DELL CERTIFIED REDUNDANT POWER
Dell PowerEdge Power Supplies — Redundant Hot-Plug PSUs
Genuine Dell-certified redundant hot-plug power supplies for PowerEdge servers, from 495W to 2800W, Platinum and Titanium efficiency, with AC, -48V DC and HVDC options — matched by generation and label.
A failed PSU should be replaced with the exact same Dell generation and label type — mixing power supplies across PowerEdge generations is unsupported even at identical wattage. We supply genuine hot-plug redundant PSUs matched to your service tag, including AC, -48V DC and high-voltage DC options, so a replacement or upgrade runs correctly the first time.
PSU options we supply
Standard redundant AC
Common 495W, 750W, 800W and 1100W hot-plug AC PSUs for general rack/tower deployments.
High-wattage AC
1400W, 1600W, 1800W, 2000W, 2400W and 2800W PSUs for dense, GPU and multi-drive configurations.
Platinum efficiency
High-efficiency Platinum PSUs balancing cost, power draw and heat for most workloads.
Titanium efficiency
Top-tier Titanium PSUs, some rated for 200-240VAC or HVDC only, maximizing data-center efficiency.
-48V DC / HVDC
DC and mixed-mode high-voltage DC PSUs for telco and data-center DC power architectures.
Generation matched
Same Extended Power Performance (EPP) label and generation as the existing unit to avoid mismatch.
Typical applications
- Replacing a failed or warning hot-plug PSU
- Restoring 1+1 redundancy on a single-PSU server
- Upgrading wattage for added GPUs or drives
- Matching -48V DC / HVDC for facility power
Dell redundant PSU options at a glance
Compatible systems are verified against Dell’s official PSU compatibility listings; same-wattage Delta/LiteOn builds can differ, so match the exact p/n. Multi-generational PSUs fit the listed generations only.
| Wattages | 495, 550, 600, 700, 750, 800, 1100, 1400, 1600, 1800, 2000, 2400, 2800W |
|---|---|
| Efficiency | 80 Plus Platinum and Titanium |
| Input types | AC, -48V DC, mixed-mode HVDC (model dependent) |
| Connectors | C14 (lower wattage) / C20 (high wattage) |
| Redundancy | 1+1 redundant hot-plug, configurable hot spare |
| Matching rule | Same generation and EPP label; cross-gen mixing unsupported |
| Condition | New, factory sealed genuine Dell PSUs |
Dell PowerEdge PSU part numbers
Dell order codes (450-/486- prefixes) for factory-built configurations; some codes are region or chassis specific. Input type, efficiency and redundancy label vary by generation — match the existing PSU label and your service tag, and send us any code for an exact quote.
| Power supply | Dell p/n | Compatible PowerEdge systems |
|---|---|---|
| 495W Platinum hot-plug AC PSU | 450-AEBM | R530, R540, R630, R640, R730, R730XD, R730XD XL, R740, R740XD, R7415, R7425, R7515, T330, T340, T430, T440, T630, T640 |
| 495W hot-plug AC PSU | 450-AHFI | R7415 |
| 550W hot-plug PSU | 450-AEKP | R340, R430, R440, R6415, R6515, XR2 |
| 600W hot-plug AC PSU | 450-AKPR | R360, R450, R550, R650XS, R660, R750XS, R760XS, T360 |
| 700W DC redundant customer kit PSU | 450-ACGW | PowerVault MD3600f / MD3620f / MD3620i storage enclosures (not PowerEdge) |
| 700W Titanium mixed-mode HLAC PSU (Delta) | 450-AMIH | HS5610, HS5620, R260, R360, R660XS, R6615, R760XD2, R760XS, T360 |
| 700W Titanium mixed-mode HLAC PSU (LiteOn) | 450-AMJC | HS5610, R250, R260, R350, R450, R550, R650, R650XS, R6525, R6615, R760XD2, R760XS, T350, XR11, XR12 |
| 700W Titanium mixed-mode HLAC PSU (Delta) | 450-BBLS | T550, T560 |
| 700W Titanium mixed-mode HLAC PSU (LiteOn) | 450-BBMB | T550, T560 |
