Call: +86 18001060290    E-mail: info@sell-server.com

FusionServer G5500 V7 Compatibility

FusionServer G5500 V7 Compatibility

The FusionServer G5500 V7 is an accelerator-optimised server built around multiple GPUs with high-power cooling and high-speed interconnect. It is a GPU/AI compute platform, designed for AI training and inference, scientific computing, GPU virtualization and graphics workloads. The platform runs on 4th/5th Generation Intel Xeon Scalable with DDR5 memory and PCIe 4.0/5.0 expansion.

Below is the verified compatibility matrix for this model: 527 validated line items across 11 component categories and 56 certified operating-system builds, taken from xFusion’s official compatibility data and presented in English. Every part number listed is published by xFusion for this chassis; nothing is guessed or cross-filled from other models.

Form factorAn accelerator-optimised server built around multiple GPUs with high-power cooling and high-speed interconnect
Processor options45 validated SKUs
Top core countUp to 64 cores / socket
Memory modulesDDR5 16–128GB
Memory speedUp to 6400 MT/s
Largest drive20 TB
NVMe capacityUp to 8 TB
Network speeds10GbE/25GbE/200GbE
Power supplies2000–3000W
Validated527 parts · 56 OS

Compatibility matrix

Browse validated parts by category using the tabs below. Each tab shows its item count; search inside a tab by part number or keyword, and expand the full list. Parts marked Current are actively orderable; life-cycle parts are still supported and often available as spares. The OS table lists the exact certified kernel or build.

