The FusionServer Pro 2288 V8 is xFusion’s current-generation dual-socket 2U rack server, built on the Intel Xeon 6 platform. A single platform code line accepts two very different processor families: high-frequency Granite Rapids P-series cores for databases, virtualization and general compute, and high-density Sierra Forest E-series efficiency cores for scale-out and cloud-native workloads — up to 144 cores per socket on the E-series. Combined with DDR5 RDIMMs, PCIe 5.0 NVMe drives and a full set of validated RAID and network options, the 2288 V8 is the general-purpose flagship of the xFusion rack range.

Below is the verified compatibility matrix for this model: 259 validated line items across 11 component categories and 14 operating-system builds, taken from xFusion’s official compatibility data and translated to English. Every part number listed has been published by xFusion for this chassis — nothing here is guessed or cross-filled from other models.

Form factor2U dual-socket rack
CPU familiesGranite Rapids + Sierra Forest
Top core countUp to 144 cores / socket (E-series)
MemoryDDR5 RDIMM up to 128GB modules
StorageSAS / SATA & PCIe 5.0 NVMe
Validated items259 parts · 14 OS builds

What the compatibility matrix covers

Use the tabs below to browse validated parts by category. Each tab shows the number of listed items; within a category you can search by part number or keyword and expand the full list. Part status is marked as Current (actively orderable) or life-cycle / EOM (end of marketing, still supported and often available as spares). The operating-system table lists the exact release and kernel/build xFusion has certified.