| 750W Titanium hot-plug AC PSU, 200-240V | 450-AEES | R630, R640, R730, R730XD, R740, R740XD, R7415, R7425, R7515, R840, T630, T640 |
| 750W mixed-mode 240V DC hot-plug PSU | 450-AHOY | R520, R530, R620, R630, R630XL, R640, R720, R720XD, R730, R730XD, R730XD XL, R730XL, R740XD, R820, R920, R940XA, T620, T630 |
| 750W hot-plug AC PSU | 450-AJRP | R540, R640, R740 |
| 800W mixed-mode non-redundant PSU | 450-AKMG | HS5610, R450, R550, R650, R650XS, R660, R6615, R6625, R750, R750XS, R760, R760XS, XR11, XR12, XR5610, XR7620 |
| 800W hot-plug 2U non-redundant PSU | 450-ALEL | R660, R760, R7615, R7625 |
| 1100W Platinum hot-plug AC PSU | 450-AEBL | C4130, FX2, R530, R540, R630, R640, R730, R730XD, R730XD XL, R740, R740XD, R740XD2, R7415, R7425, R7515, R830, R840, R940, T430, T440, T630, T640 |
| 1100W HVDC 336V hot-plug PSU | 450-AHPJ | R540, R630, R630XL, R640, R730, R730XD, R730XD XL, R730XL, R740, R740XD, R940, R940XA |
| 1100W mixed-mode AC/HVDC hot-plug PSU (config D) | 450-AKKX | HS5610, HS5620, R650, R660, R660XS, R6615, R6625, R750, R750XS, R760XD2, R760XS, XR5610, XR7620 |
| 1100W mixed-mode AC/HVDC hot-plug PSU (config L) | 450-AKKY | HS5610, HS5620, R650, R660, R6615, R6625, R750, R750XS, R760XD2, R760XS, XR5610, XR7620 |
| 1100W -48V DC hot-plug PSU | 450-AKPJ | HS5610, R450, R550, R650, R650XS, R660, R660XS, R6615, R6625, R750XS, R760XD2, R760XS, XR11, XR12, XR5610, XR7620 |
| 1100W -48V DC hot-plug 2U PSU | 450-ALEJ | R660, R760, R7615, R7625 |
| 1100W Titanium mixed-mode HLAC PSU (Delta) | 450-ALEM | R7615, R7625 |
| 1100W Titanium mixed-mode HLAC PSU (LiteOn) | 450-BBMC | T550, T560 |
| 1100W Titanium mixed-mode HLAC PSU (4U) | 450-BBXG | R960 |
| 1100W Platinum hot-plug redundant PSU | 5G4WK | R540, R640, R6415, R740, R740XD, R740XD2, R7415, R7425, R840, R940, R940XA |
| 1400W non-redundant hot-plug PSU | 450-AIYU | HS5610, HS5620, R650, R650XS, R660, R6615, R6625, R750XA, R750XS, R760XD2, R760XS, XR11, XR12, XR4000R, XR5610, XR7620 |
| 1400W non-redundant hot-plug AC PSU | 450-AKMJ | R750 |
| 1400W mixed-mode reverse-airflow PSU, customer install | 450-AKPM | XR11, XR12, XR4000R, XR4000Z |
| 1400W non-redundant hot-plug AC PSU | 450-AKYD | HS5610, HS5620, R660, R660XS, R6615, R6625, R760XD2, R760XS, XR4000R, XR5610, XR7620 |
| 1400W Titanium 277VAC / 260-400VDC PSU | 450-BCGV | HS5620, R660, R660XS, R6615, R6625, R760XS |
| 1600W Platinum hot-plug AC PSU, customer kit | 450-AEPB | FC630, M630, R640, R730XD, R730XD XL, R740, R740XD, R7415, R7425, R7515, R830, R840, R940, T640 |
| 1600W redundant AC PSU | 450-AHPE | C4130, FC630, M630, R640, R730XD, R730XD XL, R740XD, R7415, R7425, R830, R940, R940XA, T630, T640 |
| 1800W Titanium 2U hot-plug PSU | 450-AMEX | R760, R7615, R7625 |
| 1800W Titanium mixed-mode HLAC PSU (LiteOn) | 450-AMJE | C6600, HS5610, HS5620, R6615, R6625, R760XD2, R760XS, XR7620 |
| 1800W Titanium mixed-mode HLAC PSU | 450-AMJM | C6600, HS5610, HS5620, R660, R660XS, R6615, R6625, R760XD2, R760XS, XR7620 |
| 1800W Titanium mixed-mode HLAC PSU (Delta) | 450-BBMH | T560 |
| 2000W Platinum hot-plug AC PSU | 450-AENT | C4130, C4140, FX2, R530, R740, R740XD, R7425, R840, R940, T430, T630, T640 |
| 2000W non-redundant PSU | 450-AHPC | C4130, FX2, R530, R740XD, R940, R940XA, T430, T630, T640 |
| 2400W Platinum hot-plug AC PSU | 450-AGFW | C4140, R740, R740XD, R7425, R840, R940, T640 |
| 2400W hot-plug AC PSU | 450-AJPV | C6600 |
| 2400W mixed-mode PSU (4U) | 450-BBXM | R960 |
| 2400W Titanium mixed-mode PSU | 450-BDTN | R770, R770AP, R7715, R7725 |
| 2400W 2+2 redundant hot-plug PSU | 486-BBGE | T560 |
