Call: +86 18001060290    E-mail: info@sell-server.com

FusionServer 2488H V5 Compatibility

FusionServer 2488H V5 Compatibility

The FusionServer Pro 2488H V5 is 2U high-performance dual-socket server. It is a 2U platform tuned for high performance and large memory of this xFusion generation, designed for high-performance databases and in-memory workloads. The platform runs on 1st/2nd Generation Intel Xeon Scalable with DDR4 memory and PCIe 3.0 expansion.

Below is the verified compatibility matrix for this model: 544 validated line items across 10 component categories and 166 certified operating-system builds, taken from xFusion’s official compatibility data and presented in English. Every part number listed is published by xFusion for this chassis; nothing is guessed or cross-filled from other models.

Form factor2u high-performance dual-socket
Processor rangeGold 5115 – Platinum 8280M
Top core countUp to 28 cores / socket
Memory modulesDDR4 8–512GB
Memory speedUp to 3200 MT/s
Largest drive15 TB
NVMe capacityUp to 8 TB
Network speeds100GbE/10GbE/25GbE
Power supplies900–2000W
Validated544 parts · 166 OS

Compatibility matrix

Browse validated parts by category using the tabs below. Each tab shows its item count; search inside a tab by part number or keyword, and expand the full list. Parts marked Current are actively orderable; life-cycle parts are still supported and often available as spares. The OS table lists the exact certified kernel or build.

P/NDescription / SpecificationStatus
41020622X86 series-FCLGA3647-2500MHz-1.6V/1.83V-64bit-205000mW-Skylake-SP Xeon Platinum 8180-28Core-IT product-line dedicated EOP
41020623X86 series-FCLGA3647-2000MHz-1.6V/1.83V-64bit-125000mW-Skylake SP Xeon Gold 6138T-20Core EOP
41020624X86 series-FCLGA3647-2100MHz-1.6V/1.83V-64bit-125000mW-Skylake SP Xeon Gold 6130T-16Core EOP
41020643X86 series-FCLGA3647-2200MHz-1.6V/1.83V-64bit-105000mW-Skylake SP Xeon Gold 5120T-14Core EOP
41020650X86 series-FCLGA3647-2100MHz-1.6V/1.83V-64bit-165000mW-Skylake-SP Xeon Platinum 8176-28Core-IT product-line dedicated EOP
41020652X86 series-FCLGA3647-2100MHz-1.6V/1.83V-64bit-165000mW-Skylake-SP Xeon Platinum 8170-26Core-IT product-line dedicated EOP
41020653X86 series-FCLGA3647-2700MHz-1.6V/1.83V-64bit-205000mW-Skylake-SP Xeon Platinum 8168-24Core-IT product-line dedicated EOP
41020654X86 series-FCLGA3647-2000MHz-1.6V/1.83V-64bit-150000mW-Skylake-SP Xeon Platinum 8164-26Core-IT product-line dedicated EOP
41020655X86 series-FCLGA3647-2100MHz-1.6V/1.83V-64bit-150000mW-Skylake-SP Xeon Platinum 8160-24Core-IT product-line dedicated EOP
41020656X86 series-FCLGA3647-3000MHz-1.6V/1.83V-64bit-150000mW-Skylake-SP Xeon Platinum 8158-12Core-IT product-line dedicated EOP
41020657X86 series-FCLGA3647-3600MHz-1.6V/1.83V-64bit-105000mW-Skylake-SP Xeon Platinum 8156-4Core-IT product-line dedicated EOP
41020658X86 series-FCLGA3647-2000MHz-1.6V/1.83V-64bit-125000mW-Skylake-SP Xeon Platinum 8153-16Core-IT product-line dedicated EOP
41020659X86 series-FCLGA3647-3000MHz-1.6V/1.83V-64bit-200000mW-Skylake-SP Xeon Gold 6154-18Core-IT product-line dedicated EOP
41020660X86 series-FCLGA3647-2100MHz-1.6V/1.83V-64bit-140000mW-Skylake-SP Xeon Gold 6152-22Core-IT product-line dedicated EOP
41020661X86 series-FCLGA3647-2700MHz-1.6V/1.83V-64bit-165000mW-Skylake-SP Xeon Gold 6150-18Core-IT product-line dedicated EOP
41020662X86 series-FCLGA3647-2400MHz-1.6V/1.83V-64bit-150000mW-Skylake-SP Xeon Gold 6148-20Core-IT product-line dedicated EOP
41020663X86 series-FCLGA3647-2600MHz-1.6V/1.83V-64bit-150000mW-Skylake-SP Xeon Gold 6142-16Core-IT product-line dedicated EOP
41020664X86 series-FCLGA3647-2300MHz-1.6V/1.83V-64bit-140000mW-Skylake-SP Xeon Gold 6140-18Core-IT product-line dedicated EOP
41020665X86 series-FCLGA3647-2000MHz-1.6V/1.83V-64bit-125000mW-Skylake-SP Xeon Gold 6138-20Core-IT product-line dedicated EOP
41020666X86 series-FCLGA3647-3000MHz-1.6V/1.83V-64bit-150000mW-Skylake-SP Xeon Gold 6136-12Core-IT product-line dedicated EOP
41020667X86 series-FCLGA3647-3200MHz-1.6V/1.83V-64bit-130000mW-Skylake-SP Xeon Gold 6134-8Core-IT product-line dedicated EOP
41020668X86 series-FCLGA3647-2600MHz-1.6V/1.83V-64bit-140000mW-Skylake-SP Xeon Gold 6132-14Core-IT product-line dedicated EOP
41020669X86 series-FCLGA3647-2100MHz-1.6V/1.83V-64bit-125000mW-Skylake-SP Xeon Gold 6130-16Core-IT product-line dedicated EOP
41020670X86 series-FCLGA3647-3400MHz-1.6V/1.83V-64bit-115000mW-Skylake-SP Xeon Gold 6128-6Core-IT product-line dedicated EOP
41020671X86 series-FCLGA3647-2600MHz-1.6V/1.83V-64bit-125000mW-Skylake-SP Xeon Gold 6126-12Core-IT product-line dedicated EOP
41020672X86 series-FCLGA3647-3600MHz-1.6V/1.83V-64bit-105000mW-Skylake-SP Xeon Gold 5122-4Core-IT product-line dedicated EOP
41020673X86 series-FCLGA3647-2200MHz-1.6V/1.83V-64bit-105000mW-Skylake-SP Xeon Gold 5120-14Core-IT product-line dedicated EOP
41020674X86 series-FCLGA3647-2300MHz-1.6V/1.83V-64bit-105000mW-Skylake-SP Xeon Gold 5118-12Core-IT product-line dedicated EOP
41020675X86 series-FCLGA3647-2400MHz-1.6V/1.83V-64bit-85000mW-Skylake-SP Xeon Gold 5115-10Core-IT product-line dedicated EOP
41020690X86 series-FCLGA3647-3200MHz-1.6V/1.83V-64bit-165000mW-Skylake-SP Xeon Gold 6146-12Core-IT product-line dedicated EOP
41020691X86 series-FCLGA3647-3500MHz-1.6V/1.83V-64bit-150000mW-Skylake-SP Xeon Gold 6144-8Core-IT product-line dedicated EOP
41020696X86 series-FCLGA3647-2500MHz-1.6V/1.83V-64bit-205000mW-Skylake-SP Xeon Platinum 8180M-28Core-IT product-line dedicated EOP
41020697X86 series-FCLGA3647-2100MHz-1.6V/1.83V-64bit-165000mW-Skylake-SP Xeon Platinum 8176M-28Core-IT product-line dedicated EOS
41020698X86 series-FCLGA3647-2100MHz-1.6V/1.83V-64bit-165000mW-Skylake-SP Xeon Platinum 8170M-26Core-IT product-line dedicated EOS
41020699X86 series-FCLGA3647-2100MHz-1.6V/1.83V-64bit-150000mW-Skylake-SP Xeon Platinum 8160M-24Core-IT product-line dedicated EOP
41020700X86 series-FCLGA3647-2600MHz-1.6V/1.83V-64bit-150000mW-Skylake-SP Xeon Gold 6142M-16Core-IT product-line dedicated EOP
41020701X86 series-FCLGA3647-2300MHz-1.6V/1.83V-64bit-140000mW-Skylake-SP Xeon Gold 6140M-18Core-IT product-line dedicated EOP
41020702X86 series-FCLGA3647-3200MHz-1.6V/1.83V-64bit-130000mW-Skylake-SP Xeon Gold 6134M-8Core-IT product-line dedicated EOP
41020743X86 series-FCLGA3647-2700MHz-1.6V/1.83V-64bit-205000mW-Cascade lake-SP Xeon Platinum 8280-28Core-IT product-line dedicated EOP
41020779X86 series-FCLGA3647-2700MHz-1.6V/1.83V-64bit-205000mW-Cascade lake-SP Xeon Platinum 8280M-28Core-IT product-line dedicated EOP
41020780X86 series-FCLGA3647-2700MHz-1.6V/1.83V-64bit-205000mW-Cascade lake-SP Xeon Platinum 8280L-28Core-IT product-line dedicated EOP
41020781X86 series-FCLGA3647-2200MHz-1.6V/1.83V-64bit-165000mW-Cascade lake-SP Xeon Platinum 8276-28Core-IT product-line dedicated EOP
41020782X86 series-FCLGA3647-2200MHz-1.6V/1.83V-64bit-165000mW-Cascade lake-SP Xeon Platinum 8276M-28Core-IT product-line dedicated EOP
41020783X86 series-FCLGA3647-2200MHz-1.6V/1.83V-64bit-165000mW-Cascade lake-SP Xeon Platinum 8276L-28Core-IT product-line dedicated EOP
41020784X86 series-FCLGA3647-2700MHz-1.6V/1.83V-64bit-205000mW-Cascade lake-SP Xeon Platinum 8270-26Core-IT product-line dedicated EOP
41020785X86 series-FCLGA3647-2900MHz-1.6V/1.83V-64bit-205000mW-Cascade lake-SP Xeon Platinum 8268-24Core-IT product-line dedicated EOP
41020786X86 series-FCLGA3647-2400MHz-1.6V/1.83V-64bit-165000mW-Cascade lake-SP Xeon Platinum 8260-24Core-IT product-line dedicated EOP
41020787X86 series-FCLGA3647-2400MHz-1.6V/1.83V-64bit-165000mW-Cascade lake-SP Xeon Platinum 8260M-24Core-IT product-line dedicated EOP
41020788X86 series-FCLGA3647-2400MHz-1.6V/1.83V-64bit-165000mW-Cascade lake-SP Xeon Platinum 8260L-24Core-IT product-line dedicated EOP
41020790X86 series-FCLGA3647-3800MHz-1.6V/1.83V-64bit-105000mW-Cascade lake-SP Xeon Platinum 8256-4Core-IT product-line dedicated EOP
41020791X86 series-FCLGA3647-2200MHz-1.6V/1.83V-64bit-125000mW-Cascade lake-SP Xeon Platinum 8253-16Core-IT product-line dedicated EOP
41020792X86 series-FCLGA3647-3100MHz-1.6V/1.83V-64bit-200000mW-Cascade lake-SP Xeon Gold 6254-18Core-IT product-line dedicated EOP
41020793X86 series-FCLGA3647-2100MHz-1.6V/1.83V-64bit-150000mW-Cascade lake-SP Xeon Gold 6252-24Core-IT product-line dedicated EOP
41020794X86 series-FCLGA3647-2500MHz-1.6V/1.83V-64bit-150000mW-Cascade lake-SP Xeon Gold 6248-20Core-IT product-line dedicated EOP
41020795X86 series-FCLGA3647-3600MHz-1.6V/1.83V-64bit-150000mW-Cascade lake-SP Xeon Gold 6244-8Core-IT product-line dedicated EOP
41020796X86 series-FCLGA3647-2800MHz-1.6V/1.83V-64bit-150000mW-Cascade lake-SP Xeon Gold 6242-16Core-IT product-line dedicated EOP
41020797X86 series-FCLGA3647-2600MHz-1.6V/1.83V-64bit-150000mW-Cascade lake-SP Xeon Gold 6240-18Core-IT product-line dedicated EOP
41020799X86 series-FCLGA3647-2100MHz-1.6V/1.83V-64bit-125000mW-Cascade lake-SP Xeon Gold 6230-20Core-IT product-line dedicated EOP
41020800X86 series-FCLGA3647-3800MHz-1.6V/1.83V-64bit-105000mW-Cascade lake-SP Xeon Gold 5222-4Core-IT product-line dedicated EOP
41020801X86 series-FCLGA3647-2200MHz-1.6V/1.83V-64bit-125000mW-Cascade lake-SP Xeon Gold 5220-18Core-IT product-line dedicated EOM
41020802X86 series-FCLGA3647-2300MHz-1.6V/1.83V-64bit-125000mW-Cascade lake-SP Xeon Gold 5218-16Core-IT product-line dedicated EOP
41020803X86 series-FCLGA3647-2300MHz-1.6V/1.83V-64bit-125000mW-Cascade lake-SP Xeon Gold 5218B-16Core-IT product-line dedicated EOP
41020805X86 series-FCLGA3647-3000MHz-1.6V/1.83V-64bit-115000mW-Cascade lake-SP Xeon Gold 5217-8Core-IT product-line dedicated EOP
41020806X86 series-FCLGA3647-2500MHz-1.6V/1.83V-64bit-85000mW-Cascade lake-SP Xeon Gold 5215-10Core-IT product-line dedicated EOP
41020807X86 series-FCLGA3647-2500MHz-1.6V/1.83V-64bit-85000mW-Cascade lake-SP Xeon Gold 5215M-10Core-IT product-line dedicated EOP
41020808X86 series-FCLGA3647-2500MHz-1.6V/1.83V-64bit-85000mW-Cascade lake-SP Xeon Gold 5215L-10Core-IT product-line dedicated EOP
41020825X86 series-FCLGA3647-2600MHz-1.6V/1.83V-64bit-150000mW-Cascade lake-SP Xeon Gold 6240M-18Core-IT product-line dedicated EOP
41020826X86 series-FCLGA3647-3300MHz-1.6V/1.83V-64bit-130000mW-Cascade lake-SP Xeon Gold 6234-8Core-IT product-line dedicated EOP
41020827X86 series-FCLGA3647-2700MHz-1.6V/1.83V-64bit-125000mW-Cascade lake-SP Xeon Gold 6226-12Core-IT product-line dedicated EOP
41020831X86 series-FCLGA3647-2100MHz-1.6V/1.83V-64bit-140000mW-Cascade lake-SP Xeon Gold 6238-22Core-IT product-line dedicated EOP
41020833X86 series-FCLGA3647-2300MHz-1.6V/1.83V-64bit-125000mW-Cascade lake-SP Xeon Gold 6230N-20Core EOP
41020836X86 series-FCLGA3647-2300MHz-1.6V/1.83V-64bit-150000mW-Cascade lake-SP Xeon Gold 6252N-24Core EOP
41020841X86 series-FCLGA3647-3300MHz-1.6V/1.83V-64bit-165000mW-Cascade lake-SP Xeon Gold 6246-12Core-IT product-line dedicated EOP
41020844X86 series-FCLGA3647-2600MHz-1.6V/1.83V-64bit-150000mW-Cascade lake-SP Xeon Gold 6240L-18Core-IT product-line dedicated EOP
41020846X86 series-FCLGA3647-2100MHz-1.6V/1.83V-64bit-140000mW-Cascade lake-SP Xeon Gold 6238L-22Core-IT product-line dedicated EOP
90010339Liquid Manufactory Auxiliaries,Thermal Grease,X-23-7868-2D,Thermal Conductivity 3.6W/mK / 6.0W/mK,2g,Gap filling thermal conductive for customer use,1ml Current
21203892General Plastic Parts ,DKBA80659965.prt,clip SKX,2288 V5,/ EOP Engineer replace
14990482Connector Accessories,CPU Socket ILM,14990480,14990481,14030074,14030075,1:1:1:1,LGA3647 Skylake CPU Carrier EOP Engineer replace
41020798X86 series,FCLGA3647,2600MHz,1.6V/1.83V,64bit,150000mW,Cascade lake-SP Xeon Gold 6240Y-18Core-IT Product Dedicated EOP Field replaceable
41020789X86 series,FCLGA3647,2400MHz,1.6V/1.83V,64bit,165000mW,Cascade lake-SP Xeon Platinum 8260Y-24Core-IT Product Dedicated EOP Field replaceable
P/NDescription / SpecificationStatus
0251Y066memory module-TS200-2480-generic memory-DDR4 RDIMM-64GB-288pin-0.625ns-3200000KHz-1.2V-ECC-2Rank(4G*4bit)-overseas dedicated Current
0251Y070memory module-2288H V5-generic memory-DDR4 RDIMM-32GB-288pin-0.625ns-3200000KHz-1.2V-ECC-2Rank(2G*4bit)-overseas dedicated Current
0251Y170memory module-2288H V5-generic memory-DDR4-RDIMM-32GB-288pin-0.625ns-3200000KHz-1.2V-ECC-2Rank(2G*4bit)-XH Current
0251Y199memory module-2288H V6-generic memory-DDR4-RDIMM-64GB-288pin-0.625ns-3200000KHz-1.2V-ECC-2Rank(4G*4bit)-overseas dedicated-spec code Current
0251Y200memory module-2288H V6-generic memory-DDR4-RDIMM-16GB-288pin-0.625ns-3200000KHz-1.2V-ECC-2Rank(1G*8bit)-overseas dedicated-spec code Current
0251Y201memory module-2288H V6-generic memory-DDR4-RDIMM-32GB-288pin-0.625ns-3200000KHz-1.2V-ECC-2Rank(2G*4bit)-overseas dedicated-spec code Current
06200309-011generic memory-DDR4 RDIMM-32GB-288pin-0.625ns-3200000KHz-1.2V-ECC-2Rank(2G*4bit)-CXMT 1xnm Current
06200320-010generic memory-DDR4 RDIMM-16GB-288pin-0.625ns-3200000KHz-1.2V-ECC-2Rank(1G*8bit)-designated-model dedicated-Hynix 1ynm Current
06200320-014generic memory-DDR4 RDIMM-16GB-288pin-0.625ns-3200000KHz-1.2V-ECC-2Rank(1G*8bit)-internet dedicated-Samsung 1znm Current
06200321generic memory-DDR4 RDIMM-32GB-288pin-0.625ns-3200000KHz-1.2V-ECC-2Rank(2G*8bit)-SDP Current
06200323generic memory-DDR4 RDIMM-64GB-288pin-0.625ns-3200000KHz-1.2V-ECC-2Rank(4G*4bit)-SDP Current
06200323-014generic memory-DDR4 RDIMM-64GB-288pin-0.625ns-3200000KHz-1.2V-ECC-2Rank(4G*4bit)-designated-model dedicated-Hynix 1znm Current
06200328generic memory-DDR4-LRDIMM-128GB-288pin-0.625ns-3200000KHz-ECC-4Rank(4G*4bit) Current
0620Y064generic memory-DDR4-RDIMM-32GB-288pin-0.625ns-3200000KHz-1.2V-ECC-2Rank(2G*4bit)-spec code Current
0620Y066generic memory-DDR4-RDIMM-64GB-288pin-0.625ns-3200000KHz-1.2V-ECC-2Rank(4G*4bit)-SDP-spec code Current
0620Y067generic memory-DDR4-RDIMM-16GB-288pin-0.625ns-3200000KHz-1.2V-ECC-2Rank(1G*8bit)-SDP-spec code Current
02312LALfunction module-Server-generic memory-ruggedized memory-DCPMM-128GB-2666000KHz-ECC EOP
02312LAPfunction module-Server-generic memory-ruggedized memory-DCPMM-Intel Optane DC Persistent Memory(AEP)-256GB-2666000KHz-ECC EOP
02312LAQfunction module-Server-generic memory-ruggedized memory-DCPMM-Intel Optane DC Persistent Memory(AEP)-512GB-2666000KHz-ECC EOP
0251Y039memory module-3200-32G-generic memory-DDR4 RDIMM-32GB-288pin-0.625ns-3200000KHz-1.2V-ECC-2Rank(2G*4bit) EOP
0251Y051memory module-FusionServer-generic memory-DDR4 RDIMM-32GB-288pin-0.625ns-3200000KHz-1.2V-ECC-2Rank(2G*4bit)-for shipment EOM
0251Y065memory module-FusionServer V5-generic memory-DDR4 RDIMM-64GB-288pin-0.68ns-2933000KHz-1.2V-ECC-2Rank(4G*4bit) EOP
0251Y067memory module-TS200-2480-generic memory-DDR4 RDIMM-32GB-288pin-0.625ns-3200000KHz-1.2V-ECC-2Rank(2G*8bit)-overseas dedicated EOP
0251Y068memory module-2288H V6-generic memory-DDR4 RDIMM-16GB-288pin-0.625ns-3200000KHz-1.2V-ECC-2Rank(1G*8bit)-overseas dedicated EOM
0251Y069memory module-FusionServer V5-generic memory-DDR4 RDIMM-32GB-288pin-0.68ns-2933000KHz-1.2V-ECC-2Rank(2G*8bit)-overseas dedicated EOP
0251Y071memory module-FusionServer V5-generic memory-DDR4 RDIMM-32GB-288pin-0.68ns-2933000KHz-1.2V-ECC-2Rank(2G*4bit) EOP
0251Y072memory module-FusionServer V5-generic memory-DDR4 RDIMM-16GB-288pin-0.68ns-2933000KHz-1.2V-ECC-2Rank(1G*8bit) EOP
0251Y171memory module-FusionServer V5-generic memory-DDR4-RDIMM-64GB-288pin-0.625ns-3200000KHz-1.2V-ECC-2Rank(4G*4bit)-SDP-XH EOM
06200235generic memory-DDR4 LRDIMM-128GB-288pin-0.83ns-2400000KHz-1.2V-ECC-8Rank(2G*4bit)-4H TSV EOP
06200240generic memory-DDR4 RDIMM-16GB-288pin-0.75ns-2666000KHz-1.2V-ECC-2Rank(1G*8bit) EOM
06200241generic memory-DDR4 RDIMM-32GB-288pin-0.75ns-2666000KHz-1.2V-ECC-2Rank(2G*4bit) EOM
06200242generic memory-DDR4 LRDIMM-64GB-288pin-0.75ns-2666000KHz-1.2V-ECC-4Rank(2G*4bit) EOM
06200244generic memory-DDR4 RDIMM-8GB-288pin-0.75ns-2666000KHz-1.2V-ECC-1Rank(1G*8bit)-IT product-line dedicated EOP