P/NDescription / SpecificationStatus
4102Y199X86 series-FCLGA4710-2000MHz-1.6V/1.83V-64bit-350000mW-Granite Rapids-SP XCC CPU-Intel Xeon 6787P -86Core Current
4102Y200X86 series-FCLGA4710-2400MHz-1.6V/1.83V-64bit-350000mW-Granite Rapids-SP XCC CPU-Intel Xeon 6767P -64Core Current
4102Y201X86 series-FCLGA4710-2700MHz-1.6V/1.83V-64bit-330000mW-Granite Rapids-SP XCC CPU-Intel Xeon 6747P -48Core Current
4102Y202X86 series-FCLGA4710-2200MHz-1.6V/1.83V-64bit-330000mW-Granite Rapids-SP XCC CPU-Intel Xeon 6760P -64Core Current
4102Y203X86 series-FCLGA4710-2100MHz-1.6V/1.83V-64bit-270000mW-Granite Rapids-SP XCC CPU-Intel Xeon 6740P -48Core Current
4102Y205X86 series-FCLGA4710-2500MHz-1.6V/1.83V-64bit-250000mW-Granite Rapids-SP XCC CPU-Intel Xeon 6730P -32Core Current
4102Y206X86 series-FCLGA4710-2300MHz-1.6V/1.83V-64bit-225000mW-Granite Rapids-SP HCC CPU-Intel Xeon 6530P -32Core Current
4102Y207X86 series-FCLGA4710-2400MHz-1.6V/1.83V-64bit-210000mW-Granite Rapids-SP HCC CPU-Intel Xeon 6520P -24Core Current
4102Y209X86 series-FCLGA4710-2000MHz-1.6V/1.83V-64bit-205000mW-Granite Rapids-SP HCC CPU-Intel Xeon 6736P-36Core Current
4102Y210X86 series-FCLGA4710-3000MHz-1.6V/1.83V-64bit-255000mW-Granite Rapids-SP HCC CPU-Intel Xeon 6527P -24Core Current
4102Y211X86 series-FCLGA4710-2900MHz-1.6V/1.83V-64bit-270000mW-Granite Rapids-SP HCC CPU-Intel Xeon 6737P -32Core Current
4102Y212X86 series-FCLGA4710-3200MHz-1.6V/1.83V-64bit-190000mW-Granite Rapids-SP LCC CPU-Intel Xeon 6517P -16Core Current
4102Y213X86 series-FCLGA4710-3500MHz-1.6V/1.83V-64bit-150000mW-Granite Rapids-SP LCC CPU-Intel Xeon 6507P -8Core Current
4102Y214X86 series-FCLGA4710-2300MHz-1.6V/1.83V-64bit-150000mW-Granite Rapids-SP LCC CPU-Intel Xeon 6515P -16Core Current
4102Y215X86 series-FCLGA4710-2200MHz-1.6V/1.83V-64bit-150000mW-Granite Rapids-SP LCC CPU-Intel Xeon 6505P -12Core Current
4102Y217X86 series-FCLGA4710-1900MHz-1.6V/1.83V-64bit-250000mW-Sierra Forest-SP HDCC CPU-Intel Xeon 6766E -144Core Current
4102Y218X86 series-FCLGA4710-1800MHz-1.6V/1.83V-64bit-225000mW-Sierra Forest-SP HDCC CPU-Intel Xeon 6756E -128Core Current
4102Y219X86 series-FCLGA4710-2000MHz-1.6V/1.83V-64bit-250000mW-Sierra Forest-SP HDCC CPU-Intel Xeon 6746E -112Core Current
4102Y220X86 series-FCLGA4710-2400MHz-1.6V/1.83V-64bit-250000mW-Sierra Forest-SP HDCC CPU-Intel Xeon 6740E -96Core Current
4102Y221X86 series-FCLGA4710-2400MHz-1.6V/1.83V-64bit-205000mW-Sierra Forest-SP HDCC CPU-Intel Xeon 6710E -64Core Current
4102Y250X86 series-FCLGA4710-3600MHz-1.6V/1.83V-64bit-210000mW-Granite Rapids-SP LCC CPU-Intel Xeon 6724P -16Core Current
4102Y253X86 series-FCLGA4710-3100MHz-1.6V/1.83V-64bit-300000mW-Granite Rapids-SP XCC CPU-Intel Xeon 6745P -32Core Current
4102Y272X86 series-FCLGA4710-4000MHz-1.6V/1.83V-64bit-165000mW-Granite Rapids-SP LCC CPU-Intel Xeon 6714P -8Core Current
90010339Liquid Manufactory Auxiliaries,Thermal Grease,X-23-7868-2D,Thermal Conductivity 3.6W/mK / 6.0W/mK,2g,Gap filling thermal conductive for customer use,1ml Current
P/NDescription / SpecificationStatus
0251Y273memory module-2288H V7-generic memory-DDR5-RDIMM-64GB-288pin-0.312ns-6400000KHz-1.1V-ECC-2Rank(4G*4bit) Current
0251Y274memory module-2288H V7-generic memory-DDR5-RDIMM-32GB-288pin-0.312ns-6400000KHz-1.1V-ECC-2Rank(2G*8bit) Current
0251Y287memory module-2288H V7-M564R32-generic memory-DDR5-RDIMM-32GB-288pin-0.312ns-6400000KHz-1.1V-ECC-2Rank(2G*8bit)-overseas dedicated Current
0251Y288memory module-2288H V7-M564R64-generic memory-DDR5-RDIMM-64GB-288pin-0.312ns-6400000KHz-1.1V-ECC-2Rank(4G*4bit)-overseas dedicated Current
0251Y289memory module-2288H V7-M564R96-generic memory-DDR5-RDIMM-96GB-288pin-0.312ns-6400000KHz-1.1V-ECC-2Rank(6G*4bit)-3-way OEM code_overseas dedicated Current
0251Y290memory module-2288H V7-M564R128-generic memory-DDR5-RDIMM-128GB-288pin-0.312ns-6400000KHz-1.1V-ECC-2Rank(8G*4bit)-3-way OEM code_overseas dedicated Current
0251Y297memory module-2288H V7-M564R32-generic memory-DDR5-RDIMM-32GB-288pin-0.312ns-6400000KHz-1.1V-ECC-2Rank(2G*8bit)-Samsung 1bnm-Turin platform prohibited Current
0251Y304memory module-2288 V8-M556R64-generic memory-DDR5-RDIMM-64GB-288pin-0.312ns-6400000KHz-1.1V-ECC-2Rank(4G*4bit)-XH consumable virtual code-overseas dedicated Current
0251Y305memory module-2288 V8-M564R64-generic memory-DDR5-RDIMM-64GB-288pin-0.312ns-6400000KHz-1.1V-ECC-2Rank(4G*4bit)-XH consumable virtual code,Intel platform dedicated Current
0251Y306memory module-2288 V8-M564R32-generic memory-DDR5-RDIMM-32GB-288pin-0.312ns-6400000KHz-1.1V-ECC-2Rank(2G*8bit)-XH consumable virtual code-Intel platform dedicated Current
0251Y315memory module-2288H V7-M564R32-generic memory-DDR5-RDIMM-32GB-288pin-0.312ns-6400000KHz-1.1V-ECC-2Rank(2G*8bit)-Samsung 1bnm-Turin platform prohibited Current
0251Y317memory module-2288H V7-generic memory-DDR5-RDIMM-64GB-288pin-0.312ns-6400000KHz-1.1V-ECC-2Rank(4G*4bit) Current
0251Y321memory module-2288H V7-generic memory-DDR5-RDIMM-64GB-288pin-0.312ns-6400000KHz-1.1V-ECC-2Rank(4G*4bit) Current
0251Y325memory module-2288H V7-M564R32-generic memory-DDR5-RDIMM-32GB-288pin-0.312ns-6400000KHz-1.1V-ECC-2Rank(2G*8bit)-Samsung 1bnm-Turin platform prohibited Current
0251Y344memory module-2258 V7-M564R64-generic memory-DDR5-RDIMM-64GB-288pin-0.312ns-6400000KHz-1.1V-ECC-2Rank(4G*4bit)-Samsung 1bnm-Turin platform prohibited Current
0251Y348memory module-2288H V7-M564R96-generic memory-DDR5-RDIMM-96GB-288pin-0.312ns-6400000KHz-1.1V-ECC-2Rank(6G*4bit) Current
0251Y357memory module-2288H V7-M564R16-generic memory-DDR5-RDIMM-16GB-288pin-0.312ns-6400000KHz-1.1V-ECC-1Rank(2G*8bit) Current
0620Y029-020generic memory-DDR5-RDIMM-32GB-288pin-0.312ns-6400000KHz-1.1V-ECC-2Rank(2G*8bit)-Samsung 1bnm-Turin platform prohibited Current
0620Y031-029generic memory-DDR5-RDIMM-64GB-288pin-0.312ns-6400000KHz-1.1V-ECC-2Rank(4G*4bit)-Samsung 1bnm-Turin platform prohibited Current
0620Y032-A02generic memory-DDR5-RDIMM-96GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(6G*4bit)-SAMSUNG 1anm_M321RYGA0PB0-CWM_Sea Current
0620Y038generic memory-DDR5-RDIMM-16GB-288pin-0.312ns-6400000KHz-1.1V-ECC-1Rank(2G*8bit) Current
0620Y040generic memory-DDR5-RDIMM-32GB-288pin-0.312ns-6400000KHz-1.1V-ECC-2Rank(2G*8bit) Current
0620Y040-003generic memory-DDR5-RDIMM-32GB-288pin-0.312ns-6400000KHz-1.1V-ECC-2Rank(2G*8bit)-overseas dedicated Current
0620Y040-008generic memory-DDR5-RDIMM-32GB-288pin-0.312ns-6400000KHz-1.1V-ECC-2Rank(2G*8bit)-CXMT Current
0620Y042generic memory-DDR5-RDIMM-64GB-288pin-0.312ns-6400000KHz-1.1V-ECC-2Rank(4G*4bit) Current
0620Y042-003generic memory-DDR5-RDIMM-64GB-288pin-0.312ns-6400000KHz-1.1V-ECC-2Rank(4G*4bit)-Samsung 1bnm Current
0620Y042-006generic memory-DDR5-RDIMM-64GB-288pin-0.312ns-6400000KHz-1.1V-ECC-2Rank(4G*4bit)-overseas dedicated Current
0620Y042-011generic memory-DDR5-RDIMM-64GB-288pin-0.312ns-6400000KHz-1.1V-ECC-2Rank(4G*4bit)-CXMT Current
0620Y043generic memory-DDR5-RDIMM-96GB-288pin-0.312ns-6400000KHz-1.1V-ECC-2Rank(6G*4bit) Current
0620Y043-010generic memory-DDR5-RDIMM-96GB-288pin-0.312ns-6400000KHz-1.1V-ECC-2Rank(6G*4bit)-3-way OEM code_overseas dedicated Current
0620Y044generic memory-DDR5-RDIMM-256GB-288pin-0.312ns-6400000KHz-1.1V-ECC-4Rank(8G*4bit)-3DS Current
0620Y074generic memory-DDR5-MCRDIMM-64GB-288pin-0.227ns-8800000KHz-1.1V-ECC-2Rank(4G*4bit) Current
P/NDescription / SpecificationStatus
0254Y059generic drive module-Servers-generic drive-1200GB-SAS 12Gb/s-10000rpm-2.5inch-128MB and above-hot-swap-internal-2.5 inch bracket-V7 server dedicated Current
0254Y060generic drive module-Servers-generic drive-1200GB-SAS 12Gb/s-10000rpm-2.5inch-128MB and above-hot-swap-internal-3.5 inch bracket-V7 server dedicated Current
0254Y063generic drive module-Servers-generic drive-2400GB-SAS 12Gb/s-10000rpm-2.5inch-256MB-hot-swap-internal-2.5 inch bracket-V7 server dedicated Current
0254Y064generic drive module-Servers-generic drive-2400GB-SAS 12Gb/s-10000rpm-2.5inch-256MB-hot-swap-internal-3.5 inch bracket-V7 server dedicated Current
0254Y096generic drive module-Servers-generic drive-20TB-SATA 6.0Gb/s-7.2K rpm-3.5 inch-hot-swap-internal-3.5 inch bracket-V7 server dedicated Current
0254Y369generic drive module-Servers-generic drive-600GB-SAS 12Gb/s-10000rpm-2.5inch-128MB and above-hot-swap-internal-2.5 inch bracket-V7 server dedicated-Seagate dedicated Current
0254Y370generic drive module-Servers-generic drive-600GB-SAS 12Gb/s-10000rpm-2.5inch-128MB and above-hot-swap-internal-2.5 inch bracket-V7 server dedicated-Toshiba dedicated Current
0254Y470generic drive module-Servers-generic drive-8000GB-SATA 6.0Gb/s-7.2K rpm-3.5inch-128MB or above-hot-swap-internal-3.5 inch bracket-SEAGATE-V7 dedicated Current
0254Y691generic drive module-Servers-generic drive-20TB-SATA 6.0Gb/s-7.2K rpm-3.5 inch-hot-swap-internal-3.5 inch bracket-designated-model dedicated-Summit V7 server dedicated Current
0254Y693generic drive module-Servers-generic drive-16000GB-SATA 6.0Gb/s-7.2K rpm-3.5inch-256MB-hot-swap-internal-3.5 inch bracket-designated-model dedicated-Summit V7 server dedicated Current
0254Y700generic drive module-Servers-generic drive-600GB-SAS 12Gb/s-10000rpm-2.5inch-128MB and above-hot-swap-internal-3.5 inch bracket-V7 server dedicated-Seagate dedicated Current
0254Y702generic drive module-Servers-generic drive-600GB-SAS 12Gb/s-10000rpm-2.5inch-128MB and above-hot-swap-internal-3.5 inch bracket-V7 server dedicated-Toshiba dedicated Current
0254Y848generic drive module-Servers-generic drive-16000GB-SATA 6.0Gb/s-7.2K rpm-3.5inch-256MB-hot-swap-internal-3.5 inch bracket-WDC-Paris CP-V7 dedicated Current
0254Y849generic drive module-Servers-generic drive-16000GB-SATA 6.0Gb/s-7.2K rpm-3.5inch-256MB-hot-swap-internal-3.5 inch bracket-Toshiba-MG09-V7 dedicated Current
0254Y850generic drive module-Servers-generic drive-20000GB-SATA 6.0Gb/s-7.2K rpm-256MB-3.5 inch-hot-swap-internal-3.5 inch bracket-WDC-Paris CP-V7 dedicated Current
0254Y851generic drive module-Servers-generic drive-8000GB-SATA 6.0Gb/s-7.2K rpm-3.5inch-128MB or above-hot-swap-internal-3.5 inch bracket-Toshiba MG10Air-V7 dedicated Current
0254Y852generic drive module-Servers-generic drive-8000GB-SATA 6.0Gb/s-7.2K rpm-3.5inch-256MB-hot-swap-internal-3.5 inch bracket-WDC Vela-A1-V7 dedicated Current
0254Y888generic drive module-Servers-generic drive-20000GB-NL SAS 12Gb/s-7200rpm-3.5inch-256MB-hot-swap-internal-3.5 inch bracket-Seagate Summit V7 server dedicated Current
0255Y347SSD module-Servers-SSD-1920GB-SATA 6Gb/s-mixed read-write-PM897 series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255Y417SSD module-Servers-SSD-480GB-SATA 6Gb/s-read-intensive-PM893 series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255Y418SSD module-Servers-SSD-480GB-SATA 6Gb/s-read-intensive-PM893 series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255Y419SSD module-Servers-SSD-960GB-SATA 6Gb/s-read-intensive-PM893 series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255Y420SSD module-Servers-SSD-960GB-SATA 6Gb/s-read-intensive-PM893 series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255Y421SSD module-Servers-SSD-1920GB-SATA 6Gb/s-read-intensive-PM893 series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255Y422SSD module-Servers-SSD-1920GB-SATA 6Gb/s-read-intensive-PM893 series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255Y423SSD module-Servers-SSD-3840GB-SATA 6Gb/s-read-intensive-PM893 series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255Y424SSD module-Servers-SSD-3840GB-SATA 6Gb/s-read-intensive-PM893 series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255Y427SSD module-Servers-SSD-480GB-SATA 6Gb/s-mixed read-write-PM897 series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255Y428SSD module-Servers-SSD-480GB-SATA 6Gb/s-mixed read-write-PM897 series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255Y429SSD module-Servers-SSD-960GB-SATA 6Gb/s-mixed read-write-PM897 series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255Y430SSD module-Servers-SSD-960GB-SATA 6Gb/s-mixed read-write-PM897 series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255Y431SSD module-Servers-SSD-1920GB-SATA 6Gb/s-mixed read-write-PM897 series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255Y432SSD module-Servers-SSD-3840GB-SATA 6Gb/s-mixed read-write-PM897 series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255Y433SSD