The FusionServer Pro 2158H V8-Genoa is 2U dual-socket server. It is a flexible 2U platform for compute and storage of this xFusion generation, designed for mixed compute and storage deployments. The platform runs on AMD EPYC 9004 Series (Genoa) with DDR5 memory and PCIe 5.0 expansion.
Below is the verified compatibility matrix for this model: 159 validated line items across 10 component categories and 4 certified operating-system builds, taken from xFusion’s official compatibility data and presented in English. Every part number listed is published by xFusion for this chassis; nothing is guessed or cross-filled from other models.
Compatibility matrix
Browse validated parts by category using the tabs below. Each tab shows its item count; search inside a tab by part number or keyword, and expand the full list. Parts marked Current are actively orderable; life-cycle parts are still supported and often available as spares. The OS table lists the exact certified kernel or build.
| P/N | Description / Specification | Status |
|---|---|---|
| 4102Y077 | X86 series-OLGA6096-2400MHz-0.55V/1.5V-64bit-360000mW-AMD EPYC 9004 Series-Genoa 9654-96Core | Current |
| 4102Y078 | X86 series-OLGA6096-3100MHz-0.55V/1.5V-64bit-360000mW-AMD EPYC 9004 Series-Genoa 9554-64Core | Current |
| 4102Y079 | X86 series-OLGA6096-2750MHz-0.55V/1.5V-64bit-290000mW-AMD EPYC 9004 Series-Genoa 9454-48Core | Current |
| 4102Y080 | X86 series-OLGA6096-3250MHz-0.55V/1.5V-64bit-280000mW-AMD EPYC 9004 Series-Genoa 9354-32Core | Current |
| 4102Y084 | X86 series-OLGA6096-2700MHz-0.55V/1.5V-64bit-210000mW-AMD EPYC 9004 Series-Genoa 9334-32Core | Current |
| 4102Y088 | X86 series-OLGA6096-3850MHz-0.55V/1.5V-64bit-320000mW-AMD EPYC 9004 Series-Genoa 9374F-32Core | Current |
| 4102Y105 | X86 series-OLGA6096-2250MHz-0.55V/1.5V-64bit-360000mW-AMD EPYC 9004 Series-Bergamo 9754-128Core | Current |
| P/N | Description / Specification | Status |
|---|---|---|
| 0251Y144 | memory module-2258 V7-generic memory-DDR5-RDIMM-64GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(4G*4bit)-3-way OEM code_overseas dedicated | Current |
| 0251Y145 | memory module-2258 V7-generic memory-DDR5-RDIMM-96GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(6G*4bit)-3-way OEM code_overseas dedicated | Current |
| 0251Y177 | memory module-2258 V7-generic memory-DDR5-RDIMM-64GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(4G*4bit)-XH-overseas dedicated | Current |
| 0251Y287 | memory module-2288H V7-M564R32-generic memory-DDR5-RDIMM-32GB-288pin-0.312ns-6400000KHz-1.1V-ECC-2Rank(2G*8bit)-overseas dedicated | Current |
| 0251Y288 | memory module-2288H V7-M564R64-generic memory-DDR5-RDIMM-64GB-288pin-0.312ns-6400000KHz-1.1V-ECC-2Rank(4G*4bit)-overseas dedicated | Current |
| 0251Y289 | memory module-2288H V7-M564R96-generic memory-DDR5-RDIMM-96GB-288pin-0.312ns-6400000KHz-1.1V-ECC-2Rank(6G*4bit)-3-way OEM code_overseas dedicated | Current |
| 0251Y291 | memory module-2288H V7-M556R64-generic memory-DDR5-RDIMM-64GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(4G*4bit)-for use in China only | Current |
| 0251Y297 | memory module-2288H V7-M564R32-generic memory-DDR5-RDIMM-32GB-288pin-0.312ns-6400000KHz-1.1V-ECC-2Rank(2G*8bit)-Samsung 1bnm-Turin platform prohibited | Current |
| 0251Y307 | memory module-2258 V7-M556R96-generic memory-DDR5-RDIMM-96GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(6G*4bit)-XH consumable virtual code-overseas dedicated | Current |
| 0251Y314 | memory module-M556R32-DDR5 RDIMM-32GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(2G*8bit) | Current |