06200257generic memory-DDR4 LRDIMM-128GB-288pin-0.75ns-2666000KHz-1.2-ECC-8Rank(2G*4bit)-4H TSV EOM
06200265generic memory-DDR4 RDIMM-16GB-288pin-0.75ns-2666000KHz-1.2V-ECC-2Rank(1G*8bit)-3-way OEM code EOP
06200266generic memory-DDR4 RDIMM-32GB-288pin-0.75ns-2666000KHz-1.2V-ECC-2Rank(2G*4bit)-3-way OEM code EOM
06200267generic memory-DDR4 LRDIMM-64GB-288pin-0.75ns-2666000KHz-1.2V-ECC-4Rank(2G*4bit)-3-way OEM code EOM
06200268generic memory-DDR4 RDIMM-8GB-288pin-0.75ns-2666000KHz-1.2V-ECC-1Rank(1G*8bit)-3-way OEM code EOP
06200277generic memory-DDR4 RDIMM-16GB-288pin-0.75ns-2666000KHz-1.2-ECC-1rank(2G*4bit) EOP
06200282generic memory-DDR4 RDIMM-64GB-288pin-0.68ns-2933000KHz-1.2V-ECC-2Rank(4G*4bit)-SDP EOM
06200286generic memory-DDR4 RDIMM-16GB-288pin-0.68ns-2933000KHz-1.2V-ECC-2Rank(1G*8bit)-server dedicated EOM
06200288generic memory-DDR4 RDIMM-32GB-288pin-0.68ns-2933000KHz-1.2V-ECC-2Rank(2G*4bit)-server dedicated EOM
06200289generic memory-DDR4 RDIMM-128GB-288pin-0.68ns-2933000KHz-1.2V-ECC-4Rank(4G*4bit)-3DS EOM
06200303generic memory-DDR4 RDIMM-32GB-288pin-0.68ns-2933000KHz-1.2V-ECC-2Rank(2G*4bit)-OEM code EOM
06200304generic memory-DDR4 RDIMM-16GB-288pin-0.68ns-2933000KHz-1.2V-ECC-1Rank(2G*4bit)-OEM code EOM
06200307generic memory-DDR4 RDIMM-8GB-288pin-0.68ns-2933000KHz-1.2V-ECC-1Rank(1G*8bit) EOM
06200309generic memory-DDR4 RDIMM-32GB-288pin-0.625ns-3200000KHz-1.2V-ECC-2Rank(2G*4bit) EOM
06200309-012generic memory-DDR4 RDIMM-32GB-288pin-0.625ns-3200000KHz-1.2V-ECC-2Rank(2G*4bit)-Hynix 1znm advanced process node EOM
06200309-016generic memory-DDR4 RDIMM-32GB-288pin-0.625ns-3200000KHz-1.2V-ECC-2Rank(2G*4bit)-designated-model dedicated-Samsung 1znm EOM
06200309-023generic memory-DDR4 RDIMM-32GB-288pin-0.625ns-3200000KHz-1.2V-ECC-2Rank(2G*4bit)-Q4 stock EOM
06200317generic memory-DDR4 RDIMM-32GB-288pin-0.68ns-2933000KHz-1.2V-ECC-2Rank(2G*8bit) EOM
06200320generic memory-DDR4 RDIMM-16GB-288pin-0.625ns-3200000KHz-1.2V-ECC-2Rank(1G*8bit)-SDP EOM
06200320-012generic memory-DDR4 RDIMM-16GB-288pin-0.625ns-3200000KHz-1.2V-ECC-2Rank(1G*8bit)-designated-model dedicated-Hynix 1znm EOM
06200323-023generic memory-DDR4 RDIMM-64GB-288pin-0.625ns-3200000KHz-1.2V-ECC-2Rank(4G*4bit)-SDP-SAMSUNG-1z nm EOM
06200329generic memory-DDR4 RDIMM-64GB-288pin-0.68ns-2933000KHz-1.2V-ECC-2Rank(4G*4bit)-SDP EOM
06200330generic memory-DDR4 RDIMM-32GB-288pin-0.68ns-2933000KHz-1.2V-ECC-2Rank(2G*8bit) EOM
06200219Memory Module,DDR4 LRDIMM,64GB,288pin,0.8ns,2400000KHz,1.2V,ECC,4Rank(2G*4bit) EOP Field replaceable
06200212Memory Module,DDR4 RDIMM,8GB,288pin,0.8ns,2400000KHz,1.2V,ECC,2Rank(512M*8bit) EOP Field replaceable
06200224Memory Module,DDR4 RDIMM,32GB,288pin,0.83ns,2400000KHz,1.2V,ECC,2Rank(2G*4bit) EOP Field replaceable
06200225Memory Module,DDR4 RDIMM,16GB,288pin,0.83ns,2400000KHz,1.2V,ECC,2Rank(1G*8bit) EOP Field replaceable
06200272Memory Module,DDR4 LRDIMM,32GB,288pin,0.75ns,2666000KHz,1.2,ECC,2Rank(2G*4bit) EOP Field replaceable
P/NDescription / SpecificationStatus
02312GNRfunction module-Servers-SSD-480GB-SATA 6Gb/s-read-intensive-PM883 series-2.5 inch(2.5 inch bracket)-IT product-line server dedicated Current
02312GNTfunction module-Servers-SSD-960GB-SATA 6Gb/s-read-intensive-PM883 series-2.5 inch(2.5 inch bracket)-IT product-line server dedicated Current
02312RBSfunction module-server product-generic drive-1800GB-SAS 12Gb/s-10000rpm-2.5inch-128MB-hot-swap-internal-2.5 inch bracket Current
02312RBVfunction module-Server-generic drive-1200GB-SAS 12Gb/s-10000rpm-2.5inch-128MB and above-hot-swap-internal-2.5 inch bracket Current
02312RBWfunction module-Server-generic drive-600GB-SAS 12Gb/s-10000rpm-2.5inch-128MB and above-hot-swap-internal-2.5 inch bracket Current
02312RCMfunction module-Servers-generic drive-2400GB-SAS 12Gb/s-10K rpm-256MB-2.5 inch(2.5 inch bracket) Current
0255Y006SSD module-Servers-SSD-480GB-SATA 6Gb/s-mixed read-write-PM897 series-2.5 inch(2.5 inch bracket) Current
0255Y008SSD module-Servers-SSD-960GB-SATA 6Gb/s-mixed read-write-PM897 series-2.5 inch(2.5 inch bracket) Current
0255Y010SSD module-Servers-SSD-1920GB-SATA 6Gb/s-mixed read-write-PM897 series-2.5 inch(2.5 inch bracket) Current
0255Y012SSD module-Servers-SSD-3840GB-SATA 6Gb/s-mixed read-write-PM897 series-2.5 inch(2.5 inch bracket) Current
0255Y016SSD module-Servers-SSD-480GB-SATA 6Gb/s-read-intensive-PM893 series-2.5 inch(2.5 inch bracket) Current
0255Y018SSD module-Servers-SSD-960GB-SATA 6Gb/s-read-intensive-PM893 series-2.5 inch(2.5 inch bracket) Current
0255Y020SSD module-Servers-SSD-1920GB-SATA 6Gb/s-read-intensive-PM893 series-2.5 inch(2.5 inch bracket) Current
0255Y022SSD module-Servers-SSD-3840GB-SATA 6Gb/s-read-intensive-PM893 series-2.5 inch(2.5 inch bracket) Current
0255Y165SSD module-Servers-SSD-3200GB-SAS 12Gb/s-mixed read-write-UH630a-Y series-2.5 inch(2.5 inch bracket) Current
0255YABCSSD module-Servers-SSD-3200GB-SAS 12Gb/s-mixed read-write-UM631a-Y series-2.5 inch(2.5 inch bracket)-shell optimized Current
0255YESUSSD module-Servers-SSD-3840GB-SATA 6Gb/s-read-intensive-PM893 series-2.5 inch(2.5 inch bracket) Current
0255YETPSSD module-Servers-SSD-3840GB-SATA 6Gb/s-mixed read-write-PM897 series-2.5 inch(2.5 inch bracket) Current
0255YEUVSSD module-Servers-SSD-480GB-SATA 6Gb/s-read-intensive-PM893 series-2.5 inch(2.5 inch bracket) Current
0255YEUWSSD module-Servers-SSD-960GB-SATA 6Gb/s-mixed read-write-PM897 series-2.5 inch(2.5 inch bracket) Current
0255YEXKSSD module-Servers-SSD-1920GB-SATA 6Gb/s-read-intensive-PM893 series-2.5 inch(2.5 inch bracket) Current
0255YFAESSD module-Servers-SSD-1920GB-SATA 6Gb/s-mixed read-write-PM897 series-2.5 inch(2.5 inch bracket) Current
0255YFBFSSD module-Servers-SSD-960GB-SATA 6Gb/s-read-intensive-PM893 series-2.5 inch(2.5 inch bracket) Current
02310YCHfunction module-server product-generic drive-1000GB-SATA-7200rpm-2.5"-64M-hot-swap-internal-bracket EOP
02311AYFfunction module-Server-generic drive-600GB-SAS 12Gb/s-15K rpm-128MB-2.5 inch(2.5 inch bracket) EOP
02311EXXfunction module-Server-generic drive-300GB-SAS 12Gb/s-15K rpm-128MB-2.5 inch(2.5 inch bracket) EOP
02311FMRfunction module-server product-generic drive-1800GB-SAS 12Gb/s-10000rpm-2.5inch-128MB-hot-swap-internal-2.5 inch bracket-spare-parts dedicated,note required when ordering:only Seagate/HGST drive EOP
02311HAKfunction module-Server-generic drive-300GB-SAS 12Gb/s-10000rpm-2.5inch-128MB and above-hot-swap-internal-2.5 inch bracket-spare-parts dedicated,note required when ordering:only Seagate/HGST drive EOM
02311HALfunction module-Server-generic drive-900GB-SAS 12Gb/s-10000rpm-2.5inch-128MB and above-hot-swap-internal-2.5 inch bracket EOP
02311HANfunction module-Server-generic drive-1200GB-SAS 12Gb/s-10000rpm-2.5inch-128MB and above-hot-swap-internal-2.5 inch bracket-spare-parts dedicated,note required when ordering:only Seagate/HGST drive EOM
02311HAPfunction module-Server-generic drive-600GB-SAS 12Gb/s-10000rpm-2.5inch-128MB and above-hot-swap-internal-2.5 inch bracket-spare-parts dedicated,note required when ordering:only Seagate/HGST drive EOP
02311HGXfunction module-Server-generic drive-2000GB-SATA 6Gb/s-7.2K rpm-128MB-2.5 inch(2.5 inch bracket) EOP
02311JCYfunction module-Server-generic drive-1000GB-NL SAS 12Gb/s-7.2K rpm-128MB-2.5 inch(2.5 inch bracket) EOP
02311JDAfunction module-Server-generic drive-2000GB-NL SAS 12Gb/s-7.2K rpm-128MB-2.5 inch(2.5 inch bracket) EOP
02311TJXfunction module-Servers-SSD-480GB-SATA 6Gb/s-read-intensive-CloudSpeed2 series-2.5 inch(2.5 inch bracket)-LE series EOP
02311TJYfunction module-Servers-SSD-800GB-SATA 6Gb/s-read-intensive-CloudSpeed2 series-2.5 inch(2.5 inch bracket)-LE series EOP
02311TKAfunction module-Servers-SSD-960GB-SATA 6Gb/s-read-intensive-CloudSpeed2 series-2.5 inch(2.5 inch bracket)-LE series EOP
02311TKBfunction module-Servers-SSD-1600GB-SATA 6Gb/s-read-intensive-CloudSpeed2 series-2.5 inch(2.5 inch bracket)-LE series EOP
02311TKCfunction module-Servers-SSD-1920GB-SATA 6Gb/s-read-intensive-CloudSpeed2 series-2.5 inch(2.5 inch bracket)-LE series EOP
02311UYEfunction module-Servers-SSD-3840GB-SATA 6Gb/s-read-intensive-PM863A series-2.5 inch(2.5 inch bracket)-LE series EOP
02311VCQfunction module-Servers-SSD-1920GB-SATA 6Gb/s-mixed read-write-SM863a series-2.5 inch(2.5 inch bracket)-VE series EOP
02311VHRfunction module-Servers-SSD-240GB-SATA 6Gb/s-read-intensive-PM863a series-2.5 inch(2.5 inch bracket)-LE series EOP
02311VHSfunction module-Servers-SSD-480GB-SATA 6Gb/s-read-intensive-PM863a series-2.5 inch(2.5 inch bracket)-LE series EOP
02311VHTfunction module-Servers-SSD-960GB-SATA 6Gb/s-read-intensive-PM863a series-2.5 inch(2.5 inch bracket)-LE series EOP
02311VHUfunction module-Servers-SSD-1920GB-SATA 6Gb/s-read-intensive-PM863a series-2.5 inch(2.5 inch bracket)-LE series EOP
02311VJCfunction module-Servers-SSD-480GB-SATA 6Gb/s-mixed read-write-SM863a series-2.5 inch(2.5 inch bracket)-VE series EOP
02311VJFfunction module-Servers-SSD-960GB-SATA 6Gb/s-mixed read-write-SM863a series-2.5 inch(2.5 inch bracket)-VE series EOP
02311WNKfunction module-ES3620S V3-SSD-800GB-SAS 12Gb/s-mixed read-write-3DWPD-2.5 inch(2.5 inch bracket)-VE series EOP
02311WNMfunction module-ES3620S V3-SSD-1600GB-SAS 12Gb/s-mixed read-write-3DWPD-2.5 inch(2.5 inch bracket)-VE series EOS
02311WNPfunction module-ES3620S V3-SSD-3200GB-SAS 12Gb/s-mixed read-write-3DWPD-2.5 inch(2.5 inch bracket)-VE series EOS
02311WNSfunction module-ES3520S V3-SSD-960GB-SAS 12Gb/s-read-intensive-1DWPD-2.5 inch(2.5 inch bracket)-LE series EOS
02311WNUfunction module-ES3520S V3-SSD-1920GB-SAS 12Gb/s-read-intensive-1DWPD-2.5 inch(2.5 inch bracket)-LE series EOS
02311WNXfunction module-ES3520S V3-SSD-3840GB-SAS 12Gb/s-read-intensive-1DWPD-2.5 inch(2.5 inch bracket)-LE series EOS
02311WYVfunction module-Servers-generic drive-900GB-SAS 12Gb/s-15K rpm-256MB and above-2.5 inch(2.5 inch bracket) EOP
02311YTBfunction module-ES3720S V3-SSD-400GB-SAS 12Gb/s-write-intensive-15DWPD-2.5 inch(2.5 inch bracket)-ME series EOS
02311YTHfunction module-ES3720S V3-SSD-800GB-SAS 12Gb/s-write-intensive-15DWPD-2.5 inch(2.5 inch bracket)-ME series EOS
02311YTJfunction module-ES3720S V3-SSD-1600GB-SAS 12Gb/s-write-intensive-15DWPD-2.5 inch(2.5 inch bracket)-ME series EOS
02312ALTfunction module-Servers-SSD-240GB-SATA 6Gb/s-mixed read-write-SM863a series-2.5 inch(2.5 inch bracket)-VE series EOP
02312DFDfunction module-Servers-generic drive-2400GB-SAS 12Gb/s-10K rpm-256MB-2.5 inch(2.5 inch bracket)-spare-parts dedicated,note required when ordering:only Seagate/HGST drive EOP
02312DXSfunction module-Servers-SSD-480GB-SATA 6Gb/s-read-intensive-5200 ECO series-2.5 inch(2.5 inch bracket)-IT product-line server dedicated EOP
02312DXTfunction module-Servers-SSD-960GB-SATA 6Gb/s-read-intensive-5200 ECO series-2.5 inch(2.5 inch bracket)-IT product-line server dedicated EOP
02312DYBfunction module-Servers-SSD-960GB-SATA 6Gb/s-mixed read-write-5200 PRO series-2.5 inch(2.5 inch bracket)-IT product-line server dedicated EOP
02312DYCfunction module-Servers-SSD-1920GB-SATA 6Gb/s-read-intensive-5200 ECO series-2.5 inch(2.5 inch bracket)-IT product-line server dedicated EOP
02312DYFfunction module-Servers-SSD-1920GB-SATA 6Gb/s-mixed read-write-5200 PRO series-2.5 inch(2.5 inch bracket)-IT product-line server dedicated EOP
02312DYGfunction module-Servers-SSD-3840GB-SATA 6Gb/s-read-intensive-5200 ECO series-2.5 inch(2.5 inch bracket)-LE series-IT product-line server dedicated EOP
02312FRCfunction module-Servers-ES3500S V5-HW SSD-Disk Unit-960GB SAS 12Gb/s-read-intensive-2.5 inch(2.5 inch bracket) EOP
02312FREfunction module-Servers-ES3500S V5-HW SSD-Disk Unit-1920GB SAS 12Gb/s-read-intensive-2.5 inch(2.5 inch bracket) EOP
02312FRGfunction module-Servers-ES3500S V5-HW SSD-Disk Unit-3840GB SAS 12Gb/s-read-intensive-2.5 inch(2.5 inch bracket) EOP
02312FRJfunction module-Servers-ES3500S V5-HW SSD-Disk Unit-7680GB SAS 12Gb/s-read-intensive-2.5 inch(2.5 inch bracket) EOP
02312FRLfunction module-Servers-ES3600S V5-HW SSD-Disk Unit-800GB SAS 12Gb/s-mixed read-write-2.5 inch(2.5 inch bracket) EOP
02312FRNfunction module-Servers-ES3600S V5-HW SSD-Disk Unit-1600GB SAS 12Gb/s-mixed read-write-2.5 inch(2.5 inch bracket) EOP
02312FRQfunction module-Servers-ES3600S V5-HW SSD-Disk Unit-3200GB SAS 12Gb/s-mixed read-write-2.5 inch(2.5 inch bracket) EOP
02312FRTfunction module-Servers-ES3600S V5-HW SSD-Disk Unit-6400GB SAS 12Gb/s-mixed read-write-2.5 inch(2.5 inch bracket) EOP
02312GNEfunction module-Servers-SSD-240GB-SATA 6Gb/s-read-intensive-S4510 series-2.5 inch(2.5 inch bracket)-IT product-line server dedicated EOP
02312GNFfunction module-Servers-SSD-480GB-SATA 6Gb/s-read-intensive-S4510 series-2.5 inch(2.5 inch bracket)-IT product-line server dedicated EOP
02312GNJfunction module-Servers-SSD-960GB-SATA 6Gb/s-read-intensive-S4510 series-2.5 inch(2.5 inch bracket)-IT product-line server dedicated EOP
02312GNKfunction module-Servers-SSD-1920GB-SATA 6Gb/s-read-intensive-S4510 series-2.5 inch(2.5 inch bracket)-IT product-line server dedicated EOP
02312GNMfunction module-Servers-SSD-3840GB-SATA 6Gb/s-read-intensive-S4510 series-2.5 inch(2.5 inch bracket)-IT product-line server dedicated EOP
02312GNPfunction module-Servers-SSD-240GB-SATA 6Gb/s-read-intensive-PM883 series-2.5 inch(2.5 inch bracket)-IT product-line server dedicated EOM
02312GNWfunction module-Servers-SSD-1920GB-SATA 6Gb/s-read-intensive-PM883 series-2.5 inch(2.5 inch bracket)-IT product-line server dedicated EOM
02312GTQfunction module-Servers-SSD-240GB-SATA 6Gb/s-mixed read-write-S4610 series-2.5 inch(2.5 inch bracket)-IT product-line server dedicated EOP
02312GTRfunction module-Servers-SSD-480GB-SATA 6Gb/s-mixed read-write-S4610 series-2.5 inch(2.5 inch bracket)-IT product-line server dedicated EOP
02312GTSfunction module-Servers-SSD-960GB-SATA 6Gb/s-mixed read-write-S4610 series-2.5 inch(2.5 inch bracket)-IT product-line server dedicated EOP
02312GTTfunction module-Servers-SSD-1920GB-SATA 6Gb/s-mixed read-write-S4610 series-2.5 inch(2.5 inch bracket)-IT product-line server dedicated EOP
02312GUAfunction module-Servers-SSD-240GB-SATA 6Gb/s-mixed read-write-SM883 series-2.5 inch(2.5 inch bracket)-IT product-line server dedicated EOP
02312GUCfunction module-Servers-SSD-480GB-SATA 6Gb/s-mixed read-write-SM883 series-2.5 inch(2.5 inch bracket)-IT product-line server dedicated EOP
02312GUEfunction module-Servers-SSD-960GB-SATA 6Gb/s-mixed read-write-SM883 series-2.5 inch(2.5 inch bracket)-IT product-line server dedicated EOP
02312GUFfunction module-Servers-SSD-1920GB-SATA 6Gb/s-mixed read-write-SM883 series-2.5 inch(2.5 inch bracket)-IT product-line server dedicated EOM
02312JAAfunction module-Servers-ES3500S V5-HW SSD-Disk Unit-480GB SAS 12Gb/s-read-intensive-2.5 inch(2.5 inch bracket) EOP
02312JLRfunction module-Servers-ES3500S V5-HW SSD-Disk Unit-15360GB SAS 12Gb/s-read-intensive-2.5 inch(2.5 inch bracket) EOP
02312KGGfunction module-Servers-SSD-3840GB-SATA 6Gb/s-mixed read-write-S4610 series-2.5 inch(2.5 inch bracket)-IT product-line server dedicated EOP
02312KGHfunction module-Servers-SSD-3840GB-SATA 6Gb/s-mixed read-write-SM883 series-2.5 inch(2.5 inch bracket)-IT product-line server dedicated EOP
02312QRQfunction module-Servers-ES3510S V5-HW SSD-Disk Unit-960GB SAS 12Gb/s-read-intensive-2.5 inch(2.5 inch bracket) EOP
02312QVRfunction module-Servers-ES3610S V5-HW SSD-Disk Unit-800GB SAS 12Gb/s-mixed read-write-2.5 inch(2.5 inch bracket) EOP
02312RBTfunction module-Server-generic drive-300GB-SAS 12Gb/s-10000rpm-2.5inch-128MB and above-hot-swap-internal-2.5 inch bracket EOP
02312REYfunction module-Servers-ES3510S V5-HW SSD-Disk Unit-3840GB SAS 12Gb/s-read-intensive-2.5 inch(2.5 inch bracket) EOP
02312RFCfunction module-Servers-ES3510S V5-HW SSD-Disk Unit-7680GB SAS 12Gb/s-read-intensive-2.5 inch(2.5 inch bracket) EOP