module-Servers-SSD-3840GB-SATA 6Gb/s-mixed read-write-PM897 series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255YDUHSSD module-Servers-SSD-480GB-SATA 6Gb/s-read-intensive-SE006 series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255YDUJSSD module-Servers-SSD-480GB-SATA 6Gb/s-read-intensive-SE006 series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255YDUMSSD module-Servers-SSD-960GB-SATA 6Gb/s-read-intensive-SE006 series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255YDUNSSD module-Servers-SSD-960GB-SATA 6Gb/s-read-intensive-SE006 series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255YDURSSD module-Servers-SSD-1920GB-SATA 6Gb/s-read-intensive-SE006 series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255YDUSSSD module-Servers-SSD-1920GB-SATA 6Gb/s-read-intensive-SE006 series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255YDXASSD module-Servers-SSD-3840GB-SATA 6Gb/s-read-intensive-SE006 series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255YDXBSSD module-Servers-SSD-3840GB-SATA 6Gb/s-read-intensive-SE006 series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255YESSSSD module-Servers-SSD-3840GB-SATA 6Gb/s-read-intensive-PM893 series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255YESTSSD module-Servers-SSD-3840GB-SATA 6Gb/s-read-intensive-PM893 series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255YETESSD module-Servers-SSD-480GB-SATA 6Gb/s-read-intensive-SE006 series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255YETJSSD module-Servers-SSD-480GB-SATA 6Gb/s-read-intensive-SE006 series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255YEUNSSD module-Servers-SSD-480GB-SATA 6Gb/s-read-intensive-PM893 series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255YEURSSD module-Servers-SSD-480GB-SATA 6Gb/s-read-intensive-PM893 series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255YEXFSSD module-Servers-SSD-1920GB-SATA 6Gb/s-read-intensive-SE006 series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255YEXMSSD module-Servers-SSD-1920GB-SATA 6Gb/s-read-intensive-SE006 series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255YEXQSSD module-Servers-SSD-1920GB-SATA 6Gb/s-read-intensive-PM893 series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255YEXRSSD module-Servers-SSD-3840GB-SATA 6Gb/s-read-intensive-SE006 series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255YEXTSSD module-Servers-SSD-1920GB-SATA 6Gb/s-read-intensive-PM893 series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255YEXWSSD module-Servers-SSD-3840GB-SATA 6Gb/s-read-intensive-SE006 series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255YEYPSSD module-Servers-SSD-960GB-SATA 6Gb/s-read-intensive-SE006 series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255YEYTSSD module-Servers-SSD-960GB-SATA 6Gb/s-read-intensive-SE006 series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255YFAFSSD module-Servers-SSD-1920GB-SATA 6Gb/s-mixed read-write-PM897 series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255YFBDSSD module-Servers-SSD-960GB-SATA 6Gb/s-read-intensive-PM893 series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255YFBESSD module-Servers-SSD-960GB-SATA 6Gb/s-read-intensive-PM893 series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0254Y058Hard Disk Module,Servers,Hard Disk,600GB,SAS 12Gb/s,10000rpm,2.5inch,128MB or above,Hot_plug,Built-in,3.5 inch Front Panel,V7 server dedicated Current Field replaceable
0255YBARSSD Module,Servers,SSD,3840GB,NVMe PCIe,Read Intensive,PE321 Series,2.5inch(3.5inch Drive Bay),V7 dedicated Current Field replaceable
0255YBAQSSD Module,Servers,SSD,3840GB,NVMe PCIe,Read Intensive,PE321 Series,2.5inch(2.5inch Drive Bay),V7 dedicated Current Field replaceable
0254Y057Hard Disk Module,Servers,Hard Disk,600GB,SAS 12Gb/s,10000rpm,2.5inch,128MB or above,Hot_plug,Built-in,2.5 inch Front Panel,V7 server dedicated Current Field replaceable
0255YEGFSSD Module,Servers,SSD,3840GB,PCIE 5.0 X4,NVMe PCIe,Read Intensive,R6101 Series,2.5inch(2.5inch Drive Bay),V7 dedicated Current Field replaceable
0255YDXVSSD Module,Servers,SSD,7680GB,PCIE 5.0 X4,NVMe PCIe,Read Intensive,R6101 Series,2.5inch(2.5inch Drive Bay),V7 dedicated Current Field replaceable
0255YBASSSD Module,Servers,SSD,7680GB,NVMe PCIe,Read Intensive,PE321 Series,2.5inch(2.5inch Drive Bay),V7 dedicated Current Field replaceable
0255YBANSSD Module,Servers,SSD,1920GB,NVMe PCIe,Read Intensive,PE321 Series,2.5inch(2.5inch Drive Bay),V7 dedicated Current Field replaceable
0255YEBPSSD Module,Servers,SSD,6400GB,NVMe PCIe 5.0 X4,Mixed Use,R6301 Series,2.5inch(2.5inch Drive Bay),V7 Dedicated Current Field replaceable
0255YEBNSSD Module,Servers,SSD,6400GB,NVMe PCIe 5.0 X4,Mixed Use,R6301 Series,2.5inch(3.5inch Drive Bay),V7 Dedicated Current Field replaceable
0255YDXWSSD Module,Servers,SSD,7680GB,PCIE 5.0 X4,NVMe PCIe,Read Intensive,R6101 Series,2.5inch(3.5inch Drive Bay),V7 dedicated Current Field replaceable
0255YBATSSD Module,Servers,SSD,7680GB,NVMe PCIe,Read Intensive,PE321 Series,2.5inch(3.5inch Drive Bay),V7 dedicated Current Field replaceable
0255YBAPSSD Module,Servers,SSD,1920GB,NVMe PCIe,Read Intensive,PE321 Series,2.5inch(3.5inch Drive Bay),V7 dedicated Current Field replaceable
0255YEDMSSD Module,Servers,SSD,12800GB,PCIE 5.0 X4,NVMe PCIe,Mixed Use,R6301 Series,2.5inch(2.5inch Drive Bay),V7 dedicated Current Field replaceable
0255YCTYSSD Module,Servers,SSD,6400GB,PCIE 5.0 X4-Vendor ID 203F-Device ID 1100,2.5 inches 15mm,Read intensive,SP630 series,NVMe SSD Top-Level,2.5 inch (3.5inch Drive Bay),V7 dedicated Current Field replaceable
0255YCUESSD Module,Servers,SSD,7680GB,PCIE 5.0 X4-Vendor ID 203F-Device ID 1100,2.5 inches 15mm,Read intensive,SP530 series,NVMe SSD Top-Level,2.5 inch (2.5inch Drive Bay),V7 dedicated Current Field replaceable
0255YFFSSSD Module,Servers,SSD,15360GB,PCIE 5.0 X4,Read Intensive,R6101 Series,2.5inch(3.5inch Drive Bay),NVMe SSD,V7dedicated Current Field replaceable
0255YCUASSD Module,Servers,SSD,7680GB,PCIE 5.0 X4-Vendor ID 203F-Device ID 1100,2.5 inches 15mm,Read intensive,SP530 series,NVMe SSD Top-Level,2.5 inch (3.5inch Drive Bay),V7 dedicated Current Field replaceable
0255YEDNSSD Module,Servers,SSD,12800GB,PCIE 5.0 X4,NVMe PCIe,Mixed Use,R6301 Series,2.5inch(3.5inch Drive Bay),V7 dedicated Current Field replaceable
0255YCUDSSD Module,Servers,SSD,6400GB,PCIE 5.0 X4-Vendor ID 203F-Device ID 1100,2.5inch 15mm,Mixed use,SP630 Series,NVMe SSD Top-Level,2.5 inch (2.5inch Drive Bay),V7 dedicated Current Field replaceable
0255YDJDSSD Module,Servers,SSD,3840GB,PCIE 5.0 X4-Vendor ID 203F-Device ID 1100,2.5 inches 15mm,Read intensive,SP530 series,NVMe SSD Top-Level,2.5 inch (3.5inch Drive Bay),V7 dedicated Current Field replaceable
0255YDJCSSD Module,Servers,SSD,3840GB,PCIE 5.0 X4-Vendor ID 203F-Device ID 1100,2.5 inches 15mm,Read intensive,SP530 series,NVMe SSD Top-Level,2.5 inch (2.5inch Drive Bay),V7 dedicated Current Field replaceable
0255YDJFSSD Module,Servers,SSD,1920GB-PCIE 5.0 X4-Vendor ID 203F-Device ID 1100,2.5 inches 15mm,Read intensive,SP530 series,NVMe SSD Top-Level,2.5 inch (3.5inch Drive Bay),V7 dedicated Current Field replaceable
0255YDJESSD Module,Servers,SSD,1920GB-PCIE 5.0 X4-Vendor ID 203F-Device ID 1100,2.5 inches 15mm,Read intensive,SP530 series,NVMe SSD Top-Level,2.5 inch (2.5inch Drive Bay),V7 dedicated Current Field replaceable
0255YDJHSSD Module,Servers,SSD,3200GB,PCIE 5.0 X4-Vendor ID 203F-Device ID 1100,2.5inch 15mm,Mixed use,SP630 Series,NVMe SSD Top-Level,2.5 inch (3.5inch Drive Bay),V7 dedicated Current Field replaceable
0255YDJGSSD Module,Servers,SSD,3200GB,PCIE 5.0 X4-Vendor ID 203F-Device ID 1100,2.5inch 15mm,Mixed use,SP630 Series,NVMe SSD Top-Level,2.5 inch (2.5inch Drive Bay),V7 dedicated Current Field replaceable
0255YEGJSSD Module,Servers,SSD,3200GB,NVMe PCIe 5.0 X4,Mixed Use,R6301 Series,2.5inch(3.5inch Drive Bay),V7 Dedicated Current Field replaceable
0255YDQESSD Module,Servers,SSD,1600GB,PCIE 5.0 X4-Vendor ID 203F-Device ID 1100,2.5inch 15mm,Mixed use,SP630 Series,NVMe SSD Top-Level,2.5 inch (2.5inch Drive Bay),V7 dedicated Current Field replaceable
0255YEGHSSD Module,Servers,SSD,3200GB,NVMe PCIe 5.0 X4,Mixed Use,R6301 Series,2.5inch(2.5inch Drive Bay),V7 Dedicated Current Field replaceable
0255YEGGSSD Module,Servers,SSD,3840GB,PCIE 5.0 X4,NVMe PCIe,Read Intensive,R6101 Series,2.5inch(3.5inch Drive Bay),V7 dedicated Current Field replaceable
0255YFHJSSD Module,Servers,SSD,7680GB,PCIE 5.0 X4,Vendor ID 144D,Device ID A80E,Sub VID 144D-Sub DID AD05,E3.S 7.5mm,Read intensive,PM9D3a Series,NVMe SSD,V8 dedicated Current Field replaceable
0255YFHKSSD Module,Servers,SSD,3840GB,PCIE 5.0 X4,Vendor ID 144D,Device ID A900,Sub VID 144D,Sub DID AD04,E3.S 7.5mm,Read intensive,PM9D3a Series,NVMe SSD,V8 dedicated Current Field replaceable
0255YENESSD Module,Servers,SSD,15360GB,PCIE 5.0 X4-Vendor ID 1E3B-Device ID 0800,RI,R6101 Series,2.5inch(2.5inch Drive Bay),NVMe SSD,V7dedicated Current Field replaceable
P/NDescription / SpecificationStatus
0255YCEV-006SSD module-Servers-SSD-3840GB-PCIE 5.0 X4-NVMe PCIe-read-intensive-PM9D3a series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255YCEW-006SSD module-Servers-SSD-3840GB-PCIE 5.0 X4-NVMe PCIe-read-intensive-PM9D3a series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255YCEX-007SSD module-Servers-SSD-7680GB-PCIE 5.0 X4-NVMe PCIe-read-intensive-PM9D3a series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255YCEY-005SSD module-Servers-SSD-7680GB-PCIE 5.0 X4-NVMe PCIe-read-intensive-PM9D3a series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255YCFQ-003SSD module-Servers-SSD-1920GB-PCIE 5.0 X4-NVMe PCIe-read-intensive-PM9D3a series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255YCFR-004SSD module-Servers-SSD-1920GB-PCIE 5.0 X4-NVMe PCIe-read-intensive-PM9D3a series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255YCUASSD module-Servers-SSD-7680GB-PCIE 5.0 X4-Vendor ID 203F-Device ID 1100-2.5inch 15mm-read-intensive-SP530 series-NVMe SSD Top-Level-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255YCUESSD module-Servers-SSD-7680GB-PCIE 5.0 X4-Vendor ID 203F-Device ID 1100-2.5inch 15mm-read-intensive-SP530 series-NVMe SSD Top-Level-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255YDJCSSD module-Servers-SSD-3840GB-PCIE 5.0 X4-Vendor ID 203F-Device ID 1100-2.5inch 15mm-read-intensive-SP530 series-NVMe SSD Top-Level-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255YDJDSSD module-Servers-SSD-3840GB-PCIE 5.0 X4-Vendor ID 203F-Device ID 1100-2.5inch 15mm-read-intensive-SP530 series-NVMe SSD Top-Level-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255YDJESSD module-Servers-SSD-1920GB-PCIE 5.0 X4-Vendor ID 203F-Device ID 1100-2.5inch 15mm-read-intensive-SP530 series-NVMe SSD Top-Level-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255YDJFSSD module-Servers-SSD-1920GB-PCIE 5.0 X4-Vendor ID 203F-Device ID 1100-2.5inch 15mm-read-intensive-SP530 series-NVMe SSD Top-Level-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255YDXVSSD module-Servers-SSD-7680GB-PCIE 5.0 X4-NVMe PCIe-read-intensive-R6101 series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255YDXWSSD module-Servers-SSD-7680GB-PCIE 5.0 X4-NVMe PCIe-read-intensive-R6101 series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255YEBNSSD module-Servers-SSD-6400GB-NVMe PCIe 5.0 X4-mixed read-write-R6301 series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255YEBPSSD module-Servers-SSD-6400GB-NVMe PCIe 5.0 X4-mixed read-write-R6301 series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255YEDMSSD module-Servers-SSD-12800GB-PCIE 5.0 X4-NVMe PCIe-mixed read-write-R6301 series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255YEDNSSD module-Servers-SSD-12800GB-PCIE 5.0 X4-NVMe PCIe-mixed read-write-R6301 series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255YEGFSSD module-Servers-SSD-3840GB-PCIE 5.0 X4-NVMe PCIe-read-intensive-R6101 series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255YEGGSSD module-Servers-SSD-3840GB-PCIE 5.0 X4-NVMe PCIe-read-intensive-R6101 series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255YEGHSSD module-Servers-SSD-3200GB-NVMe PCIe 5.0 X4-mixed read-write-R6301 series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255YEGJSSD module-Servers-SSD-3200GB-NVMe PCIe 5.0 X4-mixed read-write-R6301 series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255YENESSD module-Servers-SSD-15360GB-PCIE 5.0 X4-read-intensive-R6101 series-2.5 inch(2.5 inch bracket)-NVMe SSD-V7 dedicated Current