P/NDescription / SpecificationStatus
4102Y016X86 series-FCLGA4677-2000MHz-1.6V/1.83V-64bit-350000mW-Sapphire Rapids XCC CPU-Intel Xeon Platinum 8480+-56Core Current
4102Y020X86 series-FCLGA4677-2000MHz-1.6V/1.83V-64bit-300000mW-Sapphire Rapids XCC CPU-Intel Xeon Platinum 8452Y-36Core Current
4102Y021X86 series-FCLGA4677-2100MHz-1.6V/1.83V-64bit-270000mW-Sapphire Rapids XCC CPU-Intel Xeon Gold 6430-32Core Current
4102Y025X86 series-FCLGA4677-1900MHz-1.6V/1.83V-64bit-350000mW-Sapphire Rapids XCC CPU-Intel Xeon Platinum 8490H-60Core Current
4102Y048X86 series-FCLGA4677-2000MHz-1.6V/1.83V-64bit-185000mW-Sapphire Rapids MCC CPU-Intel Xeon Gold 5418Y-24Core Current
4102Y052X86 series-FCLGA4677-2400MHz-1.6V/1.83V-64bit-250000mW-Sapphire Rapids MCC CPU-Intel Xeon Gold 6448H-32Core Current
4102Y056X86 series-FCLGA4677-2000MHz-1.6V/1.83V-64bit-205000mW-Sapphire Rapids MCC CPU-Intel Xeon Gold 6438N-32Core Current
4102Y064X86 series-FCLGA4677-2000MHz-1.6V/1.83V-64bit-150000mW-Sapphire Rapids MCC CPU-Intel Xeon Gold 5416S-16Core Current
4102Y072X86 series-FCLGA4677-2000MHz-1.6V/1.83V-64bit-350000mW-Sapphire Rapids XCC CPU-Intel Xeon Platinum 8480C-56Core Current
4102Y075X86 series-FCLGA4677-3300MHz-1.6V/1.83V-64bit-350000mW-Sapphire Rapids MCC CPU-Intel Xeon Gold 6460C-32Core Current
4102Y098X86 series-FCLGA4677-2600MHz-1.6V/1.83V-64bit-350000mW-Sapphire Rapids XCC CPU-Intel Xeon Platinum 8463B-48Core Current
4102Y103X86 series-FCLGA4677-2600MHz-1.6V/1.83V-64bit-350000mW-Sapphire Rapids XCC CPU-Intel Xeon Platinum 8457C-48Core Current
4102Y109X86 series-FCLGA4677-2600MHz-1.6V/1.83V-64bit-385000mW-Emerald Rapids XCC CPU-Intel Xeon Platinum 8566C-52Core Current
4102Y110X86 series-FCLGA4677-2700MHz-1.6V/1.83V-64bit-350000mW-Emerald Rapids XCC CPU-Intel Xeon Platinum 8558P-48Core Current
4102Y112X86 series-FCLGA4677-2000MHz-1.6V/1.83V-64bit-330000mW-Emerald Rapids XCC CPU-Intel Xeon Platinum 8592V-64Core Current
4102Y113X86 series-FCLGA4677-1900MHz-1.6V/1.83V-64bit-350000mW-Emerald Rapids XCC CPU-Intel Xeon Platinum 8592+-64Core Current
4102Y114X86 series-FCLGA4677-2000MHz-1.6V/1.83V-64bit-350000mW-Emerald Rapids XCC CPU-Intel Xeon Platinum 8580-60Core Current
4102Y117X86 series-FCLGA4677-2800MHz-1.6V/1.83V-64bit-300000mW-Emerald Rapids MCC CPU-Intel Xeon Platinum 8562Y+-32Core Current
4102Y118X86 series-FCLGA4677-2500MHz-1.6V/1.83V-64bit-250000mW-Emerald Rapids MCC CPU-Intel Xeon Gold 6548Y+-32Core Current
4102Y121X86 series-FCLGA4677-2800MHz-1.6V/1.83V-64bit-195000mW-Emerald Rapids MCC CPU-Intel Xeon Gold 6526Y-16Core Current
4102Y124X86 series-FCLGA4677-2100MHz-1.6V/1.83V-64bit-330000mW-Emerald Rapids XCC CPU-Intel Xeon Platinum 8558-48Core Current
4102Y126X86 series-FCLGA4677-2100MHz-1.6V/1.83V-64bit-270000mW-Emerald Rapids XCC CPU-Intel Xeon Gold 6530-32Core Current
4102Y128X86 series-FCLGA4677-2200MHz-1.6V/1.83V-64bit-185000mW-Emerald Rapids MCC CPU-Intel Xeon Silver 4516Y+-24Core Current
4102Y129X86 series-FCLGA4677-2000MHz-1.6V/1.83V-64bit-150000mW-Emerald Rapids MCC CPU-Intel Xeon Silver 4514Y-16Core Current
4102Y135X86 series-FCLGA4677-2800MHz-1.6V/1.83V-64bit-250000mW-Emerald Rapids MCC CPU-Intel Xeon Gold 6548N-32Core Current
4102Y138X86 series-FCLGA4677-2600MHz-1.6V/1.83V-64bit-385000mW-Emerald Rapids XCC CPU-Intel Xeon Platinum 8582C-60Core Current
4102Y139X86 series-FCLGA4677-2400MHz-1.6V/1.83V-64bit-150000mW-Sapphire Rapids EE LCC 4510-12Core Current
4102Y141-A01X86 series-FCLGA4677-2600MHz-1.6V/1.83V-64bit-385000mW-Emerald Rapids XCC CPU-Intel Xeon Platinum 8563C-52Core Current
4102Y017X86 series-FCLGA4677-2000MHz-1.6V/1.83V-64bit-350000mW-Sapphire Rapids XCC CPU-Intel Xeon Platinum 8470-52Core EOM
4102Y018X86 series-FCLGA4677-2100MHz-1.6V/1.83V-64bit-350000mW-Sapphire Rapids XCC CPU-Intel Xeon Platinum 8468-48Core EOM
4102Y019X86 series-FCLGA4677-2000MHz-1.6V/1.83V-64bit-300000mW-Sapphire Rapids XCC CPU-Intel Xeon Platinum 8460Y+-40Core EOM
4102Y022X86 series-FCLGA4677-2400MHz-1.6V/1.83V-64bit-330000mW-Sapphire Rapids XCC CPU-Intel Xeon Platinum 8468V-48Core EOM
4102Y023X86 series-FCLGA4677-2700MHz-1.6V/1.83V-64bit-350000mW-Sapphire Rapids XCC CPU-Intel Xeon Platinum 8458P-44Core EOM
4102Y035X86 series-FCLGA4677-2200MHz-1.6V/1.83V-64bit-270000mW-Sapphire Rapids XCC CPU-Intel Xeon Gold 6454S-32Core EOM
4102Y039X86 series-FCLGA4677-2800MHz-1.6V/1.83V-64bit-300000mW-Sapphire Rapids MCC CPU-Intel Xeon Platinum 8462Y+-32Core EOM
4102Y040X86 series-FCLGA4677-2100MHz-1.6V/1.83V-64bit-225000mW-Sapphire Rapids MCC CPU-Intel Xeon Gold 6448Y-32Core EOM
4102Y041X86 series-FCLGA4677-2600MHz-1.6V/1.83V-64bit-225000mW-Sapphire Rapids MCC CPU-Intel Xeon Gold 6442Y-24Core EOM
4102Y042X86 series-FCLGA4677-3600MHz-1.6V/1.83V-64bit-270000mW-Sapphire Rapids MCC CPU-Intel Xeon Gold 6444Y-16Core EOM
4102Y043X86 series-FCLGA4677-2500MHz-1.6V/1.83V-64bit-185000mW-Sapphire Rapids MCC CPU-Intel Xeon Gold 6426Y-16Core EOM
4102Y044X86 series-FCLGA4677-3700MHz-1.6V/1.83V-64bit-195000mW-Sapphire Rapids MCC CPU-Intel Xeon Gold 6434-8Core EOM
4102Y045X86 series-FCLGA4677-2900MHz-1.6V/1.83V-64bit-150000mW-Sapphire Rapids MCC CPU-Intel Xeon Gold 5415+-8Core EOM
4102Y046X86 series-FCLGA4677-2000MHz-1.6V/1.83V-64bit-205000mW-Sapphire Rapids MCC CPU-Intel Xeon Gold 6438Y+-32Core EOM
4102Y047X86 series-FCLGA4677-2000MHz-1.6V/1.83V-64bit-205000mW-Sapphire Rapids MCC CPU-Intel Xeon Gold 5420+-28Core EOM
4102Y049X86 series-FCLGA4677-2000MHz-1.6V/1.83V-64bit-165000mW-Sapphire Rapids MCC CPU-Intel Xeon Silver 4416+-20Core EOM
4102Y050X86 series-FCLGA4677-2000MHz-1.6V/1.83V-64bit-150000mW-Sapphire Rapids MCC CPU-Intel Xeon Silver 4410Y-12Core EOM
4102Y051X86 series-FCLGA4677-2200MHz-1.6V/1.83V-64bit-205000mW-Sapphire Rapids MCC CPU-Intel Xeon Gold 6438M-32Core EOM
90010339Liquid Manufactory Auxiliaries,Thermal Grease,X-23-7868-2D,Thermal Conductivity 3.6W/mK / 6.0W/mK,2g,Gap filling thermal conductive for customer use,1ml Current
4102Y119X86 series,FCLGA4677,2900MHz,1.6V/1.83V,64bit,250000mW,Emerald Rapids MCC CPU-Intel Xeon Gold 6542Y-24Core Current Field replaceable
4102Y061X86 series,FCLGA4677,3100MHz,1.6V/1.83V,64bit,350000mW,Sapphire Rapids MCC CPU-Intel Xeon Gold 6458Q-32Core Current Field replaceable
4102Y033X86 series,FCLGA4677,2100MHz,1.6V/1.83V,64bit,350000mW,Sapphire Rapids XCC CPU-Intel Xeon Platinum 8470Q-52Core Current Field replaceable
P/NDescription / SpecificationStatus
0251Y062memory module-2288H V7-generic memory-DDR5-RDIMM-64GB-288pin-0.42ns-4800000KHz-1.1V-ECC-2Rank(4G*4bit)-overseas dedicated Current
0251Y064memory module-2288H V7-generic memory-DDR5-RDIMM-16GB-288pin-0.42ns-4800000KHz-1.1V-ECC-1Rank(2G*8bit)-overseas dedicated Current
0251Y112memory module-2288H V7-generic memory-DDR5-RDIMM-64GB-288pin-0.42ns-4800000KHz-1.1V-ECC-2Rank(4G*4bit) Current
0251Y143memory module-2258 V7-generic memory-DDR5-RDIMM-32GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(2G*8bit)-3-way OEM code_overseas dedicated Current
0251Y144memory module-2258 V7-generic memory-DDR5-RDIMM-64GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(4G*4bit)-3-way OEM code_overseas dedicated Current
0251Y150memory module-2288H V7-generic memory-DDR5-RDIMM-16GB-288pin-0.357ns-5600000KHz-1.1V-ECC-1Rank(2G*8bit)-overseas dedicated Current
0251Y177memory module-2258 V7-generic memory-DDR5-RDIMM-64GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(4G*4bit)-XH-overseas dedicated Current
0251Y193memory module-2288H V7-generic memory-DDR5-RDIMM-32GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(2G*8bit)-Samsung Current
0251Y194memory module-2258 V7-generic memory-DDR5-RDIMM-64GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(4G*4bit)-Samsung Current
0251Y197memory module-2288H V7-generic memory-DDR5-RDIMM-32GB-288pin-0.42ns-4800000KHz-1.1V-ECC-2Rank(2G*8bit)-overseas dedicated-spec code Current
0251Y198memory module-2288H V7-generic memory-DDR5-RDIMM-16GB-288pin-0.42ns-4800000KHz-1.1V-ECC-1Rank(2G*8bit)-overseas dedicated-spec code Current
0251Y202memory module-2288H V7-generic memory-DDR5-RDIMM-32GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(2G*8bit)-overseas dedicated-spec code Current
0251Y203memory module-2288H V7-generic memory-DDR5-RDIMM-64GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(4G*4bit)-overseas dedicated-spec code Current
0251Y206memory module-2288H V7-generic memory-DDR5-RDIMM-16GB-288pin-0.357ns-5600000KHz-1.1V-ECC-1Rank(2G*8bit)-overseas dedicated-spec code Current
0251Y220memory module-Fusion Sever-generic memory-DDR5-RDIMM-64GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(4G*4bit) Current
0251Y287memory module-2288H V7-M564R32-generic memory-DDR5-RDIMM-32GB-288pin-0.312ns-6400000KHz-1.1V-ECC-2Rank(2G*8bit)-overseas dedicated Current
0251Y288memory module-2288H V7-M564R64-generic memory-DDR5-RDIMM-64GB-288pin-0.312ns-6400000KHz-1.1V-ECC-2Rank(4G*4bit)-overseas dedicated Current
0251Y289memory module-2288H V7-M564R96-generic memory-DDR5-RDIMM-96GB-288pin-0.312ns-6400000KHz-1.1V-ECC-2Rank(6G*4bit)-3-way OEM code_overseas dedicated Current
0251Y290memory module-2288H V7-M564R128-generic memory-DDR5-RDIMM-128GB-288pin-0.312ns-6400000KHz-1.1V-ECC-2Rank(8G*4bit)-3-way OEM code_overseas dedicated Current
0251Y291memory module-2288H V7-M556R64-generic memory-DDR5-RDIMM-64GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(4G*4bit)-for use in China only Current
0251Y297memory module-2288H V7-M564R32-generic memory-DDR5-RDIMM-32GB-288pin-0.312ns-6400000KHz-1.1V-ECC-2Rank(2G*8bit)-Samsung 1bnm-Turin platform prohibited Current
0251Y314memory module-M556R32-DDR5 RDIMM-32GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(2G*8bit) Current
0251Y315memory module-2288H V7-M564R32-generic memory-DDR5-RDIMM-32GB-288pin-0.312ns-6400000KHz-1.1V-ECC-2Rank(2G*8bit)-Samsung 1bnm-Turin platform prohibited Current
0251Y316memory module-2258 V7-M556R64-generic memory-DDR5-RDIMM-64GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(4G*4bit)-CXMT G4-down-binned die Current
0251Y317memory module-2288H V7-generic memory-DDR5-RDIMM-64GB-288pin-0.312ns-6400000KHz-1.1V-ECC-2Rank(4G*4bit) Current
0251Y325memory module-2288H V7-M564R32-generic memory-DDR5-RDIMM-32GB-288pin-0.312ns-6400000KHz-1.1V-ECC-2Rank(2G*8bit)-Samsung 1bnm-Turin platform prohibited Current
0251Y326memory module-DDR5 RDIMM-64GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(4G*4bit) Current
0251Y344memory module-2258 V7-M564R64-generic memory-DDR5-RDIMM-64GB-288pin-0.312ns-6400000KHz-1.1V-ECC-2Rank(4G*4bit)-Samsung 1bnm-Turin platform prohibited Current
06200484generic memory-DDR5-RDIMM-64GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(4G*4bit)-HYNIX 1anm Current
0620Y006-006generic memory-DDR5-RDIMM-64GB-288pin-0.42ns-4800000KHz-1.1V-ECC-2Rank(4G*4bit)-3-way OEM code Current
0620Y006-023generic memory-DDR5-RDIMM-64GB-288pin-0.42ns-4800000KHz-1.1V-ECC-2Rank(4G*4bit)-Landun Technology customer-supplied material Current
0620Y019generic memory-DDR5-RDIMM-48GB-288pin-0.416ns-4800000KHz-1.1V-ECC-2Rank(3G*8bit) Current
0620Y026generic memory-DDR5-RDIMM-96GB-288pin-0.416ns-4800000KHz-1.1V-ECC-2Rank(6G*4bit) Current
0620Y027generic memory-DDR5-RDIMM-16GB-288pin-0.357ns-5600000KHz-1.1V-ECC-1Rank(2G*8bit) Current
0620Y027-003generic memory-DDR5-RDIMM-16GB-288pin-0.357ns-5600000KHz-1.1V-ECC-1Rank(2G*8bit)-3-way OEM code_overseas dedicated Current
0620Y029generic memory-DDR5-RDIMM-32GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(2G*8bit) Current
0620Y029-001generic memory-DDR5-RDIMM-32GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(2G*8bit)-SK Hynix 1anm-designated-model dedicated Current
0620Y029-006generic memory-DDR5-RDIMM-32GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(2G*8bit)-CXMT G4 Current
0620Y029-020generic memory-DDR5-RDIMM-32GB-288pin-0.312ns-6400000KHz-1.1V-ECC-2Rank(2G*8bit)-Samsung 1bnm-Turin platform prohibited Current
0620Y030generic memory-DDR5-RDIMM-48GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(3G*8bit) Current
0620Y031generic memory-DDR5-RDIMM-64GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(4G*4bit) Current
0620Y031-004generic memory-DDR5-RDIMM-64GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(4G*4bit)-SK Hynix 1anm Current
0620Y031-005generic memory-DDR5-RDIMM-64GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(4G*4bit)-3-way OEM code_overseas dedicated Current
0620Y031-008generic memory-DDR5-RDIMM-64GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(4G*4bit) Current
0620Y031-012generic memory-DDR5-RDIMM-64GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(4G*4bit)-CXMT G4 Current
0620Y031-016generic memory-DDR5-RDIMM-64GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(4G*4bit)-SK Hynix 1anm -Landun Technology customer-supplied material Current
0620Y031-024generic memory-DDR5-RDIMM-64GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(4G*4bit)-XH consumable virtual code-for use in China Current
0620Y031-025generic memory-DDR5-RDIMM-64GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(4G*4bit)-CXMT G4-down-binned die Current
0620Y031-028generic memory-DDR5-RDIMM-64GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(4G*4bit)-Tigo/kingbank Current
0620Y031-029generic memory-DDR5-RDIMM-64GB-288pin-0.312ns-6400000KHz-1.1V-ECC-2Rank(4G*4bit)-Samsung 1bnm-Turin platform prohibited Current
0620Y032generic memory-DDR5-RDIMM-96GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(6G*4bit) Current
0620Y032-001generic memory-DDR5-RDIMM-96GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(6G*4bit)-SAMSUNG 1anm Current
0620Y032-005generic memory-DDR5-RDIMM-96GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(6G*4bit)-SK Hynix 1anm-designated-model dedicated Current
0620Y035generic memory-DDR5-RDIMM-128GB-288pin-0.312ns-6400000KHz-1.1V-ECC-2Rank(8G*4bit) Current
0620Y040generic memory-DDR5-RDIMM-32GB-288pin-0.312ns-6400000KHz-1.1V-ECC-2Rank(2G*8bit) Current
0620Y040-008generic memory-DDR5-RDIMM-32GB-288pin-0.312ns-6400000KHz-1.1V-ECC-2Rank(2G*8bit)-CXMT Current
0620Y042generic memory-DDR5-RDIMM-64GB-288pin-0.312ns-6400000KHz-1.1V-ECC-2Rank(4G*4bit) Current
0620Y042-011generic memory-DDR5-RDIMM-64GB-288pin-0.312ns-6400000KHz-1.1V-ECC-2Rank(4G*4bit)-CXMT Current
0620Y042-016generic memory-DDR5-RDIMM-64GB-288pin-0.312ns-6400000KHz-1.1V-ECC-2Rank(4G*4bit)-Hynix_Zhongying Intelligent customer-supplied material Current
0620Y043generic memory-DDR5-RDIMM-96GB-288pin-0.312ns-6400000KHz-1.1V-ECC-2Rank(6G*4bit) Current
0620Y061generic memory-DDR5-RDIMM-128GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(8G*4bit)-SDP Current
0620Y068generic memory-DDR5-RDIMM-16GB-288pin-0.42ns-4800000KHz-1.1V-ECC-1Rank(2G*8bit)-spec code Current
0620Y069generic memory-DDR5-RDIMM-32GB-288pin-0.42ns-4800000KHz-1.1V-ECC-2Rank(2G*8bit)-spec code Current
0620Y070generic memory-DDR5-RDIMM-64GB-288pin-0.42ns-4800000KHz-1.1V-ECC-2Rank(4G*4bit)-spec code Current
0620Y071generic memory-DDR5-RDIMM-32GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(2G*8bit)-spec code Current
0620Y072generic memory-DDR5-RDIMM-64GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(4G*4bit)-spec code Current
0251Y063memory module-2288H V7-generic memory-DDR5-RDIMM-32GB-288pin-0.42ns-4800000KHz-1.1V-ECC-2Rank(2G*8bit)-overseas dedicated EOM
0251Y125memory module-2288H V7-generic memory-DDR5-RDIMM-64GB-288pin-0.42ns-4800000KHz-1.1V-ECC-2Rank(4G*4bit) EOS
0251Y174memory module-2288H V7-generic memory-DDR5-RDIMM-64GB-288pin-0.42ns-4800000KHz-1.1V-ECC-2Rank(4G*4bit)-XH EOM
0620Y003generic memory-DDR5-RDIMM-16GB-288pin-0.42ns-4800000KHz-1.1V-ECC-1Rank(2G*8bit) EOM
0620Y003-001generic memory-DDR5-RDIMM-16GB-288pin-0.42ns-4800000KHz-1.1V-ECC-1Rank(2G*8bit)-designated-model dedicated-Samsung 1ynm EOM
0620Y003-002generic memory-DDR5-RDIMM-16GB-288pin-0.42ns-4800000KHz-1.1V-ECC-1Rank(2G*8bit)-designated-model dedicated-Hynix 1anm EOM
0620Y005generic memory-DDR5-RDIMM-32GB-288pin-0.42ns-4800000KHz-1.1V-ECC-2Rank(2G*8bit) EOM
0620Y005-001generic memory-DDR5-RDIMM-32GB-288pin-0.42ns-4800000KHz-1.1V-ECC-2Rank(2G*8bit)-designated-model dedicated-Samsung 1ynm EOM
0620Y005-002generic memory-DDR5-RDIMM-32GB-288pin-0.42ns-4800000KHz-1.1V-ECC-2Rank(2G*8bit)-designated-model dedicated-Hynix 1anm EOM
0620Y006generic memory-DDR5-RDIMM-64GB-288pin-0.42ns-4800000KHz-1.1V-ECC-2Rank(4G*4bit) EOM
0620Y006-001generic memory-DDR5-RDIMM-64GB-288pin-0.42ns-4800000KHz-1.1V-ECC-2Rank(4G*4bit)-designated-model dedicated-Samsung 1ynm EOM
0620Y006-002generic memory-DDR5-RDIMM-64GB-288pin-0.42ns-4800000KHz-1.1V-ECC-2Rank(4G*4bit)-designated-model dedicated-Hynix 1anm EOM
0620Y009generic memory-DDR5-RDIMM-128GB-288pin-0.42ns-4800000KHz-1.1V-ECC-4Rank(4G*4bit)-3DS EOM
0620Y027-001generic memory-DDR5-RDIMM-16GB-288pin-0.357ns-5600000KHz-1.1V-ECC-1Rank(2G*8bit)-designated-model dedicated-Samsung 1anm EOM
0620Y029-002generic memory-DDR5-RDIMM-32GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(2G*8bit)-designated-model dedicated-Samsung 1anm EOM
0620Y031-001generic memory-DDR5-RDIMM-64GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(4G*4bit)-Samsung 1anm EOM
0620Y031-003generic memory-DDR5-RDIMM-64GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(4G*4bit)-SAMSUNG 1anm EOM
P/NDescription / SpecificationStatus
02540041generic drive module-Servers-generic drive-4000GB-SATA 6.0Gb/s-7.2K rpm-3.5inch-128MB or above-hot-swap-internal-3.5 inch bracket Current
02540043generic drive module-Servers-generic drive-8000GB-SATA 6.0Gb/s-7.2K rpm-3.5inch-128MB or above-hot-swap-internal-3.5 inch bracket Current
0254Y057generic drive module-Servers-generic drive-600GB-SAS 12Gb/s-10000rpm-2.5inch-128MB and above-hot-swap-internal-2.5 inch bracket-V7 server dedicated Current
0254Y058generic drive module-Servers-generic drive-600GB-SAS 12Gb/s-10000rpm-2.5inch-128MB and above-hot-swap-internal-3.5 inch bracket-V7 server dedicated Current
0254Y059generic drive module-Servers-generic drive-1200GB-SAS 12Gb/s-10000rpm-2.5inch-128MB and above-hot-swap-internal-2.5 inch bracket-V7 server dedicated Current