02312RNGfunction module-Server-generic drive-1200GB-SAS 12Gb/s-10000rpm-2.5inch-128MB and above-hot-swap-internal-2.5 inch bracket-third-party purchased RAID standard-card dedicated EOP
02312RNHfunction module-Server-generic drive-1800GB-SAS 12Gb/s-10000rpm-2.5inch-128MB-hot-swap-internal-2.5 inch bracket-third-party purchased RAID standard-card dedicated EOP
02312RNJfunction module-Servers-generic drive-2400GB-SAS 12Gb/s-10K rpm-256MB-2.5 inch(2.5 inch bracket)-third-party purchased RAID standard-card dedicated EOP
02312XAKfunction module-Servers-SSD-480GB-SATA 6Gb/s-read-intensive-ER2-CD series-2.5 inch(2.5 inch bracket)-IT product-line server dedicated EOM
02312XAMfunction module-Servers-SSD-960GB-SATA 6Gb/s-read-intensive-ER2-CD series-2.5 inch(2.5 inch bracket)-IT product-line server dedicated EOP
02312YQAfunction module-Servers-ES3510S V5-HW SSD-Disk Unit-960GB SAS 12Gb/s-read-intensive-2.5 inch(2.5 inch bracket) EOP
02312YQCfunction module-Servers-ES3610S V5-HW SSD-Disk Unit-800GB SAS 12Gb/s-mixed read-write-2.5 inch(2.5 inch bracket) EOP
02313DHRfunction module-Servers-SSD-240GB-SATA 6Gb/s-read-intensive-ER2-CD series-2.5 inch(2.5 inch bracket)-IT product-line server dedicated EOP
02313DHTfunction module-Servers-SSD-1920GB-SATA 6Gb/s-read-intensive-ER2-CD series-2.5 inch(2.5 inch bracket)-IT product-line server dedicated EOP
02313ELLfunction module-Servers-SSD-960GB-SAS 12Gb/s-read-intensive-PM1643a series-2.5 inch(2.5 inch bracket) EOP
02313ELYfunction module-Servers-SSD-1920GB-SAS 12Gb/s-read-intensive-PM1643a series-2.5 inch(2.5 inch bracket) EOM
02313EMBfunction module-Servers-SSD-3840GB-SAS 12Gb/s-read-intensive-PM1643a series-2.5 inch(2.5 inch bracket) EOM
02313EMDfunction module-Servers-SSD-7680GB-SAS 12Gb/s-read-intensive-PM1643a series-2.5 inch(2.5 inch bracket) EOP
0255Y014SSD module-Servers-SSD-240GB-SATA 6Gb/s-read-intensive-PM893 series-2.5 inch(2.5 inch bracket) EOP
0255Y053SSD module-Servers-SSD-240GB-SATA 6Gb/s-read-intensive-SE005 series-2.5 inch(2.5 inch bracket) EOP
0255Y055SSD module-Servers-SSD-480GB-SATA 6Gb/s-read-intensive-SE005 series-2.5 inch(2.5 inch bracket) EOM
0255Y057SSD module-Servers-SSD-960GB-SATA 6Gb/s-read-intensive-SE005 series-2.5 inch(2.5 inch bracket) EOM
0255Y059SSD module-Servers-SSD-1920GB-SATA 6Gb/s-read-intensive-SE005 series-2.5 inch(2.5 inch bracket) EOM
0255Y071SSD module-Servers-SSD-960GB-SAS 12Gb/s-read-intensive-UH610a-K series-2.5 inch(2.5 inch bracket) EOM
0255Y105SSD module-Servers-SSD-240GB-SATA 6Gb/s-read-intensive-ES500 series-2.5 inch(2.5 inch bracket) EOP
0255Y107SSD module-Servers-SSD-480GB-SATA 6Gb/s-read-intensive-ES500 series-2.5 inch(2.5 inch bracket) EOP
0255Y109SSD module-Servers-SSD-960GB-SATA 6Gb/s-read-intensive-ES500 series-2.5 inch(2.5 inch bracket) EOM
0255Y111SSD module-Servers-SSD-1920GB-SATA 6Gb/s-read-intensive-ES500 series-2.5 inch(2.5 inch bracket) EOM
0255Y153SSD module-Servers-SSD-3840GB-SAS 12Gb/s-read-intensive-UH610a-K series-2.5 inch(2.5 inch bracket) EOP
0255Y157SSD module-Servers-SSD-1920GB-SAS 12Gb/s-read-intensive-UH610a-Y series-2.5 inch(2.5 inch bracket) EOM
0255Y159SSD module-Servers-SSD-3840GB-SAS 12Gb/s-read-intensive-UH610a-Y series-2.5 inch(2.5 inch bracket) EOM
0255Y161SSD module-Servers-SSD-7680GB-SAS 12Gb/s-read-intensive-UH610a-Y series-2.5 inch(2.5 inch bracket) EOM
0255Y163SSD module-Servers-SSD-3200GB-SAS 12Gb/s-mixed read-write-UH630a-K series-2.5 inch(2.5 inch bracket) EOM
0255Y174SSD module-Servers-SSD-960GB-SAS 12Gb/s-read-intensive-UM611a-Y series-2.5 inch(2.5 inch bracket) EOM
0255Y176SSD module-Servers-SSD-3840GB-SAS 12Gb/s-read-intensive-UM611a-Y series-2.5 inch(2.5 inch bracket) EOM
0255Y207SSD module-Servers-SSD-1920GB-SAS 12Gb/s-read-intensive-UM611a-Y series-2.5 inch(2.5 inch bracket) EOP
0255Y209SSD module-Servers-SSD-3200GB-SAS 12Gb/s-mixed read-write-UM631a-Y series-2.5 inch(2.5 inch bracket) EOP
0255Y638SSD module-Servers-SSD-240GB-SATA 6Gb/s-read-intensive-ES500 series-2.5 inch(2.5 inch bracket)-global EOP
0255Y640SSD module-Servers-SSD-480GB-SATA 6Gb/s-read-intensive-ES500 series-2.5 inch(2.5 inch bracket)-global EOP
0255Y642SSD module-Servers-SSD-960GB-SATA 6Gb/s-read-intensive-ES500 series-2.5 inch(2.5 inch bracket)-global EOM
0255Y644SSD module-Servers-SSD-1920GB-SATA 6Gb/s-read-intensive-ES500 series-2.5 inch(2.5 inch bracket)-global EOM
0255YAAVSSD module-Servers-SSD-3840GB-SAS 12Gb/s-read-intensive-UM611a-Y series-2.5 inch(2.5 inch bracket)-shell optimized EOP
0255YAAXSSD module-Servers-SSD-960GB-SAS 12Gb/s-read-intensive-UM611a-Y series-2.5 inch(2.5 inch bracket)-shell optimized EOP
0255YABASSD module-Servers-SSD-1920GB-SAS 12Gb/s-read-intensive-UM611a-Y series-2.5 inch(2.5 inch bracket)-shell optimized EOP
02312GNHFunction Module,Servers,SSD,960GB,SATA 6Gb/s,Read Intensive,S4510 Series,2.5inch(3.5inch Drive Bay),IT Server Dedicated Current Field replaceable
02312GNGFunction Module,Servers,SSD,480GB,SATA 6Gb/s,Read Intensive,S4510 Series,2.5inch(3.5inch Drive Bay),IT Server Dedicated Current Field replaceable
02312FUFFunction Module,Servers,ES3500S V5,HW SSD,Disk Unit,3840GB SAS 12Gb/s,Read Intensive,2.5inch(3.5inch Drive Bay) EOP Field replaceable
02312FUKFunction Module,Servers,ES3600S V5,HW SSD,Disk Unit,3200GB SAS 12Gb/s,Mixed Use,2.5inch(3.5inch Drive Bay) EOP Field replaceable
02312GTNFunction Module,Servers,SSD,960GB,SATA 6Gb/s,Mixed Use,S4610 Series,2.5inch(3.5inch Drive Bay),IT Server Dedicated Current Field replaceable
02312GTMFunction Module,Servers,SSD,480GB,SATA 6Gb/s,Mixed Use,S4610 Series,2.5inch(3.5inch Drive Bay),IT Server Dedicated Current Field replaceable
02312GTXFunction Module,Servers,SSD,960GB,SATA 6Gb/s,Mixed Use,SM883 Series,2.5inch(3.5inch Drive Bay),IT Server Dedicated EOP Field replaceable
02312GTWFunction Module,Servers,SSD,480GB,SATA 6Gb/s,Mixed Use,SM883 Series,2.5inch(3.5inch Drive Bay),IT Server Dedicated EOP Field replaceable
0255Y031SSD Module,Servers,SSD,7680GB,NVMe PCIe,Read Intensive,UH810a-K Series,2.5inch(2.5inch Drive Bay) Current Field replaceable
02312FPRFunction Module,Servers,ES3500P V5 SSD,1000GB,NVMe PCIe,Read Intensive,2.5inch(2.5inch Drive Bay) EOP Field replaceable
02312FPXFunction Module,Servers,ES3500P V5 SSD,2000GB,NVMe PCIe,Read Intensive,2.5inch(2.5inch Drive Bay) EOP Field replaceable
02312FQBFunction Module,Servers,ES3500P V5 SSD,4000GB,NVMe PCIe,Read Intensive,2.5inch(2.5inch Drive Bay) EOP Field replaceable
02312FQDFunction Module,Servers,ES3500P V5 SSD,8000GB,NVMe PCIe,Read Intensive,2.5inch(2.5inch Drive Bay) EOP Field replaceable
02312FQSFunction Module,Servers,ES3600P V5 SSD,800GB,NVMe PCIe,Mixed Use,2.5inch(2.5inch Drive Bay) EOP Field replaceable
02312FQVFunction Module,Servers,ES3600P V5 SSD,1600GB,NVMe PCIe,Mixed Use,2.5inch(2.5inch Drive Bay) EOP Field replaceable
02311MRNFunction Module,Servers,ES3600P V3 SSD,3200GB,NVMe PCIe,Mixed Use,3 DWPD,2.5inch(2.5inch Drive Bay) EOP Field replaceable
02312FQWFunction Module,Servers,ES3600P V5 SSD,3200GB,NVMe PCIe,Mixed Use,2.5inch(2.5inch Drive Bay) EOP Field replaceable
02312FRAFunction Module,Servers,ES3600P V5 SSD,6400GB,NVMe PCIe,Mixed Use,2.5inch(2.5inch Drive Bay) EOP Field replaceable
02311MRXFunction Module,Servers,ES3600P V3 SSD,1200GB,NVMe PCIe,Mixed Use,3 DWPD,2.5inch(2.5inch Drive Bay) EOP Field replaceable
02312HESFunction Module,Servers,SSD,8000GB,NVMe PCIe,Read Intensive,P4510 Series,2.5inch(2.5inch Drive Bay),IT Server Dedicated Current Field replaceable
02311MSAFunction Module,Servers,ES3600P V3 SSD,1600GB,NVMe PCIe,Mixed Use,3 DWPD,2.5inch(2.5inch Drive Bay) EOP Field replaceable
02311NUDFunction Module,Servers,ES3500P V3 SSD,1200GB,NVMe PCIe,Read Intensive,2.5inch(2.5inch Drive Bay),LE Series EOP Field replaceable
02311MSCFunction Module,Servers,ES3500P V3 SSD,2000GB,NVMe PCIe,Read Intensive,1 DWPD,2.5inch(2.5inch Drive Bay) EOP Field replaceable
02311MSEFunction Module,Servers,ES3500P V3 SSD,3200GB,NVMe PCIe,Read Intensive,1 DWPD,2.5inch(2.5inch Drive Bay) EOP Field replaceable
02311VVCFunction Module,Server,HDD,10000GB,NL SAS 12Gb/s,7.2K rpm,256MB,3.5inch(3.5inch Drive Bay) EOP Field replaceable
02311TRTFunction Module,Servers,SSD,240GB,SATA 6Gb/s,Read Intensive,S3520 Series,2.5inch(2.5inch Drive Bay),LE Series EOP Field replaceable
02311TRVFunction Module,Servers,SSD,800GB,SATA 6Gb/s,Read Intensive,S3520 Series,2.5inch(2.5inch Drive Bay),LE Series EOP Field replaceable
02311TRUFunction Module,Servers,SSD,480GB,SATA 6Gb/s,Read Intensive,S3520 Series,2.5inch(2.5inch Drive Bay),LE Series EOP Field replaceable
02311TRXFunction Module,Servers,SSD,1600GB,SATA 6Gb/s,Read Intensive,S3520 Series,2.5inch(2.5inch Drive Bay),LE Series EOP Field replaceable
02311TRWFunction Module,Servers,SSD,1200GB,SATA 6Gb/s,Read Intensive,2.5inch(2.5inch Drive Bay),LE Series,S3520 Series EOP Field replaceable
0255Y134SSD Module,Servers,SSD,6400GB,NVMe PCIe,Mixed Use,UH830a-K Series,2.5inch(2.5inch Drive Bay) Current Field replaceable
02311TTSFunction Module,Servers,SSD,960GB,SATA 6Gb/s,Read Intensive,S3520 Series,2.5inch(2.5inch Drive Bay),LE Series EOP Field replaceable
02311UFMFunction Module,Servers,ES3600P V3 SSD,800GB,NVMe PCIe,Mixed Use,3 DWPD,2.5inch(2.5inch Drive Bay),VE Series EOP Field replaceable
02312DBHFunction Module,Servers,SSD,1000GB,NVMe PCIe,Read Intensive,P4510 Series,2.5inch(2.5inch Drive Bay),LE Series,IT Server Dedicated Current Field replaceable
02311UGCFunction Module,Servers,ES3500P V3 SSD,800GB,NVMe PCIe,Read Intensive,2.5inch(2.5inch Drive Bay),LE Series EOP Field replaceable
02312DBTFunction Module,Servers,SSD,4000GB,NVMe PCIe,Read Intensive,P4510 Series,2.5inch(2.5inch Drive Bay),LE Series,IT Server Dedicated Current Field replaceable
02311SCPFunction Module,Servers,ES3600P V3 SSD,2000GB,NVMe PCIe,Mixed Use,3 DWPD,2.5inch(2.5inch Drive Bay) EOP Field replaceable
02311YBRFunction Module,Servers,ES3500P V3 SSD,4000GB,NVMe PCIe,Read Intensive,0.3 DWPD,2.5inch(2.5inch Drive Bay),LE Series EOP Field replaceable
02311HAGFunction Module,Servers,SSD,800GB,SAS 12Gb/s,Write Intensive,Sunset Cove Plus Series,2.5inch(2.5inch Drive Bay),ME Series EOP Field replaceable
02311HAHFunction Module,Servers,SSD,400GB,SAS 12Gb/s,Write Intensive,Sunset Cove Plus Series,2.5inch(2.5inch Drive Bay),ME Series EOP Field replaceable
02311HAJFunction Module,Servers,SSD,1600GB,SAS 12Gb/s,Write Intensive,Sunset Cove Plus Series,2.5inch(2.5inch Drive Bay),ME Series EOP Field replaceable
0255Y194SSD Module,Servers,SSD,3200GB,NVMe PCIe,Mixed Use,UH830a-Y Series,2.5inch(2.5inch Drive Bay) Current Field replaceable
0255Y192SSD Module,Servers,SSD,1600GB,NVMe PCIe,Mixed Use,UH830a-Y Series,2.5inch(2.5inch Drive Bay) Current Field replaceable
0255Y182SSD Module,Servers,SSD,3840GB,NVMe PCIe,Read Intensive,UH810a-Y Series,2.5inch(2.5inch Drive Bay) Current Field replaceable
0255Y180SSD Module,Servers,SSD,1920GB,NVMe PCIe,Read Intensive,UH810a-Y Series,2.5inch(2.5inch Drive Bay) Current Field replaceable
02311XRXFunction Module,Servers,ES3620P V3 SSD,6400GB,NVMe PCIe,Mixed Use,3 DWPD,2.5inch(2.5inch Drive Bay),VE Series EOP Field replaceable
02312GNYFunction Module,Servers,SSD,3840GB,SATA 6Gb/s,Read Intensive,PM883 Series,2.5inch(2.5inch Drive Bay),IT Server Dedicated Current Field replaceable
02312BVEFunction Module,Servers,SSD,2000GB,NVMe PCIe,Read Intensive,P4510 series,2.5inch(2.5inch Drive Bay),LE Series,IT Server Dedicated Current Field replaceable
02312LKEFunction Module,Servers,SSD,3200GB,NVMe PCIe,P4610 Series,2.5inch(2.5inch Drive Bay),IT Server Dedicated Current Field replaceable
02312LKHFunction Module,Servers,SSD,960GB,NVMe PCIe,Read Intensive,PM983 series,2.5inch(2.5inch Drive Bay),IT Server Dedicated EOP Field replaceable
02312LKGFunction Module,Servers,SSD,1600GB,NVMe PCIe,P4610 Series,2.5inch(2.5inch Drive Bay),IT Server Dedicated Current Field replaceable
02312LKLFunction Module,Servers,SSD,3840GB,NVMe PCIe,Read Intensive,PM983 series,2.5inch(2.5inch Drive Bay),IT Server Dedicated EOP Field replaceable
02312LKKFunction Module,Servers,SSD,1920GB,NVMe PCIe,PM983 LE Series,2.5inch(2.5inch Drive Bay),IT Server Dedicated EOP Field replaceable
02312PJYFunction Module,Servers,ES3610P V5 SSD,3200GB,NVMe PCIe,Mixed Use,2.5inch(2.5inch Drive Bay) EOP Field replaceable
02312HBAFunction Module,Server,Hard Disk,300GB,SAS 12Gb/s,10000rpm,2.5inch,128MB or above,Hot_plug,Built-in,2.5 inch Front Panel,Only For Brazil EOP Field replaceable
02312HBCFunction Module,Server,Hard Disk,600GB,SAS 12Gb/s,10000rpm,2.5inch,128MB or above,Hot_plug,Built-in,2.5 inch Front Panel,Only For Brazil EOP Field replaceable
02312HBBFunction Module,Server,HardDisk-300GB-SAS 12Gb/s-15K rpm-128MB-2.5inch(2.5inch Drive Bay),Only For Brazil EOP Field replaceable
02312HBEFunction Module,Server,Hard Disk,1200GB,SAS 12Gb/s,10000rpm,2.5inch,128MB or above,Hot_plug,Built-in,2.5 inch Front Panel,Only For Brazil EOP Field replaceable
0255Y151SSD Module,Servers,SSD,6400GB,NVMe PCIe,Mixed Use,EP600 Series,2.5inch(2.5inch Drive Bay) Current Field replaceable
02312PBNFunction Module,Servers,SSD,3200GB,NVMe PCIe,PM1725b Series,2.5inch(2.5inch Drive Bay),IT Server Dedicated EOP Field replaceable
02312PBPFunction Module,Servers,P46106400GW2,SSD,6400GB,NVMe PCIe,P4610 Series,2.5inch(2.5inch Drive Bay),IT Server Dedicated Current Field replaceable
0255Y141SSD Module,Servers,SSD,1920GB,NVMe PCIe,Read Intensive,EP500 Series,2.5inch(2.5inch Drive Bay) Current Field replaceable
0255Y147SSD Module,Servers,SSD,1600GB,NVMe PCIe,Mixed Use,EP600 Series,2.5inch(2.5inch Drive Bay) Current Field replaceable
0255Y149SSD Module,Servers,SSD,3200GB,NVMe PCIe,Mixed Use,EP600 Series,2.5inch(2.5inch Drive Bay) Current Field replaceable
0255Y143SSD Module,Servers,SSD,3840GB,NVMe PCIe,Read Intensive,EP500 Series,2.5inch(2.5inch Drive Bay) Current Field replaceable
0255Y145SSD Module,Servers,SSD,7680GB,NVMe PCIe,Read Intensive,EP500 Series,2.5inch(2.5inch Drive Bay) Current Field replaceable
0255Y004SSD Module,Servers,SSD,3840GB,NVMe PCIe,Read Intensive,PM9A3 Series,2.5inch(2.5inch Drive Bay) Current Field replaceable
0255Y002SSD Module,Servers,SSD,1920GB,NVMe PCIe,Read Intensive,PM9A3 Series,2.5inch(2.5inch Drive Bay) Current Field replaceable
02312TBTFunction Module,Servers,PM1725B1600G2,SSD,1600GB,NVMe PCIe,Mixed Use,PM1725b series,2.5inch(2.5inch Drive Bay),IT Server Dedicated EOP Field replaceable
02312DEJFunction Module,Servers,HDD,12TB,NL SAS 12Gb/s,7.2K rpm,256MB,3.5inch(3.5inch Drive Bay) EOP Field replaceable
0255Y065SSD Module,Servers,SSD,7680GB,NVMe PCIe,Read Intensive,PM9A3 Series,2.5inch(2.5inch Drive Bay) Current Field replaceable
02312HPFFunction Module,Servers,HDD,14TB,NL SAS 12Gb/s,7.2K rpm,3.5inch(3.5inch Drive Bay) EOP Field replaceable
02312RCSFunction Module,Server,Hard Disk,600GB,SAS 12Gb/s,10000rpm,2.5inch,128MB or above,Hot_plug,Built-in,2.5 inch Front Panel,Only For Brazil EOP Field replaceable
02312RCUFunction Module,Server,Hard Disk,1200GB,SAS 12Gb/s,10000rpm,2.5inch,128MB or above,Hot_plug,Built-in,2.5 inch Front Panel,Only For Brazil EOP Field replaceable
02312RCWFunction Module,Server,Hard Disk,1800GB,SAS 12Gb/s,10000rpm,2.5inch,128MB,Hot-swap,Built-in,2.5inch Front Panel,For Brazil Only EOP Field replaceable
02312HQTFunction Module,Server,HDD,1000GB,SATA,7.2K rpm,2.5",64MB,Hot-swap,Built-in,2.5inch Front Panel,For Brazil Only EOP Field replaceable
02312HQUFunction Module,Server,Hard Disk,1800GB,SAS 12Gb/s,10000rpm,2.5inch,128MB,Hot-swap,Built-in,2.5inch Front Panel,For Brazil Only EOP Field replaceable
02550257SSD Module,Servers,ES3521A V6,HW SSD,Disk Unit,480GB SATA 6Gb/s,Read intensive,2.5inch(2.5inch Drive Bay) EOP Field replaceable
02550258SSD Module,Servers,ES3521A V6,HW SSD,Disk Unit,960GB SATA 6Gb/s,Read intensive,2.5inch(2.5inch Drive Bay) EOP Field replaceable
02312HRBFunction Module,Server,Hard Disk,1000GB,NL SAS 12Gb/s,7.2K rpm,128MB,2.5 inch(2.5inch Drive Bay),For Brazil Only EOP Field replaceable