0255YESKSSD module-Servers-SSD-7680GB-PCIE 5.0 X4-NVMe PCIe-read-intensive-PM9D3a series-2.5 inch(3.5 inch bracket)-V7 dedicated Current
0255YESMSSD module-Servers-SSD-7680GB-PCIE 5.0 X4-NVMe PCIe-read-intensive-PM9D3a series-2.5 inch(2.5 inch bracket)-V7 dedicated Current
0255YFFSSSD module-Servers-SSD-15360GB-PCIE 5.0 X4-read-intensive-R6101 series-2.5 inch(3.5 inch bracket)-NVMe SSD-V7 dedicated Current
0255YFHJSSD module-Servers-SSD-7680GB-PCIE 5.0 X4-Vendor ID 144D-Device ID A80E-Sub VID 144D-Sub DID AD05-E3.S 7.5mm-read-intensive-PM9D3a series-NVMe SSD-V8 dedicated Current
0255YFHKSSD module-Servers-SSD-3840GB-PCIE 5.0 X4-Vendor ID 144D-Device ID A900-Sub VID 144D-Sub DID AD04-E3.S 7.5mm-read-intensive-PM9D3a series-NVMe SSD-V8 dedicated Current
0255YCUYSSD Module,Servers,M.2 SSD,NVMe PCIe,480GB,80.0mm * 22.0mm * 3.58 mm(Non-hot-swappable),PM9A3 series Current Field replaceable
0255Y696SSD Module,Servers,M.2 SSD,SATA 6Gb/s-240GB,80.0mm * 22.0mm * 3.58 mm(Non-hot-swappable),ER3 series Current Field replaceable
0255Y698SSD Module,Servers,M.2 SSD,SATA 6Gb/s-480GB,80.0mm * 22.0mm * 3.58 mm(Non-hot-swappable),ER3 series Current Field replaceable
0255YCULSSD Module,Servers,M.2 SSD,NVMe PCIe,960GB,80.0mm * 22.0mm * 3.58 mm(Non-hot-swappable),PJ1 series Current Field replaceable
0255Y697SSD Module,Servers,M.2 SSD,SATA 6Gb/s-480GB,80.0mm * 22.0mm * 3.58 mm(hot-swappable),ER3 series Current Field replaceable
0255Y695SSD Module,Servers,M.2 SSD,SATA 6Gb/s-240GB,80.0mm * 22.0mm * 3.58 mm(hot-swappable),ER3 series Current Field replaceable
0255YCTNSSD Module,Servers,M.2 SSD,NVMe PCIe,960GB,110.0mm * 22.0mm * 3.8 mm(Non-hot-swappable),PM9A3 series Current Field replaceable
0255Y928SSD Module,Servers,M.2 SSD,NVMe PCIe,1920GB,110.0mm * 22.0mm * 3.58 mm(Non-hot-swappable),PM9A3 series Current Field replaceable
P/NDescription / SpecificationStatus
02312FLQfunction module-2288H V5-BC1SPSCA11-INTEL VROC KEY,advanced edition,supports RAID 0/1/10/5 Current
02312FLRfunction module-2288H V5-BC1SPSCA12-INTEL VROC KEY,standard edition,supports RAID 0/1/10 Current
0231Y131function module-9560-16i 8G-CN2M956016I8G-9560-16i 8G other board card-12G SAS RAID card-8G cache-16*12Gb/s SAS PHY-2 slimline internal interface-PCIE 4.0 X8-Vendor ID 1000-Device ID 10E2-Subvendor ID 1000-Subdevice ID 4000 Current
0231Y735function module-9540-8i-CN2M95408I-PCIE 4.0 X8-Vendor ID 1000-Device ID 10E6-1-Subvendor ID 1000-Subdevice ID 40D5-12G SAS RAID-9540-8i-x8 PCIe 4.0-9540-8i SAS RAID Card,SAS3808,No CacheVault,12Gb/s SAS,6Gb/s SATA,PCIe(NVMe)-9540-8i Current
0231Y736function module-9540-16i-CN2M954016I-PCIE 4.0 X8-Vendor ID 1000-Device ID 10E6-1-Subvendor ID 1000-Subdevice ID 40D0-12G SAS RAID-x8 PCIe 4.0-9540-16i SAS RAID Card,SAS3816,No CacheVault,12Gb/s SAS,6Gb/s SATA,PCIe(NVMe)-9540-16i Current
0256Y064RAID card module-Public Module-BC5M01RLAH1-XP270-M2-(SAS3808-BootCard)-M.2 RAID standardcard-RAID0,1,JBOD-No Cache-supports sideband management-half-height half-length-full-height bracket-PCIe 4.0 x8 Current
0256Y066RAID card module-Public Module-BC5M02RLAH1-XP270-M2-(SAS3808-BootCard)-M.2 RAID standardcard-RAID0,1,JBOD-No Cache-supports sideband management-half-height half-length-half-height bracket-PCIe 4.0 x8 Current
0256Y113RAID card module-2288 V8-BC5M01RLAEG-XC170-M-8i-(SAS3808iMR)-SAS/SATA RAID cable card-RAID0,1,10-12Gb/s-no Cache-supports sideband management(2U air-shroud mounting) Current
0256Y117RAID card module-2288 V8-BC16M02RLAEG-XC170-M-8i-(SAS3808iMR)-SAS/SATA RAID cable card-RAID0,1,10-12Gb/s-no Cache-supports sideband management(2U bracket mounting) Current
0256Y122RAID card module-2288 V8-BC16M02RLADB-XC470C-M-16i 4G-(SAS3916)-RAID cable card-RAID0,1,5,6,10,50,60-12Gb/s-4GB Cache-supports supercap & sideband management(2U bracket mounting) Current
0256Y123RAID card module-2288 V8-BC16M01RLADB-XC470C-M-16i 4G-(SAS3916)-RAID cable card-RAID0,1,5,6,10,50,60-12Gb/s-4GB Cache-supports supercap & sideband management(2U air-shroud mounting) Current
0256Y124RAID card module-2288 V8-BC16M02RLAD-XC470C-M-8i 4G-(SAS3908)-RAID cable card-RAID0,1,5,6,10,50,60-12Gb/s-4GB Cache-supports supercap & sideband management(2U bracket mounting) Current
0256Y125RAID card module-2288 V8-BC16M01RLAD-XC470C-M-8i 4G-(SAS3908)-RAID cable card-RAID0,1,5,6,10,50,60-12Gb/s-4GB Cache-supports supercap & sideband management(2U air-shroud mounting) Current
0256Y132RAID card module-2288 V8-BC16M04RLAEG-XC170-M-8i-(SAS3808iMR)-SAS/SATA RAID cable card-RAID0,1,10-12Gb/s-no Cache-supports sideband management(2U IO1 Riser mounting) Current
0256Y134RAID card module-2288 V8-BC16M04RLADB-XC470C-M-16i 4G-(SAS3916)-RAID cable card-RAID0,1,5,6,10,50,60-12Gb/s-4GB Cache-supports supercap & sideband management(2U IO1 Riser mounting) Current
0256Y135RAID card module-2288 V8-BC16M04RLAD-XC470C-M-8i 4G-(SAS3908)-RAID cable card-RAID0,1,5,6,10,50,60-12Gb/s-4GB Cache-supports supercap & sideband management(2U IO1 Riser mounting) Current
0256Y163RAID card module-2288 V8-BC16M01RLAEC-XC370-M-16i-(SAS3816IT)-SAS/SATA RAID cable card-None RAID-12Gb/s-no Cache-supports sideband management(2U air-shroud mounting) Current
0256Y164RAID card module-2288 V8-BC16M02RLAEC-XC370-M-16i-(SAS3816IT)-SAS/SATA RAID cable card-None RAID-12Gb/s-no Cache-supports sideband management(2U bracket mounting) Current
0256Y166RAID card module-2288 V8-BC16M04RLAEC-XC370-M-16i-(SAS3816IT)-SAS/SATA RAID cable card-None RAID-12Gb/s-no Cache-supports sideband management(2U IO1 Riser mounting) Current
0256Y174RAID card module-2288H V7-9560-8i 4G-12G SAS RAID card-9560-8i-(SAS3908)-CVPM05-12Gb/s SAS-6Gb/s SATA-PCIe(NVMe)-4G CacheVault-PCIE 4.0 X8-Vendor ID 1000-Device ID 10E2-Subvendor ID 1000-Subdevice ID 4010 Current
0256Y179RAID card module-2288H V7-9560-16i 8G-12G SAS RAID card-9560-16i-(SAS3916)-CVPM05-12Gb/s SAS,6Gb/s SATA,PCIe(NVMe)-8G CacheVault-PCIE 4.0 X8-Vendor ID 1000-Device ID 10E2-Subvendor ID 1000-Subdevice ID 4000 Current
0256Y186RAID card module-2288 V8-BC16M07RLAEG-XC170-M-8i-(SAS3808iMR)-SAS/SATA RAID cable card-RAID0,1,10-12Gb/s-no Cache-supports sideband management(4GPU tray mounting) Current
0256Y187RAID card module-2288 V8-BC16M07RLAD-XC470C-M-8i 4G-(SAS3908)-RAID cable card-RAID0,1,5,6,10,50,60-12Gb/s-4GB Cache-supports supercap & sideband management(4GPU tray mounting) Current
0256Y204RAID card module-2288 V8-Dapustor F6100-PCIE 4.0 X4-Vendor ID 1e3b-Device ID 50b1-1-Subvendor ID 1e3b-Subdevice ID 50b1-PCIE 4.0 X4-Dapustor F6100 RAID Card-DP808AL-6Gb/s SATA,PCIE5.0 X2 NVMe-Chinese documentation-withthermal pad Current
0231Y129function module-9560-8i 4G-CN2M95608I4G-9560-8i 4G other board card-12G SAS RAID card-4G cache-8*12Gb/s SAS PHY-1 slimline internal interface-PCIE 4.0 X8-Vendor ID 1000-Device ID 10E2-Subvendor ID 1000-Subdevice ID 4010 EOM
0817Y002Super capacitor module,64mm*51mm*13.1mm,Wire mounting,split from 08170002,NA,7600uF,5h Current Field replaceable
0302Y201Manufactured Board-JDM,Public Module,BC55RLAD,XC470C-M-8i 4G-(SAS3908)-RAID Cable Card-RAID0,1,5,6,10,50,60-12Gb/s-4GB Cache,Capacitor and Management,PCIE 4.0 X8-Vendor ID 1000-Device ID 10E2-1-Subvendor ID 1F24-Subdevice ID 3000,1*1 Current Field replaceable
0302Y204Manufactured Board-JDM,Public Module,BC56RLAE,XC170-M-8i-(SAS3808iMR)-SAS/SATA RAID Cable Card-RAID0,1,10-12Gb/s-no Cache,Support Sideband Management,PCIE 4.0 X8-Vendor ID 1000-Device ID 10E6-1-Subvendor ID 1F24-Subdevice ID 3002,1*1 Current Field replaceable
0256Y025RAID Card Module,2288H V6,9500-8e,PCIE 4.0 X8-Vendor ID 1000-Device ID 00E6-1-Subvendor ID 1000-Subdevice ID 4080-12G SAS RAID-x8 PCIe 4.0-9500-8e SAS RAID Card,SAS3808,No CacheVault,12Gb/s SAS,6Gb/s SATA,PCIe(NVMe)-9500-8e Current Field replaceable
0302Y203Manufactured Board-JDM,Public Module,BC55RLADB,XC470C-M-16i 4G-(SAS3916)-RAID Cable Card-RAID0,1,5,6,10,50,60-12Gb/s-4GB Cache, Capacitor and Management,PCIE 4.0 X8-Vendor ID 1000-Device ID 10E2-1-Subvendor ID 1F24-Subdevice ID 3001,1*1 Current Field replaceable
0256Y144RAID Card Module,2288H V7,9520-2M2,PCIe 4.0 x8,M.2 RAID Card,SAS3808,No CacheVault,6Gb/s SATA,12Gb/s SAS,16GT/s PCIe Gen4(NVMe),Vendor ID 1000-Device ID 10E6-1-Subvendor ID 1000-Subdevice ID 40DA Current Field replaceable
0256Y106RAID Card Module,2288H V7,Dapustor F6100,PCIE 4.0 X4-Vendor ID 1e3b-Device ID 50b1-1-Subvendor ID 1e3b-Subdevice ID 50b1,PCIE 4.0 X4-Dapustor F6100 RAID Card-DP808AL-6Gb/s SATA,PCIE5.0 X2 NVMe Current Field replaceable
0231Y752Function Module,9580-8i8e,CN2M95808I8E,PCIe 4.0 x8-9580-8i8e SAS RAID Card,SAS3916, 8G CacheVault,CVPM05-12Gb/s SAS,6Gb/s SATA,PCIe(NVMe)-9580-8i8e,Comes with 1pcs short flap Current Field replaceable
0302Y207Manufactured Board-JDM,Public Module,BC56RLAEC,XC370-M-16i-(SAS3816IT)-SAS/SATA RAID Cable Card-None RAID-12Gb/s-no Cache,Support Sideband Management,PCIE 4.0 X8-Vendor ID 1000-Device ID 00E6-1-Subvendor ID 1F24-Subdevice ID 3007,1*1 Current Field replaceable
0302Y863Manufactured Board,2288 V8,BC16HBMA,16Port Cable SATA Controller Card,2*2 Current Field replaceable
0302Y976Manufactured Board,2288 V8,BC16HBMAA,8Port Cable SATA Controller Card,2*2 Current Field replaceable
0256Y069RAID Card Module,Public Module,9540-2M2,Vendor ID 1000-Device ID 10E6-1-Subvendor ID 1000-Subdevice ID 40E0-12G SAS RAID card,x8 PCIe 4.0-9540-2M2 SAS RAID Card,SAS3808,No CacheVault,12Gb/s SAS,6Gb/s SATA,PCIe(NVMe) Current Field replaceable
P/NDescription / SpecificationStatus
0231Y752function module-9580-8i8e-CN2M95808I8E-PCIe 4.0 x8-9580-8i8e SAS RAID Card,SAS3916,8G CacheVault,CVPM05-12Gb/s SAS,6Gb/s SATA,PCIe(NVMe)-9580-8i8e-included 1pcs low-profile bracket Current
0231Y803function module-Servers-CN2M01ITGBA1-XP210 Intel I350 2*GE+half-height half-length(incl. half-height & full-height brackets)standard network adapter-PCIE 2.0 X4-Vendor ID 8086-Device ID 1521-2 Current
0231Y804function module-Servers-CN2M01ITGC1-XP212 Intel I350 4*GE+half-height half-length(incl. half-height & full-height brackets)standard network adapter-PCIE 2.0 X4-Vendor ID 8086-Device ID 1521-4 Current
0231Y809function module-Servers-CN2M04ITGG1-XP330 Ethernet adapter-10Gb optical port(Intel X710)-dual-port-SFP+(optical module not included)-half-height half-length(incl. half-height & full-height brackets)-PCIe 3.0 x8 Current
0231Y812function module-Servers-CN2M03ITGH1-XP332 Ethernet adapter-10Gb optical port(Intel XL710)-quad-port-SFP+(optical module not included)-half-height half-length(incl. half-height & full-height brackets)-PCIe 3.0 x8 Current
0231Y829function module-Servers-CN2M06ITGG1-XP330 Ethernet adapter-10Gb optical port(Intel X710)-dual-port-SFP+(incl. 2 optical modules)-half-height half-length(incl. half-height & full-height brackets)-PCIe 3.0 x8(domestic & overseas) Current
0231Y830function module-Servers-CN2M05ITGH1-XP332 Ethernet adapter-10Gb optical port(Intel XL710)-quad-port-SFP(incl. 4 optical modules)-half-height half-length(incl. half-height & full-height brackets)-PCIe 3.0 x8(domestic & overseas) Current
0231YAFQfunction module-Public Module-BCM957414A4142CC-function module-Fourier-BCM957414A4142CC-network adapter-25Gb optical port(BCM957414A4142CC)-dual-port-SFP28(incl. 2 optical modules)-PCIE 3.0 x8-14e4-16d7-2(domestic & overseas) Current
0256Y025RAID card module-2288H V6-9500-8e-PCIE 4.0 X8-Vendor ID 1000-Device ID 00E6-1-Subvendor ID 1000-Subdevice ID 4080-12G SAS RAID-x8 PCIe 4.0-9500-8e SAS RAID Card,SAS3808,No CacheVault,12Gb/s SAS,6Gb/s SATA,PCIe(NVMe)-9500-8e Current
0257Y099PCIe-network adapter-2288H V6-E810XXVDA2G1P5-network adapter-25G optical port(E810XXVDA2G1P5 978333)-dual-port-SFP28(optical module not included)-PCIE 4.0 X8-8086-159b|0003-2-with driver package Current
0257Y101PCIe-network adapter-2288H V6-E810CQDA2-network adapter-100G optical port(E810CQDA2G2P5 99A454)-dual-port-QSFP28(optical module not included)-PCIE 4.0 X16-8086-1592|0002-2-with driver package Current
0257Y102PCIe-network adapter-2288H V6-MCX631102AN-ADAT-network adapter-25 GE-64bit-SFP28-2-PCIE 4.0 x8-15b3-101f-2-with driver package Current
0257Y110PCIe-network adapter-2288H V6-LPe31002-AP-Emulex -FC HBA card-16Gb/s(LPe31002)-dual-port-SFP+(incl. 2 multimode optical modules)-PCIE 3.0 x8-Vendor ID 10DF-Device ID E300-2-Subvendor ID 10DF-Subdevice ID E310-with driver package Current