| 2800W Titanium mixed-mode HLAC PSU | 450-ALGT | C6600, R760, R760XA, R7625 |
What to specify when ordering
- Server model / service tag and existing PSU label
- Required wattage and efficiency rating
- Input type (AC / -48V DC / HVDC)
- Single replacement or matched redundant pair
Frequently asked questions
What power supplies fit my PowerEdge server?
Current PowerEdge systems use hot-plug redundant PSUs from 495W to 2800W. Send your service tag and we identify the exact wattage, input type and label for your chassis.
Can I replace a PSU while the server is running?
Yes. Redundant hot-plug PSUs are designed for replacement without powering down, provided the replacement matches the same Dell generation and label and the second PSU is healthy.
Why can’t I mix PSUs from different PowerEdge generations?
Dell does not support cross-generation PSU mixing even at the same wattage; it can cause a mismatch or prevent power-on. Units must share the same label type, such as EPP.
What wattage do I need for added GPUs or drives?
It depends on total component draw. We calculate headroom against your configuration and recommend the certified wattage that supports redundancy under full load.
What is the difference between Platinum and Titanium PSUs?
Titanium is the higher 80 Plus efficiency tier, reducing power loss and heat; some Titanium models are rated only for 200-240VAC or HVDC. Platinum offers strong efficiency more broadly.
Do you supply -48V DC or HVDC power supplies?
Yes. We supply -48V DC and mixed-mode high-voltage DC PSUs for telco and DC-powered data centers, matched to the systems that support them.
Should I buy one PSU or a matched pair?
For redundancy use two identical PSUs. If you are restoring 1+1 after a failure, replace only the faulty unit with the matching Dell part rather than introducing a different label.
What is PSU hot spare mode?
When enabled at low utilization, one PSU is put into a low-power state to improve efficiency while the other carries the load, with seamless handover as demand rises.
Why does a Titanium PSU list 200-240V only?
Some Titanium designs reach their rated efficiency and output only on 200-240VAC or HVDC. We confirm the input rating against your facility voltage before quoting.
Can I upgrade to a higher-wattage Dell PSU?
Within the same supported generation and chassis family, higher wattage options may be available as matched units. We verify certification rather than assuming fit by wattage.
Are C14 and C20 input connectors important?
Yes. Lower-wattage PSUs commonly use C14 while high-wattage units use C20, which affects the power cord and PDU socket. We specify the connector so cabling matches.
Are these genuine Dell power supplies, not generic?
They are genuine factory-sealed Dell PSUs with Dell part numbers and the correct firmware/label, avoiding the compatibility risk of aftermarket units.
What warranty covers a replacement PSU?
New genuine PSUs are quoted at 1 year, provided by Beijing Xinchuan Technology Co., Ltd. and stated on the order confirmation. We confirm the term for the specific part and coordinate support if a defect arises.
How fast does a replacement PSU ship?
In-stock PSUs are usually inspected and shipped within a few business days to minimize time outside redundancy; non-stock models depend on availability stated up front.
Request a quotation for this part
Share your model or service tag and the configuration you need. We confirm compatibility, then provide fixed pricing and shipping options.
serverbastion.com

WeChat