The FusionServer Pro 2288H V7 is 2U dual-socket rack server. It is the mainstream general-purpose 2U platform of this xFusion generation, designed for virtualization, databases and general compute. The platform runs on 4th/5th Generation Intel Xeon Scalable with DDR5 memory and PCIe 4.0/5.0 expansion.
Below is the verified compatibility matrix for this model: 858 validated line items across 11 component categories and 91 certified operating-system builds, taken from xFusion’s official compatibility data and presented in English. Every part number listed is published by xFusion for this chassis; nothing is guessed or cross-filled from other models.
Compatibility matrix
Browse validated parts by category using the tabs below. Each tab shows its item count; search inside a tab by part number or keyword, and expand the full list. Parts marked Current are actively orderable; life-cycle parts are still supported and often available as spares. The OS table lists the exact certified kernel or build.
| P/N | Description / Specification | Status |
|---|---|---|
| 4102Y016 | X86 series-FCLGA4677-2000MHz-1.6V/1.83V-64bit-350000mW-Sapphire Rapids XCC CPU-Intel Xeon Platinum 8480+-56Core | Current |
| 4102Y018-001 | X86 series-FCLGA4677-2100MHz-1.6V/1.83V-64bit-350000mW-Montage Jintide CPU C8468-48Core | Current |
| 4102Y020 | X86 series-FCLGA4677-2000MHz-1.6V/1.83V-64bit-300000mW-Sapphire Rapids XCC CPU-Intel Xeon Platinum 8452Y-36Core | Current |
| 4102Y020-001 | X86 series-FCLGA4677-2000MHz-1.6V/1.83V-64bit-300000mW-Montage Jintide CPU C8452Y-36Core | Current |
| 4102Y021 | X86 series-FCLGA4677-2100MHz-1.6V/1.83V-64bit-270000mW-Sapphire Rapids XCC CPU-Intel Xeon Gold 6430-32Core | Current |
| 4102Y021-001 | X86 series-FCLGA4677-2100MHz-1.6V/1.83V-64bit-270000mW-Montage Jintide CPU C6430-32Core | Current |
| 4102Y023-001 | X86 series-FCLGA4677-2700MHz-1.6V/1.83V-64bit-350000mW-Montage Jintide CPU C8458P-44Core | Current |
| 4102Y025 | X86 series-FCLGA4677-1900MHz-1.6V/1.83V-64bit-350000mW-Sapphire Rapids XCC CPU-Intel Xeon Platinum 8490H-60Core | Current |
| 4102Y026 | X86 series-FCLGA4677-2100MHz-1.6V/1.83V-64bit-330000mW-Sapphire Rapids XCC CPU-Intel Xeon Platinum 8468H-48Core | Current |
| 4102Y027 | X86 series-FCLGA4677-2200MHz-1.6V/1.83V-64bit-330000mW-Sapphire Rapids XCC CPU-Intel Xeon Platinum 8460H-40Core | Current |
| 4102Y028 | X86 series-FCLGA4677-2100MHz-1.6V/1.83V-64bit-270000mW-Sapphire Rapids XCC CPU-Intel Xeon Platinum 8454H-32Core | Current |
| 4102Y029 | X86 series-FCLGA4677-2000MHz-1.6V/1.83V-64bit-250000mW-Sapphire Rapids XCC CPU-Intel Xeon Platinum 8450H-28Core | Current |
| 4102Y030 | X86 series-FCLGA4677-2900MHz-1.6V/1.83V-64bit-270000mW-Sapphire Rapids XCC CPU-Intel Xeon Platinum 8444H-16Core | Current |
| 4102Y031 | X86 series-FCLGA4677-1700MHz-1.6V/1.83V-64bit-300000mW-Sapphire Rapids XCC CPU-Intel Xeon Platinum 8470N-52Core | Current |
| 4102Y032 | X86 series-FCLGA4677-1800MHz-1.6V/1.83V-64bit-300000mW-Sapphire Rapids XCC CPU-Intel Xeon Platinum 8471N-52Core | Current |
| 4102Y040-001 | X86 series-FCLGA4677-2100MHz-1.6V/1.83V-64bit-225000mW-Montage Jintide CPU C6448Y-32Core | Current |
| 4102Y043-001 | X86 series-FCLGA4677-2500MHz-1.6V/1.83V-64bit-185000mW-Montage Jintide CPU C6426Y-16Core | Current |
| 4102Y047-001 | X86 series-FCLGA4677-2000MHz-1.6V/1.83V-64bit-205000mW-Montage Jintide CPU C5420+-28Core | Current |
| 4102Y048 | X86 series-FCLGA4677-2000MHz-1.6V/1.83V-64bit-185000mW-Sapphire Rapids MCC CPU-Intel Xeon Gold 5418Y-24Core | Current |
| 4102Y048-001 | X86 series-FCLGA4677-2000MHz-1.6V/1.83V-64bit-185000mW-Montage Jintide CPU C5418Y-24Core | Current |
| 4102Y049-001 | X86 series-FCLGA4677-2000MHz-1.6V/1.83V-64bit-165000mW-Montage Jintide CPU C4416+-20Core | Current |
| 4102Y052 | X86 series-FCLGA4677-2400MHz-1.6V/1.83V-64bit-250000mW-Sapphire Rapids MCC CPU-Intel Xeon Gold 6448H-32Core | Current |
| 4102Y054 | X86 series-FCLGA4677-2200MHz-1.6V/1.83V-64bit-165000mW-Sapphire Rapids MCC CPU-Intel Xeon Gold 6416H-18Core | Current |
| 4102Y055 | X86 series-FCLGA4677-3700MHz-1.6V/1.83V-64bit-195000mW-Sapphire Rapids MCC CPU-Intel Xeon Gold 6434H-8Core | Current |
| 4102Y056 | X86 series-FCLGA4677-2000MHz-1.6V/1.83V-64bit-205000mW-Sapphire Rapids MCC CPU-Intel Xeon Gold 6438N-32Core | Current |
| 4102Y057 | X86 series-FCLGA4677-1800MHz-1.6V/1.83V-64bit-185000mW-Sapphire Rapids MCC CPU-Intel Xeon Gold 6428N-32Core | Current |
| 4102Y058 | X86 series-FCLGA4677-1800MHz-1.6V/1.83V-64bit-185000mW-Sapphire Rapids MCC CPU-Intel Xeon Gold 6421N-32Core | Current |
| 4102Y060 | X86 series-FCLGA4677-1900MHz-1.6V/1.83V-64bit-165000mW-Sapphire Rapids MCC CPU-Intel Xeon Gold 5411N-24Core | Current |
| 4102Y064 | X86 series-FCLGA4677-2000MHz-1.6V/1.83V-64bit-150000mW-Sapphire Rapids MCC CPU-Intel Xeon Gold 5416S-16Core | Current |
| 4102Y073 | X86 series-FCLGA4677-2300MHz-1.6V/1.83V-64bit-300000mW-Sapphire Rapids XCC CPU-Intel Xeon Platinum 8430C-36Core-Customized | Current |
| 4102Y074 | X86 series-FCLGA4677-2800MHz-1.6V/1.83V-64bit-350000mW-Sapphire Rapids XCC CPU-Intel Xeon Platinum 8432C-40Core | Current |
| 4102Y075 | X86 series-FCLGA4677-3300MHz-1.6V/1.83V-64bit-350000mW-Sapphire Rapids MCC CPU-Intel Xeon Gold 6460C-32Core | Current |
| 4102Y103 | X86 series-FCLGA4677-2600MHz-1.6V/1.83V-64bit-350000mW-Sapphire Rapids XCC CPU-Intel Xeon Platinum 8457C-48Core | Current |
| 4102Y103-B01 | X86 series-FCLGA4677-2600MHz-1.6V/1.83V-64bit-350000mW-Sapphire Rapids XCC CPU-Intel Xeon Platinum 8457C-48Core | Current |
| 4102Y106 | X86 series-FCLGA4677-2700MHz-1.6V/1.83V-64bit-385000mW-Emerald Rapids XCC CPU-Intel Xeon Platinum 8538C-56Core | Current |
| 4102Y109 | X86 series-FCLGA4677-2600MHz-1.6V/1.83V-64bit-385000mW-Emerald Rapids XCC CPU-Intel Xeon Platinum 8566C-52Core | Current |
| 4102Y110 | X86 series-FCLGA4677-2700MHz-1.6V/1.83V-64bit-350000mW-Emerald Rapids XCC CPU-Intel Xeon Platinum 8558P-48Core | Current |
| 4102Y112 | X86 series-FCLGA4677-2000MHz-1.6V/1.83V-64bit-330000mW-Emerald Rapids XCC CPU-Intel Xeon Platinum 8592V-64Core | Current |
| 4102Y113 | X86 series-FCLGA4677-1900MHz-1.6V/1.83V-64bit-350000mW-Emerald Rapids XCC CPU-Intel Xeon Platinum 8592+-64Core | Current |
| 4102Y114 | X86 series-FCLGA4677-2000MHz-1.6V/1.83V-64bit-350000mW-Emerald Rapids XCC CPU-Intel Xeon Platinum 8580-60Core | Current |
| 4102Y116 | X86 series-FCLGA4677-2300MHz-1.6V/1.83V-64bit-350000mW-Emerald Rapids XCC CPU-Intel Xeon Platinum 8568Y+-48Core | Current |
| 4102Y117 | X86 series-FCLGA4677-2800MHz-1.6V/1.83V-64bit-300000mW-Emerald Rapids MCC CPU-Intel Xeon Platinum 8562Y+-32Core | Current |
| 4102Y118 | X86 series-FCLGA4677-2500MHz-1.6V/1.83V-64bit-250000mW-Emerald Rapids MCC CPU-Intel Xeon Gold 6548Y+-32Core | Current |
| 4102Y119 | X86 series-FCLGA4677-2900MHz-1.6V/1.83V-64bit-250000mW-Emerald Rapids MCC CPU-Intel Xeon Gold 6542Y-24Core | Current |
| 4102Y120 | X86 series-FCLGA4677-3600MHz-1.6V/1.83V-64bit-270000mW-Emerald Rapids MCC CPU-Intel Xeon Gold 6544Y-16Core | Current |
| 4102Y121 | X86 series-FCLGA4677-2800MHz-1.6V/1.83V-64bit-195000mW-Emerald Rapids MCC CPU-Intel Xeon Gold 6526Y-16Core | Current |
| 4102Y122 | X86 series-FCLGA4677-3900MHz-1.6V/1.83V-64bit-195000mW-Emerald Rapids MCC CPU-Intel Xeon Gold 6534-8Core | Current |
| 4102Y123 | X86 series-FCLGA4677-3200MHz-1.6V/1.83V-64bit-165000mW-Emerald Rapids MCC CPU-Intel Xeon Gold 5515+-8Core | Current |
| 4102Y124 | X86 series-FCLGA4677-2100MHz-1.6V/1.83V-64bit-330000mW-Emerald Rapids XCC CPU-Intel Xeon Platinum 8558-48Core | Current |
| 4102Y125 | X86 series-FCLGA4677-2200MHz-1.6V/1.83V-64bit-225000mW-Emerald Rapids MCC CPU-Intel Xeon Gold 6538Y+-32Core | Current |
| 4102Y126 | X86 series-FCLGA4677-2100MHz-1.6V/1.83V-64bit-270000mW-Emerald Rapids XCC CPU-Intel Xeon Gold 6530-32Core | Current |
| 4102Y127 | X86 series-FCLGA4677-2200MHz-1.6V/1.83V-64bit-205000mW-Emerald Rapids MCC CPU-Intel Xeon Gold 5520+-28Core | Current |
| 4102Y128 | X86 series-FCLGA4677-2200MHz-1.6V/1.83V-64bit-185000mW-Emerald Rapids MCC CPU-Intel Xeon Silver 4516Y+-24Core | Current |
| 4102Y129 | X86 series-FCLGA4677-2000MHz-1.6V/1.83V-64bit-150000mW-Emerald Rapids MCC CPU-Intel Xeon Silver 4514Y-16Core | Current |
| 4102Y131 | X86 series-FCLGA4677-3200MHz-1.6V/1.83V-64bit-350000mW-Emerald Rapids MCC CPU-Intel Xeon Gold 6558Q-32Core | Current |
| 4102Y135 | X86 series-FCLGA4677-2800MHz-1.6V/1.83V-64bit-250000mW-Emerald Rapids MCC CPU-Intel Xeon Gold 6548N-32Core | Current |
| 4102Y135-A01 | X86 series-FCLGA4677-2800MHz-1.6V/1.83V-64bit-250000mW-Emerald Rapids MCC CPU-Intel Xeon Gold 6548N-32Core-Sangfor | Current |
| 4102Y136 | X86 series-FCLGA4677-2100MHz-1.6V/1.83V-64bit-205000mW-Emerald Rapids MCC CPU-Intel Xeon Gold 6538N-32Core | Current |
| 4102Y137 | X86 series-FCLGA4677-2200MHz-1.6V/1.83V-64bit-270000mW-Emerald Rapids XCC CPU-Intel Xeon Gold 6554S-36Core | Current |
| 4102Y139 | X86 series-FCLGA4677-2400MHz-1.6V/1.83V-64bit-150000mW-Sapphire Rapids EE LCC 4510-12Core | Current |
| 4102Y140 | X86 series-FCLGA4677-2000MHz-1.6V/1.83V-64bit-115000mW-Sapphire Rapids EE LCC 4510T-12Core | Current |
| 4102Y222 | X86 series-FCLGA4677-2600MHz-1.6V/1.83V-64bit-125000mW-Sapphire Rapids EE LCC 4509Y-8Core | Current |
| 4102Y230 | X86 series-FCLGA4677-2600MHz-1.6V/1.83V-64bit-350000mW-Sapphire Rapids XCC CPU-Intel Xeon Platinum 8438C-48Core | Current |
| 4102Y017 | X86 series-FCLGA4677-2000MHz-1.6V/1.83V-64bit-350000mW-Sapphire Rapids XCC CPU-Intel Xeon Platinum 8470-52Core | EOM |
| 4102Y018 | X86 series-FCLGA4677-2100MHz-1.6V/1.83V-64bit-350000mW-Sapphire Rapids XCC CPU-Intel Xeon Platinum 8468-48Core | EOM |
| 4102Y019 | X86 series-FCLGA4677-2000MHz-1.6V/1.83V-64bit-300000mW-Sapphire Rapids XCC CPU-Intel Xeon Platinum 8460Y+-40Core | EOM |
| 4102Y022 | X86 series-FCLGA4677-2400MHz-1.6V/1.83V-64bit-330000mW-Sapphire Rapids XCC CPU-Intel Xeon Platinum 8468V-48Core | EOM |
| 4102Y023 | X86 series-FCLGA4677-2700MHz-1.6V/1.83V-64bit-350000mW-Sapphire Rapids XCC CPU-Intel Xeon Platinum 8458P-44Core | EOM |
| 4102Y024 | X86 series-FCLGA4677-2200MHz-1.6V/1.83V-64bit-300000mW-Sapphire Rapids XCC CPU-Intel Xeon Platinum 8461V-48Core | EOM |
| 4102Y034 | X86 series-FCLGA4677-2000MHz-1.6V/1.83V-64bit-250000mW-Sapphire Rapids XCC CPU-Intel Xeon Gold 6414U-32Core | EOM |
| 4102Y035 | X86 series-FCLGA4677-2200MHz-1.6V/1.83V-64bit-270000mW-Sapphire Rapids XCC CPU-Intel Xeon Gold 6454S-32Core | EOM |
| 4102Y039 | X86 series-FCLGA4677-2800MHz-1.6V/1.83V-64bit-300000mW-Sapphire Rapids MCC CPU-Intel Xeon Platinum 8462Y+-32Core | EOM |
| 4102Y040 | X86 series-FCLGA4677-2100MHz-1.6V/1.83V-64bit-225000mW-Sapphire Rapids MCC CPU-Intel Xeon Gold 6448Y-32Core | EOM |
| 4102Y041 | X86 series-FCLGA4677-2600MHz-1.6V/1.83V-64bit-225000mW-Sapphire Rapids MCC CPU-Intel Xeon Gold 6442Y-24Core | EOM |
| 4102Y042 | X86 series-FCLGA4677-3600MHz-1.6V/1.83V-64bit-270000mW-Sapphire Rapids MCC CPU-Intel Xeon Gold 6444Y-16Core | EOM |
| 4102Y043 | X86 series-FCLGA4677-2500MHz-1.6V/1.83V-64bit-185000mW-Sapphire Rapids MCC CPU-Intel Xeon Gold 6426Y-16Core | EOM |
| 4102Y044 | X86 series-FCLGA4677-3700MHz-1.6V/1.83V-64bit-195000mW-Sapphire Rapids MCC CPU-Intel Xeon Gold 6434-8Core | EOM |
| 4102Y045 | X86 series-FCLGA4677-2900MHz-1.6V/1.83V-64bit-150000mW-Sapphire Rapids MCC CPU-Intel Xeon Gold 5415+-8Core | EOM |
| 4102Y046 | X86 series-FCLGA4677-2000MHz-1.6V/1.83V-64bit-205000mW-Sapphire Rapids MCC CPU-Intel Xeon Gold 6438Y+-32Core | EOM |
| 4102Y047 | X86 series-FCLGA4677-2000MHz-1.6V/1.83V-64bit-205000mW-Sapphire Rapids MCC CPU-Intel Xeon Gold 5420+-28Core | EOM |
| 4102Y049 | X86 series-FCLGA4677-2000MHz-1.6V/1.83V-64bit-165000mW-Sapphire Rapids MCC CPU-Intel Xeon Silver 4416+-20Core | EOM |
| 4102Y050 | X86 series-FCLGA4677-2000MHz-1.6V/1.83V-64bit-150000mW-Sapphire Rapids MCC CPU-Intel Xeon Silver 4410Y-12Core | EOM |
| 4102Y051 | X86 series-FCLGA4677-2200MHz-1.6V/1.83V-64bit-205000mW-Sapphire Rapids MCC CPU-Intel Xeon Gold 6438M-32Core | EOM |
| 4102Y053 | X86 series-FCLGA4677-2100MHz-1.6V/1.83V-64bit-185000mW-Sapphire Rapids MCC CPU-Intel Xeon Gold 6418H-24Core | EOM |
| 4102Y059 | X86 series-FCLGA4677-1800MHz-1.6V/1.83V-64bit-165000mW-Sapphire Rapids MCC CPU-Intel Xeon Gold 5418N-24Core | EOM |
| 4102Y061 | X86 series-FCLGA4677-3100MHz-1.6V/1.83V-64bit-350000mW-Sapphire Rapids MCC CPU-Intel Xeon Gold 6458Q-32Core | EOM |
| 4102Y062 | X86 series-FCLGA4677-2100MHz-1.6V/1.83V-64bit-185000mW-Sapphire Rapids MCC CPU-Intel Xeon Gold 5412U-24Core | EOM |
| 4102Y063 | X86 series-FCLGA4677-1800MHz-1.6V/1.83V-64bit-125000mW-Sapphire Rapids MCC CPU-Intel Xeon Bronze 3408U-8Core | EOM |
| 4102Y065 | X86 series-FCLGA4677-2700MHz-1.6V/1.83V-64bit-150000mW-Sapphire Rapids MCC CPU-Intel Xeon Silver 4410T-10Core | EOM |
| 90010339 | Liquid Manufactory Auxiliaries,Thermal Grease,X-23-7868-2D,Thermal Conductivity 3.6W/mK / 6.0W/mK,2g,Gap filling thermal conductive for customer use,1ml | Current |
| 4102Y068 | X86 series,FCLGA4677,2100MHz,1.6V/1.83V,64bit,350000mW,Sapphire Rapids HBM CPU-Intel Xeon Max 9468-48Core | Current Field replaceable |
| 4102Y070 | X86 series,FCLGA4677,2700MHz,1.6V/1.83V,64bit,350000mW,Sapphire Rapids HBM CPU-Intel Xeon Max 9462-32Core | Current Field replaceable |
| 4102Y067 | X86 series,FCLGA4677,2000MHz,1.6V/1.83V,64bit,350000mW,Sapphire Rapids HBM CPU-Intel Xeon Max 9470-52Core | Current Field replaceable |
| P/N | Description / Specification | Status |
|---|---|---|
| 0251Y062 | memory module-2288H V7-generic memory-DDR5-RDIMM-64GB-288pin-0.42ns-4800000KHz-1.1V-ECC-2Rank(4G*4bit)-overseas dedicated | Current |
| 0251Y064 | memory module-2288H V7-generic memory-DDR5-RDIMM-16GB-288pin-0.42ns-4800000KHz-1.1V-ECC-1Rank(2G*8bit)-overseas dedicated | Current |
| 0251Y112 | memory module-2288H V7-generic memory-DDR5-RDIMM-64GB-288pin-0.42ns-4800000KHz-1.1V-ECC-2Rank(4G*4bit) | Current |
| 0251Y143 | memory module-2258 V7-generic memory-DDR5-RDIMM-32GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(2G*8bit)-3-way OEM code_overseas dedicated | Current |
| 0251Y144 | memory module-2258 V7-generic memory-DDR5-RDIMM-64GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(4G*4bit)-3-way OEM code_overseas dedicated | Current |
| 0251Y145 | memory module-2258 V7-generic memory-DDR5-RDIMM-96GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(6G*4bit)-3-way OEM code_overseas dedicated | Current |
| 0251Y150 | memory module-2288H V7-generic memory-DDR5-RDIMM-16GB-288pin-0.357ns-5600000KHz-1.1V-ECC-1Rank(2G*8bit)-overseas dedicated | Current |
| 0251Y177 | memory module-2258 V7-generic memory-DDR5-RDIMM-64GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(4G*4bit)-XH-overseas dedicated | Current |
| 0251Y190 | memory module-2288H V7-generic memory-DDR5-RDIMM-16GB-288pin-0.357ns-5600000KHz-1.1V-ECC-1Rank(2G*8bit)-Samsung | Current |
| 0251Y193 | memory module-2288H V7-generic memory-DDR5-RDIMM-32GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(2G*8bit)-Samsung | Current |
| 0251Y194 | memory module-2258 V7-generic memory-DDR5-RDIMM-64GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(4G*4bit)-Samsung | Current |
| 0251Y195 | memory module-2258 V7-generic memory-DDR5-RDIMM-64GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(4G*4bit)-SK hynix | Current |
| 0251Y196 | memory module-2288H V7-generic memory-DDR5-RDIMM-64GB-288pin-0.42ns-4800000KHz-1.1V-ECC-2Rank(4G*4bit)-overseas dedicated-spec code | Current |
| 0251Y197 | memory module-2288H V7-generic memory-DDR5-RDIMM-32GB-288pin-0.42ns-4800000KHz-1.1V-ECC-2Rank(2G*8bit)-overseas dedicated-spec code | Current |
| 0251Y198 | memory module-2288H V7-generic memory-DDR5-RDIMM-16GB-288pin-0.42ns-4800000KHz-1.1V-ECC-1Rank(2G*8bit)-overseas dedicated-spec code | Current |
| 0251Y202 | memory module-2288H V7-generic memory-DDR5-RDIMM-32GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(2G*8bit)-overseas dedicated-spec code | Current |
| 0251Y203 | memory module-2288H V7-generic memory-DDR5-RDIMM-64GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(4G*4bit)-overseas dedicated-spec code | Current |
| 0251Y220 | memory module-Fusion Sever-generic memory-DDR5-RDIMM-64GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(4G*4bit) | Current |
| 0251Y226 | memory module-2288H V7-generic memory-DDR5-RDIMM-128GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(8G*4bit)-SDP-overseas dedicated | Current |
| 0251Y244 | memory module-2258 V7-generic memory-DDR5-RDIMM-64GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(4G*4bit)-CB1C-CXMT G3 | Current |
| 0251Y273 | memory module-2288H V7-generic memory-DDR5-RDIMM-64GB-288pin-0.312ns-6400000KHz-1.1V-ECC-2Rank(4G*4bit) | Current |
| 0251Y276 | memory module-2288H V7-generic memory-DDR5-RDIMM-16GB-288pin-0.357ns-5600000KHz-1.1V-ECC-1Rank(2G*8bit) | Current |
| 0251Y287 | memory module-2288H V7-M564R32-generic memory-DDR5-RDIMM-32GB-288pin-0.312ns-6400000KHz-1.1V-ECC-2Rank(2G*8bit)-overseas dedicated | Current |
| 0251Y288 | memory module-2288H V7-M564R64-generic memory-DDR5-RDIMM-64GB-288pin-0.312ns-6400000KHz-1.1V-ECC-2Rank(4G*4bit)-overseas dedicated | Current |
| 0251Y289 | memory module-2288H V7-M564R96-generic memory-DDR5-RDIMM-96GB-288pin-0.312ns-6400000KHz-1.1V-ECC-2Rank(6G*4bit)-3-way OEM code_overseas dedicated | Current |
| 0251Y290 | memory module-2288H V7-M564R128-generic memory-DDR5-RDIMM-128GB-288pin-0.312ns-6400000KHz-1.1V-ECC-2Rank(8G*4bit)-3-way OEM code_overseas dedicated | Current |
| 0251Y291 | memory module-2288H V7-M556R64-generic memory-DDR5-RDIMM-64GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(4G*4bit)-for use in China only | Current |
| 0251Y297 | memory module-2288H V7-M564R32-generic memory-DDR5-RDIMM-32GB-288pin-0.312ns-6400000KHz-1.1V-ECC-2Rank(2G*8bit)-Samsung 1bnm-Turin platform prohibited | Current |
| 0251Y300 | memory module-2258 V7-M556R64-generic memory-DDR5-RDIMM-64GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(4G*4bit)-SEA SAMSUNG 1anm | Current |
| 0251Y301 | memory module-2288H V7-M564R32-generic memory-DDR5-RDIMM-32GB-288pin-0.312ns-6400000KHz-1.1V-ECC-2Rank(2G*8bit)-Samsung 1bnm,Sea | Current |
| 0251Y305 | memory module-2288 V8-M564R64-generic memory-DDR5-RDIMM-64GB-288pin-0.312ns-6400000KHz-1.1V-ECC-2Rank(4G*4bit)-XH consumable virtual code,Intel platform dedicated | Current |
| 0251Y306 | memory module-2288 V8-M564R32-generic memory-DDR5-RDIMM-32GB-288pin-0.312ns-6400000KHz-1.1V-ECC-2Rank(2G*8bit)-XH consumable virtual code-Intel platform dedicated | Current |
| 0251Y307 | memory module-2258 V7-M556R96-generic memory-DDR5-RDIMM-96GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(6G*4bit)-XH consumable virtual code-overseas dedicated | Current |
| 0251Y314 | memory module-M556R32-DDR5 RDIMM-32GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(2G*8bit) | Current |
| 0251Y315 | memory module-2288H V7-M564R32-generic memory-DDR5-RDIMM-32GB-288pin-0.312ns-6400000KHz-1.1V-ECC-2Rank(2G*8bit)-Samsung 1bnm-Turin platform prohibited | Current |
| 0251Y316 | memory module-2258 V7-M556R64-generic memory-DDR5-RDIMM-64GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(4G*4bit)-CXMT G4-down-binned die | Current |
| 0251Y317 | memory module-2288H V7-generic memory-DDR5-RDIMM-64GB-288pin-0.312ns-6400000KHz-1.1V-ECC-2Rank(4G*4bit) | Current |
| 0251Y321 | memory module-2288H V7-generic memory-DDR5-RDIMM-64GB-288pin-0.312ns-6400000KHz-1.1V-ECC-2Rank(4G*4bit) | Current |
| 0251Y325 | memory module-2288H V7-M564R32-generic memory-DDR5-RDIMM-32GB-288pin-0.312ns-6400000KHz-1.1V-ECC-2Rank(2G*8bit)-Samsung 1bnm-Turin platform prohibited | Current |
| 0251Y326 | memory module-DDR5 RDIMM-64GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(4G*4bit) | Current |
| 0251Y344 | memory module-2258 V7-M564R64-generic memory-DDR5-RDIMM-64GB-288pin-0.312ns-6400000KHz-1.1V-ECC-2Rank(4G*4bit)-Samsung 1bnm-Turin platform prohibited | Current |
| 0251Y347 | memory module-2258 V7-M556R64-generic memory-DDR5-RDIMM-64GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(4G*4bit)-Haipu_XH | Current |
| 06200484 | generic memory-DDR5-RDIMM-64GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(4G*4bit)-HYNIX 1anm | Current |
| 0620Y006-003 | generic memory-DDR5-RDIMM-64GB-288pin-0.42ns-4800000KHz-1.1V-ECC-2Rank(4G*4bit)-Samsung 1ynm | Current |
| 0620Y006-006 | generic memory-DDR5-RDIMM-64GB-288pin-0.42ns-4800000KHz-1.1V-ECC-2Rank(4G*4bit)-3-way OEM code | Current |
| 0620Y006-023 | generic memory-DDR5-RDIMM-64GB-288pin-0.42ns-4800000KHz-1.1V-ECC-2Rank(4G*4bit)-Landun Technology customer-supplied material | Current |
| 0620Y019 | generic memory-DDR5-RDIMM-48GB-288pin-0.416ns-4800000KHz-1.1V-ECC-2Rank(3G*8bit) | Current |
| 0620Y026 | generic memory-DDR5-RDIMM-96GB-288pin-0.416ns-4800000KHz-1.1V-ECC-2Rank(6G*4bit) | Current |
| 0620Y027 | generic memory-DDR5-RDIMM-16GB-288pin-0.357ns-5600000KHz-1.1V-ECC-1Rank(2G*8bit) | Current |
| 0620Y027-002 | generic memory-DDR5-RDIMM-16GB-288pin-0.357ns-5600000KHz-1.1V-ECC-1Rank(2G*8bit)-designated-model dedicated-HYNIX 1anm | Current |
| 0620Y029 | generic memory-DDR5-RDIMM-32GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(2G*8bit) | Current |
| 0620Y029-001 | generic memory-DDR5-RDIMM-32GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(2G*8bit)-SK Hynix 1anm-designated-model dedicated | Current |
| 0620Y029-006 | generic memory-DDR5-RDIMM-32GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(2G*8bit)-CXMT G4 | Current |
| 0620Y029-016 | generic memory-DDR5-RDIMM-32GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(2G*8bit)-M321R4GA3EB2-CWMKH,customer designated | Current |
| 0620Y029-019 | generic memory-DDR5-RDIMM-32GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(2G*8bit)-CXMT G4-down-binned die | Current |
| 0620Y029-020 | generic memory-DDR5-RDIMM-32GB-288pin-0.312ns-6400000KHz-1.1V-ECC-2Rank(2G*8bit)-Samsung 1bnm-Turin platform prohibited | Current |
| 0620Y029-023 | generic memory-DDR5-RDIMM-32GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(2G*8bit)-Haipu | Current |
| 0620Y029-024 | generic memory-DDR5-RDIMM-32GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(2G*8bit)-Tigo/kingbank | Current |
| 0620Y029-029 | generic memory-DDR5-RDIMM-32GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(2G*8bit)-specific designated models-Samsung 1anm | Current |
| 0620Y030 | generic memory-DDR5-RDIMM-48GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(3G*8bit) | Current |
| 0620Y031 | generic memory-DDR5-RDIMM-64GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(4G*4bit) | Current |
| 0620Y031-004 | generic memory-DDR5-RDIMM-64GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(4G*4bit)-SK Hynix 1anm | Current |
| 0620Y031-005 | generic memory-DDR5-RDIMM-64GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(4G*4bit)-3-way OEM code_overseas dedicated | Current |
| 0620Y031-006 | generic memory-DDR5-RDIMM-64GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(4G*4bit)-XH consumable virtual code | Current |
| 0620Y031-008 | generic memory-DDR5-RDIMM-64GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(4G*4bit) | Current |
| 0620Y031-009 | generic memory-DDR5-RDIMM-64GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(4G*4bit)-Xiaohongshu designated-Hynix 1anm | Current |
| 0620Y031-012 | generic memory-DDR5-RDIMM-64GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(4G*4bit)-CXMT G4 | Current |
| 0620Y031-014 | generic memory-DDR5-RDIMM-64GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(4G*4bit)-Yuxincustomer-supplied material | Current |
| 0620Y031-016 | generic memory-DDR5-RDIMM-64GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(4G*4bit)-SK Hynix 1anm -Landun Technology customer-supplied material | Current |
| 0620Y031-019 | generic memory-DDR5-RDIMM-64GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(4G*4bit)-customer designated | Current |
| 0620Y031-024 | generic memory-DDR5-RDIMM-64GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(4G*4bit)-XH consumable virtual code-for use in China | Current |
| 0620Y031-025 | generic memory-DDR5-RDIMM-64GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(4G*4bit)-CXMT G4-down-binned die | Current |
| 0620Y031-025-P01 | generic memory-DDR5-RDIMM-64GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(4G*4bit)-CXMT G4-down-binned die | Current |
| 0620Y031-027 | generic memory-DDR5-RDIMM-64GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(4G*4bit)-Haipu | Current |
| 0620Y031-028 | generic memory-DDR5-RDIMM-64GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(4G*4bit)-Tigo/kingbank | Current |
| 0620Y031-029 | generic memory-DDR5-RDIMM-64GB-288pin-0.312ns-6400000KHz-1.1V-ECC-2Rank(4G*4bit)-Samsung 1bnm-Turin platform prohibited | Current |
| 0620Y031-038 | generic memory-DDR5-RDIMM-64GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(4G*4bit)-Sangfor customer-supplied material | Current |
| 0620Y031-039 | generic memory-DDR5-RDIMM-64GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(4G*4bit)-Samsung 1bnm-internet-designated model | Current |
| 0620Y031-A01 | generic memory-DDR5-RDIMM-64GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(4G*4bit)-SEA SAMSUNG 1anm | Current |
| 0620Y031-A09 | generic memory-DDR5-RDIMM-64GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(4G*4bit)-CXMT G4-CXMT | Current |
| 0620Y031-A19 | generic memory-DDR5-RDIMM-64GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(4G*4bit)-Hynix 1anm_HMCG94AGBRA632N_CAPITAO | Current |
| 0620Y031-A20 | generic memory-DDR5-RDIMM-64GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(4G*4bit)-Hynix 1anm_HMCG94AGBRA627N_CAPITAO | Current |
| 0620Y032 | generic memory-DDR5-RDIMM-96GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(6G*4bit) | Current |
| 0620Y032-001 | generic memory-DDR5-RDIMM-96GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(6G*4bit)-SAMSUNG 1anm | Current |