| 0251Y315 | memory module-2288H V7-M564R32-generic memory-DDR5-RDIMM-32GB-288pin-0.312ns-6400000KHz-1.1V-ECC-2Rank(2G*8bit)-Samsung 1bnm-Turin platform prohibited | Current |
| 0251Y317 | memory module-2288H V7-generic memory-DDR5-RDIMM-64GB-288pin-0.312ns-6400000KHz-1.1V-ECC-2Rank(4G*4bit) | Current |
| 0251Y325 | memory module-2288H V7-M564R32-generic memory-DDR5-RDIMM-32GB-288pin-0.312ns-6400000KHz-1.1V-ECC-2Rank(2G*8bit)-Samsung 1bnm-Turin platform prohibited | Current |
| 0251Y326 | memory module-DDR5 RDIMM-64GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(4G*4bit) | Current |
| 0620Y029 | generic memory-DDR5-RDIMM-32GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(2G*8bit) | Current |
| 0620Y029-020 | generic memory-DDR5-RDIMM-32GB-288pin-0.312ns-6400000KHz-1.1V-ECC-2Rank(2G*8bit)-Samsung 1bnm-Turin platform prohibited | Current |
| 0620Y031 | generic memory-DDR5-RDIMM-64GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(4G*4bit) | Current |
| 0620Y031-004 | generic memory-DDR5-RDIMM-64GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(4G*4bit)-SK Hynix 1anm | Current |
| 0620Y031-005 | generic memory-DDR5-RDIMM-64GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(4G*4bit)-3-way OEM code_overseas dedicated | Current |
| 0620Y031-006 | generic memory-DDR5-RDIMM-64GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(4G*4bit)-XH consumable virtual code | Current |
| 0620Y031-009 | generic memory-DDR5-RDIMM-64GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(4G*4bit)-Xiaohongshu designated-Hynix 1anm | Current |
| 0620Y031-012 | generic memory-DDR5-RDIMM-64GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(4G*4bit)-CXMT G4 | Current |
| 0620Y031-024 | generic memory-DDR5-RDIMM-64GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(4G*4bit)-XH consumable virtual code-for use in China | Current |
| 0620Y032 | generic memory-DDR5-RDIMM-96GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(6G*4bit) | Current |
| 0620Y032-001 | generic memory-DDR5-RDIMM-96GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(6G*4bit)-SAMSUNG 1anm | Current |
| 0620Y032-008 | generic memory-DDR5-RDIMM-96GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(6G*4bit)-designated-model dedicated-SAMSUNG 1anm | Current |
| 0620Y032-009 | generic memory-DDR5-RDIMM-96GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(6G*4bit)-designated-model dedicated-longsys | Current |
| 0620Y032-011 | generic memory-DDR5-RDIMM-96GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(6G*4bit)-M321RYGA0PB0-CWMKH,customer designated | Current |
| 0620Y040 | generic memory-DDR5-RDIMM-32GB-288pin-0.312ns-6400000KHz-1.1V-ECC-2Rank(2G*8bit) | Current |
| 0620Y042 | generic memory-DDR5-RDIMM-64GB-288pin-0.312ns-6400000KHz-1.1V-ECC-2Rank(4G*4bit) | Current |
| 0620Y042-011 | generic memory-DDR5-RDIMM-64GB-288pin-0.312ns-6400000KHz-1.1V-ECC-2Rank(4G*4bit)-CXMT | Current |
| 0620Y043 | generic memory-DDR5-RDIMM-96GB-288pin-0.312ns-6400000KHz-1.1V-ECC-2Rank(6G*4bit) | Current |
| 0620Y031-003 | generic memory-DDR5-RDIMM-64GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(4G*4bit)-SAMSUNG 1anm | EOM |
| P/N | Description / Specification | Status |
|---|---|---|
| 0254Y364 | generic drive module-Servers-generic drive-24TB-SATA 6.0Gb/s-7.2K rpm-3.5 inch-hot-swap-internal-3.5 inch bracket-V7 dedicated | Current |
| 0255Y417 | SSD module-Servers-SSD-480GB-SATA 6Gb/s-read-intensive-PM893 series-2.5 inch(2.5 inch bracket)-V7 dedicated | Current |
| 0255Y418 | SSD module-Servers-SSD-480GB-SATA 6Gb/s-read-intensive-PM893 series-2.5 inch(3.5 inch bracket)-V7 dedicated | Current |