0257Y116PCIe-network adapter-2288H V6-X710T2L-10Gb/s-64bit-10GBASE-T-2 ports-PCIE 3.0 x8-8086-15ff-2-with driver package Current
0257Y117PCIe-network adapter-2288H V6-E810XXVDA4-network adapter-25G optical port(E810XXVDA4G2P5 99A2H8)-quad-port-SFP28(optical module not included)-PCIE 4.0 X16-8086-1593|0005-4-full-height half-length-with driver package Current
0257Y122PCIe-network adapter-5885H V7-LPE35000-AP-Emulex -HBA Card LPE35000-AP-FC single-port-32Gb/s-PCIE 4.0 x8-Vendor ID 10DF-Device ID F400-1-with driver package Current
0257Y123PCIe-network adapter-5885H V7-LPE35002-AP-Emulex -HBA Card LPE35002-AP-FC dual-port-32Gb/s-PCIE 4.0 x8-Vendor ID 10DF-Device ID F400-2-with driver package Current
0257Y125PCIe-network adapter-5885H V7-QLE2772-CEM-BK-Qlogic-HBA Card QLE2772-CEM-BK-FC dual-port-32Gb/s-PCIE 4.0 x8-Vendor ID 1077-Device ID 2281-2-with driver package Current
0257Y150PCIe-network adapter-2288H V6-MCX623106AN-CDAT-network adapter-100Gb optical port(MCX623106AN-CDAT)-dual-port-QSFP56(optical module not included)-half-height half-length-PCIE 4.0 x16-15b3-101d-2-with driver package Current
0257Y152PCIe-network adapter-2288H V6-N25GPCIE03-network adapter-25Gb optical port(BCM957414A4142CC)-dual-port-SFP28(optical module not included)-PCIE 3.0 x8-14e4-16d7-2-with driver package Current
0257Y246PCIe-IB card-G8600 V7-MCX755106AS-HEAT-Infiniband MCX755106AS-HEAT-200Gb/s NDR200 IB,dual-port QSFP112-PCIE 5.0 x16-Vendor ID 15B3-Device ID 1021-2-Subvendor ID 15B3-Subdevice ID 0022(optical module not included) Current
0257Y302PCIe-network adapter-2288H V6-LPE36002-LPe36002-AP-FC HBA card-64Gb/s-dual-port-PCIE 4.0 x8-Vendor ID 10df-Device ID f400-2-Subvendor ID 10df-Subdevice ID f404-with driver package Current
0257Y390PCIe-network adapter-2288H V7-MCX75310AAS-NEAT-IB card-Infiniband MCX75310AAS-NEAT-NDR/NDR200/HDR100/EDR IB single-port OSFP-400Gb/s-PCIE 5.0 x16-Vendor ID 15B3-Device ID 1021-1-Subvendor ID 15B3-Subdevice ID 0023-with driver package Current
0257Y391PCIe-network adapter-2288H V7-MCX75310AAS-HEAT-IB card-Infiniband MCX75310AAS-HEAT-200Gb/s NDR200 IB,single-port OSFP-PCIE 5.0 x16-Vendor ID 15B3-Device ID 1021-1-Subvendor ID 15B3-Subdevice ID 0029-with driver package Current
0257Y476PCIe-network adapter-2288H V7-BCM957608-P2200GQF00-network adapter-200 Gigabit-64bit-QSFP56-2 ports-PCIE 5.0 x16-Vendor ID 14e4-Device ID 1760-2-Subvendor ID 14e4-Subdevice ID 9120-with driver package Current
0257Y506PCIe-GPU card-2258 V7-NVIDIA L2 GPU-GPU card-NVIDIA L2 GPU Accelerator-PN:900-2G193-0030-000/24GB GDDR6 Memory/300GB/s peak Memory Bandwidth/PCIE 4.0 x16-10DE-27B6-1,72W/HHHL,single-slot/Passive cooling-English documentation-No Cable Current
0257Y520PCIe-network adapter-2288H V7-BCM957508-P2100G-network adapter-100Gb optical port-dual-port-QSFP28-half-height half-length-PCIE 4.0 x16-Vendor ID 14e4-Device ID 1750-2-Subvendor ID 14e4-Subdevice ID 2100 Current
0257Y665PCIe-network adapter-2258 V7-E610XT2M5-PCIE 4.0 X4-Vendor ID 8086-Device ID 57b0-2-Subvendor ID 8086-Subdevice ID 0002 Current
0257Y701PCIe-GPU card-2288 V8-BC3L20GPU03-NVIDIA-Tesla L20 PCIe compute accelerator card-48GB-PCIe 4.0 x16 Current
0257Y761PCIe-GPU card-2288 V8-NL02-GPU card-NL02 GPU Accelerator-PN:900-2G133-00A0-000/48GB GDDR6 Memory/864GB/s Memory Bandwidth/PCIE 4.0 x16-10DE-26BA-1/350W-No NVLink-English documentation-Dual slot-Passive Current
0257Y787PCIe-network adapter-2288 V8-MCX631102AS-ADAT-network adapter-25 GE-64bit-SFP28-2-PCIE 4.0 x8-Vendor ID 15b3-Device ID 101f-2-Subvendor ID 15b3-Subdevice ID 0012-NA-Telefonica dedicated Current
0257Y821PCIe-network adapter-2258 V7-E835XXVDA2M-network adapter-2*25GE-64bit-SFP28-2 Ports-PCIE 4.0 X8-Vendor ID 8086-Device ID 124A-2-Subvendor ID 8086-Subdevice ID 0008-half-height half-length Current
3406Y008High Speed Transceiver,SFP28,850nm,25G,-8.4dBm,2.4dBm,-10.3dBm,LC,MM,0.1km,Original 34061254 split Current Field replaceable
3406Y006XFP|SFP+ Transceiver,SFP+,850nm,10Gb/s,-7.3dBm,-1dBm,-9.9dBm,LC,0.3km Current Field replaceable
3406Y011High Speed Transceiver,QSFP28,850nm,100G,-8.4dBm,2.4dBm,-10.3dBm,MPO,MM,0.1km,OM4 Original 34061089 split Current Field replaceable
3406Y007XFP|SFP+ Transceiver,SFP+,1310nm,10Gb/s,-8.2dBm,0.5dBm,-12.6dBm,LC,10km Current Field replaceable
0631Y027Network Card,100GE,64bit,QSFP56(without Optical Transceiver),2 Ports,PCIE 4.0 x16-15b3-101d-2,No Driver CD Current Field replaceable
0302Y043Manufactured Board,Public Module,CN21ITGBA1,XP210 I350 2*GE PCIE Card,PCIE 2.0 X4-Vendor ID 8086-Device ID 1521-2-Subvendor ID 1f24-Subdevice ID 2000,1*2 Current Field replaceable
0302Y044Manufactured Board,Public Module,CN21ITGC1,XP212 I350 4*GE PCIE Card,PCIE 2.0 X4-Vendor ID 8086-Device ID 1521-4-Subvendor ID 1f24-Subdevice ID 2001,1*2 Current Field replaceable
0302Y046Manufactured Board,Public Module,CN21ITGG1,XP330 Ethernet Adapter,10Gb Optical Interface(Intel X710),2-Port,SFP+(without Optical Transceiver),PCIE 3.0 X8-Vendor ID 8086-Device ID 1572-2-Subvendor ID 1f24-Subdevice ID 2003,1*2 Current Field replaceable
0302Y047Manufactured Board,Public Module,CN21ITGH1,XP332 Ethernet Adapter,10Gb Optical Interface(Intel XL710),4-Port,SFP+(without Optical Transceiver),PCIE 3.0 X8-Vendor ID 8086-Device ID 1572-4-Subvendor ID 1f24-Subdevice ID 2004,1*2 Current Field replaceable
0631Y040Network Card,25 GE,64bit,SFP28,2,PCIE 4.0 x8-15b3-101f-2,No Driver CD Current Field replaceable
0632Y074GPU Card,NVIDIA L20 GPU Accelerator,PN:900-2G133-00A0-000 / 48GB GDDR6 Memory / 864GB/s Memory Bandwidth /PCIE 4.0 x16-10DE-26BA-1 /350W,No NVLink,English doc,Dual slot,Passive Current Field replaceable
3406Y003Active Optical Cable Assembly,200GbE, QSFP56,IB HDR, 200Gb/s, LSZH, black pulltab,0.005km Current Field replaceable
3406Y033High Speed Transceiver,SFP28,850nm,25G,-8.4dBm,2.4dBm,-10.3dBm,LC,MM,0.1km,sont split Current Field replaceable
3406Y023High Speed Transceiver,QSFP56,850nm,200Gbps,-5.9dBm,4dBm,-4.4dBm,MPO12/UPC,MM,0.1km,8636 Current Field replaceable
3406Y012High Speed Transceiver,OSFP,850nm,400Gbps,-4.6dBm,4dBm,-4.4dBm,MPO-12/APC,MM,0.05km,OM4 Dedicated to IB NDR HCA Current Engineer replace
0603Y037Other Cards,HBA Card LPe36002-AP,FC dual Ports-64Gb/s,PCIE 4.0 x8-Vendor ID 10df-Device ID f400-2-Subvendor ID 10df-Subdevice ID f404,Chinese and English doc,half width half length Current Field replaceable
06310148Network Card,25 Gigabit,64bit,SFP28(without Optical Transceiver),2 Ports,PCIE 3.0 x8-14e4-16d7-2,No Driver CD Current Field replaceable
P/NDescription / SpecificationStatus
0257Y104PCIe-network adapter-2288H V6-X710DA2OCPV3-network adapter-2*10GE-64bit-SFP+(without optical module)-2 ports-PCIE 3.0 x8-8086-1572-2-OCP 3.0-with driver package Current
0257Y105PCIe-network adapter-2288H V6-X710T2LOCPV3-X710T2LOCPV3 Ethernet adapter-2*10GE(Intel X710)-dual-port-RJ45-PCIE 3.0 x8-8086-15FF-2-with driver package-OCP Current
0257Y107PCIe-network adapter-2288H V6-E810XXVDA2OCP3G-Ethernet adapter-25GE(Intel E810)-dual-port-SFP28-PCIE 4.0 x8-Vendor ID 8086-Device ID 159b-2-Subvendor ID 8086-Subdevice ID 0005-with driver package-OCP Current
0257Y131PCIe-network adapter-2288H V6-BCM957508-N2100G-network adapter-100 Gigabit-64bit-QSFP28-2 ports-PCIE 4.0 x16-14e4-1750-2,OCP-with driver package Current
0302Y054manufactured board-JDM-Public Module-BC53ETHF-XC310 GE350-T2 OCP3.0 Ethernet adapter-2*GE(I350)-dual-port-RJ45,PCIE 2.1 x4-Vendor ID 8086-Device ID 1521-2-Subvendor ID 1f24-Subdevice ID 200b-1*4 Current
0302Y237manufactured board-JDM-Public Module-BC53ETHH-XC331 OCP3.0 Ethernet adapter-10GE(BCM57416)-dual-port-RJ45-PCIE 3.0 X8-Vendor ID 14e4-Device ID 16d8-2-Subvendor ID 1f24-Subdevice ID 2010-1*3 Current
0302Y238manufactured board-JDM-Public Module-BC55ETHA-XC385 OCP3.0 Ethernet adapter-25GE(CX6-Lx)-dual-port-SFP28(optical module not included)-PCIE 4.0 X8-Vendor ID 15b3-Device ID 101f-2-Subvendor ID 1f24-Subdevice ID 2011-1*4 Current
0302Y239manufactured board-JDM-Public Module-BC55ETHB-XC381 OCP3.0 Ethernet adapter-25GE(E810)-dual-port-SFP28(optical module not included)-PCIE 4.0 X8-Vendor ID 8086-Device ID 159b-2-Subvendor ID 1f24-Subdevice ID 2012-1*4 Current
0302Y434manufactured board-JDM-Public Module-BC53ETHI-XC386 OCP3.0 Ethernet adapter-25GE(BCM57414)-dual-port-SFP28(optical module not included)-PCIE 3.0 X8-Vendor ID 14e4-Device ID 16d7-2-Subvendor ID 1f24-Subdevice ID 2013-1*4 Current
0302Y435manufactured board-JDM-Public Module-BC53ETHJ-XC333 OCP3.0 Ethernet adapter-10GE(BCM57412)-dual-port-SFP+(optical module not included)-PCIE 3.0 X8-Vendor ID 14e4-Device ID 16d6-2-Subvendor ID 1f24-Subdevice ID 2014-1*4 Current
0631Y043Network Card,100 Gigabit,64bit,QSFP28,2 ports,PCIE 4.0 x16-14e4-1750-2,No Driver CD,OCP Current Field replaceable
P/NDescription / SpecificationStatus
02313ADYfunction module-TS200-2280-BC11TPMC02-TPM2.0 card(SPI)-China dedicated Current
02313APLfunction module-TS200-2280-BC11TPMA02-TPM2.0 card(SPI)-international dedicated Current
03028HYWManufactured Board,TaiShan 200 (Model 2280),BC11TPMD,TPM2.0 Card(SPI), China Dedicated,5*4 Current Engineer replace
03024QEHManufactured Board,2288H V5,BC11TPMA,TPM2.0 Card(SPI), Overseas Dedicated,5*4 Current Engineer replace
P/NDescription / SpecificationStatus
0258Y596IO expansion module-drive-2288 V8-BC16M01MSMA-internal M.2 riser/adapter card,supports PCIE media(2U air-shroud mounting)-supports two M.2 media slot NONE
0258Y597IO expansion module-drive-2288 V8-BC16M12HBMA-internal M.2 riser/adapter card,supports SATA media(2U bracket mounting)-supports two M.2 media slot NONE
0258Y604IO expansion module-drive-2288 V8-BC16M04MSMA-internal M.2 riser/adapter card,supports PCIE media(2U IO1 Riser mounting)-supports two M.2 media slot NONE
0258Y605IO expansion module-drive-2288 V8-BC16M14HBMA-internal M.2 riser/adapter card,supports SATA media(2U IO1 Riser mounting)-supports two M.2 media slot NONE
0302012404manufactured board-2288H V7-BC15HBBA-8*2.5 inch SAS/SATA standard drive backplane-1*2 NONE
0302012412manufactured board-1288H V7-BC15HBBG-4*3.5 inch SAS/SATA standard drive backplane-1*4 NONE
0302012415manufactured board-2288H V7-BC15MSMA-internal M.2 riser/adapter card,supports PCH SATA/PCIe-2*1 NONE
0302012452manufactured board-2288H V7-BC15HBBE-IO1/IO2 2*2.5 inch SAS/SATA drive backplane-2*2 NONE
0302012461manufactured board-2288H V7-BC15HBBF-IO1/IO2 2*3.5 inch SAS/SATA drive backplane-2*4 NONE
0302012464manufactured board-2288H V7-BC15HBBI-IO3 4*SAS/SATA/NVMe drive backplane-1*4 NONE
0302Y083manufactured board-2288H V7-BC15HBED-25*2.5inch HDD Expander drive backplane-1*2 NONE
0302Y380manufactured board-2288H V7-BC15HBEE-12*3.5inch HDD Expander drive backplane(24port)-1*2 NONE
0302Y650manufactured board-2258 V7-BC15NHBR-12*3.5 inch SAS/SATA/NVMe drive backplane-1*2 NONE
0302Y676manufactured board-2258 V7-BC15NHBS-8*2.5 inch SAS/SATA/NVMe hard Raid drive backplane-1*2 NONE
0302Y683manufactured board-2258 V7-BC15HBBS-IO3 4*NVMe drive backplane-1*4 NONE
0302Y685manufactured board-2158H V8-BC26HBBA-8*3.5 inch SAS/SATA/NVME pass-through drive backplane-1*2 NONE
0302Y689manufactured board-2158H V8-BC26HBMA-PCIe to SATA M.2 backplane-1*1 NONE
0302Y859manufactured board-2288 V8-BC16HBBD-8*2.5 inch SAS/SATA 3Cage drive backplane-1*2 NONE
0302Y860manufactured board-2288 V8-BC16NHBC-8*2.5 inch SAS/SATA/NVMe 3Cage drive backplane-1*2 NONE
0302Y861manufactured board-2288 V8-BC16NHBD-12*3.5 inch(8*SAS/SATA+4*SAS/SATA/NVMe)drive backplane-1*2 NONE
0302Y962manufactured board-BC19NHBC--rear IO3 2*2.5"SAS/SATA/NVME horizontal drive backplane 1-2*2 NONE
0302YABXmanufactured board-2288 V8-BC16EHBA-14*E3.S 1T NVMe 3Cage drive backplane-1*2 NONE
0302YACCmanufactured board-BC19NHBDA--rear IO3 2*2.5"SAS/SATA/NVME horizontal drive backplane 2-2*2 NONE
P/NDescription / SpecificationStatus
02313XSFserver platinum 900W 2.0 versionAC power supply-ST(model PAC900S12-B2,interface IEC 320-C14) Current
0231Y019server platinum 2000W 2.0 versionAC power supply(model PAC2000S12-B1,interface IEC 320-C14) Current
0231Y021HVDC1500WB power supply module(model PHD1500S12-B2,interface Rongfeng RF-203 high-voltage input terminal) Current
0231Y025server titanium 2000W AC power supply module(model PAC2000S12-T1,interface IEC 320-C14) Current
0231Y033server platinum 1500W 2.0 versionAC power supply(model PAC1500S12-B1,interface IEC 320-C14) Current