| 0620Y032-005 | generic memory-DDR5-RDIMM-96GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(6G*4bit)-SK Hynix 1anm-designated-model dedicated | Current |
| 0620Y032-012 | generic memory-DDR5-RDIMM-96GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(6G*4bit)-Haipu | Current |
| 0620Y033 | generic memory-DDR5-RDIMM-128GB-288pin-0.357ns-5600000KHz-1.1V-ECC-4Rank(4G*4bit)-3DS | Current |
| 0620Y035 | generic memory-DDR5-RDIMM-128GB-288pin-0.312ns-6400000KHz-1.1V-ECC-2Rank(8G*4bit) | Current |
| 0620Y038 | generic memory-DDR5-RDIMM-16GB-288pin-0.312ns-6400000KHz-1.1V-ECC-1Rank(2G*8bit) | Current |
| 0620Y040 | generic memory-DDR5-RDIMM-32GB-288pin-0.312ns-6400000KHz-1.1V-ECC-2Rank(2G*8bit) | Current |
| 0620Y040-003 | generic memory-DDR5-RDIMM-32GB-288pin-0.312ns-6400000KHz-1.1V-ECC-2Rank(2G*8bit)-overseas dedicated | Current |
| 0620Y040-008 | generic memory-DDR5-RDIMM-32GB-288pin-0.312ns-6400000KHz-1.1V-ECC-2Rank(2G*8bit)-CXMT | Current |
| 0620Y040-A08 | generic memory-DDR5-RDIMM-32GB-288pin-0.312ns-6400000KHz-1.1V-ECC-2Rank(2G*8bit)-Samsung 1bnm,Sea | Current |
| 0620Y042 | generic memory-DDR5-RDIMM-64GB-288pin-0.312ns-6400000KHz-1.1V-ECC-2Rank(4G*4bit) | Current |
| 0620Y042-006 | generic memory-DDR5-RDIMM-64GB-288pin-0.312ns-6400000KHz-1.1V-ECC-2Rank(4G*4bit)-overseas dedicated | Current |
| 0620Y042-011 | generic memory-DDR5-RDIMM-64GB-288pin-0.312ns-6400000KHz-1.1V-ECC-2Rank(4G*4bit)-CXMT | Current |
| 0620Y042-A08 | generic memory-DDR5-RDIMM-64GB-288pin-0.312ns-6400000KHz-1.1V-ECC-2Rank(4G*4bit)-Samsung 1bnm,SEA | Current |
| 0620Y043 | generic memory-DDR5-RDIMM-96GB-288pin-0.312ns-6400000KHz-1.1V-ECC-2Rank(6G*4bit) | Current |
| 0620Y043-011 | generic memory-DDR5-RDIMM-96GB-288pin-0.312ns-6400000KHz-1.1V-ECC-2Rank(6G*4bit)-CXMT | Current |
| 0620Y044 | generic memory-DDR5-RDIMM-256GB-288pin-0.312ns-6400000KHz-1.1V-ECC-4Rank(8G*4bit)-3DS | Current |
| 0620Y061 | generic memory-DDR5-RDIMM-128GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(8G*4bit)-SDP | Current |
| 0620Y061-002 | generic memory-DDR5-RDIMM-128GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(8G*4bit)-SDP-3-way OEM code_overseas dedicated | Current |
| 0620Y068 | generic memory-DDR5-RDIMM-16GB-288pin-0.42ns-4800000KHz-1.1V-ECC-1Rank(2G*8bit)-spec code | Current |
| 0620Y069 | generic memory-DDR5-RDIMM-32GB-288pin-0.42ns-4800000KHz-1.1V-ECC-2Rank(2G*8bit)-spec code | Current |
| 0620Y070 | generic memory-DDR5-RDIMM-64GB-288pin-0.42ns-4800000KHz-1.1V-ECC-2Rank(4G*4bit)-spec code | Current |
| 0620Y071 | generic memory-DDR5-RDIMM-32GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(2G*8bit)-spec code | Current |
| 0620Y072 | generic memory-DDR5-RDIMM-64GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(4G*4bit)-spec code | Current |
| 0620Y076 | generic memory-DDR5-RDIMM-16GB-288pin-0.357ns-5600000KHz-1.1V-ECC-1Rank(2G*8bit)-spec code | Current |
| 0251Y063 | memory module-2288H V7-generic memory-DDR5-RDIMM-32GB-288pin-0.42ns-4800000KHz-1.1V-ECC-2Rank(2G*8bit)-overseas dedicated | EOM |
| 0251Y125 | memory module-2288H V7-generic memory-DDR5-RDIMM-64GB-288pin-0.42ns-4800000KHz-1.1V-ECC-2Rank(4G*4bit) | EOS |
| 0251Y126 | memory module-2288H V7-generic memory-DDR5-RDIMM-128GB-288pin-0.42ns-4800000KHz-1.1V-ECC-4Rank(4G*4bit)-3DS | EOS |
| 0251Y129 | memory module-2288H V7-generic memory-DDR5-RDIMM-128GB-288pin-0.42ns-4800000KHz-1.1V-ECC-4Rank(4G*4bit)-3DS-domestic&overseas general | EOP |
| 0251Y146 | memory module-2288H V7-generic memory-DDR5-RDIMM-16GB-288pin-0.42ns-4800000KHz-1.1V-ECC-1Rank(2G*8bit)-0620Y003-XH-JWY SAMSUNG 1ynm | EOM |
| 0251Y174 | memory module-2288H V7-generic memory-DDR5-RDIMM-64GB-288pin-0.42ns-4800000KHz-1.1V-ECC-2Rank(4G*4bit)-XH | EOM |
| 06200484-001 | generic memory-DDR5-RDIMM-64GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(4G*4bit)-KunLun dedicated-Samsung 1anm | EOM |
| 0620Y003 | generic memory-DDR5-RDIMM-16GB-288pin-0.42ns-4800000KHz-1.1V-ECC-1Rank(2G*8bit) | EOM |
| 0620Y003-001 | generic memory-DDR5-RDIMM-16GB-288pin-0.42ns-4800000KHz-1.1V-ECC-1Rank(2G*8bit)-designated-model dedicated-Samsung 1ynm | EOM |
| 0620Y003-002 | generic memory-DDR5-RDIMM-16GB-288pin-0.42ns-4800000KHz-1.1V-ECC-1Rank(2G*8bit)-designated-model dedicated-Hynix 1anm | EOM |
| 0620Y005 | generic memory-DDR5-RDIMM-32GB-288pin-0.42ns-4800000KHz-1.1V-ECC-2Rank(2G*8bit) | EOM |
| 0620Y005-001 | generic memory-DDR5-RDIMM-32GB-288pin-0.42ns-4800000KHz-1.1V-ECC-2Rank(2G*8bit)-designated-model dedicated-Samsung 1ynm | EOM |
| 0620Y005-002 | generic memory-DDR5-RDIMM-32GB-288pin-0.42ns-4800000KHz-1.1V-ECC-2Rank(2G*8bit)-designated-model dedicated-Hynix 1anm | EOM |
| 0620Y005-005 | generic memory-DDR5-RDIMM-32GB-288pin-0.42ns-4800000KHz-1.1V-ECC-2Rank(2G*8bit) | EOM |
| 0620Y006 | generic memory-DDR5-RDIMM-64GB-288pin-0.42ns-4800000KHz-1.1V-ECC-2Rank(4G*4bit) | EOM |
| 0620Y006-001 | generic memory-DDR5-RDIMM-64GB-288pin-0.42ns-4800000KHz-1.1V-ECC-2Rank(4G*4bit)-designated-model dedicated-Samsung 1ynm | EOM |
| 0620Y006-002 | generic memory-DDR5-RDIMM-64GB-288pin-0.42ns-4800000KHz-1.1V-ECC-2Rank(4G*4bit)-designated-model dedicated-Hynix 1anm | EOM |
| 0620Y006-011 | generic memory-DDR5-RDIMM-64GB-288pin-0.42ns-4800000KHz-1.1V-ECC-2Rank(4G*4bit)-Hynix 1anm | EOM |
| 0620Y009 | generic memory-DDR5-RDIMM-128GB-288pin-0.42ns-4800000KHz-1.1V-ECC-4Rank(4G*4bit)-3DS | EOM |
| 0620Y009-001 | generic memory-DDR5-RDIMM-128GB-288pin-0.42ns-4800000KHz-1.1V-ECC-4Rank(4G*4bit)-3DS-Samsung 1ynm | EOM |
| 0620Y010 | generic memory-DDR5-RDIMM-256GB-288pin-0.42ns-4800000KHz-1.1V-ECC-8Rank(8G*4bit)-3DS | EOM |
| 0620Y027-001 | generic memory-DDR5-RDIMM-16GB-288pin-0.357ns-5600000KHz-1.1V-ECC-1Rank(2G*8bit)-designated-model dedicated-Samsung 1anm | EOM |
| 0620Y027-005 | generic memory-DDR5-RDIMM-16GB-288pin-0.357ns-5600000KHz-1.1V-ECC-1Rank(2G*8bit)-designated-model dedicated SAMSUNG 1bnm | EOM |
| 0620Y029-002 | generic memory-DDR5-RDIMM-32GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(2G*8bit)-designated-model dedicated-Samsung 1anm | EOM |
| 0620Y029-018 | generic memory-DDR5-RDIMM-32GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(2G*8bit)-Sangfor customer-supplied material-Samsung 1anm | EOM |
| 0620Y031-001 | generic memory-DDR5-RDIMM-64GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(4G*4bit)-Samsung 1anm | EOM |
| 0620Y031-003 | generic memory-DDR5-RDIMM-64GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(4G*4bit)-SAMSUNG 1anm | EOM |
| 0620Y031-017 | generic memory-DDR5-RDIMM-64GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(4G*4bit)-SAMSUNG 1anm-Landun Technology customer-supplied material | EOM |
| 0620Y031-032 | generic memory-DDR5-RDIMM-64GB-288pin-0.357ns-5600000KHz-1.1V-ECC-2Rank(4G*4bit)-specific designated models-Samsung 1anm | EOM |
| P/N | Description / Specification | Status |
|---|---|---|
| 0254Y057 | generic drive module-Servers-generic drive-600GB-SAS 12Gb/s-10000rpm-2.5inch-128MB and above-hot-swap-internal-2.5 inch bracket-V7 server dedicated | Current |
| 0254Y058 | generic drive module-Servers-generic drive-600GB-SAS 12Gb/s-10000rpm-2.5inch-128MB and above-hot-swap-internal-3.5 inch bracket-V7 server dedicated | Current |
| 0254Y059 | generic drive module-Servers-generic drive-1200GB-SAS 12Gb/s-10000rpm-2.5inch-128MB and above-hot-swap-internal-2.5 inch bracket-V7 server dedicated | Current |
| 0254Y060 | generic drive module-Servers-generic drive-1200GB-SAS 12Gb/s-10000rpm-2.5inch-128MB and above-hot-swap-internal-3.5 inch bracket-V7 server dedicated | Current |
| 0254Y061 | generic drive module-Servers-generic drive-1800GB-SAS 12Gb/s-10000rpm-2.5inch-128MB-hot-swap-internal-2.5 inch bracket-V7 server dedicated | Current |
| 0254Y062 | generic drive module-Servers-generic drive-1800GB-SAS 12Gb/s-10000rpm-2.5inch-128MB-hot-swap-internal-3.5 inch bracket-V7 server dedicated | Current |
| 0254Y063 | generic drive module-Servers-generic drive-2400GB-SAS 12Gb/s-10000rpm-2.5inch-256MB-hot-swap-internal-2.5 inch bracket-V7 server dedicated | Current |
| 0254Y064 | generic drive module-Servers-generic drive-2400GB-SAS 12Gb/s-10000rpm-2.5inch-256MB-hot-swap-internal-3.5 inch bracket-V7 server dedicated | Current |
| 0254Y065 | generic drive module-Servers-generic drive-4000GB-SATA 6.0Gb/s-7.2K rpm-3.5inch-128MB or above-hot-swap-internal-3.5 inch bracket-V7 server dedicated | Current |
| 0254Y067 | generic drive module-Servers-generic drive-8000GB-SATA 6.0Gb/s-7.2K rpm-3.5inch-128MB or above-hot-swap-internal-3.5 inch bracket-V7 server dedicated | Current |
| 0254Y069 | generic drive module-Servers-generic drive-12TB-SATA 6.0Gb/s-7.2K rpm-3.5inch-256MB-hot-swap-internal-3.5 inch bracket-V7 server dedicated | Current |
| 0254Y071 | generic drive module-Servers-generic drive-16TB-SATA 6.0Gb/s-7.2K rpm-3.5 inch-hot-swap-internal-3.5 inch bracket-V7 server dedicated | Current |
| 0254Y072 | generic drive module-Servers-generic drive-18TB-SATA 6.0Gb/s-7.2K rpm-3.5 inch-hot-swap-internal-3.5 inch bracket-V7 server dedicated | Current |
| 0254Y096 | generic drive module-Servers-generic drive-20TB-SATA 6.0Gb/s-7.2K rpm-3.5 inch-hot-swap-internal-3.5 inch bracket-V7 server dedicated | Current |
| 0254Y356 | generic drive module-Servers-generic drive-2400GB-SAS 12Gb/s-10000rpm-2.5inch-256MB and above-hot-swap-internal-2.5 inch bracket-V7 server dedicated-Seagate dedicated | Current |
| 0254Y357 | generic drive module-Servers-generic drive-2400GB-SAS 12Gb/s-10000rpm-2.5inch-256MB-hot-swap-internal-3.5 inch bracket-V7 server dedicated-Seagate dedicated | Current |
| 0254Y358 | generic drive module-Servers-generic drive-2400GB-SAS 12Gb/s-10000rpm-2.5inch-128MB-hot-swap-internal-2.5 inch bracket-V7 server dedicated-Toshiba dedicated | Current |
| 0254Y359 | generic drive module-Servers-generic drive-2400GB-SAS 12Gb/s-10000rpm-2.5inch-256MB-hot-swap-internal-3.5 inch bracket-V7 server dedicated-Toshiba dedicated | Current |
| 0254Y364 | generic drive module-Servers-generic drive-24TB-SATA 6.0Gb/s-7.2K rpm-3.5 inch-hot-swap-internal-3.5 inch bracket-V7 dedicated | Current |
| 0254Y369 | generic drive module-Servers-generic drive-600GB-SAS 12Gb/s-10000rpm-2.5inch-128MB and above-hot-swap-internal-2.5 inch bracket-V7 server dedicated-Seagate dedicated | Current |
| 0254Y370 | generic drive module-Servers-generic drive-600GB-SAS 12Gb/s-10000rpm-2.5inch-128MB and above-hot-swap-internal-2.5 inch bracket-V7 server dedicated-Toshiba dedicated | Current |
| 0254Y442 | generic drive module-Servers-generic drive-20TB-SATA 6.0Gb/s-7.2K rpm-3.5 inch-hot-swap-internal-3.5 inch bracket-V7 dedicated-Toshiba-customer designated | Current |
| 0254Y470 | generic drive module-Servers-generic drive-8000GB-SATA 6.0Gb/s-7.2K rpm-3.5inch-128MB or above-hot-swap-internal-3.5 inch bracket-SEAGATE-V7 dedicated | Current |
| 0254Y496 | generic drive module-Servers-generic drive-8000GB-SATA 6.0Gb/s-7.2K rpm-3.5inch-128MB or above-hot-swap-internal-3.5 inch bracket-WD-V7 dedicated | Current |
| 0254Y512 | generic drive module-Servers-generic drive-4000GB-SATA 6.0Gb/s-7.2K rpm-3.5inch-128MB or above-hot-swap-internal-3.5 inch bracket-V7 dedicated-spec code | Current |
| 0254Y514 | generic drive module-Servers-generic drive-8000GB-SATA 6.0Gb/s-7.2K rpm-3.5inch-128MB or above-hot-swap-internal-3.5 inch bracket-V7 dedicated-spec code | Current |
| 0254Y516 | generic drive module-Servers-generic drive-12TB-SATA 6.0Gb/s-7.2K rpm-3.5inch-256MB-hot-swap-internal-3.5 inch bracket-V7 dedicated-spec code | Current |
| 0254Y518 | generic drive module-Servers-generic drive-16TB-SATA 6.0Gb/s-7.2K rpm-3.5inch-hot-swap-internal-3.5 inch bracket-V7 dedicated-spec code | Current |
| 0254Y520 | generic drive module-Servers-generic drive-18TB-SATA 6.0Gb/s-7.2K rpm-3.5inch-hot-swap-internal-3.5 inch bracket-V7 dedicated-spec code | Current |
| 0254Y522 | generic drive module-Servers-generic drive-20TB-SATA 6.0Gb/s-7.2K rpm-3.5inch-hot-swap-internal-3.5 inch bracket-V7 dedicated-spec code | Current |
| 0254Y533 | generic drive module-Servers-generic drive-600GB-SAS 12Gb/s-10000rpm-2.5inch-128MB and above-hot-swap-internal-2.5 inch bracket-V7 dedicated-spec code | Current |
| 0254Y539 | generic drive module-Servers-generic drive-2400GB-SAS 12Gb/s-10000rpm-2.5inch-256MB-hot-swap-internal-2.5 inch bracket-V7 dedicated-spec code | Current |
| 0254Y540 | generic drive module-Servers-generic drive-2400GB-SAS 12Gb/s-10000rpm-2.5inch-256MB-hot-swap-internal-3.5 inch bracket-V7 dedicated-spec code | Current |
| 0254Y691 | generic drive module-Servers-generic drive-20TB-SATA 6.0Gb/s-7.2K rpm-3.5 inch-hot-swap-internal-3.5 inch bracket-designated-model dedicated-Summit V7 server dedicated | Current |
| 0254Y693 | generic drive module-Servers-generic drive-16000GB-SATA 6.0Gb/s-7.2K rpm-3.5inch-256MB-hot-swap-internal-3.5 inch bracket-designated-model dedicated-Summit V7 server dedicated | Current |
| 0254Y696 | generic drive module-Servers-generic drive-4000GB-SATA 6.0Gb/s-7.2K rpm-3.5inch-128MB or above-hot-swap-internal-3.5 inch bracket-Seagate V7 server dedicated | Current |
| 0254Y697 | generic drive module-Servers-generic drive-4000GB-SATA 6.0Gb/s-7.2K rpm-3.5inch-128MB or above-hot-swap-internal-3.5 inch bracket-WD V7 server dedicated | Current |
| 0254Y700 | generic drive module-Servers-generic drive-600GB-SAS 12Gb/s-10000rpm-2.5inch-128MB and above-hot-swap-internal-3.5 inch bracket-V7 server dedicated-Seagate dedicated | Current |
| 0254Y701 | generic drive module-Servers-generic drive-600GB-SAS 12Gb/s-10000rpm-2.5inch-128MB and above-hot-swap-internal-3.5 inch bracket-V7 dedicated-spec code | Current |
| 0254Y702 | generic drive module-Servers-generic drive-600GB-SAS 12Gb/s-10000rpm-2.5inch-128MB and above-hot-swap-internal-3.5 inch bracket-V7 server dedicated-Toshiba dedicated | Current |
| 0254Y704 | generic drive module-Servers-generic drive-1200GB-SAS 12Gb/s-10000rpm-2.5inch-128MB and above-hot-swap-internal-2.5 inch bracket-V7 dedicated-spec code | Current |
| 0254Y705 | generic drive module-Servers-generic drive-1200GB-SAS 12Gb/s-10000rpm-2.5inch-128MB and above-hot-swap-internal-3.5 inch bracket-V7 dedicated-spec code | Current |
| 0254Y706 | generic drive module-Servers-generic drive-1800GB-SAS 12Gb/s-10000rpm-2.5inch-128MB and above-hot-swap-internal-2.5 inch bracket-V7 dedicated-spec code | Current |
| 0254Y707 | generic drive module-Servers-generic drive-1800GB-SAS 12Gb/s-10000rpm-2.5inch-128MB and above-hot-swap-internal-3.5 inch bracket-V7 dedicated-spec code | Current |
| 0254Y708 | generic drive module-Servers-generic drive-1200GB-SAS 12Gb/s-10000rpm-2.5inch-128MB and above-hot-swap-internal-3.5 inch bracket-V7 server dedicated-Seagate dedicated | Current |
| 0254Y709 | generic drive module-Servers-generic drive-1200GB-SAS 12Gb/s-10000rpm-2.5inch-128MB and above-hot-swap-internal-3.5 inch bracket-V7 server dedicated-Toshiba dedicated | Current |
| 0254Y710 | generic drive module-Servers-generic drive-1200GB-SAS 12Gb/s-10000rpm-2.5inch-128MB and above-hot-swap-internal-2.5 inch bracket-V7 server dedicated-Seagate dedicated | Current |
| 0254Y711 | generic drive module-Servers-generic drive-1200GB-SAS 12Gb/s-10000rpm-2.5inch-128MB and above-hot-swap-internal-2.5 inch bracket-V7 server dedicated-Toshiba dedicated | Current |
| 0254Y712 | generic drive module-Servers-generic drive-1800GB-SAS 12Gb/s-10000rpm-2.5inch-128MB and above-hot-swap-internal-3.5 inch bracket-V7 server dedicated-Seagate dedicated | Current |
| 0254Y713 | generic drive module-Servers-generic drive-1800GB-SAS 12Gb/s-10000rpm-2.5inch-128MB and above-hot-swap-internal-3.5 inch bracket-V7 server dedicated-Toshiba dedicated | Current |
| 0254Y714 | generic drive module-Servers-generic drive-1800GB-SAS 12Gb/s-10000rpm-2.5inch-128MB and above-hot-swap-internal-2.5 inch bracket-V7 server dedicated-Seagate dedicated | Current |
| 0254Y715 | generic drive module-Servers-generic drive-1800GB-SAS 12Gb/s-10000rpm-2.5inch-128MB and above-hot-swap-internal-2.5 inch bracket-V7 server dedicated-Toshiba dedicated | Current |
| 0254Y795 | generic drive module-Servers-generic drive-30TB-SATA 6.0Gb/s-7.2K rpm-3.5 inch-hot-swap-internal-3.5 inch bracket-V7 server dedicated | Current |
| 0254Y804 | generic drive module-Servers-generic drive-24TB-SATA 6.0Gb/s-7.2K rpm-3.5 inch-hot-swap-internal-3.5 inch bracket-V7 dedicated-Toshiba-customer designated | Current |
| 0254Y852 | generic drive module-Servers-generic drive-8000GB-SATA 6.0Gb/s-7.2K rpm-3.5inch-256MB-hot-swap-internal-3.5 inch bracket-WDC Vela-A1-V7 dedicated | Current |
| 0254Y888 | generic drive module-Servers-generic drive-20000GB-NL SAS 12Gb/s-7200rpm-3.5inch-256MB-hot-swap-internal-3.5 inch bracket-Seagate Summit V7 server dedicated | Current |
| 0254Y948 | generic drive module-Servers-generic drive-12000GB-NL SAS 12Gb/s-7200rpm-3.5inch-256MB-hot-swap-internal-3.5 inch bracket-Paris-CP V7 server dedicated | Current |
| 0254Y949 | generic drive module-Servers-generic drive-16000GB-NL SAS 12.0Gb/s-7200rpm-3.5inch-256MB-hot-swap-internal-3.5 inch bracket-Paris-CP V7 dedicated | Current |
| 0254Y950 | generic drive module-Servers-generic drive-20000GB-NL SAS 12Gb/s-7200rpm-3.5inch-256MB-hot-swap-internal-3.5 inch bracket-Paris-CP V7 server dedicated | Current |
| 0255Y347 | SSD module-Servers-SSD-1920GB-SATA 6Gb/s-mixed read-write-PM897 series-2.5 inch(3.5 inch bracket)-V7 dedicated | Current |
| 0255Y417 | SSD module-Servers-SSD-480GB-SATA 6Gb/s-read-intensive-PM893 series-2.5 inch(2.5 inch bracket)-V7 dedicated | Current |
| 0255Y418 | SSD module-Servers-SSD-480GB-SATA 6Gb/s-read-intensive-PM893 series-2.5 inch(3.5 inch bracket)-V7 dedicated | Current |
| 0255Y419 | SSD module-Servers-SSD-960GB-SATA 6Gb/s-read-intensive-PM893 series-2.5 inch(2.5 inch bracket)-V7 dedicated | Current |
| 0255Y420 | SSD module-Servers-SSD-960GB-SATA 6Gb/s-read-intensive-PM893 series-2.5 inch(3.5 inch bracket)-V7 dedicated | Current |
| 0255Y421 | SSD module-Servers-SSD-1920GB-SATA 6Gb/s-read-intensive-PM893 series-2.5 inch(2.5 inch bracket)-V7 dedicated | Current |
| 0255Y422 | SSD module-Servers-SSD-1920GB-SATA 6Gb/s-read-intensive-PM893 series-2.5 inch(3.5 inch bracket)-V7 dedicated | Current |
| 0255Y423 | SSD module-Servers-SSD-3840GB-SATA 6Gb/s-read-intensive-PM893 series-2.5 inch(2.5 inch bracket)-V7 dedicated | Current |
| 0255Y424 | SSD module-Servers-SSD-3840GB-SATA 6Gb/s-read-intensive-PM893 series-2.5 inch(3.5 inch bracket)-V7 dedicated | Current |
| 0255Y427 | SSD module-Servers-SSD-480GB-SATA 6Gb/s-mixed read-write-PM897 series-2.5 inch(2.5 inch bracket)-V7 dedicated | Current |
| 0255Y428 | SSD module-Servers-SSD-480GB-SATA 6Gb/s-mixed read-write-PM897 series-2.5 inch(3.5 inch bracket)-V7 dedicated | Current |
| 0255Y429 | SSD module-Servers-SSD-960GB-SATA 6Gb/s-mixed read-write-PM897 series-2.5 inch(2.5 inch bracket)-V7 dedicated | Current |
| 0255Y430 | SSD module-Servers-SSD-960GB-SATA 6Gb/s-mixed read-write-PM897 series-2.5 inch(3.5 inch bracket)-V7 dedicated | Current |
| 0255Y431 | SSD module-Servers-SSD-1920GB-SATA 6Gb/s-mixed read-write-PM897 series-2.5 inch(2.5 inch bracket)-V7 dedicated | Current |
| 0255Y432 | SSD module-Servers-SSD-3840GB-SATA 6Gb/s-mixed read-write-PM897 series-2.5 inch(2.5 inch bracket)-V7 dedicated | Current |
| 0255Y433 | SSD module-Servers-SSD-3840GB-SATA 6Gb/s-mixed read-write-PM897 series-2.5 inch(3.5 inch bracket)-V7 dedicated | Current |
| 0255YACT | SSD module-Servers-SSD-480GB-SATA 6Gb/s-mixed read-write-PM897a series-2.5 inch(2.5 inch bracket)-V7 dedicated | Current |
| 0255YACU | SSD module-Servers-SSD-480GB-SATA 6Gb/s-mixed read-write-PM897a series-2.5 inch(3.5 inch bracket)-V7 dedicated | Current |
| 0255YACW | SSD module-Servers-SSD-1920GB-SATA 6Gb/s-mixed read-write-PM897a series-2.5 inch(2.5 inch bracket)-V7 dedicated | Current |
| 0255YACX | SSD module-Servers-SSD-1920GB-SATA 6Gb/s-mixed read-write-PM897a series-2.5 inch(3.5 inch bracket)-V7 dedicated | Current |
| 0255YACY | SSD module-Servers-SSD-960GB-SATA 6Gb/s-mixed read-write-PM897a series-2.5 inch(2.5 inch bracket)-V7 dedicated | Current |
| 0255YADA | SSD module-Servers-SSD-960GB-SATA 6Gb/s-mixed read-write-PM897a series-2.5 inch(3.5 inch bracket)-V7 dedicated | Current |
| 0255YADB | SSD module-Servers-SSD-3840GB-SATA 6Gb/s-mixed read-write-PM897a series-2.5 inch(2.5 inch bracket)-V7 dedicated | Current |
| 0255YADH | SSD module-Servers-SSD-3840GB-SATA 6Gb/s-mixed read-write-PM897a series-2.5 inch(3.5 inch bracket)-V7 dedicated | Current |
| 0255YADJ | SSD module-Servers-SSD-480GB-SATA 6Gb/s-read-intensive-PM893a series-2.5 inch(2.5 inch bracket)-V7 dedicated | Current |
| 0255YADK | SSD module-Servers-SSD-480GB-SATA 6Gb/s-read-intensive-PM893a series-2.5 inch(3.5 inch bracket)-V7 dedicated | Current |
| 0255YADL | SSD module-Servers-SSD-960GB-SATA 6Gb/s-read-intensive-PM893a series-2.5 inch(2.5 inch bracket)-V7 dedicated | Current |
| 0255YADM | SSD module-Servers-SSD-960GB-SATA 6Gb/s-read-intensive-PM893a series-2.5 inch(3.5 inch bracket)-V7 dedicated | Current |
| 0255YADN | SSD module-Servers-SSD-1920GB-SATA 6Gb/s-read-intensive-PM893a series-2.5 inch(2.5 inch bracket)-V7 dedicated | Current |
| 0255YADP | SSD module-Servers-SSD-1920GB-SATA 6Gb/s-read-intensive-PM893a series-2.5 inch(3.5 inch bracket)-V7 dedicated | Current |
| 0255YADQ | SSD module-Servers-SSD-3840GB-SATA 6Gb/s-read-intensive-PM893a series-2.5 inch(2.5 inch bracket)-V7 dedicated | Current |
| 0255YADR | SSD module-Servers-SSD-3840GB-SATA 6Gb/s-read-intensive-PM893a series-2.5 inch(3.5 inch bracket)-V7 dedicated | Current |
| 0255YAWN | SSD module-Servers-SSD-480GB-SATA 6Gb/s-read-intensive-SSSTC-ER3-CD series-2.5 inch(3.5 inch bracket)-V7 dedicated | Current |
| 0255YAWP | SSD module-Servers-SSD-480GB-SATA 6Gb/s-read-intensive-ER3 series-2.5 inch(2.5 inch bracket)-V7 dedicated | Current |
| 0255YAWQ | SSD module-Servers-SSD-960GB-SATA 6Gb/s-read-intensive-ER3 series-2.5 inch(2.5 inch bracket)-V7 dedicated | Current |
| 0255YAWR | SSD module-Servers-SSD-960GB-SATA 6Gb/s-read-intensive-SSSTC-ER3-CD series-2.5 inch(3.5 inch bracket)-V7 dedicated | Current |
| 0255YAWS | SSD module-Servers-SSD-1920GB-SATA 6Gb/s-read-intensive-ER3 series-2.5 inch(2.5 inch bracket)-V7 dedicated | Current |
| 0255YAWT | SSD module-Servers-SSD-1920GB-SATA 6Gb/s-read-intensive-SSSTC-ER3-CD series-2.5 inch(3.5 inch bracket)-V7 dedicated | Current |
| 0255YAWU | SSD module-Servers-SSD-3840GB-SATA 6Gb/s-read-intensive-ER3 series-2.5 inch(2.5 inch bracket)-V7 dedicated | Current |
| 0255YAWV | SSD module-Servers-SSD-3840GB-SATA 6Gb/s-read-intensive-SSSTC-ER3-CD series-2.5 inch(3.5 inch bracket)-V7 dedicated | Current |
| 0255YAYB | SSD module-Servers-SSD-480GB-SATA 6Gb/s-read-intensive-PM893 series-2.5 inch(2.5 inch bracket)-V7 dedicated-SED encrypted | Current |
| 0255YAYC | SSD module-Servers-SSD-480GB-SATA 6Gb/s-read-intensive-PM893 series-2.5 inch(3.5 inch bracket)-V7 dedicated-SED encrypted | Current |
| 0255YAYD | SSD module-Servers-SSD-960GB-SATA 6Gb/s-read-intensive-PM893 series-2.5 inch(2.5 inch bracket)-V7 dedicated-SED encrypted | Current |
| 0255YAYE | SSD module-Servers-SSD-960GB-SATA 6Gb/s-read-intensive-PM893 series-2.5 inch(3.5 inch bracket)-V7 dedicated-SED encrypted | Current |
| 0255YBLB | SSD module-Servers-SSD-7680GB-SAS 24Gb/s-read-intensive-PM1653 series-2.5 inch(2.5 inch bracket)-V7 dedicated-self-encrypting drive SED | Current |
| 0255YBLD | SSD module-Servers-SSD-3840GB-SAS 24Gb/s-read-intensive-PM1653 series-2.5 inch(2.5 inch bracket)-V7 dedicated-self-encrypting drive SED | Current |
| 0255YBLG | SSD module-Servers-SSD-1920GB-SAS 24Gb/s-read-intensive-PM1653 series-2.5 inch(2.5 inch bracket)-V7 dedicated-self-encrypting drive SED | Current |
| 0255YBLJ | SSD module-Servers-SSD-960GB-SAS 24Gb/s-read-intensive-PM1653 series-2.5 inch(2.5 inch bracket)-V7 dedicated-self-encrypting drive SED | Current |
| 0255YBMX | SSD module-Servers-SSD-480GB-SATA 6Gb/s-read-intensive-2.5 inch(2.5 inch bracket)-V7 dedicated-spec code | Current |
| 0255YBMX-002 | SSD module-Servers-SSD-480GB-SATA 6Gb/s-read-intensive-S4520 series-2.5 inch(2.5 inch bracket)-V7 dedicated-Solidigm | Current |
| 0255YBMY | SSD module-Servers-SSD-480GB-SATA 6Gb/s-read-intensive-2.5 inch(3.5 inch bracket)-V7 dedicated-spec code | Current |
| 0255YBMY-004 | SSD module-Servers-SSD-480GB-SATA 6Gb/s-read-intensive-S4520 series-2.5 inch(3.5 inch bracket)-V7 dedicated-Solidigm | Current |
| 0255YBNA | SSD module-Servers-SSD-960GB-SATA 6Gb/s-read-intensive-2.5 inch(2.5 inch bracket)-V7 dedicated-spec code | Current |
| 0255YBNA-001 | SSD module-Servers-SSD-960GB-SATA 6Gb/s-read-intensive-S4520 series-2.5 inch(2.5 inch bracket)-V7 dedicated-Solidigm | Current |
| 0255YBNB | SSD module-Servers-SSD-960GB-SATA 6Gb/s-read-intensive-2.5 inch(3.5 inch bracket)-V7 dedicated-spec code | Current |
| 0255YBNB-004 | SSD module-Servers-SSD-960GB-SATA 6Gb/s-read-intensive-S4520 series-2.5 inch(3.5 inch bracket)-V7 dedicated-Solidigm | Current |
| 0255YBNQ | SSD module-Servers-SSD-3840GB-SATA 6Gb/s-read-intensive-2.5 inch(2.5 inch bracket)-V7 dedicated-spec code | Current |
| 0255YBNQ-002 | SSD module-Servers-SSD-3840GB-SATA 6Gb/s-read-intensive-S4520 series-2.5 inch(2.5 inch bracket)-V7 dedicated-Solidigm | Current |
| 0255YBNQ-003 | SSD module-Servers-SSD-3840GB-SATA 6Gb/s-read-intensive-PM893 series-2.5 inch(2.5 inch bracket)-V7 dedicated-international edition | Current |
| 0255YBNR | SSD module-Servers-SSD-3840GB-SATA 6Gb/s-read-intensive-2.5 inch(3.5 inch bracket)-V7 dedicated-spec code | Current |
| 0255YBNR-002 | SSD module-Servers-SSD-3840GB-SATA 6Gb/s-read-intensive-S4520 series-2.5 inch(3.5 inch bracket)-V7 dedicated-Solidigm | Current |