0254Y060generic drive module-Servers-generic drive-1200GB-SAS 12Gb/s-10000rpm-2.5inch-128MB and above-hot-swap-internal-3.5 inch bracket-V7 server dedicated Current
0254Y061generic drive module-Servers-generic drive-1800GB-SAS 12Gb/s-10000rpm-2.5inch-128MB-hot-swap-internal-2.5 inch bracket-V7 server dedicated Current
0254Y062generic drive module-Servers-generic drive-1800GB-SAS 12Gb/s-10000rpm-2.5inch-128MB-hot-swap-internal-3.5 inch bracket-V7 server dedicated Current
0254Y063generic drive module-Servers-generic drive-2400GB-SAS 12Gb/s-10000rpm-2.5inch-256MB-hot-swap-internal-2.5 inch bracket-V7 server dedicated Current
0254Y064generic drive module-Servers-generic drive-2400GB-SAS 12Gb/s-10000rpm-2.5inch-256MB-hot-swap-internal-3.5 inch bracket-V7 server dedicated Current
0254Y065generic drive module-Servers-generic drive-4000GB-SATA 6.0Gb/s-7.2K rpm-3.5inch-128MB or above-hot-swap-internal-3.5 inch bracket-V7 server dedicated Current
0254Y066generic drive module-Servers-generic drive-6000GB-SATA 6.0Gb/s-7.2K rpm-3.5inch-128MB or above-hot-swap-internal-3.5 inch bracket-V7 server dedicated Current
0254Y067generic drive module-Servers-generic drive-8000GB-SATA 6.0Gb/s-7.2K rpm-3.5inch-128MB or above-hot-swap-internal-3.5 inch bracket-V7 server dedicated Current
0254Y068generic drive module-Servers-generic drive-10TB-SATA 6.0Gb/s-7.2K rpm-3.5inch-256MB-hot-swap-internal-3.5 inch bracket-V7 server dedicated Current
0254Y069generic drive module-Servers-generic drive-12TB-SATA 6.0Gb/s-7.2K rpm-3.5inch-256MB-hot-swap-internal-3.5 inch bracket-V7 server dedicated Current
0254Y071generic drive module-Servers-generic drive-16TB-SATA 6.0Gb/s-7.2K rpm-3.5 inch-hot-swap-internal-3.5 inch bracket-V7 server dedicated Current
0254Y072generic drive module-Servers-generic drive-18TB-SATA 6.0Gb/s-7.2K rpm-3.5 inch-hot-swap-internal-3.5 inch bracket-V7 server dedicated Current
0254Y096generic drive module-Servers-generic drive-20TB-SATA 6.0Gb/s-7.2K rpm-3.5 inch-hot-swap-internal-3.5 inch bracket-V7 server dedicated Current
0254Y356generic drive module-Servers-generic drive-2400GB-SAS 12Gb/s-10000rpm-2.5inch-256MB and above-hot-swap-internal-2.5 inch bracket-V7 server dedicated-Seagate dedicated Current
0254Y357generic drive module-Servers-generic drive-2400GB-SAS 12Gb/s-10000rpm-2.5inch-256MB-hot-swap-internal-3.5 inch bracket-V7 server dedicated-Seagate dedicated Current
0254Y358generic drive module-Servers-generic drive-2400GB-SAS 12Gb/s-10000rpm-2.5inch-128MB-hot-swap-internal-2.5 inch bracket-V7 server dedicated-Toshiba dedicated Current
0254Y359generic drive module-Servers-generic drive-2400GB-SAS 12Gb/s-10000rpm-2.5inch-256MB-hot-swap-internal-3.5 inch bracket-V7 server dedicated-Toshiba dedicated Current
0254Y369generic drive module-Servers-generic drive-600GB-SAS 12Gb/s-10000rpm-2.5inch-128MB and above-hot-swap-internal-2.5 inch bracket-V7 server dedicated-Seagate dedicated Current
0254Y370generic drive module-Servers-generic drive-600GB-SAS 12Gb/s-10000rpm-2.5inch-128MB and above-hot-swap-internal-2.5 inch bracket-V7 server dedicated-Toshiba dedicated Current
0254Y442generic drive module-Servers-generic drive-20TB-SATA 6.0Gb/s-7.2K rpm-3.5 inch-hot-swap-internal-3.5 inch bracket-V7 dedicated-Toshiba-customer designated Current
0254Y470generic drive module-Servers-generic drive-8000GB-SATA 6.0Gb/s-7.2K rpm-3.5inch-128MB or above-hot-swap-internal-3.5 inch bracket-SEAGATE-V7 dedicated Current
0254Y496generic drive module-Servers-generic drive-8000GB-SATA 6.0Gb/s-7.2K rpm-3.5inch-128MB or above-hot-swap-internal-3.5 inch bracket-WD-V7 dedicated Current
0254Y512generic drive module-Servers-generic drive-4000GB-SATA 6.0Gb/s-7.2K rpm-3.5inch-128MB or above-hot-swap-internal-3.5 inch bracket-V7 dedicated-spec code Current
0254Y514generic drive module-Servers-generic drive-8000GB-SATA 6.0Gb/s-7.2K rpm-3.5inch-128MB or above-hot-swap-internal-3.5 inch bracket-V7 dedicated-spec code Current
0254Y516generic drive module-Servers-generic drive-12TB-SATA 6.0Gb/s-7.2K rpm-3.5inch-256MB-hot-swap-internal-3.5 inch bracket-V7 dedicated-spec code Current
0254Y518generic drive module-Servers-generic drive-16TB-SATA 6.0Gb/s-7.2K rpm-3.5inch-hot-swap-internal-3.5 inch bracket-V7 dedicated-spec code Current
0254Y520generic drive module-Servers-generic drive-18TB-SATA 6.0Gb/s-7.2K rpm-3.5inch-hot-swap-internal-3.5 inch bracket-V7 dedicated-spec code Current
0254Y522generic drive module-Servers-generic drive-20TB-SATA 6.0Gb/s-7.2K rpm-3.5inch-hot-swap-internal-3.5 inch bracket-V7 dedicated-spec code Current
0254Y533generic drive module-Servers-generic drive-600GB-SAS 12Gb/s-10000rpm-2.5inch-128MB and above-hot-swap-internal-2.5 inch bracket-V7 dedicated-spec code Current
0254Y539generic drive module-Servers-generic drive-2400GB-SAS 12Gb/s-10000rpm-2.5inch-256MB-hot-swap-internal-2.5 inch bracket-V7 dedicated-spec code Current
0254Y540generic drive module-Servers-generic drive-2400GB-SAS 12Gb/s-10000rpm-2.5inch-256MB-hot-swap-internal-3.5 inch bracket-V7 dedicated-spec code Current
0254Y691generic drive module-Servers-generic drive-20TB-SATA 6.0Gb/s-7.2K rpm-3.5 inch-hot-swap-internal-3.5 inch bracket-designated-model dedicated-Summit V7 server dedicated Current
0254Y693generic drive module-Servers-generic drive-16000GB-SATA 6.0Gb/s-7.2K rpm-3.5inch-256MB-hot-swap-internal-3.5 inch bracket-designated-model dedicated-Summit V7 server dedicated Current
0254Y696generic drive module-Servers-generic drive-4000GB-SATA 6.0Gb/s-7.2K rpm-3.5inch-128MB or above-hot-swap-internal-3.5 inch bracket-Seagate V7 server dedicated Current
0254Y697generic drive module-Servers-generic drive-4000GB-SATA 6.0Gb/s-7.2K rpm-3.5inch-128MB or above-hot-swap-internal-3.5 inch bracket-WD V7 server dedicated Current
0254Y700generic drive module-Servers-generic drive-600GB-SAS 12Gb/s-10000rpm-2.5inch-128MB and above-hot-swap-internal-3.5 inch bracket-V7 server dedicated-Seagate dedicated Current
0254Y701generic drive module-Servers-generic drive-600GB-SAS 12Gb/s-10000rpm-2.5inch-128MB and above-hot-swap-internal-3.5 inch bracket-V7 dedicated-spec code Current
0254Y702generic drive module-Servers-generic drive-600GB-SAS 12Gb/s-10000rpm-2.5inch-128MB and above-hot-swap-internal-3.5 inch bracket-V7 server dedicated-Toshiba dedicated Current
0254Y704generic drive module-Servers-generic drive-1200GB-SAS 12Gb/s-10000rpm-2.5inch-128MB and above-hot-swap-internal-2.5 inch bracket-V7 dedicated-spec code Current
0254Y705generic drive module-Servers-generic drive-1200GB-SAS 12Gb/s-10000rpm-2.5inch-128MB and above-hot-swap-internal-3.5 inch bracket-V7 dedicated-spec code Current
0254Y706generic drive module-Servers-generic drive-1800GB-SAS 12Gb/s-10000rpm-2.5inch-128MB and above-hot-swap-internal-2.5 inch bracket-V7 dedicated-spec code Current
0254Y707generic drive module-Servers-generic drive-1800GB-SAS 12Gb/s-10000rpm-2.5inch-128MB and above-hot-swap-internal-3.5 inch bracket-V7 dedicated-spec code Current
0254Y708generic drive module-Servers-generic drive-1200GB-SAS 12Gb/s-10000rpm-2.5inch-128MB and above-hot-swap-internal-3.5 inch bracket-V7 server dedicated-Seagate dedicated Current
0254Y709generic drive module-Servers-generic drive-1200GB-SAS 12Gb/s-10000rpm-2.5inch-128MB and above-hot-swap-internal-3.5 inch bracket-V7 server dedicated-Toshiba dedicated Current
0254Y710generic drive module-Servers-generic drive-1200GB-SAS 12Gb/s-10000rpm-2.5inch-128MB and above-hot-swap-internal-2.5 inch bracket-V7 server dedicated-Seagate dedicated Current
0254Y711generic drive module-Servers-generic drive-1200GB-SAS 12Gb/s-10000rpm-2.5inch-128MB and above-hot-swap-internal-2.5 inch bracket-V7 server dedicated-Toshiba dedicated Current
0254Y712generic drive module-Servers-generic drive-1800GB-SAS 12Gb/s-10000rpm-2.5inch-128MB and above-hot-swap-internal-3.5 inch bracket-V7 server dedicated-Seagate dedicated Current
0254Y713generic drive module-Servers-generic drive-1800GB-SAS 12Gb/s-10000rpm-2.5inch-128MB and above-hot-swap-internal-3.5 inch bracket-V7 server dedicated-Toshiba dedicated Current
0254Y714generic drive module-Servers-generic drive-1800GB-SAS 12Gb/s-10000rpm-2.5inch-128MB and above-hot-swap-internal-2.5 inch bracket-V7 server dedicated-Seagate dedicated Current
0254Y715generic drive module-Servers-generic drive-1800GB-SAS 12Gb/s-10000rpm-2.5inch-128MB and above-hot-swap-internal-2.5 inch bracket-V7 server dedicated-Toshiba dedicated Current
0254Y852generic drive module-Servers-generic drive-8000GB-SATA 6.0Gb/s-7.2K rpm-3.5inch-256MB-hot-swap-internal-3.5 inch bracket-WDC Vela-A1-V7 dedicated Current
0254Y948generic drive module-Servers-generic drive-12000GB-NL SAS 12Gb/s-7200rpm-3.5inch-256MB-hot-swap-internal-3.5 inch bracket-Paris-CP V7 server dedicated Current
0254Y949generic drive module-Servers-generic drive-16000GB-NL SAS 12.0Gb/s-7200rpm-3.5inch-256MB-hot-swap-internal-3.5 inch bracket-Paris-CP V7 dedicated Current
0254Y950generic drive module-Servers-generic drive-20000GB-NL SAS 12Gb/s-7200rpm-3.5inch-256MB-hot-swap-internal-3.5 inch bracket-Paris-CP V7 server dedicated Current
0255Y347SSD module-Servers-SSD-1920GB-SATA 6Gb/s-mixed read-write-PM897 series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255Y417SSD module-Servers-SSD-480GB-SATA 6Gb/s-read-intensive-PM893 series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255Y418SSD module-Servers-SSD-480GB-SATA 6Gb/s-read-intensive-PM893 series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255Y419SSD module-Servers-SSD-960GB-SATA 6Gb/s-read-intensive-PM893 series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255Y420SSD module-Servers-SSD-960GB-SATA 6Gb/s-read-intensive-PM893 series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255Y421SSD module-Servers-SSD-1920GB-SATA 6Gb/s-read-intensive-PM893 series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255Y422SSD module-Servers-SSD-1920GB-SATA 6Gb/s-read-intensive-PM893 series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255Y423SSD module-Servers-SSD-3840GB-SATA 6Gb/s-read-intensive-PM893 series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255Y424SSD module-Servers-SSD-3840GB-SATA 6Gb/s-read-intensive-PM893 series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255Y427SSD module-Servers-SSD-480GB-SATA 6Gb/s-mixed read-write-PM897 series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255Y428SSD module-Servers-SSD-480GB-SATA 6Gb/s-mixed read-write-PM897 series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255Y429SSD module-Servers-SSD-960GB-SATA 6Gb/s-mixed read-write-PM897 series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255Y430SSD module-Servers-SSD-960GB-SATA 6Gb/s-mixed read-write-PM897 series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255Y431SSD module-Servers-SSD-1920GB-SATA 6Gb/s-mixed read-write-PM897 series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255Y432SSD module-Servers-SSD-3840GB-SATA 6Gb/s-mixed read-write-PM897 series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255Y433SSD module-Servers-SSD-3840GB-SATA 6Gb/s-mixed read-write-PM897 series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255YBMX-002SSD module-Servers-SSD-480GB-SATA 6Gb/s-read-intensive-S4520 series-2.5 inch(2.5 inch bracket)-V7 dedicated-Solidigm Current
0255YBMY-004SSD module-Servers-SSD-480GB-SATA 6Gb/s-read-intensive-S4520 series-2.5 inch(3.5 inch bracket)-V7 dedicated-Solidigm Current
0255YBNA-001SSD module-Servers-SSD-960GB-SATA 6Gb/s-read-intensive-S4520 series-2.5 inch(2.5 inch bracket)-V7 dedicated-Solidigm Current
0255YBNB-004SSD module-Servers-SSD-960GB-SATA 6Gb/s-read-intensive-S4520 series-2.5 inch(3.5 inch bracket)-V7 dedicated-Solidigm Current
0255YBNQSSD module-Servers-SSD-3840GB-SATA 6Gb/s-read-intensive-2.5 inch(2.5 inch bracket)-V7 dedicated-spec code Current
0255YBNQ-002SSD module-Servers-SSD-3840GB-SATA 6Gb/s-read-intensive-S4520 series-2.5 inch(2.5 inch bracket)-V7 dedicated-Solidigm Current
0255YBNRSSD module-Servers-SSD-3840GB-SATA 6Gb/s-read-intensive-2.5 inch(3.5 inch bracket)-V7 dedicated-spec code Current
0255YBNR-002SSD module-Servers-SSD-3840GB-SATA 6Gb/s-read-intensive-S4520 series-2.5 inch(3.5 inch bracket)-V7 dedicated-Solidigm Current
0255YBNSSSD module-Servers-SSD-1920GB-SATA 6Gb/s-read-intensive-2.5 inch(2.5 inch bracket)-V7 dedicated-spec code Current
0255YBNS-001SSD module-Servers-SSD-1920GB-SATA 6Gb/s-read-intensive-S4520 series-2.5 inch(2.5 inch bracket)-V7 dedicated-Solidigm Current
0255YBNTSSD module-Servers-SSD-1920GB-SATA 6Gb/s-read-intensive-2.5 inch(3.5 inch bracket)-V7 dedicated-spec code Current
0255YBNT-004SSD module-Servers-SSD-1920GB-SATA 6Gb/s-read-intensive-S4520 series-2.5 inch(3.5 inch bracket)-V7 dedicated-Solidigm Current
0255YCAKSSD module-Servers-SSD-480GB-SATA 6Gb/s-mixed read-write-2.5 inch(2.5 inch bracket)-V7 dedicated-spec code Current
0255YCAK-001SSD module-Servers-SSD-480GB-SATA 6Gb/s-mixed read-write-S4620 series-2.5 inch(2.5 inch bracket)-V7 dedicated-Solidigm Current
0255YCALSSD module-Servers-SSD-480GB-SATA 6Gb/s-mixed read-write-2.5 inch(3.5 inch bracket)-V7 dedicated-spec code Current
0255YCAL-001SSD module-Servers-SSD-480GB-SATA 6Gb/s-mixed read-write-S4620 series-2.5 inch(3.5 inch bracket)-V7 dedicated-Solidigm Current
0255YCAMSSD module-Servers-SSD-960GB-SATA 6Gb/s-mixed read-write-2.5 inch(2.5 inch bracket)-V7 dedicated-spec code Current
0255YCAM-001SSD module-Servers-SSD-960GB-SATA 6Gb/s-mixed read-write-S4620 series-2.5 inch(2.5 inch bracket)-V7 dedicated-Solidigm Current
0255YCANSSD module-Servers-SSD-960GB-SATA 6Gb/s-mixed read-write-2.5 inch(3.5 inch bracket)-V7 dedicated-spec code Current
0255YCAN-001SSD module-Servers-SSD-960GB-SATA 6Gb/s-mixed read-write-S4620 series-2.5 inch(3.5 inch bracket)-V7 dedicated-Solidigm Current
0255YCAPSSD module-Servers-SSD-1920GB-SATA 6Gb/s-mixed read-write-2.5 inch(2.5 inch bracket)-V7 dedicated-spec code Current
0255YCAP-001SSD module-Servers-SSD-1920GB-SATA 6Gb/s-mixed read-write-S4620 series-2.5 inch(2.5 inch bracket)-V7 dedicated-Solidigm Current
0255YCAQSSD module-Servers-SSD-1920GB-SATA 6Gb/s-mixed read-write-2.5 inch(3.5 inch bracket)-V7 dedicated-spec code Current
0255YCAQ-001SSD module-Servers-SSD-1920GB-SATA 6Gb/s-mixed read-write-S4620 series-2.5 inch(3.5 inch bracket)-V7 dedicated-Solidigm Current
0255YCARSSD module-Servers-SSD-3840GB-SATA 6Gb/s-mixed read-write-2.5 inch(2.5 inch bracket)-V7 dedicated-spec code Current
0255YCAR-001SSD module-Servers-SSD-3840GB-SATA 6Gb/s-mixed read-write-S4620 series-2.5 inch(2.5 inch bracket)-V7 dedicated-Solidigm Current
0255YCASSSD module-Servers-SSD-3840GB-SATA 6Gb/s-mixed read-write-2.5 inch(3.5 inch bracket)-V7 dedicated-spec code Current
0255YCAS-001SSD module-Servers-SSD-3840GB-SATA 6Gb/s-mixed read-write-S4620 series-2.5 inch(3.5 inch bracket)-V7 dedicated-Solidigm Current
0255YDUHSSD module-Servers-SSD-480GB-SATA 6Gb/s-read-intensive-SE006 series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255YDUJSSD module-Servers-SSD-480GB-SATA 6Gb/s-read-intensive-SE006 series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255YDUMSSD module-Servers-SSD-960GB-SATA 6Gb/s-read-intensive-SE006 series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255YDUNSSD module-Servers-SSD-960GB-SATA 6Gb/s-read-intensive-SE006 series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255YDURSSD module-Servers-SSD-1920GB-SATA 6Gb/s-read-intensive-SE006 series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255YDUSSSD module-Servers-SSD-1920GB-SATA 6Gb/s-read-intensive-SE006 series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255YDUWSSD module-Servers-SSD-7680GB-SATA 6Gb/s-read-intensive-SE006 series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255YDUXSSD module-Servers-SSD-7680GB-SATA 6Gb/s-read-intensive-SE006 series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255YDXASSD module-Servers-SSD-3840GB-SATA 6Gb/s-read-intensive-SE006 series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255YDXBSSD module-Servers-SSD-3840GB-SATA 6Gb/s-read-intensive-SE006 series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255YESESSD module-Servers-SSD-960GB-SATA 6Gb/s-mixed read-write-S4620 series-2.5 inch(2.5 inch bracket)-V7 dedicated-Solidigm Current
0255YESSSSD module-Servers-SSD-3840GB-SATA 6Gb/s-read-intensive-PM893 series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255YESTSSD module-Servers-SSD-3840GB-SATA 6Gb/s-read-intensive-PM893 series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255YETESSD module-Servers-SSD-480GB-SATA 6Gb/s-read-intensive-SE006 series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255YETJSSD module-Servers-SSD-480GB-SATA 6Gb/s-read-intensive-SE006 series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255YETMSSD module-Servers-SSD-3840GB-SATA 6Gb/s-mixed read-write-PM897 series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255YETNSSD module-Servers-SSD-3840GB-SATA 6Gb/s-mixed read-write-PM897 series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255YEUNSSD module-Servers-SSD-480GB-SATA 6Gb/s-read-intensive-PM893 series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255YEURSSD module-Servers-SSD-480GB-SATA 6Gb/s-read-intensive-PM893 series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255YEUYSSD module-Servers-SSD-960GB-SATA 6Gb/s-mixed read-write-PM897 series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255YEVCSSD module-Servers-SSD-960GB-SATA 6Gb/s-mixed read-write-PM897 series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255YEVXSSD module-Servers-SSD-3840GB-SATA 6Gb/s-mixed read-write-S4620 series-2.5 inch(2.5 inch bracket)-V7 dedicated-Solidigm Current
0255YEWESSD module-Servers-SSD-3840GB-SATA 6Gb/s-mixed read-write-S4620 series-2.5 inch(3.5 inch bracket)-V7 dedicated-Solidigm Current
0255YEWKSSD module-Servers-SSD-1920GB-SATA 6Gb/s-mixed read-write-S4620 series-2.5 inch(2.5 inch bracket)-V7 dedicated-Solidigm Current
0255YEXBSSD module-Servers-SSD-960GB-SATA 6Gb/s-mixed read-write-S4620 series-2.5 inch(3.5 inch bracket)-V7 dedicated-Solidigm Current