| 0255Y419 | SSD module-Servers-SSD-960GB-SATA 6Gb/s-read-intensive-PM893 series-2.5 inch(2.5 inch bracket)-V7 dedicated | Current |
| 0255Y420 | SSD module-Servers-SSD-960GB-SATA 6Gb/s-read-intensive-PM893 series-2.5 inch(3.5 inch bracket)-V7 dedicated | Current |
| 0255Y423 | SSD module-Servers-SSD-3840GB-SATA 6Gb/s-read-intensive-PM893 series-2.5 inch(2.5 inch bracket)-V7 dedicated | Current |
| 0255Y424 | SSD module-Servers-SSD-3840GB-SATA 6Gb/s-read-intensive-PM893 series-2.5 inch(3.5 inch bracket)-V7 dedicated | Current |
| 0255YCAK-001 | SSD module-Servers-SSD-480GB-SATA 6Gb/s-mixed read-write-S4620 series-2.5 inch(2.5 inch bracket)-V7 dedicated-Solidigm | Current |
| 0255YCAL-001 | SSD module-Servers-SSD-480GB-SATA 6Gb/s-mixed read-write-S4620 series-2.5 inch(3.5 inch bracket)-V7 dedicated-Solidigm | Current |
| 0255YCAM-001 | SSD module-Servers-SSD-960GB-SATA 6Gb/s-mixed read-write-S4620 series-2.5 inch(2.5 inch bracket)-V7 dedicated-Solidigm | Current |
| 0255YCAN-001 | SSD module-Servers-SSD-960GB-SATA 6Gb/s-mixed read-write-S4620 series-2.5 inch(3.5 inch bracket)-V7 dedicated-Solidigm | Current |
| 0255YCAP-001 | SSD module-Servers-SSD-1920GB-SATA 6Gb/s-mixed read-write-S4620 series-2.5 inch(2.5 inch bracket)-V7 dedicated-Solidigm | Current |
| 0255YCAQ-001 | SSD module-Servers-SSD-1920GB-SATA 6Gb/s-mixed read-write-S4620 series-2.5 inch(3.5 inch bracket)-V7 dedicated-Solidigm | Current |
| 0255YCAR-001 | SSD module-Servers-SSD-3840GB-SATA 6Gb/s-mixed read-write-S4620 series-2.5 inch(2.5 inch bracket)-V7 dedicated-Solidigm | Current |
| 0255YCAS-001 | SSD module-Servers-SSD-3840GB-SATA 6Gb/s-mixed read-write-S4620 series-2.5 inch(3.5 inch bracket)-V7 dedicated-Solidigm | Current |
| 0255YDUH | SSD module-Servers-SSD-480GB-SATA 6Gb/s-read-intensive-SE006 series-2.5 inch(2.5 inch bracket)-V7 dedicated | Current |
| 0255YDUJ | SSD module-Servers-SSD-480GB-SATA 6Gb/s-read-intensive-SE006 series-2.5 inch(3.5 inch bracket)-V7 dedicated | Current |
| 0255YDUM | SSD module-Servers-SSD-960GB-SATA 6Gb/s-read-intensive-SE006 series-2.5 inch(2.5 inch bracket)-V7 dedicated | Current |
| 0255YDUN | SSD module-Servers-SSD-960GB-SATA 6Gb/s-read-intensive-SE006 series-2.5 inch(3.5 inch bracket)-V7 dedicated | Current |
| 0255YDUR | SSD module-Servers-SSD-1920GB-SATA 6Gb/s-read-intensive-SE006 series-2.5 inch(2.5 inch bracket)-V7 dedicated | Current |
| 0255YDUS | SSD module-Servers-SSD-1920GB-SATA 6Gb/s-read-intensive-SE006 series-2.5 inch(3.5 inch bracket)-V7 dedicated | Current |
| 0255YDUW | SSD module-Servers-SSD-7680GB-SATA 6Gb/s-read-intensive-SE006 series-2.5 inch(2.5 inch bracket)-V7 dedicated | Current |
| 0255YDUX | SSD module-Servers-SSD-7680GB-SATA 6Gb/s-read-intensive-SE006 series-2.5 inch(3.5 inch bracket)-V7 dedicated | Current |
| 0255YDXA | SSD module-Servers-SSD-3840GB-SATA 6Gb/s-read-intensive-SE006 series-2.5 inch(2.5 inch bracket)-V7 dedicated | Current |
| 0255YDXB | SSD module-Servers-SSD-3840GB-SATA 6Gb/s-read-intensive-SE006 series-2.5 inch(3.5 inch bracket)-V7 dedicated | Current |
| 0255YESE | SSD module-Servers-SSD-960GB-SATA 6Gb/s-mixed read-write-S4620 series-2.5 inch(2.5 inch bracket)-V7 dedicated-Solidigm | Current |
| 0255YESS | SSD module-Servers-SSD-3840GB-SATA 6Gb/s-read-intensive-PM893 series-2.5 inch(2.5 inch bracket)-V7 dedicated | Current |
| 0255YEST | SSD module-Servers-SSD-3840GB-SATA 6Gb/s-read-intensive-PM893 series-2.5 inch(3.5 inch bracket)-V7 dedicated | Current |
| 0255YEUN | SSD module-Servers-SSD-480GB-SATA 6Gb/s-read-intensive-PM893 series-2.5 inch(2.5 inch bracket)-V7 dedicated | Current |