| 0255YBNR-003 | SSD module-Servers-SSD-3840GB-SATA 6Gb/s-read-intensive-PM893 series-2.5 inch(3.5 inch bracket)-V7 dedicated-international edition | Current |
| 0255YBNS | SSD module-Servers-SSD-1920GB-SATA 6Gb/s-read-intensive-2.5 inch(2.5 inch bracket)-V7 dedicated-spec code | Current |
| 0255YBNS-001 | SSD module-Servers-SSD-1920GB-SATA 6Gb/s-read-intensive-S4520 series-2.5 inch(2.5 inch bracket)-V7 dedicated-Solidigm | Current |
| 0255YBNS-003 | SSD module-Servers-SSD-1920GB-SATA 6Gb/s-read-intensive-PM893 series 2.5 inch(2.5 inch bracket)-V7 dedicated-international edition | Current |
| 0255YBNT | SSD module-Servers-SSD-1920GB-SATA 6Gb/s-read-intensive-2.5 inch(3.5 inch bracket)-V7 dedicated-spec code | Current |
| 0255YBNT-004 | SSD module-Servers-SSD-1920GB-SATA 6Gb/s-read-intensive-S4520 series-2.5 inch(3.5 inch bracket)-V7 dedicated-Solidigm | Current |
| 0255YBNT-005 | SSD module-Servers-SSD-1920GB-SATA 6Gb/s-read-intensive-PM893 series-2.5 inch(3.5 inch bracket)-V7 dedicated-international edition | Current |
| 0255YCAK | SSD module-Servers-SSD-480GB-SATA 6Gb/s-mixed read-write-2.5 inch(2.5 inch bracket)-V7 dedicated-spec code | Current |
| 0255YCAK-001 | SSD module-Servers-SSD-480GB-SATA 6Gb/s-mixed read-write-S4620 series-2.5 inch(2.5 inch bracket)-V7 dedicated-Solidigm | Current |
| 0255YCAL | SSD module-Servers-SSD-480GB-SATA 6Gb/s-mixed read-write-2.5 inch(3.5 inch bracket)-V7 dedicated-spec code | Current |
| 0255YCAL-001 | SSD module-Servers-SSD-480GB-SATA 6Gb/s-mixed read-write-S4620 series-2.5 inch(3.5 inch bracket)-V7 dedicated-Solidigm | Current |
| 0255YCAM | SSD module-Servers-SSD-960GB-SATA 6Gb/s-mixed read-write-2.5 inch(2.5 inch bracket)-V7 dedicated-spec code | Current |
| 0255YCAM-001 | SSD module-Servers-SSD-960GB-SATA 6Gb/s-mixed read-write-S4620 series-2.5 inch(2.5 inch bracket)-V7 dedicated-Solidigm | Current |
| 0255YCAN | SSD module-Servers-SSD-960GB-SATA 6Gb/s-mixed read-write-2.5 inch(3.5 inch bracket)-V7 dedicated-spec code | Current |
| 0255YCAN-001 | SSD module-Servers-SSD-960GB-SATA 6Gb/s-mixed read-write-S4620 series-2.5 inch(3.5 inch bracket)-V7 dedicated-Solidigm | Current |
| 0255YCAP | SSD module-Servers-SSD-1920GB-SATA 6Gb/s-mixed read-write-2.5 inch(2.5 inch bracket)-V7 dedicated-spec code | Current |
| 0255YCAP-001 | SSD module-Servers-SSD-1920GB-SATA 6Gb/s-mixed read-write-S4620 series-2.5 inch(2.5 inch bracket)-V7 dedicated-Solidigm | Current |
| 0255YCAP-002 | SSD module-Servers-SSD-1920GB-SATA 6Gb/s-mixed read-write-PM897 series-2.5 inch(2.5 inch bracket)-V7 dedicated-international edition | Current |
| 0255YCAQ | SSD module-Servers-SSD-1920GB-SATA 6Gb/s-mixed read-write-2.5 inch(3.5 inch bracket)-V7 dedicated-spec code | Current |
| 0255YCAQ-001 | SSD module-Servers-SSD-1920GB-SATA 6Gb/s-mixed read-write-S4620 series-2.5 inch(3.5 inch bracket)-V7 dedicated-Solidigm | Current |
| 0255YCAQ-002 | SSD module-Servers-SSD-1920GB-SATA 6Gb/s-mixed read-write-PM897 series-2.5 inch(3.5 inch bracket)-V7 dedicated-international edition | Current |
| 0255YCAR | SSD module-Servers-SSD-3840GB-SATA 6Gb/s-mixed read-write-2.5 inch(2.5 inch bracket)-V7 dedicated-spec code | Current |
| 0255YCAR-001 | SSD module-Servers-SSD-3840GB-SATA 6Gb/s-mixed read-write-S4620 series-2.5 inch(2.5 inch bracket)-V7 dedicated-Solidigm | Current |
| 0255YCAR-002 | SSD module-Servers-SSD-3840GB-SATA 6Gb/s-mixed read-write-PM897 series-2.5 inch(2.5 inch bracket)-V7 dedicated-international edition | Current |
| 0255YCAS | SSD module-Servers-SSD-3840GB-SATA 6Gb/s-mixed read-write-2.5 inch(3.5 inch bracket)-V7 dedicated-spec code | Current |
| 0255YCAS-001 | SSD module-Servers-SSD-3840GB-SATA 6Gb/s-mixed read-write-S4620 series-2.5 inch(3.5 inch bracket)-V7 dedicated-Solidigm | Current |
| 0255YCAS-002 | SSD module-Servers-SSD-3840GB-SATA 6Gb/s-mixed read-write-PM897 series-2.5 inch(3.5 inch bracket)-V7 dedicated-international edition | Current |
| 0255YCDN | SSD module-Servers-SSD-1600GB-SAS 12Gb/s-mixed read-write-UH631a-Y series-2.5 inch(2.5 inch bracket)-V7 dedicated | Current |
| 0255YCDP | SSD module-Servers-SSD-1600GB-SAS 12Gb/s-mixed read-write-UH631a-Y series-2.5 inch(3.5 inch bracket)-V7 dedicated | Current |
| 0255YCMP | SSD module-Servers-SSD-1920GB-SATA 6Gb/s-read-intensive-PM893 series-2.5 inch(3.5 inch bracket)-V7 dedicated-SED encrypted | Current |
| 0255YCMQ | SSD module-Servers-SSD-1920GB-SATA 6Gb/s-read-intensive-PM893 series-2.5 inch(2.5 inch bracket)-V7 dedicated-SED encrypted | Current |
| 0255YCMT | SSD module-Servers-SSD-3840GB-SATA 6Gb/s-read-intensive-PM893 series-2.5 inch(2.5 inch bracket)-V7 dedicated-SED encrypted | Current |
| 0255YCMU | SSD module-Servers-SSD-3840GB-SATA 6Gb/s-read-intensive-PM893 series-2.5 inch(3.5 inch bracket)-V7 dedicated-SED encrypted | Current |
| 0255YCMX | SSD module-Servers-SSD-480GB-SATA 6Gb/s-mixed read-write-PM897 series-2.5 inch(2.5 inch bracket)-V7 dedicated-SED encrypted | Current |
| 0255YCMY | SSD module-Servers-SSD-480GB-SATA 6Gb/s-mixed read-write-PM897 series-2.5 inch(3.5 inch bracket)-V7 dedicated-SED encrypted | Current |
| 0255YCNC | SSD module-Servers-SSD-960GB-SATA 6Gb/s-mixed read-write-PM897 series-2.5 inch(2.5 inch bracket)-V7 dedicated-SED encrypted | Current |
| 0255YCND | SSD module-Servers-SSD-960GB-SATA 6Gb/s-mixed read-write-PM897 series-2.5 inch(3.5 inch bracket)-V7 dedicated-SED encrypted | Current |
| 0255YCNG | SSD module-Servers-SSD-1920GB-SATA 6Gb/s-mixed read-write-PM897 series-2.5 inch(3.5 inch bracket)-V7 dedicated-SED encrypted | Current |
| 0255YCNH | SSD module-Servers-SSD-1920GB-SATA 6Gb/s-mixed read-write-PM897 series-2.5 inch(2.5 inch bracket)-V7 dedicated-SED encrypted | Current |
| 0255YCNL | SSD module-Servers-SSD-3840GB-SATA 6Gb/s-mixed read-write-PM897 series-2.5 inch(2.5 inch bracket)-V7 dedicated-SED encrypted | Current |
| 0255YCNM | SSD module-Servers-SSD-3840GB-SATA 6Gb/s-mixed read-write-PM897 series-2.5 inch(3.5 inch bracket)-V7 dedicated-SED encrypted | Current |
| 0255YDUH | SSD module-Servers-SSD-480GB-SATA 6Gb/s-read-intensive-SE006 series-2.5 inch(2.5 inch bracket)-V7 dedicated | Current |
| 0255YDUJ | SSD module-Servers-SSD-480GB-SATA 6Gb/s-read-intensive-SE006 series-2.5 inch(3.5 inch bracket)-V7 dedicated | Current |
| 0255YDUM | SSD module-Servers-SSD-960GB-SATA 6Gb/s-read-intensive-SE006 series-2.5 inch(2.5 inch bracket)-V7 dedicated | Current |
| 0255YDUN | SSD module-Servers-SSD-960GB-SATA 6Gb/s-read-intensive-SE006 series-2.5 inch(3.5 inch bracket)-V7 dedicated | Current |
| 0255YDUR | SSD module-Servers-SSD-1920GB-SATA 6Gb/s-read-intensive-SE006 series-2.5 inch(2.5 inch bracket)-V7 dedicated | Current |
| 0255YDUS | SSD module-Servers-SSD-1920GB-SATA 6Gb/s-read-intensive-SE006 series-2.5 inch(3.5 inch bracket)-V7 dedicated | Current |
| 0255YDUW | SSD module-Servers-SSD-7680GB-SATA 6Gb/s-read-intensive-SE006 series-2.5 inch(2.5 inch bracket)-V7 dedicated | Current |
| 0255YDUX | SSD module-Servers-SSD-7680GB-SATA 6Gb/s-read-intensive-SE006 series-2.5 inch(3.5 inch bracket)-V7 dedicated | Current |
| 0255YDXA | SSD module-Servers-SSD-3840GB-SATA 6Gb/s-read-intensive-SE006 series-2.5 inch(2.5 inch bracket)-V7 dedicated | Current |
| 0255YDXB | SSD module-Servers-SSD-3840GB-SATA 6Gb/s-read-intensive-SE006 series-2.5 inch(3.5 inch bracket)-V7 dedicated | Current |
| 0255YESE | SSD module-Servers-SSD-960GB-SATA 6Gb/s-mixed read-write-S4620 series-2.5 inch(2.5 inch bracket)-V7 dedicated-Solidigm | Current |
| 0255YESS | SSD module-Servers-SSD-3840GB-SATA 6Gb/s-read-intensive-PM893 series-2.5 inch(2.5 inch bracket)-V7 dedicated | Current |
| 0255YEST | SSD module-Servers-SSD-3840GB-SATA 6Gb/s-read-intensive-PM893 series-2.5 inch(3.5 inch bracket)-V7 dedicated | Current |
| 0255YETE | SSD module-Servers-SSD-480GB-SATA 6Gb/s-read-intensive-SE006 series-2.5 inch(2.5 inch bracket)-V7 dedicated | Current |
| 0255YETJ | SSD module-Servers-SSD-480GB-SATA 6Gb/s-read-intensive-SE006 series-2.5 inch(3.5 inch bracket)-V7 dedicated | Current |
| 0255YETM | SSD module-Servers-SSD-3840GB-SATA 6Gb/s-mixed read-write-PM897 series-2.5 inch(2.5 inch bracket)-V7 dedicated | Current |
| 0255YETN | SSD module-Servers-SSD-3840GB-SATA 6Gb/s-mixed read-write-PM897 series-2.5 inch(3.5 inch bracket)-V7 dedicated | Current |
| 0255YETU | SSD module-Servers-SSD-480GB-SATA 6Gb/s-read-intensive-SSSTC-ER3-CD series-2.5 inch(3.5 inch bracket)-V7 dedicated | Current |
| 0255YETV | SSD module-Servers-SSD-480GB-SATA 6Gb/s-read-intensive-ER3 series-2.5 inch(2.5 inch bracket)-V7 dedicated | Current |
| 0255YEUM | SSD module-Servers-SSD-1920GB-SATA 6Gb/s-read-intensive-ER3 series-2.5 inch(2.5 inch bracket)-V7 dedicated | Current |
| 0255YEUN | SSD module-Servers-SSD-480GB-SATA 6Gb/s-read-intensive-PM893 series-2.5 inch(2.5 inch bracket)-V7 dedicated | Current |
| 0255YEUP | SSD module-Servers-SSD-1920GB-SATA 6Gb/s-read-intensive-SSSTC-ER3-CD series-2.5 inch(3.5 inch bracket)-V7 dedicated | Current |
| 0255YEUR | SSD module-Servers-SSD-480GB-SATA 6Gb/s-read-intensive-PM893 series-2.5 inch(3.5 inch bracket)-V7 dedicated | Current |
| 0255YEUY | SSD module-Servers-SSD-960GB-SATA 6Gb/s-mixed read-write-PM897 series-2.5 inch(3.5 inch bracket)-V7 dedicated | Current |
| 0255YEVC | SSD module-Servers-SSD-960GB-SATA 6Gb/s-mixed read-write-PM897 series-2.5 inch(2.5 inch bracket)-V7 dedicated | Current |
| 0255YEVR | SSD module-Servers-SSD-960GB-SATA 6Gb/s-read-intensive-SSSTC-ER3-CD series-2.5 inch(3.5 inch bracket)-V7 dedicated | Current |
| 0255YEVT | SSD module-Servers-SSD-960GB-SATA 6Gb/s-read-intensive-ER3 series-2.5 inch(2.5 inch bracket)-V7 dedicated | Current |
| 0255YEVX | SSD module-Servers-SSD-3840GB-SATA 6Gb/s-mixed read-write-S4620 series-2.5 inch(2.5 inch bracket)-V7 dedicated-Solidigm | Current |
| 0255YEWE | SSD module-Servers-SSD-3840GB-SATA 6Gb/s-mixed read-write-S4620 series-2.5 inch(3.5 inch bracket)-V7 dedicated-Solidigm | Current |
| 0255YEWK | SSD module-Servers-SSD-1920GB-SATA 6Gb/s-mixed read-write-S4620 series-2.5 inch(2.5 inch bracket)-V7 dedicated-Solidigm | Current |
| 0255YEXB | SSD module-Servers-SSD-960GB-SATA 6Gb/s-mixed read-write-S4620 series-2.5 inch(3.5 inch bracket)-V7 dedicated-Solidigm | Current |
| 0255YEXF | SSD module-Servers-SSD-1920GB-SATA 6Gb/s-read-intensive-SE006 series-2.5 inch(3.5 inch bracket)-V7 dedicated | Current |
| 0255YEXM | SSD module-Servers-SSD-1920GB-SATA 6Gb/s-read-intensive-SE006 series-2.5 inch(2.5 inch bracket)-V7 dedicated | Current |
| 0255YEXQ | SSD module-Servers-SSD-1920GB-SATA 6Gb/s-read-intensive-PM893 series-2.5 inch(3.5 inch bracket)-V7 dedicated | Current |
| 0255YEXR | SSD module-Servers-SSD-3840GB-SATA 6Gb/s-read-intensive-SE006 series-2.5 inch(3.5 inch bracket)-V7 dedicated | Current |
| 0255YEXT | SSD module-Servers-SSD-1920GB-SATA 6Gb/s-read-intensive-PM893 series-2.5 inch(2.5 inch bracket)-V7 dedicated | Current |
| 0255YEXW | SSD module-Servers-SSD-3840GB-SATA 6Gb/s-read-intensive-SE006 series-2.5 inch(2.5 inch bracket)-V7 dedicated | Current |
| 0255YEYM | SSD module-Servers-SSD-480GB-SATA 6Gb/s-mixed read-write-S4620 series-2.5 inch(3.5 inch bracket)-V7 dedicated-Solidigm | Current |
| 0255YEYP | SSD module-Servers-SSD-960GB-SATA 6Gb/s-read-intensive-SE006 series-2.5 inch(3.5 inch bracket)-V7 dedicated | Current |
| 0255YEYQ | SSD module-Servers-SSD-480GB-SATA 6Gb/s-mixed read-write-S4620 series-2.5 inch(2.5 inch bracket)-V7 dedicated-Solidigm | Current |
| 0255YEYR | SSD module-Servers-SSD-1920GB-SATA 6Gb/s-mixed read-write-S4620 series-2.5 inch(3.5 inch bracket)-V7 dedicated-Solidigm | Current |
| 0255YEYT | SSD module-Servers-SSD-960GB-SATA 6Gb/s-read-intensive-SE006 series-2.5 inch(2.5 inch bracket)-V7 dedicated | Current |
| 0255YFAC | SSD module-Servers-SSD-1920GB-SATA 6Gb/s-mixed read-write-PM897 series-2.5 inch(3.5 inch bracket)-V7 dedicated | Current |
| 0255YFAF | SSD module-Servers-SSD-1920GB-SATA 6Gb/s-mixed read-write-PM897 series-2.5 inch(2.5 inch bracket)-V7 dedicated | Current |
| 0255YFAL | SSD module-Servers-SSD-1920GB-SATA 6Gb/s-read-intensive-S4520 series-2.5 inch(3.5 inch bracket)-V7 dedicated-Solidigm | Current |
| 0255YFAM | SSD module-Servers-SSD-1920GB-SATA 6Gb/s-read-intensive-S4520 series-2.5 inch(2.5 inch bracket)-V7 dedicated-Solidigm | Current |
| 0255YFAN | SSD module-Servers-SSD-3840GB-SATA 6Gb/s-read-intensive-S4520 series-2.5 inch(3.5 inch bracket)-V7 dedicated-Solidigm | Current |
| 0255YFAP | SSD module-Servers-SSD-3840GB-SATA 6Gb/s-read-intensive-S4520 series-2.5 inch(2.5 inch bracket)-V7 dedicated-Solidigm | Current |
| 0255YFBD | SSD module-Servers-SSD-960GB-SATA 6Gb/s-read-intensive-PM893 series-2.5 inch(2.5 inch bracket)-V7 dedicated | Current |
| 0255YFBE | SSD module-Servers-SSD-960GB-SATA 6Gb/s-read-intensive-PM893 series-2.5 inch(3.5 inch bracket)-V7 dedicated | Current |
| 0255YFBT | SSD module-Servers-SSD-960GB-SATA 6Gb/s-read-intensive-PM893 series-2.5 inch(3.5 inch bracket)-V7 dedicated-SED encrypted | Current |
| 0255YFCG | SSD module-Servers-SSD-480GB-SATA 6Gb/s-read-intensive-S4520 series-2.5 inch(3.5 inch bracket)-V7 dedicated-Solidigm | Current |
| 0255YFCH | SSD module-Servers-SSD-480GB-SATA 6Gb/s-read-intensive-S4520 series-2.5 inch(2.5 inch bracket)-V7 dedicated-Solidigm | Current |
| 0255YFCJ | SSD module-Servers-SSD-960GB-SATA 6Gb/s-read-intensive-S4520 series-2.5 inch(3.5 inch bracket)-V7 dedicated-Solidigm | Current |
| 0255YFCK | SSD module-Servers-SSD-960GB-SATA 6Gb/s-read-intensive-S4520 series-2.5 inch(2.5 inch bracket)-V7 dedicated-Solidigm | Current |
| 0254Y272 | generic drive module-Servers-generic drive-1200GB-SAS 12Gb/s-10000rpm-2.5inch-128MB and above-hot-swap-internal-2.5 inch bracket-V7 server dedicated | EOP |
| 0254Y398 | generic drive module-Servers-generic drive-12000GB-SATA 6.0Gb/s-7200rpm-3.5inch-256MB or above-hot-swap-internal-3.5 inch bracket-WD-V7 dedicated | EOM |
| 0254Y399 | generic drive module-Servers-generic drive-12000GB-SATA 6.0Gb/s-7200rpm-3.5inch-256MB or above-hot-swap-internal-3.5 inch bracket-Seagate-V7 dedicated | EOP |
| 0254Y443 | generic drive module-Servers-generic drive-16000GB-SATA 6.0Gb/s-7.2K rpm-3.5inch-hot-swap-internal-3.5 inch bracket-Toshiba-V7 dedicated | EOM |
| 0254Y445 | generic drive module-Servers-generic drive-16000GB-SATA 6.0Gb/s-7.2K rpm-3.5inch-256MB-hot-swap-internal-3.5 inch bracket-SEAGATE-V7 dedicated | EOM |
| 0254Y497 | generic drive module-Servers-generic drive-16000GB-SATA 6.0Gb/s-7.2K rpm-3.5inch-hot-swap-internal-3.5 inch bracket-WD-V7 dedicated | EOM |
| 0254Y498 | generic drive module-Servers-generic drive-20000GB-SATA 6.0Gb/s-7.2K rpm-256MB-3.5 inch-hot-swap-internal-3.5 inch bracket-WD-V7 dedicated | EOM |
| 0254Y499 | generic drive module-Servers-generic drive-20000GB-SATA 6.0Gb/s-7.2K rpm-256MB-3.5 inch-hot-swap-internal-3.5 inch bracket-Seagate-V7 dedicated | EOP |
| 0254Y603 | generic drive module-Servers-generic drive-8000GB-SATA 6Gb/s-7200rpm-3.5inch-128MB or above-hot-swap-internal-3.5 inch bracket-Toshiba-V7 dedicated | EOM |
| 0255Y397 | SSD module-Servers-SSD-240GB-SATA 6Gb/s-read-intensive-S4520 series-2.5 inch(2.5 inch bracket)-V7 dedicated | EOM |
| 0255Y398 | SSD module-Servers-SSD-240GB-SATA 6Gb/s-read-intensive-S4520 series-2.5 inch(3.5 inch bracket)-V7 dedicated | EOM |
| 0255Y399 | SSD module-Servers-SSD-480GB-SATA 6Gb/s-read-intensive-S4520 series-2.5 inch(2.5 inch bracket)-V7 dedicated | EOM |
| 0255Y400 | SSD module-Servers-SSD-480GB-SATA 6Gb/s-read-intensive-S4520 series-2.5 inch(3.5 inch bracket)-V7 dedicated | EOM |
| 0255Y401 | SSD module-Servers-SSD-960GB-SATA 6Gb/s-read-intensive-S4520 series-2.5 inch(2.5 inch bracket)-V7 dedicated | EOM |
| 0255Y402 | SSD module-Servers-SSD-960GB-SATA 6Gb/s-read-intensive-S4520 series-2.5 inch(3.5 inch bracket)-V7 dedicated | EOM |
| 0255Y403 | SSD module-Servers-SSD-1920GB-SATA 6Gb/s-read-intensive-S4520 series-2.5 inch(2.5 inch bracket)-V7 dedicated | EOM |
| 0255Y404 | SSD module-Servers-SSD-1920GB-SATA 6Gb/s-read-intensive-S4520 series-2.5 inch(3.5 inch bracket)-V7 dedicated | EOM |
| 0255Y405 | SSD module-Servers-SSD-3840GB-SATA 6Gb/s-read-intensive-S4520 series-2.5 inch(2.5 inch bracket)-V7 dedicated | EOM |
| 0255Y406 | SSD module-Servers-SSD-3840GB-SATA 6Gb/s-read-intensive-S4520 series-2.5 inch(3.5 inch bracket)-V7 dedicated | EOM |
| 0255Y407 | SSD module-Servers-SSD-480GB-SATA 6Gb/s-mixed read-write-S4620 series-2.5 inch(2.5 inch bracket)-V7 dedicated | EOM |
| 0255Y408 | SSD module-Servers-SSD-480GB-SATA 6Gb/s-mixed read-write-S4620 series-2.5 inch(3.5 inch bracket)-V7 dedicated | EOM |
| 0255Y409 | SSD module-Servers-SSD-960GB-SATA 6Gb/s-mixed read-write-S4620 series-2.5 inch(2.5 inch bracket)-V7 dedicated | EOM |
| 0255Y410 | SSD module-Servers-SSD-960GB-SATA 6Gb/s-mixed read-write-S4620 series-2.5 inch(3.5 inch bracket)-V7 dedicated | EOM |
| 0255Y411 | SSD module-Servers-SSD-1920GB-SATA 6Gb/s-mixed read-write-S4620 series-2.5 inch(2.5 inch bracket)-V7 dedicated | EOM |
| 0255Y412 | SSD module-Servers-SSD-1920GB-SATA 6Gb/s-mixed read-write-S4620 series-2.5 inch(3.5 inch bracket)-V7 dedicated | EOM |
| 0255Y413 | SSD module-Servers-SSD-3840GB-SATA 6Gb/s-mixed read-write-S4620 series-2.5 inch(2.5 inch bracket)-V7 dedicated | EOM |
| 0255Y414 | SSD module-Servers-SSD-3840GB-SATA 6Gb/s-mixed read-write-S4620 series-2.5 inch(3.5 inch bracket)-V7 dedicated | EOM |
| 0255Y415 | SSD module-Servers-SSD-240GB-SATA 6Gb/s-read-intensive-PM893 series-2.5 inch(2.5 inch bracket)-V7 dedicated | EOP |
| 0255Y416 | SSD module-Servers-SSD-240GB-SATA 6Gb/s-read-intensive-PM893 series-2.5 inch(3.5 inch bracket)-V7 dedicated | EOP |
| 0255Y442 | SSD module-Servers-SSD-240GB-SATA 6Gb/s-read-intensive-SE005 series-2.5 inch(2.5 inch bracket)-V7 dedicated | EOP |
| 0255Y443 | SSD module-Servers-SSD-240GB-SATA 6Gb/s-read-intensive-SE005 series-2.5 inch(3.5 inch bracket)-V7 dedicated | EOP |
| 0255Y444 | SSD module-Servers-SSD-480GB-SATA 6Gb/s-read-intensive-SE005 series-2.5 inch(2.5 inch bracket)-V7 dedicated | EOM |
| 0255Y445 | SSD module-Servers-SSD-480GB-SATA 6Gb/s-read-intensive-SE005 series-2.5 inch(3.5 inch bracket)-V7 dedicated | EOM |
| 0255Y446 | SSD module-Servers-SSD-960GB-SATA 6Gb/s-read-intensive-SE005 series-2.5 inch(2.5 inch bracket)-V7 dedicated | EOM |
| 0255Y447 | SSD module-Servers-SSD-960GB-SATA 6Gb/s-read-intensive-SE005 series-2.5 inch(3.5 inch bracket)-V7 dedicated | EOM |
| 0255Y448 | SSD module-Servers-SSD-1920GB-SATA 6Gb/s-read-intensive-SE005 series-2.5 inch(2.5 inch bracket)-V7 dedicated | EOM |
| 0255Y449 | SSD module-Servers-SSD-1920GB-SATA 6Gb/s-read-intensive-SE005 series-2.5 inch(3.5 inch bracket)-V7 dedicated | EOM |
| 0255Y450 | SSD module-Servers-SSD-240GB-SATA 6Gb/s-read-intensive-ES500 series-2.5 inch(2.5 inch bracket)-V7 dedicated | EOP |
| 0255Y451 | SSD module-Servers-SSD-240GB-SATA 6Gb/s-read-intensive-ES500 series-2.5 inch(3.5 inch bracket)-V7 dedicated | EOP |
| 0255Y452 | SSD module-Servers-SSD-480GB-SATA 6Gb/s-read-intensive-ES500 series-2.5 inch(2.5 inch bracket)-V7 dedicated | EOM |
| 0255Y453 | SSD module-Servers-SSD-480GB-SATA 6Gb/s-read-intensive-ES500 series-2.5 inch(3.5 inch bracket)-V7 dedicated | EOM |
| 0255Y454 | SSD module-Servers-SSD-960GB-SATA 6Gb/s-read-intensive-ES500 series-2.5 inch(2.5 inch bracket)-V7 dedicated | EOP |
| 0255Y455 | SSD module-Servers-SSD-960GB-SATA 6Gb/s-read-intensive-ES500 series-2.5 inch(3.5 inch bracket)-V7 dedicated | EOP |
| 0255Y456 | SSD module-Servers-SSD-1920GB-SATA 6Gb/s-read-intensive-ES500 series-2.5 inch(2.5 inch bracket)-V7 dedicated | EOM |
| 0255Y457 | SSD module-Servers-SSD-1920GB-SATA 6Gb/s-read-intensive-ES500 series-2.5 inch(3.5 inch bracket)-V7 dedicated | EOM |
| 0255Y887 | SSD module-Servers-SSD-240GB-SATA 6Gb/s-read-intensive-ES500 series-2.5 inch(2.5 inch bracket)-V7 dedicated-global | EOP |
| 0255Y888 | SSD module-Servers-SSD-240GB-SATA 6Gb/s-read-intensive-ES500 series-2.5 inch(3.5 inch bracket)-V7 dedicated-global | EOP |
| 0255Y889 | SSD module-Servers-SSD-480GB-SATA 6Gb/s-read-intensive-ES500 series-2.5 inch(2.5 inch bracket)-V7 dedicated-global | EOP |
| 0255Y890 | SSD module-Servers-SSD-480GB-SATA 6Gb/s-read-intensive-ES500 series-2.5 inch(3.5 inch bracket)-V7 dedicated-global | EOP |
| 0255Y891 | SSD module-Servers-SSD-960GB-SATA 6Gb/s-read-intensive-ES500 series-2.5 inch(2.5 inch bracket)-V7 dedicated-global | EOM |
| 0255Y892 | SSD module-Servers-SSD-960GB-SATA 6Gb/s-read-intensive-ES500 series-2.5 inch(3.5 inch bracket)-V7 dedicated-global | EOM |
| 0255Y893 | SSD module-Servers-SSD-1920GB-SATA 6Gb/s-read-intensive-ES500 series-2.5 inch(2.5 inch bracket)-V7 dedicated-global | EOM |
| 0255Y894 | SSD module-Servers-SSD-1920GB-SATA 6Gb/s-read-intensive-ES500 series-2.5 inch(3.5 inch bracket)-V7 dedicated-global | EOM |
| 0255Y998 | SSD module-Servers-SSD-960GB-SAS 12Gb/s-read-intensive-UM611a-Y series-2.5 inch(2.5 inch bracket)-shell optimized-V7 dedicated | EOM |
| 0255Y999 | SSD module-Servers-SSD-960GB-SAS 12Gb/s-read-intensive-UM611a-Y series-2.5 inch(3.5 inch bracket)-shell optimized-V7 dedicated | EOM |
| 0255YAAA | SSD module-Servers-SSD-1920GB-SAS 12Gb/s-read-intensive-UM611a-Y series-2.5 inch(2.5 inch bracket)-shell optimized-V7 dedicated | EOP |
| 0255YAAB | SSD module-Servers-SSD-1920GB-SAS 12Gb/s-read-intensive-UM611a-Y series-2.5 inch(3.5 inch bracket)-shell optimized-V7 dedicated | EOM |
| 0255YAAC | SSD module-Servers-SSD-3840GB-SAS 12Gb/s-read-intensive-UM611a-Y series-2.5 inch(2.5 inch bracket)-shell optimized-V7 dedicated | EOP |
| 0255YAAD | SSD module-Servers-SSD-3840GB-SAS 12Gb/s-read-intensive-UM611a-Y series-2.5 inch(3.5 inch bracket)-shell optimized-V7 dedicated | EOP |
| 0255YCDQ | SSD module-Servers-SSD-3200GB-SAS 12Gb/s-mixed read-write-UH631a-Y series-2.5 inch(2.5 inch bracket)-V7 dedicated | EOM |
| 0255YCDR | SSD module-Servers-SSD-3200GB-SAS 12Gb/s-mixed read-write-UH631a-Y series-2.5 inch(3.5 inch bracket)-V7 dedicated | EOM |
| 0255YCDS | SSD module-Servers-SSD-6400GB-SAS 12Gb/s-mixed read-write-UH631a-Y series-2.5 inch(2.5 inch bracket)-V7 dedicated | EOM |
| 0255YCDT | SSD module-Servers-SSD-6400GB-SAS 12Gb/s-mixed read-write-UH631a-Y series-2.5 inch(3.5 inch bracket)-V7 dedicated | EOM |
| 0255YCEE | SSD module-Servers-SSD-1920GB-SAS 12Gb/s-read-intensive-UH611a-Y series-2.5 inch(2.5 inch bracket)-V7 dedicated | EOM |
| 0255YCEG | SSD module-Servers-SSD-1920GB-SAS 12Gb/s-read-intensive-UH611a-Y series-2.5 inch(3.5 inch bracket)-V7 dedicated | EOM |
| 0255YCEH | SSD module-Servers-SSD-3840GB-SAS 12Gb/s-read-intensive-UH611a-Y series-2.5 inch(2.5 inch bracket)-V7 dedicated | EOM |
| 0255YCEJ | SSD module-Servers-SSD-3840GB-SAS 12Gb/s-read-intensive-UH611a-Y series-2.5 inch(3.5 inch bracket)-V7 dedicated | EOM |
| 0255YCEK | SSD module-Servers-SSD-7680GB-SAS 12Gb/s-read-intensive-UH611a-Y series-2.5 inch(2.5 inch bracket)-V7 dedicated | EOM |
| 0255YCEL | SSD module-Servers-SSD-7680GB-SAS 12Gb/s-read-intensive-UH611a-Y series-2.5 inch(3.5 inch bracket)-V7 dedicated | EOM |
| 0255Y434 | SSD Module,Servers,SSD,240GB,SATA 6Gb/s,Read Intensive,SSSTC-ER2-CD Series,2.5inch(2.5inch Drive Bay),V7 dedicated | Current Field replaceable |
| 0255Y435 | SSD Module,Servers,SSD,240GB,SATA 6Gb/s,Read Intensive,SSSTC-ER2-CD Series,2.5inch(3.5inch Drive Bay),V7 dedicated | Current Field replaceable |
| 0255Y425 | SSD Module,Servers,SSD,960GB,SATA 6Gb/s,Read Intensive,PM893V Series,2.5inch(2.5inch Drive Bay),V7 dedicated | Current Field replaceable |
| 0255Y305 | SSD Module,Servers,SSD,7680GB,NVMe PCIe,Read Intensive,PM9A3 Series,2.5inch(2.5inch Drive Bay),V7 dedicated | Current Field replaceable |
| 0255Y426 | SSD Module,Servers,SSD,960GB,SATA 6Gb/s,Read Intensive,PM893V Series,2.5inch(3.5inch Drive Bay),V7 dedicated | Current Field replaceable |
| 0254Y070 | Hard Disk Module,Servers,HDD,14TB,SATA 6.0Gb/s,7.2K rpm,3.5 inch,Hot_plug,Built-in,3.5 inch Drive Bay,V7 server dedicated | Current Field replaceable |
| 0255Y301 | SSD Module,Servers,SSD,1920GB,NVMe PCIe,Read Intensive,PM9A3 Series,2.5inch(2.5inch Drive Bay),V7 dedicated | Current Field replaceable |
| 0255Y303 | SSD Module,Servers,SSD,3840GB,NVMe PCIe,Read Intensive,PM9A3 Series,2.5inch(2.5inch Drive Bay),V7 dedicated | Current Field replaceable |
| 0254Y068 | Hard Disk Module,Servers,HDD,10TB,SATA 6.0Gb/s,7.2K rpm,3.5inch,256MB,Hot_plug,Built-in,3.5 inch Drive Bay,V7 server dedicated | Current Field replaceable |
| 0254Y066 | Hard Disk Module,Servers,HDD,6000GB,SATA 6.0Gb/s,7.2K rpm,3.5inch,128MB cache or above,Hot_plug,Built-in,3.5 inch Drive Bay,V7 server dedicated | Current Field replaceable |
| 0255Y440 | SSD Module,Servers,SSD,1920GB,SATA 6Gb/s,Read Intensive,SSSTC-ER2-CD Series,2.5inch(2.5inch Drive Bay),V7 dedicated | Current Field replaceable |
| 0255Y441 | SSD Module,Servers,SSD,1920GB,SATA 6Gb/s,Read Intensive,SSSTC-ER2-CD Series,2.5inch(3.5inch Drive Bay),V7 dedicated | Current Field replaceable |
| 0255Y436 | SSD Module,Servers,SSD,480GB,SATA 6Gb/s,Read Intensive,SSSTC-ER2-CD Series,2.5inch(2.5inch Drive Bay),V7 dedicated | Current Field replaceable |
| 0255Y437 | SSD Module,Servers,SSD,480GB,SATA 6Gb/s,Read Intensive,SSSTC-ER2-CD Series,2.5inch(3.5inch Drive Bay),V7 dedicated | Current Field replaceable |
| 0255Y438 | SSD Module,Servers,SSD,960GB,SATA 6Gb/s,Read Intensive,SSSTC-ER2-CD Series,2.5inch(2.5inch Drive Bay),V7 dedicated | Current Field replaceable |
| 0255Y439 | SSD Module,Servers,SSD,960GB,SATA 6Gb/s,Read Intensive,SSSTC-ER2-CD Series,2.5inch(3.5inch Drive Bay),V7 dedicated | Current Field replaceable |
| 0254Y305 | Hard Disk Module,Servers,HDD,8000GB,SATA 6.0Gb/s,7.2K rpm,3.5inch,128MB cache or above,Hot_plug,Built-in,3.5 inch Drive Bay,V7 server dedicated,Brand Customization Special | Current Field replaceable |
| 0255YAHP | SSD Module,Servers,SSD,3840GB,SATA 6Gb/s,Mixed Use,S4620 Series,2.5inch(3.5inch Drive Bay),V7 dedicated,Brand Customization Special | Current Field replaceable |