0255YEXFSSD module-Servers-SSD-1920GB-SATA 6Gb/s-read-intensive-SE006 series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255YEXMSSD module-Servers-SSD-1920GB-SATA 6Gb/s-read-intensive-SE006 series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255YEXQSSD module-Servers-SSD-1920GB-SATA 6Gb/s-read-intensive-PM893 series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255YEXRSSD module-Servers-SSD-3840GB-SATA 6Gb/s-read-intensive-SE006 series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255YEXTSSD module-Servers-SSD-1920GB-SATA 6Gb/s-read-intensive-PM893 series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255YEXWSSD module-Servers-SSD-3840GB-SATA 6Gb/s-read-intensive-SE006 series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255YEYMSSD module-Servers-SSD-480GB-SATA 6Gb/s-mixed read-write-S4620 series-2.5 inch(3.5 inch bracket)-V7 dedicated-Solidigm Current
0255YEYPSSD module-Servers-SSD-960GB-SATA 6Gb/s-read-intensive-SE006 series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255YEYQSSD module-Servers-SSD-480GB-SATA 6Gb/s-mixed read-write-S4620 series-2.5 inch(2.5 inch bracket)-V7 dedicated-Solidigm Current
0255YEYRSSD module-Servers-SSD-1920GB-SATA 6Gb/s-mixed read-write-S4620 series-2.5 inch(3.5 inch bracket)-V7 dedicated-Solidigm Current
0255YEYTSSD module-Servers-SSD-960GB-SATA 6Gb/s-read-intensive-SE006 series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255YFACSSD module-Servers-SSD-1920GB-SATA 6Gb/s-mixed read-write-PM897 series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255YFAFSSD module-Servers-SSD-1920GB-SATA 6Gb/s-mixed read-write-PM897 series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255YFALSSD module-Servers-SSD-1920GB-SATA 6Gb/s-read-intensive-S4520 series-2.5 inch(3.5 inch bracket)-V7 dedicated-Solidigm Current
0255YFAMSSD module-Servers-SSD-1920GB-SATA 6Gb/s-read-intensive-S4520 series-2.5 inch(2.5 inch bracket)-V7 dedicated-Solidigm Current
0255YFANSSD module-Servers-SSD-3840GB-SATA 6Gb/s-read-intensive-S4520 series-2.5 inch(3.5 inch bracket)-V7 dedicated-Solidigm Current
0255YFAPSSD module-Servers-SSD-3840GB-SATA 6Gb/s-read-intensive-S4520 series-2.5 inch(2.5 inch bracket)-V7 dedicated-Solidigm Current
0255YFBDSSD module-Servers-SSD-960GB-SATA 6Gb/s-read-intensive-PM893 series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255YFBESSD module-Servers-SSD-960GB-SATA 6Gb/s-read-intensive-PM893 series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255YFCGSSD module-Servers-SSD-480GB-SATA 6Gb/s-read-intensive-S4520 series-2.5 inch(3.5 inch bracket)-V7 dedicated-Solidigm Current
0255YFCHSSD module-Servers-SSD-480GB-SATA 6Gb/s-read-intensive-S4520 series-2.5 inch(2.5 inch bracket)-V7 dedicated-Solidigm Current
0255YFCJSSD module-Servers-SSD-960GB-SATA 6Gb/s-read-intensive-S4520 series-2.5 inch(3.5 inch bracket)-V7 dedicated-Solidigm Current
0255YFCKSSD module-Servers-SSD-960GB-SATA 6Gb/s-read-intensive-S4520 series-2.5 inch(2.5 inch bracket)-V7 dedicated-Solidigm Current
0254Y070generic drive module-Servers-generic drive-14TB-SATA 6.0Gb/s-7.2K rpm-3.5 inch-hot-swap-internal-3.5 inch bracket-V7 server dedicated EOP
0254Y398generic drive module-Servers-generic drive-12000GB-SATA 6.0Gb/s-7200rpm-3.5inch-256MB or above-hot-swap-internal-3.5 inch bracket-WD-V7 dedicated EOM
0254Y399generic drive module-Servers-generic drive-12000GB-SATA 6.0Gb/s-7200rpm-3.5inch-256MB or above-hot-swap-internal-3.5 inch bracket-Seagate-V7 dedicated EOP
0254Y443generic drive module-Servers-generic drive-16000GB-SATA 6.0Gb/s-7.2K rpm-3.5inch-hot-swap-internal-3.5 inch bracket-Toshiba-V7 dedicated EOM
0254Y445generic drive module-Servers-generic drive-16000GB-SATA 6.0Gb/s-7.2K rpm-3.5inch-256MB-hot-swap-internal-3.5 inch bracket-SEAGATE-V7 dedicated EOM
0254Y497generic drive module-Servers-generic drive-16000GB-SATA 6.0Gb/s-7.2K rpm-3.5inch-hot-swap-internal-3.5 inch bracket-WD-V7 dedicated EOM
0254Y498generic drive module-Servers-generic drive-20000GB-SATA 6.0Gb/s-7.2K rpm-256MB-3.5 inch-hot-swap-internal-3.5 inch bracket-WD-V7 dedicated EOM
0254Y499generic drive module-Servers-generic drive-20000GB-SATA 6.0Gb/s-7.2K rpm-256MB-3.5 inch-hot-swap-internal-3.5 inch bracket-Seagate-V7 dedicated EOP
0255Y397SSD module-Servers-SSD-240GB-SATA 6Gb/s-read-intensive-S4520 series-2.5 inch(2.5 inch bracket)-V7 dedicated EOM
0255Y398SSD module-Servers-SSD-240GB-SATA 6Gb/s-read-intensive-S4520 series-2.5 inch(3.5 inch bracket)-V7 dedicated EOM
0255Y399SSD module-Servers-SSD-480GB-SATA 6Gb/s-read-intensive-S4520 series-2.5 inch(2.5 inch bracket)-V7 dedicated EOM
0255Y400SSD module-Servers-SSD-480GB-SATA 6Gb/s-read-intensive-S4520 series-2.5 inch(3.5 inch bracket)-V7 dedicated EOM
0255Y401SSD module-Servers-SSD-960GB-SATA 6Gb/s-read-intensive-S4520 series-2.5 inch(2.5 inch bracket)-V7 dedicated EOM
0255Y402SSD module-Servers-SSD-960GB-SATA 6Gb/s-read-intensive-S4520 series-2.5 inch(3.5 inch bracket)-V7 dedicated EOM
0255Y403SSD module-Servers-SSD-1920GB-SATA 6Gb/s-read-intensive-S4520 series-2.5 inch(2.5 inch bracket)-V7 dedicated EOM
0255Y404SSD module-Servers-SSD-1920GB-SATA 6Gb/s-read-intensive-S4520 series-2.5 inch(3.5 inch bracket)-V7 dedicated EOM
0255Y405SSD module-Servers-SSD-3840GB-SATA 6Gb/s-read-intensive-S4520 series-2.5 inch(2.5 inch bracket)-V7 dedicated EOM
0255Y406SSD module-Servers-SSD-3840GB-SATA 6Gb/s-read-intensive-S4520 series-2.5 inch(3.5 inch bracket)-V7 dedicated EOM
0255Y407SSD module-Servers-SSD-480GB-SATA 6Gb/s-mixed read-write-S4620 series-2.5 inch(2.5 inch bracket)-V7 dedicated EOM
0255Y408SSD module-Servers-SSD-480GB-SATA 6Gb/s-mixed read-write-S4620 series-2.5 inch(3.5 inch bracket)-V7 dedicated EOM
0255Y409SSD module-Servers-SSD-960GB-SATA 6Gb/s-mixed read-write-S4620 series-2.5 inch(2.5 inch bracket)-V7 dedicated EOM
0255Y410SSD module-Servers-SSD-960GB-SATA 6Gb/s-mixed read-write-S4620 series-2.5 inch(3.5 inch bracket)-V7 dedicated EOM
0255Y411SSD module-Servers-SSD-1920GB-SATA 6Gb/s-mixed read-write-S4620 series-2.5 inch(2.5 inch bracket)-V7 dedicated EOM
0255Y412SSD module-Servers-SSD-1920GB-SATA 6Gb/s-mixed read-write-S4620 series-2.5 inch(3.5 inch bracket)-V7 dedicated EOM
0255Y413SSD module-Servers-SSD-3840GB-SATA 6Gb/s-mixed read-write-S4620 series-2.5 inch(2.5 inch bracket)-V7 dedicated EOM
0255Y414SSD module-Servers-SSD-3840GB-SATA 6Gb/s-mixed read-write-S4620 series-2.5 inch(3.5 inch bracket)-V7 dedicated EOM
0255Y415SSD module-Servers-SSD-240GB-SATA 6Gb/s-read-intensive-PM893 series-2.5 inch(2.5 inch bracket)-V7 dedicated EOP
0255Y416SSD module-Servers-SSD-240GB-SATA 6Gb/s-read-intensive-PM893 series-2.5 inch(3.5 inch bracket)-V7 dedicated EOP
0255Y444SSD module-Servers-SSD-480GB-SATA 6Gb/s-read-intensive-SE005 series-2.5 inch(2.5 inch bracket)-V7 dedicated EOM
0255Y445SSD module-Servers-SSD-480GB-SATA 6Gb/s-read-intensive-SE005 series-2.5 inch(3.5 inch bracket)-V7 dedicated EOM
0255Y446SSD module-Servers-SSD-960GB-SATA 6Gb/s-read-intensive-SE005 series-2.5 inch(2.5 inch bracket)-V7 dedicated EOM
0255Y447SSD module-Servers-SSD-960GB-SATA 6Gb/s-read-intensive-SE005 series-2.5 inch(3.5 inch bracket)-V7 dedicated EOM
0255Y448SSD module-Servers-SSD-1920GB-SATA 6Gb/s-read-intensive-SE005 series-2.5 inch(2.5 inch bracket)-V7 dedicated EOM
0255Y449SSD module-Servers-SSD-1920GB-SATA 6Gb/s-read-intensive-SE005 series-2.5 inch(3.5 inch bracket)-V7 dedicated EOM
0255Y998SSD module-Servers-SSD-960GB-SAS 12Gb/s-read-intensive-UM611a-Y series-2.5 inch(2.5 inch bracket)-shell optimized-V7 dedicated EOM
0255Y999SSD module-Servers-SSD-960GB-SAS 12Gb/s-read-intensive-UM611a-Y series-2.5 inch(3.5 inch bracket)-shell optimized-V7 dedicated EOM
0255YAAASSD module-Servers-SSD-1920GB-SAS 12Gb/s-read-intensive-UM611a-Y series-2.5 inch(2.5 inch bracket)-shell optimized-V7 dedicated EOP
0255YAABSSD module-Servers-SSD-1920GB-SAS 12Gb/s-read-intensive-UM611a-Y series-2.5 inch(3.5 inch bracket)-shell optimized-V7 dedicated EOM
0255YAACSSD module-Servers-SSD-3840GB-SAS 12Gb/s-read-intensive-UM611a-Y series-2.5 inch(2.5 inch bracket)-shell optimized-V7 dedicated EOP
0255Y305SSD Module,Servers,SSD,7680GB,NVMe PCIe,Read Intensive,PM9A3 Series,2.5inch(2.5inch Drive Bay),V7 dedicated Current Field replaceable
0255Y301SSD Module,Servers,SSD,1920GB,NVMe PCIe,Read Intensive,PM9A3 Series,2.5inch(2.5inch Drive Bay),V7 dedicated Current Field replaceable
0255Y303SSD Module,Servers,SSD,3840GB,NVMe PCIe,Read Intensive,PM9A3 Series,2.5inch(2.5inch Drive Bay),V7 dedicated Current Field replaceable
0255Y454SSD Module,Servers,SSD,960GB,SATA 6Gb/s,Read Intensive,ES500 Series,2.5inch(2.5inch Drive Bay),V7 dedicated Current Field replaceable
0255Y455SSD Module,Servers,SSD,960GB,SATA 6Gb/s,Read Intensive,ES500 Series,2.5inch(3.5inch Drive Bay),V7 dedicated Current Field replaceable
0255Y456SSD Module,Servers,SSD,1920GB,SATA 6Gb/s,Read Intensive,ES500 Series,2.5inch(2.5inch Drive Bay),V7 dedicated Current Field replaceable
0255Y457SSD Module,Servers,SSD,1920GB,SATA 6Gb/s,Read Intensive,ES500 Series,2.5inch(3.5inch Drive Bay),V7 dedicated Current Field replaceable
0255Y450SSD Module,Servers,SSD,240GB,SATA 6Gb/s,Read Intensive,ES500 Series,2.5inch(2.5inch Drive Bay),V7 dedicated Current Field replaceable
0255Y451SSD Module,Servers,SSD,240GB,SATA 6Gb/s,Read Intensive,ES500 Series,2.5inch(3.5inch Drive Bay),V7 dedicated Current Field replaceable
0255Y452SSD Module,Servers,SSD,480GB,SATA 6Gb/s,Read Intensive,ES500 Series,2.5inch(2.5inch Drive Bay),V7 dedicated Current Field replaceable
0255Y453SSD Module,Servers,SSD,480GB,SATA 6Gb/s,Read Intensive,ES500 Series,2.5inch(3.5inch Drive Bay),V7 dedicated Current Field replaceable
0255Y627SSD Module,Servers,SSD,6400GB,NVMe PCIe,Mixed Use,UH831a,Y Series,2.5inch(3.5inch Drive Bay),V7 dedicated Current Field replaceable
0255Y902SSD Module,Servers,SSD,1600GB,NVMe PCIe,Mixed Use,EP600 Series,2.5inch(3.5inch Drive Bay),V7 dedicated,Global Current Field replaceable
0255Y904SSD Module,Servers,SSD,3200GB,NVMe PCIe,Mixed Use,EP600 Series,2.5inch(3.5inch Drive Bay),V7 dedicated,Global Current Field replaceable
0255Y469SSD Module,Servers,SSD,7680GB,NVMe PCIe,Read Intensive,P5520 Series,2.5inch(3.5inch Drive Bay),V7 dedicated Current Field replaceable
0255Y304SSD Module,Servers,SSD,3840GB,NVMe PCIe,Read Intensive,PM9A3 Series,2.5inch(3.5inch Drive Bay),V7 dedicated Current Field replaceable
0255Y623SSD Module,Servers,SSD,1600GB,NVMe PCIe,Mixed Use,UH831a,Y Series,2.5inch(3.5inch Drive Bay),V7 dedicated Current Field replaceable
0255Y306SSD Module,Servers,SSD,7680GB,NVMe PCIe,Read Intensive,PM9A3 Series,2.5inch(3.5inch Drive Bay),V7 dedicated Current Field replaceable
0255Y625SSD Module,Servers,SSD,3200GB,NVMe PCIe,Mixed Use,UH831a,Y Series,2.5inch(3.5inch Drive Bay),V7 dedicated Current Field replaceable
0255Y900SSD Module,Servers,SSD,7680GB,NVMe PCIe,Read Intensive,EP500 Series,2.5inch(3.5inch Drive Bay),V7 dedicated,Global Current Field replaceable
0255Y906SSD Module,Servers,SSD,6400GB,NVMe PCIe,Mixed Use,EP600 Series,2.5inch(3.5inch Drive Bay),V7 dedicated,Global Current Field replaceable
0255Y465SSD Module,Servers,SSD,1920GB,NVMe PCIe,Read Intensive,P5520 Series,2.5inch(3.5inch Drive Bay),V7 dedicated Current Field replaceable
0255Y300SSD Module,Servers,SSD,960GB,NVMe PCIe,Read Intensive,PM9A3 Series,2.5inch(3.5inch Drive Bay),V7 dedicated Current Field replaceable
0255Y467SSD Module,Servers,SSD,3840GB,NVMe PCIe,Read Intensive,P5520 Series,2.5inch(3.5inch Drive Bay),V7 dedicated Current Field replaceable
0255Y302SSD Module,Servers,SSD,1920GB,NVMe PCIe,Read Intensive,PM9A3 Series,2.5inch(3.5inch Drive Bay),V7 dedicated Current Field replaceable
0255Y898SSD Module,Servers,SSD,3840GB,NVMe PCIe,Read Intensive,EP500 Series,2.5inch(3.5inch Drive Bay),V7 dedicated,Global Current Field replaceable
0255YBAASSD Module,Servers,SSD,6400GB,NVMe PCIe,Mixed Use,PE321 Series,2.5inch(3.5inch Drive Bay),V7 dedicated Current Field replaceable
0255Y896SSD Module,Servers,SSD,1920GB,NVMe PCIe,Read Intensive,EP500 Series,2.5inch(3.5inch Drive Bay),V7 dedicated,Global Current Field replaceable
0255YAYXSSD Module,Servers,SSD,3200GB,NVMe PCIe,Mixed Use,PE321 Series,2.5inch(3.5inch Drive Bay),V7 dedicated Current Field replaceable
0255YCHXSSD Module,Servers,SSD,1920GB,NVMe PCIe,Read Intensive,PM9A3 Series,2.5inch(3.5inch Drive Bay),V7 dedicated Current Field replaceable
0255YCHWSSD Module,Servers,SSD,1920GB,NVMe PCIe,Read Intensive,2.5inch(3.5inch Drive Bay),V7 dedicated Current Field replaceable
0255YBVHSSD Module,Servers,SSD,7680GB,NVMe PCIe,Read Intensive,SP520 Series,2.5inch(2.5inch Drive Bay),V7 dedicated Current Field replaceable
0255YBVGSSD Module,Servers,SSD,3840GB,NVMe PCIe,Read Intensive,SP520 Series,2.5inch(3.5inch Drive Bay),V7 dedicated Current Field replaceable
0255YBVJSSD Module,Servers,SSD,7680GB,NVMe PCIe,Read Intensive,SP520 Series,2.5inch(3.5inch Drive Bay),V7 dedicated Current Field replaceable
0255YBVDSSD Module,Servers,SSD,1920GB,NVMe PCIe,Read Intensive,SP520 Series,2.5inch(2.5inch Drive Bay),V7 dedicated Current Field replaceable
0255YBVFSSD Module,Servers,SSD,3840GB,NVMe PCIe,Read Intensive,SP520 Series,2.5inch(2.5inch Drive Bay),V7 dedicated Current Field replaceable
0255YBVESSD Module,Servers,SSD,1920GB,NVMe PCIe,Read Intensive,SP520 Series,2.5inch(3.5inch Drive Bay),V7 dedicated Current Field replaceable
0255YBUNSSD Module,Servers,SSD,6400GB,NVMe PCIe,Mixed Use,SP620 Series,2.5inch(2.5inch Drive Bay),V7 dedicated Current Field replaceable
0255YBUQSSD Module,Servers,SSD,3200GB,NVMe PCIe,Mixed Use,SP620 Series,2.5inch(2.5inch Drive Bay),V7 dedicated Current Field replaceable
0255YBUPSSD Module,Servers,SSD,6400GB,NVMe PCIe,Mixed Use,SP620 Series,2.5inch(3.5inch Drive Bay),V7 dedicated Current Field replaceable
0255Y899SSD Module,Servers,SSD,7680GB,NVMe PCIe,Read Intensive,EP500 Series,2.5inch(2.5inch Drive Bay),V7 dedicated,Global Current Field replaceable
0255YBUSSSD Module,Servers,SSD,1600GB,NVMe PCIe,Mixed Use,SP620 Series,2.5inch(2.5inch Drive Bay),V7 dedicated Current Field replaceable
0255YBURSSD Module,Servers,SSD,3200GB,NVMe PCIe,Mixed Use,SP620 Series,2.5inch(3.5inch Drive Bay),V7 dedicated Current Field replaceable
0255YBUTSSD Module,Servers,SSD,1600GB,NVMe PCIe,Mixed Use,SP620 Series,2.5inch(3.5inch Drive Bay),V7 dedicated Current Field replaceable
0255Y299SSD Module,Servers,SSD,960GB,NVMe PCIe,Read Intensive,PM9A3 Series,2.5inch(2.5inch Drive Bay),V7 dedicated Current Field replaceable
0255Y470SSD Module,Servers,SSD,1600GB,NVMe PCIe,Mixed Use,EP600 Series,2.5inch(2.5inch Drive Bay),V7 dedicated Current Field replaceable
0255Y476SSD Module,Servers,SSD,1600GB,NVMe PCIe,Mixed Use,P5620 Series,2.5inch(2.5inch Drive Bay),V7 dedicated Current Field replaceable
0255Y477SSD Module,Servers,SSD,1600GB,NVMe PCIe,Mixed Use,P5620 Series,2.5inch(3.5inch Drive Bay),V7 dedicated Current Field replaceable
0255Y478SSD Module,Servers,SSD,3200GB,NVMe PCIe,Mixed Use,P5620 Series,2.5inch(2.5inch Drive Bay),V7 dedicated Current Field replaceable
0255Y479SSD Module,Servers,SSD,3200GB,NVMe PCIe,Mixed Use,P5620 Series,2.5inch(3.5inch Drive Bay),V7 dedicated Current Field replaceable
0255Y472SSD Module,Servers,SSD,3200GB,NVMe PCIe,Mixed Use,EP600 Series,2.5inch(2.5inch Drive Bay),V7 dedicated Current Field replaceable
0255Y474SSD Module,Servers,SSD,6400GB,NVMe PCIe,Mixed Use,EP600 Series,2.5inch(2.5inch Drive Bay),V7 dedicated Current Field replaceable
0255Y903SSD Module,Servers,SSD,3200GB,NVMe PCIe,Mixed Use,EP600 Series,2.5inch(2.5inch Drive Bay),V7 dedicated,Global Current Field replaceable
0255Y905SSD Module,Servers,SSD,6400GB,NVMe PCIe,Mixed Use,EP600 Series,2.5inch(2.5inch Drive Bay),V7 dedicated,Global Current Field replaceable
0255Y901SSD Module,Servers,SSD,1600GB,NVMe PCIe,Mixed Use,EP600 Series,2.5inch(2.5inch Drive Bay),V7 dedicated,Global Current Field replaceable
0255YBARSSD Module,Servers,SSD,3840GB,NVMe PCIe,Read Intensive,PE321 Series,2.5inch(3.5inch Drive Bay),V7 dedicated Current Field replaceable
0255Y466SSD Module,Servers,SSD,3840GB,NVMe PCIe,Read Intensive,P5520 Series,2.5inch(2.5inch Drive Bay),V7 dedicated Current Field replaceable
0255Y468SSD Module,Servers,SSD,7680GB,NVMe PCIe,Read Intensive,P5520 Series,2.5inch(2.5inch Drive Bay),V7 dedicated Current Field replaceable
0255Y341SSD Module,Servers,SSD,7680GB,NVMe PCIe,Read Intensive,EP500 Series,2.5inch(2.5inch Drive Bay),V7 dedicated Current Field replaceable
0255YBAQSSD Module,Servers,SSD,3840GB,NVMe PCIe,Read Intensive,PE321 Series,2.5inch(2.5inch Drive Bay),V7 dedicated Current Field replaceable
0255Y464SSD Module,Servers,SSD,1920GB,NVMe PCIe,Read Intensive,P5520 Series,2.5inch(2.5inch Drive Bay),V7 dedicated Current Field replaceable
0255Y337SSD Module,Servers,SSD,1920GB,NVMe PCIe,Read Intensive,EP500 Series,2.5inch(2.5inch Drive Bay),V7 dedicated Current Field replaceable
0255Y339SSD Module,Servers,SSD,3840GB,NVMe PCIe,Read Intensive,EP500 Series,2.5inch(2.5inch Drive Bay),V7 dedicated Current Field replaceable
0255Y895SSD Module,Servers,SSD,1920GB,NVMe PCIe,Read Intensive,EP500 Series,2.5inch(2.5inch Drive Bay),V7 dedicated,Global Current Field replaceable
0255Y897SSD Module,Servers,SSD,3840GB,NVMe PCIe,Read Intensive,EP500 Series,2.5inch(2.5inch Drive Bay),V7 dedicated,Global Current Field replaceable
0255Y480SSD Module,Servers,SSD,6400GB,NVMe PCIe,Mixed Use,P5620 Series,2.5inch(2.5inch Drive Bay),V7 dedicated Current Field replaceable
0255Y481SSD Module,Servers,SSD,6400GB,NVMe PCIe,Mixed Use,P5620 Series,2.5inch(3.5inch Drive Bay),V7 dedicated Current Field replaceable
0255YAYWSSD Module,Servers,SSD,3200GB,NVMe PCIe,Mixed Use,PE321 Series,2.5inch(2.5inch Drive Bay),V7 dedicated Current Field replaceable
0255YAYYSSD Module,Servers,SSD,6400GB,NVMe PCIe,Mixed Use,PE321 Series,2.5inch(2.5inch Drive Bay),V7 dedicated Current Field replaceable
P/NDescription / SpecificationStatus