02312HRGFunction Module,Servers,SSD,480GB,SATA 6Gb/s,Read Intensive,CloudSpeed2 Series,2.5inch(2.5inch Drive Bay),LE Series,For Brazil Only EOP Field replaceable
02312HRQFunction Module,Server,Hard Disk,2000GB,SATA 6Gb/s,7.2K rpm,128MB,2.5inch(2.5 inch Drive Bay),For Brazil Only EOP Field replaceable
02312HRSFunction Module,Server,Hard Disk,2000GB,NL SAS 12Gb/s,7.2K rpm,128MB,2.5inch(2.5inch Drive Bay),For Brazil Only EOP Field replaceable
02312HRVFunction Module,Server,HardDisk,600GB,SAS 12Gb/s,15K rpm,128MB,2.5inch(2.5inch Drive Bay),For Brazil Only EOP Field replaceable
02550261SSD Module,Servers,ES3521A V6,HW SSD,Disk Unit,1920GB SATA 6Gb/s,Read intensive,2.5inch(2.5inch Drive Bay) EOP Field replaceable
02312PJXFunction Module,Servers,ES3510P V5 SSD,8000GB,NVMe PCIe,Read Intensive,2.5inch(2.5inch Drive Bay) EOP Field replaceable
02312QMNFunction Module,Servers,ES3510P V5 SSD,4000GB,NVMe PCIe,Read-intensive,2.5inch(2.5inch Drive Bay),Supply continuity EOP Field replaceable
02312QMPFunction Module,Servers,ES3510P,ES3510P V5 SSD,7680GB,NVMe PCIe,Read-intensive,2.5inch(2.5inch Drive Bay),Supply continuity EOP Field replaceable
02312TKWFunction Module,Servers,ES3510P2000GW2,ES3510P V5 SSD,2000GB,NVMe PCIe,Read-intensive,2.5inch(2.5inch Drive Bay),Supply continuity EOP Field replaceable
02312TKYFunction Module,Servers,ES3610P1600GW2,ES3610P V5 SSD,1600GB,NVMe PCIe,Mixed Use,2.5inch(2.5inch Drive Bay),Supply continuity EOP Field replaceable
02312REWFunction Module,Servers,ES3610P V5,ES3610P V5 SSD,6400GB,NVMe PCIe,Mixed Use,2.5inch(2.5inch Drive Bay),Supply continuity EOP Field replaceable
02312RCRFunction Module,Server,Hard Disk,300GB,SAS 12Gb/s,10000rpm,2.5inch,128MB or above,Hot_plug,Built-in,2.5 inch Front Panel,Only For Brazil EOP Field replaceable
P/NDescription / SpecificationStatus
0255Y002SSD module-Servers-SSD-1920GB-NVMe PCIe-read-intensive-PM9A3 series-2.5 inch(2.5 inch bracket) Current
0255Y004SSD module-Servers-SSD-3840GB-NVMe PCIe-read-intensive-PM9A3 series-2.5 inch(2.5 inch bracket) Current
0255Y065SSD module-Servers-SSD-7680GB-NVMe PCIe-read-intensive-PM9A3 series-2.5 inch(2.5 inch bracket) Current
0255Y648SSD module-Servers-SSD-1920GB-NVMe PCIe-read-intensive-EP500 series-2.5 inch(2.5 inch bracket)-global Current
0255Y650SSD module-Servers-SSD-3840GB-NVMe PCIe-read-intensive-EP500 series-2.5 inch(2.5 inch bracket)-global Current
0255Y652SSD module-Servers-SSD-1600GB-NVMe PCIe-mixed read-write-EP600 series-2.5 inch(2.5 inch bracket)-global Current
0255Y656SSD module-Servers-SSD-6400GB-NVMe PCIe-mixed read-write-EP600 series-2.5 inch(2.5 inch bracket)-global Current
0255YFCWSSD module-Servers-SSD-7680GB-NVMe PCIe-read-intensive-PM9A3 series-2.5 inch(2.5 inch bracket) Current
0255YFDLSSD module-Servers-SSD-1920GB-NVMe PCIe-read-intensive-PM9A3 series-2.5 inch(2.5 inch bracket) Current
0255YFDTSSD module-Servers-SSD-3840GB-NVMe PCIe-read-intensive-PM9A3 series-2.5 inch(2.5 inch bracket) Current
02311MRNfunction module-Servers-ES3600P V3 SSD-3200GB-NVMe PCIe-mixed read-write-3 DWPD-2.5 inch(2.5 inch bracket) EOS
02311MRXfunction module-Servers-ES3600P V3 SSD-1200GB-NVMe PCIe-mixed read-write-3 DWPD-2.5 inch(2.5 inch bracket) EOS
02311MSAfunction module-Servers-ES3600P V3 SSD-1600GB-NVMe PCIe-mixed read-write-3 DWPD-2.5 inch(2.5 inch bracket) EOS
02311MSCfunction module-Servers-ES3500P V3 SSD-2000GB-NVMe PCIe-read-intensive-1 DWPD-2.5 inch(2.5 inch bracket) EOS
02311MSEfunction module-Servers-ES3500P V3 SSD-3200GB-NVMe PCIe-read-intensive-1 DWPD-2.5 inch(2.5 inch bracket) EOS
02311NUDfunction module-Servers-ES3500P V3 SSD-1200GB-NVMe PCIe-read-intensive-2.5 inch(2.5 inch bracket)-LE series EOS
02311SCPfunction module-Servers-ES3600P V3 SSD-2000GB-NVMe PCIe-mixed read-write-3 DWPD-2.5 inch(2.5 inch bracket) EOS
02311UFMfunction module-Servers-ES3600P V3 SSD-800GB-NVMe PCIe-mixed read-write-3 DWPD-2.5 inch(2.5 inch bracket)-VE series EOS
02311UGCfunction module-Servers-ES3500P V3 SSD-800GB-NVMe PCIe-read-intensive-2.5 inch(2.5 inch bracket)-LE series EOS
02311XRXfunction module-Servers-ES3620P V3 SSD-6400GB-NVMe PCIe-mixed read-write-3 DWPD-2.5 inch(2.5 inch bracket)-VE series EOS
02311YBRfunction module-Servers-ES3500P V3 SSD-4000GB-NVMe PCIe-read-intensive-0.3 DWPD-2.5 inch(2.5 inch bracket)-LE series EOS
02312BVEfunction module-Servers-SSD-2000GB-NVMe PCIe-read-intensive-P4510 series-2.5 inch(2.5 inch bracket)-LE series-IT product-line server dedicated EOP
02312DBHfunction module-Servers-SSD-1000GB-NVMe PCIe-read-intensive-P4510 series-2.5 inch(2.5 inch bracket)-LE series-IT product-line server dedicated EOP
02312DBTfunction module-Servers-SSD-4000GB-NVMe PCIe-read-intensive-P4510 series-2.5 inch(2.5 inch bracket)-LE series-IT product-line server dedicated EOM
02312FPRfunction module-Servers-ES3500P V5 SSD-1000GB-NVMe PCIe-read-intensive-2.5 inch(2.5 inch bracket) EOP
02312FPXfunction module-Servers-ES3500P V5 SSD-2000GB-NVMe PCIe-read-intensive-2.5 inch(2.5 inch bracket) EOP
02312FQBfunction module-Servers-ES3500P V5 SSD-4000GB-NVMe PCIe-read-intensive-2.5 inch(2.5 inch bracket) EOP
02312FQDfunction module-Servers-ES3500P V5 SSD-8000GB-NVMe PCIe-read-intensive-2.5 inch(2.5 inch bracket) EOP
02312FQSfunction module-Servers-ES3600P V5 SSD-800GB-NVMe PCIe-mixed read-write-2.5 inch(2.5 inch bracket) EOP
02312FQVfunction module-Servers-ES3600P V5 SSD-1600GB-NVMe PCIe-mixed read-write-2.5 inch(2.5 inch bracket) EOP
02312FQWfunction module-Servers-ES3600P V5 SSD-3200GB-NVMe PCIe-mixed read-write-2.5 inch(2.5 inch bracket) EOP
02312FRAfunction module-Servers-ES3600P V5 SSD-6400GB-NVMe PCIe-mixed read-write-2.5 inch(2.5 inch bracket) EOP
02312HESfunction module-Servers-SSD-8000GB-NVMe PCIe-read-intensive-P4510 series-2.5 inch(2.5 inch bracket)-IT product-line server dedicated EOM
02312LKEfunction module-Servers-SSD-3200GB-NVMe PCIe-P4610 series-2.5 inch(2.5 inch bracket)-IT product-line server dedicated EOP
02312LKGfunction module-Servers-SSD-1600GB-NVMe PCIe-P4610 series-2.5 inch(2.5 inch bracket)-IT product-line server dedicated EOM
02312LKHfunction module-Servers-SSD-960GB-NVMe PCIe-read-intensive-PM983 series-2.5 inch(2.5 inch bracket)-IT product-line server dedicated EOP
02312LKKfunction module-Servers-SSD-1920GB-NVMe PCIe-PM983 LE series-2.5 inch(2.5 inch bracket)-IT product-line server dedicated EOP
02312LKLfunction module-Servers-SSD-3840GB-NVMe PCIe-read-intensive-PM983 series-2.5 inch(2.5 inch bracket)-IT product-line server dedicated EOM
02312PBNfunction module-Servers-SSD-3200GB-NVMe PCIe-PM1725b series-2.5 inch(2.5 inch bracket)-IT product-line server dedicated EOP
02312PBPfunction module-Servers-P46106400GW2-SSD-6400GB-NVMe PCIe-P4610 series-2.5 inch(2.5 inch bracket)-IT product-line server dedicated EOP
02312PJXfunction module-Servers-ES3510P V5 SSD-8000GB-NVMe PCIe-read-intensive-2.5 inch(2.5 inch bracket) EOP
02312PJYfunction module-Servers-ES3610P V5 SSD-3200GB-NVMe PCIe-mixed read-write-2.5 inch(2.5 inch bracket) EOP
02312QMNfunction module-Servers-ES3510P V5 SSD-4000GB-NVMe PCIe-read-intensive-2.5 inch(2.5 inch bracket)-supply continuity EOP
02312QMPfunction module-Servers-ES3510P V5 SSD-7680GB-NVMe PCIe-read-intensive-2.5 inch(2.5 inch bracket)-supply continuity EOP
02312REWfunction module-Servers-ES3610P V5 SSD-6400GB-NVMe PCIe-mixed read-write-2.5 inch(2.5 inch bracket)-supply continuity EOP
02312TBLfunction module-Servers-SSD-1920GB-NVMe PCIe-read-intensive-PM1733 series-2.5 inch(2.5 inch bracket)-IT product-line server dedicated EOP
02312TBNfunction module-Servers-SSD-3840GB-NVMe PCIe-read-intensive-PM1733 series-2.5 inch(2.5 inch bracket)-IT product-line server dedicated EOP
02312TBTfunction module-Servers-PM1725B1600G2-SSD-1600GB-NVMe PCIe-mixed read-write-PM1725b series-2.5 inch(2.5 inch bracket)-IT product-line server dedicated EOM
02312TKWfunction module-Servers-ES3510P2000GW2-ES3510P V5 SSD-2000GB-NVMe PCIe-read-intensive-2.5 inch(2.5 inch bracket)-supply continuity EOP
02312TKYfunction module-Servers-ES3610P1600GW2-ES3610P V5 SSD-1600GB-NVMe PCIe-mixed read-write-2.5 inch(2.5 inch bracket)-supply continuity EOP
02313FTCfunction module-Servers-SSD-7680GB-NVMe PCIe-read-intensive-PM1733 series-2.5 inch(2.5 inch bracket) EOP
0255Y031SSD module-Servers-SSD-7680GB-NVMe PCIe-read-intensive-UH810a-K series-2.5 inch(2.5 inch bracket) EOM
0255Y134SSD module-Servers-SSD-6400GB-NVMe PCIe-mixed read-write-UH830a-K series-2.5 inch(2.5 inch bracket) EOM
0255Y135SSD module-Servers-SSD-3200GB-NVMe PCIe-mixed read-write-UH831a-Y series-2.5 inch(2.5 inch bracket) EOM
0255Y141SSD module-Servers-SSD-1920GB-NVMe PCIe-read-intensive-EP500 series-2.5 inch(2.5 inch bracket) EOM
0255Y143SSD module-Servers-SSD-3840GB-NVMe PCIe-read-intensive-EP500 series-2.5 inch(2.5 inch bracket) EOM
0255Y145SSD module-Servers-SSD-7680GB-NVMe PCIe-read-intensive-EP500 series-2.5 inch(2.5 inch bracket) EOM
0255Y147SSD module-Servers-SSD-1600GB-NVMe PCIe-mixed read-write-EP600 series-2.5 inch(2.5 inch bracket) EOM
0255Y149SSD module-Servers-SSD-3200GB-NVMe PCIe-mixed read-write-EP600 series-2.5 inch(2.5 inch bracket) EOM
0255Y151SSD module-Servers-SSD-6400GB-NVMe PCIe-mixed read-write-EP600 series-2.5 inch(2.5 inch bracket) EOM
0255Y180SSD module-Servers-SSD-1920GB-NVMe PCIe-read-intensive-UH810a-Y series-2.5 inch(2.5 inch bracket) EOP
0255Y182SSD module-Servers-SSD-3840GB-NVMe PCIe-read-intensive-UH810a-Y series-2.5 inch(2.5 inch bracket) EOP
0255Y192SSD module-Servers-SSD-1600GB-NVMe PCIe-mixed read-write-UH830a-Y series-2.5 inch(2.5 inch bracket) EOP
0255Y194SSD module-Servers-SSD-3200GB-NVMe PCIe-mixed read-write-UH830a-Y series-2.5 inch(2.5 inch bracket) EOM
0255Y213SSD module-Servers-SSD-3840GB-NVMe PCIe-read-intensive-UH811a-Y series-2.5 inch(2.5 inch bracket) EOM
0255Y646SSD module-Servers-SSD-7680GB-NVMe PCIe-read-intensive-EP500 series-2.5 inch(2.5 inch bracket)-global EOM
0255Y654SSD module-Servers-SSD-3200GB-NVMe PCIe-mixed read-write-EP600 series-2.5 inch(2.5 inch bracket)-global EOM
02312EKXFunction Module,Public Module,BC1M04M2FRU,M.2 SSD,SATA 6Gb/s-240GB,80.0mm * 22.0mm * 3.58 mm(Hot-Swappable) EOP Field replaceable
02312ACWFunction Module,Public Module,BC1M01M2FRU,M.2 SSD,SATA 6Gb/s-240GB,80.0mm * 22.0mm * 3.58 mm(Hot-Swappable) EOP Field replaceable
02312BLQFunction Module,Public Module,BC1M02M2FRU,M.2 SSD,SATA 6Gb/s-32GB,22mm*42mm(Hot-Swappable) EOP Field replaceable
02311PBKFunction Module,ES3000 V3,CN2M10FACM,ES3600C-1600GB-3 DWPD-PCIE 3.0 X4-Vendor ID 19e5-Device ID 0123-1,Model number HWE36P43016M000N,HH/HL Card,NVMe SSD EOP Field replaceable
0255Y697SSD Module,Servers,M.2 SSD,SATA 6Gb/s-480GB,80.0mm * 22.0mm * 3.58 mm(hot-swappable),ER3 series Current Field replaceable
02311SNLFunction Module,ES3000 V3,CN2M10FAMS,ES3620C-6400GB-3 DWPD-PCIE 3.0 X4-Vendor ID 19e5-Device ID 0123-1,Model number HWE36P43064M001N,HH/HL Card,NVMe SSD EOP Field replaceable
02311PEMFunction Module,ES3000 V3,CN2M10FACL,ES3600C-1200GB-3 DWPD-PCIE 3.0 X4-Vendor ID 19e5-Device ID 0123-1,Model number HWE36P43012M000N,HH/HL Card,NVMe SSD EOP Field replaceable
02311PBJFunction Module,ES3000 V3,CN2M10FACP,ES3600C-3200GB-3 DWPD-PCIE 3.0 X4-Vendor ID 19e5-Device ID 0123-1,Model number HWE36P43032M000N,HH/HL Card,NVMe SSD EOP Field replaceable
02311SHAFunction Module,ES3000 V3,HWE36P43008M000N,ES3600C-800GB-3 DWPD-PCIE 3.0 X4-Vendor ID 19e5-Device ID 0123-1,Model number HWE36P43008M000N,HH/HL Card,NVMe SSD EOP Field replaceable
02312JRTFunction Module,ES3000 V5,CN2M20PWBD,ES3600C-800GB-3 DWPD-PCIE 3.0 X4-Vendor ID 19e5-Device ID 3714-1,Model number HWE56P43800M002N,HH/HL Card,NVMe SSD EOP Field replaceable
02312JRWFunction Module,ES3000 V5,CN2M22PWBB,ES3600C-3200GB-3 DWPD-PCIE 3.0 X4-Vendor ID 19e5-Device ID 3714-1,Model number HWE56P433T2M002N,HH/HL Card,NVMe SSD EOP Field replaceable
02312JRVFunction Module,ES3000 V5,CN2M21PWBA,ES3600C-1600GB-3 DWPD-PCIE 3.0 X4-Vendor ID 19e5-Device ID 3714-1,Model number HWE56P431T6M002N,HH/HL Card,NVMe SSD EOP Field replaceable
02312JRXFunction Module,ES3000 V5,CN2M23PMBC,ES3600C-6400GB-3 DWPD-PCIE 3.0 X4-Vendor ID 19e5-Device ID 3714-1,Model number HWE56P436T4M002N,HH/HL Card,NVMe SSD EOP Field replaceable
0255Y695SSD Module,Servers,M.2 SSD,SATA 6Gb/s-240GB,80.0mm * 22.0mm * 3.58 mm(hot-swappable),ER3 series Current Field replaceable
02313ARHFunction Module,Public Module,M.2 SSD,SATA 6Gb/s-480GB,80.0mm * 22.0mm * 3.58 mm(Hot-Swappable) Current Field replaceable
02312LKBFunction Module,Public Module,BC1M08M2FRU,M.2 SSD-240GB SATA 6Gb/s-80.0mm * 22.0mm * 3.58 mm(Hot-Swappable) EOP Field replaceable
02312MCFFunction Module,Public Module,BC1M09M2FRU,M.2 SSD,SATA 6Gb/s-480GB,80.0mm * 22.0mm * 3.58 mm(Hot-Swappable) EOP Field replaceable
02312XKGFunction Module,Public Module,ER2GD480GM2,M.2 SSD,SATA 6Gb/s-480GB,80.0mm * 22.0mm * 3.58 mm(Hot-Swappable) EOP Field replaceable
02312TADFunction Module,Server,ES3610C800GFH,ES3610C-800GB-3 DWPD-PCIE 3.0 X4-Vendor ID 19e5-Device ID 3714-1,Model number HWE56P43800M005N,HH/HL Card Full-height packing code,NVMe SSD EOP Field replaceable
02312KGRFunction Module,Public Module,BC1M07M2FRU,M.2 SSD-SATA 6Gb/s-64GB-M.2-B-M-2242-22mm*42mm(Hot-Swappable) Current Field replaceable
02312TAFFunction Module,Server,ES3610C1600GFH,ES3610C-1600GB-3 DWPD-PCIE 3.0 X4-Vendor ID 19e5-Device ID 3714-1,Model number HWE56P431T6M005N,HH/HL Card Full-height packing code,NVMe SSD EOP Field replaceable
02312TAHFunction Module,Server,ES3610C3200GFH,ES3610C-3200GB-3 DWPD-PCIE 3.0 X4-Vendor ID 19e5-Device ID 3714-1,Model number HWE56P433T2M005N,HH/HL Card Full-height packing code,NVMe SSD EOP Field replaceable
02312TAKFunction Module,Server,ES3610C6400GFH,ES3610C-6400GB-3 DWPD-PCIE 3.0 X4-Vendor ID 19e5-Device ID 3714-1,Model number HWE56P436T4M005N,HH/HL Card Full-height packing code,NVMe SSD EOP Field replaceable
02312XGPFunction Module,Public Module,ER2GD240GM2,M.2 SSD,SATA 6Gb/s-240GB,80.0mm * 22.0mm * 3.58 mm(Hot-Swappable) EOP Field replaceable
02313ARCFunction Module,Public Module,M.2 SSD,SATA 6Gb/s-240GB,80.0mm * 22.0mm * 3.58 mm(Hot-Swappable) Current Field replaceable
02313EKDFunction Module,Public Module,M.2 SSD,SATA 6Gb/s-64GB,M.2-B-M-2242-22mm*42mm(Hot-Swappable) Current Field replaceable
02311YHCFunction Module,2488H V5,BC6M02NVME,NVMe interface module(support 4NVMe HDDs) used for SLOT5 EOP Engineer replace
02312EQGFunction Module,2488H V5,BC6M07NVME,NVMe interface module(support 4NVMe HDDs) used for 24NVME SLOT5 EOP Engineer replace
02312EQHFunction Module,2488H V5,BC6M08NVME,NVMe interface module(support 4NVMe HDDs) used for 24NVME SLOT10 EOP Engineer replace
02311YJQFunction Module,2488H V5,BC6M03NVME,NVMe interface module(support 4NVMe HDDs) used for SLOT10 EOP Engineer replace
P/NDescription / SpecificationStatus
02311YHLfunction module-2488H V5-BC6M05RAID-AVAGO9361 PCIe RAID standardcard-RAID0,1,5,6,10,50,60-1GB cache-PCIe 3.0 X8-applicable 8 drive model EOP
02311YHMfunction module-2488H V5-BC6M06RAID-AVAGO9361 PCIe RAID standardcard-RAID0,1,5,6,10,50,60-1GB cache-PCIe 3.0 X8-applicable 25 drive model EOP
02311YHNfunction module-2488H V5-BC6M07RAID-AVAGO9361 PCIe RAID standardcard-RAID0,1,5,6,10,50,60-1GB cache-PCIe 3.0 X8-applicable 8NVME+16HDD EOP
02311YHPfunction module-2488H V5-BC6M08RAID-AVAGO9361 PCIe RAID standardcard-RAID0,1,5,6,10,50,60-1GB cache-PCIe 3.0 X8-applicable 24 drive model SLOT4 EOP
02311YHTfunction module-2488H V5-BC6M09RAID-AVAGO9361 PCIe RAID standardcard-RAID0,1,5,6,10,50,60-1GB cache-PCIe 3.0 X8-applicable 24 drive model SLOT6 EOP
02311YHUfunction module-2488H V5-BC6M10RAID-AVAGO9361 PCIe RAID standardcard-RAID0,1,5,6,10,50,60-1GB cache-PCIe 3.0 X8-applicable 24 drive model SLOT8 EOP
02311YHVfunction module-2488H V5-BC6M11RAID-SP450C-M 2G(AVAGO3508)SAS/SATA RAID standardcard-RAID0,1,5,6,10,50,60-12Gb/s-2GB Cache-applicable 8 drive model EOP