0231Y265900W titanium AC power supply(model PAC900S12-T1,interface IEC 320-C14) Current
0231Y493server DC power supply-68mm-1200W-air-cooled(incl. DC power cord)(model PDC1200S12-CF1,interface Phoenix SPT 5/3-H-7,5-ZB model crimp terminal) Current
0231YEKUprimary power supply-XA3000-server titanium 3000W AC power supply(model XA3000,interface IEC 320-C20) Current
0231Y017server platinum 900W 2.0 versionAC power supply(model PAC900S12-B2,interface IEC 320-C14) EOM
0231Y020Function Module,PDC1200S12-CF,Server 1200W DC power supply 48V Current Field replaceable
P/NDescription / SpecificationStatus
0255Y695SSD module-Servers-M.2 SSD-SATA 6Gb/s-240GB-80.0mm * 22.0mm * 3.58 mm(hot-swappable)-ER3 series Current
0255Y696SSD module-Servers-M.2 SSD-SATA 6Gb/s-240GB-80.0mm * 22.0mm * 3.58 mm(non-hot-swappable)-ER3 series Current
0255Y697SSD module-Servers-M.2 SSD-SATA 6Gb/s-480GB-80.0mm * 22.0mm * 3.58 mm(hot-swappable)-ER3 series Current
0255Y698SSD module-Servers-M.2 SSD-SATA 6Gb/s-480GB-80.0mm * 22.0mm * 3.58 mm(non-hot-swappable)-ER3 series Current
0255YCTNSSD module-Servers-M.2 SSD-NVMe PCIe-960GB-110.0mm * 22.0mm * 3.8 mm(non-hot-swappable)-PM9A3 series Current
0255YCULSSD module-Servers-M.2 SSD-NVMe PCIe-960GB-80.0mm * 22.0mm * 3.58 mm(non-hot-swappable)-PJ1 series Current
0255YCUYSSD module-Servers-M.2 SSD-NVMe PCIe-480GB-80.0mm * 22.0mm * 3.58 mm(non-hot-swappable)-PM9A3 series Current
0255YFBASSD module-Servers-M.2 SSD-SATA 6Gb/s-480GB-80.0mm * 22.0mm * 3.58 mm(hot-swappable)-ER3 series Current
0255YFBPSSD module-Servers-M.2 SSD-SATA 6Gb/s-480GB-80.0mm * 22.0mm * 3.58 mm(non-hot-swappable)-ER3 series Current
0255YFEJSSD module-Servers-M.2 SSD-NVMe PCIe-960GB-110.0mm * 22.0mm * 3.8 mm(non-hot-swappable)-PM9A3 series Current
0255YGFSSSD module-Servers-M.2 SSD-NVMe PCIe-960GB-80.0mm * 22.0mm * 3.58 mm-PJ1 series Current
0255YGFTSSD module-Servers-M.2 SSD-NVMe PCIe-480GB-80.0mm * 22.0mm * 3.58 mm-PM9A3 series Current
0256Y116RAID card module-2288 V8-BC16M01HBMAA-BC16HBMAA-8 port SATA cable card-no RAID-6Gb/s-no Cache(2U air-shroud mounting) Current
0256Y119RAID card module-2288 V8-BC16M02HBMAA-BC16HBMAA-8 port SATA cable card-no RAID-6Gb/s-no Cache(2U bracket mounting) Current
0256Y137RAID card module-2288 V8-BC16M04HBMAA-BC16HBMAA-8 port SATA cable card-no RAID-6Gb/s-no Cache(2U IO1 Riser mounting) Current
0256Y188RAID card module-1288 V8-BC16M07HBMAA-BC16HBMAA-8 port SATA cable card-no RAID-6Gb/s-no Cache(4GPU tray mounting) Current
90010339Liquid Manufactory Auxiliaries,Thermal Grease,X-23-7868-2D,Thermal Conductivity 3.6W/mK / 6.0W/mK,2g,Gap filling thermal conductive for customer use,1ml Current Engineer replace
03025VYYManufactured Board,TaiShan 2280 V2,BC82LCIA,Left Customer Interface,4*2 Current Engineer replace
43020237SAS Expander,NA,VROC KEY,RAID 0/1/10/5,Premium,100mW,0.125MB/s Current Engineer replace
0231YDVTFunction Module,2158H V8,BC1M12ERISE,2158H V8 Unpacking Inspection Module Current Field replaceable
0302YABTManufactured Board,2288 V8,BC16MBSCA,1288 V8/2288 V8 Server Motherboard,1*1 Current Field replaceable
0302Y855Manufactured Board,2288 V8,BC16MBSC,1288 V8/2288 V8 Server motherboard,1*1 Current Field replaceable
0302YABYManufactured Board,2288 V8,BC16PDBA,4GPU Power Distribute Board,2*2 Current Field replaceable
0231YGABFunction Module,2288 V8,BC16M01INTRD,2288 V8 Intrude Detection Module Current Engineer replace
0258Y740IO Extended Module-Hard Disk,2288 V8,BC16M07HBBE,2*2.5" Rear Hard Disk Backplane Module+1*x16 Slot(PCIe 5.0)IO1 Riser card Module for EXP Current Engineer replace
0258Y584IO Extended Module-PCIE,2288 V8,BC16M01PRUEA,1*16X SLOT(PCIE5.0)-RISER3 PSU module Current Engineer replace
0258Y583IO Extended Module-PCIE,2288 V8,BC16M01PRUE,2*8X SLOT(PCIE5.0)-RISER3 PSU module Current Engineer replace
0258Y581IO Extended Module-PCIE,2288 V8,BC16M01PRUD,1*16X SLOT(PCIE5.0)-rear 4GPU/10 HDD IO1/2 RISER Module Current Engineer replace
0258Y719IO Extended Module-PCIE,2288 V8,BC16M02CNTD,Management Port-Front IO3 module Current Engineer replace
0258Y718IO Extended Module-PCIE,2288 V8,BC16M01CNTD,2*8X SLOT(PCIE5.0)&Management Port-Front IO3 module Current Engineer replace
0258Y717IO Extended Module-PCIE,2288 V8,BC16M02PRUG,1*8X SLOT(PCIE5.0)-Front IO2 module Current Engineer replace
0258Y716IO Extended Module-PCIE,2288 V8,BC16M01PRUG,2*8X SLOT(PCIE5.0)-Front IO3 module Current Engineer replace
0258Y714IO Extended Module-Hard Disk,2288 V8,BC16M01HBBG,inner 4*3.5 inch Hard Disk Backplane Module Current Field replaceable
0258Y578IO Extended Module-PCIE,2288 V8,BC16M01PRUI,2*16X SLOT(PCIE5.0)-IO1&2 module(FHFLSW PCIe card dedicated) Current Engineer replace
0258Y699IO Extended Module-PCIE,2288 V8,BC16M04PRUL,2*16X SLOT(PCIE5.0)-IO1&2 module,Spare Parts Current Engineer replace
0258Y611IO Extended Module-PCIE,2288 V8,BC16M03PRUL,2*16X SLOT(PCIE5.0)-IO1&2 GPU module Current Engineer replace
0258Y599IO Extended Module-Hard Disk,2288 V8,BC16M01HBBF,2*3.5" IO1 Rear Hard Disk Backplane Module Current Engineer replace
0258Y577IO Extended Module-PCIE,2288 V8,BC16M01PRUL,2*16X SLOT(PCIE5.0)-IO1&2 module Current Engineer replace
0258Y598IO Extended Module-Hard Disk,2288 V8,BC16M02HBBS,Rear 4*2.5" Hard Disk Backplane Module for NVMe,PCIE5.0(NUMA dedicated) Current Engineer replace
0258Y576IO Extended Module-PCIE,2288 V8,BC16M01PRUN,1*16X SLOT(PCIE5.0)+2*8X SLOT(PCIE4.0)-IO1&2 module Current Engineer replace
0258Y597IO Extended Module-Hard Disk,2288 V8,BC16M12HBMA,Built in M.2 riser card, Supporting SATA media(2U bracket install),Supports two M.2 media slots Current Engineer replace
0258Y575IO Extended Module-PCIE,2288 V8,BC16M01PRUKA,2*8X SLOT(PCIE5.0)-IO1&2 module Current Engineer replace
0258Y596IO Extended Module-Hard Disk,2288 V8,BC16M01MSMA,Built in M.2 riser card, Supporting PCIE media(2U air duct install),Supports two M.2 media slots Current Engineer replace
0258Y574IO Extended Module-PCIE,2288 V8,BC16M01PRUK,1*16X SLOT(PCIE5.0)+2*8X SLOT(PCIE5.0)-IO1&2 module Current Engineer replace
0258Y695IO Extended Module-PCIE,2288 V8,BC16M02PRUK,1*16X SLOT(PCIE5.0)+2*8X SLOT(PCIE5.0)-IO1&2 module,Spare Parts Current Engineer replace
0258Y750IO Extended Module-Hard Disk,2288 V8,BC16M03HBBF,2*3.5" IO1&2 Rear Hard Disk Backplane Module for EXP Current Field replaceable
0258Y595IO Extended Module-Hard Disk,2288 V8,BC16M02HBBE,2*2.5" Rear Hard Disk Backplane Module+1*x16 Slot(PCIe 5.0)IO2 Riser card Current Engineer replace
0258Y594IO Extended Module-Hard Disk,2288 V8,BC16M01HBBE,2*2.5" Rear Hard Disk Backplane Module+1*x16 Slot(PCIe 5.0)IO1 Riser card Current Engineer replace
0258Y792IO Extended Module-PCIE,2288 V8,BC16M01QHLHH,4*8X SLOT(PCIE5.0)-RISER3 PSU module Current Engineer replace
0258Y607IO Extended Module-PCIE,2288 V8,BC16M02PRUL,2*16X SLOT(PCIE5.0)-IO1&2 module(support cable card) Current Engineer replace
0258Y606IO Extended Module-PCIE,2288 V8,BC16M02PRUKA,2*8X SLOT(PCIE5.0)-IO1&2 module(support cable card) Current Engineer replace
0258Y605IO Extended Module-Hard Disk,2288 V8,BC16M14HBMA,Built in M.2 riser card, Supporting SATA media(2U IO1 Riser install),Supports two M.2 media slots Current Engineer replace
0258Y604IO Extended Module-Hard Disk,2288 V8,BC16M04MSMA,Built in M.2 riser card, Supporting PCIE media(2U IO1 Riser install),Supports two M.2 media slots Current Engineer replace
0258Y724IO Extended Module-PCIE,2288 V8,BC16M01PRUEC,2*16X SLOT(PCIE5.0)-RISER3 PSU module Current Engineer replace
0258Y603IO Extended Module-Hard Disk,2288 V8,BC16M04HBBE,2*2.5" Rear IO2 Hard Disk Backplane Module Current Engineer replace
0258Y723IO Extended Module-PCIE,2288 V8,BC16M02PRULA,3*16X SLOT(PCIE5.0)-IO2 module Current Engineer replace
0258Y602IO Extended Module-Hard Disk,2288 V8,BC16M03HBBE,2*2.5" Rear IO1 Hard Disk Backplane Module Current Engineer replace
0258Y722IO Extended Module-PCIE,2288 V8,BC16M01PRULA,3*16X SLOT(PCIE5.0)-IO1 module Current Engineer replace
0258Y787IO Extended Module-PCIE,2288 V8,BC16M01PRVA,2*16X SLOT(PCIE5.0)-IO1&2 DPU module Current Engineer replace
0258Y666IO Extended Module-PCIE,2288 V8,BC16M01PRHQ01,4GPU chassis second-layer Riser board-IO module 1 Current Field replaceable
0258Y743IO Extended Module-Hard Disk,2288 V8,BC16M02HBBI,IO3 4*2.5" Hard Disk Module for EXP Only Current Field replaceable
0258Y721IO Extended Module-PCIE,2288 V8,BC16M01PRUIA,1*16X SLOT(PCIE5.0)-IO1&2 module(support cable card) Current Engineer replace
0258Y600IO Extended Module-Hard Disk,2288 V8,BC16M02HBBF,2*3.5" IO2 Rear Hard Disk Backplane Module Current Engineer replace
0258Y588IO Extended Module-Hard Disk,2288 V8,BC16M01HBBS,Rear 4*2.5" Hard Disk Backplane Module for NVMe,PCIE5.0 Current Engineer replace
0258Y786IO Extended Module-Hard Disk,2288 V8,BC16M01NHBCD,IO3 4*2.5" SAS/SATA/NVMe Hard Disk Module Current Field replaceable
0258Y742IO Extended Module-Hard Disk,2288 V8,BC16M08HBBE,2*2.5" Rear Hard Disk Backplane Module+1*x16 Slot(PCIe 5.0)IO2 Riser card Module for EXP Current Engineer replace
0258Y720IO Extended Module-PCIE,2288 V8,BC16M01OCP3,OCP3 Mechanical part-Front IO3 module Current Engineer replace
0258Y587IO Extended Module-Hard Disk,2288 V8,BC16M01HBBI,Rear 4*2.5" Hard Disk Backplane Module for HDD Current Engineer replace
P/NDescription / SpecificationStatus
04052259Power cord,China AC Power 250V2.5A,2.0m,PISM,227IEC53-0.75^2(3C),C5SF,250V,2.5A,Black Current Engineer replace
04051080Power cord,South Africa AC Power 250V10A,3m,PMAM,H05VV-F-1.0mm^2(3C),C13SF,250V,10A,Black Current Engineer replace
04041119Power Cable,Switzerland AC Power Cable 250V10A,3.0m,PJSM ,H05VV-F-1.0mm^2(3C),C13SF,Black Current Engineer replace
04050517Power Cable,China AC Power Cable 250V10A,2.0m,PISM,227IEC53(RVV)1.0mm^2(3C),C13SF,Black Current Engineer replace
0415G005Power cord,China AC Power 250V10A,2.0m,C14SM,227IEC53-1.0^2(3C),C13SF,PDU Cable Current Engineer replace
0405G02CPower Cords Cable,China AC Power 250V10A,0.8m,C14SM,227IEC53 1.0^2(3C),C13SF,PDU Cable Current Engineer replace
0405G02DPower Cords Cable,Japan AC Power 250V12A,1.8m,C14SM,HVCTF 1.25^2(3C),C13SF,PDU Cable Current Engineer replace
04050955Power Cords Cable,China AC Power,250V10A,1.5m,PISM,227IEC53(RVV)1.0mm^2(3C),C13SF,250V,10A,Black Current Engineer replace
0405G02FPower Cords Cable,Australia AC Power 250V10A,1.8m,C14SM,H05VV-F-1.0^2(3C),C13SF,PDU Cable Current Engineer replace
04041117Power Cable,Britain AC Power Cable 250V10A,3.0m,PGAM ,H05VV-F-1.0mm^2(3C),C13AF-L,Black Current Engineer replace
0405G02HPower Cords Cable,Korea AC Power 250V10A,1.8m,C14SM,H05VV-F-1.0^2(3C),C13SF,PDU Cable Current Engineer replace
0405G02KPower Cords Cable,Denmark AC Power 250V10A,3m,PKSM,H05VV-F-3*1.0^2(3C),C13SF,Black Current Engineer replace
0405G028Power Cords Cable,Korea AC Power 250V10A,3m,PFSM,H05VV-F 3*1.0^2(3C),C13SF,Black Current Engineer replace
04050588Power cord,China AC Power Cable250V10A,1.5 m,C14SM,(227IEC53(RVV)1.0mm^2(3C)),C13SF,250V,10A,White,PDU Cable Current Engineer replace
0405G029Power Cords Cable,North America AC Power 250V10A,1.8m,C14SM,SJT 18AWG(3C),C13SF,PDU Cable Current Engineer replace
04050784Power Cords Cable,China AC Power Cable,250V16A,2m,C14SM,227IEC53-1.0^2(3C),C13SF,Yellow Current Engineer replace
04051035Power cord,India AC Power 250V6A,3m,PM-IIAM,IS 694-1.0^2(3C),C13 SF,250V,6A,Black Current Engineer replace
04050188Power Cords Cable,China AC Power 250V10A,1.5m,C14SM,227IEC53(RVV)1.0mm^2(3C),C13SF,PDU Cable Current Engineer replace
04020728Power Cable,America AC Power Cable,125V10A,3.0m,PBSM,18SJT(3C),C13SF,Black Current Engineer replace
04042698Power Cords Cable,China AC Power 250V10A,15.0m,PISM,227IEC53-1.0^2(3C),C13SF,Black Current Engineer replace
04042697Power Cords Cable,China AC Power 250V10A,10.0m,PISM,227IEC53-1.0^2(3C),C13SF,Black Current Engineer replace
04042699Power Cords Cable,China AC Power 250V10A,20.0m,PISM,227IEC53-1.0^2(3C),C13SF,Black Current Engineer replace
04041120Power Cable,Italy AC Power Cable 250V10A,3.0m,PLSM,H05VV-F-1.0mm^2(3C),C13SF,Black Current Engineer replace
04047785Power Cords Cable,Argentina AC Power 250V10A,3.0m,PISM,H05VV-F-1.0mm^2(3C),C13SF,Black Current Engineer replace
04052137Power cord,Taiwan AC 125V11A,3.0m,PBSM,HVCTF 3*1.25mm2,C13SF,125V,11A,Black,BSMI Current Engineer replace
04040888Power Cords Cable,Australia AC Power Cable,250V 10A,3.0m,PISM,H05VV-F-1.0mm^2(3C),C13SF,Black Current Engineer replace