0255Y299SSD module-Servers-SSD-960GB-NVMe PCIe-read-intensive-PM9A3 series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255Y300SSD module-Servers-SSD-960GB-NVMe PCIe-read-intensive-PM9A3 series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255Y301SSD module-Servers-SSD-1920GB-NVMe PCIe-read-intensive-PM9A3 series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255Y302SSD module-Servers-SSD-1920GB-NVMe PCIe-read-intensive-PM9A3 series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255Y303SSD module-Servers-SSD-3840GB-NVMe PCIe-read-intensive-PM9A3 series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255Y304SSD module-Servers-SSD-3840GB-NVMe PCIe-read-intensive-PM9A3 series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255Y305SSD module-Servers-SSD-7680GB-NVMe PCIe-read-intensive-PM9A3 series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255Y306SSD module-Servers-SSD-7680GB-NVMe PCIe-read-intensive-PM9A3 series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255Y623SSD module-Servers-SSD-1600GB-NVMe PCIe-mixed read-write-UH831a series-Y series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255Y688SSD module-Servers-SSD-800GB-NVMe PCIe-write-intensive-P5800X series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255Y896SSD module-Servers-SSD-1920GB-NVMe PCIe-read-intensive-EP500 series-2.5 inch(3.5 inch bracket)-V7 dedicated-global Current
0255Y897SSD module-Servers-SSD-3840GB-NVMe PCIe-read-intensive-EP500 series-2.5 inch(2.5 inch bracket)-V7 dedicated-global Current
0255Y898SSD module-Servers-SSD-3840GB-NVMe PCIe-read-intensive-EP500 series-2.5 inch(3.5 inch bracket)-V7 dedicated-global Current
0255Y902SSD module-Servers-SSD-1600GB-NVMe PCIe-mixed read-write-EP600 series-2.5 inch(3.5 inch bracket)-V7 dedicated-global Current
0255YAALSSD module-Servers-SSD-800GB-NVMe PCIe-write-intensive-P5800X series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255YAYUSSD module-Servers-SSD-1600GB-NVMe PCIe-mixed read-write-PE321 series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255YAYVSSD module-Servers-SSD-1600GB-NVMe PCIe-mixed read-write-PE321 series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255YAYWSSD module-Servers-SSD-3200GB-NVMe PCIe-mixed read-write-PE321 series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255YAYXSSD module-Servers-SSD-3200GB-NVMe PCIe-mixed read-write-PE321 series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255YAYYSSD module-Servers-SSD-6400GB-NVMe PCIe-mixed read-write-PE321 series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255YBAASSD module-Servers-SSD-6400GB-NVMe PCIe-mixed read-write-PE321 series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255YBANSSD module-Servers-SSD-1920GB-NVMe PCIe-read-intensive-PE321 series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255YBAPSSD module-Servers-SSD-1920GB-NVMe PCIe-read-intensive-PE321 series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255YBAQSSD module-Servers-SSD-3840GB-NVMe PCIe-read-intensive-PE321 series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255YBARSSD module-Servers-SSD-3840GB-NVMe PCIe-read-intensive-PE321 series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255YBASSSD module-Servers-SSD-7680GB-NVMe PCIe-read-intensive-PE321 series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255YBATSSD module-Servers-SSD-7680GB-NVMe PCIe-read-intensive-PE321 series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255YBUNSSD module-Servers-SSD-6400GB-NVMe PCIe-mixed read-write-SP620 series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255YBUPSSD module-Servers-SSD-6400GB-NVMe PCIe-mixed read-write-SP620 series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255YBUQSSD module-Servers-SSD-3200GB-NVMe PCIe-mixed read-write-SP620 series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255YBURSSD module-Servers-SSD-3200GB-NVMe PCIe-mixed read-write-SP620 series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255YBUSSSD module-Servers-SSD-1600GB-NVMe PCIe-mixed read-write-SP620 series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255YBUTSSD module-Servers-SSD-1600GB-NVMe PCIe-mixed read-write-SP620 series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255YBVDSSD module-Servers-SSD-1920GB-NVMe PCIe-read-intensive-SP520 series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255YBVESSD module-Servers-SSD-1920GB-NVMe PCIe-read-intensive-SP520 series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255YBVFSSD module-Servers-SSD-3840GB-NVMe PCIe-read-intensive-SP520 series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255YBVGSSD module-Servers-SSD-3840GB-NVMe PCIe-read-intensive-SP520 series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255YBVHSSD module-Servers-SSD-7680GB-NVMe PCIe-read-intensive-SP520 series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255YBVJSSD module-Servers-SSD-7680GB-NVMe PCIe-read-intensive-SP520 series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255YCEVSSD module-Servers-SSD-3840GB-NVMe PCIe-read-intensive-2.5 inch(2.5 inch bracket)-V7 dedicated-spec code Current
0255YCEV-001SSD module-Servers-SSD-3840GB-NVMe PCIe-read-intensive-P5520 series-2.5 inch(2.5 inch bracket)-V7 dedicated-Solidigm Current
0255YCEV-004SSD module-Servers-SSD-3840GB-NVMe PCIe-read-intensive-PM9A3 series-2.5 inch(2.5 inch bracket)-V7 dedicated-SAMSUNG-international edition Current
0255YCEWSSD module-Servers-SSD-3840GB-NVMe PCIe-read-intensive-2.5 inch(3.5 inch bracket)-V7 dedicated-spec code Current
0255YCEW-001SSD module-Servers-SSD-3840GB-NVMe PCIe-read-intensive-P5520 series-2.5 inch(3.5 inch bracket)-V7 dedicated-Solidigm Current
0255YCEW-004SSD module-Servers-SSD-3840GB-NVMe PCIe-read-intensive-PM9A3 series-2.5 inch(3.5 inch bracket)-V7 dedicated-SAMSUNG-international edition Current
0255YCEXSSD module-Servers-SSD-7680GB-NVMe PCIe-read-intensive-2.5 inch(2.5 inch bracket)-V7 dedicated-spec code Current
0255YCEX-002SSD module-Servers-SSD-7680GB-NVMe PCIe-read-intensive-P5520 series-2.5 inch(2.5 inch bracket)-V7 dedicated-Solidigm Current
0255YCEX-006SSD module-Servers-SSD-7680GB-NVMe PCIe-read-intensive-PM9A3 series-2.5 inch(2.5 inch bracket)-V7 dedicated-SAMSUNG-international edition Current
0255YCEYSSD module-Servers-SSD-7680GB-NVMe PCIe-read-intensive-2.5 inch(3.5 inch bracket)-V7 dedicated-spec code Current
0255YCEY-001SSD module-Servers-SSD-7680GB-NVMe PCIe-read-intensive-P5520 series-2.5 inch(3.5 inch bracket)-V7 dedicated-Solidigm Current
0255YCEY-004SSD module-Servers-SSD-7680GB-NVMe PCIe-read-intensive-PM9A3 series-2.5 inch(3.5 inch bracket)-V7 dedicated-SAMSUNG-international edition Current
0255YCFA-001SSD module-Servers-SSD-1600GB-NVMe PCIe-mixed read-write-P5620 series-2.5 inch(2.5 inch bracket)-V7 dedicated-Solidigm Current
0255YCFBSSD module-Servers-SSD-1600GB-NVMe PCIe-mixed read-write-2.5 inch(3.5 inch bracket)-V7 dedicated-spec code Current
0255YCFB-001SSD module-Servers-SSD-1600GB-NVMe PCIe-mixed read-write-P5620 series-2.5 inch(3.5 inch bracket)-V7 dedicated-Solidigm Current
0255YCFC-001SSD module-Servers-SSD-3200GB-NVMe PCIe-mixed read-write-P5620 series-2.5 inch(2.5 inch bracket)-V7 dedicated-Solidigm Current
0255YCFDSSD module-Servers-SSD-3200GB-NVMe PCIe-mixed read-write-2.5 inch(3.5 inch bracket)-V7 dedicated-spec code Current
0255YCFD-001SSD module-Servers-SSD-3200GB-NVMe PCIe-mixed read-write-P5620 series-2.5 inch(3.5 inch bracket)-V7 dedicated-Solidigm Current
0255YCFE-001SSD module-Servers-SSD-6400GB-NVMe PCIe-mixed read-write-P5620 series-2.5 inch(2.5 inch bracket)-V7 dedicated-Solidigm Current
0255YCFFSSD module-Servers-SSD-6400GB-NVMe PCIe-mixed read-write-2.5 inch(3.5 inch bracket)-V7 dedicated-spec code Current
0255YCFF-001SSD module-Servers-SSD-6400GB-NVMe PCIe-mixed read-write-P5620 series-2.5 inch(3.5 inch bracket)-V7 dedicated-Solidigm Current
0255YCFQSSD module-Servers-SSD-1920GB-NVMe PCIe-read-intensive-2.5 inch(2.5 inch bracket)-V7 dedicated-spec code Current
0255YCFQ-001SSD module-Servers-SSD-1920GB-NVMe PCIe-read-intensive-P5520 series-2.5 inch(2.5 inch bracket)-V7 dedicated-Solidigm Current
0255YCFRSSD module-Servers-SSD-1920GB-NVMe PCIe-read-intensive-2.5 inch(3.5 inch bracket)-V7 dedicated-spec code Current
0255YCFR-001SSD module-Servers-SSD-1920GB-NVMe PCIe-read-intensive-P5520 series-2.5 inch(3.5 inch bracket)-V7 dedicated-Solidigm Current
0255YEUASSD module-Servers-SSD-1920GB-NVMe PCIe-read-intensive-PE321 series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255YEUBSSD module-Servers-SSD-1920GB-NVMe PCIe-read-intensive-PE321 series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255YEUXSSD module-Servers-SSD-1920GB-NVMe PCIe-read-intensive-P5520 series-2.5 inch(2.5 inch bracket)-V7 dedicated-Solidigm Current
0255YEVBSSD module-Servers-SSD-1920GB-NVMe PCIe-read-intensive-P5520 series-2.5 inch(3.5 inch bracket)-V7 dedicated-Solidigm Current
0255YEVHSSD module-Servers-SSD-3200GB-NVMe PCIe-mixed read-write-PE321 series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255YEVJSSD module-Servers-SSD-3200GB-NVMe PCIe-mixed read-write-PE321 series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255YEWASSD module-Servers-SSD-3840GB-NVMe PCIe-read-intensive-PE321 series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255YEWCSSD module-Servers-SSD-3840GB-NVMe PCIe-read-intensive-PE321 series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255YEWLSSD module-Servers-SSD-1600GB-NVMe PCIe-mixed read-write-P5620 series-2.5 inch(2.5 inch bracket)-V7 dedicated-Solidigm Current
0255YEWNSSD module-Servers-SSD-1600GB-NVMe PCIe-mixed read-write-P5620 series-2.5 inch(3.5 inch bracket)-V7 dedicated-Solidigm Current
0255YEWRSSD module-Servers-SSD-7680GB-NVMe PCIe-read-intensive-PE321 series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255YEWVSSD module-Servers-SSD-1600GB-NVMe PCIe-mixed read-write-PE321 series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255YEWWSSD module-Servers-SSD-7680GB-NVMe PCIe-read-intensive-PE321 series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255YEWXSSD module-Servers-SSD-1600GB-NVMe PCIe-mixed read-write-PE321 series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255YFAWSSD module-Servers-SSD-6400GB-NVMe PCIe-mixed read-write-PE321 series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255YFAXSSD module-Servers-SSD-6400GB-NVMe PCIe-mixed read-write-PE321 series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255YFBVSSD module-Servers-SSD-3840GB-NVMe PCIe-read-intensive-P5520 series-2.5 inch(3.5 inch bracket)-V7 dedicated-Solidigm Current
0255YFCASSD module-Servers-SSD-3840GB-NVMe PCIe-read-intensive-P5520 series-2.5 inch(2.5 inch bracket)-V7 dedicated-Solidigm Current
0255YFCBSSD module-Servers-SSD-3200GB-NVMe PCIe-mixed read-write-P5620 series-2.5 inch(3.5 inch bracket)-V7 dedicated-Solidigm Current
0255YFCFSSD module-Servers-SSD-3200GB-NVMe PCIe-mixed read-write-P5620 series-2.5 inch(2.5 inch bracket)-V7 dedicated-Solidigm Current
0255YFCVSSD module-Servers-SSD-7680GB-NVMe PCIe-read-intensive-PM9A3 series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255YFCYSSD module-Servers-SSD-7680GB-NVMe PCIe-read-intensive-PM9A3 series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255YFDKSSD module-Servers-SSD-1920GB-NVMe PCIe-read-intensive-PM9A3 series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255YFDNSSD module-Servers-SSD-1920GB-NVMe PCIe-read-intensive-PM9A3 series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255YFDVSSD module-Servers-SSD-3840GB-NVMe PCIe-read-intensive-PM9A3 series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255YFDWSSD module-Servers-SSD-3840GB-NVMe PCIe-read-intensive-PM9A3 series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255YFEGSSD module-Servers-SSD-960GB-NVMe PCIe-read-intensive-PM9A3 series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255YFEHSSD module-Servers-SSD-960GB-NVMe PCIe-read-intensive-PM9A3 series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255Y464SSD module-Servers-SSD-1920GB-NVMe PCIe-read-intensive-P5520 series-2.5 inch(2.5 inch bracket)-V7 dedicated EOM
0255Y465SSD module-Servers-SSD-1920GB-NVMe PCIe-read-intensive-P5520 series-2.5 inch(3.5 inch bracket)-V7 dedicated EOM
0255Y466SSD module-Servers-SSD-3840GB-NVMe PCIe-read-intensive-P5520 series-2.5 inch(2.5 inch bracket)-V7 dedicated EOM
0255Y467SSD module-Servers-SSD-3840GB-NVMe PCIe-read-intensive-P5520 series-2.5 inch(3.5 inch bracket)-V7 dedicated EOM
0255Y468SSD module-Servers-SSD-7680GB-NVMe PCIe-read-intensive-P5520 series-2.5 inch(2.5 inch bracket)-V7 dedicated EOM
0255Y469SSD module-Servers-SSD-7680GB-NVMe PCIe-read-intensive-P5520 series-2.5 inch(3.5 inch bracket)-V7 dedicated EOM
0255Y476SSD module-Servers-SSD-1600GB-NVMe PCIe-mixed read-write-P5620 series-2.5 inch(2.5 inch bracket)-V7 dedicated EOM
0255Y477SSD module-Servers-SSD-1600GB-NVMe PCIe-mixed read-write-P5620 series-2.5 inch(3.5 inch bracket)-V7 dedicated EOM
0255Y478SSD module-Servers-SSD-3200GB-NVMe PCIe-mixed read-write-P5620 series-2.5 inch(2.5 inch bracket)-V7 dedicated EOM
0255Y479SSD module-Servers-SSD-3200GB-NVMe PCIe-mixed read-write-P5620 series-2.5 inch(3.5 inch bracket)-V7 dedicated EOM
0255Y480SSD module-Servers-SSD-6400GB-NVMe PCIe-mixed read-write-P5620 series-2.5 inch(2.5 inch bracket)-V7 dedicated EOM
0255Y481SSD module-Servers-SSD-6400GB-NVMe PCIe-mixed read-write-P5620 series-2.5 inch(3.5 inch bracket)-V7 dedicated EOM
0255Y622SSD module-Servers-SSD-1600GB-NVMe PCIe-mixed read-write-UH831a series-Y-2.5 inch(2.5 inch bracket)-V7 dedicated EOM
0255Y624SSD module-Servers-SSD-3200GB-NVMe PCIe-mixed read-write-UH831a series-Y-2.5 inch(2.5 inch bracket)-V7 dedicated EOM
0255Y625SSD module-Servers-SSD-3200GB-NVMe PCIe-mixed read-write-UH831a series-Y series-2.5 inch(3.5 inch bracket)-V7 dedicated EOM
0255Y626SSD module-Servers-SSD-6400GB-NVMe PCIe-mixed read-write-UH831a series-Y-2.5 inch(2.5 inch bracket)-V7 dedicated EOM
0255Y627SSD module-Servers-SSD-6400GB-NVMe PCIe-mixed read-write-UH831a series-Y series-2.5 inch(3.5 inch bracket)-V7 dedicated EOM
0255Y895SSD module-Servers-SSD-1920GB-NVMe PCIe-read-intensive-EP500 series-2.5 inch(2.5 inch bracket)-V7 dedicated-global EOM
0255Y899SSD module-Servers-SSD-7680GB-NVMe PCIe-read-intensive-EP500 series-2.5 inch(2.5 inch bracket)-V7 dedicated-global EOM
0255Y900SSD module-Servers-SSD-7680GB-NVMe PCIe-read-intensive-EP500 series-2.5 inch(3.5 inch bracket)-V7 dedicated-global EOM
0255Y901SSD module-Servers-SSD-1600GB-NVMe PCIe-mixed read-write-EP600 series-2.5 inch(2.5 inch bracket)-V7 dedicated-global EOM
0255Y903SSD module-Servers-SSD-3200GB-NVMe PCIe-mixed read-write-EP600 series-2.5 inch(2.5 inch bracket)-V7 dedicated-global EOM
0255Y904SSD module-Servers-SSD-3200GB-NVMe PCIe-mixed read-write-EP600 series-2.5 inch(3.5 inch bracket)-V7 dedicated-global EOM
0255Y905SSD module-Servers-SSD-6400GB-NVMe PCIe-mixed read-write-EP600 series-2.5 inch(2.5 inch bracket)-V7 dedicated-global EOM
0255Y906SSD module-Servers-SSD-6400GB-NVMe PCIe-mixed read-write-EP600 series-2.5 inch(3.5 inch bracket)-V7 dedicated-global EOM
0255YBWESSD Module,Servers,M.2 SSD,NVMe PCIe,1920GB,80.0mm * 22.0mm * 3.58 mm(Non-hot-swappable),PJ1 series Current Field replaceable
0255YCUYSSD Module,Servers,M.2 SSD,NVMe PCIe,480GB,80.0mm * 22.0mm * 3.58 mm(Non-hot-swappable),PM9A3 series Current Field replaceable
0255YCULSSD Module,Servers,M.2 SSD,NVMe PCIe,960GB,80.0mm * 22.0mm * 3.58 mm(Non-hot-swappable),PJ1 series Current Field replaceable
P/NDescription / SpecificationStatus
02312FLQfunction module-2288H V5-BC1SPSCA11-INTEL VROC KEY,advanced edition,supports RAID 0/1/10/5 Current
02312FLRfunction module-2288H V5-BC1SPSCA12-INTEL VROC KEY,standard edition,supports RAID 0/1/10 Current
0231Y131function module-9560-16i 8G-CN2M956016I8G-9560-16i 8G other board card-12G SAS RAID card-8G cache-16*12Gb/s SAS PHY-2 slimline internal interface-PCIE 4.0 X8-Vendor ID 1000-Device ID 10E2-Subvendor ID 1000-Subdevice ID 4000 Current
0231Y735function module-9540-8i-CN2M95408I-PCIE 4.0 X8-Vendor ID 1000-Device ID 10E6-1-Subvendor ID 1000-Subdevice ID 40D5-12G SAS RAID-9540-8i-x8 PCIe 4.0-9540-8i SAS RAID Card,SAS3808,No CacheVault,12Gb/s SAS,6Gb/s SATA,PCIe(NVMe)-9540-8i Current
0231YDQMfunction module-G5500 V7-BC5M05RLAE-XC170-M-8i-(SAS3808iMR)-SAS/SATA RAID cable card-RAID0,1,10-12Gb/s-no Cache-supports sideband management-PCIE 4.0 X8-Vendor ID 1000-Device ID 10E6-1-Subvendor ID 1F24-Subdevice ID 3002 Current
0231YDQNfunction module-G5500 V7-BC5M08RLAD-XC470C-M-8i 4G-(SAS3908)-RAID cable card-RAID0,1,5,6,10,50,60-12Gb/s-4GB Cache-supports supercap & sideband management-PCIE 4.0 X8-Vendor ID 1000-Device ID 10E2-1-Subvendor ID 1F24-Subdevice ID 3000 Current
0256Y174RAID card module-2288H V7-9560-8i 4G-12G SAS RAID card-9560-8i-(SAS3908)-CVPM05-12Gb/s SAS-6Gb/s SATA-PCIe(NVMe)-4G CacheVault-PCIE 4.0 X8-Vendor ID 1000-Device ID 10E2-Subvendor ID 1000-Subdevice ID 4010 Current
0256Y179RAID card module-2288H V7-9560-16i 8G-12G SAS RAID card-9560-16i-(SAS3916)-CVPM05-12Gb/s SAS,6Gb/s SATA,PCIe(NVMe)-8G CacheVault-PCIE 4.0 X8-Vendor ID 1000-Device ID 10E2-Subvendor ID 1000-Subdevice ID 4000 Current
NAINTEL VROC SATA RAID 0/1/10/5 Current
0231Y129function module-9560-8i 4G-CN2M95608I4G-9560-8i 4G other board card-12G SAS RAID card-4G cache-8*12Gb/s SAS PHY-1 slimline internal interface-PCIE 4.0 X8-Vendor ID 1000-Device ID 10E2-Subvendor ID 1000-Subdevice ID 4010 EOM
0817Y002Super capacitor module,64mm*51mm*13.1mm,Wire mounting,split from 08170002,NA,7600uF,5h Current Field replaceable
0302Y201Manufactured Board-JDM,Public Module,BC55RLAD,XC470C-M-8i 4G-(SAS3908)-RAID Cable Card-RAID0,1,5,6,10,50,60-12Gb/s-4GB Cache,Capacitor and Management,PCIE 4.0 X8-Vendor ID 1000-Device ID 10E2-1-Subvendor ID 1F24-Subdevice ID 3000,1*1 Current Field replaceable
0302Y204Manufactured Board-JDM,Public Module,BC56RLAE,XC170-M-8i-(SAS3808iMR)-SAS/SATA RAID Cable Card-RAID0,1,10-12Gb/s-no Cache,Support Sideband Management,PCIE 4.0 X8-Vendor ID 1000-Device ID 10E6-1-Subvendor ID 1F24-Subdevice ID 3002,1*1 Current Field replaceable