| 0255YEUR | SSD module-Servers-SSD-480GB-SATA 6Gb/s-read-intensive-PM893 series-2.5 inch(3.5 inch bracket)-V7 dedicated | Current |
| 0255YEVX | SSD module-Servers-SSD-3840GB-SATA 6Gb/s-mixed read-write-S4620 series-2.5 inch(2.5 inch bracket)-V7 dedicated-Solidigm | Current |
| 0255YEWE | SSD module-Servers-SSD-3840GB-SATA 6Gb/s-mixed read-write-S4620 series-2.5 inch(3.5 inch bracket)-V7 dedicated-Solidigm | Current |
| 0255YEWK | SSD module-Servers-SSD-1920GB-SATA 6Gb/s-mixed read-write-S4620 series-2.5 inch(2.5 inch bracket)-V7 dedicated-Solidigm | Current |
| 0255YEXB | SSD module-Servers-SSD-960GB-SATA 6Gb/s-mixed read-write-S4620 series-2.5 inch(3.5 inch bracket)-V7 dedicated-Solidigm | Current |
| 0255YEYM | SSD module-Servers-SSD-480GB-SATA 6Gb/s-mixed read-write-S4620 series-2.5 inch(3.5 inch bracket)-V7 dedicated-Solidigm | Current |
| 0255YEYQ | SSD module-Servers-SSD-480GB-SATA 6Gb/s-mixed read-write-S4620 series-2.5 inch(2.5 inch bracket)-V7 dedicated-Solidigm | Current |
| 0255YEYR | SSD module-Servers-SSD-1920GB-SATA 6Gb/s-mixed read-write-S4620 series-2.5 inch(3.5 inch bracket)-V7 dedicated-Solidigm | Current |
| 0255YFBD | SSD module-Servers-SSD-960GB-SATA 6Gb/s-read-intensive-PM893 series-2.5 inch(2.5 inch bracket)-V7 dedicated | Current |
| 0255YFBE | SSD module-Servers-SSD-960GB-SATA 6Gb/s-read-intensive-PM893 series-2.5 inch(3.5 inch bracket)-V7 dedicated | Current |
| P/N | Description / Specification | Status |
|---|---|---|
| 0255Y301 | SSD module-Servers-SSD-1920GB-NVMe PCIe-read-intensive-PM9A3 series-2.5 inch(2.5 inch bracket)-V7 dedicated | Current |
| 0255Y302 | SSD module-Servers-SSD-1920GB-NVMe PCIe-read-intensive-PM9A3 series-2.5 inch(3.5 inch bracket)-V7 dedicated | Current |
| 0255Y303 | SSD module-Servers-SSD-3840GB-NVMe PCIe-read-intensive-PM9A3 series-2.5 inch(2.5 inch bracket)-V7 dedicated | Current |
| 0255Y304 | SSD module-Servers-SSD-3840GB-NVMe PCIe-read-intensive-PM9A3 series-2.5 inch(3.5 inch bracket)-V7 dedicated | Current |
| 0255Y305 | SSD module-Servers-SSD-7680GB-NVMe PCIe-read-intensive-PM9A3 series-2.5 inch(2.5 inch bracket)-V7 dedicated | Current |
| 0255Y306 | SSD module-Servers-SSD-7680GB-NVMe PCIe-read-intensive-PM9A3 series-2.5 inch(3.5 inch bracket)-V7 dedicated | Current |
| 0255YABK | SSD module-Servers-SSD-7680GB-NVMe PCIe-read-intensive-R5100 series-2.5 inch(2.5 inch bracket)-V7 dedicated | Current |
| 0255YARV | SSD module-Servers-SSD-7680GB-NVMe PCIe-read-intensive-R5100 series-2.5 inch(3.5 inch bracket)-V7 dedicated | Current |
| 0255YBAN | SSD module-Servers-SSD-1920GB-NVMe PCIe-read-intensive-PE321 series-2.5 inch(2.5 inch bracket)-V7 dedicated | Current |
| 0255YBAP | SSD module-Servers-SSD-1920GB-NVMe PCIe-read-intensive-PE321 series-2.5 inch(3.5 inch bracket)-V7 dedicated | Current |
| 0255YBAQ | SSD module-Servers-SSD-3840GB-NVMe PCIe-read-intensive-PE321 series-2.5 inch(2.5 inch bracket)-V7 dedicated | Current |
| 0255YBAR | SSD module-Servers-SSD-3840GB-NVMe PCIe-read-intensive-PE321 series-2.5 inch(3.5 inch bracket)-V7 dedicated | Current |
| 0255YBAS | SSD module-Servers-SSD-7680GB-NVMe PCIe-read-intensive-PE321 series-2.5 inch(2.5 inch bracket)-V7 dedicated | Current |
| 0255YBAT | SSD module-Servers-SSD-7680GB-NVMe PCIe-read-intensive-PE321 series-2.5 inch(3.5 inch bracket)-V7 dedicated | Current |
| 0255YBUN | SSD module-Servers-SSD-6400GB-NVMe PCIe-mixed read-write-SP620 series-2.5 inch(2.5 inch bracket)-V7 dedicated | Current |
| 0255YBUP | SSD module-Servers-SSD-6400GB-NVMe PCIe-mixed read-write-SP620 series-2.5 inch(3.5 inch bracket)-V7 dedicated | Current |
