can source validated parts for earlier generations when a budget, software-licensing or support window calls for them. Ask us which generation fits.

2258 V7 — compatibility FAQ

What memory can I install?

Validated DDR5 RDIMMs range from 16GB to 256GB at up to 6400 MT/s. Tell us your capacity target and we will confirm the supported DIMM population.

Which RAID levels are supported?

Validated controllers support RAID 1, 5, 6, 10, 50, 60, JBOD. Choose a cached card with a supercapacitor for parity RAID (5/6/50/60), an entry card for 0/1/10, or an IT/JBOD card for software RAID passthrough.

What drives are validated?

The matrix lists SAS/SATA drives up to 20 TB and NVMe SSDs up to 15 TB. See the Hard Drives and NVMe tabs for the full list, form factors and current status.

What network speeds are supported?

Validated OCP and PCIe adapters cover 100GbE, 10GbE, 200GbE, 25GbE. Note whether a SKU includes optical modules; we can supply matched optics if required.

What power supplies are available?

The list runs from 900W to 3000W in platinum and titanium ratings. Redundant pairs can be configured for high availability; size the PSU to your CPU, GPU and drive load.

Which operating systems are certified?

The OS matrix lists 55 certified builds, including Red Hat Enterprise Linux, Rocky Linux, SUSE Linux Enterprise Server, Ubuntu, VMware ESXi, Windows Server, each with its exact kernel or build string. Additional builds can often be confirmed on request.

What do the lifecycle statuses mean?

Current/GA parts are in production; PILOT and DEVELOP parts are under limited rollout or qualification; EOM parts are out of marketing but supported as spares. Prefer Current parts for new builds.

Can you supply the server or just parts?

Both. We configure complete systems and supply every validated component listed here with warranty. Send a part list or BOM for a fast quotation.