0231Y651Function Module,9500-8i,CN2M95008I,PCIE 4.0 X8-Vendor ID 1000-Device ID 00E6-1-Subvendor ID 1000-Subdevice ID 4060-12G SAS RAID Card,x8 PCIe 4.0-9500-8i SAS RAID Card,SAS3808,No CacheVault,12Gb/s SAS,6Gb/s SATA,PCIe(NVMe)-9500-8i Current Field replaceable
P/NDescription / SpecificationStatus
0231Y803function module-Servers-CN2M01ITGBA1-XP210 Intel I350 2*GE+half-height half-length(incl. half-height & full-height brackets)standard network adapter-PCIE 2.0 X4-Vendor ID 8086-Device ID 1521-2 Current
0231Y804function module-Servers-CN2M01ITGC1-XP212 Intel I350 4*GE+half-height half-length(incl. half-height & full-height brackets)standard network adapter-PCIE 2.0 X4-Vendor ID 8086-Device ID 1521-4 Current
0231Y809function module-Servers-CN2M04ITGG1-XP330 Ethernet adapter-10Gb optical port(Intel X710)-dual-port-SFP+(optical module not included)-half-height half-length(incl. half-height & full-height brackets)-PCIe 3.0 x8 Current
0231Y812function module-Servers-CN2M03ITGH1-XP332 Ethernet adapter-10Gb optical port(Intel XL710)-quad-port-SFP+(optical module not included)-half-height half-length(incl. half-height & full-height brackets)-PCIe 3.0 x8 Current
0231Y822function module-Servers-BC5M02ETHK1-XP382 Ethernet adapter-25GE optical port(Mellanox CX5)-dual-port-SFP28(optical module not included)-half-height half-length-half-height bracket-PCIe 3.0 x8 Current
0231Y829function module-Servers-CN2M06ITGG1-XP330 Ethernet adapter-10Gb optical port(Intel X710)-dual-port-SFP+(incl. 2 optical modules)-half-height half-length(incl. half-height & full-height brackets)-PCIe 3.0 x8(domestic & overseas) Current
0231Y830function module-Servers-CN2M05ITGH1-XP332 Ethernet adapter-10Gb optical port(Intel XL710)-quad-port-SFP(incl. 4 optical modules)-half-height half-length(incl. half-height & full-height brackets)-PCIe 3.0 x8(domestic & overseas) Current
0257Y099PCIe-network adapter-2288H V6-E810XXVDA2G1P5-network adapter-25G optical port(E810XXVDA2G1P5 978333)-dual-port-SFP28(optical module not included)-PCIE 4.0 X8-8086-159b|0003-2-with driver package Current
0257Y101PCIe-network adapter-2288H V6-E810CQDA2-network adapter-100G optical port(E810CQDA2G2P5 99A454)-dual-port-QSFP28(optical module not included)-PCIE 4.0 X16-8086-1592|0002-2-with driver package Current
0257Y102PCIe-network adapter-2288H V6-MCX631102AN-ADAT-network adapter-25 GE-64bit-SFP28-2-PCIE 4.0 x8-15b3-101f-2-with driver package Current
0257Y109PCIe-network adapter-2288H V6-LPE31000-AP-Emulex -FC HBA card-16Gb/s(LPe31000)-single-port-SFP+(incl. 1 multimode optical modules)-PCIE 3.0 x8-Vendor ID 10DF-Device ID E300-1-Subvendor ID 10DF-Subdevice ID E311-with driver package Current
0257Y110PCIe-network adapter-2288H V6-LPe31002-AP-Emulex -FC HBA card-16Gb/s(LPe31002)-dual-port-SFP+(incl. 2 multimode optical modules)-PCIE 3.0 x8-Vendor ID 10DF-Device ID E300-2-Subvendor ID 10DF-Subdevice ID E310-with driver package Current
0257Y112PCIe-network adapter-2288H V6-LPe32002-AP-Emulex -FC HBA card-32Gb/s(LPe320PCIE 3.0 x8-Vendor ID 10DF-Device ID E300-2-Subvendor ID 10DF-Subdevice ID E30002)-dual-port-SFP+(incl. 2 multimode optical modules)--with driver package Current
0257Y114PCIe-network adapter-2288H V6-MCX653105A-HDAT-Infiniband MCX653105A-HDAT-200Gb/s-64bit-QSFP56-1port-PCIE 4.0 x16-Vendor ID 15b3-Device ID 101b-1-Subvendor ID 15b3-Subdevice ID 0007-with driver package Current
0257Y115PCIe-network adapter-2288H V6-BCM95719A1904AC-BCM95719A1904AC network adapter-GE-64bit-4*1000BASE-T-4-PCIE 2.0 x4-14e4-1657-4-with driver package Current
0257Y116PCIe-network adapter-2288H V6-X710T2L-10Gb/s-64bit-10GBASE-T-2 ports-PCIE 3.0 x8-8086-15ff-2-with driver package Current
0257Y122PCIe-network adapter-5885H V7-LPE35000-AP-Emulex -HBA Card LPE35000-AP-FC single-port-32Gb/s-PCIE 4.0 x8-Vendor ID 10DF-Device ID F400-1-with driver package Current
0257Y123PCIe-network adapter-5885H V7-LPE35002-AP-Emulex -HBA Card LPE35002-AP-FC dual-port-32Gb/s-PCIE 4.0 x8-Vendor ID 10DF-Device ID F400-2-with driver package Current
0257Y125PCIe-network adapter-5885H V7-QLE2772-CEM-BK-Qlogic-HBA Card QLE2772-CEM-BK-FC dual-port-32Gb/s-PCIE 4.0 x8-Vendor ID 1077-Device ID 2281-2-with driver package Current
0257Y150PCIe-network adapter-2288H V6-MCX623106AN-CDAT-network adapter-100Gb optical port(MCX623106AN-CDAT)-dual-port-QSFP56(optical module not included)-half-height half-length-PCIE 4.0 x16-15b3-101d-2-with driver package Current
0257Y225PCIe-GPU card-G5500 V7-BC2A800GPU83-NA080 PCIe compute accelerator card-80GB-PCIe 4.0 x16 Current
0257Y246PCIe-IB card-G8600 V7-MCX755106AS-HEAT-Infiniband MCX755106AS-HEAT-200Gb/s NDR200 IB,dual-port QSFP112-PCIE 5.0 x16-Vendor ID 15B3-Device ID 1021-2-Subvendor ID 15B3-Subdevice ID 0022(optical module not included) Current
0257Y302PCIe-network adapter-2288H V6-LPE36002-LPe36002-AP-FC HBA card-64Gb/s-dual-port-PCIE 4.0 x8-Vendor ID 10df-Device ID f400-2-Subvendor ID 10df-Subdevice ID f404-with driver package Current
0257Y361PCIe-GPU card-G5500 V7-BC3L20GPU02-NL02 PCIe compute accelerator card-48GB-PCIe 4.0 x16 Current
0257Y390PCIe-network adapter-2288H V7-MCX75310AAS-NEAT-IB card-Infiniband MCX75310AAS-NEAT-NDR/NDR200/HDR100/EDR IB single-port OSFP-400Gb/s-PCIE 5.0 x16-Vendor ID 15B3-Device ID 1021-1-Subvendor ID 15B3-Subdevice ID 0023-with driver package Current
0257Y391PCIe-network adapter-2288H V7-MCX75310AAS-HEAT-IB card-Infiniband MCX75310AAS-HEAT-200Gb/s NDR200 IB,single-port OSFP-PCIE 5.0 x16-Vendor ID 15B3-Device ID 1021-1-Subvendor ID 15B3-Subdevice ID 0029-with driver package Current
0257Y412PCIe-network adapter-G5500 V7-900-9D3B6-00SV-AA0-network adapter-200Gb/s-64bit-QSFP112-2 Ports-PCIE 5.0 x16-15B3-A2DC|C2D5-3-NVIDIA BlueField B3220 With Crypto-Single-Slot-32GB DDR5-FHHL(incl. NCSI cable) Current
0257Y476PCIe-network adapter-2288H V7-BCM957608-P2200GQF00-network adapter-200 Gigabit-64bit-QSFP56-2 ports-PCIE 5.0 x16-Vendor ID 14e4-Device ID 1760-2-Subvendor ID 14e4-Subdevice ID 9120-with driver package Current
0257Y478PCIe-GPU card-G5500 V7-ITEnflame S60-GPU card-Enflame S60 GPU-48GB Memory/672 GB/s Bandwidth/PCIE 5.0 x16-1E36-C035-1,300W/DualSlot Current
0257Y511PCIe-GPU card-G5500 V7-Metax C500-GPU card-Metax C500 GPU-64GB HBM2e/1.8 TB/s Bandwidth/PCIE 5.0 x16-9999-4001-1,350W/DualSlot-Chinese documentation-1PCS Cable-FHFL-1PCS Cable Current
0257Y520PCIe-network adapter-2288H V7-BCM957508-P2100G-network adapter-100Gb optical port-dual-port-QSFP28-half-height half-length-PCIE 4.0 x16-Vendor ID 14e4-Device ID 1750-2-Subvendor ID 14e4-Subdevice ID 2100 Current
0257Y549PCIe-GPU card-G5500 V7-WT-X201-GPU card-WT-X201-64GB HBM2e/1.8 TB/s Bandwidth/PCIE 5.0 x16-2020-7801-1,350W/DualSlot-Chinese documentation-No Cable-FHFL Current
0257Y551PCIe-network adapter-G5500 V7-BCM957608-P1400GDF00-network adapter-400 Gigabit-64bit-QSFP-DD-1 port-PCIE 5.0 x16-Vendor ID 14e4-Device ID 1760-1-Subvendor ID 14e4-Subdevice ID 9140 Current
0257Y563PCIe-GPU card-G5500 V7-Biren106C-GPU card-Bili 106C generic GPU PCIe-32GB HBM2e/819.2 GB/s Bandwidth/PCIE 4.0 x16-1EE0-001F-1/150W-full-height full-length-single-slot-Chinese documentation-No Cable Current
0257Y564PCIe-GPU card-G5500 V7-Metax N260-GPU card-Metax N260 GPU-64GB HBM2e/1.6 TB/s Bandwidth/PCIE 4.0 x16-9999-4083-1,225W/DualSlot-Chinese documentation-1PCS Cable-FHFL Current
0257Y600PCIe-GPU card-G5500 V7-NA01 PCIe GPU-GPU card-GPU-Data Center NA01 PCIe-PN:900-2G133-0020-000/24GB Memory/600GB/s Bandwidth/PCIE 4.0 x16-10DE-2236-1,150W/singleSlot/PassiveCooling-English documentation-No Cable Current
0257Y656PCIe-GPU card-G5500 V7-P800-GPU card-Kunlun core P800 PCIe Card-96GB/PCIE 4.0 x16-2057-3686-1,350W/DualSlot-Chinese documentation-No Cable-FHFL-GPU:Bridge Board = 4:1 Current
0257Y663PCIe-GPU card-G5500 V7-BC3X0588GPU80-NX0588A-PN:900-5G133-2240-000/48GB GDDR6 Memory/960GB/s Memory Bandwidth/PCIE 4.0 x16-10DE-22BA|2683-2/285W-English documentation-Dual slot-Passive Current
0257Y664PCIe-GPU card-G5500 V7-MTT S3000-32GB Memory/448 GB/s Bandwidth/PCIE 5.0 x16-1ED5-0222|02FF-2,250W/DualSlot-Chinese documentation-1PCS Cable-FHFL Current
0257Y686PCIe-GPU card-G5500 V7-BC3IGX2EGPU03-96GB HBM2e/2.45 TB/s Bandwidth/PCIE 4.0 x16-1DA3-1021-1,450W/DualSlot-English documentation-No Cable-Full Height Full Length,Passive cooling Current
0257Y818PCIe-GPU card-G5500 V7-BC3NRP0500GPU03-GPU card-NRP0500 72GB Blackwell-NRP0500 72GB Blackwell/FHFL/dual-slot/300W/PCIe 5.0x16-English documentation Current
0231Y984function module-Servers-BC5M13ETHE1-XP380 Ethernet adapter-25GE optical port(Mellanox CX-4 Lx)-dual-port-SFP28(optical module not included)-half-height half-length-half-height bracket-PCIe 3.0 x8 EOM
0257Y095PCIe-network adapter-2288H V6-MCX512A-ACAT-network adapter-25Gb optical port(MCX512A-ACAT)-dual-port-SFP28(optical module not included)-PCIE 3.0 x8-15b3-1017-2-Subvendor ID 15b3-Subdevice ID 0020-with driver package EOP
0257Y113PCIe-network adapter-2288H V6-MCX653105A-ECAT-Infiniband MCX653105A-ECAT-HDR100/EDR IB single-port-100Gb/s-PCIE 4.0 x16-Vendor ID 15b3-Device ID 101b-1|2-Subvendor ID 15b3-Subdevice ID 0006-with driver package EOM
0257Y144PCIe-GPU card-G5500 V7-BC3L4GPU02-NVIDIA-Tesla L4 PCIe compute accelerator card-24GB-PCIe 4.0 x16 EOP
0257Y146PCIe-GPU card-G5500 V7-BC3L40GPU02-NL04 PCIe compute accelerator card-48GB-PCIe 4.0 x16 EOP
0257Y147PCIe-GPU card-G5500 V7-BC3H800GPU02-NH080 PCIe compute accelerator card-80GB-PCIe 5.0 x16 EOP
0257Y148PCIe-GPU card-G5500 V7-BC3H100GPU02-NH010 PCIe compute accelerator card-80GB-PCIe 5.0 x16-overseas dedicated EOP
0257Y209PCIe-network adapter-2288H V6-MCX75310AAS-NEAT-MELLANOX MCX75310AAS-NEAT NDR/NDR200/HDR100/EDR IB card-400Gb/s-single-port-OSFP-PCIE 5.0 x16-Vendor ID 15B3-Device ID 1021-1-Subvendor ID 15B3-Subdevice ID 0023-(only supports IB mode) EOP
0257Y211PCIe-network adapter-2288H V6-MCX75310AAS-HEAT-IB card-Infiniband MCX75310AAS-HEAT-200Gb/s NDR200 IB,single-port OSFP-PCIE 5.0 x16-Vendor ID 15B3-Device ID 1021-1-Subvendor ID 15B3-Subdevice ID 0029-with driver package-(only supports IB mode) EOP
0257Y230PCIe-network adapter-2288H V6-MCX653106A-ECAT-other board card-Infiniband MCX653106A-ECAT-HDR100/EDR 100GbE IB dual-port-100Gb/s-PCIE 4.0 x16-Vendor ID 15b3-Device ID 101b-2-Subvendor ID 15b3-Subdevice ID 0008-with driver package EOP
0257Y278PCIe-GPU card-G5500 V7-BC3L40SGPU01-NVIDIA-Tesla L40S PCIe compute accelerator card-48GB-PCIe 4.0 x16 EOP
0257Y384PCIe-GPU card-G5500 V7-BC3L2GPU02-NLX2 PCIe compute accelerator card-24GB-PCIe 4.0 x16 EOM
3406Y008High Speed Transceiver,SFP28,850nm,25G,-8.4dBm,2.4dBm,-10.3dBm,LC,MM,0.1km,Original 34061254 split Current Field replaceable
3406Y006XFP|SFP+ Transceiver,SFP+,850nm,10Gb/s,-7.3dBm,-1dBm,-9.9dBm,LC,0.3km Current Field replaceable
3406Y011High Speed Transceiver,QSFP28,850nm,100G,-8.4dBm,2.4dBm,-10.3dBm,MPO,MM,0.1km,OM4 Original 34061089 split Current Field replaceable
3406Y009High Speed Transceiver,QSFP+,850nm,41.25Gbps,-7.6dBm,0.5dBm,-9.5dBm,MPO,0.15km,Original 34060662-002 split Current Field replaceable
3406Y007XFP|SFP+ Transceiver,SFP+,1310nm,10Gb/s,-8.2dBm,0.5dBm,-12.6dBm,LC,10km Current Field replaceable
0631Y027Network Card,100GE,64bit,QSFP56(without Optical Transceiver),2 Ports,PCIE 4.0 x16-15b3-101d-2,No Driver CD Current Field replaceable
0302Y437Manufactured Board,XP380,BC51ETHE3,Ethernet Adapter,25GE(Mellanox CX-4 Lx),Dual-Port,SFP28(without Optical Transceiver),PCIE 3.0 x8-Vendor ID 15b3-Device ID 1015-2-Subvendor ID 1f24-Subdevice ID 2005,1*2 Current Field replaceable
0257Y100PCIe-NIC Card,2288H V6,MCX515A-CCAT,Network Card,100Gb Optical Interface(MCX515A-CCAT),1-Port,QSFP28(without Optical Transceiver),PCIE 3.0 x16-15b3-1017-1,With driver pack Current Field replaceable
0302Y043Manufactured Board,Public Module,CN21ITGBA1,XP210 I350 2*GE PCIE Card,PCIE 2.0 X4-Vendor ID 8086-Device ID 1521-2-Subvendor ID 1f24-Subdevice ID 2000,1*2 Current Field replaceable
0302Y044Manufactured Board,Public Module,CN21ITGC1,XP212 I350 4*GE PCIE Card,PCIE 2.0 X4-Vendor ID 8086-Device ID 1521-4-Subvendor ID 1f24-Subdevice ID 2001,1*2 Current Field replaceable
0302Y046Manufactured Board,Public Module,CN21ITGG1,XP330 Ethernet Adapter,10Gb Optical Interface(Intel X710),2-Port,SFP+(without Optical Transceiver),PCIE 3.0 X8-Vendor ID 8086-Device ID 1572-2-Subvendor ID 1f24-Subdevice ID 2003,1*2 Current Field replaceable
0302Y047Manufactured Board,Public Module,CN21ITGH1,XP332 Ethernet Adapter,10Gb Optical Interface(Intel XL710),4-Port,SFP+(without Optical Transceiver),PCIE 3.0 X8-Vendor ID 8086-Device ID 1572-4-Subvendor ID 1f24-Subdevice ID 2004,1*2 Current Field replaceable
06310156Network Card,25 Gigabit,64bit,SFP28(without Optical Transceiver),2 Ports,PCIE 3.0 x8-15b3-1017-2-Subvendor ID 15b3-Subdevice ID 0020,No Driver CD,with 1pcs short bracket Current Field replaceable
0302Y049Manufactured Board,Public Module,BC51ETHK1,XP382 Ethernet Adapter,25GE(Mellanox CX-5 Lx),Dual-Port,SFP28(without Optical Transceiver),PCIE 3.0 x8-Vendor ID 15b3-Device ID 1017-2-Subvendor ID 1f24-Subdevice ID 2006,1*2 Current Field replaceable
0631Y040Network Card,25 GE,64bit,SFP28,2,PCIE 4.0 x8-15b3-101f-2,No Driver CD Current Field replaceable
06030393Other Cards,HBA Card LPe32002-AP,FC Double Ports-32Gb/s,PCIE 3.0 x8-Vendor ID 10DF-Device ID E300-2-Subvendor ID 10DF-Subdevice ID E300,English doc,1pcs short bracket,half width half length-Prohibition of separate shipment Current Field replaceable
0603Y018IB Card,Infiniband MCX653105A-HDAT,200Gb/s-64bit-QSFP56-1port,PCIE 4.0 x16-Vendor ID 15b3-Device ID 101b-1-Subvendor ID 15b3-Subdevice ID 0007,Chinese and English doc Current Field replaceable
0632Y027Video Card,GPU-Data Center A800 PCIe,PN:900-21001-0030-100/80GB HBM2e Memory/ 1.9TB/s Bandwidth/ PCIE 4.0 x16-10DE-20F5-1,300W/ DualSlot/PassiveCooling,NULL,1PCS Cable Current Field replaceable
3406Y004Active Optical Cable Assembly,200GbE, QSFP56,IB HDR, 200Gb/s, LSZH, black pulltab,0.01km Current Field replaceable
0302Y190Manufactured Board,G5500 V7,BC15PRUY,Front PCIe Riser Card(2*X16 PCIe 5.0),1*2 Current Field replaceable
0632Y074GPU Card,NVIDIA L20 GPU Accelerator,PN:900-2G133-00A0-000 / 48GB GDDR6 Memory / 864GB/s Memory Bandwidth /PCIE 4.0 x16-10DE-26BA-1 /350W,No NVLink,English doc,Dual slot,Passive Current Field replaceable
0632Y021GPU Card,2-Slot NVLink Bridge for NVIDIA GPU Pcie Card,PN:900-53651-0000-000,English doc Current Field replaceable
0632Y075GPU Card,NVIDIA L2 GPU Accelerator,PN:900-2G193-0030-000/24GB GDDR6 Memory/ 300GB/s peak Memory Bandwidth/ PCIE 4.0 x16-10DE-27B6-1,72W/ HHHL, single-slot/Passive cooling,English doc,No Cable Current Field replaceable
0632Y036Video Card,NVIDIA L4 GPU Accelerator,PN:900-2G193-0000-000/24GB GDDR6 Memory/ 300GB/s peak Memory Bandwidth/ PCIE 4.0 x16-10DE-27B8-1,72W/ HHHL, single-slot/Passive cooling,English doc,No Cable Current Field replaceable
0632Y035Video Card,NVIDIA L40 GPU Accelerator,PN:900-2G133-0010-000/48GB GDDR6 Memory/ 864GB/s peak Memory Bandwidth/ PCIE 4.0 x16-10DE-26B5-1,300W/ FHFL, dual-slot/Passive cooling,English doc,No Cable Current Field replaceable
0302Y185Manufactured Board,G5500 V7,BC15RSWA,PCIe Switch Board(8*X16 PCIe 5.0),1*1 Current Field replaceable
0302Y186Manufactured Board,G5500 V7,BC15RSWB,PCIe Switch Board(9*X16 PCIe 5.0),Support DPU,1*1 Current Field replaceable
3406Y005Active Optical Cable Assembly,200GbE, QSFP56,IB HDR, 200Gb/s, LSZH, black pulltab,0.02km Current Engineer replace
3406Y003Active Optical Cable Assembly,200GbE, QSFP56,IB HDR, 200Gb/s, LSZH, black pulltab,0.005km Current Field replaceable
3406Y033High Speed Transceiver,SFP28,850nm,25G,-8.4dBm,2.4dBm,-10.3dBm,LC,MM,0.1km,sont split Current Field replaceable
3406Y023High Speed Transceiver,QSFP56,850nm,200Gbps,-5.9dBm,4dBm,-4.4dBm,MPO12/UPC,MM,0.1km,8636 Current Field replaceable
3406Y012High Speed Transceiver,OSFP,850nm,400Gbps,-4.6dBm,4dBm,-4.4dBm,MPO-12/APC,MM,0.05km,OM4 Dedicated to IB NDR HCA Current Engineer replace
0302Y283Manufactured Board,G5500 V7,BC15PRUAD,Back PCIe Riser Card(1*X8 PCIe 4.0),1*4 Current Field replaceable
0632Y076GPU Card,Enflame S60 GPU,48GB Memory/672 GB/s Bandwidth/ PCIE 5.0 x16-1E36-C035-1,300W/DualSlot,Chinese doc,No Cable,FHFL Current Field replaceable
0632Y043Video Card,NVIDIA H100 PCIe GPU,PN:900-21010-0000-000/80GB HBM2e Memory/ 2TB/s Memory Bandwidth/ PCIE 5.0 x16-10DE-2331-1, 350W/ FHFL, dual-slot/Passive cooling,NO Cable,English doc,With NVAIE Current Field replaceable
0632Y086GPU Card,Iluvatar Corex TianGai 150 Accelerate PCIe Card,64GB HBM2e/ PCIE 4.0 x16-Vendor ID 1000|1E3E-Device ID 0003|C010-3,350W/DualSlot,Chinese doc,No Cable,FHFL Current Field replaceable
0632Y078GPU Card,MTT S3000,32GB Memory/448 GB/s Bandwidth/ PCIE 5.0 x16-1ED5-0222|02FF-2,250W/DualSlot,Chinese doc,1PCS Cable,FHFL Current Field replaceable
0632Y091GPU Card,Metax N260GPU,64GB HBM2e/1.6 TB/s Bandwidth/ PCIE 4.0 x16-9999-4083-1,225W/DualSlot,Chinese doc,No Cable,FHFL Current Field replaceable
0632Y083GPU Card,Metax C500 GPU,64GB HBM2e/1.8 TB/s Bandwidth/ PCIE 5.0 x16-9999-4001-1,350W/DualSlot,Chinese doc,No Cable,FHFL Current Field replaceable
0632Y093GPU Card,Biren106C GPGPU PCIe Card,32GB HBM2e/1.8 TB/s Bandwidth / PCIE 4.0 x16-1EE0-001F-1,150W/FHFL/Singleslot,Chinese doc,No Cable Current Field replaceable
0632Y060Video Card,NVIDIA L40S GPU Accelerator,PN:900-2G133-0080-000 / 48GB GDDR6 Memory / 864GB/s Memory Bandwidth /PCIE 4.0 x16-10DE-26B9-1 /350W,No NVLink,English doc,Dual slot,Passive Current Field replaceable
0257Y106PCIe-NIC Card,2288H V6,MCX631432AN-ADAB,MCX631432AN-ADAB Ethernet Adapter,25GE(Mellanox CX6),Dual-Port,SFP28,PCIE 4.0 x8-15b3-101f-2,With driver pack-OCP Current Field replaceable
0257Y439PCIe-NIC Card,G5500 V7,MCX623430MS-CDAB,Ethernet Adapter,100Gb Optical Interface(MCX623430MS-CDAB),2-Ports,QSFP28(without Optical Transceiver),PCIe 4.0 x16-Vendor ID 15b3-Device ID 101d-2-Subvendor ID 15b3-Subdevice ID 0114 Current Field replaceable
0603Y037Other Cards,HBA Card LPe36002-AP,FC dual Ports-64Gb/s,PCIE 4.0 x8-Vendor ID 10df-Device ID f400-2-Subvendor ID 10df-Subdevice ID f404,Chinese and English doc,half width half length Current Field replaceable