| 0255YCEV-006 | SSD module-Servers-SSD-3840GB-PCIE 5.0 X4-NVMe PCIe-read-intensive-PM9D3a series-2.5 inch(2.5 inch bracket)-V7 dedicated | Current |
| 0255YCEX-007 | SSD module-Servers-SSD-7680GB-PCIE 5.0 X4-NVMe PCIe-read-intensive-PM9D3a series-2.5 inch(2.5 inch bracket)-V7 dedicated | Current |
| 0255YCFQ-003 | SSD module-Servers-SSD-1920GB-PCIE 5.0 X4-NVMe PCIe-read-intensive-PM9D3a series-2.5 inch(2.5 inch bracket)-V7 dedicated | Current |
| 0255YDXV | SSD module-Servers-SSD-7680GB-PCIE 5.0 X4-NVMe PCIe-read-intensive-R6101 series-2.5 inch(2.5 inch bracket)-V7 dedicated | Current |
| 0255YDXW | SSD module-Servers-SSD-7680GB-PCIE 5.0 X4-NVMe PCIe-read-intensive-R6101 series-2.5 inch(3.5 inch bracket)-V7 dedicated | Current |
| 0255YEBN | SSD module-Servers-SSD-6400GB-NVMe PCIe 5.0 X4-mixed read-write-R6301 series-2.5 inch(3.5 inch bracket)-V7 dedicated | Current |
| 0255YEBP | SSD module-Servers-SSD-6400GB-NVMe PCIe 5.0 X4-mixed read-write-R6301 series-2.5 inch(2.5 inch bracket)-V7 dedicated | Current |
| 0255YEGF | SSD module-Servers-SSD-3840GB-PCIE 5.0 X4-NVMe PCIe-read-intensive-R6101 series-2.5 inch(2.5 inch bracket)-V7 dedicated | Current |
| 0255YEGG | SSD module-Servers-SSD-3840GB-PCIE 5.0 X4-NVMe PCIe-read-intensive-R6101 series-2.5 inch(3.5 inch bracket)-V7 dedicated | Current |
| 0255YEGH | SSD module-Servers-SSD-3200GB-NVMe PCIe 5.0 X4-mixed read-write-R6301 series-2.5 inch(2.5 inch bracket)-V7 dedicated | Current |
| 0255YEGJ | SSD module-Servers-SSD-3200GB-NVMe PCIe 5.0 X4-mixed read-write-R6301 series-2.5 inch(3.5 inch bracket)-V7 dedicated | Current |
| 0255YESM | SSD module-Servers-SSD-7680GB-PCIE 5.0 X4-NVMe PCIe-read-intensive-PM9D3a series-2.5 inch(2.5 inch bracket)-V7 dedicated | Current |
| 0255YEUA | SSD module-Servers-SSD-1920GB-NVMe PCIe-read-intensive-PE321 series-2.5 inch(3.5 inch bracket)-V7 dedicated | Current |
| 0255YEUB | SSD module-Servers-SSD-1920GB-NVMe PCIe-read-intensive-PE321 series-2.5 inch(2.5 inch bracket)-V7 dedicated | Current |
| 0255YEWA | SSD module-Servers-SSD-3840GB-NVMe PCIe-read-intensive-PE321 series-2.5 inch(2.5 inch bracket)-V7 dedicated | Current |
| 0255YEWC | SSD module-Servers-SSD-3840GB-NVMe PCIe-read-intensive-PE321 series-2.5 inch(3.5 inch bracket)-V7 dedicated | Current |
| 0255YEWR | SSD module-Servers-SSD-7680GB-NVMe PCIe-read-intensive-PE321 series-2.5 inch(3.5 inch bracket)-V7 dedicated | Current |
| 0255YEWW | SSD module-Servers-SSD-7680GB-NVMe PCIe-read-intensive-PE321 series-2.5 inch(2.5 inch bracket)-V7 dedicated | Current |
| 0255YFCV | SSD module-Servers-SSD-7680GB-NVMe PCIe-read-intensive-PM9A3 series-2.5 inch(3.5 inch bracket)-V7 dedicated | Current |
| 0255YFCY | SSD module-Servers-SSD-7680GB-NVMe PCIe-read-intensive-PM9A3 series-2.5 inch(2.5 inch bracket)-V7 dedicated | Current |
| 0255YFDK | SSD module-Servers-SSD-1920GB-NVMe PCIe-read-intensive-PM9A3 series-2.5 inch(2.5 inch bracket)-V7 dedicated | Current |
| 0255YFDN | SSD module-Servers-SSD-1920GB-NVMe PCIe-read-intensive-PM9A3 series-2.5 inch(3.5 inch bracket)-V7 dedicated | Current |
| 0255YFDV | SSD module-Servers-SSD-3840GB-NVMe PCIe-read-intensive-PM9A3 series-2.5 inch(2.5 inch bracket)-V7 dedicated | Current |
| 0255YFDW | SSD module-Servers-SSD-3840GB-NVMe PCIe-read-intensive-PM9A3 series-2.5 inch(3.5 inch bracket)-V7 dedicated | Current |
| P/N | Description / Specification | Status |
|---|---|---|
| 0231Y131 | function module-9560-16i 8G-CN2M956016I8G-9560-16i 8G other board card-12G SAS RAID card-8G cache-16*12Gb/s SAS PHY-2 slimline internal interface-PCIE 4.0 X8-Vendor ID 1000-Device ID 10E2-Subvendor ID 1000-Subdevice ID 4000 | Current |