02311YHWfunction module-2488H V5-BC6M40RAID-SP450C-M 2G(AVAGO3508)SAS/SATA RAID standardcard-RAID0,1,5,6,10,50,60-12Gb/s-2GB Cache-applicable 25 drive model EOP
02311YHXfunction module-2488H V5-BC6M19RAID-SP450C-M 2G(AVAGO3508)SAS/SATA RAID standardcard-RAID0,1,5,6,10,50,60-12Gb/s-2GB Cache-applicable 8NVME+16HDD EOP
02311YHYfunction module-2488H V5-BC6M14RAID-SP450C-M 2G(AVAGO3508)SAS/SATA RAID standardcard-RAID0,1,5,6,10,50,60-12Gb/s-2GB Cache-applicable 24 drive model SLOT4 EOP
02311YJAfunction module-2488H V5-BC6M15RAID-SP450C-M 2G(AVAGO3508)SAS/SATA RAID standardcard-RAID0,1,5,6,10,50,60-12Gb/s-2GB Cache-applicable 24 drive model SLOT6 EOP
02311YJBfunction module-2488H V5-BC6M16RAID-SP450C-M 2G(AVAGO3508)SAS/SATA RAID standardcard-RAID0,1,5,6,10,50,60-12Gb/s-2GB Cache-applicable 24 drive model SLOT8 EOP
02312BECfunction module-SR230-M-BC1M02MSMA-M.2-RAID standardcard-RAID0,1,JBOD-No Cach-supports sideband management-half-height half-length EOP
02312CBPfunction module-2488H V5-BC6M41RAID-SP450C-M 4G(AVAGO3508)SAS/SATA RAID standardcard-RAID0,1,5,6,10,50,60-12Gb/s-4GB Cache-applicable 8 drive model EOP
02312CBQfunction module-2488H V5-BC6M42RAID-SP450C-M 4G(AVAGO3508)SAS/SATA RAID standardcard-RAID0,1,5,6,10,50,60-12Gb/s-4GB Cache-applicable 8NVME+16HDD EOP
02312CBRfunction module-2488H V5-BC6M43RAID-SP450C-M 4G(AVAGO3508)SAS/SATA RAID standardcard-RAID0,1,5,6,10,50,60-12Gb/s-4GB Cache-applicable 24 drive model SLOT4 EOP
02312CBSfunction module-2488H V5-BC6M44RAID-SP450C-M 4G(AVAGO3508)SAS/SATA RAID standardcard-RAID0,1,5,6,10,50,60-12Gb/s-4GB Cache-applicable 24 drive model SLOT6 EOP
02312CBTfunction module-2488H V5-BC6M45RAID-SP450C-M 4G(AVAGO3508)SAS/SATA RAID standardcard-RAID0,1,5,6,10,50,60-12Gb/s-4GB Cache-applicable 24 drive model SLOT8 EOP
02312CBUfunction module-2488H V5-BC6M46RAID-SP450C-M 4G(AVAGO3508)SAS/SATA RAID standardcard-RAID0,1,5,6,10,50,60-12Gb/s-4GB Cache-applicable 25 drive model EOP
02312CCAfunction module-2488H V5-BC6M47RAID-SP150-M(AVAGO3408)SAS/SATA RAID standardcard-RAID0,1,10-12Gb/s-0 Cache-applicable 8 drive model EOP
02312CCHfunction module-2488H V5-BC6M48RAID-SP150-M(AVAGO3408)SAS/SATA RAID standardcard-RAID0,1,10-12Gb/s-0 Cache-applicable 8NVME+16HDD EOP
02312CCJfunction module-2488H V5-BC6M49RAID-SP150-M(AVAGO3408)SAS/SATA RAID standardcard-RAID0,1,10-12Gb/s-0 Cache-applicable 24 drive model SLOT4 EOP
02312CCKfunction module-2488H V5-BC6M50RAID-SP150-M(AVAGO3408)SAS/SATA RAID standardcard-RAID0,1,10-12Gb/s-0 Cache-applicable 24 drive model SLOT6 EOP
02312CCLfunction module-2488H V5-BC6M51RAID-SP150-M(AVAGO3408)SAS/SATA RAID standardcard-RAID0,1,10-12Gb/s-0 Cache-applicable 24 drive model SLOT8 EOP
02312CCMfunction module-2488H V5-BC6M52RAID-SP150-M(AVAGO3408)SAS/SATA RAID standardcard-RAID0,1,10-12Gb/s-0 Cache-applicable 25 drive model EOP
02312DUAfunction module-2488H V5-BC6M56RAID-AVAGO9361 PCIe RAID standardcard-Cachecade Key-RAID0,1,5,6,10,50,60-1GB cache-PCIe 3.0 X8-applicable 8 drive model EOP
02312DUBfunction module-2488H V5-BC6M57RAID-AVAGO9361 PCIe RAID standardcard-Cachecade Key-RAID0,1,5,6,10,50,60-1GB cache-PCIe 3.0 X8-applicable 25 drive model EOP
02312DUEfunction module-2488H V5-BC6M58RAID-AVAGO9361 PCIe RAID standardcard-Cachecade Key-RAID0,1,5,6,10,50,60-1GB cache-PCIe 3.0 X8-applicable 8NVME+16HDD EOP
02312DUHfunction module-2488H V5-BC6M59RAID-AVAGO9361 PCIe RAID standardcard-Cachecade Key-RAID0,1,5,6,10,50,60-1GB cache-PCIe 3.0 X8-applicable 24 drive model SLOT4 EOP
02312DUJfunction module-2488H V5-BC6M62RAID-AVAGO9361 PCIe RAID standardcard-Cachecade Key-RAID0,1,5,6,10,50,60-1GB cache-PCIe 3.0 X8-applicable 24 drive model SLOT6 EOP
02312DUKfunction module-2488H V5-BC6M61RAID-AVAGO9361 PCIe RAID standardcard-Cachecade Key-RAID0,1,5,6,10,50,60-1GB cache-PCIe 3.0 X8-applicable 24 drive model SLOT8 EOP
02312HKDfunction module-2488H V5-BC6M88RAID-SP450C-M 2G(AVAGO3508)SAS/SATA RAID standardcard-RAID0,1,5,6,10,50,60-12Gb/s-2GB Cache-applicable 24NVMe model EOP
02312KTEfunction module-2488H V5-BC6M95RAID-SmartRAID 3152-8i RAID standardcard-RAID 0,1,5,6,10,50,60,1/10ADM-2GB cache-PCIE 3.0 X8-applicable 8 drive model EOP
02312KTFfunction module-2488H V5-BC6M96RAID-SmartRAID 3152-8i RAID standardcard-RAID 0,1,5,6,10,50,60,1/10ADM-2GB cache-PCIE 3.0 X8-applicable 25 drive model EOP
02312KTGfunction module-2488H V5-BC6M97RAID-SmartRAID 3152-8i RAID standardcard-RAID 0,1,5,6,10,50,60,1/10ADM-2GB cache-PCIE 3.0 X8-applicable 8NVME+16HDD EOP
02312KTHfunction module-2488H V5-BC6M98RAID-SmartRAID 3152-8i RAID standardcard-RAID 0,1,5,6,10,50,60,1/10ADM-2GB cache-PCIE 3.0 X8-applicable 24 drive model SLOT4 EOP
02312KTJfunction module-2488H V5-BC6M99RAID-SmartRAID 3152-8i RAID standardcard-RAID 0,1,5,6,10,50,60,1/10ADM-2GB cache-PCIE 3.0 X8-applicable 24 drive model SLOT6 EOP
02312KTKfunction module-2488H V5-BC7M01RAID-SmartRAID 3152-8i RAID standardcard-RAID 0,1,5,6,10,50,60,1/10ADM-2GB cache-PCIE 3.0 X8-applicable 24 drive model SLOT8 EOP
02312KTLfunction module-2488H V5-BC7M02RAID-SmartHBA 2100-8i RAID standardcard-RAID 0,1,5,10-no cache-PCIE 3.0 X8-applicable 8 drive model EOP
02312KTMfunction module-2488H V5-BC7M03RAID-SmartHBA 2100-8i RAID standardcard-RAID 0,1,5,10-no cache-PCIE 3.0 X8-applicable 25 drive model EOP
02312KTNfunction module-2488H V5-BC7M04RAID-SmartHBA 2100-8i RAID standardcard-RAID 0,1,5,10-no cache-PCIE 3.0 X8-applicable 8NVME+16HDD EOP
02312KTQfunction module-2488H V5-BC7M05RAID-SmartHBA 2100-8i RAID standardcard-RAID 0,1,5,10-no cache-PCIE 3.0 X8-applicable 24 drive model SLOT4 EOP
02312KTSfunction module-2488H V5-BC7M06RAID-SmartHBA 2100-8i RAID standardcard-RAID 0,1,5,10-no cache-PCIE 3.0 X8-applicable 24 drive model SLOT6 EOP
02312KTTfunction module-2488H V5-BC7M07RAID-SmartHBA 2100-8i RAID standardcard-RAID 0,1,5,10-no cache-PCIE 3.0 X8-applicable 24 drive model SLOT8 EOP
02312RJGfunction module-2488H V5-BC7M08RAID-9460-8i 2G other board card-12G SAS RAID card-RAID0,1,5,6,10,50,60-2G cache-8*12Gb/s SAS PHY-2 miniSAS HD internal interface-applicable 8 drive model EOP
02312RJHfunction module-2488H V5-BC7M09RAID-9460-8i 2G other board card-12G SAS RAID card-RAID0,1,5,6,10,50,60-2G cache-8*12Gb/s SAS PHY-2 miniSAS HD internal interface-applicable 25 drive model EOP
02312SWWfunction module-2488H V5-BC8M01RAID-9460-8i 4G other board card-12G SAS RAID card-RAID0,1,5,6,10,50,60-4G cache-8*12Gb/s SAS PHY-2 miniSAS HD internal interface-applicable 8 drive model EOP
02312SWYfunction module-2488H V5-BC8M02RAID-9460-8i 4G other board card-12G SAS RAID card-RAID0,1,5,6,10,50,60-4G cache-8*12Gb/s SAS PHY-2 miniSAS HD internal interface-applicable 25 drive model EOP
02313CAYfunction module-2488H V5-BC8M11RAID-9440-8i 0G other board card-12G SAS RAID card-RAID0,1,10-no cache-8*12Gb/s SAS PHY-2 miniSAS HD internal interface-applicable 8 drive model EOP
02313CBDfunction module-2488H V5-BC8M12RAID-9440-8i 0G other board card-12G SAS RAID card-RAID0,1,10-no cache-8*12Gb/s SAS PHY-2 miniSAS HD internal interface-applicable 25 drive model EOP
0231Y348function module-Public Module-BC1M04MSMA-XR230-M M.2-RAID standardcard-RAID0,1,JBOD-No Cach-supports sideband management-half-height half-length EOP
0231Y388function module-Public Module-CN2M01RLCAA1-XP450C-M 4G-PCIe RAID standardcard-RAID0,1,5,6,10,50,60-4GB Cache(Avago3508)-PCIe 3.0 x8-full-height half-length-PCIE 3.0 X8-Vendor ID 1000-Device ID 0016-Subvendor ID 1F24-Subdevice ID D215 EOP
0231Y514function module-2488H V5-BC8M03RAID-9460-8i 4G other board card-12G SAS RAID card-RAID0,1,5,6,10,50,60-4G cache-8*12Gb/s SAS PHY-2 miniSAS HD internal interface-applicable 8NVME+16HDD EOP
0231Y705function module-2488H V5-BC7M20RAID-9560-8i 4G other board card-12G SAS RAID card-4G cache-8*12Gb/s SAS PHY-1 slimline internal interface--applicable 8 drive model EOP
0231Y774function module-2488H V5-CN2M05RLNA1-XP150-M(AVAGO3408)SAS/SATA RAID standardcard-RAID0,1,10-12Gb/s-0 Cache-applicable 8 drive model EOP
0231Y775function module-2488H V5-CN2M06RLNA1-XP150-M(AVAGO3408)SAS/SATA RAID standardcard-RAID0,1,10-12Gb/s-0 Cache-applicable 8NVME+16HDD EOP
0231Y776function module-2488H V5-CN2M07RLNA1-XP150-M(AVAGO3408)SAS/SATA RAID standardcard-RAID0,1,10-12Gb/s-0 Cache-applicable 24 drive model SLOT4 EOP
0231Y777function module-2488H V5-CN2M08RLNA1-XP150-M(AVAGO3408)SAS/SATA RAID standardcard-RAID0,1,10-12Gb/s-0 Cache-applicable 24 drive model SLOT6 EOP
0231Y778function module-2488H V5-CN2M09RLNA1-XP150-M(AVAGO3408)SAS/SATA RAID standardcard-RAID0,1,10-12Gb/s-0 Cache-applicable 24 drive model SLOT8 EOP
0231Y779function module-2488H V5-CN2M10RLNA1-XP150-M(AVAGO3408)SAS/SATA RAID standardcard-RAID0,1,10-12Gb/s-0 Cache-applicable 25 drive model EOP
0231Y962function module-2488H V5-BC7M22RAID-9560-16i 8G other board card-12 SAS RAID card-8G cache-16*12Gb/s SAS PHY-2 slimline internal interface--applicable 8 drive model EOP
0231YAGVfunction module-2488H V5-CN2M12RLCA1-XP450C-M 2G(AVAGO3508)SAS/SATA RAID standardcard-RAID0,1,5,6,10,50,60-12Gb/s-2GB Cache-applicable 8 drive model EOP
0231YAGWfunction module-2488H V5-CN2M13RLCA1-XP450C-M 2G(AVAGO3508)SAS/SATA RAID standardcard-RAID0,1,5,6,10,50,60-12Gb/s-2GB Cache-applicable 8NVME+16HDD EOP
0231YAGXfunction module-2488H V5-CN2M14RLCA1-XP450C-M 2G(AVAGO3508)SAS/SATA RAID standardcard-RAID0,1,5,6,10,50,60-12Gb/s-2GB Cache-applicable 24 drive model SLOT4 EOP
0231YAGYfunction module-2488H V5-CN2M15RLCA1-XP450C-M 2G(AVAGO3508)SAS/SATA RAID standardcard-RAID0,1,5,6,10,50,60-12Gb/s-2GB Cache-applicable 25 drive model EOP
0231YAHAfunction module-2488H V5-CN2M16RLCA1-XP450C-M 2G(AVAGO3508)SAS/SATA RAID standardcard-RAID0,1,5,6,10,50,60-12Gb/s-2GB Cache-applicable 24 drive model SLOT6 EOP
0231YAHBfunction module-2488H V5-CN2M17RLCA1-XP450C-M 2G(AVAGO3508)SAS/SATA RAID standardcard-RAID0,1,5,6,10,50,60-12Gb/s-2GB Cache-applicable 24 drive model SLOT8 EOP
0231YAHCfunction module-2488H V5-CN2M18RLCA1-XP450C-M 2G(AVAGO3508)SAS/SATA RAID standardcard-RAID0,1,5,6,10,50,60-12Gb/s-2GB Cache-applicable 24NVMe model EOP
0231YAHDfunction module-2488H V5-CN2M11RLCAA1-XP450C-M 4G(AVAGO3508)SAS/SATA RAID standardcard-RAID0,1,5,6,10,50,60-12Gb/s-4GB Cache-applicable 8 drive model EOP
0231YAHEfunction module-2488H V5-CN2M12RLCAA1-XP450C-M 4G(AVAGO3508)SAS/SATA RAID standardcard-RAID0,1,5,6,10,50,60-12Gb/s-4GB Cache-applicable 8NVME+16HDD EOP
0231YAHFfunction module-2488H V5-CN2M13RLCAA1-XP450C-M 4G(AVAGO3508)SAS/SATA RAID standardcard-RAID0,1,5,6,10,50,60-12Gb/s-4GB Cache-applicable 24 drive model SLOT4 EOP
0231YAHGfunction module-2488H V5-CN2M14RLCAA1-XP450C-M 4G(AVAGO3508)SAS/SATA RAID standardcard-RAID0,1,5,6,10,50,60-12Gb/s-4GB Cache-applicable 24 drive model SLOT6 EOP
0231YAHHfunction module-2488H V5-CN2M15RLCAA1-XP450C-M 4G(AVAGO3508)SAS/SATA RAID standardcard-RAID0,1,5,6,10,50,60-12Gb/s-4GB Cache-applicable 24 drive model SLOT8 EOP
0231YAHJfunction module-2488H V5-CN2M16RLCAA1-XP450C-M 4G(AVAGO3508)SAS/SATA RAID standardcard-RAID0,1,5,6,10,50,60-12Gb/s-4GB Cache-applicable 25 drive model EOP
02312QWYFunction Module,9440-8i 0G,CN2M94408I0G,Other Cards,12G SAS RAID Card,no cache-8*12Gb/s SAS PHY-2 miniSAS HD internal interface Current Field replaceable
02312QWVFunction Module,9460-8i 2G,CN2M94608I2G,Other Cards,12G SAS RAID Card,2G cache-8*12Gb/s SAS PHY-2 miniSAS HD internal interface Current Field replaceable
0817Y002Super capacitor module,64mm*51mm*13.1mm,Wire mounting,split from 08170002,NA,7600uF,5h Current Field replaceable
06010262Other Storage Medium,LSI Flash Card,4GB,TFM,Supercap and 620mm Cable,No doc EOP Field replaceable
0231Y129Function Module,9560-8i 4G,CN2M95608I4G,9560-8i 4G Other Cards,12G SAS RAID Card,4G cache-8*12Gb/s SAS PHY-1 slimline internal interface,PCIE 4.0 X8-Vendor ID 1000-Device ID 10E2-Subvendor ID 1000-Subdevice ID 4010 Current Field replaceable
02312QWWFunction Module,9460-8i 4G,CN2M94608I4G,Other Cards,12G SAS RAID Card,4G cache-8*12Gb/s SAS PHY-2 miniSAS HD internal interface Current Field replaceable
03024RLGManufactured Board,SR230-M,BC11MSMA,M.2 RAID PCIE card-RAID0,1,JBOD,Support Sideband Management,No Cache(Avago3004),PCIE 3.0 X8-Vendor ID 1000-Device ID 005F-1,customraid,1*2 Current Field replaceable
03024JNEManufactured Board,SP460C-M 4G,CN21RLCAC,SAS/SATA RAID Card,PCIe card,RAID0,1,5,6,10,50,60,4GB Cache(Avago3516),Support SuperCap and Sideband Management,PCIE 3.0 X8-Vendor ID 1000-Device ID 0014-1,1*2 EOP Field replaceable
02312FWAFunction Module,12G SAS RAID Card,BC1M033512,SmartRAID 3152-8i RAID Card-PCIE 3.0 X8-2GB cache-RAID 0,1,5,6,10,50,60,1/10ADM-customraid Current Field replaceable
03024JNCManufactured Board,SP450C-M 4G,CN21RLCAA,SAS/SATA RAID Card,PCIe card,RAID0,1,5,6,10,50,60,4GB Cache(Avago3508),Support SuperCap and Sideband Management,PCIE 3.0 X8-Vendor ID 1000-Device ID 0016-1,customraid,1*2 Current Field replaceable
03024JNAManufactured Board,SP150-M,CN21RLNA,SAS/SATA,RAID PCIE CARD,RAID0,1,10,0 Cache(Avago3408),Support Sideband Management,PCIE 3.0 X8-Vendor ID 1000-Device ID 0017-1,customraid,1*2 EOP Field replaceable
03024JNBManufactured Board,SP450C-M 2G,CN21RLCA,SAS/SATA RAID Card,PCIe card,RAID0,1,5,6,10,50,60,2GB Cache(Avago3508),Support SuperCap and Sideband Management,PCIE 3.0 X8-Vendor ID 1000-Device ID 0016-1,customraid,1*2 Current Field replaceable
06030322Other Cards,English doc,Prohibition of separate shipment EOP Field replaceable
P/NDescription / SpecificationStatus
0231Y803function module-Servers-CN2M01ITGBA1-XP210 Intel I350 2*GE+half-height half-length(incl. half-height & full-height brackets)standard network adapter-PCIE 2.0 X4-Vendor ID 8086-Device ID 1521-2 Current
0231Y804function module-Servers-CN2M01ITGC1-XP212 Intel I350 4*GE+half-height half-length(incl. half-height & full-height brackets)standard network adapter-PCIE 2.0 X4-Vendor ID 8086-Device ID 1521-4 Current
0231Y809function module-Servers-CN2M04ITGG1-XP330 Ethernet adapter-10Gb optical port(Intel X710)-dual-port-SFP+(optical module not included)-half-height half-length(incl. half-height & full-height brackets)-PCIe 3.0 x8 Current
0231Y812function module-Servers-CN2M03ITGH1-XP332 Ethernet adapter-10Gb optical port(Intel XL710)-quad-port-SFP+(optical module not included)-half-height half-length(incl. half-height & full-height brackets)-PCIe 3.0 x8 Current
0231Y829function module-Servers-CN2M06ITGG1-XP330 Ethernet adapter-10Gb optical port(Intel X710)-dual-port-SFP+(incl. 2 optical modules)-half-height half-length(incl. half-height & full-height brackets)-PCIe 3.0 x8(domestic & overseas) Current
0231Y830function module-Servers-CN2M05ITGH1-XP332 Ethernet adapter-10Gb optical port(Intel XL710)-quad-port-SFP(incl. 4 optical modules)-half-height half-length(incl. half-height & full-height brackets)-PCIe 3.0 x8(domestic & overseas) Current
0257Y099PCIe-network adapter-2288H V6-E810XXVDA2G1P5-network adapter-25G optical port(E810XXVDA2G1P5 978333)-dual-port-SFP28(optical module not included)-PCIE 4.0 X8-8086-159b|0003-2-with driver package Current
0257Y109PCIe-network adapter-2288H V6-LPE31000-AP-Emulex -FC HBA card-16Gb/s(LPe31000)-single-port-SFP+(incl. 1 multimode optical modules)-PCIE 3.0 x8-Vendor ID 10DF-Device ID E300-1-Subvendor ID 10DF-Subdevice ID E311-with driver package Current
0257Y110PCIe-network adapter-2288H V6-LPe31002-AP-Emulex -FC HBA card-16Gb/s(LPe31002)-dual-port-SFP+(incl. 2 multimode optical modules)-PCIE 3.0 x8-Vendor ID 10DF-Device ID E300-2-Subvendor ID 10DF-Subdevice ID E310-with driver package Current
0257Y112PCIe-network adapter-2288H V6-LPe32002-AP-Emulex -FC HBA card-32Gb/s(LPe320PCIE 3.0 x8-Vendor ID 10DF-Device ID E300-2-Subvendor ID 10DF-Subdevice ID E30002)-dual-port-SFP+(incl. 2 multimode optical modules)--with driver package Current
0257Y116PCIe-network adapter-2288H V6-X710T2L-10Gb/s-64bit-10GBASE-T-2 ports-PCIE 3.0 x8-8086-15ff-2-with driver package Current