P/NDescription / SpecificationStatus
0257Y106PCIe-network adapter-2288H V6-MCX631432AN-ADAB-MCX631432AN-ADAB Ethernet adapter-25GE(Mellanox CX6)-dual-port-SFP28-PCIE 4.0 x8-15b3-101f-2-with driver package-OCP Current
0257Y107PCIe-network adapter-2288H V6-E810XXVDA2OCP3G-Ethernet adapter-25GE(Intel E810)-dual-port-SFP28-PCIE 4.0 x8-Vendor ID 8086-Device ID 159b-2-Subvendor ID 8086-Subdevice ID 0005-with driver package-OCP Current
0302Y054manufactured board-JDM-Public Module-BC53ETHF-XC310 GE350-T2 OCP3.0 Ethernet adapter-2*GE(I350)-dual-port-RJ45,PCIE 2.1 x4-Vendor ID 8086-Device ID 1521-2-Subvendor ID 1f24-Subdevice ID 200b-1*4 Current
0302Y055manufactured board-JDM-Public Module-BC53ETHB1-XC382 OCP3.0 Ethernet adapter-25GE(CX5)-dual-port-SFP28(optical module not included)-PCIE 3.0 X8-Vendor ID 15b3-Device ID 1017-2-Subvendor ID 1f24-Subdevice ID 200c-1*4 Current
0302Y237manufactured board-JDM-Public Module-BC53ETHH-XC331 OCP3.0 Ethernet adapter-10GE(BCM57416)-dual-port-RJ45-PCIE 3.0 X8-Vendor ID 14e4-Device ID 16d8-2-Subvendor ID 1f24-Subdevice ID 2010-1*3 Current
0302Y238manufactured board-JDM-Public Module-BC55ETHA-XC385 OCP3.0 Ethernet adapter-25GE(CX6-Lx)-dual-port-SFP28(optical module not included)-PCIE 4.0 X8-Vendor ID 15b3-Device ID 101f-2-Subvendor ID 1f24-Subdevice ID 2011-1*4 Current
0302Y434manufactured board-JDM-Public Module-BC53ETHI-XC386 OCP3.0 Ethernet adapter-25GE(BCM57414)-dual-port-SFP28(optical module not included)-PCIE 3.0 X8-Vendor ID 14e4-Device ID 16d7-2-Subvendor ID 1f24-Subdevice ID 2013-1*4 Current
0302Y435manufactured board-JDM-Public Module-BC53ETHJ-XC333 OCP3.0 Ethernet adapter-10GE(BCM57412)-dual-port-SFP+(optical module not included)-PCIE 3.0 X8-Vendor ID 14e4-Device ID 16d6-2-Subvendor ID 1f24-Subdevice ID 2014-1*4 Current
0302Y085manufactured board-JDM-Public Module-BC53ETHG-XC383 OCP3.0 Ethernet adapter-10GE(CX-4 Lx)-dual-port-SFP+(optical module not included)-PCIE 3.0 X8-Vendor ID 15b3-Device ID 1015-2-Subvendor ID 1f24-Subdevice ID 200d-1*4 EOM
P/NDescription / SpecificationStatus
02313ADYfunction module-TS200-2280-BC11TPMC02-TPM2.0 card(SPI)-China dedicated Current
02313APLfunction module-TS200-2280-BC11TPMA02-TPM2.0 card(SPI)-international dedicated Current
02313KFCfunction module-2488H V6-BC11TPMA07-TCM card(SPI) Current
03028HYWManufactured Board,TaiShan 200 (Model 2280),BC11TPMD,TPM2.0 Card(SPI), China Dedicated,5*4 Current Engineer replace
03024QEJManufactured Board,2288H V5,BC11TPMB,TCM Card(SPI),5*4 Current Engineer replace
03024QEHManufactured Board,2288H V5,BC11TPMA,TPM2.0 Card(SPI), Overseas Dedicated,5*4 Current Engineer replace
P/NDescription / SpecificationStatus
0302012406manufactured board-2288H V7-BC15NHBB-24*NVMe(incl. 8*SAS/SATA)pass-through drive backplane-1*2 NONE
0302Y242manufactured board-G5500 V7-BC15THCL-24*3.5 SAS/SATA(incl. 8*NVME)Expander drive backplane-1*1 NONE
0302Y594manufactured board-G5500 V7-BC15HBBBA-12*3.5 inch SAS/SATA pass-through(incl. 4*NVMe)drive backplane-1*2 NONE
P/NDescription / SpecificationStatus
02314FNUfunction module-PAC2600S12-B2-server platinum 2600W 2.0 versionAC power supply-kunlun dedicated(model PAC2600S12-B2,interface IEC 320-C20) Current
0231Y019server platinum 2000W 2.0 versionAC power supply(model PAC2000S12-B1,interface IEC 320-C14) Current
0231Y0233000W titanium AC power supply(model PAC3000S12-T1,interface IEC 320-C20) Current
0231Y025server titanium 2000W AC power supply module(model PAC2000S12-T1,interface IEC 320-C14) Current
0231Y0342000W AC power supply module(model PAC2000S12-BE,interface IEC 320-C14) Current
0231YEKUprimary power supply-XA3000-server titanium 3000W AC power supply(model XA3000,interface IEC 320-C20) Current
0302Y184Manufactured Board,G5500 V7,BC15PBPD,12V Power BackPlane board,Power interface numbering reversed from chassis silk-screen; software adaptation required, caution when borrowing,2*1 Current Field replaceable
P/NDescription / SpecificationStatus
0255YBWESSD module-Servers-M.2 SSD-NVMe PCIe-1920GB-80.0mm * 22.0mm * 3.58 mm(non-hot-swappable)-PJ1 series Current
0255YCULSSD module-Servers-M.2 SSD-NVMe PCIe-960GB-80.0mm * 22.0mm * 3.58 mm(non-hot-swappable)-PJ1 series Current
0255YCUYSSD module-Servers-M.2 SSD-NVMe PCIe-480GB-80.0mm * 22.0mm * 3.58 mm(non-hot-swappable)-PM9A3 series Current
0255YEUUSSD module-Servers-M.2 SSD-NVMe PCIe-1920GB-80.0mm * 22.0mm * 3.58 mm(non-hot-swappable)-PJ1 series Current
0255YFDHSSD module-Servers-M.2 SSD-NVMe PCIe-480GB-80.0mm * 22.0mm * 3.58 mm(non-hot-swappable)-PM9A3 series Current
02313AREfunction module-Public Module-M.2 SSD-SATA 6Gb/s-240GB-80.0mm * 22.0mm * 3.58 mm(non-hot-swappable) EOM
02313ARJfunction module-Public Module-M.2 SSD-SATA 6Gb/s-480GB-80.0mm * 22.0mm * 3.58 mm(non-hot-swappable) EOM
90010339Liquid Manufactory Auxiliaries,Thermal Grease,X-23-7868-2D,Thermal Conductivity 3.6W/mK / 6.0W/mK,2g,Gap filling thermal conductive for customer use,1ml Current Engineer replace
03025VYYManufactured Board,TaiShan 2280 V2,BC82LCIA,Left Customer Interface,4*2 Current Engineer replace
43020236SAS Expander,NA,VROC KEY,RAID0/1/10,Standard,100mW,0.125MB/s Current Engineer replace
43020237SAS Expander,NA,VROC KEY,RAID 0/1/10/5,Premium,100mW,0.125MB/s Current Engineer replace
03028PTJManufactured Board,TS200-2280,BC82RCIC,Right Customer Interface Board,5*2 Current Engineer replace
0231Y675Function Module,1288H V7 (Model 1288),BC2M6ERISE,Unpacking Inspection Module Current Engineer replace
0258Y069IO Extended Module-PCIE,G5500 V6,BC1M01PRUAE,1*8X SLOT(PCIE4.0),RAID Card riser,Suitable for G5500 3.5-inch integrated equipment Current Engineer replace
0258Y068IO Extended Module-PCIE,G5500 V6,BC1M01PRUW,1*16X SLOT,CPU straight out IO Extended Module Current Engineer replace
0258Y074IO Extended Module-PCIE,G5500 V6,BC1M01CNTE,1*16X Single ROOT switching module Current Engineer replace
0258Y070IO Extended Module-Hard Disk,G5500 V6,BC1M05MSMA,Built in M.2 riser card, Supporting SATA/PCIE media,Supports two M.2 media slots Current Engineer replace
0302Y183Manufactured Board,G5500 V7,BC15MBSF,Server Motherboard,1*1 Current Field replaceable
0302Y636Manufactured Board,G5500 V7,BC15MBSM,Customization Server Motherboard,1*1 Current Field replaceable
0302Y187Manufactured Board,G5500 V7,BC15BIOA,Back IO Board(8*X16 PCIe5.0+1*X8 PCIe 4.0),1*1 Current Field replaceable
0258Y255IO Extended Module-PCIE,G5500 V6,BC1M02PRUAE,1*8X SLOT(PCIE4.0),RAID Card riser,Suitable for G5500 2.5-inch integrated equipment Current Engineer replace
P/NDescription / SpecificationStatus
04052259Power cord,China AC Power 250V2.5A,2.0m,PISM,227IEC53-0.75^2(3C),C5SF,250V,2.5A,Black Current Engineer replace
04051080Power cord,South Africa AC Power 250V10A,3m,PMAM,H05VV-F-1.0mm^2(3C),C13SF,250V,10A,Black Current Engineer replace
04041119Power Cable,Switzerland AC Power Cable 250V10A,3.0m,PJSM ,H05VV-F-1.0mm^2(3C),C13SF,Black Current Engineer replace
04050517Power Cable,China AC Power Cable 250V10A,2.0m,PISM,227IEC53(RVV)1.0mm^2(3C),C13SF,Black Current Engineer replace
0415G005Power cord,China AC Power 250V10A,2.0m,C14SM,227IEC53-1.0^2(3C),C13SF,PDU Cable Current Engineer replace
0405G02CPower Cords Cable,China AC Power 250V10A,0.8m,C14SM,227IEC53 1.0^2(3C),C13SF,PDU Cable Current Engineer replace
0405G02DPower Cords Cable,Japan AC Power 250V12A,1.8m,C14SM,HVCTF 1.25^2(3C),C13SF,PDU Cable Current Engineer replace
04050955Power Cords Cable,China AC Power,250V10A,1.5m,PISM,227IEC53(RVV)1.0mm^2(3C),C13SF,250V,10A,Black Current Engineer replace
0405G02FPower Cords Cable,Australia AC Power 250V10A,1.8m,C14SM,H05VV-F-1.0^2(3C),C13SF,PDU Cable Current Engineer replace
04041117Power Cable,Britain AC Power Cable 250V10A,3.0m,PGAM ,H05VV-F-1.0mm^2(3C),C13AF-L,Black Current Engineer replace
0405G02HPower Cords Cable,Korea AC Power 250V10A,1.8m,C14SM,H05VV-F-1.0^2(3C),C13SF,PDU Cable Current Engineer replace
0405G02KPower Cords Cable,Denmark AC Power 250V10A,3m,PKSM,H05VV-F-3*1.0^2(3C),C13SF,Black Current Engineer replace
0405G028Power Cords Cable,Korea AC Power 250V10A,3m,PFSM,H05VV-F 3*1.0^2(3C),C13SF,Black Current Engineer replace
04050588Power cord,China AC Power Cable250V10A,1.5 m,C14SM,(227IEC53(RVV)1.0mm^2(3C)),C13SF,250V,10A,White,PDU Cable Current Engineer replace
0405G029Power Cords Cable,North America AC Power 250V10A,1.8m,C14SM,SJT 18AWG(3C),C13SF,PDU Cable Current Engineer replace
04050784Power Cords Cable,China AC Power Cable,250V16A,2m,C14SM,227IEC53-1.0^2(3C),C13SF,Yellow Current Engineer replace
04051035Power cord,India AC Power 250V6A,3m,PM-IIAM,IS 694-1.0^2(3C),C13 SF,250V,6A,Black Current Engineer replace
04050188Power Cords Cable,China AC Power 250V10A,1.5m,C14SM,227IEC53(RVV)1.0mm^2(3C),C13SF,PDU Cable Current Engineer replace
04020728Power Cable,America AC Power Cable,125V10A,3.0m,PBSM,18SJT(3C),C13SF,Black Current Engineer replace
04042698Power Cords Cable,China AC Power 250V10A,15.0m,PISM,227IEC53-1.0^2(3C),C13SF,Black Current Engineer replace
0415Y021Power Cable,0.25m,H2X6(3.0),8*18UL1569B+8*22UL1569B,2*H2X4(4.2),PCIe12-2*PCIe 8 Current Engineer replace
04042697Power Cords Cable,China AC Power 250V10A,10.0m,PISM,227IEC53-1.0^2(3C),C13SF,Black Current Engineer replace
04042699Power Cords Cable,China AC Power 250V10A,20.0m,PISM,227IEC53-1.0^2(3C),C13SF,Black Current Engineer replace
04041120Power Cable,Italy AC Power Cable 250V10A,3.0m,PLSM,H05VV-F-1.0mm^2(3C),C13SF,Black Current Engineer replace
04047785Power Cords Cable,Argentina AC Power 250V10A,3.0m,PISM,H05VV-F-1.0mm^2(3C),C13SF,Black Current Engineer replace
04052137Power cord,Taiwan AC 125V11A,3.0m,PBSM,HVCTF 3*1.25mm2,C13SF,125V,11A,Black,BSMI Current Engineer replace
04040888Power Cords Cable,Australia AC Power Cable,250V 10A,3.0m,PISM,H05VV-F-1.0mm^2(3C),C13SF,Black Current Engineer replace
04040889Power cord,BS546 250V10A,3.0m,PM-IAM,H05VV-F-1.5mm^2(3C),C13SF,250V,10A,Black Current Engineer replace
0405G019Power Cords Cable,Europe AC 250V10A,1.8m,C14SM,H05VV-F- 3*1.00^2,C13SF,PDU Cable Current Engineer replace
04050373Power cord,China AC Power Cable250V10A,1.0m,C14SM,(227IEC53(RVV)-1.0mm^2(3C)),C13SF,Black,PDU Cable Current Engineer replace
04041056Power cord,Europe AC Power Cable,250V10A,3.0m,PFSM,(H05VVF 1.0^2(3C)),C13SF,250V,10A,BLack Current Engineer replace
04050139Power Cords Cable,China AC Power Cable,250V10A,3m,PISM,227IEC53-1.0^2(3C),C13SF,Black Current Engineer replace
04150258Power Cable,Brazil AC Power Cable 250V10A,3.0m,PNSM ,H05VV-F-1.0mm^2(3C),C13SF,Black Current Engineer replace
04040887Power Cable,Japan AC Power Cable 125V12A,3.0m,PBSM,HVCTF-1.25mm^2(3C),C13SF,Black Current Engineer replace
14130923Optical Cable Parts,MPO/PC,MPO/PC,MULTI-MODE,15m,8 CORES,0m/0m,GJFH-8A1A.2(OM3),3.5MM,LSZH,60mm MPO,Bending insensitive Current Engineer replace
04050847Power cord,China AC Power Cable,250V10A,6.0m,C14SM,(227IEC53-1.0^2(3C)),C13SF,250V,10A,Black,PDU Cable Current Engineer replace
04051858Power cord,China AC Power Cable 250V10A,3.0m,PISM,227IEC53-1.0^2(3C),C13SF,250V,10A,Yellow Current Engineer replace
04041104Power Cords Cable,China AC Power 250V10A,3.0m,PISM,227IEC53-1.0^2(3C),C13SF,Black Current Engineer replace
04050846Power cord,China AC Power Cable,250V10A,3.0m,C14SM,(227IEC53-1.0^2(3C)),C13SF,250V,10A,Black,PDU Cable Current Engineer replace
04050206Power Cable,China AC Power Cable 250V10A,1.0m,PISM,227IEC53(RVV)1.0mm^2(3C),C13SF,Black Current Engineer replace
04040890Power Cable,Britain AC Power Cable 250V10A,3.0m,PGAM ,H05VV-F-1.0mm^2(3C),C13SF,Black Current Engineer replace
04051403High Speed Cable,100G EDR QSFP28 Passive High Speed Cable,1m,QSFP28,CC8P0.4B(S),QSFP28,IB-Mellanox,LSZH Current Engineer replace
14270054BTB Connector module,74,UBC 8X curved,250mm,0.16mm,10mm,3200MB/s,1.57mm,Wire mounting,Y Current Engineer replace
04051404High Speed Cable,100G EDR QSFP28 Passive High Speed Cable,3m,QSFP28,CC8P0.4B(S),QSFP28,IB-Mellanox,LSZH Current Engineer replace
0405Y011High Speed Cable,25G SFP28 Passive High Speed Cable,3m,SFP28,CC2P0.254B(S),SFP28 Current Engineer replace
0405Y017High Speed Cable,HS Cable Slimline-2*mini SAS HD,0.8m&0.7m,Slimline X8 STR,2*((31AWG*1Pair+31AWG*2Drain)*8+31AWG*1Pair*4),2*Internal mini SAS HD R/A,Slimline-2*mini SAS HD Current Engineer replace
04051074Power cord,India AC Power 250V 16A,3m,PM-IIIAM,IS 694-1.5mm^2(3C),C19SF,250V,16A,Black Current Engineer replace
0405Y010High Speed Cable,25G SFP28 Passive High Speed Cable,1m,SFP28,CC2P0.254B(S),SFP28 Current Engineer replace
04050422Power Cords Cable,China /Europe/America/Korea Multiple Certificate AC Power 250V16A,3.0m,C20SM,H05VV-F-1.5mm^2(3C) +14SJT3(3C),C19SF,PDU Cable Current Engineer replace
04051079Power cord,South Africa AC Power 250V16A,3m,PMAM,H05VV-F-1.5mm^2(3C),C19SF,250V,16A,Black Current Engineer replace
04052442High Speed Cable,200G HDR QSFP56 Passive Copper cable,1m,QSFP56,QSFP56,IB-Mellanox,LSZH Current Engineer replace
0405Y009High Speed Cable,10G Passive SFP+ Cable,5m,(SFP+20M),(CC2P0.4B),(SFP+20M),LSFRZH For Indoor,ETH 10GbE,Y Current Engineer replace
0405Y008High Speed Cable,10G Passive SFP+ Cable,1m,(SFP+20M),(CC2P0.254B),(SFP+20M),LSFRZH For Indoor,ETH 10GbE,LSZH Current Engineer replace
0405Y128Power cord,Japan AC Power 250V15A,3.0m,NEMA5-15PSM,HVCTF-2.0mm^2(3C)black,C19SF,125V,15A Current Engineer replace
0405Y007High Speed Cable,10G SFP+ High Speed Cable,3m,SFP+20M,CC2P0.254B(S),SFP+20M,LSFRZH For Indoor,ETH 10GbE,LSZH Current Engineer replace
04043396Power Cords Cable,China AC Power 250V16A,3.0m,PIAM,227IEC53-2.5^2(3C),C19SF,Black Current Engineer replace
0415Y642Power Cable,250V-16A 3m,2.5mm^2(3C),black,C21,2.5mm^2(3C),C20 Current Engineer replace
04045184Power Cords Cable,Australia AC Power 250V16A,3.0m,PISM,H05VVF-2.5^2(3C),C19SF,Black Current Engineer replace
04051418Power cord,China AC Power 250V16A,30.0m,PIAM,227IEC53-2.5^2(3C),C19SF,250V,16A,Black Current Engineer replace
04052139Power cord,Taiwan AC 125V15A,3.0m,PBSM,VCTFK3*2.0mm2(3C),C19SF,125V,15A,Black,BSMI Current Engineer replace
04050189Power Cords Cable,China AC Power 250V 16A,1.0m,C20SM,227IEC53x1.5^2(3C),C19SF,PDU Cable Current Engineer replace
04044598Power Cords Cable,Europe AC Power 250V16A,3.0m,PFAM,H05VVF-1.5^2(3C),C19SF,Black Current Engineer replace
04044597Power cord,BS546 250V16A,3.0m,PM-IAM,H05VV-F-1.5mm^2(3C),C19SF,250V,16A,Black Current Engineer replace
04050850Power Cords Cable,Britain AC Power Cable,250V13A,3.0m,PG AM,H05VV-F-1.5mm^2(3C),C19 SF,Black Current Engineer replace
04050856Power Cords Cable,Australia AC Power 250V16A,3.0m,C20SM,H05VV-F-1.5^2(3C),C19SF,PDU Power Cord Current Engineer replace
04150259Power Cords Cable,Brazil AC Power 250V16A,3.0m,PN-ISM ,H05VVF-1.5^2(3C),C19SF,Black Current Engineer replace
04050855Power Cords Cable,Japan AC Power 250V15A,3.0m,C20SM,VCTF-2.0^2(3C),C19SF,PDU Power Cord Current Engineer replace
04044603Power Cords Cable,North America AC Power 125V20A,3.0m,NEMA5-20PAM,12SJT(3C),C19SF,Black Current Engineer replace
04080980Monitor&Alarm Cable,Signal cable,0.2m,H2X9(2.0),14*28UL1685B/14*28UL1685B(S),H2X9(2.0) Current Engineer replace
04051322Power cord,Switzerland AC Power Cable,3m,PJ-II SM,H05VV-F-1.5mm^2(3C),C19SF,250V,16A Current Engineer replace
0415Y075Power Cable,0.20m,Black,H2X6(3.0),8*18UL1569B,H2X4(4.2),PCIE 12Pin-PCIE 8Pin Current Engineer replace
0415Y074Power Cable,0.20m,Black,H2X6(3.0),8*18UL1569B,H2X4(4.2),PCIE 12Pin-CPU 8Pin Current Engineer replace
0405Y058High Speed Cable,PCIe 8i HS Cable,0.16m,LP Slimline X8 R/A,24*(1P*31AWG+2*Drain),LP Slimline X8 STR Current Engineer replace
1427Y036BTB Connector module,184pin-74pin,UBCDD 16X vertical plug,UBC 8X right-angle plug,450mm,0.16mm,10mm,32000MB/s,1.57mm,Wire mounting,Y Current Engineer replace
0415Y065Power Cable,0.65m,black,80A STR easy connector,20*18UL2651B,80A R/A easy connector No Pull,Parallel Cable Current Engineer replace
0405Y081IT Equipment Cable,Signal Cable,0.45m,(H2X25(1.0)),(4*(1P*30AWG+1*Drain)+5*(1P*30AWG)+3*30AWG Shield+22*UL1571 30AWG),(H2X25(1.0)) Current Engineer replace
0415Y046Power Cable,0.7m,Black,H2X7(3.0),2*18UL2651(8C)B(Flat),H2X7(3.0) Current Engineer replace
0408Y003Monitor&Alarm Cable,Signal cable,0.30m,H2X8(2.0),10*28UL1685B+3*28UL1569B+2*28UL1685B(S),H2X8(2.0),Front HDD board signal cable-2/4pin sheild Current Engineer replace
0415Y155Power Cable,0.22m,Black,H2X6(3.0)+1X4(2.0),12*16UL1569B+4*28UL1685B,H2X6(3.0)+1X4(2.0),H++_12P+4S Cable Current Engineer replace
0415Y036Power Cable,0.70m,black,80A STR easy connector,20*18UL2651B,80A R/A easy connector,No Pull,Parallel Cable Current Engineer replace
14270058BTB Connector module,184pin-74pin*2,UBCDD 16X vertical plug,UBC 8X right-angle plug*2,0.6&0.65m,0.16mm,10mm,32000MB/s,1.57mm,Wire mounting,Y Current Engineer replace
0415Y154Power Cable,0.32m,black,80A STR easy connector,20*18UL2651B,80A R/A easy connector,Parallel Cable Current Engineer replace
0405Y012High Speed Cable,25G SFP28 Passive High Speed Cable,5m,SFP28,CC2P0.4B(S),SFP28 Current Engineer replace
1427Y003BTB Connector module,184pin-74pin*2,UBCDD 16X right-angle plug,UBC 8X right-angle plug*2,450mm,0.16mm,10mm,32000MB/s,1.57mm,Wire mounting,Y Current Engineer replace
0408Y021Monitor&Alarm Cable,0.2m,H3(1.25),3*UL1685 28AWG,2*T110A+2*T0.25^2BL Current Engineer replace
0415Y615Power Cable,0.22m,Black,H2X6(3.0)+1X4(2.0),12*16UL1569B+4*28UL1685B,H2X6(3.0)+1X4(2.0),H++_12P+4S Cable Current Engineer replace
0405Y040High Speed Cable,HS Cable Slimline-2*mini SAS HD,1.1m&1.0m,Slimline X8 STR,2*((31AWG*1Pair+31AWG*2Drain)*8+31AWG*1Pair*4),2*Internal mini SAS HD R/A,Slimline-2*mini SAS HD Current Engineer replace
P/NDescription / SpecificationStatus
0231YADAFunction Module,G5500 V6,BC1M16FAN,Two 8080+ Fan module Current Field replaceable
0231YADBFunction Module,G5500 V6,BC1M17FAN,Single 8080+ Fan module(With false fan) Current Field replaceable
0231YERUFunction Module,G5500 V6,BC1M16FAN,Two 8080++ Fan module Current Field replaceable