04040889Power cord,BS546 250V10A,3.0m,PM-IAM,H05VV-F-1.5mm^2(3C),C13SF,250V,10A,Black Current Engineer replace
0405G019Power Cords Cable,Europe AC 250V10A,1.8m,C14SM,H05VV-F- 3*1.00^2,C13SF,PDU Cable Current Engineer replace
04050373Power cord,China AC Power Cable250V10A,1.0m,C14SM,(227IEC53(RVV)-1.0mm^2(3C)),C13SF,Black,PDU Cable Current Engineer replace
04041056Power cord,Europe AC Power Cable,250V10A,3.0m,PFSM,(H05VVF 1.0^2(3C)),C13SF,250V,10A,BLack Current Engineer replace
04050139Power Cords Cable,China AC Power Cable,250V10A,3m,PISM,227IEC53-1.0^2(3C),C13SF,Black Current Engineer replace
04150258Power Cable,Brazil AC Power Cable 250V10A,3.0m,PNSM ,H05VV-F-1.0mm^2(3C),C13SF,Black Current Engineer replace
04040887Power Cable,Japan AC Power Cable 125V12A,3.0m,PBSM,HVCTF-1.25mm^2(3C),C13SF,Black Current Engineer replace
14130923Optical Cable Parts,MPO/PC,MPO/PC,MULTI-MODE,15m,8 CORES,0m/0m,GJFH-8A1A.2(OM3),3.5MM,LSZH,60mm MPO,Bending insensitive Current Engineer replace
04050847Power cord,China AC Power Cable,250V10A,6.0m,C14SM,(227IEC53-1.0^2(3C)),C13SF,250V,10A,Black,PDU Cable Current Engineer replace
04051858Power cord,China AC Power Cable 250V10A,3.0m,PISM,227IEC53-1.0^2(3C),C13SF,250V,10A,Yellow Current Engineer replace
04041104Power Cords Cable,China AC Power 250V10A,3.0m,PISM,227IEC53-1.0^2(3C),C13SF,Black Current Engineer replace
04050846Power cord,China AC Power Cable,250V10A,3.0m,C14SM,(227IEC53-1.0^2(3C)),C13SF,250V,10A,Black,PDU Cable Current Engineer replace
04050206Power Cable,China AC Power Cable 250V10A,1.0m,PISM,227IEC53(RVV)1.0mm^2(3C),C13SF,Black Current Engineer replace
04040890Power Cable,Britain AC Power Cable 250V10A,3.0m,PGAM ,H05VV-F-1.0mm^2(3C),C13SF,Black Current Engineer replace
14270054BTB Connector module,74,UBC 8X curved,250mm,0.16mm,10mm,3200MB/s,1.57mm,Wire mounting,Y Current Engineer replace
0405Y011High Speed Cable,25G SFP28 Passive High Speed Cable,3m,SFP28,CC2P0.254B(S),SFP28 Current Engineer replace
0405Y017High Speed Cable,HS Cable Slimline-2*mini SAS HD,0.8m&0.7m,Slimline X8 STR,2*((31AWG*1Pair+31AWG*2Drain)*8+31AWG*1Pair*4),2*Internal mini SAS HD R/A,Slimline-2*mini SAS HD Current Engineer replace
04051074Power cord,India AC Power 250V 16A,3m,PM-IIIAM,IS 694-1.5mm^2(3C),C19SF,250V,16A,Black Current Engineer replace
0405Y010High Speed Cable,25G SFP28 Passive High Speed Cable,1m,SFP28,CC2P0.254B(S),SFP28 Current Engineer replace
04050422Power Cords Cable,China /Europe/America/Korea Multiple Certificate AC Power 250V16A,3.0m,C20SM,H05VV-F-1.5mm^2(3C) +14SJT3(3C),C19SF,PDU Cable Current Engineer replace
04051079Power cord,South Africa AC Power 250V16A,3m,PMAM,H05VV-F-1.5mm^2(3C),C19SF,250V,16A,Black Current Engineer replace
04152747Power Cable,1.8m,HVDC Straight Female,227IEC53(RVV)1.0mm^2(3C),C14SM Current Engineer replace
04051113IT Equipment Cable,Serial Port Cable,3m,D9 FM,CC2P0.32PWG1U,MP8-I Current Engineer replace
0405Y008High Speed Cable,10G Passive SFP+ Cable,1m,(SFP+20M),(CC2P0.254B),(SFP+20M),LSFRZH For Indoor,ETH 10GbE,LSZH Current Engineer replace
0405Y128Power cord,Japan AC Power 250V15A,3.0m,NEMA5-15PSM,HVCTF-2.0mm^2(3C)black,C19SF,125V,15A Current Engineer replace
0405Y007High Speed Cable,10G SFP+ High Speed Cable,3m,SFP+20M,CC2P0.254B(S),SFP+20M,LSFRZH For Indoor,ETH 10GbE,LSZH Current Engineer replace
04043396Power Cords Cable,China AC Power 250V16A,3.0m,PIAM,227IEC53-2.5^2(3C),C19SF,Black Current Engineer replace
0415Y642Power Cable,250V-16A 3m,2.5mm^2(3C),black,C21,2.5mm^2(3C),C20 Current Engineer replace
04045184Power Cords Cable,Australia AC Power 250V16A,3.0m,PISM,H05VVF-2.5^2(3C),C19SF,Black Current Engineer replace
04051418Power cord,China AC Power 250V16A,30.0m,PIAM,227IEC53-2.5^2(3C),C19SF,250V,16A,Black Current Engineer replace
04052139Power cord,Taiwan AC 125V15A,3.0m,PBSM,VCTFK3*2.0mm2(3C),C19SF,125V,15A,Black,BSMI Current Engineer replace
04050189Power Cords Cable,China AC Power 250V 16A,1.0m,C20SM,227IEC53x1.5^2(3C),C19SF,PDU Cable Current Engineer replace
04044598Power Cords Cable,Europe AC Power 250V16A,3.0m,PFAM,H05VVF-1.5^2(3C),C19SF,Black Current Engineer replace
04044597Power cord,BS546 250V16A,3.0m,PM-IAM,H05VV-F-1.5mm^2(3C),C19SF,250V,16A,Black Current Engineer replace
04050850Power Cords Cable,Britain AC Power Cable,250V13A,3.0m,PG AM,H05VV-F-1.5mm^2(3C),C19 SF,Black Current Engineer replace
04151188Power Cable,1.5m,HVDC Straight Female,227IEC53(RVV)1.0mm^2(3C) Current Engineer replace
04050856Power Cords Cable,Australia AC Power 250V16A,3.0m,C20SM,H05VV-F-1.5^2(3C),C19SF,PDU Power Cord Current Engineer replace
04150259Power Cords Cable,Brazil AC Power 250V16A,3.0m,PN-ISM ,H05VVF-1.5^2(3C),C19SF,Black Current Engineer replace
04050855Power Cords Cable,Japan AC Power 250V15A,3.0m,C20SM,VCTF-2.0^2(3C),C19SF,PDU Power Cord Current Engineer replace
04044603Power Cords Cable,North America AC Power 125V20A,3.0m,NEMA5-20PAM,12SJT(3C),C19SF,Black Current Engineer replace
0405Y033High Speed Cable,Internal HS Cable,1.0m&0.85m,Internal Mini SAS HD R/A,(1P*30AWG+ 2*Drain)*16+16C*30AWG,2*Internal Mini SAS HD STR,Mini SAS HD-2*Mini SAS HD Current Engineer replace
04080980Monitor&Alarm Cable,Signal cable,0.2m,H2X9(2.0),14*28UL1685B/14*28UL1685B(S),H2X9(2.0) Current Engineer replace
04051322Power cord,Switzerland AC Power Cable,3m,PJ-II SM,H05VV-F-1.5mm^2(3C),C19SF,250V,16A Current Engineer replace
0405Y023High Speed Cable,HS Cable Slimline-2*mini SAS HD,0.65m&0.2m&0.35m,Slimline X8 STR,2*((31AWG*1Pair+31AWG*2Drain)*8+31AWG*1Pair*4),Internal mini SAS HD R/A+Internal mini SAS HD STR,Slimline-3*Mini SAS HD Current Engineer replace
0405Y026High Speed Cable,HS Cable Slimline-Mini SAS HD,0.4m,Slimline X8 STR,2*((31AWG*1Pair+31AWG*2Drain)*8+31AWG*1Pair*4),Internal mini SAS HD STR,Slimline-Mini SAS HD Current Engineer replace
04150441Power Cable,3.5m,4mm^2,2*T4^2GY,H07Z-K-4^2BL+H07Z-K-4^2B,2*T4^2GY,LSZH Current Engineer replace
04152464Power Cable,0.5m,4mm^2,(OT6-4),(H07Z-K-4^2G&Y),(OT6-6),LSZH,YES Current Engineer replace
04052307High Speed Cable,200G to 2x100G HDR QSFP56 Passive High Speed Cable,1m,QSFP56,CC8P0.4B(S),QSFP56,IB-Mellanox,LSZH Current Engineer replace
0405Y121IT Equipment Cable,Signal Cable,0.65m,(H2X25(1.0)),(4*(1P*30AWG+1*Drain)+3* 30AWG Shield+4*(1P*30AWG)+22*UL1571 28AWG),(H2X25(1.0)) Current Engineer replace
0415Y029Power Cable,0.65m&0.63m,2*6.0mm^2,red/black,80A R/A easy connector,10UL1015RE+10UL1015BL,2*OT6-4 Current Engineer replace
04153757Power Cable,0.52m,black,80A R/A easy connector,5*18UL2651,80A R/A easy connector Current Engineer replace
1427Y148BTB Connector module,74,UBC 8X curved,900mm,0.16mm,10mm,22500MB/s,1.57mm,Wire mounting,Y Current Engineer replace
0405Y351High Speed Cable,Internal PCIe5.0 HS Cable,0.25m,MCIO X8 STR,(16*(1P*30AWG+2*Drain)+8*(1P*30AWG+1*Drain)+(4C*30AWG)),MCIO X8 STR Current Engineer replace
0405Y303High Speed Cable,HS Cable Slimline-2*MCIO X4,0.8m&0.7m,Slimline X8 STR,(2*(8*(1P*30AWG+2Drain)+4*(1P*30AWG+2Drain))),2*MCIO X4 STR,Slimline-2*MCIO X4 Current Engineer replace
0415Y210Power Cable,0.50m&0.62m,Black,80A R/A easy connector,20*18UL2651B,2*80A STR easy connector,Parallel Current Engineer replace
0405Y018High Speed Cable,HS Cable Slimline-2*mini SAS HD,0.65m&0.55m,Slimline X8 STR,2*((31AWG*1Pair+31AWG*2Drain)*8+31AWG*1Pair*4),2*Internal mini SAS HD R/A,Slimline-2*mini SAS HD Current Engineer replace
14270056BTB Connector module,74,UBC 8X curved,500mm,0.16mm,10mm,22500MB/s,1.57mm,Wire mounting,Y Current Engineer replace
0405Y384High Speed Cable,Internal PCIe5.0 HS Cable,550&600&550mm,GEN-Z 4C+ 168P STR,18*(1P*30AWG+2*Drain)+45C*30AWG,MCIO X8 STR+H2x20(1.25)+H2x2(4.2) Current Engineer replace
0415Y023Power Cable,0.60m,Black,H2X4(4.2),8*18UL1569B,H2X4(4.2),CPU8-CPU8 Current Engineer replace
0415Y030Power Cable,0.65m,Black,H2X4(4.2)-I,8*18UL1569B,H2X4(4.2)-I,PCIE88-PCIE8 Current Engineer replace
0405Y371High Speed Cable,HS Cable Slimline-MCIO X4+2*mini SAS HD,0.60m&0.2m&0.35m,Slimline X8 STR,(16*(1P*30AWG+2Drain)+16C*30AWG),MCIO X4 STR+2*mini SAS HD STR,Slimline-MCIO X4+2*mini SAS HD Current Engineer replace
0408Y010Monitor&Alarm Cable,Signal cable,0.60m,H2X6(2.0),8*28UL1685B/2*28UL1685B(S)/24UL1569B,H2X6(2.0),Fan board signal cable-1/3pin sheild Current Engineer replace
0408Y257Monitor&Alarm Cable,signal cable,0.48m,H2X20(1.25),12*28UL1685B/2*28UL1685B(S),H2X8(2.0) Current Engineer replace
0408Y015Monitor&Alarm Cable,signal cable,0.58&0.71&0.84M,H2X20(1.25),27*UL1685 28AWG/6*UL1685 28AWG,3*H2X6(2.0) Current Engineer replace
0405Y353High Speed Cable,Internal PCIe5.0 HS Cable,300&250mm,2*(MCIO X8 STR),(32*(1P*30AWG+2*Drain)+16*(1P*30AWG+1*Drain)+(8C*28AWG)),2*(MCIO X8 RA) Current Engineer replace
0405Y352High Speed Cable,Internal PCIe5.0 HS Cable,460&410mm,2*(MCIO X8 STR),32*(1P*30AWG+2*Drain)+16*(1P*30AWG+1*Drain)+(8C*30AWG),2*(MCIO X8 STR) Current Engineer replace
0408Y009Monitor&Alarm Cable,Signal cable,0.75m,H2X8(2.0),8*28UL1685B/2*28UL1685B(S)/24UL1569B,H2X8(2.0),Front HDDboard signal cable-4/6pin sheild Current Engineer replace
0408Y147Monitor&Alarm Cable,signal cable,0.50&0.84m,H2X20(1.25),21*UL1685 28AWG/4*UL1685 28AWG,2*H2X8(2.0) Current Engineer replace
0408Y146Monitor&Alarm Cable,signal cable,0.50&0.67&0.84m,H2X20(1.25),31*UL1685 28AWG/6*UL1685 28AWG,3*H2X8(2.0) Current Engineer replace
0408Y027Monitor&Alarm Cable,signal cable,0.33M,H2X15(1.25),27*UL1685 28AWG/6*UL1685 28AWG,(H2X15(1.25)) Current Engineer replace
0405Y441High Speed Cable,Internal PCIe5.0 HS Cable,600mm,Multi-Trak 16X,32*(1P*30AWG+2*Drain)+16*(1P*30AWG+1*Drain)+(8C*30AWG),2*(MCIO X8 STR) Current Engineer replace
0405Y440High Speed Cable,Internal PCIe5.0 HS Cable,420&600&550mm,GEN-Z 4C+ 168P STR,32*(1P*30AWG+2*Drain)+45C*30AWG,2*MCIO X8 STR+H2x20(1.25)+H2x2(4.2) Current Engineer replace
0408Y213Monitor&Alarm Cable,Signal cable,0.30m,H2X6(2.0),1*28UL1685B+1*24UL1569B+2*28UL1685B(S),H2X6(2.0) Current Engineer replace
0415Y648Power Cable,0.55&0.72m,Black,H2X6(3.0)+1X4(2.0),8*18UL1569B,2*(H2X4(3.0)+1X8(1.5)),Custom cables Current Engineer replace
0408Y217Monitor&Alarm Cable,Signal Cable,0.75m,H2X10(2.0),(8*28UL1685B)+2*28UL1685B(S),H2X10(1.0) Current Engineer replace
0408Y214Monitor&Alarm Cable,Signal cable,0.20m,H2X8(2.0),1*28UL1685B+1*24UL1569B+2*28UL1685B(S),H2X6(2.0) Current Engineer replace
0405Y039IT Equipment Cable,Signal Cable,0.25m,(H2X25(1.0)),(4*(1P*30AWG+1*Drain)+4* 30AWG Shield+2*(1P*30AWG)+26*UL1571 28AWG),(H2X25(1.0)) Current Engineer replace
0405Y393High Speed Cable,HS Cable Slimline-MCIO X4+mini SAS HD,0.65m&0.45m,Slimline X8 STR,(16*(1P*30AWG+2Drain)+16C*30AWG),MCIO X4 STR+mini SAS HD STR,Slimline-MCIO X4+mini SAS HD Current Engineer replace
0405Y032High Speed Cable,Internal HS Cable,0.40m&0.35m&0.25m,Slimline X8 STR,(31AWG*1Pair+32AWG*2Drain)*16+30AWG*1C*16,3*Internal Mini SAS HD STR,Slimline-3*Mini SAS HD Current Engineer replace
0405Y305High Speed Cable,HS Cable Slimline-2*MCIO X4,0.8m&0.7m,Slimline X8 STR,(2*(8*(1P*30AWG+2Drain)+4*(1P*30AWG+2Drain))),2*MCIO X4 R/A,Slimline-2*MCIO X4 Current Engineer replace
0405Y304High Speed Cable,HS Cable Slimline-MCIO X4,0.6m,Slimline X8 STR,(8*(1P*30AWG+2Drain)+4*(1P*30AWG+2Drain)),MCIO X4 R/A,Slimline-MCIO X4 Current Engineer replace
P/NDescription / SpecificationStatus
0231Y191Function Module,2288H V7,BC1M22FAN,8038+ Fan module Current Field replaceable
0231YBMCFunction Module,CS210 V1,CM1M02FAN,8056+ Fan module Current Field replaceable
2116Y198Heatsink-2116Y198_DRAEN.ASM-2U heat sink-118mm*78mm*64mm-Soldering-special heat sink Current Engineer replace
2116Y201Heatsink-2116Y201_DRAEN.ASM-1U body heatsink-118mm*78mm*25mm-Soldering-special heat sink Current Engineer replace
2116Y200Heatsink-2116Y200_DRAEN.ASM-2U heat sink-213mm*188.5mm*64mm-Soldering-special heat sink Current Engineer replace
2116Y199Heatsink-2116Y199_DRAEN.ASM-2U heat sink-213mm*188.5mm*25mm-Soldering-special heat sink Current Engineer replace
2116Y204Heatsink-2116Y204_DRAEN.ASM-1U inside the board remote hestsink-192mm*180mm*28.7mm-Soldering-special heat sink Current Engineer replace
0231YDSBFunction Module,2158H V8,BC1M22FAN01,6056Fan module(126W) Current Field replaceable
0231YGGQFunction Module,2288 V8,BC16FAN60M01,6056+ Fan module(170W) Current Field replaceable
0302Y693Manufactured Board,2158H V8,BC26FDTA,AMD Server 2U1P Fan Board 6*6056,1*2 Current Field replaceable