| 0255YAPG | SSD Module,Servers,SSD,480GB,SATA 6Gb/s,Read Intensive,PM893 Series,2.5inch(2.5inch Drive Bay),V7 dedicated,Brand Customization Special | Current Field replaceable |
| 0255YAHA | SSD Module,Servers,SSD,1920GB,SATA 6Gb/s,Read Intensive,S4520 Series,2.5inch(2.5inch Drive Bay),V7 dedicated,Brand Customization Special | Current Field replaceable |
| 0255YAQL | SSD Module,Servers,SSD,3840GB,SATA 6Gb/s,Mixed Use,PM897 Series,2.5inch(2.5inch Drive Bay),V7 dedicated,Brand Customization Special | Current Field replaceable |
| 0255Y627 | SSD Module,Servers,SSD,6400GB,NVMe PCIe,Mixed Use,UH831a,Y Series,2.5inch(3.5inch Drive Bay),V7 dedicated | Current Field replaceable |
| 0255Y902 | SSD Module,Servers,SSD,1600GB,NVMe PCIe,Mixed Use,EP600 Series,2.5inch(3.5inch Drive Bay),V7 dedicated,Global | Current Field replaceable |
| 0255Y904 | SSD Module,Servers,SSD,3200GB,NVMe PCIe,Mixed Use,EP600 Series,2.5inch(3.5inch Drive Bay),V7 dedicated,Global | Current Field replaceable |
| 0255Y469 | SSD Module,Servers,SSD,7680GB,NVMe PCIe,Read Intensive,P5520 Series,2.5inch(3.5inch Drive Bay),V7 dedicated | Current Field replaceable |
| 0255Y304 | SSD Module,Servers,SSD,3840GB,NVMe PCIe,Read Intensive,PM9A3 Series,2.5inch(3.5inch Drive Bay),V7 dedicated | Current Field replaceable |
| 0255Y623 | SSD Module,Servers,SSD,1600GB,NVMe PCIe,Mixed Use,UH831a,Y Series,2.5inch(3.5inch Drive Bay),V7 dedicated | Current Field replaceable |
| 0255Y306 | SSD Module,Servers,SSD,7680GB,NVMe PCIe,Read Intensive,PM9A3 Series,2.5inch(3.5inch Drive Bay),V7 dedicated | Current Field replaceable |
| 0255Y625 | SSD Module,Servers,SSD,3200GB,NVMe PCIe,Mixed Use,UH831a,Y Series,2.5inch(3.5inch Drive Bay),V7 dedicated | Current Field replaceable |
| 0255Y900 | SSD Module,Servers,SSD,7680GB,NVMe PCIe,Read Intensive,EP500 Series,2.5inch(3.5inch Drive Bay),V7 dedicated,Global | Current Field replaceable |
| 0255Y906 | SSD Module,Servers,SSD,6400GB,NVMe PCIe,Mixed Use,EP600 Series,2.5inch(3.5inch Drive Bay),V7 dedicated,Global | Current Field replaceable |
| 0255Y465 | SSD Module,Servers,SSD,1920GB,NVMe PCIe,Read Intensive,P5520 Series,2.5inch(3.5inch Drive Bay),V7 dedicated | Current Field replaceable |
| 0255Y300 | SSD Module,Servers,SSD,960GB,NVMe PCIe,Read Intensive,PM9A3 Series,2.5inch(3.5inch Drive Bay),V7 dedicated | Current Field replaceable |
| 0255Y467 | SSD Module,Servers,SSD,3840GB,NVMe PCIe,Read Intensive,P5520 Series,2.5inch(3.5inch Drive Bay),V7 dedicated | Current Field replaceable |
| 0255Y302 | SSD Module,Servers,SSD,1920GB,NVMe PCIe,Read Intensive,PM9A3 Series,2.5inch(3.5inch Drive Bay),V7 dedicated | Current Field replaceable |
| 0255Y898 | SSD Module,Servers,SSD,3840GB,NVMe PCIe,Read Intensive,EP500 Series,2.5inch(3.5inch Drive Bay),V7 dedicated,Global | Current Field replaceable |
| 0255YBAA | SSD Module,Servers,SSD,6400GB,NVMe PCIe,Mixed Use,PE321 Series,2.5inch(3.5inch Drive Bay),V7 dedicated | Current Field replaceable |
| 0255Y896 | SSD Module,Servers,SSD,1920GB,NVMe PCIe,Read Intensive,EP500 Series,2.5inch(3.5inch Drive Bay),V7 dedicated,Global | Current Field replaceable |
| 0255YAYX | SSD Module,Servers,SSD,3200GB,NVMe PCIe,Mixed Use,PE321 Series,2.5inch(3.5inch Drive Bay),V7 dedicated | Current Field replaceable |
| 0255YBVH | SSD Module,Servers,SSD,7680GB,NVMe PCIe,Read Intensive,SP520 Series,2.5inch(2.5inch Drive Bay),V7 dedicated | Current Field replaceable |
| 0255YBVG | SSD Module,Servers,SSD,3840GB,NVMe PCIe,Read Intensive,SP520 Series,2.5inch(3.5inch Drive Bay),V7 dedicated | Current Field replaceable |
| 0255YBVJ | SSD Module,Servers,SSD,7680GB,NVMe PCIe,Read Intensive,SP520 Series,2.5inch(3.5inch Drive Bay),V7 dedicated | Current Field replaceable |
| 0255YBVD | SSD Module,Servers,SSD,1920GB,NVMe PCIe,Read Intensive,SP520 Series,2.5inch(2.5inch Drive Bay),V7 dedicated | Current Field replaceable |
| 0255YBVF | SSD Module,Servers,SSD,3840GB,NVMe PCIe,Read Intensive,SP520 Series,2.5inch(2.5inch Drive Bay),V7 dedicated | Current Field replaceable |
| 0255YBVE | SSD Module,Servers,SSD,1920GB,NVMe PCIe,Read Intensive,SP520 Series,2.5inch(3.5inch Drive Bay),V7 dedicated | Current Field replaceable |
| 0255YBUN | SSD Module,Servers,SSD,6400GB,NVMe PCIe,Mixed Use,SP620 Series,2.5inch(2.5inch Drive Bay),V7 dedicated | Current Field replaceable |
| 0255YBUQ | SSD Module,Servers,SSD,3200GB,NVMe PCIe,Mixed Use,SP620 Series,2.5inch(2.5inch Drive Bay),V7 dedicated | Current Field replaceable |
| 0255YBUP | SSD Module,Servers,SSD,6400GB,NVMe PCIe,Mixed Use,SP620 Series,2.5inch(3.5inch Drive Bay),V7 dedicated | Current Field replaceable |
| 0255Y899 | SSD Module,Servers,SSD,7680GB,NVMe PCIe,Read Intensive,EP500 Series,2.5inch(2.5inch Drive Bay),V7 dedicated,Global | Current Field replaceable |
| 0255YBUS | SSD Module,Servers,SSD,1600GB,NVMe PCIe,Mixed Use,SP620 Series,2.5inch(2.5inch Drive Bay),V7 dedicated | Current Field replaceable |
| 0255YBUR | SSD Module,Servers,SSD,3200GB,NVMe PCIe,Mixed Use,SP620 Series,2.5inch(3.5inch Drive Bay),V7 dedicated | Current Field replaceable |
| 0255YBUT | SSD Module,Servers,SSD,1600GB,NVMe PCIe,Mixed Use,SP620 Series,2.5inch(3.5inch Drive Bay),V7 dedicated | Current Field replaceable |
| 0255Y299 | SSD Module,Servers,SSD,960GB,NVMe PCIe,Read Intensive,PM9A3 Series,2.5inch(2.5inch Drive Bay),V7 dedicated | Current Field replaceable |
| 0255Y470 | SSD Module,Servers,SSD,1600GB,NVMe PCIe,Mixed Use,EP600 Series,2.5inch(2.5inch Drive Bay),V7 dedicated | Current Field replaceable |
| 0255Y476 | SSD Module,Servers,SSD,1600GB,NVMe PCIe,Mixed Use,P5620 Series,2.5inch(2.5inch Drive Bay),V7 dedicated | Current Field replaceable |
| 0255Y477 | SSD Module,Servers,SSD,1600GB,NVMe PCIe,Mixed Use,P5620 Series,2.5inch(3.5inch Drive Bay),V7 dedicated | Current Field replaceable |
| 0255Y478 | SSD Module,Servers,SSD,3200GB,NVMe PCIe,Mixed Use,P5620 Series,2.5inch(2.5inch Drive Bay),V7 dedicated | Current Field replaceable |
| 0255Y479 | SSD Module,Servers,SSD,3200GB,NVMe PCIe,Mixed Use,P5620 Series,2.5inch(3.5inch Drive Bay),V7 dedicated | Current Field replaceable |
| 0255Y472 | SSD Module,Servers,SSD,3200GB,NVMe PCIe,Mixed Use,EP600 Series,2.5inch(2.5inch Drive Bay),V7 dedicated | Current Field replaceable |
| 0255Y474 | SSD Module,Servers,SSD,6400GB,NVMe PCIe,Mixed Use,EP600 Series,2.5inch(2.5inch Drive Bay),V7 dedicated | Current Field replaceable |
| 0255Y903 | SSD Module,Servers,SSD,3200GB,NVMe PCIe,Mixed Use,EP600 Series,2.5inch(2.5inch Drive Bay),V7 dedicated,Global | Current Field replaceable |
| 0255Y905 | SSD Module,Servers,SSD,6400GB,NVMe PCIe,Mixed Use,EP600 Series,2.5inch(2.5inch Drive Bay),V7 dedicated,Global | Current Field replaceable |
| 0255Y901 | SSD Module,Servers,SSD,1600GB,NVMe PCIe,Mixed Use,EP600 Series,2.5inch(2.5inch Drive Bay),V7 dedicated,Global | Current Field replaceable |
| 0255YBAR | SSD Module,Servers,SSD,3840GB,NVMe PCIe,Read Intensive,PE321 Series,2.5inch(3.5inch Drive Bay),V7 dedicated | Current Field replaceable |
| 0255Y466 | SSD Module,Servers,SSD,3840GB,NVMe PCIe,Read Intensive,P5520 Series,2.5inch(2.5inch Drive Bay),V7 dedicated | Current Field replaceable |
| 0255Y468 | SSD Module,Servers,SSD,7680GB,NVMe PCIe,Read Intensive,P5520 Series,2.5inch(2.5inch Drive Bay),V7 dedicated | Current Field replaceable |
| 0255Y341 | SSD Module,Servers,SSD,7680GB,NVMe PCIe,Read Intensive,EP500 Series,2.5inch(2.5inch Drive Bay),V7 dedicated | Current Field replaceable |
| 0255YBAQ | SSD Module,Servers,SSD,3840GB,NVMe PCIe,Read Intensive,PE321 Series,2.5inch(2.5inch Drive Bay),V7 dedicated | Current Field replaceable |
| 0255Y464 | SSD Module,Servers,SSD,1920GB,NVMe PCIe,Read Intensive,P5520 Series,2.5inch(2.5inch Drive Bay),V7 dedicated | Current Field replaceable |
| 0255Y337 | SSD Module,Servers,SSD,1920GB,NVMe PCIe,Read Intensive,EP500 Series,2.5inch(2.5inch Drive Bay),V7 dedicated | Current Field replaceable |
| 0255Y339 | SSD Module,Servers,SSD,3840GB,NVMe PCIe,Read Intensive,EP500 Series,2.5inch(2.5inch Drive Bay),V7 dedicated | Current Field replaceable |
| 0255Y895 | SSD Module,Servers,SSD,1920GB,NVMe PCIe,Read Intensive,EP500 Series,2.5inch(2.5inch Drive Bay),V7 dedicated,Global | Current Field replaceable |
| 0255Y897 | SSD Module,Servers,SSD,3840GB,NVMe PCIe,Read Intensive,EP500 Series,2.5inch(2.5inch Drive Bay),V7 dedicated,Global | Current Field replaceable |
| 0255Y480 | SSD Module,Servers,SSD,6400GB,NVMe PCIe,Mixed Use,P5620 Series,2.5inch(2.5inch Drive Bay),V7 dedicated | Current Field replaceable |
| 0255Y481 | SSD Module,Servers,SSD,6400GB,NVMe PCIe,Mixed Use,P5620 Series,2.5inch(3.5inch Drive Bay),V7 dedicated | Current Field replaceable |
| 0255YAYW | SSD Module,Servers,SSD,3200GB,NVMe PCIe,Mixed Use,PE321 Series,2.5inch(2.5inch Drive Bay),V7 dedicated | Current Field replaceable |
| 0255YAYY | SSD Module,Servers,SSD,6400GB,NVMe PCIe,Mixed Use,PE321 Series,2.5inch(2.5inch Drive Bay),V7 dedicated | Current Field replaceable |
| 0255YBFC | SSD Module,Servers,SSD,3200GB,NVMe PCIe,Mixed Use,UH831a,K Series,2.5inch(2.5inch Drive Bay),V7 dedicated | Current Field replaceable |
| 0255YBER | SSD Module,Servers,SSD,1600GB,NVMe PCIe,Mixed Use,UH831a,K Series,2.5inch(2.5inch Drive Bay),V7 dedicated | Current Field replaceable |
| 0255YASM | SSD Module,Servers,SSD,6400GB,NVMe PCIe,Mixed Use,R5300 Series,2.5inch(2.5inch Drive Bay),V7 dedicated | Current Field replaceable |
| 0255YASK | SSD Module,Servers,SSD,3200GB,NVMe PCIe,Mixed Use,R5301 Series,2.5inch(2.5inch Drive Bay),V7 dedicated | Current Field replaceable |
| 0255YASW | SSD Module,Servers,SSD,3840GB,NVMe PCIe,Read Intensive,J5100 Series,2.5inch(2.5inch Drive Bay),V7 dedicated | Current Field replaceable |
| 0255YBHS | SSD Module,Servers,SSD,3200GB,NVMe PCIe,Mixed Use,J5300 Series,2.5inch(2.5inch Drive Bay),V7 dedicated | Current Field replaceable |
| 0255YARX | SSD Module,Servers,SSD,3840GB,NVMe PCIe,Read Intensive,R5101 Series,2.5inch(2.5inch Drive Bay),V7 dedicated | Current Field replaceable |
| 0255YBGL | SSD Module,Servers,SSD,1600GB,NVMe PCIe,Mixed Use,J5300 Series,2.5inch(2.5inch Drive Bay),V7 dedicated | Current Field replaceable |
| 0255Y471 | SSD Module,Servers,SSD,1600GB,NVMe PCIe,Mixed Use,EP600 Series,2.5inch(3.5inch Drive Bay),V7 dedicated | Current Field replaceable |
| 0255Y473 | SSD Module,Servers,SSD,3200GB,NVMe PCIe,Mixed Use,EP600 Series,2.5inch(3.5inch Drive Bay),V7 dedicated | Current Field replaceable |
| 0255Y475 | SSD Module,Servers,SSD,6400GB,NVMe PCIe,Mixed Use,EP600 Series,2.5inch(3.5inch Drive Bay),V7 dedicated | Current Field replaceable |
| 0255YBAS | SSD Module,Servers,SSD,7680GB,NVMe PCIe,Read Intensive,PE321 Series,2.5inch(2.5inch Drive Bay),V7 dedicated | Current Field replaceable |
| 0255YAPB | SSD Module,Servers,SSD,7680GB,NVMe PCIe,Read Intensive,UH711a-Y Series,2.5inch(2.5inch Drive Bay),V7 Brand Customization Special | Current Field replaceable |
| 0255Y340 | SSD Module,Servers,SSD,3840GB,NVMe PCIe,Read Intensive,EP500 Series,2.5inch(3.5inch Drive Bay),V7 dedicated | Current Field replaceable |
| 0255Y342 | SSD Module,Servers,SSD,7680GB,NVMe PCIe,Read Intensive,EP500 Series,2.5inch(3.5inch Drive Bay),V7 dedicated | Current Field replaceable |
| 0255Y338 | SSD Module,Servers,SSD,1920GB,NVMe PCIe,Read Intensive,EP500 Series,2.5inch(3.5inch Drive Bay),V7 dedicated | Current Field replaceable |
| 0255YABK | SSD Module,Servers,SSD,7680GB,NVMe PCIe,Read intensive,R5100 Series,2.5inch(2.5inch Drive Bay),V7 dedicated | Current Field replaceable |
| 0255YASD | SSD Module,Servers,SSD,7680GB,NVMe PCIe,Read Intensive,J5100 Series,2.5inch(2.5inch Drive Bay),V7 dedicated | Current Field replaceable |
| 0255YBNW | SSD Module,Servers,SSD,6400GB,NVMe PCIe,Mixed Use,UH831a,K Series,2.5inch(2.5inch Drive Bay),V7 dedicated | Current Field replaceable |
| 0255YANW | SSD Module,Servers,SSD,3840GB,NVMe PCIe,Read Intensive,UH711a-Y Series,2.5inch(2.5inch Drive Bay),V7 Brand Customization Special | Current Field replaceable |
| 0255YANC | SSD Module,Servers,SSD,1920GB,NVMe PCIe,Read Intensive,PM9A3 Series,2.5inch(2.5inch Drive Bay),V7 Brand Customization Special | Current Field replaceable |
| 0255Y624 | SSD Module,Servers,SSD,3200GB,NVMe PCIe,Mixed Use,UH831a,Y Series,2.5inch(2.5inch Drive Bay),V7 dedicated | Current Field replaceable |
| 0255Y626 | SSD Module,Servers,SSD,6400GB,NVMe PCIe,Mixed Use,UH831a,Y Series,2.5inch(2.5inch Drive Bay),V7 dedicated | Current Field replaceable |
| 0255Y620 | SSD Module,Servers,SSD,7680GB,NVMe PCIe,Read Intensive,UH711a-Y Series,2.5inch(2.5inch Drive Bay),V7 dedicated | Current Field replaceable |
| 0255Y621 | SSD Module,Servers,SSD,7680GB,NVMe PCIe,Read Intensive,UH711a-Y Series,2.5inch(3.5inch Drive Bay),V7 dedicated | Current Field replaceable |
| 0255Y622 | SSD Module,Servers,SSD,1600GB,NVMe PCIe,Mixed Use,UH831a,Y Series,2.5inch(2.5inch Drive Bay),V7 dedicated | Current Field replaceable |
| 0255Y616 | SSD Module,Servers,SSD,1920GB,NVMe PCIe,Read Intensive,UH711a-Y Series,2.5inch(2.5inch Drive Bay),V7 dedicated | Current Field replaceable |
| 0255Y617 | SSD Module,Servers,SSD,1920GB,NVMe PCIe,Read Intensive,UH711a-Y Series,2.5inch(3.5inch Drive Bay),V7 dedicated | Current Field replaceable |
| 0255Y618 | SSD Module,Servers,SSD,3840GB,NVMe PCIe,Read Intensive,UH711a-Y Series,2.5inch(2.5inch Drive Bay),V7 dedicated | Current Field replaceable |
| 0255Y619 | SSD Module,Servers,SSD,3840GB,NVMe PCIe,Read Intensive,UH711a-Y Series,2.5inch(3.5inch Drive Bay),V7 dedicated | Current Field replaceable |
| 0255YBGM | SSD Module,Servers,SSD,1600GB,NVMe PCIe,Mixed Use,J5300 Series,2.5inch(3.5inch Drive Bay),V7 dedicated | Current Field replaceable |
| 0255YBFD | SSD Module,Servers,SSD,3200GB,NVMe PCIe,Mixed Use,UH831a,K Series,2.5inch(3.5inch Drive Bay),V7 dedicated | Current Field replaceable |
| 0255YBES | SSD Module,Servers,SSD,1600GB,NVMe PCIe,Mixed Use,UH831a,K Series,2.5inch(3.5inch Drive Bay),V7 dedicated | Current Field replaceable |
| 0255YAET | SSD Module,Servers,SSD,480GB,SATA 6Gb/s,Read Intensive,PM893 Series,2.5inch(2.5inch Drive Bay),V7 dedicated | Current Field replaceable |
| 0255YAEV | SSD Module,Servers,SSD,7680GB,NVMe PCIe,Read intensive,R5100 Series,2.5inch(2.5inch Drive Bay),V7 Appoint | Current Field replaceable |
| 0255YBAT | SSD Module,Servers,SSD,7680GB,NVMe PCIe,Read Intensive,PE321 Series,2.5inch(3.5inch Drive Bay),V7 dedicated | Current Field replaceable |
| 0255YBNX | SSD Module,Servers,SSD,6400GB,NVMe PCIe,Mixed Use,UH831a,K Series,2.5inch(3.5inch Drive Bay),V7 dedicated | Current Field replaceable |
| 0255Y857 | SSD Module,Servers,SSD,3200GB,NVMe PCIe,Mixed Use,UH831a,K Series,2.5inch(3.5inch Drive Bay),V7 dedicated | Current Field replaceable |
| 0254Y850 | Hard Disk Module,Servers,HDD,20000GB,SATA 6.0Gb/s,7.2K rpm,256MB,3.5inch,Hot-Swapping,Built-in,3.5inch Drive Bay,WDC-Paris CP,V7 dedicated | Current Field replaceable |
| 0255YAFM | SSD Module,Servers,SSD,7680GB,NVMe PCIe,Read Intensive,PM9A3 Series,2.5inch(2.5inch Drive Bay),V7 dedicated | Current Field replaceable |
| 0254Y810 | Hard Disk Module,Servers,HDD,24TB,SATA 6.0Gb/s,7.2K rpm,3.5inch,Hot-Swapping,Built-in,3.5inch Drive Bay,V7 dedicated | Current Field replaceable |
| 0254Y257 | Hard Disk Module,Servers,Hard Disk,12000GB,SATA 6Gb/s,7200rpm,3.5inch,256MB,Hot-swap,Built-in,3.5 inch Front Panel,V7 dedicated | Current Field replaceable |
| 0255YBQR | SSD Module,Servers,SSD,480GB,SATA 6Gb/s,Read Intensive,UNCIA3836 Series,2.5inch(2.5inch Drive Bay),V7 dedicated | Current Field replaceable |
| 0255YAKL | SSD Module,Servers,SSD,7680GB,NVMe PCIe,Read Intensive,CD8 Series,2.5inch(2.5inch Drive Bay),V7 dedicated | Current Field replaceable |
| 0255YDNX | SSD Module,Servers,SSD,7680GB,PCIE 5.0 X4,NVMe PCIe,Read Intensive,PF6050 Series,2.5inch(2.5inch Drive Bay),V7 dedicated | Current Field replaceable |
| 0254Y813 | Hard Disk Module,Servers,Hard Disk,24000GB,SATA 6.0Gb/s,7200rpm,3.5inch,Hot-Swapping,Built-in,3.5 inch Front Panel,Seagate,V7 dedicated | Current Field replaceable |
| 0255YEBL | SSD Module,Servers,SSD,7680GB,NVMe PCIe,Read Intensive,J6410 Series,2.5inch(2.5inch Drive Bay),V7 dedicated | Current Field replaceable |
| 0255YDPA | SSD Module,Servers,SSD,7680GB,NVMe PCIe 5.0 X4,Read Intensive,PF6050 Series,2.5inch(2.5inch Drive Bay),V7 dedicated | Current Field replaceable |
| 0255YBBD | SSD Module,Servers,SSD,6400GB,NVMe PCIe,Mixed Use,UH831a,K Series,2.5inch(2.5inch Drive Bay),V7 dedicated | Current Field replaceable |
| 0255YBBF | SSD Module,Servers,SSD,7680GB,NVMe PCIe,Read Intensive,UH811a-K Series,2.5inch(2.5inch Drive Bay),V7 dedicated | Current Field replaceable |
| 0255Y856 | SSD Module,Servers,SSD,3200GB,NVMe PCIe,Mixed Use,UH831a,K Series,2.5inch(2.5inch Drive Bay),V7 dedicated | Current Field replaceable |
| 0255YARV | SSD Module,Servers,SSD,7680GB,NVMe PCIe,Read Intensive,R5100 Series,2.5inch(3.5inch Drive Bay),V7 dedicated | Current Field replaceable |
| 0255YADX | SSD Module,Servers,SSD,3840GB,NVMe PCIe,Read Intensive,R5101 Series,2.5inch(3.5inch Drive Bay),V7 dedicated | Current Field replaceable |
| 0254Y351 | Hard Disk Module,Servers,HDD,8000GB,SATA 6.0Gb/s,7.2K rpm,3.5inch,128MB cache or above,Hot_plug,Built-in,3.5 inch Drive Bay,Toshiba,V7 dedicated | Current Field replaceable |
| 0254Y219 | Hard Disk Module,Servers,HDD,16000GB,SATA 6.0Gb/s,7.2K rpm,3.5inch,256MB cache,Hot_plug,Built-in,3.5 inch Drive Bay,SEAGATE,V7 dedicated | Current Field replaceable |
| 0255YASY | SSD Module,Servers,SSD,3840GB,NVMe PCIe,Read Intensive,J5100 Series,2.5inch(3.5inch Drive Bay),V7 dedicated | Current Field replaceable |
| 0255YASL | SSD Module,Servers,SSD,3200GB,NVMe PCIe,Mixed Use,R5301 Series,2.5inch(3.5inch Drive Bay),V7 dedicated | Current Field replaceable |
| 0254Y222 | Hard Disk Module,Servers,HDD,20000GB,SATA 6.0Gb/s,7.2K rpm,256MB,3.5inch,Hot-Swapping,Built-in,3.5inch Drive Bay,Seagate,V7 dedicated | Current Field replaceable |
| 0254Y221 | Hard Disk Module,Servers,HDD,16000GB,SATA 6.0Gb/s,7.2K rpm,3.5inch,Hot_plug,Built-in,3.5 inch Drive Bay,TOSHIBA,V7 dedicated | Current Field replaceable |
| 0255YENU | SSD Module,Servers,SSD,480GB,SATA 6Gb/s,Read intensive,PM893 Series,2.5inch(2.5inch Drive Bay),V7 dedicated | Current Field replaceable |
| 0255YENP | SSD Module,Servers,SSD,3840GB,NVMe PCIe,Read Intensive,P5520 Series,2.5inch(2.5inch Drive Bay),Solidigm,Formatting 4K | Current Field replaceable |
| 0255YENS | SSD Module,Servers,SSD,7680GB,PCIE 4.0 X4,Mixed Use,PM9A3 Series,2.5inch(2.5inch Drive Bay),formatted 4K,Customized drive,V7 dedicated | Current Field replaceable |
| 0255YENR | SSD Module,Servers,SSD,7680GB,PCIE 4.0 X4,Mixed Use,PM9A3 Series,2.5inch(2.5inch Drive Bay),7.68TB converted to 6.4TB & formatted 4K,NVMe SSD,7.68TB converted to 6.4TB & formatted 4K,Customized drive,V7 dedicated | Current Field replaceable |
| 0255YENG | SSD Module,Servers,SSD,480GB,SATA 6Gb/s,Read intensive,PM893 Series,2.5inch(3.5inch Drive Bay),V7 dedicated | Current Field replaceable |
| 0255YAFJ | SSD Module,Servers,SSD,960GB,NVMe PCIe,Read Intensive,PM9A3 Series,2.5inch(2.5inch Drive Bay),V7 dedicated | Current Field replaceable |
| 0255YAEX | SSD Module,Servers,SSD,7680GB,PCIE 4.0 X4,Read Intensive,PM9A3 Series,2.5inch(2.5inch Drive Bay),NVMe SSD,7.68TB converted to 6.4TB & formatted 4K,Customized drive,V7 dedicated | Current Field replaceable |
| 0255YAEW | SSD Module,Servers,SSD,7680GB,NVMe PCIe,Read Intensive,R5100 Series,2.5inch(3.5inch Drive Bay),V7 dedicated | Current Field replaceable |
| 0255YAEU | SSD Module,Servers,SSD,480GB,SATA 6Gb/s,Read Intensive,PM893 Series,2.5inch(3.5inch Drive Bay),V7 dedicated | Current Field replaceable |
| 0255YDVJ | SSD Module,SSD,3840GB,PCIE 5.0 X4,2.5inch Height 15mm,Read intensive,PF6050 Series,NVMe SSD,2.5inch(2.5inch Drive Bay),V7 dedicated | Current Field replaceable |
| 0255YABJ | SSD Module,Servers,SSD,6400GB,NVMe PCIe,Mixed Use,R5300 Series,2.5inch(2.5inch Drive Bay),Customer designated,V7 Appoint | Current Field replaceable |
| 0255YASA | SSD Module,Servers,SSD,6400GB,NVMe PCIe,Mixed Use,R5300 Series,2.5inch(3.5inch Drive Bay),V7 dedicated | Current Field replaceable |
| 0255YBTS | SSD Module,Servers,SSD,3200GB,NVMe PCIe,Mixed Use,J5300 Series,2.5inch(3.5inch Drive Bay),V7 dedicated | Current Field replaceable |
| 0255YBCT | SSD Module,Servers,SSD,3200GB,NVMe PCIe,Mixed Use,D6537 Series,2.5inch(3.5inch Drive Bay),V7 Dedicated | Current Field replaceable |
| 0255YBCS | SSD Module,Servers,SSD,3200GB,NVMe PCIe,Mixed Use,D6537 Series,2.5inch(2.5inch Drive Bay),V7 Dedicated | Current Field replaceable |
| 0255Y916 | SSD Module,Servers,SSD,3840GB,NVMe PCIe,Read Intensive,UH811a,Y Series,2.5inch(2.5inch Drive Bay),V7 | Current Field replaceable |
| 0255Y918 | SSD Module,Servers,SSD,7680GB,NVMe PCIe,Read Intensive,UH811a,Y Series,2.5inch(2.5inch Drive Bay),V7 | Current Field replaceable |
| 0255YAKE | SSD Module,Servers,SSD,960GB,SATA 6Gb/s,Read Intensive,PM893 Series,2.5inch(3.5inch Drive Bay),V7 dedicated | Current Field replaceable |
| 0255YAKH | SSD Module,Servers,SSD,1920GB,SATA 6Gb/s,Read Intensive,PM893 Series,2.5inch(3.5inch Drive Bay),V7 dedicated | Current Field replaceable |
| 0255YAKG | SSD Module,Servers,SSD,1920GB,SATA 6Gb/s,Read Intensive,PM893 Series,2.5inch(2.5inch Drive Bay),V7 dedicated | Current Field replaceable |
| 0255YAKB | SSD Module,Servers,SSD,7680GB,NVMe PCIe,Read Intensive,PM9A3 Series,2.5inch(2.5inch Drive Bay),V7 dedicated | Current Field replaceable |
| 0255YAKA | SSD Module,Servers,SSD,3840GB,PCIE 4.0 X4,Read Intensive,PM9A3 Series,2.5inch(3.5inch Drive Bay),NVMe SSD,V7 dedicated | Current Field replaceable |
| 0255YAKD | SSD Module,Servers,SSD,960GB,SATA 6Gb/s,Read Intensive,PM893 Series,2.5inch(2.5inch Drive Bay),V7 dedicated | Current Field replaceable |
| 0255YAKC | SSD Module,Servers,SSD,7680GB,PCIE 4.0 X4,Read Intensive,PM9A3 Series,2.5inch(3.5inch Drive Bay),NVMe SSD,V7 dedicated | Current Field replaceable |
| 0255YAKJ | SSD Module,Servers,SSD,3840GB,NVMe PCIe,Read Intensive,CD8 Series,2.5inch(2.5inch Drive Bay),V7 dedicated | Current Field replaceable |
| 0255YAKK | SSD Module,Servers,SSD,3840GB,PCIE 4.0 X4,Read Intensive,CD8 Series,2.5inch(3.5inch Drive Bay),NVMe SSD,V7 dedicated | Current Field replaceable |
| 0255YDNH | SSD Module,Servers,SSD,960GB,SATA 6Gb/s,Read intensive,ER3 Series,2.5inch(2.5inch Drive Bay),V7 dedicated | Current Field replaceable |
| 0255YDNP | SSD Module,Servers,SSD,15360GB,PCIE 5.0 X4,NVMe PCIe,Read Intensive,7940 Series,2.5inch(2.5inch Drive Bay),V7 dedicated | Current Field replaceable |
| 0255YDNJ | SSD Module,Servers,SSD,960GB,SATA 6Gb/s,Intensive,SSSTC ER3 CD Series,2.5inch(3.5inch Drive Bay),V7 dedicated | Current Field replaceable |
| 0255YAJY | SSD Module,Servers,SSD,3840GB,NVMe PCIe,Read Intensive,PM9A3 Series,2.5inch(2.5inch Drive Bay),V7 dedicated | Current Field replaceable |
| 0255YAJX | SSD Module,Servers,SSD,3840GB,NVMe PCIe,Read Intensive,PM9A3 Series,2.5inch(2.5inch Drive Bay),V7 dedicated,2TB customized from 3.84TB | Current Field replaceable |
| 0255YDPC | SSD Module,Servers,SSD,7680GB,NVMe PCIe,Read Intensive,PF6041G Series,2.5inch(3.5inch Drive Bay),V7 dedicated | Current Field replaceable |
| 0255YCMF | SSD Module,Servers,SSD,7680GB,NVMe PCIe,Read Intensive,J5100 Series,2.5inch(2.5inch Drive Bay),V7 dedicated | Current Field replaceable |
| P/N | Description / Specification | Status |
|---|---|---|
| 0255Y299 | SSD module-Servers-SSD-960GB-NVMe PCIe-read-intensive-PM9A3 series-2.5 inch(2.5 inch bracket)-V7 dedicated | Current |
| 0255Y300 | SSD module-Servers-SSD-960GB-NVMe PCIe-read-intensive-PM9A3 series-2.5 inch(3.5 inch bracket)-V7 dedicated | Current |
| 0255Y301 | SSD module-Servers-SSD-1920GB-NVMe PCIe-read-intensive-PM9A3 series-2.5 inch(2.5 inch bracket)-V7 dedicated | Current |
| 0255Y302 | SSD module-Servers-SSD-1920GB-NVMe PCIe-read-intensive-PM9A3 series-2.5 inch(3.5 inch bracket)-V7 dedicated | Current |
| 0255Y303 | SSD module-Servers-SSD-3840GB-NVMe PCIe-read-intensive-PM9A3 series-2.5 inch(2.5 inch bracket)-V7 dedicated | Current |
| 0255Y304 | SSD module-Servers-SSD-3840GB-NVMe PCIe-read-intensive-PM9A3 series-2.5 inch(3.5 inch bracket)-V7 dedicated | Current |
| 0255Y305 | SSD module-Servers-SSD-7680GB-NVMe PCIe-read-intensive-PM9A3 series-2.5 inch(2.5 inch bracket)-V7 dedicated | Current |
| 0255Y306 | SSD module-Servers-SSD-7680GB-NVMe PCIe-read-intensive-PM9A3 series-2.5 inch(3.5 inch bracket)-V7 dedicated | Current |
| 0255Y616 | SSD module-Servers-SSD-1920GB-NVMe PCIe-read-intensive-UH711a-Y series-2.5 inch(2.5 inch bracket)-V7 dedicated | Current |
| 0255Y617 | SSD module-Servers-SSD-1920GB-NVMe PCIe-read-intensive-UH711a-Y series-2.5 inch(3.5 inch bracket)-V7 dedicated | Current |
| 0255Y618 | SSD module-Servers-SSD-3840GB-NVMe PCIe-read-intensive-UH711a-Y series-2.5 inch(2.5 inch bracket)-V7 dedicated | Current |
| 0255Y619 | SSD module-Servers-SSD-3840GB-NVMe PCIe-read-intensive-UH711a-Y series-2.5 inch(3.5 inch bracket)-V7 dedicated | Current |
| 0255Y620 | SSD module-Servers-SSD-7680GB-NVMe PCIe-read-intensive-UH711a-Y series-2.5 inch(2.5 inch bracket)-V7 dedicated | Current |
| 0255Y621 | SSD module-Servers-SSD-7680GB-NVMe PCIe-read-intensive-UH711a-Y series-2.5 inch(3.5 inch bracket)-V7 dedicated | Current |
| 0255Y623 | SSD module-Servers-SSD-1600GB-NVMe PCIe-mixed read-write-UH831a series-Y series-2.5 inch(3.5 inch bracket)-V7 dedicated | Current |
| 0255Y896 | SSD module-Servers-SSD-1920GB-NVMe PCIe-read-intensive-EP500 series-2.5 inch(3.5 inch bracket)-V7 dedicated-global | Current |
| 0255Y897 | SSD module-Servers-SSD-3840GB-NVMe PCIe-read-intensive-EP500 series-2.5 inch(2.5 inch bracket)-V7 dedicated-global | Current |
| 0255Y898 | SSD module-Servers-SSD-3840GB-NVMe PCIe-read-intensive-EP500 series-2.5 inch(3.5 inch bracket)-V7 dedicated-global | Current |