| 0231Y735 | function module-9540-8i-CN2M95408I-PCIE 4.0 X8-Vendor ID 1000-Device ID 10E6-1-Subvendor ID 1000-Subdevice ID 40D5-12G SAS RAID-9540-8i-x8 PCIe 4.0-9540-8i SAS RAID Card,SAS3808,No CacheVault,12Gb/s SAS,6Gb/s SATA,PCIe(NVMe)-9540-8i | Current |
| 0256Y064 | RAID card module-Public Module-BC5M01RLAH1-XP270-M2-(SAS3808-BootCard)-M.2 RAID standardcard-RAID0,1,JBOD-No Cache-supports sideband management-half-height half-length-full-height bracket-PCIe 4.0 x8 | Current |
| 0256Y066 | RAID card module-Public Module-BC5M02RLAH1-XP270-M2-(SAS3808-BootCard)-M.2 RAID standardcard-RAID0,1,JBOD-No Cache-supports sideband management-half-height half-length-half-height bracket-PCIe 4.0 x8 | Current |
| 0256Y149 | RAID card module-2158H V8-BC5M01RLAE-XC170-M-8i-(SAS3808iMR)-SAS/SATA RAID cable card-RAID0,1,10-12Gb/s-no Cache-supports sideband management | Current |
| 0256Y150 | RAID card module-2158H V8-XC470C-M-8i-RAID cable card-XC470C-M-8i 4G(SAS3908)-RAID0,1,5,6,10,50,60-12Gb/s-4GB Cache-supports supercap & sideband management-PCIE 4.0 X8-Vendor ID 1000-Device ID 10E2-Subvendor ID 1F24-Subdevice ID 3000 | Current |
| 0256Y172 | RAID card module-2158H V8-XC470C-M-16i-SAS/SATA RAID cable card-XC470C-M-16i 4G-(SAS3916)-RAID0,1,5,6,10,50,60-12Gb/s-4GB Cache-PCIE 4.0 X8-Vendor ID 1000-Device ID 10E2-Subvendor ID 1F24-Subdevice ID 3001 | Current |
| 0256Y174 | RAID card module-2288H V7-9560-8i 4G-12G SAS RAID card-9560-8i-(SAS3908)-CVPM05-12Gb/s SAS-6Gb/s SATA-PCIe(NVMe)-4G CacheVault-PCIE 4.0 X8-Vendor ID 1000-Device ID 10E2-Subvendor ID 1000-Subdevice ID 4010 | Current |
| 0256Y179 | RAID card module-2288H V7-9560-16i 8G-12G SAS RAID card-9560-16i-(SAS3916)-CVPM05-12Gb/s SAS,6Gb/s SATA,PCIe(NVMe)-8G CacheVault-PCIE 4.0 X8-Vendor ID 1000-Device ID 10E2-Subvendor ID 1000-Subdevice ID 4000 | Current |
| 0231Y129 | function module-9560-8i 4G-CN2M95608I4G-9560-8i 4G other board card-12G SAS RAID card-4G cache-8*12Gb/s SAS PHY-1 slimline internal interface-PCIE 4.0 X8-Vendor ID 1000-Device ID 10E2-Subvendor ID 1000-Subdevice ID 4010 | EOM |
| P/N | Description / Specification | Status |
|---|---|---|
| 0231Y809 | function module-Servers-CN2M04ITGG1-XP330 Ethernet adapter-10Gb optical port(Intel X710)-dual-port-SFP+(optical module not included)-half-height half-length(incl. half-height & full-height brackets)-PCIe 3.0 x8 | Current |
| 0256Y025 | RAID card module-2288H V6-9500-8e-PCIE 4.0 X8-Vendor ID 1000-Device ID 00E6-1-Subvendor ID 1000-Subdevice ID 4080-12G SAS RAID-x8 PCIe 4.0-9500-8e SAS RAID Card,SAS3808,No CacheVault,12Gb/s SAS,6Gb/s SATA,PCIe(NVMe)-9500-8e | Current |
| 0257Y099 | PCIe-network adapter-2288H V6-E810XXVDA2G1P5-network adapter-25G optical port(E810XXVDA2G1P5 978333)-dual-port-SFP28(optical module not included)-PCIE 4.0 X8-8086-159b|0003-2-with driver package | Current |
| 0257Y102 | PCIe-network adapter-2288H V6-MCX631102AN-ADAT-network adapter-25 GE-64bit-SFP28-2-PCIE 4.0 x8-15b3-101f-2-with driver package | Current |
| 0257Y150 | PCIe-network adapter-2288H V6-MCX623106AN-CDAT-network adapter-100Gb optical port(MCX623106AN-CDAT)-dual-port-QSFP56(optical module not included)-half-height half-length-PCIE 4.0 x16-15b3-101d-2-with driver package | Current |
| 0257Y151 | PCIe-network adapter-2288H V6-BCM957412A4120AC-network adapter-10 Gigabit-64bit-SFP+-2-PCIE 3.0 x8-14e4-16d6-2-with driver package | Current |
| 0257Y246 | PCIe-IB card-G8600 V7-MCX755106AS-HEAT-Infiniband MCX755106AS-HEAT-200Gb/s NDR200 IB,dual-port QSFP112-PCIE 5.0 x16-Vendor ID 15B3-Device ID 1021-2-Subvendor ID 15B3-Subdevice ID 0022(optical module not included) | Current |