0302Y044manufactured board-Public Module-CN21ITGC1-XP212 I350 4*GE standard network adapter-PCIE 2.0 X4-Vendor ID 8086-Device ID 1521-4-Subvendor ID 1f24-Subdevice ID 2001-1*2 Current
0302Y047manufactured board-Public Module-CN21ITGH1-XP332 Ethernet adapter-10Gb optical port(Intel XL710)-quad-port-SFP+(optical module not included)-PCIE 3.0 X8-Vendor ID 8086-Device ID 1572-4-Subvendor ID 1f24-Subdevice ID 2004-1*2 Current
06030382other board card-HBA Card QLE2692-CEM-BK-FC dual-port-16Gb/s-PCIE 3.0 x8-Vendor ID 1077-Device ID 2261-2-incl. multimode optical module-Chinese & English documentation-half-height half-length Current
0603Y023other board card-HBA Card QLE2772-CEM-BK-FC dual-port-32Gb/s-PCIE 4.0 x8-1077-2281-2-Chinese & English documentation-half-height half-length Current
02310YHPfunction module-X6000-CN21ITGAA15-Intel 82599 2*10GE SFP+-half-height half-length-X8 standard network adapter-incl.NIC panel-supports NCSI-PCIE 2.0 X8-Vendor ID 8086-Device ID 10FB-2 EOP
02311CWMfunction module-server-CN21ITGC01-Intel I350 4*GE+half-height half-length+full-height bracket standard network adapter-PCIE 2.0 X4-Vendor ID 8086-Device ID 1521-4 EOP
02311EUXfunction module-X6000-CN2ITGAA20-Intel 82599 2*10GE SFP+ half-height half-length standard network adapter with optical module supports NCSI-PCIE 2.0 X8-Vendor ID 8086-Device ID 10FB-2 EOP
02311MSPfunction module-rack server-CN2M01ITGD-Ethernet adapter-10Gb electrical port(RJ45)(Intel X540)-dual-port-RJ45-PCIe 2.0 x8 EOP
02311PBJfunction module-ES3000 V3-CN2M10FACP-ES3600C-3200GB-3 DWPD-PCIE 3.0 X4-Vendor ID 19e5-Device ID 0123-1,Model number HWE36P43032M000N,half-height half-length card,NVMe SSD EOS
02311PBKfunction module-ES3000 V3-CN2M10FACM-ES3600C-1600GB-3 DWPD-PCIE 3.0 X4-Vendor ID 19e5-Device ID 0123-1,Model number HWE36P43016M000N,half-height half-length card,NVMe SSD EOS
02311PEMfunction module-ES3000 V3-CN2M10FACL-ES3600C-1200GB-3 DWPD-PCIE 3.0 X4-Vendor ID 19e5-Device ID 0123-1,Model number HWE36P43012M000N,half-height half-length card,NVMe SSD EOS
02311PXAfunction module-rack server-CN2M01ITGE-Ethernet adapter-10Gb electrical port(RJ45)(Intel X550)-dual-port-RJ45-PCIe 2.0 x8 EOP
02311QMTfunction module-RH2288H V3-CN2M01ITGF-Ethernet adapter-10Gb optical port(Mellanox MT27712A0)-dual-port-SFP+(optical module not included)-PCIe 3.0 x8-SP333 EOP
02311RMWfunction module-rack server-CN2M01ITGG-Ethernet adapter-10Gb optical port(Intel X710)-dual-port-SFP+(optical module not included)-PCIe 3.0 x8 EOP
02311RMYfunction module-rack server-CN2M02ITGH-Ethernet adapter-10Gb optical port(Intel XL710)-quad-port-SFP+(optical module not included)-PCIe 3.0 x8 EOP
02311SHAfunction module-ES3000 V3-CN2M10FACB-ES3600C-800GB-3 DWPD-PCIE 3.0 X4-Vendor ID 19e5-Device ID 0123-1,Model number HWE36P43008M000N,half-height half-length card,NVMe SSD EOS
02311SNLfunction module-ES3000 V3-CN2M10FAMS-ES3620C-6400GB-3 DWPD-PCIE 3.0 X4-Vendor ID 19e5-Device ID 0123-1,Model number HWE36P43064M001N,half-height half-length card,NVMe SSD EOS
02311WQTfunction module-Server-CN21ITGB02-Intel I350 2*GE+half-height half-length+full-height bracket standard network adapter-PCIE 2.0 X4-Vendor ID 8086-Device ID 1521-2 EOP
02311WTSfunction module-Servers-CN2M02ITGF-Ethernet adapter-10Gb optical port(Mellanox MT27712A0)-dual-port-SFP+(incl. 2 multimode optical modules)-PCIe 3.0 x8-SP333 EOP
02311WTTfunction module-Servers-CN2M03ITGG-Ethernet adapter-10Gb optical port(Intel X710)-dual-port-SFP+(incl. 2 multimode optical modules)-PCIe 3.0 x8 EOP
02311WTUfunction module-Servers-CN2M04ITGG-Ethernet adapter-10Gb optical port(Intel XL710)-quad-port-SFP+(incl. 4 multimode optical modules)-PCIe 3.0 x8 EOP
02311WTVfunction module-Servers-CN2M06ITGG-Ethernet adapter-25Gb optical port(Mellanox CX4-lx EN)-dual-port-SFP28(incl. 2 multimode optical modules)-PCIe 3.0 x8 EOP
02311WWEfunction module-Servers-CN2M05ITGG-Ethernet adapter-40Gb optical port(Mellanox CX3-Pro)-dual-port-QSFP+(incl. 2 multimode optical modules)-PCIe 3.0 x8 EOP
02312BFFfunction module-SP350-BC5M01IBMA-IB card-EDR(100Gb/s)(Mellanox ConnectX-5 VPI)-single-port-QSFP28(optical module not included)-half-height half-length-full-height bracket-PCIE 3.0 x16 EOP
02312BHUfunction module-SP350-BC5M02IBMA-IB card-EDR(100Gb/s)(Mellanox ConnectX-5 VPI)-single-port-QSFP28(optical module not included)-half-height half-length-half-height bracket-PCIE 3.0 x16 EOP
02312BHVfunction module-SP350-BC5M03IBMA-IB card-EDR(100Gb/s)(Mellanox ConnectX-5 VPI)-single-port-QSFP28(optical module not included)-half-height half-length-full-height bracket+half-height bracket-PCIE 3.0 x16 EOP
02312BHXfunction module-SP351-BC5M01IBMB-IB card-EDR(100Gb/s)(Mellanox ConnectX-5 VPI)-2 endport-QSFP28(optical module not included)-half-height half-length-full-height bracket-PCIE 3.0 x16 EOP
02312BHYfunction module-SP351-BC5M02IBMB-IB card-EDR(100Gb/s)(Mellanox ConnectX-5 VPI)-2 endport-QSFP28(optical module not included)-half-height half-length-half-height bracket-PCIE 3.0 x16 EOP
02312BJAfunction module-SP351-BC5M03IBMB-IB card-EDR(100Gb/s)(Mellanox ConnectX-5 VPI)-2 endport-QSFP28(optical module not included)-half-height half-length-full-height bracket+half-height bracket-PCIE 3.0 x16 EOP
02312JEVfunction module-2288H V3-BC1P4GPU1-NVIDIA-GPU-Tesla P4-PN:900-2G414-0000-000,8GB Memory/192GB/s Bandwidth/PCIE 3.0 X16-10DE-1BB3-1-75W/Single Slot/PassiveCoolling EOP
02312JFLfunction module-SP380-BC5M02ETHE-Ethernet adapter-25GE optical port(Mellanox CX-4 Lx)-dual-port-SFP28(optical module not included)-half-height half-length(incl. half-height & full-height brackets(loose))-PCIe 3.0 x8 EOP
02312JRTfunction module-ES3000 V5-CN2M20PWBD-ES3600C-800GB-3 DWPD-PCIE 3.0 X4-Vendor ID 19e5-Device ID 3714-1,Model number HWE56P43800M002N,half-height half-length card,NVMe SSD EOP
02312JRVfunction module-ES3000 V5-CN2M21PWBA-ES3600C-1600GB-3 DWPD-PCIE 3.0 X4-Vendor ID 19e5-Device ID 3714-1,Model number HWE56P431T6M002N,half-height half-length card,NVMe SSD EOP
02312JRWfunction module-ES3000 V5-CN2M22PWBB-ES3600C-3200GB-3 DWPD-PCIE 3.0 X4-Vendor ID 19e5-Device ID 3714-1,Model number HWE56P433T2M002N,half-height half-length card,NVMe SSD EOP
02312JRXfunction module-ES3000 V5-CN2M23PMBC-ES3600C-6400GB-3 DWPD-PCIE 3.0 X4-Vendor ID 19e5-Device ID 3714-1,Model number HWE56P436T4M002N,half-height half-length card,NVMe SSD EOP
02312LDKfunction module-SP380-BC5M03ETHE-Ethernet adapter-25GE optical port(Mellanox CX-4 Lx)-dual-port-SFP28(optical module not included)-half-height half-length-full-height bracket-PCIe 3.0 x8 EOP
02312TABfunction module-Server-ES3610C800GHH-ES3610C-800GB-3 DWPD-PCIE 3.0 X4-Vendor ID 19e5-Device ID 3714-1,Model number HWE56P43800M005N,half-height half-length card bundle code,NVMe SSD EOP
02312TADfunction module-Server-ES3610C800GFH-ES3610C-800GB-3 DWPD-PCIE 3.0 X4-Vendor ID 19e5-Device ID 3714-1,Model number HWE56P43800M005N,half-height half-length card,full-height bundle code,NVMe SSD EOP
02312TAEfunction module-Server-ES3610C1600GHH-ES3610C-1600GB-3 DWPD-PCIE 3.0 X4-Vendor ID 19e5-Device ID 3714-1,Model number HWE56P431T6M005N,half-height half-length card bundle code,NVMe SSD EOP
02312TAFfunction module-Server-ES3610C1600GFH-ES3610C-1600GB-3 DWPD-PCIE 3.0 X4-Vendor ID 19e5-Device ID 3714-1,Model number HWE56P431T6M005N,half-height half-length card,full-height bundle code,NVMe SSD EOP
02312TAGfunction module-Server-ES3610C3200GHH-ES3610C-3200GB-3 DWPD-PCIE 3.0 X4-Vendor ID 19e5-Device ID 3714-1,Model number HWE56P433T2M005N,half-height half-length card bundle code,NVMe SSD EOP
02312TAHfunction module-Server-ES3610C3200GFH-ES3610C-3200GB-3 DWPD-PCIE 3.0 X4-Vendor ID 19e5-Device ID 3714-1,Model number HWE56P433T2M005N,half-height half-length card,full-height bundle code,NVMe SSD EOP
02312TAJfunction module-Server-ES3610C6400GHH-ES3610C-6400GB-3 DWPD-PCIE 3.0 X4-Vendor ID 19e5-Device ID 3714-1,Model number HWE56P436T4M005N,half-height half-length card bundle code,NVMe SSD EOP
02312TAKfunction module-Server-ES3610C6400GFH-ES3610C-6400GB-3 DWPD-PCIE 3.0 X4-Vendor ID 19e5-Device ID 3714-1,Model number HWE56P436T4M005N,half-height half-length card,full-height bundle code,NVMe SSD EOP
02312VVUfunction module-Public Module-BC5M03ETHK-SP382 Ethernet adapter-25GE optical port(Mellanox CX5)-dual-port-SFP28(optical module not included)-half-height half-length-full-height bracket-PCIe 3.0 x8 EOP
02313BTVfunction module-MCX314A-BCCT-network adapter-40 Gigabit-64bit-QSFP-2 ports-PCIE 3.0 X8-15b3-1007-1-No Driver CD-without optical module EOP
02313BTWfunction module-MCX353A-FCBT-Infiniband FDR IB card-56Gb-single-port-QSFP-PCIe 3.0 x8 EOP
02313BTXfunction module-MCX354A-FCBT-Infiniband FDR IB card-56Gb-dual-port-QSFP-PCIe 3.0 x8 EOP
0231Y044function module-Public Module-BC5M03ETHE01-Ethernet adapter-25GE optical port(Mellanox CX-4 Lx)-dual-port-SFP28(incl. 2*10GE optical module)-half-height half-length-full-height bracket-PCIe 3.0 x8 EOP
0231Y058function module-Public Module-BC5M02ETHE01-Ethernet adapter-25GE optical port(Mellanox CX-4 Lx)-dual-port-SFP28(incl. 2*10GE optical module)-half-height half-length(incl. half-height & full-height brackets(loose))-PCIe 3.0 x8 EOP
0231Y808function module-Servers-CN2M03ITGG1-XP330 Ethernet adapter-10Gb optical port(Intel X710)-dual-port-SFP+(incl. 2 optical modules)-half-height half-length(incl. half-height & full-height brackets)-PCIe 3.0 x8 EOP
0231Y810function module-Servers-CN2M01ITGH1-XP332 Ethernet adapter-10Gb optical port(Intel XL710)-quad-port-SFP+(incl. 4 optical modules)-half-height half-length(incl. half-height & full-height brackets)-PCIe 3.0 x8 EOP
0231Y817function module-Servers-BC5M04ETHE1-XP380 Ethernet adapter-25GE optical port(Mellanox CX-4 Lx)-dual-port-SFP28(optical module not included)-half-height half-length(incl. half-height & full-height brackets(loose))-PCIe 3.0 x8 EOM
0231Y820function module-Servers-BC5M07ETHE1-XP380 Ethernet adapter-25GE optical port(Mellanox CX-4 Lx)-dual-port-SFP28(incl. 2*10GE optical module)-half-height half-length(incl. half-height & full-height brackets(loose))-PCIe 3.0 x8 EOM
0257Y094PCIe-network adapter-2288H V6-MCX4121A-ACAT-Ethernet adapter-25Gb optical port(Mellanox CX4-lx EN)-dual-port-SFP28(optical module not included)-PCIE 3.0 X8-15b3-1015-2-with driver package EOP
0257Y095PCIe-network adapter-2288H V6-MCX512A-ACAT-network adapter-25Gb optical port(MCX512A-ACAT)-dual-port-SFP28(optical module not included)-PCIE 3.0 x8-15b3-1017-2-Subvendor ID 15b3-Subdevice ID 0020-with driver package EOP
0257Y100PCIe-network adapter-2288H V6-MCX515A-CCAT-network adapter-100Gb optical port(MCX515A-CCAT)-single-port-QSFP28(optical module not included)-PCIE 3.0 x16-15b3-1017-1-with driver package EOM
0257Y111PCIe-network adapter-2288H V6-LPe32000-AP-Emulex -FC HBA card-32Gb/s(LPe32000)-single-port-SFP+(incl. 1 multimode optical modules)-PCIE 3.0 x8-Vendor ID 10DF-Device ID E300-1-Subvendor ID 10DF-Subdevice ID E301-with driver package EOP
0257Y113PCIe-network adapter-2288H V6-MCX653105A-ECAT-Infiniband MCX653105A-ECAT-HDR100/EDR IB single-port-100Gb/s-PCIE 4.0 x16-Vendor ID 15b3-Device ID 101b-1|2-Subvendor ID 15b3-Subdevice ID 0006-with driver package EOM
0257Y178PCIe-network adapter-2288H V6-MCX516A-CCAT-network adapter-100 Gigabit-64bit-QSFP28(optical module not included)-2 Ports-PCIE 3.0 x16-Vendor ID 15b3-Device ID 1017-2-Subvendor ID 15b3-Subdevice ID 0007-with driver package EOP
06030216other board card-computer accessory-PCIE 2.0 X4|PCIE 1.0 X8-Vendor ID 10DF-Device ID F100-1-8Gbps single-channel,fibre-channel multimode LC optical interface-English documentation-not for separate shipment EOM
06030217other board card-computer accessory-PCIE 2.0 X4|PCIE 1.0 X8-Vendor ID 10DF-Device ID F100-2-8Gbps dual-channel-fibre-channel multimode LC optical interface-English documentation-not for separate shipment EOM
06030220other board card-DualPort FC HBA Card-PCIE 2.0 X4-1077-2532-2-8Gbps dual-channel,fibre-channel multimode LC optical interface-no-included 1pcs low-profile bracket EOM
06030221other board card-computer accessory-PCIE 2.0 X4-1077-2532-1-8Gbps single-channel,fibre-channel multimode LC optical interface-no EOM
06030275other board card-HBA Card LPe16000B-M6-FC single-port-16Gb/s-PCIE 3.0 x8-Vendor ID 10df-Device ID e200-1-English documentation-multimode optical module,included 1pcs low-profile bracket-half-height half-length-not for separate shipment EOM
06030276other board card-HBA Card LPe16002B-M6-FC dual-port-16Gb/s-PCIE 3.0 x8-Vendor ID 10df-Device ID e200-2-English documentation-multimode optical module,included 1pcs low-profile bracket-half-height half-length--not for separate shipment EOM
06030284IB card-Infiniband MCX354A-FCBT-FDR dual-port-56Gb/s-PCIE 3.0 X8-Vendor ID 15b3-Device ID 1003-1-English documentation-half-height half-length EOM
06030285IB card-Infiniband MCX353A-FCBT-FDR single-port-56Gb/s-PCIE 3.0 X8-Vendor ID 15b3-Device ID 1003-1-English documentation-half-height half-length EOM
06030317other board card-RAID Card SAS9380-8e-SAS 12Gb/s-PCIE 3.0 x8-Vendor ID 1000-Device ID 005d-1-English documentation-half-height half-length,not for separate shipment EOS
06030347IB card-Mellanox MCX455A-ECAT-EDR single-port-100Gb/s-PCIE 3.0 X16-Vendor ID 15b3-Device ID 1013-1-English documentation-half-height half-length(FW 12.17.2032 and above) EOM
06030348IB card-Mellanox MCX456A-ECAT-EDR dual-port-100Gb/s-PCIE 3.0 X16-Vendor ID 15b3-Device ID 1013-2-English documentation-half-height half-length(FW 12.17.2032 and above) EOM
06030358IB card-Network Card,Intel® Omni-Path Host Fabric Interface Adapter-100Gbps-PCIE 2.0 x16-Vendor ID 8086-Device ID 24F0-1-English documentation EOM
06030379other board card-HBA Card QLE2694L-HUA-SP-16Gb-quad-port-PCIE 3.0 x8-Vendor ID 1077-Device ID 2071-4-SFF(integrated 4 x non-detachable multimode optical modules)-English documentation-half-height half-length EOS
06030381other board card-HBA Card QLE2690-HUA-SP-FC single-port-16Gb/s-PCIE 3.0 x8-Vendor ID 1077-Device ID 2261-1-no-multimode optical module-half-height half-length EOM
06030390other board card-HBA Card QLE2740-HUA-SP-FC single-port-32Gb/s-PCIE 3.0 x8-Vendor ID 1077-Device ID 2261-1-no-multimode optical module-half-height half-length EOM
06030392other board card-HBA Card QLE2742-HUA-SP-FC dual-port-32Gb/s-PCIE 3.0 x8-Vendor ID 1077-Device ID 2261-2-no-multimode optical module-half-height half-length EOM
06030424other board card-PCIE 3.1 X8-Vendor ID 1000-Device ID 00AF-1-Subvendor ID 1000-Subdevice ID 3030-12G SAS HBA card-not supported RAID-no cache-8*12Gb/s SAS PHY-2 miniSAS HD external interface-9400-8e-English documentation-included 1pcs low-profile bracket-not for separate shipment EOM
0603Y022other board card-HBA Card QLE2770-CEM-BK-FC single-port Port-32Gb/s-PCIE 4.0 x8-1077-2281-1-Chinese & English documentation-half-height half-length EOM
06310058network adapter-Gigabit-LC Fiber Optic-2 endport-PCIE 2.0 X4-8086-1522-2-no driver disc-all-with optical module,half-height half-length EOM
06310102network adapter-40 Gigabit-64bit-QSFP+-1 port-PCIE 3.0 X8-8086-1584-1-NO Driver CD-MM#950495-With Optical Module EOM
06310105network adapter-40 Gigabit-64bit-QSFP-2 ports-PCIE 3.0 X8-15b3-1007-1-No Driver CD-without optical module EOM
06310106network adapter-25 Gigabit-64bit-SFP28-2 ports-PCIE 3.0 X8-15b3-1015-2-without driver EOM
06310121network adapter-100 Gigabit-64bit-QSFP28-2 endport-PCIE 3.0 X16-15B3-1013-2-without driver-without optical module EOM
06310132network adapter-XXV710DA2G1P5 948661-25 Gigabit-64bit-SFP28-2 endport-PCIE 3.0 X8-8086-158b-2-without driver EOM
06310146network adapter-40 Gigabit-64bit-QSFP+(optical module not included)-2 Ports-PCIE 3.0 x8-8086-1583-2-without driver EOM
06320133video card-GPU card-Quadro P400-PN:900-5G212-2500-000/2GB GDDR5 Memory/32GB/s Bandwidth/PCIE 3.0 x16-10DE-1CB3|0FB9-2,30W/SingleSlot/ActiveCooling-no EOP