| 0255Y902 | SSD module-Servers-SSD-1600GB-NVMe PCIe-mixed read-write-EP600 series-2.5 inch(3.5 inch bracket)-V7 dedicated-global | Current |
| 0255YABK | SSD module-Servers-SSD-7680GB-NVMe PCIe-read-intensive-R5100 series-2.5 inch(2.5 inch bracket)-V7 dedicated | Current |
| 0255YARV | SSD module-Servers-SSD-7680GB-NVMe PCIe-read-intensive-R5100 series-2.5 inch(3.5 inch bracket)-V7 dedicated | Current |
| 0255YARX | SSD module-Servers-SSD-3840GB-NVMe PCIe-read-intensive-R5101 series-2.5 inch(2.5 inch bracket)-V7 dedicated | Current |
| 0255YARY | SSD module-Servers-SSD-3840GB-NVMe PCIe-read-intensive-R5101 series-2.5 inch(3.5 inch bracket)-V7 dedicated | Current |
| 0255YASA | SSD module-Servers-SSD-6400GB-NVMe PCIe-mixed read-write-R5300 series-2.5 inch(3.5 inch bracket)-V7 dedicated | Current |
| 0255YASD | SSD module-Servers-SSD-7680GB-NVMe PCIe-read-intensive-J5100 series-2.5 inch(2.5 inch bracket)-V7 dedicated | Current |
| 0255YASK | SSD module-Servers-SSD-3200GB-NVMe PCIe-mixed read-write-R5301 series-2.5 inch(2.5 inch bracket)-V7 dedicated | Current |
| 0255YASL | SSD module-Servers-SSD-3200GB-NVMe PCIe-mixed read-write-R5301 series-2.5 inch(3.5 inch bracket)-V7 dedicated | Current |
| 0255YASM | SSD module-Servers-SSD-6400GB-NVMe PCIe-mixed read-write-R5300 series-2.5 inch(2.5 inch bracket)-V7 dedicated | Current |
| 0255YASW | SSD module-Servers-SSD-3840GB-NVMe PCIe-read-intensive-J5100 series-2.5 inch(2.5 inch bracket)-V7 dedicated | Current |
| 0255YASX | SSD module-Servers-SSD-7680GB-NVMe PCIe-read-intensive-J5100 series-2.5 inch(3.5 inch bracket)-V7 dedicated | Current |
| 0255YASY | SSD module-Servers-SSD-3840GB-NVMe PCIe-read-intensive-J5100 series-2.5 inch(3.5 inch bracket)-V7 dedicated | Current |
| 0255YAVD | SSD module-Servers-SSD-3200GB-NVMe PCIe-mixed read-write-UH831a-Y series-2.5 inch(2.5 inch bracket)-V7 dedicated-new platform | Current |
| 0255YAVE | SSD module-Servers-SSD-3200GB-NVMe PCIe-mixed read-write-UH831a-Y series-2.5 inch(3.5 inch bracket)-V7 dedicated-new platform | Current |
| 0255YAVF | SSD module-Servers-SSD-6400GB-NVMe PCIe-mixed read-write-UH831a-Y series-2.5 inch(2.5 inch bracket)-V7 dedicated-new platform | Current |
| 0255YAVG | SSD module-Servers-SSD-6400GB-NVMe PCIe-mixed read-write-UH831a-Y series-2.5 inch(3.5 inch bracket)-V7 dedicated-new platform | Current |
| 0255YAVH | SSD module-Servers-SSD-1600GB-NVMe PCIe-mixed read-write-UH831a-Y series-2.5 inch(2.5 inch bracket)-V7 dedicated-new platform | Current |
| 0255YAYU | SSD module-Servers-SSD-1600GB-NVMe PCIe-mixed read-write-PE321 series-2.5 inch(2.5 inch bracket)-V7 dedicated | Current |
| 0255YAYV | SSD module-Servers-SSD-1600GB-NVMe PCIe-mixed read-write-PE321 series-2.5 inch(3.5 inch bracket)-V7 dedicated | Current |
| 0255YAYW | SSD module-Servers-SSD-3200GB-NVMe PCIe-mixed read-write-PE321 series-2.5 inch(2.5 inch bracket)-V7 dedicated | Current |
| 0255YAYX | SSD module-Servers-SSD-3200GB-NVMe PCIe-mixed read-write-PE321 series-2.5 inch(3.5 inch bracket)-V7 dedicated | Current |
| 0255YAYY | SSD module-Servers-SSD-6400GB-NVMe PCIe-mixed read-write-PE321 series-2.5 inch(2.5 inch bracket)-V7 dedicated | Current |
| 0255YBAA | SSD module-Servers-SSD-6400GB-NVMe PCIe-mixed read-write-PE321 series-2.5 inch(3.5 inch bracket)-V7 dedicated | Current |
| 0255YBAN | SSD module-Servers-SSD-1920GB-NVMe PCIe-read-intensive-PE321 series-2.5 inch(2.5 inch bracket)-V7 dedicated | Current |
| 0255YBAP | SSD module-Servers-SSD-1920GB-NVMe PCIe-read-intensive-PE321 series-2.5 inch(3.5 inch bracket)-V7 dedicated | Current |
| 0255YBAQ | SSD module-Servers-SSD-3840GB-NVMe PCIe-read-intensive-PE321 series-2.5 inch(2.5 inch bracket)-V7 dedicated | Current |
| 0255YBAR | SSD module-Servers-SSD-3840GB-NVMe PCIe-read-intensive-PE321 series-2.5 inch(3.5 inch bracket)-V7 dedicated | Current |
| 0255YBAS | SSD module-Servers-SSD-7680GB-NVMe PCIe-read-intensive-PE321 series-2.5 inch(2.5 inch bracket)-V7 dedicated | Current |
| 0255YBAT | SSD module-Servers-SSD-7680GB-NVMe PCIe-read-intensive-PE321 series-2.5 inch(3.5 inch bracket)-V7 dedicated | Current |
| 0255YBER | SSD module-Servers-SSD-1600GB-NVMe PCIe-mixed read-write-UH831a series-K-2.5 inch(2.5 inch bracket)-V7 dedicated | Current |
| 0255YBES | SSD module-Servers-SSD-1600GB-NVMe PCIe-mixed read-write-UH831a-K series-2.5 inch(3.5 inch bracket)-V7 dedicated | Current |
| 0255YBFC | SSD module-Servers-SSD-3200GB-NVMe PCIe-mixed read-write-UH831a series-K-2.5 inch(2.5 inch bracket)-V7 dedicated | Current |
| 0255YBFD | SSD module-Servers-SSD-3200GB-NVMe PCIe-mixed read-write-UH831a-K series-2.5 inch(3.5 inch bracket)-V7 dedicated | Current |
| 0255YBGL | SSD module-Servers-SSD-1600GB-NVMe PCIe-mixed read-write-J5300 series-2.5 inch(2.5 inch bracket)-V7 dedicated | Current |
| 0255YBHS | SSD module-Servers-SSD-3200GB-NVMe PCIe-mixed read-write-J5300 series-2.5 inch(2.5 inch bracket)-V7 dedicated | Current |
| 0255YBNW | SSD module-Servers-SSD-6400GB-NVMe PCIe-mixed read-write-UH831a series-K-2.5 inch(2.5 inch bracket)-V7 dedicated | Current |
| 0255YBNX | SSD module-Servers-SSD-6400GB-NVMe PCIe-mixed read-write-UH831a-K series-2.5 inch(3.5 inch bracket)-V7 dedicated | Current |
| 0255YBTS | SSD module-Servers-SSD-3200GB-NVMe PCIe-mixed read-write-J5300 series-2.5 inch(3.5 inch bracket)-V7 dedicated | Current |
| 0255YBUN | SSD module-Servers-SSD-6400GB-NVMe PCIe-mixed read-write-SP620 series-2.5 inch(2.5 inch bracket)-V7 dedicated | Current |
| 0255YBUP | SSD module-Servers-SSD-6400GB-NVMe PCIe-mixed read-write-SP620 series-2.5 inch(3.5 inch bracket)-V7 dedicated | Current |
| 0255YBUQ | SSD module-Servers-SSD-3200GB-NVMe PCIe-mixed read-write-SP620 series-2.5 inch(2.5 inch bracket)-V7 dedicated | Current |
| 0255YBUR | SSD module-Servers-SSD-3200GB-NVMe PCIe-mixed read-write-SP620 series-2.5 inch(3.5 inch bracket)-V7 dedicated | Current |
| 0255YBUS | SSD module-Servers-SSD-1600GB-NVMe PCIe-mixed read-write-SP620 series-2.5 inch(2.5 inch bracket)-V7 dedicated | Current |
| 0255YBUT | SSD module-Servers-SSD-1600GB-NVMe PCIe-mixed read-write-SP620 series-2.5 inch(3.5 inch bracket)-V7 dedicated | Current |
| 0255YBVD | SSD module-Servers-SSD-1920GB-NVMe PCIe-read-intensive-SP520 series-2.5 inch(2.5 inch bracket)-V7 dedicated | Current |
| 0255YBVE | SSD module-Servers-SSD-1920GB-NVMe PCIe-read-intensive-SP520 series-2.5 inch(3.5 inch bracket)-V7 dedicated | Current |
| 0255YBVF | SSD module-Servers-SSD-3840GB-NVMe PCIe-read-intensive-SP520 series-2.5 inch(2.5 inch bracket)-V7 dedicated | Current |
| 0255YBVG | SSD module-Servers-SSD-3840GB-NVMe PCIe-read-intensive-SP520 series-2.5 inch(3.5 inch bracket)-V7 dedicated | Current |
| 0255YBVH | SSD module-Servers-SSD-7680GB-NVMe PCIe-read-intensive-SP520 series-2.5 inch(2.5 inch bracket)-V7 dedicated | Current |
| 0255YBVJ | SSD module-Servers-SSD-7680GB-NVMe PCIe-read-intensive-SP520 series-2.5 inch(3.5 inch bracket)-V7 dedicated | Current |
| 0255YCEV | SSD module-Servers-SSD-3840GB-NVMe PCIe-read-intensive-2.5 inch(2.5 inch bracket)-V7 dedicated-spec code | Current |
| 0255YCEV-001 | SSD module-Servers-SSD-3840GB-NVMe PCIe-read-intensive-P5520 series-2.5 inch(2.5 inch bracket)-V7 dedicated-Solidigm | Current |
| 0255YCEV-004 | SSD module-Servers-SSD-3840GB-NVMe PCIe-read-intensive-PM9A3 series-2.5 inch(2.5 inch bracket)-V7 dedicated-SAMSUNG-international edition | Current |
| 0255YCEW | SSD module-Servers-SSD-3840GB-NVMe PCIe-read-intensive-2.5 inch(3.5 inch bracket)-V7 dedicated-spec code | Current |
| 0255YCEW-001 | SSD module-Servers-SSD-3840GB-NVMe PCIe-read-intensive-P5520 series-2.5 inch(3.5 inch bracket)-V7 dedicated-Solidigm | Current |
| 0255YCEW-004 | SSD module-Servers-SSD-3840GB-NVMe PCIe-read-intensive-PM9A3 series-2.5 inch(3.5 inch bracket)-V7 dedicated-SAMSUNG-international edition | Current |
| 0255YCEX | SSD module-Servers-SSD-7680GB-NVMe PCIe-read-intensive-2.5 inch(2.5 inch bracket)-V7 dedicated-spec code | Current |
| 0255YCEX-002 | SSD module-Servers-SSD-7680GB-NVMe PCIe-read-intensive-P5520 series-2.5 inch(2.5 inch bracket)-V7 dedicated-Solidigm | Current |
| 0255YCEX-006 | SSD module-Servers-SSD-7680GB-NVMe PCIe-read-intensive-PM9A3 series-2.5 inch(2.5 inch bracket)-V7 dedicated-SAMSUNG-international edition | Current |
| 0255YCEY | SSD module-Servers-SSD-7680GB-NVMe PCIe-read-intensive-2.5 inch(3.5 inch bracket)-V7 dedicated-spec code | Current |
| 0255YCEY-001 | SSD module-Servers-SSD-7680GB-NVMe PCIe-read-intensive-P5520 series-2.5 inch(3.5 inch bracket)-V7 dedicated-Solidigm | Current |
| 0255YCEY-004 | SSD module-Servers-SSD-7680GB-NVMe PCIe-read-intensive-PM9A3 series-2.5 inch(3.5 inch bracket)-V7 dedicated-SAMSUNG-international edition | Current |
| 0255YCFA | SSD module-Servers-SSD-1600GB-NVMe PCIe-mixed read-write-2.5 inch(2.5 inch bracket)-V7 dedicated-spec code | Current |
| 0255YCFA-001 | SSD module-Servers-SSD-1600GB-NVMe PCIe-mixed read-write-P5620 series-2.5 inch(2.5 inch bracket)-V7 dedicated-Solidigm | Current |
| 0255YCFB | SSD module-Servers-SSD-1600GB-NVMe PCIe-mixed read-write-2.5 inch(3.5 inch bracket)-V7 dedicated-spec code | Current |
| 0255YCFB-001 | SSD module-Servers-SSD-1600GB-NVMe PCIe-mixed read-write-P5620 series-2.5 inch(3.5 inch bracket)-V7 dedicated-Solidigm | Current |
| 0255YCFC | SSD module-Servers-SSD-3200GB-NVMe PCIe-mixed read-write-2.5 inch(2.5 inch bracket)-V7 dedicated-spec code | Current |
| 0255YCFC-001 | SSD module-Servers-SSD-3200GB-NVMe PCIe-mixed read-write-P5620 series-2.5 inch(2.5 inch bracket)-V7 dedicated-Solidigm | Current |
| 0255YCFD | SSD module-Servers-SSD-3200GB-NVMe PCIe-mixed read-write-2.5 inch(3.5 inch bracket)-V7 dedicated-spec code | Current |
| 0255YCFD-001 | SSD module-Servers-SSD-3200GB-NVMe PCIe-mixed read-write-P5620 series-2.5 inch(3.5 inch bracket)-V7 dedicated-Solidigm | Current |
| 0255YCFE | SSD module-Servers-SSD-6400GB-NVMe PCIe-mixed read-write-2.5 inch(2.5 inch bracket)-V7 dedicated-spec code | Current |
| 0255YCFE-001 | SSD module-Servers-SSD-6400GB-NVMe PCIe-mixed read-write-P5620 series-2.5 inch(2.5 inch bracket)-V7 dedicated-Solidigm | Current |
| 0255YCFF | SSD module-Servers-SSD-6400GB-NVMe PCIe-mixed read-write-2.5 inch(3.5 inch bracket)-V7 dedicated-spec code | Current |
| 0255YCFF-001 | SSD module-Servers-SSD-6400GB-NVMe PCIe-mixed read-write-P5620 series-2.5 inch(3.5 inch bracket)-V7 dedicated-Solidigm | Current |
| 0255YCFQ | SSD module-Servers-SSD-1920GB-NVMe PCIe-read-intensive-2.5 inch(2.5 inch bracket)-V7 dedicated-spec code | Current |
| 0255YCFQ-001 | SSD module-Servers-SSD-1920GB-NVMe PCIe-read-intensive-P5520 series-2.5 inch(2.5 inch bracket)-V7 dedicated-Solidigm | Current |
| 0255YCFR | SSD module-Servers-SSD-1920GB-NVMe PCIe-read-intensive-2.5 inch(3.5 inch bracket)-V7 dedicated-spec code | Current |
| 0255YCFR-001 | SSD module-Servers-SSD-1920GB-NVMe PCIe-read-intensive-P5520 series-2.5 inch(3.5 inch bracket)-V7 dedicated-Solidigm | Current |
| 0255YEUA | SSD module-Servers-SSD-1920GB-NVMe PCIe-read-intensive-PE321 series-2.5 inch(3.5 inch bracket)-V7 dedicated | Current |
| 0255YEUB | SSD module-Servers-SSD-1920GB-NVMe PCIe-read-intensive-PE321 series-2.5 inch(2.5 inch bracket)-V7 dedicated | Current |
| 0255YEUX | SSD module-Servers-SSD-1920GB-NVMe PCIe-read-intensive-P5520 series-2.5 inch(2.5 inch bracket)-V7 dedicated-Solidigm | Current |
| 0255YEVB | SSD module-Servers-SSD-1920GB-NVMe PCIe-read-intensive-P5520 series-2.5 inch(3.5 inch bracket)-V7 dedicated-Solidigm | Current |
| 0255YEVH | SSD module-Servers-SSD-3200GB-NVMe PCIe-mixed read-write-PE321 series-2.5 inch(2.5 inch bracket)-V7 dedicated | Current |
| 0255YEVJ | SSD module-Servers-SSD-3200GB-NVMe PCIe-mixed read-write-PE321 series-2.5 inch(3.5 inch bracket)-V7 dedicated | Current |
| 0255YEWA | SSD module-Servers-SSD-3840GB-NVMe PCIe-read-intensive-PE321 series-2.5 inch(2.5 inch bracket)-V7 dedicated | Current |
| 0255YEWC | SSD module-Servers-SSD-3840GB-NVMe PCIe-read-intensive-PE321 series-2.5 inch(3.5 inch bracket)-V7 dedicated | Current |
| 0255YEWL | SSD module-Servers-SSD-1600GB-NVMe PCIe-mixed read-write-P5620 series-2.5 inch(2.5 inch bracket)-V7 dedicated-Solidigm | Current |
| 0255YEWN | SSD module-Servers-SSD-1600GB-NVMe PCIe-mixed read-write-P5620 series-2.5 inch(3.5 inch bracket)-V7 dedicated-Solidigm | Current |
| 0255YEWR | SSD module-Servers-SSD-7680GB-NVMe PCIe-read-intensive-PE321 series-2.5 inch(3.5 inch bracket)-V7 dedicated | Current |
| 0255YEWV | SSD module-Servers-SSD-1600GB-NVMe PCIe-mixed read-write-PE321 series-2.5 inch(2.5 inch bracket)-V7 dedicated | Current |
| 0255YEWW | SSD module-Servers-SSD-7680GB-NVMe PCIe-read-intensive-PE321 series-2.5 inch(2.5 inch bracket)-V7 dedicated | Current |
| 0255YEWX | SSD module-Servers-SSD-1600GB-NVMe PCIe-mixed read-write-PE321 series-2.5 inch(3.5 inch bracket)-V7 dedicated | Current |
| 0255YFAQ | SSD module-Servers-SSD-3200GB-NVMe PCIe-mixed read-write-UH831a-K series-2.5 inch(3.5 inch bracket)-V7 dedicated | Current |
| 0255YFAR | SSD module-Servers-SSD-3200GB-NVMe PCIe-mixed read-write-UH831a series-K-2.5 inch(2.5 inch bracket)-V7 dedicated | Current |
| 0255YFAW | SSD module-Servers-SSD-6400GB-NVMe PCIe-mixed read-write-PE321 series-2.5 inch(3.5 inch bracket)-V7 dedicated | Current |
| 0255YFAX | SSD module-Servers-SSD-6400GB-NVMe PCIe-mixed read-write-PE321 series-2.5 inch(2.5 inch bracket)-V7 dedicated | Current |
| 0255YFBV | SSD module-Servers-SSD-3840GB-NVMe PCIe-read-intensive-P5520 series-2.5 inch(3.5 inch bracket)-V7 dedicated-Solidigm | Current |
| 0255YFCA | SSD module-Servers-SSD-3840GB-NVMe PCIe-read-intensive-P5520 series-2.5 inch(2.5 inch bracket)-V7 dedicated-Solidigm | Current |
| 0255YFCB | SSD module-Servers-SSD-3200GB-NVMe PCIe-mixed read-write-P5620 series-2.5 inch(3.5 inch bracket)-V7 dedicated-Solidigm | Current |
| 0255YFCF | SSD module-Servers-SSD-3200GB-NVMe PCIe-mixed read-write-P5620 series-2.5 inch(2.5 inch bracket)-V7 dedicated-Solidigm | Current |
| 0255YFCV | SSD module-Servers-SSD-7680GB-NVMe PCIe-read-intensive-PM9A3 series-2.5 inch(3.5 inch bracket)-V7 dedicated | Current |
| 0255YFCY | SSD module-Servers-SSD-7680GB-NVMe PCIe-read-intensive-PM9A3 series-2.5 inch(2.5 inch bracket)-V7 dedicated | Current |
| 0255YFDK | SSD module-Servers-SSD-1920GB-NVMe PCIe-read-intensive-PM9A3 series-2.5 inch(2.5 inch bracket)-V7 dedicated | Current |
| 0255YFDN | SSD module-Servers-SSD-1920GB-NVMe PCIe-read-intensive-PM9A3 series-2.5 inch(3.5 inch bracket)-V7 dedicated | Current |
| 0255YFDV | SSD module-Servers-SSD-3840GB-NVMe PCIe-read-intensive-PM9A3 series-2.5 inch(2.5 inch bracket)-V7 dedicated | Current |
| 0255YFDW | SSD module-Servers-SSD-3840GB-NVMe PCIe-read-intensive-PM9A3 series-2.5 inch(3.5 inch bracket)-V7 dedicated | Current |
| 0255YFEG | SSD module-Servers-SSD-960GB-NVMe PCIe-read-intensive-PM9A3 series-2.5 inch(2.5 inch bracket)-V7 dedicated | Current |
| 0255YFEH | SSD module-Servers-SSD-960GB-NVMe PCIe-read-intensive-PM9A3 series-2.5 inch(3.5 inch bracket)-V7 dedicated | Current |
| 0255Y337 | SSD module-Servers-SSD-1920GB-NVMe PCIe-read-intensive-EP500 series-2.5 inch(2.5 inch bracket)-V7 dedicated | EOM |
| 0255Y338 | SSD module-Servers-SSD-1920GB-NVMe PCIe-read-intensive-EP500 series-2.5 inch(3.5 inch bracket)-V7 dedicated | EOM |
| 0255Y339 | SSD module-Servers-SSD-3840GB-NVMe PCIe-read-intensive-EP500 series-2.5 inch(2.5 inch bracket)-V7 dedicated | EOM |
| 0255Y340 | SSD module-Servers-SSD-3840GB-NVMe PCIe-read-intensive-EP500 series-2.5 inch(3.5 inch bracket)-V7 dedicated | EOM |
| 0255Y341 | SSD module-Servers-SSD-7680GB-NVMe PCIe-read-intensive-EP500 series-2.5 inch(2.5 inch bracket)-V7 dedicated | EOM |
| 0255Y342 | SSD module-Servers-SSD-7680GB-NVMe PCIe-read-intensive-EP500 series-2.5 inch(3.5 inch bracket)-V7 dedicated | EOM |
| 0255Y464 | SSD module-Servers-SSD-1920GB-NVMe PCIe-read-intensive-P5520 series-2.5 inch(2.5 inch bracket)-V7 dedicated | EOM |
| 0255Y465 | SSD module-Servers-SSD-1920GB-NVMe PCIe-read-intensive-P5520 series-2.5 inch(3.5 inch bracket)-V7 dedicated | EOM |
| 0255Y466 | SSD module-Servers-SSD-3840GB-NVMe PCIe-read-intensive-P5520 series-2.5 inch(2.5 inch bracket)-V7 dedicated | EOM |
| 0255Y467 | SSD module-Servers-SSD-3840GB-NVMe PCIe-read-intensive-P5520 series-2.5 inch(3.5 inch bracket)-V7 dedicated | EOM |
| 0255Y468 | SSD module-Servers-SSD-7680GB-NVMe PCIe-read-intensive-P5520 series-2.5 inch(2.5 inch bracket)-V7 dedicated | EOM |
| 0255Y469 | SSD module-Servers-SSD-7680GB-NVMe PCIe-read-intensive-P5520 series-2.5 inch(3.5 inch bracket)-V7 dedicated | EOM |
| 0255Y470 | SSD module-Servers-SSD-1600GB-NVMe PCIe-mixed read-write-EP600 series-2.5 inch(2.5 inch bracket)-V7 dedicated | EOM |
| 0255Y471 | SSD module-Servers-SSD-1600GB-NVMe PCIe-mixed read-write-EP600 series-2.5 inch(3.5 inch bracket)-V7 dedicated | EOP |
| 0255Y472 | SSD module-Servers-SSD-3200GB-NVMe PCIe-mixed read-write-EP600 series-2.5 inch(2.5 inch bracket)-V7 dedicated | EOM |
| 0255Y473 | SSD module-Servers-SSD-3200GB-NVMe PCIe-mixed read-write-EP600 series-2.5 inch(3.5 inch bracket)-V7 dedicated | EOM |
| 0255Y474 | SSD module-Servers-SSD-6400GB-NVMe PCIe-mixed read-write-EP600 series-2.5 inch(2.5 inch bracket)-V7 dedicated | EOP |
| 0255Y475 | SSD module-Servers-SSD-6400GB-NVMe PCIe-mixed read-write-EP600 series-2.5 inch(3.5 inch bracket)-V7 dedicated | EOP |
| 0255Y476 | SSD module-Servers-SSD-1600GB-NVMe PCIe-mixed read-write-P5620 series-2.5 inch(2.5 inch bracket)-V7 dedicated | EOM |
| 0255Y477 | SSD module-Servers-SSD-1600GB-NVMe PCIe-mixed read-write-P5620 series-2.5 inch(3.5 inch bracket)-V7 dedicated | EOM |
| 0255Y478 | SSD module-Servers-SSD-3200GB-NVMe PCIe-mixed read-write-P5620 series-2.5 inch(2.5 inch bracket)-V7 dedicated | EOM |
| 0255Y479 | SSD module-Servers-SSD-3200GB-NVMe PCIe-mixed read-write-P5620 series-2.5 inch(3.5 inch bracket)-V7 dedicated | EOM |
| 0255Y480 | SSD module-Servers-SSD-6400GB-NVMe PCIe-mixed read-write-P5620 series-2.5 inch(2.5 inch bracket)-V7 dedicated | EOM |
| 0255Y481 | SSD module-Servers-SSD-6400GB-NVMe PCIe-mixed read-write-P5620 series-2.5 inch(3.5 inch bracket)-V7 dedicated | EOM |
| 0255Y622 | SSD module-Servers-SSD-1600GB-NVMe PCIe-mixed read-write-UH831a series-Y-2.5 inch(2.5 inch bracket)-V7 dedicated | EOM |
| 0255Y624 | SSD module-Servers-SSD-3200GB-NVMe PCIe-mixed read-write-UH831a series-Y-2.5 inch(2.5 inch bracket)-V7 dedicated | EOM |
| 0255Y625 | SSD module-Servers-SSD-3200GB-NVMe PCIe-mixed read-write-UH831a series-Y series-2.5 inch(3.5 inch bracket)-V7 dedicated | EOM |
| 0255Y626 | SSD module-Servers-SSD-6400GB-NVMe PCIe-mixed read-write-UH831a series-Y-2.5 inch(2.5 inch bracket)-V7 dedicated | EOM |
| 0255Y627 | SSD module-Servers-SSD-6400GB-NVMe PCIe-mixed read-write-UH831a series-Y series-2.5 inch(3.5 inch bracket)-V7 dedicated | EOM |
| 0255Y895 | SSD module-Servers-SSD-1920GB-NVMe PCIe-read-intensive-EP500 series-2.5 inch(2.5 inch bracket)-V7 dedicated-global | EOM |
| 0255Y899 | SSD module-Servers-SSD-7680GB-NVMe PCIe-read-intensive-EP500 series-2.5 inch(2.5 inch bracket)-V7 dedicated-global | EOM |
| 0255Y900 | SSD module-Servers-SSD-7680GB-NVMe PCIe-read-intensive-EP500 series-2.5 inch(3.5 inch bracket)-V7 dedicated-global | EOM |
| 0255Y901 | SSD module-Servers-SSD-1600GB-NVMe PCIe-mixed read-write-EP600 series-2.5 inch(2.5 inch bracket)-V7 dedicated-global | EOM |
| 0255Y903 | SSD module-Servers-SSD-3200GB-NVMe PCIe-mixed read-write-EP600 series-2.5 inch(2.5 inch bracket)-V7 dedicated-global | EOM |
| 0255Y904 | SSD module-Servers-SSD-3200GB-NVMe PCIe-mixed read-write-EP600 series-2.5 inch(3.5 inch bracket)-V7 dedicated-global | EOM |
| 0255Y905 | SSD module-Servers-SSD-6400GB-NVMe PCIe-mixed read-write-EP600 series-2.5 inch(2.5 inch bracket)-V7 dedicated-global | EOM |
| 0255Y906 | SSD module-Servers-SSD-6400GB-NVMe PCIe-mixed read-write-EP600 series-2.5 inch(3.5 inch bracket)-V7 dedicated-global | EOM |
| 0255YAVJ | SSD module-Servers-SSD-1600GB-NVMe PCIe-mixed read-write-UH831a-Y series-2.5 inch(3.5 inch bracket)-V7 dedicated-new platform | EOM |
| 0255YBGM | SSD module-Servers-SSD-1600GB-NVMe PCIe-mixed read-write-J5300 series-2.5 inch(3.5 inch bracket)-V7 dedicated | EOM |
| 0255Y696 | SSD Module,Servers,M.2 SSD,SATA 6Gb/s-240GB,80.0mm * 22.0mm * 3.58 mm(Non-hot-swappable),ER3 series | Current Field replaceable |
| 0255Y698 | SSD Module,Servers,M.2 SSD,SATA 6Gb/s-480GB,80.0mm * 22.0mm * 3.58 mm(Non-hot-swappable),ER3 series | Current Field replaceable |
| 0255YCUL | SSD Module,Servers,M.2 SSD,NVMe PCIe,960GB,80.0mm * 22.0mm * 3.58 mm(Non-hot-swappable),PJ1 series | Current Field replaceable |
| 0255Y697 | SSD Module,Servers,M.2 SSD,SATA 6Gb/s-480GB,80.0mm * 22.0mm * 3.58 mm(hot-swappable),ER3 series | Current Field replaceable |
| 0255YGFS | SSD Module,Servers,M.2 SSD,NVMe PCIe,960GB,80.0mm * 22.0mm * 3.58 mm,PJ1 series | Current Field replaceable |
| 0255Y695 | SSD Module,Servers,M.2 SSD,SATA 6Gb/s-240GB,80.0mm * 22.0mm * 3.58 mm(hot-swappable),ER3 series | Current Field replaceable |
| 0255YDPD | SSD Module,Servers,PM893,M.2 SSD,SATA 6Gb/s-480GB,80.0mm * 22.0mm * 3.58 mm(not hot-swappable),V7 dedicated | Current Field replaceable |
| 0255YDBG | SSD Module,Servers,M.2 SSD,SATA,480GB,80.0mm * 22.0mm * 3.58 mm(no hot-swappable),ER3 series | Current Field replaceable |
| 0255YDXH | SSD Module,Servers,M.2 SSD,SATA 6Gb/s-480GB,80.0mm * 22.0mm * 3.58 mm(Non-hot-swappable),ER3 series | Current Field replaceable |
| P/N | Description / Specification | Status |
|---|---|---|
| 02312FLQ | function module-2288H V5-BC1SPSCA11-INTEL VROC KEY,advanced edition,supports RAID 0/1/10/5 | Current |
| 02312FLR | function module-2288H V5-BC1SPSCA12-INTEL VROC KEY,standard edition,supports RAID 0/1/10 | Current |
| 02312QWW | function module-9460-8i 4G-CN2M94608I4G-9460-8i 4G other board card-12G SAS RAID card-4G cache-8*12Gb/s SAS PHY-2 miniSAS HD internal interface-PCIE 3.1 X8-Vendor ID 1000-Device ID 0016-1-Subvendor ID 1000-Subdevice ID 9461 | Current |
| 02312QWY | function module-9440-8i 0G-CN2M94408I0G-9440-8i 0G other board card-12G SAS RAID card-no cache-8*12Gb/s SAS PHY-2 miniSAS HD internal interface-PCIE 3.1 X8-Vendor ID 1000-Device ID 0017-1-Subvendor ID 1000-Subdevice ID 9440 | Current |
| 02312SJG | function module-9460-16i 4G-CN2M946016I4G-9460-16i 4G other board card-12G SAS RAID card-4G cache-16*12Gb/s SAS PHY-4 miniSAS HD internal interface-PCIE 3.1 X8-Vendor ID 1000-Device ID 0014-1-Subvendor ID 1000-Subdevice ID 9460 | Current |
| 0231Y131 | function module-9560-16i 8G-CN2M956016I8G-9560-16i 8G other board card-12G SAS RAID card-8G cache-16*12Gb/s SAS PHY-2 slimline internal interface-PCIE 4.0 X8-Vendor ID 1000-Device ID 10E2-Subvendor ID 1000-Subdevice ID 4000 | Current |
| 0231Y338 | function module-Public Module-CN2M05RLCAC-XP460C-M 4G SAS/SATA/NVMe RAID card standardcard,RAID0,1,5,6,10,50,60,4GB Cache(Avago3516),supports supercap & sideband management-full-height half-length-PCIE 3.0 X8-Vendor ID 1000-Device ID 0014 | Current |
| 0231Y735 | function module-9540-8i-CN2M95408I-PCIE 4.0 X8-Vendor ID 1000-Device ID 10E6-1-Subvendor ID 1000-Subdevice ID 40D5-12G SAS RAID-9540-8i-x8 PCIe 4.0-9540-8i SAS RAID Card,SAS3808,No CacheVault,12Gb/s SAS,6Gb/s SATA,PCIe(NVMe)-9540-8i | Current |
| 0231Y736 | function module-9540-16i-CN2M954016I-PCIE 4.0 X8-Vendor ID 1000-Device ID 10E6-1-Subvendor ID 1000-Subdevice ID 40D0-12G SAS RAID-x8 PCIe 4.0-9540-16i SAS RAID Card,SAS3816,No CacheVault,12Gb/s SAS,6Gb/s SATA,PCIe(NVMe)-9540-16i | Current |
| 0231YBWV | function module-Public Module-BC5M01RLAD-XC470C-M-8i 4G-(SAS3908)-RAID cable card-RAID0,1,5,6,10,50,60-12Gb/s-4GB Cache-supports supercap & sideband management-PCIE 4.0 X8-Vendor ID 1000-Device ID 10E2-1-Subvendor ID 1F24-Subdevice ID 3000 | Current |
| 0231YBWX | function module-Public Module-BC5M01RLADB-XC470C-M-16i 4G-(SAS3916)-RAID cable card-RAID0,1,5,6,10,50,60-12Gb/s-4GB Cache-supports supercap & sideband management-PCIE 4.0 X8-Vendor ID 1000-Device ID 10E2-1-Subvendor ID 1F24-Subdevice ID 3001 | Current |
| 0231YBWY | function module-Public Module-BC5M01RLAE-XC170-M-8i-(SAS3808iMR)-SAS/SATA RAID cable card-RAID0,1,10-12Gb/s-no Cache-supports sideband management-PCIE 4.0 X8-Vendor ID 1000-Device ID 10E6-1-Subvendor ID 1F24-Subdevice ID 3002 | Current |
| 0231YBXA | function module-Public Module-BC5M01RLAEA-XC170-M-16i-(SAS3816iMR)-SAS/SATA RAID cable card-RAID0,1,10-12Gb/s-no Cache-supports sideband management-PCIE 4.0 X8-Vendor ID 1000-Device ID 10E6-1-Subvendor ID 1F24-Subdevice ID 3005 | Current |
| 0231YBXC | function module-Public Module-BC5M01RLAEC-XC370-M-16i-(SAS3816IT)-SAS/SATA RAID cable card-None RAID-12Gb/s-no Cache-supports sideband management-PCIE 4.0 X8-Vendor ID 1000-Device ID 00E6-1-Subvendor ID 1F24-Subdevice ID 3007 | Current |
| 0256Y050 | RAID card module-9560-8i 4G-CN2M95608I4G-9560-8i 4G other board card-12G SAS RAID card-4G cache-8*12Gb/s SAS PHY-1 slimline internal interface | Current |
| 0256Y064 | RAID card module-Public Module-BC5M01RLAH1-XP270-M2-(SAS3808-BootCard)-M.2 RAID standardcard-RAID0,1,JBOD-No Cache-supports sideband management-half-height half-length-full-height bracket-PCIe 4.0 x8 | Current |
| 0256Y066 | RAID card module-Public Module-BC5M02RLAH1-XP270-M2-(SAS3808-BootCard)-M.2 RAID standardcard-RAID0,1,JBOD-No Cache-supports sideband management-half-height half-length-half-height bracket-PCIe 4.0 x8 | Current |
| 0256Y106 | RAID card module-2288H V7-Dapustor F6100-PCIE 4.0 X4-Vendor ID 1e3b-Device ID 50b1-1-Subvendor ID 1e3b-Subdevice ID 50b1-PCIE 4.0 X4-Dapustor F6100 RAID Card-DP808AL-6Gb/s SATA,PCIE5.0 X2 NVMe-Chinese documentation | Current |