| P/N | Description / Specification | Status |
|---|---|---|
| 0257Y104 | PCIe-network adapter-2288H V6-X710DA2OCPV3-network adapter-2*10GE-64bit-SFP+(without optical module)-2 ports-PCIE 3.0 x8-8086-1572-2-OCP 3.0-with driver package | Current |
| 0257Y108 | PCIe-network adapter-2288H V6-BCM957414N4140C-Ethernet adapter-2*25GE(Broadcom BCM57414)-dual-port-SFP28-PCIE 3.0 x8-14e4-16d7-2,OCP 3.0-with driver package | Current |
| 0257Y131 | PCIe-network adapter-2288H V6-BCM957508-N2100G-network adapter-100 Gigabit-64bit-QSFP28-2 ports-PCIE 4.0 x16-14e4-1750-2,OCP-with driver package | Current |
| P/N | Description / Specification | Status |
|---|---|---|
| 0302012403 | manufactured board-2288H V7-BC15HBBB-12*3.5 inch SAS/SATA pass-through(incl. 4*NVMe)drive backplane-1*2 | NONE |
| 0302012415 | manufactured board-2288H V7-BC15MSMA-internal M.2 riser/adapter card,supports PCH SATA/PCIe-2*1 | NONE |
| 0302012452 | manufactured board-2288H V7-BC15HBBE-IO1/IO2 2*2.5 inch SAS/SATA drive backplane-2*2 | NONE |
| 0302012464 | manufactured board-2288H V7-BC15HBBI-IO3 4*SAS/SATA/NVMe drive backplane-1*4 | NONE |
| 0302Y125 | manufactured board-2288H V7-BC15NHBI-8*SAS/SATA+16NVME pass-through drive backplane-1*2 | NONE |
| 0302Y258 | manufactured board-2288H V7-BC15NHBK-8*2.5 inch SAS/SATA/NVMe drive backplane-1*2 | NONE |
| 0302Y683 | manufactured board-2258 V7-BC15HBBS-IO3 4*NVMe drive backplane-1*4 | NONE |
| 0302Y689 | manufactured board-2158H V8-BC26HBMA-PCIe to SATA M.2 backplane-1*1 | NONE |
| 0302Y860 | manufactured board-2288 V8-BC16NHBC-8*2.5 inch SAS/SATA/NVMe 3Cage drive backplane-1*2 | NONE |
| P/N | Description / Specification | Status |
|---|---|---|
| 02313XSF | server platinum 900W 2.0 versionAC power supply-ST(model PAC900S12-B2,interface IEC 320-C14) | Current |
| 0231Y019 | server platinum 2000W 2.0 versionAC power supply(model PAC2000S12-B1,interface IEC 320-C14) | Current |
| 0231Y021 | HVDC1500WB power supply module(model PHD1500S12-B2,interface Rongfeng RF-203 high-voltage input terminal) | Current |
| 0231Y023 | 3000W titanium AC power supply(model PAC3000S12-T1,interface IEC 320-C20) | Current |
| 0231Y025 | server titanium 2000W AC power supply module(model PAC2000S12-T1,interface IEC 320-C14) | Current |
| 0231Y033 | server platinum 1500W 2.0 versionAC power supply(model PAC1500S12-B1,interface IEC 320-C14) | Current |
| 0231YEKU | primary power supply-XA3000-server titanium 3000W AC power supply(model XA3000,interface IEC 320-C20) | Current |
| P/N | Description / Specification | Status |
|---|---|---|
| 0255Y697 | SSD module-Servers-M.2 SSD-SATA 6Gb/s-480GB-80.0mm * 22.0mm * 3.58 mm(hot-swappable)-ER3 series | Current |
| 0255Y698 | SSD module-Servers-M.2 SSD-SATA 6Gb/s-480GB-80.0mm * 22.0mm * 3.58 mm(non-hot-swappable)-ER3 series | Current |
| 0255YFBA | SSD module-Servers-M.2 SSD-SATA 6Gb/s-480GB-80.0mm * 22.0mm * 3.58 mm(hot-swappable)-ER3 series | Current |
| 0255YFBP | SSD module-Servers-M.2 SSD-SATA 6Gb/s-480GB-80.0mm * 22.0mm * 3.58 mm(non-hot-swappable)-ER3 series | Current |
Operating System Compatibility
| Operating System | Version / Kernel | Release |
|---|---|---|
| RHEL 9.0 | 5.14.0-70.13.1.el9_0.x86_64 | Red Hat Enterprise Linux 9 Server for Intel EM64T |
| Rocky Linux 9.0 | 5.14.0-70.13.1.el9_0.x86_64 | Rocky Linux 9 Server for Intel EM64T |
| VMware ESXi 8.0 | build-20513097 | VMware ESXi 8.0 for Intel EM64T |
| Windows Server 2022 | Build 20348 | Microsoft Windows Server 2022 x64 |
Configuring, expanding or replacing this server? Send us your part list or BOM for a fast quotation.