Operating System Compatibility

Operating SystemVersion / KernelRelease
Citrix Hypervisor 8.24.19.0+1Citrix Hypervisor 8.2 LTSR
Debian 12.06.1.0-9-amd64Debian 12.0 for Intel EM64T
FusionOS 235.10.0-136.23.0.99.u37.fos23.x86_64FusionOS 23
KunLunOS 235.10.0-136.89.0.170.u137.klos23.x86_64KunLunOS 23
RHEL 10.06.12.0-55.9.1.el10_0.x86_64Red Hat Enterprise Linux 10 Server for Intel EM64T
RHEL 10.16.12.0-124.8.1.el10_1.x86_64Red Hat Enterprise Linux 10 Update 1 Server for Intel EM64T
RHEL 10.26.12.0-211.7.3.el10_2.x86_64Red Hat Enterprise Linux 10 Update 2 Server for Intel EM64T
RHEL 8.104.18.0-553.el8_10.x86_64Red Hat Enterprise Linux 8 Update 10 Server for Intel EM64T
RHEL 8.64.18.0-372.9.1.el8.x86_64Red Hat Enterprise Linux 8 Update 6 Server for Intel EM64T
RHEL 8.74.18.0-425.3.1.el8.x86_64Red Hat Enterprise Linux 8 Update 7 Server for Intel EM64T
RHEL 8.84.18.0-477.10.1.el8_8.x86_64Red Hat Enterprise Linux 8 Update 8 Server for Intel EM64T
RHEL 8.94.18.0-513.5.1.el8_9.x86_64Red Hat Enterprise Linux 8 Update 9 Server for Intel EM64T
RHEL 9.05.14.0-70.13.1.el9_0.x86_64Red Hat Enterprise Linux 9 Server for Intel EM64T
RHEL 9.15.14.0-162.6.1.el9_1.x86_64Red Hat Enterprise Linux 9 Update 1 Server for Intel EM64T
RHEL 9.25.14.0-284.11.1.el9_2.x86_64Red Hat Enterprise Linux 9 Update 2 Server for Intel EM64T
RHEL 9.35.14.0-362.8.1.el9_3.x86_64Red Hat Enterprise Linux 9 Update 3 Server for Intel EM64T
RHEL 9.45.14.0-427.13.1.el9_4.x86_64Red Hat Enterprise Linux 9 Update 4 Server for Intel EM64T
RHEL 9.55.14.0-503.11.1.el9_5.x86_64Red Hat Enterprise Linux 9 Update 5 Server for Intel EM64T
RHEL 9.65.14.0-570.12.1.el9_6.x86_64Red Hat Enterprise Linux 9 Update 6 Server for Intel EM64T
RHEL 9.75.14.0-611.5.1.el9_7.x86_64Red Hat Enterprise Linux 9 Update 7 Server for Intel EM64T
RHEL 9.85.14.0-687.5.3.el9_8.x86_64Red Hat Enterprise Linux 9 Update 8 Server for Intel EM64T
Rocky Linux 10.06.12.0-55.12.1.el10_0.x86_64Rocky Linux 10 Server for Intel EM64T
Rocky Linux 10.16.12.0-124.8.1.el10_1.x86_64Rocky Linux 10 Update 1 Server for Intel EM64T
Rocky Linux 10.26.12.0-211.16.1.el10_2.0.1.x86_64Rocky Linux 10 Update 2 Server for Intel EM64T
Rocky Linux 8.104.18.0-553.el8_10.x86_64Rocky Linux 8 Update 10 Server for Intel EM64T
Rocky Linux 8.64.18.0-372.9.1.el8.x86_64Rocky Linux 8 Update 6 Server for Intel EM64T
Rocky Linux 8.74.18.0-425.3.1.el8.x86_64Rocky Linux 8 Update 7 Server for Intel EM64T
Rocky Linux 8.84.18.0-477.10.1.el8_8.x86_64Rocky Linux 8 Update 8 Server for Intel EM64T
Rocky Linux 8.94.18.0-513.5.1.el8_9.x86_64Rocky Linux 8 Update 9 Server for Intel EM64T
Rocky Linux 9.05.14.0-70.13.1.el9_0.x86_64Rocky Linux 9 Server for Intel EM64T
Rocky Linux 9.15.14.0-162.6.1.el9_1.x86_64Rocky Linux 9 Update 1 Server for Intel EM64T
Rocky Linux 9.25.14.0-284.11.1.el9_2.x86_64Rocky Linux 9 Update 2 Server for Intel EM64T
Rocky Linux 9.35.14.0-362.8.1.el9_3.x86_64Rocky Linux 9 Update 3 Server for Intel EM64T
Rocky Linux 9.45.14.0-427.13.1.el9_4.x86_64Rocky Linux 9 Update 4 Server for Intel EM64T
Rocky Linux 9.55.14.0-503.14.1.el9_5.x86_64Rocky Linux 9 Update 5 Server for Intel EM64T
Rocky Linux 9.65.14.0-570.17.1.el9_6.x86_64Rocky Linux 9 Update 6 Server for Intel EM64T
Rocky Linux 9.75.14.0-611.5.1.el9_7.x86_64Rocky Linux 9 Update 7 Server for Intel EM64T
Rocky Linux 9.85.14.0-687.10.1.el9_8.0.1.x86_64Rocky Linux 9 Update 8 Server for Intel EM64T
SLES 15 SP45.14.21-150400.22-defaultSUSE Linux Enterprise Server 15 Service Pack 4 for AMD64 & Intel64
SLES 15 SP66.4.0-150600.21-defaultSUSE Linux Enterprise Server 15 Service Pack 6 for AMD64 & Intel64
Ubuntu 20.04.6 LTS5.4.0-144-genericUbuntu 20.04.6 LTS Server Edition for Intel EM64T
Ubuntu 22.04 LTS5.15.0-25-genericUbuntu 22.04 LTS Server Edition for Intel EM64T
Ubuntu 22.04.5 LTS5.15.0-119-genericUbuntu 22.04.5 LTS Server Edition for Intel EM64T
Ubuntu 24.04 LTS6.8.0-31-genericUbuntu 24.04 LTS Server Edition for Intel EM64T
Ubuntu 24.04.3 LTS6.8.0-71-genericUbuntu 24.04.3 LTS Server Edition for Intel EM64T
VMware ESXi 7.0 U3build-18644231VMware ESXi 7.0 Update 3 for Intel EM64T
VMware ESXi 8.0build-20513097VMware ESXi 8.0 for Intel EM64T
VMware ESXi 8.0 U1build-21495797VMware ESXi 8.0 Update 1 for Intel EM64T
VMware ESXi 8.0 U3build-24022510VMware ESXi 8.0 Update 3 for Intel EM64T
VMware ESXi 9.0build-24755229VMware ESXi 9.0 for Intel EM64T
VMware ESXi 9.1build-25370933VMware ESXi 9.1 for Intel EM64T
Windows Server 2019Build 17763Microsoft Windows Server 2019 x64
Windows Server 2022Build 20348Microsoft Windows Server 2022 x64
Windows Server 2025Build 26100Microsoft Windows Server 2025 x64
openEuler 22.03 LTS SP15.10.0-136.12.0.86.oe2203sp1.x86_64openEuler 22.03 LTS SP1 (powered by openEuler)
openEuler 22.03 LTS SP35.10.0-182.0.0.95.oe2203sp3.x86_64openEuler 22.03 LTS SP3 (powered by openEuler)

Configuring, expanding or replacing this server? Send us your part list or BOM for a fast quotation.

Request a Quote

Selecting components for the G5500 V7

These points from the matrix matter when configuring or expanding a unit:

  • Choose the processor to the workload. Validated options include models across the range, including the Gold 5415, Platinum 8458P and Silver 4516Y, with up to 64 cores per socket.
  • Memory: DDR5 RDIMMs from 16GB to 128GB at up to 6400 MT/s. Give us your capacity target and we will confirm the supported DIMM population and channel rules.
  • RAID levels follow the controller. The validated controllers support RAID 0, 1, 5, 6, 10, 50, 60. Cacheless entry cards suit boot and mirroring; cached cards with a supercapacitor enable parity RAID for data arrays; JBOD/IT cards provide passthrough to software RAID.
  • Storage mix. Validated options include SAS/SATA drives up to 20 TB and PCIe NVMe SSDs up to 8 TB. Backplane and tray variants are listed separately under Drive Backplanes.
  • Networking from 10GbE to 200GbE. OCP 3.0 and PCIe adapters are validated for the listed speeds; some SKUs include optical modules and others do not, so check the part description.
  • Power: 2000–3000W supplies. Platinum and titanium-rated AC units are listed, with redundant pairs for high availability; confirm the rating your GPU and drive population require.

Reference workload profiles

These profiles show how validated components combine; each is configured and quoted to order.

  • AI training: maximum supported GPUs with NVLink/fabric, high-core CPUs, large memory, titanium PSU.
  • AI inference / serving: right-sized GPU count, NVMe for models, high-throughput networking.
  • Scientific / HPC compute: GPUs plus high-frequency CPUs, ECC memory, InfiniBand.
  • GPU virtualization / VDI: virtualised GPUs, many users, fast boot and network storage.

The G5500 V7 in the FusionServer range

The numbered FusionServer generations make it straightforward to choose between current and supported hardware. The G5500 V7 is a V7 platform: 4th/5th Generation Intel Xeon Scalable, DDR5, PCIe 4.0/5.0.

Earlier supported generations remain useful:

  • V6: 3rd Generation Intel Xeon Scalable, DDR4, PCIe 4.0 — supported, cost-effective for standardised or budget projects.
  • V5: 1st/2nd Generation Intel Xeon Scalable, DDR4, PCIe 3.0 — supported, cost-effective for standardised or budget projects.

We supply new systems with manufacturer warranty and can source validated parts for earlier generations when a budget, software-licensing or support window calls for them. Ask us which generation fits.

G5500 V7 — compatibility FAQ

Which processors does the G5500 V7 support?

The matrix lists models across the range, including the Gold 5415, Platinum 8458P and Silver 4516Y, with up to 64 cores per socket. Confirm the thermal and power envelope for your chassis and PSU before ordering.

What memory can I install?

Validated DDR5 RDIMMs range from 16GB to 128GB at up to 6400 MT/s. Tell us your capacity target and we will confirm the supported DIMM population.

Which RAID levels are supported?

Validated controllers support RAID 0, 1, 5, 6, 10, 50, 60. Choose a cached card with a supercapacitor for parity RAID (5/6/50/60), an entry card for 0/1/10, or an IT/JBOD card for software RAID passthrough.

What drives are validated?

The matrix lists SAS/SATA drives up to 20 TB and NVMe SSDs up to 8 TB. See the Hard Drives and NVMe tabs for the full list, form factors and current status.

What network speeds are supported?

Validated OCP and PCIe adapters cover 10GbE, 25GbE, 200GbE. Note whether a SKU includes optical modules; we can supply matched optics if required.

What power supplies are available?

The list runs from 2000W to 3000W in platinum and titanium ratings. Redundant pairs can be configured for high availability; size the PSU to your CPU, GPU and drive load.

Which operating systems are certified?

The OS matrix lists 56 certified builds, including Red Hat Enterprise Linux, Rocky Linux, SUSE Linux Enterprise Server, Ubuntu, VMware ESXi, Windows Server, each with its exact kernel or build string. Additional builds can often be confirmed on request.

What do the lifecycle statuses mean?

Current/GA parts are in production; PILOT and DEVELOP parts are under limited rollout or qualification; EOM parts are out of marketing but supported as spares. Prefer Current parts for new builds.

Can you supply the server or just parts?

Both. We configure complete systems and supply every validated component listed here with warranty. Send a part list or BOM for a fast quotation.

Request a Quote  Look up a part number  All xFusion models

Leave a message