Operating System Compatibility

Operating SystemVersion / KernelRelease
RHEL 9.45.14.0-427.13.1.el9_4.x86_64Red Hat Enterprise Linux 9 Update 4 Server for Intel EM64T
RHEL 9.65.14.0-570.12.1.el9_6.x86_64Red Hat Enterprise Linux 9 Update 6 Server for Intel EM64T
RHEL 9.75.14.0-611.5.1.el9_7.x86_64Red Hat Enterprise Linux 9 Update 7 Server for Intel EM64T
RHEL 9.85.14.0-687.5.3.el9_8.x86_64Red Hat Enterprise Linux 9 Update 8 Server for Intel EM64T
Rocky Linux 9.65.14.0-570.17.1.el9_6.x86_64Rocky Linux 9 Update 6 Server for Intel EM64T
Rocky Linux 9.75.14.0-611.5.1.el9_7.x86_64Rocky Linux 9 Update 7 Server for Intel EM64T
Rocky Linux 9.85.14.0-687.10.1.el9_8.0.1.x86_64Rocky Linux 9 Update 8 Server for Intel EM64T
SLES 15 SP66.4.0-150600.21-defaultSUSE Linux Enterprise Server 15 Service Pack 6 for AMD64 & Intel64
Ubuntu 24.04 LTS6.8.0-31-genericUbuntu 24.04 LTS Server Edition for Intel EM64T
VMware ESXi 9.0build-24755229VMware ESXi 9.0 for Intel EM64T
VMware ESXi 9.1build-25370933VMware ESXi 9.1 for Intel EM64T
Windows Server 2022Build 20348Microsoft Windows Server 2022 x64
Windows Server 2025Build 26100Microsoft Windows Server 2025 x64
openEuler 24.03 LTS SP16.6.0-72.0.0.76.oe2403sp1.x86_64openEuler 24.03 LTS SP1 (powered by openEuler)

Configuring, expanding or replacing this server? Send us your part list or BOM for a fast quotation.

Request a Quote

Selecting components for the 2288 V8

A few points from the matrix matter when configuring or expanding a unit:

  • Two CPU roadmaps, one socket. The listed Granite Rapids parts run from the 8-core Xeon 6505P / 6714P up to the 86-core Xeon 6787P, while the Sierra Forest efficiency line spans 64 to 144 cores (Xeon 6710E through 6766E). Pick P-series for per-thread performance and licensed database workloads, E-series when core density and performance per watt matter more.
  • Memory scales with the workload. Validated DDR5 RDIMMs include 32GB, 64GB, 96GB and 128GB capacities at 6400 MT/s. The 96GB and 128GB modules are typically marked for 3-way OEM qualification — tell us your target capacity and we will confirm the validated population rules.
  • RAID levels follow the controller. Entry SAS3808-based controllers support RAID 0/1/10 with no cache; the SAS3916-based 16i cards add RAID 5/6/50/60 with 4GB cache and a supercapacitor. A SAS3808 M.2 boot card (RAID 0/1/JBOD) frees the front bays for data drives, and Intel VROC standard/advanced keys are listed for NVMe RAID.
  • Networking from 1GbE to 100GbE. OCP 3.0 adapters cover dual-GbE (I350), 10GbE (BCM57416), 25GbE (E810, BCM57414, ConnectX-6 Lx) and dual-port 100GbE QSFP28. PCIe cards add X710/XL710 10GbE and external SAS options.
  • Power for every rack standard. The list includes 900W to 3000W AC PSUs in platinum and titanium ratings (IEC C14/C20), a 1500W HVDC module, and a 1200W −48V DC supply — useful for telecom and co-location DC racks.
  • Security is region-specific. Two TPM 2.0 modules are listed: one China-dedicated and one international-dedicated. Confirm which variant your region and compliance regime require.

Reference workload profiles

These profiles illustrate how validated components combine; we configure and quote each one to order.

  • Virtualization / private cloud: dual Xeon 6530P or 6527P, high-density DDR5 RDIMMs, hardware RAID with cache + supercap, dual 10/25GbE, redundant platinum or titanium PSUs.
  • Database (SQL / in-memory): high-frequency Granite Rapids CPUs, large RDIMM footprint, PCIe 5.0 NVMe for redo/log and hot data, SAS capacity drives for bulk.
  • Scale-out / cloud-native: Sierra Forest E-series CPUs for maximum core density, dual 25/100GbE fabric, M.2 boot, 1U-style lean power configuration.
  • All-flash storage node: 16i RAID (5/6 capable) or HBA passthrough, a full set of PCIe 5.0 NVMe SSDs, a high-wattage titanium PSU for the power draw.
  • Big-data / content repository: mid-bin P-series CPUs, 16–20TB 3.5" SATA or 2.4TB 10K SAS drives, cost-effective RAID and 10GbE links.

How the V8 compares with earlier 2288 generations

The 2288 line has been xFusion’s mainstream 2U platform for several generations. Understanding the differences helps when deciding between new V8 units and supported V5–V7 hardware for budget projects:

  • 2288 V8 (current): Intel Xeon 6 (Granite Rapids / Sierra Forest), DDR5, PCIe 5.0 NVMe, the newest long-lifecycle platform — our default for new deployments.
  • 2288H V7: 4th/5th Gen Intel Xeon Scalable, DDR5, PCIe 4.0/5.0 storage; a very large validated catalogue (850+ items) and strong value.
  • 2288H V6: 3rd Gen Intel Xeon Scalable, DDR4, PCIe 4.0; offered in 16-DIMM and 32-DIMM variants with the widest part catalogue of any 2288.
  • 2288H V5: 1st/2nd Gen Intel Xeon Scalable, DDR4; mature, widely deployed, well supported with spares.

We supply new V8 systems with the manufacturer warranty and can also source validated V5–V7 parts and complete units for cost-sensitive or standardised environments. Ask us which generation fits your budget, software licensing and support window.

FusionServer Pro 2288 V8 — compatibility FAQ

Which processors does the 2288 V8 support?

The matrix lists two families on the FCLGA4710 socket: Granite Rapids P-series from the 8-core Xeon 6505P and 6714P up to the 86-core Xeon 6787P, and Sierra Forest E-series efficiency CPUs from 64-core 6710E to the 144-core Xeon 6766E. Some high-end parts are still in DEVELOP status; confirm availability and the thermal/power envelope for your chassis before ordering.

What is the difference between Granite Rapids and Sierra Forest on this server?

Granite Rapids uses performance cores and suits databases, HPC and per-core-licensed software. Sierra Forest uses dense efficiency cores and suits web front-ends, containers, CDN and scale-out services where throughput per watt matters. Both are validated in the same 2288 V8 chassis.

What memory can I install?

Validated modules are ECC DDR5 RDIMMs in 32GB, 64GB, 96GB and 128GB capacities at 6400 MT/s (1.1V, 288-pin). Give us your capacity target and we will confirm the supported DIMM population and any channel interleaving rules.

Which RAID controller should I choose?

For boot and simple mirroring, the SAS3808-based controllers support RAID 0/1/10 with no cache. For data arrays needing parity, choose a SAS3916-based 16i card with 4GB cache and a supercapacitor for RAID 5/6/50/60. If you only need passthrough to software RAID, an SAS3816-IT HBA is listed with no RAID enabled.

Can I boot from M.2 and free the front bays?

Yes. A SAS3808-based M.2 boot card supporting RAID 0, RAID 1 and JBOD is validated, available in both full-height and half-height bracket variants.

Does it support NVMe RAID?

Intel VROC keys are listed in standard edition (RAID 0/1/10) and advanced edition (adds RAID 5), enabling CPU-attached NVMe RAID without a traditional hardware controller.

What NVMe and SAS drives are validated?

NVMe options include PCIe 5.0 x4 SSDs such as the Samsung PM9D3a and Solidigm SP530 series up to 7.68TB. SAS drives include 2.5" 10K models up to 2.4TB and 3.5" bulk SATA drives up to 20TB. Check the Hard Drives and NVMe SSDs tabs for the full list and current status.

What network speeds are supported?

OCP 3.0 adapters range from dual 1GbE (I350) and 10GbE to 25GbE (E810, BCM57414, ConnectX-6 Lx) and dual-port 100GbE QSFP28 (BCM957508). PCIe options add X710 dual-port and XL710 quad-port 10GbE. Optical modules are included with some SKUs and excluded from others — check the part description.

What power supplies are available?

The list runs from 900W platinum to 3000W titanium AC units (IEC C14 on most, C20 on the 3000W), plus a 1500W HVDC module and a 1200W −48V DC supply with Phoenix terminal. Redundant pairs can be configured for high availability.

Is a TPM module included?

Two TPM 2.0 modules are validated — one China-dedicated and one international-dedicated. They are typically selected by region and compliance requirements rather than fitted universally, so tell us which market the server is for.

What do Current, DEVELOP and EOM statuses mean?

Current (GA) parts are in production and orderable. DEVELOP parts are on the published roadmap or under qualification and may not yet ship in all regions. EOM (end of marketing) parts are no longer sold new but remain supported and are often available as spares — useful for repairing existing fleets.

Which operating systems are certified?

The OS matrix lists 14 builds including RHEL 9.4–9.8, Rocky Linux 9.6–9.8, SLES 15 SP6, Ubuntu 24.04 LTS, VMware ESXi 9.0/9.1, Windows Server 2022 and 2025, and openEuler 24.03 LTS SP1, each with its exact kernel or build string. Additional builds can often be confirmed on request.

Can you supply the server or just the spare parts?

Both. We configure complete 2288 V8 systems and supply every validated component listed here — CPUs, memory, drives, RAID and network cards, PSUs and modules — with new-product warranty. Send us a part list or BOM for a fast quotation.

Request a Quote  Look up a part number  All xFusion models

Leave a message