Request a QuoteSelecting components for the 2158H V8-Genoa
These points from the matrix matter when configuring or expanding a unit:
- Choose the processor to the workload. Validated options include models across the range, including the 9334, 9454 and 9754, with up to 128 cores per socket.
- Memory: DDR5 RDIMMs from 32GB to 96GB at up to 6400 MT/s. Give us your capacity target and we will confirm the supported DIMM population and channel rules.
- RAID levels follow the controller. The validated controllers support RAID 1, 5, 6, 10, 50, 60, JBOD. Cacheless entry cards suit boot and mirroring; cached cards with a supercapacitor enable parity RAID for data arrays; JBOD/IT cards provide passthrough to software RAID.
- Storage mix. Validated options include SAS/SATA drives up to 24 TB and PCIe NVMe SSDs up to 8 TB. Backplane and tray variants are listed separately under Drive Backplanes.
- Networking from 10GbE to 100GbE. OCP 3.0 and PCIe adapters are validated for the listed speeds; some SKUs include optical modules and others do not, so check the part description.
- Power: 900–3000W supplies. Platinum and titanium-rated AC units are listed, with redundant pairs for high availability; confirm the rating your component and drive population require.
Reference workload profiles
These profiles show how validated components combine; each is configured and quoted to order.
- Virtualization / private cloud: balanced processors, a large RDIMM footprint, hardware RAID with cache and redundant power.
- Database / in-memory: high-frequency processors, maximum memory, PCIe NVMe for log and hot data.
- All-flash node: parity-capable RAID or HBA, a full set of NVMe SSDs, high-wattage titanium PSU.
- Storage / backup node: cached RAID or JBOD passthrough, a full set of high-capacity drives, high-wattage PSU.
- General application / infra: mid-bin processors, moderate memory and storage, cost-effective networking.
The 2158H V8-Genoa in the FusionServer range
The numbered FusionServer generations make it straightforward to choose between current and supported hardware. The 2158H V8-Genoa is a V8 platform: AMD EPYC 9004 Series (Genoa), DDR5, PCIe 5.0.
Earlier supported generations remain useful:
- V7: 4th/5th Generation Intel Xeon Scalable, DDR5, PCIe 4.0/5.0 — supported, cost-effective for standardised or budget projects.
- V6: 3rd Generation Intel Xeon Scalable, DDR4, PCIe 4.0 — supported, cost-effective for standardised or budget projects.
- V5: 1st/2nd Generation Intel Xeon Scalable, DDR4, PCIe 3.0 — supported, cost-effective for standardised or budget projects.
We supply new systems with manufacturer warranty and can source validated parts for earlier generations when a budget, software-licensing or support window calls for them. Ask us which generation fits.
2158H V8-Genoa — compatibility FAQ
Which processors does the 2158H V8-Genoa support?
The matrix lists models across the range, including the 9334, 9454 and 9754, with up to 128 cores per socket. Confirm the thermal and power envelope for your chassis and PSU before ordering.
What memory can I install?
Validated DDR5 RDIMMs range from 32GB to 96GB at up to 6400 MT/s. Tell us your capacity target and we will confirm the supported DIMM population.
Which RAID levels are supported?
Validated controllers support RAID 1, 5, 6, 10, 50, 60, JBOD. Choose a cached card with a supercapacitor for parity RAID (5/6/50/60), an entry card for 0/1/10, or an IT/JBOD card for software RAID passthrough.
What drives are validated?
The matrix lists SAS/SATA drives up to 24 TB and NVMe SSDs up to 8 TB. See the Hard Drives and NVMe tabs for the full list, form factors and current status.
What network speeds are supported?
Validated OCP and PCIe adapters cover 10GbE, 25GbE, 100GbE. Note whether a SKU includes optical modules; we can supply matched optics if required.
What power supplies are available?
The list runs from 900W to 3000W in platinum and titanium ratings. Redundant pairs can be configured for high availability; size the PSU to your CPU, GPU and drive load.
Which operating systems are certified?
The OS matrix lists 4 certified builds, including Red Hat Enterprise Linux, Rocky Linux, VMware ESXi, Windows Server, each with its exact kernel or build string. Additional builds can often be confirmed on request.
What do the lifecycle statuses mean?
Current/GA parts are in production; PILOT and DEVELOP parts are under limited rollout or qualification; EOM parts are out of marketing but supported as spares. Prefer Current parts for new builds.
Can you supply the server or just parts?
Both. We configure complete systems and supply every validated component listed here with warranty. Send a part list or BOM for a fast quotation.
serverbastion.com

WeChat
Scan the QR Code with wechat