| 0256Y146 | RAID card module-Public Module-CN2M95808I8E-PCIe 4.0 x8-9580-8i8e SAS RAID Card,SAS3916,8G CacheVault,CVPM05-12Gb/s SAS,6Gb/s SATA,PCIe(NVMe)-included 1pcs low-profile bracket-for use with matching drive backplane | Current |
| 0256Y174 | RAID card module-2288H V7-9560-8i 4G-12G SAS RAID card-9560-8i-(SAS3908)-CVPM05-12Gb/s SAS-6Gb/s SATA-PCIe(NVMe)-4G CacheVault-PCIE 4.0 X8-Vendor ID 1000-Device ID 10E2-Subvendor ID 1000-Subdevice ID 4010 | Current |
| 0256Y179 | RAID card module-2288H V7-9560-16i 8G-12G SAS RAID card-9560-16i-(SAS3916)-CVPM05-12Gb/s SAS,6Gb/s SATA,PCIe(NVMe)-8G CacheVault-PCIE 4.0 X8-Vendor ID 1000-Device ID 10E2-Subvendor ID 1000-Subdevice ID 4000 | Current |
| NA | INTEL VROC SATA RAID 0/1/10/5 | Current |
| 02312QWV | function module-9460-8i 2G-CN2M94608I2G-9460-8i 2G other board card-12G SAS RAID card-2G cache-8*12Gb/s SAS PHY-2 miniSAS HD internal interface-PCIE 3.1 X8-Vendor ID 1000-Device ID 0016-1-Subvendor ID 1000-Subdevice ID 9461 | EOM |
| 0231Y129 | function module-9560-8i 4G-CN2M95608I4G-9560-8i 4G other board card-12G SAS RAID card-4G cache-8*12Gb/s SAS PHY-1 slimline internal interface-PCIE 4.0 X8-Vendor ID 1000-Device ID 10E2-Subvendor ID 1000-Subdevice ID 4010 | EOM |
| 0231YBXB | function module-Public Module-BC5M01RLAEB-XC370-M-8i-(SAS3808IT)-SAS/SATA RAID cable card-None RAID-12Gb/s-no Cache-supports sideband management-PCIE 4.0 X8-Vendor ID 1000-Device ID 00E6-1-Subvendor ID 1F24-Subdevice ID 3006 | EOP |
| 0817Y002 | Super capacitor module,64mm*51mm*13.1mm,Wire mounting,split from 08170002,NA,7600uF,5h | Current Field replaceable |
| 0302Y201 | Manufactured Board-JDM,Public Module,BC55RLAD,XC470C-M-8i 4G-(SAS3908)-RAID Cable Card-RAID0,1,5,6,10,50,60-12Gb/s-4GB Cache,Capacitor and Management,PCIE 4.0 X8-Vendor ID 1000-Device ID 10E2-1-Subvendor ID 1F24-Subdevice ID 3000,1*1 | Current Field replaceable |
| 0302Y204 | Manufactured Board-JDM,Public Module,BC56RLAE,XC170-M-8i-(SAS3808iMR)-SAS/SATA RAID Cable Card-RAID0,1,10-12Gb/s-no Cache,Support Sideband Management,PCIE 4.0 X8-Vendor ID 1000-Device ID 10E6-1-Subvendor ID 1F24-Subdevice ID 3002,1*1 | Current Field replaceable |
| 0256Y031 | RAID Card Module,Public Module,BC5M01RLAH,XP270-M-(SAS3808-BootCard)-M.2 RAID PCIE card-RAID0,1,JBOD-No CacheSupport Sideband Management,Half-height Half-length,Full Handle bars,PCIe 4.0 x8 | Current Field replaceable |
| 0256Y032 | RAID Card Module,Public Module,BC5M02RLAH,XP270-M-(SAS3808-BootCard)-M.2 RAID PCIE card-RAID0,1,JBOD-No CacheSupport Sideband Management,Half-height Half-length,Half Handle bars,PCIe 4.0 x8 | Current Field replaceable |
| 0256Y025 | RAID Card Module,2288H V6,9500-8e,PCIE 4.0 X8-Vendor ID 1000-Device ID 00E6-1-Subvendor ID 1000-Subdevice ID 4080-12G SAS RAID-x8 PCIe 4.0-9500-8e SAS RAID Card,SAS3808,No CacheVault,12Gb/s SAS,6Gb/s SATA,PCIe(NVMe)-9500-8e | Current Field replaceable |
| 0302Y203 | Manufactured Board-JDM,Public Module,BC55RLADB,XC470C-M-16i 4G-(SAS3916)-RAID Cable Card-RAID0,1,5,6,10,50,60-12Gb/s-4GB Cache, Capacitor and Management,PCIE 4.0 X8-Vendor ID 1000-Device ID 10E2-1-Subvendor ID 1F24-Subdevice ID 3001,1*1 | Current Field replaceable |
| 0231Y752 | Function Module,9580-8i8e,CN2M95808I8E,PCIe 4.0 x8-9580-8i8e SAS RAID Card,SAS3916, 8G CacheVault,CVPM05-12Gb/s SAS,6Gb/s SATA,PCIe(NVMe)-9580-8i8e,Comes with 1pcs short flap | Current Field replaceable |
| 0302Y205 | Manufactured Board-JDM,Public Module,BC56RLAEA,XC170-M-16i-(SAS3816iMR)-SAS/SATA RAID Cable Card-RAID0,1,10-12Gb/s-no Cache,Support Sideband Management,PCIE 4.0 X8-Vendor ID 1000-Device ID 10E6-1-Subvendor ID 1F24-Subdevice ID 3005,1*1 | Current Field replaceable |
| 0302Y207 | Manufactured Board-JDM,Public Module,BC56RLAEC,XC370-M-16i-(SAS3816IT)-SAS/SATA RAID Cable Card-None RAID-12Gb/s-no Cache,Support Sideband Management,PCIE 4.0 X8-Vendor ID 1000-Device ID 00E6-1-Subvendor ID 1F24-Subdevice ID 3007,1*1 | Current Field replaceable |
| P/N | Description / Specification | Status |
|---|---|---|
| 0231Y238 | function module-Public Module-BC51M03ETHK1-XP382 Ethernet adapter-25GE optical port(Mellanox CX5)-dual-port-SFP28(optical module not included)-half-height half-length-full-height bracket-PCIe 3.0 x8 | Current |
| 0231Y752 | function module-9580-8i8e-CN2M95808I8E-PCIe 4.0 x8-9580-8i8e SAS RAID Card,SAS3916,8G CacheVault,CVPM05-12Gb/s SAS,6Gb/s SATA,PCIe(NVMe)-9580-8i8e-included 1pcs low-profile bracket | Current |
| 0231Y803 | function module-Servers-CN2M01ITGBA1-XP210 Intel I350 2*GE+half-height half-length(incl. half-height & full-height brackets)standard network adapter-PCIE 2.0 X4-Vendor ID 8086-Device ID 1521-2 | Current |
| 0231Y804 | function module-Servers-CN2M01ITGC1-XP212 Intel I350 4*GE+half-height half-length(incl. half-height & full-height brackets)standard network adapter-PCIE 2.0 X4-Vendor ID 8086-Device ID 1521-4 | Current |
| 0231Y809 | function module-Servers-CN2M04ITGG1-XP330 Ethernet adapter-10Gb optical port(Intel X710)-dual-port-SFP+(optical module not included)-half-height half-length(incl. half-height & full-height brackets)-PCIe 3.0 x8 | Current |
| 0231Y812 | function module-Servers-CN2M03ITGH1-XP332 Ethernet adapter-10Gb optical port(Intel XL710)-quad-port-SFP+(optical module not included)-half-height half-length(incl. half-height & full-height brackets)-PCIe 3.0 x8 | Current |
| 0231Y821 | function module-Servers-BC5M01ETHK1-XP382 Ethernet adapter-25GE optical port(Mellanox CX5)-dual-port-SFP28(optical module not included)-half-height half-length(incl. half-height & full-height brackets)-PCIe 3.0 x8 | Current |
| 0231Y826 | function module-Servers-BC5M06ETHK1-XP382 Ethernet adapter-25GE optical port(Mellanox CX5)-dual-port-SFP28(incl. 2 optical modules)-half-height half-length-full-height bracket-PCIe 3.0 x8(domestic & overseas) | Current |
| 0231Y829 | function module-Servers-CN2M06ITGG1-XP330 Ethernet adapter-10Gb optical port(Intel X710)-dual-port-SFP+(incl. 2 optical modules)-half-height half-length(incl. half-height & full-height brackets)-PCIe 3.0 x8(domestic & overseas) | Current |
| 0231Y830 | function module-Servers-CN2M05ITGH1-XP332 Ethernet adapter-10Gb optical port(Intel XL710)-quad-port-SFP(incl. 4 optical modules)-half-height half-length(incl. half-height & full-height brackets)-PCIe 3.0 x8(domestic & overseas) | Current |
| 0256Y025 | RAID card module-2288H V6-9500-8e-PCIE 4.0 X8-Vendor ID 1000-Device ID 00E6-1-Subvendor ID 1000-Subdevice ID 4080-12G SAS RAID-x8 PCIe 4.0-9500-8e SAS RAID Card,SAS3808,No CacheVault,12Gb/s SAS,6Gb/s SATA,PCIe(NVMe)-9500-8e | Current |
| 0256Y058 | RAID card module-Public Module-9600-16e-PCIE 4.0 X8-Vendor ID 1000-Device ID 00A5-1-Subvendor ID 1000-Subdevice ID 4680-24G SAS RAID card-SAS4016,16 external phy,No CacheVault,no RAID-9600-16e-Chinese documentation | Current |
| 0257Y052 | PCIe-GPU card-2288H V7-BC3A164GPU64-NVIDIA-Tesla A16 PCIe compute card-64GB-PCIe 4.0 x16-4GPU dedicated | Current |
| 0257Y056 | PCIe-GPU card-2288H V7-BC3A100GPU80-NA010 PCIe compute card-80GB-PCIe 4.0 x16 | Current |
| 0257Y057 | PCIe-GPU card-2288H V7-BC4A800GPU80-NVIDIA-Tesla A800 PCIe compute card-80GB-PCIe 4.0 x16 | Current |
| 0257Y058 | PCIe-GPU card-2288H V7-BC3A16GPU64-NA016 PCIe compute card-64GB-PCIe 4.0 x16 | Current |
| 0257Y099 | PCIe-network adapter-2288H V6-E810XXVDA2G1P5-network adapter-25G optical port(E810XXVDA2G1P5 978333)-dual-port-SFP28(optical module not included)-PCIE 4.0 X8-8086-159b|0003-2-with driver package | Current |
| 0257Y101 | PCIe-network adapter-2288H V6-E810CQDA2-network adapter-100G optical port(E810CQDA2G2P5 99A454)-dual-port-QSFP28(optical module not included)-PCIE 4.0 X16-8086-1592|0002-2-with driver package | Current |
| 0257Y102 | PCIe-network adapter-2288H V6-MCX631102AN-ADAT-network adapter-25 GE-64bit-SFP28-2-PCIE 4.0 x8-15b3-101f-2-with driver package | Current |
| 0257Y109 | PCIe-network adapter-2288H V6-LPE31000-AP-Emulex -FC HBA card-16Gb/s(LPe31000)-single-port-SFP+(incl. 1 multimode optical modules)-PCIE 3.0 x8-Vendor ID 10DF-Device ID E300-1-Subvendor ID 10DF-Subdevice ID E311-with driver package | Current |
| 0257Y110 | PCIe-network adapter-2288H V6-LPe31002-AP-Emulex -FC HBA card-16Gb/s(LPe31002)-dual-port-SFP+(incl. 2 multimode optical modules)-PCIE 3.0 x8-Vendor ID 10DF-Device ID E300-2-Subvendor ID 10DF-Subdevice ID E310-with driver package | Current |
| 0257Y112 | PCIe-network adapter-2288H V6-LPe32002-AP-Emulex -FC HBA card-32Gb/s(LPe320PCIE 3.0 x8-Vendor ID 10DF-Device ID E300-2-Subvendor ID 10DF-Subdevice ID E30002)-dual-port-SFP+(incl. 2 multimode optical modules)--with driver package | Current |
| 0257Y114 | PCIe-network adapter-2288H V6-MCX653105A-HDAT-Infiniband MCX653105A-HDAT-200Gb/s-64bit-QSFP56-1port-PCIE 4.0 x16-Vendor ID 15b3-Device ID 101b-1-Subvendor ID 15b3-Subdevice ID 0007-with driver package | Current |
| 0257Y115 | PCIe-network adapter-2288H V6-BCM95719A1904AC-BCM95719A1904AC network adapter-GE-64bit-4*1000BASE-T-4-PCIE 2.0 x4-14e4-1657-4-with driver package | Current |
| 0257Y116 | PCIe-network adapter-2288H V6-X710T2L-10Gb/s-64bit-10GBASE-T-2 ports-PCIE 3.0 x8-8086-15ff-2-with driver package | Current |
| 0257Y117 | PCIe-network adapter-2288H V6-E810XXVDA4-network adapter-25G optical port(E810XXVDA4G2P5 99A2H8)-quad-port-SFP28(optical module not included)-PCIE 4.0 X16-8086-1593|0005-4-full-height half-length-with driver package | Current |
| 0257Y120 | PCIe-network adapter-2288H V6-X2522-25G-Plus-network adapter-25 Gigabit-64bit-SFP28-2 ports-PCIE 3.0 x8-1924-0b03-2-with driver package | Current |
| 0257Y122 | PCIe-network adapter-5885H V7-LPE35000-AP-Emulex -HBA Card LPE35000-AP-FC single-port-32Gb/s-PCIE 4.0 x8-Vendor ID 10DF-Device ID F400-1-with driver package | Current |
| 0257Y123 | PCIe-network adapter-5885H V7-LPE35002-AP-Emulex -HBA Card LPE35002-AP-FC dual-port-32Gb/s-PCIE 4.0 x8-Vendor ID 10DF-Device ID F400-2-with driver package | Current |
| 0257Y125 | PCIe-network adapter-5885H V7-QLE2772-CEM-BK-Qlogic-HBA Card QLE2772-CEM-BK-FC dual-port-32Gb/s-PCIE 4.0 x8-Vendor ID 1077-Device ID 2281-2-with driver package | Current |
| 0257Y129 | PCIe-GPU card-2288H V7-BC3A10GPU24-NA01 PCIe compute card-24GB-PCIe 4.0 x16 | Current |
| 0257Y150 | PCIe-network adapter-2288H V6-MCX623106AN-CDAT-network adapter-100Gb optical port(MCX623106AN-CDAT)-dual-port-QSFP56(optical module not included)-half-height half-length-PCIE 4.0 x16-15b3-101d-2-with driver package | Current |
| 0257Y151 | PCIe-network adapter-2288H V6-BCM957412A4120AC-network adapter-10 Gigabit-64bit-SFP+-2-PCIE 3.0 x8-14e4-16d6-2-with driver package | Current |
| 0257Y152 | PCIe-network adapter-2288H V6-N25GPCIE03-network adapter-25Gb optical port(BCM957414A4142CC)-dual-port-SFP28(optical module not included)-PCIE 3.0 x8-14e4-16d7-2-with driver package | Current |
| 0257Y237 | PCIe-network adapter-2288H V6-RP1000P2SFP-A03-network adapter-10Gb/s-64bit-SFP+-2-PCIE 3.0 x8-Vendor ID 8088-Device ID 1001-2-Subvendor ID 8088-Subdevice ID 0300-with driver package | Current |
| 0257Y246 | PCIe-IB card-G8600 V7-MCX755106AS-HEAT-Infiniband MCX755106AS-HEAT-200Gb/s NDR200 IB,dual-port QSFP112-PCIE 5.0 x16-Vendor ID 15B3-Device ID 1021-2-Subvendor ID 15B3-Subdevice ID 0022(optical module not included) | Current |
| 0257Y299 | PCIe-network adapter-2288H V6-SF400T-network adapter-1 GE-64 bitbit-RJ45-4 Ports-PCIE 2.0 x4-8088-0103-4-with driver package | Current |
| 0257Y300 | PCIe-network adapter-2288H V6-SF200T-network adapter-1Gb/s-64bit-RJ45-2-PCIE 2.0 x4-8088-0101-2-with driver package | Current |
| 0257Y302 | PCIe-network adapter-2288H V6-LPE36002-LPe36002-AP-FC HBA card-64Gb/s-dual-port-PCIE 4.0 x8-Vendor ID 10df-Device ID f400-2-Subvendor ID 10df-Subdevice ID f404-with driver package | Current |
| 0257Y374 | PCIe-GPU card-2288H V7-BC23GPUNVL20-NL02 GPU accelerator card-48GB GDDR6 Memory/864GB/s Memory Bandwidth/PCIE 4.0 x16-10DE-26BA-1/350W | Current |
| 0257Y390 | PCIe-network adapter-2288H V7-MCX75310AAS-NEAT-IB card-Infiniband MCX75310AAS-NEAT-NDR/NDR200/HDR100/EDR IB single-port OSFP-400Gb/s-PCIE 5.0 x16-Vendor ID 15B3-Device ID 1021-1-Subvendor ID 15B3-Subdevice ID 0023-with driver package | Current |
| 0257Y391 | PCIe-network adapter-2288H V7-MCX75310AAS-HEAT-IB card-Infiniband MCX75310AAS-HEAT-200Gb/s NDR200 IB,single-port OSFP-PCIE 5.0 x16-Vendor ID 15B3-Device ID 1021-1-Subvendor ID 15B3-Subdevice ID 0029-with driver package | Current |
| 0257Y476 | PCIe-network adapter-2288H V7-BCM957608-P2200GQF00-network adapter-200 Gigabit-64bit-QSFP56-2 ports-PCIE 5.0 x16-Vendor ID 14e4-Device ID 1760-2-Subvendor ID 14e4-Subdevice ID 9120-with driver package | Current |
| 0257Y506 | PCIe-GPU card-2258 V7-NVIDIA L2 GPU-GPU card-NVIDIA L2 GPU Accelerator-PN:900-2G193-0030-000/24GB GDDR6 Memory/300GB/s peak Memory Bandwidth/PCIE 4.0 x16-10DE-27B6-1,72W/HHHL,single-slot/Passive cooling-English documentation-No Cable | Current |
| 0257Y510 | PCIe-GPU card-2288H V7-Biren 110E-GPU card-Bili 110E generic GPU PCIe-half-height half-length/PCIE 5.0 x16-1EE0-0020-1,66W/single-slot-32 GB LPDDR5-Chinese documentation-HHHL | Current |
| 0257Y516 | PCIe-network adapter-2258 V7-BCM957504-P425G-network adapter-25G(BCM957504-P425G)-64bit-SFP28(optical module not included)-4 ports-PCIE 4.0 x16-Vendor ID 14e4-Device ID 1751-4-Subvendor ID 14e4-Subdevice ID 4250 | Current |
| 0257Y520 | PCIe-network adapter-2288H V7-BCM957508-P2100G-network adapter-100Gb optical port-dual-port-QSFP28-half-height half-length-PCIE 4.0 x16-Vendor ID 14e4-Device ID 1750-2-Subvendor ID 14e4-Subdevice ID 2100 | Current |
| 0257Y551 | PCIe-network adapter-G5500 V7-BCM957608-P1400GDF00-network adapter-400 Gigabit-64bit-QSFP-DD-1 port-PCIE 5.0 x16-Vendor ID 14e4-Device ID 1760-1-Subvendor ID 14e4-Subdevice ID 9140 | Current |
| 0257Y577 | PCIe-network adapter-2288H V7-FF5025-DDATACXX-network adapter-25 GE-64bit-SFP28-2-PCIE 4.0 X8-Vendor ID 8088-Device ID 5025-2-Subvendor ID 8088-Subdevice ID 1000 | Current |
| 0257Y584 | PCIe-GPU card-2288H V7-Intel Flex 170V-GPU card-Intel Data Center GPU Flex 170V-16GB Memory/Bandwidth/Switch 4.0 x16-8086-4FA0-1/PCIE 1.0 x1-8086-56C2-1,150W/SingleSlot-English documentation-No Cable-Full Height,Passive cooling | Current |
| 0257Y665 | PCIe-network adapter-2258 V7-E610XT2M5-PCIE 4.0 X4-Vendor ID 8086-Device ID 57b0-2-Subvendor ID 8086-Subdevice ID 0002 | Current |
| 0257Y821 | PCIe-network adapter-2258 V7-E835XXVDA2M-network adapter-2*25GE-64bit-SFP28-2 Ports-PCIE 4.0 X8-Vendor ID 8086-Device ID 124A-2-Subvendor ID 8086-Subdevice ID 0008-half-height half-length | Current |
| 0302Y043 | manufactured board-Public Module-CN21ITGBA1-XP210 I350 2*GE PCIE standard network adapter-PCIE 2.0 X4-Vendor ID 8086-Device ID 1521-2-Subvendor ID 1f24-Subdevice ID 2000-1*2 | Current |
| 0302Y044 | manufactured board-Public Module-CN21ITGC1-XP212 I350 4*GE standard network adapter-PCIE 2.0 X4-Vendor ID 8086-Device ID 1521-4-Subvendor ID 1f24-Subdevice ID 2001-1*2 | Current |
| 0302Y046 | manufactured board-Public Module-CN21ITGG1-XP330 Ethernet adapter-10Gb optical port(Intel X710)-dual-port-SFP+(optical module not included)-PCIE 3.0 X8-Vendor ID 8086-Device ID 1572-2-Subvendor ID 1f24-Subdevice ID 2003-1*2 | Current |
| 0302Y047 | manufactured board-Public Module-CN21ITGH1-XP332 Ethernet adapter-10Gb optical port(Intel XL710)-quad-port-SFP+(optical module not included)-PCIE 3.0 X8-Vendor ID 8086-Device ID 1572-4-Subvendor ID 1f24-Subdevice ID 2004-1*2 | Current |
| 06030382 | other board card-HBA Card QLE2692-CEM-BK-FC dual-port-16Gb/s-PCIE 3.0 x8-Vendor ID 1077-Device ID 2261-2-incl. multimode optical module-Chinese & English documentation-half-height half-length | Current |
| 06030462 | other board card-HBA Card LPe31000-AP-FC single-port-16Gb/s-PCIE 3.0 x8-Vendor ID 10DF-Device ID E300-1-Subvendor ID 10DF-Subdevice ID E311-English documentation-1pcs low-profile bracket-half-height half-length | Current |
| 0631Y046 | network adapter-25G(E810XXVDA2G1P5 978333)-64bit-SFP28(optical module not included)-2 ports-PCIE 4.0 X8-8086-159b|0003-2-without driver | Current |
| — | network adapter-25 Gigabit-64bit-SFP28(optical module not included)-2 Ports-PCIE 3.0 x8-15b3-1017-2-with driver package-one bracket included with incoming material | Current |
| 0231Y457 | function module-2288HV6-CN2M11ITGG-network adapter-40 Gigabit(EXL710QDA2G1P5)-64bit-QSFP+(optical module not included)-2 Ports-PCIE 3.0 x8-8086-1583 | EOP |
| 0231Y815 | function module-Servers-BC5M02ETHE1-XP380 Ethernet adapter-25GE optical port(Mellanox CX-4 Lx)-dual-port-SFP28(optical module not included)-half-height half-length-full-height bracket-PCIe 3.0 x8 | EOM |
| 0231Y817 | function module-Servers-BC5M04ETHE1-XP380 Ethernet adapter-25GE optical port(Mellanox CX-4 Lx)-dual-port-SFP28(optical module not included)-half-height half-length(incl. half-height & full-height brackets(loose))-PCIe 3.0 x8 | EOM |
| 0231Y992 | function module-Servers-BC5M10ETHE1-XP380 Ethernet adapter-25GE optical port(Mellanox CX-4 Lx)-dual-port-SFP28(incl. 2*10GE optical module)-half-height half-length-full-height bracket-PCIe 3.0 x8 | EOM |
| 0231Y993 | function module-Servers-BC5M11ETHE1-XP380 Ethernet adapter-25GE optical port(Mellanox CX-4 Lx)-dual-port-SFP28(incl. 2*25GE optical module)-half-height half-length-full-height bracket-PCIe 3.0 x8 | EOM |
| 0257Y053 | PCIe-GPU card-2288H V7-BC3A304GPU24-NVIDIA-Tesla A30 PCIe compute card-24GB-PCIe 4.0 x16-4GPU dedicated | EOP |
| 0257Y054 | PCIe-GPU card-2288H V7-BC3A404GPU48-NA04 PCIe compute card-48GB-PCIe 4.0 x16-4GPU dedicated | EOP |
| 0257Y055 | PCIe-GPU card-2288H V7-BC3A100GPU40-NA010 PCIe compute card-40GB-PCIe 4.0 x16 | EOP |
| 0257Y059 | PCIe-GPU card-2288H V7-BC3A30GPU24-NA03 PCIe compute card-24GB-PCIe 4.0 x16 | EOP |
| 0257Y060 | PCIe-GPU card-2288H V7-BC3A40GPU48-NVIDIA-Tesla A40 PCIe compute card-48GB-PCIe 4.0 x16 | EOP |
| 0257Y094 | PCIe-network adapter-2288H V6-MCX4121A-ACAT-Ethernet adapter-25Gb optical port(Mellanox CX4-lx EN)-dual-port-SFP28(optical module not included)-PCIE 3.0 X8-15b3-1015-2-with driver package | EOP |
| 0257Y095 | PCIe-network adapter-2288H V6-MCX512A-ACAT-network adapter-25Gb optical port(MCX512A-ACAT)-dual-port-SFP28(optical module not included)-PCIE 3.0 x8-15b3-1017-2-Subvendor ID 15b3-Subdevice ID 0020-with driver package | EOP |
| 0257Y096 | PCIe-network adapter-2288H V6-MCX512A-ACUT-network adapter-25Gb optical port(MCX512A-ACUT)-dual-port-SFP28(optical module not included)-PCIE 3.0 x8-15b3-1017-2-with driver package | EOP |
| 0257Y098 | PCIe-network adapter-2288H V6-XXV710DA2-Ethernet adapter-25Gb optical port(Intel-XXV710)-dual-port-SFP28(optical module not included)-PCIE 3.0 X8-8086-158b-2-with driver package | EOM |
| 0257Y100 | PCIe-network adapter-2288H V6-MCX515A-CCAT-network adapter-100Gb optical port(MCX515A-CCAT)-single-port-QSFP28(optical module not included)-PCIE 3.0 x16-15b3-1017-1-with driver package | EOM |
| 0257Y111 | PCIe-network adapter-2288H V6-LPe32000-AP-Emulex -FC HBA card-32Gb/s(LPe32000)-single-port-SFP+(incl. 1 multimode optical modules)-PCIE 3.0 x8-Vendor ID 10DF-Device ID E300-1-Subvendor ID 10DF-Subdevice ID E301-with driver package | EOP |
| 0257Y113 | PCIe-network adapter-2288H V6-MCX653105A-ECAT-Infiniband MCX653105A-ECAT-HDR100/EDR IB single-port-100Gb/s-PCIE 4.0 x16-Vendor ID 15b3-Device ID 101b-1|2-Subvendor ID 15b3-Subdevice ID 0006-with driver package | EOM |
| 0257Y124 | PCIe-network adapter-5885H V7-QLE2770-CEM-BK-Qlogic-HBA Card QLE2770-CEM-BK-FC single-port Port-32Gb/s-PCIE 4.0 x8-Vendor ID 1077-Device ID 2281-1-with driver package | EOP |
| 0257Y178 | PCIe-network adapter-2288H V6-MCX516A-CCAT-network adapter-100 Gigabit-64bit-QSFP28(optical module not included)-2 Ports-PCIE 3.0 x16-Vendor ID 15b3-Device ID 1017-2-Subvendor ID 15b3-Subdevice ID 0007-with driver package | EOP |
| 0257Y209 | PCIe-network adapter-2288H V6-MCX75310AAS-NEAT-MELLANOX MCX75310AAS-NEAT NDR/NDR200/HDR100/EDR IB card-400Gb/s-single-port-OSFP-PCIE 5.0 x16-Vendor ID 15B3-Device ID 1021-1-Subvendor ID 15B3-Subdevice ID 0023-(only supports IB mode) | EOP |
| 0257Y211 | PCIe-network adapter-2288H V6-MCX75310AAS-HEAT-IB card-Infiniband MCX75310AAS-HEAT-200Gb/s NDR200 IB,single-port OSFP-PCIE 5.0 x16-Vendor ID 15B3-Device ID 1021-1-Subvendor ID 15B3-Subdevice ID 0029-with driver package-(only supports IB mode) | EOP |
| 0257Y230 | PCIe-network adapter-2288H V6-MCX653106A-ECAT-other board card-Infiniband MCX653106A-ECAT-HDR100/EDR 100GbE IB dual-port-100Gb/s-PCIE 4.0 x16-Vendor ID 15b3-Device ID 101b-2-Subvendor ID 15b3-Subdevice ID 0008-with driver package | EOP |
| 0257Y280 | PCIe-GPU card-2288H V7-BC3H100GPU8003-NH010P compute accelerator card-80GB-PCIe 5.0 x16-overseas dedicated | EOP |
| 0257Y282 | PCIe-GPU card-2288H V7-BC3H800GPU8003-NH080P compute accelerator card-80GB-PCIe 5.0 x16 | EOP |
| 0257Y307 | PCIe-GPU card-2288H V7-BC2NL4GPU81-NVIDIA L4 PCIe accelerator card-24GB-PCIe 4.0 x16 | EOP |
| 06030381 | other board card-HBA Card QLE2690-HUA-SP-FC single-port-16Gb/s-PCIE 3.0 x8-Vendor ID 1077-Device ID 2261-1-no-multimode optical module-half-height half-length | EOM |
| 06030390 | other board card-HBA Card QLE2740-HUA-SP-FC single-port-32Gb/s-PCIE 3.0 x8-Vendor ID 1077-Device ID 2261-1-no-multimode optical module-half-height half-length | EOM |
| 06030392 | other board card-HBA Card QLE2742-HUA-SP-FC dual-port-32Gb/s-PCIE 3.0 x8-Vendor ID 1077-Device ID 2261-2-no-multimode optical module-half-height half-length | EOM |
| 0632Y012-001 | GPU card-GPU-Data Center A2 PCIe-PN:900-2G179-0020-101/16GB Memory/200GB/s Bandwidth/PCIE 4.0 x8-10DE-25B6-1,60W/singleSlot/PassiveCooling-no-No Cable | EOM |
| 3406Y008 | High Speed Transceiver,SFP28,850nm,25G,-8.4dBm,2.4dBm,-10.3dBm,LC,MM,0.1km,Original 34061254 split | Current Field replaceable |
| 3406Y006 | XFP|SFP+ Transceiver,SFP+,850nm,10Gb/s,-7.3dBm,-1dBm,-9.9dBm,LC,0.3km | Current Field replaceable |
| 34061089 | High Speed Transceiver,QSFP28,850nm,100G,-8.4dBm,2.4dBm,-10.3dBm,MPO,MM,0.1km,OM4 | Current Engineer replace |
| 34061254 | High Speed Transceiver,SFP28,850nm,25G,-8.4dBm,2.4dBm,-10.3dBm,LC,MM,0.1km | Current Field replaceable |
| 3406Y011 | High Speed Transceiver,QSFP28,850nm,100G,-8.4dBm,2.4dBm,-10.3dBm,MPO,MM,0.1km,OM4 Original 34061089 split | Current Field replaceable |
| 3406Y009 | High Speed Transceiver,QSFP+,850nm,41.25Gbps,-7.6dBm,0.5dBm,-9.5dBm,MPO,0.15km,Original 34060662-002 split | Current Field replaceable |
| 34060495 | XFP|SFP+ Transceiver,SFP+,1310nm,10Gb/s,-8.2dBm,0.5dBm,-12.6dBm,LC,SM,10km | Current Field replaceable |
| 3406Y007 | XFP|SFP+ Transceiver,SFP+,1310nm,10Gb/s,-8.2dBm,0.5dBm,-12.6dBm,LC,10km | Current Field replaceable |
| 0631Y005 | Network Card,25Gb/s,64bit,SFP28,2 ports,PCIE 4.0 x8-15b3-101f-2,No Driver CD,OCP | Current Field replaceable |
| 0631Y027 | Network Card,100GE,64bit,QSFP56(without Optical Transceiver),2 Ports,PCIE 4.0 x16-15b3-101d-2,No Driver CD | Current Field replaceable |
| 0302Y437 | Manufactured Board,XP380,BC51ETHE3,Ethernet Adapter,25GE(Mellanox CX-4 Lx),Dual-Port,SFP28(without Optical Transceiver),PCIE 3.0 x8-Vendor ID 15b3-Device ID 1015-2-Subvendor ID 1f24-Subdevice ID 2005,1*2 | Current Field replaceable |
| 0631Y037 | Network Card,10 Gigabit,64bit,SFP+,2,PCIE 3.0 x8-14e4-16d6-2,No Driver CD | Current Field replaceable |
| 0631Y035 | Network Card,10 Gigabit,64bit,PCIE 3.0 x8-8086-15FF-2,No Driver CD,OCP | Current Field replaceable |
| 06310219 | Network Card,25G(E810XXVDA2G1P5 978333),64bit,SFP28(without Optical Transceiver),2 ports,PCIE 4.0 X8-8086-159b|0003-2,No Driver CD | Current Field replaceable |
| 06310156 | Network Card,25 Gigabit,64bit,SFP28(without Optical Transceiver),2 Ports,PCIE 3.0 x8-15b3-1017-2-Subvendor ID 15b3-Subdevice ID 0020,No Driver CD,with 1pcs short bracket | Current Field replaceable |
| 06310191 | Network Card,25 Gigabit,64bit,SFP28,2 ports,PCIE 3.0 X8-15b3-1015-2,No Driver CD | Current Field replaceable |
| 0302Y049 | Manufactured Board,Public Module,BC51ETHK1,XP382 Ethernet Adapter,25GE(Mellanox CX-5 Lx),Dual-Port,SFP28(without Optical Transceiver),PCIE 3.0 x8-Vendor ID 15b3-Device ID 1017-2-Subvendor ID 1f24-Subdevice ID 2006,1*2 | Current Field replaceable |
| 06310224 | Network Card,10GE,64bit,10GBASE-T,2 ports,PCIE 3.0 x8-8086-15ff-2,No Driver CD | Current Field replaceable |
| 06310169 | Network Card,25 Gigabit,64bit,SFP28(without Optical Transceiver),2 Ports,PCIE 3.0 x8-15b3-1017-2,No Driver CD-A baffle plate is delivered with the incoming material | Current Field replaceable |
| 06310149 | Network Card,100 Gigabit,64bit,QSFP28(without Optical Transceiver),1 ports,PCIE 3.0 x16-15b3-1017-1-Subvendor ID 15b3-Subdevice ID 0006,No Driver CD | Current Field replaceable |
| 0631Y040 | Network Card,25 GE,64bit,SFP28,2,PCIE 4.0 x8-15b3-101f-2,No Driver CD | Current Field replaceable |
| 06310221 | Network Card,25G(E810XXVDA4G2P5 99A2H8),64bit,SFP28(without Optical Transceiver),4 ports,PCIE 4.0 X16-8086-1593|0005-4,No Driver CD | Current Field replaceable |
| 06310220 | Network Card,100G(E810CQDA2G2P5 99A454),64bit,QSFP28(without Optical Transceiver),2 ports,PCIE 4.0 X16-8086-1592|0002-2,No Driver CD | Current Field replaceable |
| 06030393 | Other Cards,HBA Card LPe32002-AP,FC Double Ports-32Gb/s,PCIE 3.0 x8-Vendor ID 10DF-Device ID E300-2-Subvendor ID 10DF-Subdevice ID E300,English doc,1pcs short bracket,half width half length-Prohibition of separate shipment | Current Field replaceable |
| 06030391 | Other Cards,HBA Card LPe32000-AP,FC Single Port-32Gb/s,PCIE 3.0 x8-Vendor ID 10DF-Device ID E300-1-Subvendor ID 10DF-Subdevice ID E301,English doc,1pcs short bracket,half width half length-Prohibition of separate shipment | Current Field replaceable |
| 0603Y023 | Other Cards,HBA Card QLE2772-CEM-BK,FC Double Ports-32Gb/s,PCIE 4.0 x8-1077-2281-2,Chinese and English doc,half width half length | Current Field replaceable |