06320150video card-GPU card-Quadro P620,PN:900-5G212-2540-000/2GB DDR5 Memory/80GB/s Bandwidth/PCIE 3.0 x16-Vendor ID 10DE-Device ID 1CB6|0FB9-2-subVerdorID 10DE-subDeviceID 0x1264-40W/SingleSlot/ActiveCooling/full-height bracket-no EOP
3406Y008High Speed Transceiver,SFP28,850nm,25G,-8.4dBm,2.4dBm,-10.3dBm,LC,MM,0.1km,Original 34061254 split Current Field replaceable
3406Y006XFP|SFP+ Transceiver,SFP+,850nm,10Gb/s,-7.3dBm,-1dBm,-9.9dBm,LC,0.3km Current Field replaceable
34061089High Speed Transceiver,QSFP28,850nm,100G,-8.4dBm,2.4dBm,-10.3dBm,MPO,MM,0.1km,OM4 Current Engineer replace
34061254High Speed Transceiver,SFP28,850nm,25G,-8.4dBm,2.4dBm,-10.3dBm,LC,MM,0.1km Current Field replaceable
03025SNTManufactured Board,Public Module,BC51ETHE,SP380 Ethernet Adapter,25GE(Mellanox CX-4 Lx),Dual-Port,SFP28(without Optical Transceiver),PCIE 3.0 x8-Vendor ID 15b3-Device ID 1015-2-Subvendor ID 19e5-Subdevice ID d130,1*2 Current Field replaceable
06320107Video Card,GPU-Tesla P4,PN:900-2G414-0000-000,8GB Memory/ 192GB/s Bandwidth/ PCIE 3.0 X16-10DE-1BB3-1,75W/ Single Slot/PassiveCoolling,NULL EOP Field replaceable
06320147Video Card,GPU-Tesla T4,900-2G183-0000-001,16GB Memory/ 320GB/s Bandwidth/ PCIE 3.0 X16-10DE-1EB8-1,70W/ Single Slot/PassiveCoolling/ATX Bracket,loose LP Braket,English doc Current Field replaceable
03023TYJManufactured Board,Public Module,CN21ITGF,Ethernet Adapter,10Gb Optical Interface,2-Port,PCIE 3.0 X8-Vendor ID 15b3-Device ID 1015-2-Subvendor ID 19e5-Subdevice ID d11b,1*2 Current Field replaceable
03030WSQFinished Board,X6000,CN21ITGAA13,Intel 82599 2*10GE SFP+ Half-height Half-length X8 PCIE Ethernet Card NCSI Supported,PCIE 2.0 X8-Vendor ID 8086-Device ID 10FB-2 Current Field replaceable
3406Y011High Speed Transceiver,QSFP28,850nm,100G,-8.4dBm,2.4dBm,-10.3dBm,MPO,MM,0.1km,OM4 Original 34061089 split Current Field replaceable
3406Y009High Speed Transceiver,QSFP+,850nm,41.25Gbps,-7.6dBm,0.5dBm,-9.5dBm,MPO,0.15km,Original 34060662-002 split Current Field replaceable
34060495XFP|SFP+ Transceiver,SFP+,1310nm,10Gb/s,-8.2dBm,0.5dBm,-12.6dBm,LC,SM,10km Current Field replaceable
3406Y007XFP|SFP+ Transceiver,SFP+,1310nm,10Gb/s,-8.2dBm,0.5dBm,-12.6dBm,LC,10km Current Field replaceable
0302Y437Manufactured Board,XP380,BC51ETHE3,Ethernet Adapter,25GE(Mellanox CX-4 Lx),Dual-Port,SFP28(without Optical Transceiver),PCIE 3.0 x8-Vendor ID 15b3-Device ID 1015-2-Subvendor ID 1f24-Subdevice ID 2005,1*2 Current Field replaceable
0302Y043Manufactured Board,Public Module,CN21ITGBA1,XP210 I350 2*GE PCIE Card,PCIE 2.0 X4-Vendor ID 8086-Device ID 1521-2-Subvendor ID 1f24-Subdevice ID 2000,1*2 Current Field replaceable
0302Y046Manufactured Board,Public Module,CN21ITGG1,XP330 Ethernet Adapter,10Gb Optical Interface(Intel X710),2-Port,SFP+(without Optical Transceiver),PCIE 3.0 X8-Vendor ID 8086-Device ID 1572-2-Subvendor ID 1f24-Subdevice ID 2003,1*2 Current Field replaceable
06310191Network Card,25 Gigabit,64bit,SFP28,2 ports,PCIE 3.0 X8-15b3-1015-2,No Driver CD Current Field replaceable
06310149Network Card,100 Gigabit,64bit,QSFP28(without Optical Transceiver),1 ports,PCIE 3.0 x16-15b3-1017-1-Subvendor ID 15b3-Subdevice ID 0006,No Driver CD Current Field replaceable
06030393Other Cards,HBA Card LPe32002-AP,FC Double Ports-32Gb/s,PCIE 3.0 x8-Vendor ID 10DF-Device ID E300-2-Subvendor ID 10DF-Subdevice ID E300,English doc,1pcs short bracket,half width half length-Prohibition of separate shipment Current Field replaceable
06030391Other Cards,HBA Card LPe32000-AP,FC Single Port-32Gb/s,PCIE 3.0 x8-Vendor ID 10DF-Device ID E300-1-Subvendor ID 10DF-Subdevice ID E301,English doc,1pcs short bracket,half width half length-Prohibition of separate shipment Current Field replaceable
06030463Other Cards,HBA Card LPe31002-AP,FC Double Ports-16Gb/s,PCIE 3.0 x8-Vendor ID 10DF-Device ID E300-2-Subvendor ID 10DF-Subdevice ID E310,English doc,Full-height and half-height bracket,half width half length Current Field replaceable
06030462Other Cards,HBA Card LPe31000-AP,FC single Ports-16Gb/s,PCIE 3.0 x8-Vendor ID 10DF-Device ID E300-1-Subvendor ID 10DF-Subdevice ID E311,English doc,1pcs short bracket,half width half length Current Field replaceable
06030516IB Card,Infiniband MCX653105A-ECAT,HDR100/EDR single-port -100Gb/s- PCIE 4.0 x16-Vendor ID 15b3-Device ID 101b-1|2-Subvendor ID 15b3-Subdevice ID 0006-tall bracket,English doc Current Field replaceable
34060662High Speed Transceiver,QSFP+,850nm,41.25Gbps,-7.6dBm,0.5dBm,-9.5dBm,MPO,MMF,0.15km EOP Field replaceable
34060785High Speed Transceiver,QSFP+,56Gbps,0.005km Current Field replaceable
34060786High Speed Transceiver,QSFP+,56Gbps,0.01km Current Field replaceable
03022TSCManufactured Board,X6000,CN21ITGB,I350 2*GE PCIE Card,PCIE 2.0 X4-Vendor ID 8086-Device ID 1521-2,1*2 EOP Field replaceable
03022UTKManufactured Board,X6000,CN21ITGC,I350 4*GE PCIE Card,PCIE 2.0 X4-Vendor ID 8086-Device ID 1521-4-Subvendor ID 19e5-Subdevice ID d113,1*2 Current Field replaceable
03023TYLManufactured Board,SP332,CN21ITGH,Ethernet Adapter,10Gb Optical Interface(Intel XL710),4-Port,SFP+(without Optical Transceiver),PCIE 3.0 X8-Vendor ID 8086-Device ID 1572-4-Subvendor ID 19e5-Subdevice ID d11d,1*2 Current Field replaceable
03023SCWManufactured Board,Public Module,CN21ITGE,Ethernet Adapter,10Gb Electrical Interface(Intel X550),2-Port,RJ45,PCIE 2.0 X8-Vendor ID 8086-Device ID 1563-2-Subvendor ID 19e5-Subdevice ID d11a,1*2 Current Field replaceable
03023TYKManufactured Board,Public Module,CN21ITGG,Ethernet Adapter,10Gb Optical Interface(Intel X710),2-Port,SFP+(without Optical Transceiver),PCIE 3.0 X8-Vendor ID 8086-Device ID 1572-2,1*2 Current Field replaceable
06310151Network Card,40 Gigabit,64bit,QSFP28,2 port,PCIE 3.0 X16-15b3-1013-2,No Driver CD EOP Field replaceable
03023KWFManufactured Board,Public Module,CN21ITGD,Ethernet Adapter,10Gb Electrical Interface(Intel X540),2-Port,RJ45,PCIE 2.0 X8-Vendor ID 8086-Device ID 1528-2,1*2 EOP Field replaceable
03022PKQManufactured Board,X6000,CN21ITGBA,I350 2*GE PCIE Card,PCIE 2.0 X4-Vendor ID 8086-Device ID 1521-2-Subvendor ID 19e5-Subdevice ID d112,1*2 Current Field replaceable
03024QAXManufactured Board,SP350,BC51IBMA,Infiniband card-EDR(100Gb/s)(MLX CX5)-Single port-QSFP28(without Optical module)-Half-height Half-length(without panel),PCIE 3.0 x16-Vendor ID 15b3-Device ID 1017-1-Subvendor ID 19e5-Subdevice ID d120,1*2 Current Field replaceable
03024QAYManufactured Board,SP351,BC51IBMB,Infiniband card-EDR(100Gb/s)(MLX CX5)-Dual port-QSFP28(without Optical module)-Half-height Half-length(without panel),PCIE 3.0 x16-Vendor ID 15b3-Device ID 1017-2- Subvendor ID 19e5-Subdevice ID d126,1*2 Current Field replaceable
3406Y001Active Optical Cable Assembly,200Gb/s to 2x100Gb/s, QSFP56 to 2xQSFP56,IB HDR, 200Gpbs, LSZH, black pulltab,0.005km Current Field replaceable
34061319Active Optical Cable Assembly,QSFP28,100Gbps IB EDR,0.005km Current Engineer replace
34061321Active Optical Cable Assembly,QSFP28,100Gbps IB EDR,0.02km Current Engineer replace
34061320Active Optical Cable Assembly,QSFP28,100Gbps IB EDR,0.01km Current Engineer replace
06310148Network Card,25 Gigabit,64bit,SFP28(without Optical Transceiver),2 Ports,PCIE 3.0 x8-14e4-16d7-2,No Driver CD Current Field replaceable
34060779XFP|SFP+ Transceiver,SFP+,850nm,14.025Gbps,-7.8dBm,0dBm,-10.5dBm,LC,MMF,0.1km EOP Field replaceable
02311YJMFunction Module,Enterprise Communication Product,SFP-25G-AOC-10M-A,Active Optical Cable ,SFP28,25G,(850nm,10m,AOC,Aqua) Current Engineer replace
02311YJPFunction Module,Enterprise Communication Product,SFP-25G-AOC-20M-A,Active Optical Cable ,SFP28,25G,(850nm,20m,AOC,Aqua) Current Engineer replace
34060521Optical Transceiver,SFP+, 850nm, 8.5G, -8.2dBm~-1.3dBm,-11.2dBm,LC,MMF,0.15km EOP Field replaceable
34061316Active Optical Cable Assembly,SFP28 AOC,25.78125G,0.003km Current Engineer replace
03025YFSManufactured Board,Public Module,BC51ETHC,PCIe to OCP2.0 adaptor-PCIE 3.0 X8,Board ID 0X53,1*2 Current Field replaceable
06310155Network Card,25 Gigabit,64bit,SFP28(without Optical Transceiver),2 Ports,PCIE 3.0 x8-15b3-1017-2,No Driver CD Current Field replaceable
06310209Network Card,25GE,64bit,SFP28,4,PCIE 3.0 x16-Vendor ID 19e5-Device ID 1822-4,No Driver CD,BPPM VE200S4P Current Field replaceable
03025AAKManufactured Board,SP520,BC51FCAA,FC HBA Adapter,16G(Hi1822),2-Port,SFP+(without Optical Transceiver),Without Panel,PCIE 3.0 x8-Vendor ID 19e5-Device ID 0203-2,1*2 EOP Field replaceable
03025SVVManufactured Board,SP522,BC51FCAC,FC HBA Adapter,8G(Hi1822),2-Port,SFP+(without Optical Transceiver),Without Panel,PCIE 3.0 x8-Vendor ID 19e5-Device ID 0212-2,1*2 EOP Field replaceable
03026PWBManufactured Board,Public Module,BC51ETHL,Ethernet Adapter,25GE(Hi1822),2-Port,SFP28(without Optical Transceiver),PCIE 3.0 x8-Vendor ID 19e5-Device ID 0206-2,1*2 Current Field replaceable
03029XTAManufactured Board,2488H V5,BC62MZHAA,2488H V5 Mezzanine Board,Board ID 0X04,1*1 EOP Field replaceable
P/NDescription / SpecificationStatus
03024QEHmanufactured board-2288H V5-BC11TPMA-TPM2.0 card(SPI)-international dedicated-5*4 Current
03024QEJmanufactured board-2288H V5-BC11TPMB-TCM card(SPI)-5*4 Current
03025HSWManufactured Board,2288H V5,BC11TPMC,TPM2.0 Card(SPI), China Dedicated,5*4 Current Engineer replace
P/NDescription / SpecificationStatus
03022HXWmanufactured board-RH2288H V3-BC11EHBC-RH2288H V3 8 drive backplane-Board ID 0X71-1*2 NONE
03022JWWmanufactured board-RH2288H V3-BC11THBE-RH2288H V3 24 drive backplane-Board ID 0X72-1*2 NONE
03023WADmanufactured board-2288H V3-BC11THBP-24 NVMe drive backplane-Board ID 0X7b NONE
03024EAKmanufactured board-2488 V5-BC62HBPA-drive backplane-Board ID 0X78-1*2 NONE
03024MSHmanufactured board-RH2288H V3-BC11THBHB-RH2288H V3 25 drive dual RAID EXP drive backplane-Board ID 0X75-1*2 NONE
03029JRYmanufactured board-2288H V5-BC11EHBCD-2288H V5 8 drive backplane-1*2 NONE
0302Y071manufactured board-2288H V5-BC11THBHB1-25*2.5inch HDD Expander drive backplane-Board ID 0X75-1*1 NONE
03024JNLManufactured Board,2488H V5,BC62HBPD,2488H V5 8NVME backplane,Board ID 0XC3,1*2 EOP Field replaceable
P/NDescription / SpecificationStatus
021313361500W enhanced platinum AC power supply(model PS-2152-2H,interface IEC 320-C14) Current
02131725900W platinumAC power supply(model PAC900S12-BW,interface IEC 320-C14) Current
021317302000W platinumAC power supply(model PAC2000S12-BW,interface IEC 320-C14) Current
02312YKRserver platinum 2000W 2.0 versionAC power supply(model PAC2000S12-B1,interface IEC 320-C14) Current
02313FNCserver platinum 1500W 2.0 versionAC power supply(model PAC1500S12-B1,interface IEC 320-C14) Current
02313XSFserver platinum 900W 2.0 versionAC power supply-ST(model PAC900S12-B2,interface IEC 320-C14) Current
0231Y019server platinum 2000W 2.0 versionAC power supply(model PAC2000S12-B1,interface IEC 320-C14) Current
0231Y021HVDC1500WB power supply module(model PHD1500S12-B2,interface Rongfeng RF-203 high-voltage input terminal) Current
0231Y025server titanium 2000W AC power supply module(model PAC2000S12-T1,interface IEC 320-C14) Current
0231Y033server platinum 1500W 2.0 versionAC power supply(model PAC1500S12-B1,interface IEC 320-C14) Current
02312DEQHVDC1500WB power supply module(model PHD1500S12-B2,interface Rongfeng RF-203 high-voltage input terminal) EOM
02312GEQ1500W platinum high-voltage DC_power supply module(incl. DC_power cord)(model PDC1500S1201,interface Phoenix SPT 5/3-H-7,5-ZB model crimp terminal) EOP
02312HGY2000W AC power supply module(model PAC2000S12-BG,interface IEC 320-C14) EOM
02312XWKserver platinum 900W 2.0 versionAC power supply(model PAC900S12-B2,interface IEC 320-C14) EOM
0231Y017server platinum 900W 2.0 versionAC power supply(model PAC900S12-B2,interface IEC 320-C14) EOM
02312DAEFunction Module,PAC1500S12-BE,PAC1500S12-BE,Server Platinum 1500W power supply EOP Field replaceable
02311TLFFunction Module,PAC900S12-BE,PAC900S12-BE,PAC900S12-BE AC power supply unit EOP Field replaceable
02312BLLFunction Module,PDC1200S12-CE,PDC1200S12-CE,PDC1200S12-CE DC power supply unit EOP Field replaceable
02312HDFFunction Module,AC-DC POWER SUPPLY,PHD1500S12-B1,5degC,55degC,180-305Vac,260-400Vdc,12V/125A,Server HVDC (High Voltage DC) 1500W Platinum Power Supply,68*183*40 EOP Field replaceable
02270171DC-DC Module,1500W,5degC,55degC,260V,400V,12V/125A,1A,22000uF Current Field replaceable
02312AHKFunction Module,PAC2000S12-BE,PAC2000S12-BE,Function Module,PAC2000S12-BE,PAC2000S12-BE,Server Platinum 2000W,power supply EOP Field replaceable
03024XCJManufactured Board,2488H V5,BC62PBPE,Power BackPlane board,1*2 EOP Field replaceable
06410471Other Server Accessories,Manufactured Board,BP24H V5,BC62PBPE,Power BackPlane board,1*2,Chinese and English doc EOP Field replaceable
02312GQAFunction Module,AC-DC,PAC2000S12-BE,Server Platinum 2000W AC power supply-India Item only EOP Field replaceable
P/NDescription / SpecificationStatus
02313EKDfunction module-Public Module-M.2 SSD-SATA 6Gb/s-64GB-M.2-B-M-2242-22mm*42mm(hot-swappable) Current
0255Y695SSD module-Servers-M.2 SSD-SATA 6Gb/s-240GB-80.0mm * 22.0mm * 3.58 mm(hot-swappable)-ER3 series Current
0255Y697SSD module-Servers-M.2 SSD-SATA 6Gb/s-480GB-80.0mm * 22.0mm * 3.58 mm(hot-swappable)-ER3 series Current
0255YFBASSD module-Servers-M.2 SSD-SATA 6Gb/s-480GB-80.0mm * 22.0mm * 3.58 mm(hot-swappable)-ER3 series Current
02312ACWfunction module-Public Module-BC1M01M2FRU-M.2 SSD-SATA 6Gb/s-240GB-80.0mm * 22.0mm * 3.58 mm(hot-swappable) EOP
02312BLQfunction module-Public Module-BC1M02M2FRU-M.2 SSD-SATA 6Gb/s-32GB-22mm*42mm(hot-swappable) EOP
02312CGLfunction module-2488 V5-BC6M05LCD-LCD panel assembly-3.5 inch industrial touch serial display-resolution:320*240-Chinese documentation EOM
02312KGRfunction module-Public Module-BC1M07M2FRU-M.2 SSD-SATA 6Gb/s-64GB-M.2-B-M-2242-22mm*42mm(hot-swappable) EOP
02312LKBfunction module-Public Module-BC1M08M2FRU-M.2 SSD-240GB SATA 6Gb/s-80.0mm * 22.0mm * 3.58 mm(hot-swappable) EOP
02312MCFfunction module-Public Module-BC1M09M2FRU-M.2 SSD-SATA 6Gb/s-480GB-80.0mm * 22.0mm * 3.58 mm(hot-swappable) EOP
02312XGPfunction module-Public Module-ER2GD240GM2-M.2 SSD-SATA 6Gb/s-240GB-80.0mm * 22.0mm * 3.58 mm(hot-swappable) EOP
02312XKGfunction module-Public Module-ER2GD480GM2-M.2 SSD-SATA 6Gb/s-480GB-80.0mm * 22.0mm * 3.58 mm(hot-swappable) EOP
02313ARCfunction module-Public Module-M.2 SSD-SATA 6Gb/s-240GB-80.0mm * 22.0mm * 3.58 mm(hot-swappable) EOM
02313ARHfunction module-Public Module-M.2 SSD-SATA 6Gb/s-480GB-80.0mm * 22.0mm * 3.58 mm(hot-swappable) EOM
90010339Liquid Manufactory Auxiliaries,Thermal Grease,X-23-7868-2D,Thermal Conductivity 3.6W/mK / 6.0W/mK,2g,Gap filling thermal conductive for customer use,1ml Current Engineer replace
03023RJVManufactured Board,2288H V5,BC11RCIC,Right Customer Interface Board,6*2 EOP Engineer replace
06020088DVDRW-CD 24X/DVD 8X,USB2.0,External,USB 2.0 5V power Current Engineer replace
06020105CD-ROM Driver,DVD-RW,CD 24X/DVD 8X,SATA,9.5*128*126.1mm,inside,SATA,5V Power,include front panel Current Engineer replace
03024AFTManufactured Board,2288H V5,BC11VGAC,2U Eight Hard VGA Card EOP Engineer replace
02312LAXFunction Module,2288H V5,BC6M06LCD,LCD module,3.5 inch TFT LCD touchscreen,320*240,Chinese documnet EOP Engineer replace
03029XSYManufactured Board,2488H V5,BC62MBHAA,2488H V5 Mainboard,custommb,Board ID 0X03,1*1 EOP Field replaceable
03024HQLManufactured Board,BC62LCIA,left Customer Interface Board,6*2 EOP Engineer replace
02311YHHFunction Module,2488H V5,BC6M01PRNB,PCIe Riser Card,2 slot(x16,x8),used for 2488H V5(Support Full High,Half Length) EOP Engineer replace
02311YHJFunction Module,2488H V5,BC6M02PRNB,PCIe Riser Card,2 slot(x16,x8),used for 2488H V5(Support Full High, 3/4 Length) EOP Engineer replace
P/NDescription / SpecificationStatus
04052259Power cord,China AC Power 250V2.5A,2.0m,PISM,227IEC53-0.75^2(3C),C5SF,250V,2.5A,Black Current Engineer replace