| 06030463 | Other Cards,HBA Card LPe31002-AP,FC Double Ports-16Gb/s,PCIE 3.0 x8-Vendor ID 10DF-Device ID E300-2-Subvendor ID 10DF-Subdevice ID E310,English doc,Full-height and half-height bracket,half width half length | Current Field replaceable |
| 06030516 | IB Card,Infiniband MCX653105A-ECAT,HDR100/EDR single-port -100Gb/s- PCIE 4.0 x16-Vendor ID 15b3-Device ID 101b-1|2-Subvendor ID 15b3-Subdevice ID 0006-tall bracket,English doc | Current Field replaceable |
| 0603Y018 | IB Card,Infiniband MCX653105A-HDAT,200Gb/s-64bit-QSFP56-1port,PCIE 4.0 x16-Vendor ID 15b3-Device ID 101b-1-Subvendor ID 15b3-Subdevice ID 0007,Chinese and English doc | Current Field replaceable |
| 0632Y027 | Video Card,GPU-Data Center A800 PCIe,PN:900-21001-0030-100/80GB HBM2e Memory/ 1.9TB/s Bandwidth/ PCIE 4.0 x16-10DE-20F5-1,300W/ DualSlot/PassiveCooling,NULL,1PCS Cable | Current Field replaceable |
| 3406Y001 | Active Optical Cable Assembly,200Gb/s to 2x100Gb/s, QSFP56 to 2xQSFP56,IB HDR, 200Gpbs, LSZH, black pulltab,0.005km | Current Field replaceable |
| 0632Y074 | GPU Card,NVIDIA L20 GPU Accelerator,PN:900-2G133-00A0-000 / 48GB GDDR6 Memory / 864GB/s Memory Bandwidth /PCIE 4.0 x16-10DE-26BA-1 /350W,No NVLink,English doc,Dual slot,Passive | Current Field replaceable |
| 0632Y075 | GPU Card,NVIDIA L2 GPU Accelerator,PN:900-2G193-0030-000/24GB GDDR6 Memory/ 300GB/s peak Memory Bandwidth/ PCIE 4.0 x16-10DE-27B6-1,72W/ HHHL, single-slot/Passive cooling,English doc,No Cable | Current Field replaceable |
| 3406Y033 | High Speed Transceiver,SFP28,850nm,25G,-8.4dBm,2.4dBm,-10.3dBm,LC,MM,0.1km,sont split | Current Field replaceable |
| 3406Y023 | High Speed Transceiver,QSFP56,850nm,200Gbps,-5.9dBm,4dBm,-4.4dBm,MPO12/UPC,MM,0.1km,8636 | Current Field replaceable |
| 3406Y012 | High Speed Transceiver,OSFP,850nm,400Gbps,-4.6dBm,4dBm,-4.4dBm,MPO-12/APC,MM,0.05km,OM4 Dedicated to IB NDR HCA | Current Engineer replace |
| 0257Y106 | PCIe-NIC Card,2288H V6,MCX631432AN-ADAB,MCX631432AN-ADAB Ethernet Adapter,25GE(Mellanox CX6),Dual-Port,SFP28,PCIE 4.0 x8-15b3-101f-2,With driver pack-OCP | Current Field replaceable |
| 0603Y037 | Other Cards,HBA Card LPe36002-AP,FC dual Ports-64Gb/s,PCIE 4.0 x8-Vendor ID 10df-Device ID f400-2-Subvendor ID 10df-Subdevice ID f404,Chinese and English doc,half width half length | Current Field replaceable |
| 06310158 | Network Card,100 Gigabit,64bit,QSFP28(without Optical Transceiver),2 Ports,PCIE 3.0 x16-Vendor ID 15b3-Device ID 1017-2-Subvendor ID 15b3-Subdevice ID 0007,No Driver CD | Current Field replaceable |
| 06310132 | Network Card,XXV710DA2G1P5 948661-25 Gigabit,64bit,SFP28,2 ports,PCIE 3.0 X8-8086-158b-2,No Driver CD | Current Field replaceable |
| 06310148 | Network Card,25 Gigabit,64bit,SFP28(without Optical Transceiver),2 Ports,PCIE 3.0 x8-14e4-16d7-2,No Driver CD | Current Field replaceable |
| 0631Y021 | Network Card,25 Gigabit,64bit,SFP28,2 ports,PCIE 3.0 x8-1924-0b03-2,No Driver CD | Current Field replaceable |
| 0603Y034 | IB Card,Infiniband MCX683105AN-HDAT,200Gb/s-64bit-QSFP56-1port,PCIE 4.0 x16-15b3-101d-1,Chinese and English doc | Current Field replaceable |
| 0257Y512 | PCIe-NIC Card,2288H V6-32dimm,MCX631102AN-ADAT,PCIe-NIC Card,25 GE,64bit,SFP28,dual port,PCIE 4.0 x8-Vendor ID 15b3-Device ID 101f-2-Subvendor ID 15b3-Subdevice ID 0001 | Current Field replaceable |
| 0631Y103 | Network Card,10Gb/s,64bit,SFP+,2,PCIE 3.0 x8-Vendor ID 8088-Device ID 1001-2-Subvendor ID 8088-Subdevice ID 0300,No Driver CD | Current Field replaceable |
| 0257Y366 | PCIe-NIC Card,5288 V6,BCM957414N4140C,BCM957414N4140C Ethernet Adapter,2*25GE(Broadcom BCM57414),Dual-Port,SFP28,PCIE 3.0 x8-14e4-16d7-2,Without driver package | Current Field replaceable |
| 0603Y021 | Other Cards,HBA Card LPE35002-AP,FC Double Ports--32Gb/s,PCIE 4.0 x8-10df-f400-2,Chinese and English doc,half width half length | Current Field replaceable |
| 0257Y580 | PCIe-NIC Card,2288H V7,MCX623106AN-CDAT_06,Network Card,100GE,64bit,QSFP56(without Optical Transceiver),2 Ports,PCIE 4.0 x16-Vendor ID 15b3-Device ID 101d-2-Subvendor ID 15b3-Subdevice ID 0064 | Current Field replaceable |
| 0257Y682 | PCIe-NIC Card,2288H V7,MCX631432AS-ADAB,25Gb/s-64bit-SFP28-2 ports-PCIE 4.0 X8-Vendor ID 15b3-Device ID 101f-2-Subvendor ID 15b3-Subdevice ID 0007-OCP 3.0 | Current Field replaceable |
| 0257Y542 | PCIe-NIC Card,2288H V7,MCX623106AN-CDAT,NIC-100Gb(MCX623106AN-CDAT)-2 Ports-QSFP56(without Optical Transceiver)-PCIE 4.0 x16-15b3-101d-2 | Current Field replaceable |
| 0257Y579 | PCIe-NIC Card,2288H V7,MCX631102AS-ADAT,Network Card,25 GE,64bit,SFP28,2,PCIE 4.0 x8-Vendor ID 15b3-Device ID 101f-2-Subvendor ID 15b3-Subdevice ID 0012 | Current Field replaceable |
| 0603Y020 | Other Cards,HBA Card LPE35000-AP,FC single Port-32Gb/s,PCIE 4.0 x8-10df-f400-1,Chinese and English doc,half width half length | Current Field replaceable |
| 0257Y446 | PCIe-NIC Card,2288DX V7,SF200T,Network Card,1 GE,64bit,RJ45,2 Ports,PCIE 2.0 x4-8088-0101-2 | Current Field replaceable |
| 0632Y087 | GPU Card,Biren110E GPGPU PCIe Card, HHHL/PCIE 5.0 x16-1EE0-0020-1,66W/Singleslot,32 GB LPDDR5,Chinese doc | Current Field replaceable |
| 0257Y621 | PCIe-NIC Card,2288H V6,BCM957508-P2100G,Network Card,100 Gigabit,64bit,QSFP28,2 ports,PCIE 4.0 x16-14e4-1750-2,With driver pack | Current Field replaceable |
| 0603Y054 | IB Card,Infiniband MCX755106AS-HEAT,2*200Gb/s NDR200 IB, Dual port QSFP112,PCIE 5.0 x16-Vendor ID 15B3-Device ID 1021-2-Subvendor ID 15B3-Subdevice ID 0022,English doc | Current Field replaceable |
| P/N | Description / Specification | Status |
|---|---|---|
| 0257Y104 | PCIe-network adapter-2288H V6-X710DA2OCPV3-network adapter-2*10GE-64bit-SFP+(without optical module)-2 ports-PCIE 3.0 x8-8086-1572-2-OCP 3.0-with driver package | Current |
| 0257Y105 | PCIe-network adapter-2288H V6-X710T2LOCPV3-X710T2LOCPV3 Ethernet adapter-2*10GE(Intel X710)-dual-port-RJ45-PCIE 3.0 x8-8086-15FF-2-with driver package-OCP | Current |
| 0257Y106 | PCIe-network adapter-2288H V6-MCX631432AN-ADAB-MCX631432AN-ADAB Ethernet adapter-25GE(Mellanox CX6)-dual-port-SFP28-PCIE 4.0 x8-15b3-101f-2-with driver package-OCP | Current |
| 0257Y107 | PCIe-network adapter-2288H V6-E810XXVDA2OCP3G-Ethernet adapter-25GE(Intel E810)-dual-port-SFP28-PCIE 4.0 x8-Vendor ID 8086-Device ID 159b-2-Subvendor ID 8086-Subdevice ID 0005-with driver package-OCP | Current |
| 0257Y108 | PCIe-network adapter-2288H V6-BCM957414N4140C-Ethernet adapter-2*25GE(Broadcom BCM57414)-dual-port-SFP28-PCIE 3.0 x8-14e4-16d7-2,OCP 3.0-with driver package | Current |
| 0257Y131 | PCIe-network adapter-2288H V6-BCM957508-N2100G-network adapter-100 Gigabit-64bit-QSFP28-2 ports-PCIE 4.0 x16-14e4-1750-2,OCP-with driver package | Current |
| 0302Y054 | manufactured board-JDM-Public Module-BC53ETHF-XC310 GE350-T2 OCP3.0 Ethernet adapter-2*GE(I350)-dual-port-RJ45,PCIE 2.1 x4-Vendor ID 8086-Device ID 1521-2-Subvendor ID 1f24-Subdevice ID 200b-1*4 | Current |
| 0302Y055 | manufactured board-JDM-Public Module-BC53ETHB1-XC382 OCP3.0 Ethernet adapter-25GE(CX5)-dual-port-SFP28(optical module not included)-PCIE 3.0 X8-Vendor ID 15b3-Device ID 1017-2-Subvendor ID 1f24-Subdevice ID 200c-1*4 | Current |
| 0302Y237 | manufactured board-JDM-Public Module-BC53ETHH-XC331 OCP3.0 Ethernet adapter-10GE(BCM57416)-dual-port-RJ45-PCIE 3.0 X8-Vendor ID 14e4-Device ID 16d8-2-Subvendor ID 1f24-Subdevice ID 2010-1*3 | Current |
| 0302Y238 | manufactured board-JDM-Public Module-BC55ETHA-XC385 OCP3.0 Ethernet adapter-25GE(CX6-Lx)-dual-port-SFP28(optical module not included)-PCIE 4.0 X8-Vendor ID 15b3-Device ID 101f-2-Subvendor ID 1f24-Subdevice ID 2011-1*4 | Current |
| 0302Y239 | manufactured board-JDM-Public Module-BC55ETHB-XC381 OCP3.0 Ethernet adapter-25GE(E810)-dual-port-SFP28(optical module not included)-PCIE 4.0 X8-Vendor ID 8086-Device ID 159b-2-Subvendor ID 1f24-Subdevice ID 2012-1*4 | Current |
| 0302Y434 | manufactured board-JDM-Public Module-BC53ETHI-XC386 OCP3.0 Ethernet adapter-25GE(BCM57414)-dual-port-SFP28(optical module not included)-PCIE 3.0 X8-Vendor ID 14e4-Device ID 16d7-2-Subvendor ID 1f24-Subdevice ID 2013-1*4 | Current |
| 0302Y435 | manufactured board-JDM-Public Module-BC53ETHJ-XC333 OCP3.0 Ethernet adapter-10GE(BCM57412)-dual-port-SFP+(optical module not included)-PCIE 3.0 X8-Vendor ID 14e4-Device ID 16d6-2-Subvendor ID 1f24-Subdevice ID 2014-1*4 | Current |
| 0631Y023-002 | network adapter-2*25GE-64bit-SFP28(without optical module)-2 Ports-PCIE 3.0 x8-14e4-16d7-2-without driver-OCP 3.0 | Current |
| 0302Y085 | manufactured board-JDM-Public Module-BC53ETHG-XC383 OCP3.0 Ethernet adapter-10GE(CX-4 Lx)-dual-port-SFP+(optical module not included)-PCIE 3.0 X8-Vendor ID 15b3-Device ID 1015-2-Subvendor ID 1f24-Subdevice ID 200d-1*4 | EOM |
| 0631Y022 | Network Card,2*10GE,64bit,SFP+(without Optical Transceiver),2 ports,PCIE 3.0 x8-8086-1572-2,No Driver CD,OCP 3.0 | Current Field replaceable |
| 0631Y004 | Network Card,25Gb/s,64bit,SFP28,2 ports,PCIE 4.0 x8-Vendor ID 8086-Device ID 159b-2-Subvendor ID 8086-Subdevice ID 0005,No Driver CD,OCP | Current Field replaceable |
| 0631Y023 | Network Card,2*25GE,64bit,SFP28(without Optical Transceiver),2 Ports,PCIE 3.0 x8-14e4-16d7-2,No Driver CD,OCP 3.0 | Current Field replaceable |
| 0631Y043 | Network Card,100 Gigabit,64bit,QSFP28,2 ports,PCIE 4.0 x16-14e4-1750-2,No Driver CD,OCP | Current Field replaceable |
| 0257Y312 | PCIe-NIC Card,2288H V7,MCX623436AN-CDAB,OCP Network card-100 Gigabit-64bit-QSFP28-2 ports-PCIE 4.0 x16-15b3-101d-1|2|4-without driver-without optical module-OCP 3.0,Without driver pack | Current Field replaceable |
| 0257Y311 | PCIe-NIC Card,2288H V7,BCM957414N4140C,OCP Network card-2*25GE-64bit-SFP28(without optical module)-2 Ports-PCIE 3.0 x8-14e4-16d7-2-without driver-OCP 3.0,Without driver package | Current Field replaceable |
| P/N | Description / Specification | Status |
|---|---|---|
| 02313ADY | function module-TS200-2280-BC11TPMC02-TPM2.0 card(SPI)-China dedicated | Current |
| 02313APL | function module-TS200-2280-BC11TPMA02-TPM2.0 card(SPI)-international dedicated | Current |
| 02313KFC | function module-2488H V6-BC11TPMA07-TCM card(SPI) | Current |
| 03028HYW | Manufactured Board,TaiShan 200 (Model 2280),BC11TPMD,TPM2.0 Card(SPI), China Dedicated,5*4 | Current Engineer replace |
| 03024QEJ | Manufactured Board,2288H V5,BC11TPMB,TCM Card(SPI),5*4 | Current Engineer replace |
| 03024QEH | Manufactured Board,2288H V5,BC11TPMA,TPM2.0 Card(SPI), Overseas Dedicated,5*4 | Current Engineer replace |
| P/N | Description / Specification | Status |
|---|---|---|
| 0302012403 | manufactured board-2288H V7-BC15HBBB-12*3.5 inch SAS/SATA pass-through(incl. 4*NVMe)drive backplane-1*2 | NONE |
| 0302012404 | manufactured board-2288H V7-BC15HBBA-8*2.5 inch SAS/SATA standard drive backplane-1*2 | NONE |
| 0302012406 | manufactured board-2288H V7-BC15NHBB-24*NVMe(incl. 8*SAS/SATA)pass-through drive backplane-1*2 | NONE |
| 0302012407 | manufactured board-2288H V7-BC15NHBC-IO3 4*NVMe drive backplane-1*4 | NONE |
| 0302012451 | manufactured board-2288H V7-BC15NHBA-4*SAS+8*NVMe pass-through drive backplane-1*2 | NONE |
| 0302012464 | manufactured board-2288H V7-BC15HBBI-IO3 4*SAS/SATA/NVMe drive backplane-1*4 | NONE |
| 0302013602 | manufactured board-2288H V7-BC15HBBC-24*2.5 inch SAS/SATA pass-through drive backplane-1*2 | NONE |
| 0302Y082 | manufactured board-2288H V7-BC15HBEC-12*3.5inch HDD Expander drive backplane-1*2 | NONE |
| 0302Y083 | manufactured board-2288H V7-BC15HBED-25*2.5inch HDD Expander drive backplane-1*2 | NONE |
| 0302Y125 | manufactured board-2288H V7-BC15NHBI-8*SAS/SATA+16NVME pass-through drive backplane-1*2 | NONE |
| 0302Y258 | manufactured board-2288H V7-BC15NHBK-8*2.5 inch SAS/SATA/NVMe drive backplane-1*2 | NONE |
| 0302Y259 | manufactured board-2288H V7-BC15NHBL-8*3.5 inch SAS/SATA/NVMe drive backplane-1*2 | NONE |
| 0302Y380 | manufactured board-2288H V7-BC15HBEE-12*3.5inch HDD Expander drive backplane(24port)-1*2 | NONE |
| 0302Y650 | manufactured board-2258 V7-BC15NHBR-12*3.5 inch SAS/SATA/NVMe drive backplane-1*2 | NONE |
| 0302Y676 | manufactured board-2258 V7-BC15NHBS-8*2.5 inch SAS/SATA/NVMe hard Raid drive backplane-1*2 | NONE |
| 0302Y683 | manufactured board-2258 V7-BC15HBBS-IO3 4*NVMe drive backplane-1*4 | NONE |
| 0302YADL | manufactured board-2288H V7-BC15NHBIA-8*SAS/SATA+16NVME pass-through drive backplane(supports PCIE 5.0)-1*2 | NONE |
| P/N | Description / Specification | Status |
|---|---|---|
| 02131730 | 2000W platinumAC power supply(model PAC2000S12-BW,interface IEC 320-C14) | Current |
| 0227Y001 | server 1200W platinum DC 48V power supply(requires DC power cord)(model PDC1200S12-PG,interface Phoenix SPT 5/3-H-7,5-ZB model crimp terminal) | Current |
| 02313XSF | server platinum 900W 2.0 versionAC power supply-ST(model PAC900S12-B2,interface IEC 320-C14) | Current |
| 0231Y019 | server platinum 2000W 2.0 versionAC power supply(model PAC2000S12-B1,interface IEC 320-C14) | Current |
| 0231Y020 | server DC power supply-PDC1200S12-CF-68mm-1200W-air-cooled(requires DC power cord)(model PDC1200S12-CF,interface Phoenix SPT 5/3-H-7,5-ZB model crimp terminal) | Current |
| 0231Y021 | HVDC1500WB power supply module(model PHD1500S12-B2,interface Rongfeng RF-203 high-voltage input terminal) | Current |
| 0231Y023 | 3000W titanium AC power supply(model PAC3000S12-T1,interface IEC 320-C20) | Current |
| 0231Y025 | server titanium 2000W AC power supply module(model PAC2000S12-T1,interface IEC 320-C14) | Current |
| 0231Y033 | server platinum 1500W 2.0 versionAC power supply(model PAC1500S12-B1,interface IEC 320-C14) | Current |
| 0231Y034 | 2000W AC power supply module(model PAC2000S12-BE,interface IEC 320-C14) | Current |
| 0231Y265 | 900W titanium AC power supply(model PAC900S12-T1,interface IEC 320-C14) | Current |
| 0231Y493 | server DC power supply-68mm-1200W-air-cooled(incl. DC power cord)(model PDC1200S12-CF1,interface Phoenix SPT 5/3-H-7,5-ZB model crimp terminal) | Current |
| 0231YEKU | primary power supply-XA3000-server titanium 3000W AC power supply(model XA3000,interface IEC 320-C20) | Current |
| 0231Y017 | server platinum 900W 2.0 versionAC power supply(model PAC900S12-B2,interface IEC 320-C14) | EOM |
| 0231Y711 | function module-primary power supply-PAC900S12-B3-server platinum 900W 2.0 versionAC power supply-ST(model PAC900S12-B3,interface IEC 320-C14) | EOP |
| P/N | Description / Specification | Status |
|---|---|---|
| 0255Y695 | SSD module-Servers-M.2 SSD-SATA 6Gb/s-240GB-80.0mm * 22.0mm * 3.58 mm(hot-swappable)-ER3 series | Current |
| 0255Y696 | SSD module-Servers-M.2 SSD-SATA 6Gb/s-240GB-80.0mm * 22.0mm * 3.58 mm(non-hot-swappable)-ER3 series | Current |
| 0255Y697 | SSD module-Servers-M.2 SSD-SATA 6Gb/s-480GB-80.0mm * 22.0mm * 3.58 mm(hot-swappable)-ER3 series | Current |
| 0255Y698 | SSD module-Servers-M.2 SSD-SATA 6Gb/s-480GB-80.0mm * 22.0mm * 3.58 mm(non-hot-swappable)-ER3 series | Current |
| 0255YBWE | SSD module-Servers-M.2 SSD-NVMe PCIe-1920GB-80.0mm * 22.0mm * 3.58 mm(non-hot-swappable)-PJ1 series | Current |
| 0255YCUL | SSD module-Servers-M.2 SSD-NVMe PCIe-960GB-80.0mm * 22.0mm * 3.58 mm(non-hot-swappable)-PJ1 series | Current |
| 0255YCUY | SSD module-Servers-M.2 SSD-NVMe PCIe-480GB-80.0mm * 22.0mm * 3.58 mm(non-hot-swappable)-PM9A3 series | Current |
| 0255YEUU | SSD module-Servers-M.2 SSD-NVMe PCIe-1920GB-80.0mm * 22.0mm * 3.58 mm(non-hot-swappable)-PJ1 series | Current |
| 0255YFBA | SSD module-Servers-M.2 SSD-SATA 6Gb/s-480GB-80.0mm * 22.0mm * 3.58 mm(hot-swappable)-ER3 series | Current |
| 0255YFBP | SSD module-Servers-M.2 SSD-SATA 6Gb/s-480GB-80.0mm * 22.0mm * 3.58 mm(non-hot-swappable)-ER3 series | Current |
| 0255YFDH | SSD module-Servers-M.2 SSD-NVMe PCIe-480GB-80.0mm * 22.0mm * 3.58 mm(non-hot-swappable)-PM9A3 series | Current |
| 0255YGFS | SSD module-Servers-M.2 SSD-NVMe PCIe-960GB-80.0mm * 22.0mm * 3.58 mm-PJ1 series | Current |
| 0255YGFT | SSD module-Servers-M.2 SSD-NVMe PCIe-480GB-80.0mm * 22.0mm * 3.58 mm-PM9A3 series | Current |
| 02313ARC | function module-Public Module-M.2 SSD-SATA 6Gb/s-240GB-80.0mm * 22.0mm * 3.58 mm(hot-swappable) | EOM |
| 02313ARE | function module-Public Module-M.2 SSD-SATA 6Gb/s-240GB-80.0mm * 22.0mm * 3.58 mm(non-hot-swappable) | EOM |
| 02313ARH | function module-Public Module-M.2 SSD-SATA 6Gb/s-480GB-80.0mm * 22.0mm * 3.58 mm(hot-swappable) | EOM |
| 02313ARJ | function module-Public Module-M.2 SSD-SATA 6Gb/s-480GB-80.0mm * 22.0mm * 3.58 mm(non-hot-swappable) | EOM |
| 90010339 | Liquid Manufactory Auxiliaries,Thermal Grease,X-23-7868-2D,Thermal Conductivity 3.6W/mK / 6.0W/mK,2g,Gap filling thermal conductive for customer use,1ml | Current Engineer replace |
| 03025VYY | Manufactured Board,TaiShan 2280 V2,BC82LCIA,Left Customer Interface,4*2 | Current Engineer replace |
| 02312YJF | Function Module,TaiShan 200 (Model 2280),BC2M5ERISE,Unpacking Inspection Module | Current Engineer replace |
| 43020236 | SAS Expander,NA,VROC KEY,RAID0/1/10,Standard,100mW,0.125MB/s | Current Engineer replace |
| 43020237 | SAS Expander,NA,VROC KEY,RAID 0/1/10/5,Premium,100mW,0.125MB/s | Current Engineer replace |
| 0258Y102 | IO Extended Module-Hard Disk,2288H V7,BC1M02NHBC,Rear 4*2.5" Hard Disk Backplane Module for NVME numa | Current Engineer replace |
| 0258Y047 | IO Extended Module-PCIE,2288H V7,BC1M07PRUB,1*16X SLOT(PCIE5.0)+2*8X SLOT(PCIE4.0)-IO1&2 module,Spare Parts | Current Engineer replace |
| 0258Y046 | IO Extended Module-PCIE,2288H V7,BC1M02PRUE,1*16X SLOT(PCIE4.0)-SLOT2-IO1&2 module,Spare Parts | Current Engineer replace |
| 0258Y013 | IO Extended Module-PCIE,2288H V7,BC1M01PRUC,2*16X SLOT(PCIE5.0)-SLOT1&2-IO1&2 module | Current Engineer replace |
| 0258Y045 | IO Extended Module-PCIE,2288H V7,BC1M02PRUR,2*16X SLOT(PCIE5.0)-SLOT2&3-IO1&2 module for GPU,Spare Parts | Current Engineer replace |
| 0258Y044 | IO Extended Module-PCIE,2288H V7,BC1M02PRUC,2*16X SLOT(PCIE5.0)-SLOT1&2-IO1&2 module,Spare Parts | Current Engineer replace |
| 0258Y010 | IO Extended Module-Hard Disk,2288H V7,BC1M01HBBI,Rear 4*2.5" Hard Disk Backplane Module for HDD | Current Engineer replace |
| 0258Y030 | IO Extended Module-PCIE,2288H V7,BC1M02PRUR,2*16X SLOT(PCIE5.0)-SLOT2&3-IO1&2 module for GPU | Current Engineer replace |
| 0258Y009 | IO Extended Module-Hard Disk,2288H V7,BC1M01NHBC,Rear 4*2.5" Hard Disk Backplane Module for NVME | Current Engineer replace |
| 0258Y007 | IO Extended Module-Hard Disk,2288H V7,BC1M03HBBF,2*3.5" Rear Hard Disk Backplane Module | Current Engineer replace |
| 0258Y006 | IO Extended Module-Hard Disk,2288H V7,BC1M02HBBE,2*2.5" Rear Hard Disk Backplane Module+1*16 Riser card | Current Engineer replace |
| 0258Y017 | IO Extended Module-PCIE,2288H V7,BC1M01PRUF,2*16X SLOT(PCIE4.0)-RISER3 PSU module | Current Engineer replace |
| 0258Y049 | IO Extended Module-Hard Disk,2288H V7,BC1M03HBBE,2*2.5" Rear Hard Disk Backplane Module+1*16 Riser card,Spare Parts | Current Engineer replace |
| 0258Y005 | IO Extended Module-Hard Disk,2288H V7,BC1M01HBBE,2*2.5" Rear Hard Disk Backplane Module | Current Engineer replace |
| 0258Y016 | IO Extended Module-PCIE,2288H V7,BC1M01PRUB,1*16X SLOT(PCIE5.0)+2*8X SLOT(PCIE4.0)-IO1&2 module | Current Engineer replace |
| 0258Y048 | IO Extended Module-PCIE,2288H V7,BC1M02PRUF,2*16X SLOT(PCIE4.0)-IO3 Riser1 module,Spare Parts | Current Engineer replace |
| 0258Y015 | IO Extended Module-PCIE,2288H V7,BC1M01PRUE,1*16X SLOT(PCIE4.0)-SLOT2-Riser1&2 module | Current Engineer replace |
| 02313MJN | Function Module,2288H V5,BC1M01ITMA0,M2 Transform SATA PCIE Riser Moudle(Only Supporting M.2 SATA Disk) | Current Engineer replace |
| 0258Y079 | IO Extended Module-PCIE,2288H V7,BC1M01PRHQ,4GPU chassis second-layer Riser board-IO module | Current Engineer replace |
| 0258Y081 | IO Extended Module-PCIE,2288H V7,BC1M01PRUD,1*16X SLOT(PCIE4.0)-4GPU/rear 10 HDD RISER Module | Current Engineer replace |
| 0258Y264 | IO Extended Module-PCIE,2258 V7,BC1M08PRUB,2*8X SLOT(PCIE4.0)-IO1&2 module | Current Engineer replace |
| 0258Y474 | IO Extended Module-PCIE,2288H V7,BC1M08PRUC,1*16X SLOT(PCIE5.0)-SLOT2&5-IO1&2 module | Current Engineer replace |
| 0258Y193 | IO Extended Module-PCIE,2288H V7,BC1M03PRUC,2*16X SLOT(PCIE5.0)-SLOT1&2-IO1&2 module for full height half length single slot GPU Card | Current Engineer replace |
| 0258Y033 | IO Extended Module-Hard Disk,2288H V7,BC1M02HBBF,2*3.5" Rear Hard Disk Backplane Module for PCH Through | Current Engineer replace |
| 0258Y166 | IO Extended Module-Hard Disk,2288H V7,BC1M06MSMA,Built in M.2 riser card, Supporting SATA/PCIE media,Supports two M.2 media slots | Current Engineer replace |
| 0258Y084 | IO Extended Module-PCIE,2288H V7,BC1M02PRUI,4*8X SLOT(PCIE4.0)-four cards Riser3 Module | Current Engineer replace |
| 0258Y733 | IO Extended Module-Hard Disk,2288H V7,BC1M07HBBS,Rear 4*2.5" Hard Disk Backplane Module for NVMe,PCIE5.0(NUMA dedicated) | Current Engineer replace |
| 0258Y014 | IO Extended Module-PCIE,2288H V7,BC1M01PRUR,2*16X SLOT(PCIE5.0)-SLOT2&3-IO1&2 module | Current Engineer replace |
| 0258Y054 | IO Extended Module-Hard Disk,2288H V7,BC1M04HBBE,2*2.5" Rear Hard Disk Backplane Module+1*16 Riser card for PCH Through | Current Engineer replace |
| 0258Y725 | IO Extended Module-Hard Disk,2288H V7,BC16M03HBBS,Rear 4*2.5" Hard Disk Backplane Module for NVMe,PCIE5.0(non-NUMA dedicated) | Current Engineer replace |
| 0258Y004 | IO Extended Module-Hard Disk,2288H V7,BC1M01HBBG,inner 4*3.5 inch Hard Disk Backplane Module | Current Engineer replace |
| 0258Y089 | IO Extended Module-Hard Disk,2288H V7,BC1M06HBBE,2*2.5" Rear Hard Disk Backplane Module+1*16 Riser card for 25EXP | Current Engineer replace |
| 0258Y088 | IO Extended Module-Hard Disk,2288H V7,BC1M07HBBE,2*2.5" Rear Hard Disk Backplane Module+1*16 Riser card for 12EXP | Current Engineer replace |
| 0258Y161 | IO Extended Module-Hard Disk,2288H V7,BC1M10HBBE,2*2.5" Rear Hard Disk Backplane Module+1*16 Riser card for 25EXP IO2 | Current Engineer replace |
| 0258Y160 | IO Extended Module-Hard Disk,2288H V7,BC1M13HBBE,2*2.5" Rear Hard Disk Backplane Module+1*16 Riser card IO2 | Current Engineer replace |
| 0258Y090 | IO Extended Module-Hard Disk,2288H V7,BC1M03HBBF,2*3.5" Rear Hard Disk Backplane Module for 12EXP | Current Engineer replace |
| 0302Y246 | Manufactured Board,2288H V7,BC15MBSAC,1288H V7/2288H V7 Server Motherboard B,1*1 | Current Field replaceable |
| 0258Y078 | IO Extended Module-PCIE,2288H V7,BC1M02PRUG,4GPU chassis first-layer Riser board-IO module | Current Engineer replace |
| 0258Y077 | IO Extended Module-PCIE,2288H V7,BC1M01PRUP,inner 4 cards second-layer Riser board-IO module | Current Engineer replace |
| 0258Y472 | IO Extended Module-PCIE,2288H V7,BC1M13PRUI,2*8X SLOT(PCIE4.0)-two cards Riser3 Module for Slot9&Slot10 | Current Engineer replace |
| 0258Y076 | IO Extended Module-PCIE,2288H V7,BC1M01PRUO,inner 4 cards first-layer Riser board-IO module | Current Engineer replace |
| 0258Y091 | IO Extended Module-Hard Disk,2288H V7,BC1M02HBBI,IO3 4*2.5" Hard Disk Module for HDD_12EXP Only | Current Engineer replace |
| P/N | Description / Specification | Status |
|---|---|---|
| 04052259 | Power cord,China AC Power 250V2.5A,2.0m,PISM,227IEC53-0.75^2(3C),C5SF,250V,2.5A,Black | Current Engineer replace |
| 04051080 | Power cord,South Africa AC Power 250V10A,3m,PMAM,H05VV-F-1.0mm^2(3C),C13SF,250V,10A,Black | Current Engineer replace |
| 04041119 | Power Cable,Switzerland AC Power Cable 250V10A,3.0m,PJSM ,H05VV-F-1.0mm^2(3C),C13SF,Black | Current Engineer replace |
| 04050517 | Power Cable,China AC Power Cable 250V10A,2.0m,PISM,227IEC53(RVV)1.0mm^2(3C),C13SF,Black | Current Engineer replace |
| 0415G005 | Power cord,China AC Power 250V10A,2.0m,C14SM,227IEC53-1.0^2(3C),C13SF,PDU Cable | Current Engineer replace |
| 0405G02C | Power Cords Cable,China AC Power 250V10A,0.8m,C14SM,227IEC53 1.0^2(3C),C13SF,PDU Cable | Current Engineer replace |
| 0405G02D | Power Cords Cable,Japan AC Power 250V12A,1.8m,C14SM,HVCTF 1.25^2(3C),C13SF,PDU Cable | Current Engineer replace |
| 04050955 | Power Cords Cable,China AC Power,250V10A,1.5m,PISM,227IEC53(RVV)1.0mm^2(3C),C13SF,250V,10A,Black | Current Engineer replace |
| 0405G02F | Power Cords Cable,Australia AC Power 250V10A,1.8m,C14SM,H05VV-F-1.0^2(3C),C13SF,PDU Cable | Current Engineer replace |
| 04041117 | Power Cable,Britain AC Power Cable 250V10A,3.0m,PGAM ,H05VV-F-1.0mm^2(3C),C13AF-L,Black | Current Engineer replace |
| 0405G02H | Power Cords Cable,Korea AC Power 250V10A,1.8m,C14SM,H05VV-F-1.0^2(3C),C13SF,PDU Cable | Current Engineer replace |
| 0405G02K | Power Cords Cable,Denmark AC Power 250V10A,3m,PKSM,H05VV-F-3*1.0^2(3C),C13SF,Black | Current Engineer replace |
| 0405G028 | Power Cords Cable,Korea AC Power 250V10A,3m,PFSM,H05VV-F 3*1.0^2(3C),C13SF,Black | Current Engineer replace |
| 04050588 | Power cord,China AC Power Cable250V10A,1.5 m,C14SM,(227IEC53(RVV)1.0mm^2(3C)),C13SF,250V,10A,White,PDU Cable | Current Engineer replace |
| 0405G029 | Power Cords Cable,North America AC Power 250V10A,1.8m,C14SM,SJT 18AWG(3C),C13SF,PDU Cable | Current Engineer replace |
| 04050784 | Power Cords Cable,China AC Power Cable,250V16A,2m,C14SM,227IEC53-1.0^2(3C),C13SF,Yellow | Current Engineer replace |
| 04051035 | Power cord,India AC Power 250V6A,3m,PM-IIAM,IS 694-1.0^2(3C),C13 SF,250V,6A,Black | Current Engineer replace |
| 04050188 | Power Cords Cable,China AC Power 250V10A,1.5m,C14SM,227IEC53(RVV)1.0mm^2(3C),C13SF,PDU Cable | Current Engineer replace |
| 04020728 | Power Cable,America AC Power Cable,125V10A,3.0m,PBSM,18SJT(3C),C13SF,Black | Current Engineer replace |
| 04042698 | Power Cords Cable,China AC Power 250V10A,15.0m,PISM,227IEC53-1.0^2(3C),C13SF,Black | Current Engineer replace |
| 0415Y021 | Power Cable,0.25m,H2X6(3.0),8*18UL1569B+8*22UL1569B,2*H2X4(4.2),PCIe12-2*PCIe 8 | Current Engineer replace |
| 04042697 | Power Cords Cable,China AC Power 250V10A,10.0m,PISM,227IEC53-1.0^2(3C),C13SF,Black | Current Engineer replace |
| 04042699 | Power Cords Cable,China AC Power 250V10A,20.0m,PISM,227IEC53-1.0^2(3C),C13SF,Black | Current Engineer replace |
| 04041120 | Power Cable,Italy AC Power Cable 250V10A,3.0m,PLSM,H05VV-F-1.0mm^2(3C),C13SF,Black | Current Engineer replace |
| 04047785 | Power Cords Cable,Argentina AC Power 250V10A,3.0m,PISM,H05VV-F-1.0mm^2(3C),C13SF,Black | Current Engineer replace |
| 04051020 | High Speed Cable,Internal Mini SAS HD Cable,0.75m,Internal Mini SAS HD R/A,8*(1P*30AWG+ 2*Drain)+8C*30AWG,Internal Mini SAS HD STR,R/A-STR | Current Engineer replace |
| 04052137 | Power cord,Taiwan AC 125V11A,3.0m,PBSM,HVCTF 3*1.25mm2,C13SF,125V,11A,Black,BSMI | Current Engineer replace |
| 04040888 | Power Cords Cable,Australia AC Power Cable,250V 10A,3.0m,PISM,H05VV-F-1.0mm^2(3C),C13SF,Black | Current Engineer replace |
| 04040889 | Power cord,BS546 250V10A,3.0m,PM-IAM,H05VV-F-1.5mm^2(3C),C13SF,250V,10A,Black | Current Engineer replace |
| 0405G019 | Power Cords Cable,Europe AC 250V10A,1.8m,C14SM,H05VV-F- 3*1.00^2,C13SF,PDU Cable | Current Engineer replace |
| 04050373 | Power cord,China AC Power Cable250V10A,1.0m,C14SM,(227IEC53(RVV)-1.0mm^2(3C)),C13SF,Black,PDU Cable | Current Engineer replace |
| 04041056 | Power cord,Europe AC Power Cable,250V10A,3.0m,PFSM,(H05VVF 1.0^2(3C)),C13SF,250V,10A,BLack | Current Engineer replace |
| 04050139 | Power Cords Cable,China AC Power Cable,250V10A,3m,PISM,227IEC53-1.0^2(3C),C13SF,Black | Current Engineer replace |
| 04150258 | Power Cable,Brazil AC Power Cable 250V10A,3.0m,PNSM ,H05VV-F-1.0mm^2(3C),C13SF,Black | Current Engineer replace |
| 04040887 | Power Cable,Japan AC Power Cable 125V12A,3.0m,PBSM,HVCTF-1.25mm^2(3C),C13SF,Black | Current Engineer replace |
| 14130923 | Optical Cable Parts,MPO/PC,MPO/PC,MULTI-MODE,15m,8 CORES,0m/0m,GJFH-8A1A.2(OM3),3.5MM,LSZH,60mm MPO,Bending insensitive | Current Engineer replace |
| 04050847 | Power cord,China AC Power Cable,250V10A,6.0m,C14SM,(227IEC53-1.0^2(3C)),C13SF,250V,10A,Black,PDU Cable | Current Engineer replace |
| 04051858 | Power cord,China AC Power Cable 250V10A,3.0m,PISM,227IEC53-1.0^2(3C),C13SF,250V,10A,Yellow | Current Engineer replace |
| 04041104 | Power Cords Cable,China AC Power 250V10A,3.0m,PISM,227IEC53-1.0^2(3C),C13SF,Black | Current Engineer replace |
| 04050846 | Power cord,China AC Power Cable,250V10A,3.0m,C14SM,(227IEC53-1.0^2(3C)),C13SF,250V,10A,Black,PDU Cable | Current Engineer replace |
| 04050206 | Power Cable,China AC Power Cable 250V10A,1.0m,PISM,227IEC53(RVV)1.0mm^2(3C),C13SF,Black | Current Engineer replace |
| 04040890 | Power Cable,Britain AC Power Cable 250V10A,3.0m,PGAM ,H05VV-F-1.0mm^2(3C),C13SF,Black | Current Engineer replace |
| 04051021 | High Speed Cable,Internal Mini SAS HD Cable,0.85m,Internal Mini SAS HD R/A,8*(1P*30AWG+ 2*Drain)+8C*30AWG,Internal Mini SAS HD STR,R/A-STR | Current Engineer replace |
| 04051018 | High Speed Cable,Internal Mini SAS HD Cable,0.63m,Internal Mini SAS HD R/A,8*(1P*30AWG+ 2*Drain)+8C*30AWG,Internal Mini SAS HD STR,R/A-STR | Current Engineer replace |
| 0405Y020 | High Speed Cable,HS Cable Slimline-2*mini SAS HD,0.9m&0.8m,Slimline X8 STR,2*((31AWG*1Pair+31AWG*2Drain)*8+31AWG*1Pair*4),2*Internal mini SAS HD R/A,Slimline-2*mini SAS HD | Current Engineer replace |
| 04051403 | High Speed Cable,100G EDR QSFP28 Passive High Speed Cable,1m,QSFP28,CC8P0.4B(S),QSFP28,IB-Mellanox,LSZH | Current Engineer replace |
| 14270054 | BTB Connector module,74,UBC 8X curved,250mm,0.16mm,10mm,3200MB/s,1.57mm,Wire mounting,Y | Current Engineer replace |
| 0405Y011 | High Speed Cable,25G SFP28 Passive High Speed Cable,3m,SFP28,CC2P0.254B(S),SFP28 | Current Engineer replace |
| 0405Y016 | High Speed Cable,High Speed Cable,0.6m,Internal Mini SAS HD RA,8*(1P*30AWG+ 2*Drain)+8C*30AWG,Internal Mini SAS HD RA,RA-RA,0.60m,Internal Mini SAS HD RA,8*(1P*30AWG+ 2*Drain)+8C*30AWG,Internal Mini SAS HD RA,RA-RA | Current Engineer replace |
| 0405Y017 | High Speed Cable,HS Cable Slimline-2*mini SAS HD,0.8m&0.7m,Slimline X8 STR,2*((31AWG*1Pair+31AWG*2Drain)*8+31AWG*1Pair*4),2*Internal mini SAS HD R/A,Slimline-2*mini SAS HD | Current Engineer replace |
| 04051074 | Power cord,India AC Power 250V 16A,3m,PM-IIIAM,IS 694-1.5mm^2(3C),C19SF,250V,16A,Black | Current Engineer replace |
| 0405Y010 | High Speed Cable,25G SFP28 Passive High Speed Cable,1m,SFP28,CC2P0.254B(S),SFP28 | Current Engineer replace |
| 04050422 | Power Cords Cable,China /Europe/America/Korea Multiple Certificate AC Power 250V16A,3.0m,C20SM,H05VV-F-1.5mm^2(3C) +14SJT3(3C),C19SF,PDU Cable | Current Engineer replace |
| 04051079 | Power cord,South Africa AC Power 250V16A,3m,PMAM,H05VV-F-1.5mm^2(3C),C19SF,250V,16A,Black | Current Engineer replace |
| 04152747 | Power Cable,1.8m,HVDC Straight Female,227IEC53(RVV)1.0mm^2(3C),C14SM | Current Engineer replace |
| 04051113 | IT Equipment Cable,Serial Port Cable,3m,D9 FM,CC2P0.32PWG1U,MP8-I | Current Engineer replace |
| 0405Y009 | High Speed Cable,10G Passive SFP+ Cable,5m,(SFP+20M),(CC2P0.4B),(SFP+20M),LSFRZH For Indoor,ETH 10GbE,Y | Current Engineer replace |
| 0405Y008 | High Speed Cable,10G Passive SFP+ Cable,1m,(SFP+20M),(CC2P0.254B),(SFP+20M),LSFRZH For Indoor,ETH 10GbE,LSZH | Current Engineer replace |
| 0405Y128 | Power cord,Japan AC Power 250V15A,3.0m,NEMA5-15PSM,HVCTF-2.0mm^2(3C)black,C19SF,125V,15A | Current Engineer replace |
| 0405Y007 | High Speed Cable,10G SFP+ High Speed Cable,3m,SFP+20M,CC2P0.254B(S),SFP+20M,LSFRZH For Indoor,ETH 10GbE,LSZH | Current Engineer replace |
| 04043396 | Power Cords Cable,China AC Power 250V16A,3.0m,PIAM,227IEC53-2.5^2(3C),C19SF,Black | Current Engineer replace |
| 04052666 | IT Equipment Cable,Signal Cable,0.65m,(H2X25(1.0)),(4*(1P*30AWG+1*Drain)+3* 30AWG Shield+4*(1P*30AWG)+22*UL1571 28AWG),(H2X25(1.0)) | Current Engineer replace |
| 0415Y642 | Power Cable,250V-16A 3m,2.5mm^2(3C),black,C21,2.5mm^2(3C),C20 | Current Engineer replace |
| 04045184 | Power Cords Cable,Australia AC Power 250V16A,3.0m,PISM,H05VVF-2.5^2(3C),C19SF,Black | Current Engineer replace |
| 04051418 | Power cord,China AC Power 250V16A,30.0m,PIAM,227IEC53-2.5^2(3C),C19SF,250V,16A,Black | Current Engineer replace |
| 04080975 | Monitor&Alarm Cable,Signal cable,0.55m,H2X8(2.0),16*UL1685 28AWG,H2X8(2.0),Front HDDboard signal cable-2/4pin sheild | Current Engineer replace |
| 04052139 | Power cord,Taiwan AC 125V15A,3.0m,PBSM,VCTFK3*2.0mm2(3C),C19SF,125V,15A,Black,BSMI | Current Engineer replace |
| 04050189 | Power Cords Cable,China AC Power 250V 16A,1.0m,C20SM,227IEC53x1.5^2(3C),C19SF,PDU Cable | Current Engineer replace |
| 04044598 | Power Cords Cable,Europe AC Power 250V16A,3.0m,PFAM,H05VVF-1.5^2(3C),C19SF,Black | Current Engineer replace |
| 04044597 | Power cord,BS546 250V16A,3.0m,PM-IAM,H05VV-F-1.5mm^2(3C),C19SF,250V,16A,Black | Current Engineer replace |
| 04050850 | Power Cords Cable,Britain AC Power Cable,250V13A,3.0m,PG AM,H05VV-F-1.5mm^2(3C),C19 SF,Black | Current Engineer replace |
| 04151188 | Power Cable,1.5m,HVDC Straight Female,227IEC53(RVV)1.0mm^2(3C) | Current Engineer replace |
| 04050856 | Power Cords Cable,Australia AC Power 250V16A,3.0m,C20SM,H05VV-F-1.5^2(3C),C19SF,PDU Power Cord | Current Engineer replace |
| 04150259 | Power Cords Cable,Brazil AC Power 250V16A,3.0m,PN-ISM ,H05VVF-1.5^2(3C),C19SF,Black | Current Engineer replace |
| 04050855 | Power Cords Cable,Japan AC Power 250V15A,3.0m,C20SM,VCTF-2.0^2(3C),C19SF,PDU Power Cord | Current Engineer replace |
| 04044603 | Power Cords Cable,North America AC Power 125V20A,3.0m,NEMA5-20PAM,12SJT(3C),C19SF,Black | Current Engineer replace |
| 04080980 | Monitor&Alarm Cable,Signal cable,0.2m,H2X9(2.0),14*28UL1685B/14*28UL1685B(S),H2X9(2.0) | Current Engineer replace |
| 04051322 | Power cord,Switzerland AC Power Cable,3m,PJ-II SM,H05VV-F-1.5mm^2(3C),C19SF,250V,16A | Current Engineer replace |
| 0405Y023 | High Speed Cable,HS Cable Slimline-2*mini SAS HD,0.65m&0.2m&0.35m,Slimline X8 STR,2*((31AWG*1Pair+31AWG*2Drain)*8+31AWG*1Pair*4),Internal mini SAS HD R/A+Internal mini SAS HD STR,Slimline-3*Mini SAS HD | Current Engineer replace |
| 0405Y026 | High Speed Cable,HS Cable Slimline-Mini SAS HD,0.4m,Slimline X8 STR,2*((31AWG*1Pair+31AWG*2Drain)*8+31AWG*1Pair*4),Internal mini SAS HD STR,Slimline-Mini SAS HD | Current Engineer replace |
| 0405Y028 | High Speed Cable,HS Cable Slimline-2*mini SAS HD,0.8m&0.7m,Slimline X8 R/A,2*((31AWG*1Pair+31AWG*2Drain)*8+31AWG*1Pair*4),2*Internal mini SAS HD R/A,Slimline-2*mini SAS HD | Current Engineer replace |
| 04044600 | Power cord,Japan AC Power Cable,3.0m,NEMA5-20PAM,HVCTF-3.5mm^2(3C),C19SF,125V,20A,Black | Current Engineer replace |
| 0415Y075 | Power Cable,0.20m,Black,H2X6(3.0),8*18UL1569B,H2X4(4.2),PCIE 12Pin-PCIE 8Pin | Current Engineer replace |
| 14270058 | BTB Connector module,184pin-74pin*2,UBCDD 16X vertical plug,UBC 8X right-angle plug*2,0.6&0.65m,0.16mm,10mm,32000MB/s,1.57mm,Wire mounting,Y | Current Engineer replace |
| 0405Y021 | High Speed Cable,HS Cable Slimline-2*mini SAS HD,0.85m&0.75m,Slimline X8 STR,2*((31AWG*1Pair+31AWG*2Drain)*8+31AWG*1Pair*4),2*Internal mini SAS HD R/A,Slimline-2*mini SAS HD | Current Engineer replace |
| 0405Y019 | High Speed Cable,HS Cable Slimline-2*mini SAS HD,1.0m&0.9m,Slimline X8 STR,2*((31AWG*1Pair+31AWG*2Drain)*8+31AWG*1Pair*4),2*Internal mini SAS HD R/A,Slimline-2*mini SAS HD | Current Engineer replace |
| 04150441 | Power Cable,3.5m,4mm^2,2*T4^2GY,H07Z-K-4^2BL+H07Z-K-4^2B,2*T4^2GY,LSZH | Current Engineer replace |
| 04152464 | Power Cable,0.5m,4mm^2,(OT6-4),(H07Z-K-4^2G&Y),(OT6-6),LSZH,YES | Current Engineer replace |
| 04080974 | Monitor&Alarm Cable,Signal cable,0.45m,H2X6(2.0),12*UL1685 28AWG,H2X6(2.0),Fan board signal cable-2/4pin sheild | Current Engineer replace |
| 14270055 | BTB Connector module,74,UBC 8X curved,150mm,0.16mm,10mm,32000MB/s,1.57mm,Wire mounting,Y | Current Engineer replace |
| 0415Y029 | Power Cable,0.65m&0.63m,2*6.0mm^2,red/black,80A R/A easy connector,10UL1015RE+10UL1015BL,2*OT6-4 | Current Engineer replace |
| 04153757 | Power Cable,0.52m,black,80A R/A easy connector,5*18UL2651,80A R/A easy connector | Current Engineer replace |
| 0415Y125 | Power Cable,0.25m,Black,H2X6(3.0),12*18UL1569B/1*28UL1685B,(H2X6(3.0)/1X4(2.0)) | Current Engineer replace |
| 1427Y148 | BTB Connector module,74,UBC 8X curved,900mm,0.16mm,10mm,22500MB/s,1.57mm,Wire mounting,Y | Current Engineer replace |
| 1427Y149 | BTB Connector module,74,Slimline 8X vertical,950&900mm,0.16mm,10mm,22500MB/s,1.57mm,Wire mounting,Y | Current Engineer replace |
| 04052385 | High Speed Cable,Mini SAS HD 4i High Speed Cable,0.2m&0.35m,Internal Mini SAS HD STR,8*(1P*30AWG+ 2*Drain)+8C*30AWG,2*Internal Mini SAS HD STR,SAS HD To 2*SAS HD | Current Engineer replace |
| 0415Y210 | Power Cable,0.50m&0.62m,Black,80A R/A easy connector,20*18UL2651B,2*80A STR easy connector,Parallel | Current Engineer replace |
| 04153776 | Power Cable,0.25m,H2X6(3.0),18UL2651(8C)B(Flat),H2X4(4.2) | Current Engineer replace |
| 04153775 | Power Cable,0.60m,black,80A STR easy connector,5*18UL2651,80A R/A easy connector | Current Engineer replace |
| 1427Y293 | BTB Connector module,74,UBC 8X curved*4,0.33&0.4&0.45&0.52m,0.16mm,10mm,32000MB/s,1.57mm,Wire mounting,Y | Current Engineer replace |
| 1427Y138 | BTB Connector module,74,UBC 8X curved,250mm,0.16mm,10mm,32000MB/s,1.57mm,Wire mounting,Y | Current Engineer replace |
| 1427Y139 | BTB Connector module,74,UBC 8X curved,300mm,0.16mm,10mm,32000MB/s,1.57mm,Wire mounting,Y | Current Engineer replace |
| 1427Y140 | BTB Connector module,74,UBC 8X curved,400mm,0.16mm,10mm,32000MB/s,1.57mm,Wire mounting,Y | Current Engineer replace |
| 1427Y141 | BTB Connector module,74,UBC 8X curved,450mm,0.16mm,10mm,32000MB/s,1.57mm,Wire mounting,Y | Current Engineer replace |
| P/N | Description / Specification | Status |
|---|---|---|
| 0231Y192 | Function Module,2288H V7,BC1M23FAN,8080+ Fan module | Current Field replaceable |
| 0231Y191 | Function Module,2288H V7,BC1M22FAN,8038+ Fan module | Current Field replaceable |
Operating System Compatibility
| Operating System | Version / Kernel | Release |
|---|---|---|
| Asianux Server 8.8 | 5.10.134-16.2.axs8.x86_64 | Asianux Server 8.8 for Intel EM64T |
| BC-Linux V8.4 | 5.10.84-310.5.el8.bclinux.x86_64 | BigClould Enterprise Linux 8.4 |
| BC-Linux V8.6 | 5.10.134-12.2.el8.bclinux.x86_64 | BigClould Enterprise Linux 8.6 |
| Citrix Hypervisor 8.2 | 4.19.0+1 | Citrix Hypervisor 8.2 LTSR |
| Debian 12.0 | 6.1.0-9-amd64 | Debian 12.0 for Intel EM64T |
| Debian 12.5 | 6.1.0-18-amd64 | Debian 12.5 for Intel EM64T |
| FusionOS 23 | 5.10.0-136.23.0.99.u37.fos23.x86_64 | FusionOS 23 |
| Kylin Linux Advanced Server V10 SP3 2403 | 4.19.90-89.11.v2401.ky10.x86_64 | Kylin Linux Advanced Server V10 SP3 2403 for Intel EM64T |
| Kylin Linux Advanced Server V11 2503 | 6.6.0-32.7.v2505.ky11.x86_64 | Kylin Linux Advanced Server V11 2503 for Intel EM64T |
| Oracle Linux 8.10 | 5.15.0-206.153.7.1.el8uek.x86_64 | Oracle Linux Release 8 Update 10 for Intel EM64T |
| Oracle Linux 8.6 | 5.4.17-2136.307.3.1.el8uek.x86_64 | Oracle Linux Release 8 Update 6 for Intel EM64T |
| Oracle Linux 8.7 | 5.15.0-3.60.5.1.el8uek.x86_64 | Oracle Linux Release 8 Update 7 for Intel EM64T |
| Oracle Linux 8.8 | 5.15.0-101.103.2.1.el8uek.x86_64 | Oracle Linux Release 8 Update 8 for Intel EM64T |
| Oracle Linux 8.9 | 5.15.0-200.131.27.el8uek.x86_64 | Oracle Linux Release 8 Update 9 for Intel EM64T |
| Oracle Linux 9.0 | 5.15.0-0.30.19.el9uek.x86_64 | Oracle Linux Release 9 for Intel EM64T |
| Oracle Linux 9.1 | 5.15.0-3.60.5.1.el9uek.x86_64 | Oracle Linux Release 9 Update 1 for Intel EM64T |
| Oracle Linux 9.2 | 5.15.0-101.103.2.1.el9uek.x86_64 | Oracle Linux Release 9 Update 2 for Intel EM64T |
| Oracle Linux 9.3 | 5.15.0-200.131.27.el9uek.x86_64 | Oracle Linux Release 9 Update 3 for Intel EM64T |
| Oracle Linux 9.4 | 5.15.0-205.149.5.1.el9uek.x86_64 | Oracle Linux Release 9 Update 4 for Intel EM64T |
| Oracle Linux 9.5 | 5.15.0-302.167.6.el9uek.x86_64 | Oracle Linux Release 9 Update 5 for Intel EM64T |
| RHEL 10.0 | 6.12.0-55.9.1.el10_0.x86_64 | Red Hat Enterprise Linux 10 Server for Intel EM64T |
| RHEL 10.1 | 6.12.0-124.8.1.el10_1.x86_64 | Red Hat Enterprise Linux 10 Update 1 Server for Intel EM64T |
| RHEL 10.2 | 6.12.0-211.7.3.el10_2.x86_64 | Red Hat Enterprise Linux 10 Update 2 Server for Intel EM64T |
| RHEL 8.10 | 4.18.0-553.el8_10.x86_64 | Red Hat Enterprise Linux 8 Update 10 Server for Intel EM64T |
| RHEL 8.6 | 4.18.0-372.9.1.el8.x86_64 | Red Hat Enterprise Linux 8 Update 6 Server for Intel EM64T |
| RHEL 8.6 KVM | 4.18.0-372.9.1.el8.x86_64 | Red Hat Enterprise Linux 8 Update 6 Server for Intel EM64T |
| RHEL 8.7 | 4.18.0-425.3.1.el8.x86_64 | Red Hat Enterprise Linux 8 Update 7 Server for Intel EM64T |
| RHEL 8.7 KVM | 4.18.0-425.3.1.el8.x86_64 | Red Hat Enterprise Linux 8 Update 7 Server for Intel EM64T |
| RHEL 8.8 | 4.18.0-477.10.1.el8_8.x86_64 | Red Hat Enterprise Linux 8 Update 8 Server for Intel EM64T |
| RHEL 8.9 | 4.18.0-513.5.1.el8_9.x86_64 | Red Hat Enterprise Linux 8 Update 9 Server for Intel EM64T |
| RHEL 9.0 | 5.14.0-70.13.1.el9_0.x86_64 | Red Hat Enterprise Linux 9 Server for Intel EM64T |
| RHEL 9.0 KVM | 5.14.0-70.13.1.el9_0.x86_64 | Red Hat Enterprise Linux 9 Server for Intel EM64T |
| RHEL 9.1 | 5.14.0-162.6.1.el9_1.x86_64 | Red Hat Enterprise Linux 9 Update 1 Server for Intel EM64T |
| RHEL 9.1 KVM | 5.14.0-162.6.1.el9_1.x86_64 | Red Hat Enterprise Linux 9 Update 1 Server for Intel EM64T |
| RHEL 9.2 | 5.14.0-284.11.1.el9_2.x86_64 | Red Hat Enterprise Linux 9 Update 2 Server for Intel EM64T |
| RHEL 9.3 | 5.14.0-362.8.1.el9_3.x86_64 | Red Hat Enterprise Linux 9 Update 3 Server for Intel EM64T |
| RHEL 9.4 | 5.14.0-427.13.1.el9_4.x86_64 | Red Hat Enterprise Linux 9 Update 4 Server for Intel EM64T |
| RHEL 9.5 | 5.14.0-503.11.1.el9_5.x86_64 | Red Hat Enterprise Linux 9 Update 5 Server for Intel EM64T |
| RHEL 9.6 | 5.14.0-570.12.1.el9_6.x86_64 | Red Hat Enterprise Linux 9 Update 6 Server for Intel EM64T |
| RHEL 9.7 | 5.14.0-611.5.1.el9_7.x86_64 | Red Hat Enterprise Linux 9 Update 7 Server for Intel EM64T |
| RHEL 9.8 | 5.14.0-687.5.3.el9_8.x86_64 | Red Hat Enterprise Linux 9 Update 8 Server for Intel EM64T |
| Rocky Linux 10.0 | 6.12.0-55.12.1.el10_0.x86_64 | Rocky Linux 10 Server for Intel EM64T |
| Rocky Linux 10.1 | 6.12.0-124.8.1.el10_1.x86_64 | Rocky Linux 10 Update 1 Server for Intel EM64T |
| Rocky Linux 10.2 | 6.12.0-211.16.1.el10_2.0.1.x86_64 | Rocky Linux 10 Update 2 Server for Intel EM64T |
| Rocky Linux 8.10 | 4.18.0-553.el8_10.x86_64 | Rocky Linux 8 Update 10 Server for Intel EM64T |
| Rocky Linux 8.6 | 4.18.0-372.9.1.el8.x86_64 | Rocky Linux 8 Update 6 Server for Intel EM64T |
| Rocky Linux 8.7 | 4.18.0-425.3.1.el8.x86_64 | Rocky Linux 8 Update 7 Server for Intel EM64T |
| Rocky Linux 8.8 | 4.18.0-477.10.1.el8_8.x86_64 | Rocky Linux 8 Update 8 Server for Intel EM64T |
| Rocky Linux 8.9 | 4.18.0-513.5.1.el8_9.x86_64 | Rocky Linux 8 Update 9 Server for Intel EM64T |
| Rocky Linux 9.0 | 5.14.0-70.13.1.el9_0.x86_64 | Rocky Linux 9 Server for Intel EM64T |
| Rocky Linux 9.1 | 5.14.0-162.6.1.el9_1.x86_64 | Rocky Linux 9 Update 1 Server for Intel EM64T |
| Rocky Linux 9.2 | 5.14.0-284.11.1.el9_2.x86_64 | Rocky Linux 9 Update 2 Server for Intel EM64T |
| Rocky Linux 9.3 | 5.14.0-362.8.1.el9_3.x86_64 | Rocky Linux 9 Update 3 Server for Intel EM64T |
| Rocky Linux 9.4 | 5.14.0-427.13.1.el9_4.x86_64 | Rocky Linux 9 Update 4 Server for Intel EM64T |
| Rocky Linux 9.5 | 5.14.0-503.14.1.el9_5.x86_64 | Rocky Linux 9 Update 5 Server for Intel EM64T |
| Rocky Linux 9.6 | 5.14.0-570.17.1.el9_6.x86_64 | Rocky Linux 9 Update 6 Server for Intel EM64T |
| Rocky Linux 9.7 | 5.14.0-611.5.1.el9_7.x86_64 | Rocky Linux 9 Update 7 Server for Intel EM64T |
| Rocky Linux 9.8 | 5.14.0-687.10.1.el9_8.0.1.x86_64 | Rocky Linux 9 Update 8 Server for Intel EM64T |
| SLES 15 SP4 | 5.14.21-150400.22-default | SUSE Linux Enterprise Server 15 Service Pack 4 for AMD64 & Intel64 |
| SLES 15 SP5 | 5.14.21-150500.53-default | SUSE Linux Enterprise Server 15 Service Pack 5 for AMD64 & Intel64 |
| SLES 15 SP6 | 6.4.0-150600.21-default | SUSE Linux Enterprise Server 15 Service Pack 6 for AMD64 & Intel64 |
| SLES 15 SP7 | 6.4.0-150700.51-default | SUSE Linux Enterprise Server 15 Service Pack 7 for AMD64 & Intel64 |
| SLES 16 | 6.12.0-160000.5-default | SUSE Linux Enterprise Server 16 for AMD64 & Intel64 |
| Ubuntu 22.04 LTS | 5.15.0-25-generic | Ubuntu 22.04 LTS Server Edition for Intel EM64T |
| Ubuntu 22.04.1 LTS | 5.15.0-43-generic | Ubuntu 22.04.1 LTS Server Edition for Intel EM64T |
| Ubuntu 22.04.2 LTS | 5.15.0-60-generic | Ubuntu 22.04.2 LTS Server Edition for Intel EM64T |
| Ubuntu 22.04.3 LTS | 5.15.0-78-generic | Ubuntu 22.04.3 LTS Server Edition for Intel EM64T |
| Ubuntu 22.04.5 LTS | 5.15.0-119-generic | Ubuntu 22.04.5 LTS Server Edition for Intel EM64T |
| Ubuntu 24.04 LTS | 6.8.0-31-generic | Ubuntu 24.04 LTS Server Edition for Intel EM64T |
| Ubuntu 24.04.1 LTS | 6.8.0-41-generic | Ubuntu 24.04.1 LTS Server Edition for Intel EM64T |
| Ubuntu 24.04.2 LTS | 6.8.0-53-generic | Ubuntu 24.04.2 LTS Server Edition for Intel EM64T |
| Ubuntu 24.04.3 LTS | 6.8.0-71-generic | Ubuntu 24.04.3 LTS Server Edition for Intel EM64T |
| Ubuntu 26.04 LTS | 7.0.0-14-generic | Ubuntu 26.04 LTS Server Edition for Intel EM64T |
| VMware ESXi 7.0 U3 | build-18644231 | VMware ESXi 7.0 Update 3 for Intel EM64T |
| VMware ESXi 8.0 | build-20513097 | VMware ESXi 8.0 for Intel EM64T |
| VMware ESXi 8.0 U1 | build-21495797 | VMware ESXi 8.0 Update 1 for Intel EM64T |
| VMware ESXi 8.0 U2 | build-22380479 | VMware ESXi 8.0 Update 2 for Intel EM64T |
| VMware ESXi 8.0 U3 | build-24022510 | VMware ESXi 8.0 Update 3 for Intel EM64T |
| VMware ESXi 9.0 | build-24755229 | VMware ESXi 9.0 for Intel EM64T |
| VMware ESXi 9.1 | build-25370933 | VMware ESXi 9.1 for Intel EM64T |
| Windows Server 2019 | Build 17763 | Microsoft Windows Server 2019 x64 |
| Windows Server 2019 Hyper-V | Build 17763 | Microsoft Windows Server 2019 Hyper-V x64 |
| Windows Server 2022 | Build 20348 | Microsoft Windows Server 2022 x64 |
| Windows Server 2022 Hyper-V | Build 20348 | Microsoft Windows Server 2022 Hyper-V x64 |
| Windows Server 2025 | Build 26100 | Microsoft Windows Server 2025 x64 |
| openEuler 22.03 LTS SP1 | 5.10.0-136.12.0.86.oe2203sp1.x86_64 | openEuler 22.03 LTS SP1 (powered by openEuler) |
| openEuler 22.03 LTS SP2 | 5.10.0-153.12.0.92.oe2203sp2.x86_64 | openEuler 22.03 LTS SP2 (powered by openEuler) |
| openEuler 22.03 LTS SP3 | 5.10.0-182.0.0.95.oe2203sp3.x86_64 | openEuler 22.03 LTS SP3 (powered by openEuler) |
| openEuler 24.03 LTS | 6.6.0-28.0.0.34.oe2403.x86_64 | openEuler 24.03 LTS (powered by openEuler) |
| openEuler 24.03 LTS SP1 | 6.6.0-72.0.0.76.oe2403sp1.x86_64 | openEuler 24.03 LTS SP1 (powered by openEuler) |
| openEuler 24.03 LTS SP2 | 6.6.0-98.0.0.103.oe2403sp2.x86_64 | openEuler 24.03 LTS SP2 (power by openEuler) |
Configuring, expanding or replacing this server? Send us your part list or BOM for a fast quotation.
Request a QuoteSelecting components for the 2288H V7
These points from the matrix matter when configuring or expanding a unit:
- Choose the processor to the workload. Validated options include from the Bronze 3408U to high-end options such as the Silver 4516Y, with up to 64 cores per socket.
- Memory: DDR5 RDIMMs from 16GB to 256GB at up to 6400 MT/s. Give us your capacity target and we will confirm the supported DIMM population and channel rules.
- RAID levels follow the controller. The validated controllers support RAID 0, 1, 5, 6, 10, 50, 60, JBOD. Cacheless entry cards suit boot and mirroring; cached cards with a supercapacitor enable parity RAID for data arrays; JBOD/IT cards provide passthrough to software RAID.
- Storage mix. Validated options include SAS/SATA drives up to 30 TB and PCIe NVMe SSDs up to 8 TB. Backplane and tray variants are listed separately under Drive Backplanes.
- Networking from 100GbE to 25GbE. OCP 3.0 and PCIe adapters are validated for the listed speeds; some SKUs include optical modules and others do not, so check the part description.
- Power: 900–3000W supplies. Platinum and titanium-rated AC units are listed, with redundant pairs for high availability; confirm the rating your GPU and drive population require.
Reference workload profiles
These profiles show how validated components combine; each is configured and quoted to order.
- Virtualization / private cloud: balanced processors, a large RDIMM footprint, hardware RAID with cache and redundant power.
- Database / in-memory: high-frequency processors, maximum memory, PCIe NVMe for log and hot data.
- All-flash node: parity-capable RAID or HBA, a full set of NVMe SSDs, high-wattage titanium PSU.
- Storage / backup node: cached RAID or JBOD passthrough, a full set of high-capacity drives, high-wattage PSU.
- General application / infra: mid-bin processors, moderate memory and storage, cost-effective networking.
The 2288H V7 in the FusionServer range
The numbered FusionServer generations make it straightforward to choose between current and supported hardware. The 2288H V7 is a V7 platform: 4th/5th Generation Intel Xeon Scalable, DDR5, PCIe 4.0/5.0.
Earlier supported generations remain useful:
- V6: 3rd Generation Intel Xeon Scalable, DDR4, PCIe 4.0 — supported, cost-effective for standardised or budget projects.
- V5: 1st/2nd Generation Intel Xeon Scalable, DDR4, PCIe 3.0 — supported, cost-effective for standardised or budget projects.
We supply new systems with manufacturer warranty and can source validated parts for earlier generations when a budget, software-licensing or support window calls for them. Ask us which generation fits.
2288H V7 — compatibility FAQ
Which processors does the 2288H V7 support?
The matrix lists from the Bronze 3408U to high-end options such as the Silver 4516Y, with up to 64 cores per socket. Confirm the thermal and power envelope for your chassis and PSU before ordering.
What memory can I install?
Validated DDR5 RDIMMs range from 16GB to 256GB at up to 6400 MT/s. Tell us your capacity target and we will confirm the supported DIMM population.
Which RAID levels are supported?
Validated controllers support RAID 0, 1, 5, 6, 10, 50, 60, JBOD. Choose a cached card with a supercapacitor for parity RAID (5/6/50/60), an entry card for 0/1/10, or an IT/JBOD card for software RAID passthrough.
What drives are validated?
The matrix lists SAS/SATA drives up to 30 TB and NVMe SSDs up to 8 TB. See the Hard Drives and NVMe tabs for the full list, form factors and current status.
What network speeds are supported?
Validated OCP and PCIe adapters cover 100GbE, 10GbE, 200GbE, 25GbE. Note whether a SKU includes optical modules; we can supply matched optics if required.
What power supplies are available?
The list runs from 900W to 3000W in platinum and titanium ratings. Redundant pairs can be configured for high availability; size the PSU to your CPU, GPU and drive load.
Which operating systems are certified?
The OS matrix lists 91 certified builds, including Red Hat Enterprise Linux, Rocky Linux, SUSE Linux Enterprise Server, Ubuntu, VMware ESXi, Windows Server, each with its exact kernel or build string. Additional builds can often be confirmed on request.
What do the lifecycle statuses mean?
Current/GA parts are in production; PILOT and DEVELOP parts are under limited rollout or qualification; EOM parts are out of marketing but supported as spares. Prefer Current parts for new builds.
Can you supply the server or just parts?
Both. We configure complete systems and supply every validated component listed here with warranty. Send a part list or BOM for a fast quotation.
serverbastion.com