04051080Power cord,South Africa AC Power 250V10A,3m,PMAM,H05VV-F-1.0mm^2(3C),C13SF,250V,10A,Black Current Engineer replace
04041119Power Cable,Switzerland AC Power Cable 250V10A,3.0m,PJSM ,H05VV-F-1.0mm^2(3C),C13SF,Black Current Engineer replace
04050517Power Cable,China AC Power Cable 250V10A,2.0m,PISM,227IEC53(RVV)1.0mm^2(3C),C13SF,Black Current Engineer replace
0415G005Power cord,China AC Power 250V10A,2.0m,C14SM,227IEC53-1.0^2(3C),C13SF,PDU Cable Current Engineer replace
0405G02CPower Cords Cable,China AC Power 250V10A,0.8m,C14SM,227IEC53 1.0^2(3C),C13SF,PDU Cable Current Engineer replace
0405G02DPower Cords Cable,Japan AC Power 250V12A,1.8m,C14SM,HVCTF 1.25^2(3C),C13SF,PDU Cable Current Engineer replace
04050955Power Cords Cable,China AC Power,250V10A,1.5m,PISM,227IEC53(RVV)1.0mm^2(3C),C13SF,250V,10A,Black Current Engineer replace
0405G02FPower Cords Cable,Australia AC Power 250V10A,1.8m,C14SM,H05VV-F-1.0^2(3C),C13SF,PDU Cable Current Engineer replace
04041117Power Cable,Britain AC Power Cable 250V10A,3.0m,PGAM ,H05VV-F-1.0mm^2(3C),C13AF-L,Black Current Engineer replace
04051922IT Equipment Cable,Signal Cable,0.7m,H2X10(2.0),8*UL1571 28AWG,H2X4(2.0),With Latch EOP Engineer replace
0405G02HPower Cords Cable,Korea AC Power 250V10A,1.8m,C14SM,H05VV-F-1.0^2(3C),C13SF,PDU Cable Current Engineer replace
0405G02KPower Cords Cable,Denmark AC Power 250V10A,3m,PKSM,H05VV-F-3*1.0^2(3C),C13SF,Black Current Engineer replace
0405G028Power Cords Cable,Korea AC Power 250V10A,3m,PFSM,H05VV-F 3*1.0^2(3C),C13SF,Black Current Engineer replace
04050588Power cord,China AC Power Cable250V10A,1.5 m,C14SM,(227IEC53(RVV)1.0mm^2(3C)),C13SF,250V,10A,White,PDU Cable Current Engineer replace
0405G029Power Cords Cable,North America AC Power 250V10A,1.8m,C14SM,SJT 18AWG(3C),C13SF,PDU Cable Current Engineer replace
04050784Power Cords Cable,China AC Power Cable,250V16A,2m,C14SM,227IEC53-1.0^2(3C),C13SF,Yellow Current Engineer replace
04051035Power cord,India AC Power 250V6A,3m,PM-IIAM,IS 694-1.0^2(3C),C13 SF,250V,6A,Black Current Engineer replace
04050188Power Cords Cable,China AC Power 250V10A,1.5m,C14SM,227IEC53(RVV)1.0mm^2(3C),C13SF,PDU Cable Current Engineer replace
04020728Power Cable,America AC Power Cable,125V10A,3.0m,PBSM,18SJT(3C),C13SF,Black Current Engineer replace
04042698Power Cords Cable,China AC Power 250V10A,15.0m,PISM,227IEC53-1.0^2(3C),C13SF,Black Current Engineer replace
04042697Power Cords Cable,China AC Power 250V10A,10.0m,PISM,227IEC53-1.0^2(3C),C13SF,Black Current Engineer replace
04042699Power Cords Cable,China AC Power 250V10A,20.0m,PISM,227IEC53-1.0^2(3C),C13SF,Black Current Engineer replace
04041120Power Cable,Italy AC Power Cable 250V10A,3.0m,PLSM,H05VV-F-1.0mm^2(3C),C13SF,Black Current Engineer replace
04047785Power Cords Cable,Argentina AC Power 250V10A,3.0m,PISM,H05VV-F-1.0mm^2(3C),C13SF,Black Current Engineer replace
04051020High Speed Cable,Internal Mini SAS HD Cable,0.75m,Internal Mini SAS HD R/A,8*(1P*30AWG+ 2*Drain)+8C*30AWG,Internal Mini SAS HD STR,R/A-STR Current Engineer replace
04052137Power cord,Taiwan AC 125V11A,3.0m,PBSM,HVCTF 3*1.25mm2,C13SF,125V,11A,Black,BSMI Current Engineer replace
04040888Power Cords Cable,Australia AC Power Cable,250V 10A,3.0m,PISM,H05VV-F-1.0mm^2(3C),C13SF,Black Current Engineer replace
04040889Power cord,BS546 250V10A,3.0m,PM-IAM,H05VV-F-1.5mm^2(3C),C13SF,250V,10A,Black Current Engineer replace
0405G019Power Cords Cable,Europe AC 250V10A,1.8m,C14SM,H05VV-F- 3*1.00^2,C13SF,PDU Cable Current Engineer replace
04050373Power cord,China AC Power Cable250V10A,1.0m,C14SM,(227IEC53(RVV)-1.0mm^2(3C)),C13SF,Black,PDU Cable Current Engineer replace
04041056Power cord,Europe AC Power Cable,250V10A,3.0m,PFSM,(H05VVF 1.0^2(3C)),C13SF,250V,10A,BLack Current Engineer replace
04050139Power Cords Cable,China AC Power Cable,250V10A,3m,PISM,227IEC53-1.0^2(3C),C13SF,Black Current Engineer replace
04150258Power Cable,Brazil AC Power Cable 250V10A,3.0m,PNSM ,H05VV-F-1.0mm^2(3C),C13SF,Black Current Engineer replace
04040887Power Cable,Japan AC Power Cable 125V12A,3.0m,PBSM,HVCTF-1.25mm^2(3C),C13SF,Black Current Engineer replace
14130923Optical Cable Parts,MPO/PC,MPO/PC,MULTI-MODE,15m,8 CORES,0m/0m,GJFH-8A1A.2(OM3),3.5MM,LSZH,60mm MPO,Bending insensitive Current Engineer replace
04050847Power cord,China AC Power Cable,250V10A,6.0m,C14SM,(227IEC53-1.0^2(3C)),C13SF,250V,10A,Black,PDU Cable Current Engineer replace
04051858Power cord,China AC Power Cable 250V10A,3.0m,PISM,227IEC53-1.0^2(3C),C13SF,250V,10A,Yellow Current Engineer replace
04041104Power Cords Cable,China AC Power 250V10A,3.0m,PISM,227IEC53-1.0^2(3C),C13SF,Black Current Engineer replace
04050846Power cord,China AC Power Cable,250V10A,3.0m,C14SM,(227IEC53-1.0^2(3C)),C13SF,250V,10A,Black,PDU Cable Current Engineer replace
04050206Power Cable,China AC Power Cable 250V10A,1.0m,PISM,227IEC53(RVV)1.0mm^2(3C),C13SF,Black Current Engineer replace
04040890Power Cable,Britain AC Power Cable 250V10A,3.0m,PGAM ,H05VV-F-1.0mm^2(3C),C13SF,Black Current Engineer replace
04051021High Speed Cable,Internal Mini SAS HD Cable,0.85m,Internal Mini SAS HD R/A,8*(1P*30AWG+ 2*Drain)+8C*30AWG,Internal Mini SAS HD STR,R/A-STR Current Engineer replace
04051390High Speed Cable,Internal Mini SAS HD Cable,0.95m,Internal Mini SAS HD R/A,8*(1P*30AWG+ 2*Drain)+8C*30AWG,Internal Mini SAS HD STR,R/A-STR Current Engineer replace
04051403High Speed Cable,100G EDR QSFP28 Passive High Speed Cable,1m,QSFP28,CC8P0.4B(S),QSFP28,IB-Mellanox,LSZH Current Engineer replace
04051404High Speed Cable,100G EDR QSFP28 Passive High Speed Cable,3m,QSFP28,CC8P0.4B(S),QSFP28,IB-Mellanox,LSZH Current Engineer replace
0405Y011High Speed Cable,25G SFP28 Passive High Speed Cable,3m,SFP28,CC2P0.254B(S),SFP28 Current Engineer replace
0405Y010High Speed Cable,25G SFP28 Passive High Speed Cable,1m,SFP28,CC2P0.254B(S),SFP28 Current Engineer replace
0405Y008High Speed Cable,10G Passive SFP+ Cable,1m,(SFP+20M),(CC2P0.254B),(SFP+20M),LSFRZH For Indoor,ETH 10GbE,LSZH Current Engineer replace
0405Y007High Speed Cable,10G SFP+ High Speed Cable,3m,SFP+20M,CC2P0.254B(S),SFP+20M,LSFRZH For Indoor,ETH 10GbE,LSZH Current Engineer replace
04151188Power Cable,1.5m,HVDC Straight Female,227IEC53(RVV)1.0mm^2(3C) Current Engineer replace
04050233High Speed Cable,10G Passive SFP+ Cable,1m,(SFP+20M),(CC2P0.254B),(SFP+20M),LSFRZH For Indoor,ETH 10GbE,Y Current Engineer replace
04051942High Speed Cable,Intel Omni-Path Passive Copper Cable 100Gbps,1.0m,QSFP28,30AWG*8P,QSFP28,Only for HPC adaptive with Intel switches EOP Engineer replace
04051944High Speed Cable,Intel Omni-Path Passive Copper Cable 100Gbps,3.0m,QSFP28,26AWG*8P,QSFP28,Only for HPC adaptive with Intel switches EOP Engineer replace
04051943High Speed Cable,Intel Omni-Path Passive Copper Cable 100Gbps,2.0m,QSFP28,26AWG*8P,QSFP28,Only for HPC adaptive with Intel switches EOP Engineer replace
04051353High Speed Cable,25G SFP28 Passive High Speed Cable,3m,SFP28,CC2P0.254B(S),SFP28 Current Engineer replace
04050694High Speed Cable,FDR High Speed Cable-56Gbps,3m,QSFP+38M,CC8P0.32B(S),QSFP+38M,Indoor EOP Engineer replace
04050693High Speed Cable,FDR High Speed Cable-56Gbps,1m,QSFP+38M,CC8P0.254B(S),QSFP+38M EOP Engineer replace
0405Y019High Speed Cable,HS Cable Slimline-2*mini SAS HD,1.0m&0.9m,Slimline X8 STR,2*((31AWG*1Pair+31AWG*2Drain)*8+31AWG*1Pair*4),2*Internal mini SAS HD R/A,Slimline-2*mini SAS HD Current Engineer replace
04150441Power Cable,3.5m,4mm^2,2*T4^2GY,H07Z-K-4^2BL+H07Z-K-4^2B,2*T4^2GY,LSZH Current Engineer replace
04152464Power Cable,0.5m,4mm^2,(OT6-4),(H07Z-K-4^2G&Y),(OT6-6),LSZH,YES Current Engineer replace
04080606Monitor&Alarm Cable,NCSI Signal Cable,0.16m,H2X10(2.0),12*UL1685 28AWG,H2X6(2.0),With Hook Current Engineer replace
04052010IT Equipment Cable,Signal Cable,0.3m,(H2X10(2.0)),(20*UL1571 28AWG),(H2X10(2.0)),With Latch and latch pull EOP Engineer replace
04051924IT Equipment Cable,VGA Signal Cable,0.35m,H2X6(2.0),2P*28AWG+8C*28AWG,H2X6(2.0),With Latch EOP Engineer replace
04051036IT Equipment Cable,NCSI signal wire,0.15m,H2X6(2.0),2P*28AWG+8C*28AWG,H2X6(2.0),Latchup Current Engineer replace
04051352High Speed Cable,25G SFP28 Passive High Speed Cable,1m,SFP28,CC2P0.254B(S),SFP28 Current Engineer replace
04050689High Speed Cable,CD-ROM Cable,0.75m,Slim SATA13 STR,2P*30AWG+3*UL1007 22AWG,SATA7 STR+H4(5.08),Hybird Calbe Current Engineer replace
04152145Power Cable,0.6m,H2X7(3.0),2*18UL2651(8C)B(Flat),H2X7(3.0) Current Engineer replace
04051923IT Equipment Cable,Signal Cable,0.3m,H2x10(1.25),20*UL1571 28AWG,H2X10(2.0) EOP Engineer replace
04152142Power Cable,0.45m,H2X10(3.0),2*18UL2651(12C)B(Flat),H2X10(3.0) EOP Engineer replace
04080588Monitor&Alarm Cable,Signal Cable,0.3m,H2X10(2.0),20*UL1685 28AWG,H2X10(2.0),shield EOP Engineer replace
04052081High Speed Cable,Mini SAS HD (PCIe) NVMe Y Cable,0.9m&0.9m,2*Mini SAS HD RA,10*(9*(30AWG*1P+Drain*2))+2*(30AWG*4C),Mini SAS HD 8i STR,Only for 8*NVMe backplane EOP Engineer replace
P/NDescription / SpecificationStatus
02311WGDFunction Module,2488 V5,BC6M02FAN,8038 Plus Fan module EOP Field replaceable

Operating System Compatibility

Operating SystemVersion / KernelRelease
Asianux Server 7.33.10.0-514.axs7.x86_64Asianux Server 7.3 for Intel EM64T
Asianux Server 7.63.10.0-957.axs7.x86_64Asianux Server 7.6 for Intel EM64T
BC-Linux V7.64.19.25-200.el7.bclinux.x86_64Big Cloud Linux 7.6 for Intel EM64T
BC-Linux V7.75.4.18-200.el7.bclinux.x86_64Big Cloud Linux 7.7 for Intel EM64T
BC-Linux V7.85.4.18-200.el7.bclinux.x86_64Big Cloud Linux 7.8 for Intel EM64T
BC-Linux V8.15.4.67-300.el8.bclinux.x86_64BigClould Enterprise Linux 8.1
BC-Linux V8.25.10.0-200.el8_2.bclinux.x86_64BigClould Enterprise Linux 8.2
BC-Linux V8.45.10.84-310.5.el8.bclinux.x86_64BigClould Enterprise Linux 8.4
BC-Linux V8.65.10.134-12.2.el8.bclinux.x86_64BigClould Enterprise Linux 8.6
BC-Linux for Euler V21.104.19.90-2107.6.0.0100.oe1.bclinux.x86_64BigClould Enterprise Linux For Euler 21.10 LTS
CentOS 6.102.6.32-754.el6 x86_64CentOS Linux 6 Update 10 Server for Intel EM64T
CentOS 6.92.6.32-696.el6 x86_64CentOS Linux 6 Update 9 Server for Intel EM64T
CentOS 7.33.10.0-514.el7.x86_64CentOS Linux 7 Update 3 Server for Intel EM64T
CentOS 7.43.10.0-693.el7.x86_64CentOS Linux 7 Update 4 Server for Intel EM64T
CentOS 7.53.10.0-862.el7.x86_64CentOS Linux 7 Update 5 Server for Intel EM64T
CentOS 7.63.10.0-957.el7.x86_64CentOS Linux 7 Update 6 Server for Intel EM64T
CentOS 7.73.10.0-1062.el7.x86_64CentOS Linux 7 Update 7 Server for Intel EM64T
CentOS 7.83.10.0-1127.el7.x86_64CentOS Linux 7 Update 8 Server for Intel EM64T
CentOS 7.93.10.0-1160.el7.x86_64CentOS Linux 7 Update 9 Server for Intel EM64T
CentOS 8.04.18.0-80.el8.x86_64CentOS Linux 8 Server for Intel EM64T
CentOS 8.14.18.0-147.el8.x86_64CentOS Linux 8 Update 1 Server for Intel EM64T
CentOS 8.24.18.0-193.el8.x86_64CentOS Linux 8 Update 2 Server for Intel EM64T
CentOS 8.34.18.0-240.el8.x86_64CentOS Linux 8 Update 3 Server for Intel EM64T
CentOS 8.44.18.0-305.3.1.el8.x86_64CentOS Linux 8 Update 4 Server for Intel EM64T
CentOS 8.54.18.0-348.el8.x86_64CentOS Linux 8 Update 5 Server for Intel EM64T
Citrix Hypervisor 8.04.19.0+1Citrix Hypervisor 8.0
Citrix Hypervisor 8.14.19.0+1Citrix Hypervisor 8.1
Citrix Hypervisor 8.24.19.0+1Citrix Hypervisor 8.2 LTSR
Citrix XenServer 7.14.4.0+2Citrix XenServer 7.1 LTSR
Citrix XenServer 7.24.4.0+10Citrix XenServer 7.2
Citrix XenServer 7.34.4.0+10Citrix XenServer 7.3
Citrix XenServer 7.44.4.0+10Citrix XenServer 7.4
Citrix XenServer 7.54.4.0+10Citrix XenServer 7.5
Citrix XenServer 7.64.4.0+10Citrix XenServer 7.6
Debian 10.04.19.0-5-amd64Debian 10.0 for Intel EM64T
Debian 10.104.19.0-17-amd64Debian 10.10 for Intel EM64T
Debian 10.84.19.0-14-amd64Debian 10.8 for Intel EM64T
Debian 11.05.10.0-8-amd64Debian 11.0 for Intel EM64T
Debian 11.55.10.0-18-amd64Debian 11.5 for Intel EM64T
Debian 9.34.9.0-4-amd64Debian 9.3 for Intel EM64T
Debian 9.64.9.0-8-amd64Debian 9.6 for Intel EM64T
Debian 9.94.9.0-9-amd64Debain 9.9 for Intel EM64T
FusionOS 224.19.90-2112.8.0.0131.u32.fos22.x86_64FusionOS 22
Kylin Linux Advanced Server V104.19.90-vhulk2001.1.0.0026.ns7.15.x86_64Kylin Linux Advanced Server V10
Kylin Linux Advanced Server V10 SP14.19.90-17.ky10.x86_64Kylin Linux Advanced Server V10 SP1 for Intel EM64T
Kylin Linux Advanced Server V10 SP24.19.90-24.4.v2101.ky10.x86_64Kylin Linux Advanced Server V10 SP2 for Intel EM64T
Kylin Linux Advanced Server V10 SP34.19.90-52.15.v2207.ky10.x86_64Kylin Linux Advanced Server V10 SP3 for Intel EM64T
Kylin Linux Advanced Server V10 SP3 24034.19.90-89.11.v2401.ky10.x86_64Kylin Linux Advanced Server V10 SP3 2403 for Intel EM64T
NeoKylin Server V6.92.6.32-696.el6 x86_64NeoKylin Linux Advanced Server release V6Update9 for Intel EM64T
NeoKylin Server V7.43.10.0-693.el7.x86_64NeoKylin Linux Advanced Server release V7Update4 for Intel EM64T
NeoKylin Server V7.63.10.0-957.el7.x86_64NeoKylin Linux Advanced Server release V7Update6 for Intel EM64T
OpenStack 10.0Initial Red Hat Enterprise Linux Versions Support: RHEL7.3Red Hat Enterprise Linux OpenStack Platform 10.0 (x86_64)
OpenStack 11.0Initial Red Hat Enterprise Linux Versions Support: RHEL7.3Red Hat Enterprise Linux OpenStack Platform 11.0 (x86_64)
OpenStack 12.0Initial Red Hat Enterprise Linux Versions Support: RHEL7.4Red Hat Enterprise Linux OpenStack Platform 12.0 (x86_64)
OpenStack 13.0Initial Red Hat Enterprise Linux Versions Support: RHEL7.5Red Hat Enterprise Linux OpenStack Platform 13.0 (x86_64)
OpenStack 16.0Initial Red Hat Enterprise Linux Versions Support: RHEL7.6, RHEL8.0Red Hat Enterprise Linux OpenStack Platform 16.0 (x86_64)
Oracle Linux 6.104.1.12-124.16.4.el6uek.x86_64Oracle Linux Release 6 Update 10 for Intel EM64T
Oracle Linux 6.94.1.12-61.1.28.el6uek for V2&V3&V4 CPU ; 4.1.12-112.14.15 for V5 CPUOracle Linux Release 6 Update 9 for Intel EM64T
Oracle Linux 7.34.1.12-61.1.18.el7uek for V2&V3&V4 CPU ; 4.1.12-112.14.15 for V5 CPUOracle Linux Release 7 Update 3 for Intel EM64T
Oracle Linux 7.44.1.12-94.3.9.el7uek for V2&V3&V4 CPU ; 4.1.12-112.14.15 for V5 CPUOracle Linux Release 7 Update 4 for Intel EM64T
Oracle Linux 7.54.1.12-112.16.4.el7uek.x86_64Oracle Linux Release 7 Update 5 for Intel EM64T
Oracle Linux 7.64.14.35-1818.3.3.el7uek.x86_64;4.14.35-1902.0.9 for cascade cpuOracle Linux Release 7 Update 6 for Intel EM64T
Oracle Linux 7.74.14.35-1902.3.2.el7uek.x86_64Oracle Linux Release 7 Update 7 for Intel EM64T
Oracle Linux 7.84.14.35-1902.300.11.el7uek.x86_64Oracle Linux Release 7 Update 8 for Intel EM64T
Oracle Linux 7.95.4.17-2011.6.2.el7uek.x86_64Oracle Linux Release 7 Update 9 for Intel EM64T
Oracle Linux 8.04.18.0-80.el8.x86_64Oracle Linux Release 8 for Intel EM64T
Oracle Linux 8.14.18.0-147.el8.x86_64Oracle Linux Release 8 Update 1 for Intel EM64T
Oracle Linux 8.25.4.17-2011.1.2.el8uek.x86_64Oracle Linux Release 8 Update 2 for Intel EM64T
Oracle Linux 8.35.4.17-2011.7.4.el8uek.x86_64Oracle Linux Release 8 Update 3 for Intel EM64T
Oracle Linux 8.45.4.17-2102.201.3.el8uek.x86_64Oracle Linux Release 8 Update 4 for Intel EM64T
Oracle Linux 8.55.4.17-2136.300.7.el8uek.x86_64Oracle Linux Release 8 Update 5 for Intel EM64T
Oracle Linux 8.65.4.17-2136.307.3.1.el8uek.x86_64Oracle Linux Release 8 Update 6 for Intel EM64T
Oracle Linux 8.75.15.0-3.60.5.1.el8uek.x86_64Oracle Linux Release 8 Update 7 for Intel EM64T
Oracle Linux 9.05.15.0-0.30.19.el9uek.x86_64Oracle Linux Release 9 for Intel EM64T
Oracle Linux 9.15.15.0-3.60.5.1.el9uek.x86_64Oracle Linux Release 9 Update 1 for Intel EM64T
Oracle VM 3.4.44.1.12-32.1.3 for V2&V3& V4 CPU ; 4.1.12-112.14.15 for V5 CPUOracle VM 3.4.4
Oracle VM 3.4.54.1.12-124.14.5Oracle VM 3.4.5
Oracle VM 3.4.64.1.12-124.21.1Oracle VM 3.4.6
RHEL 6.102.6.32-754.el6.x86_64Red Hat Enterprise Linux 6 Update 10 Server for Intel EM64T
RHEL 6.10 KVM2.6.32-754.el6.x86_64Red Hat Enterprise Linux 6 Update 10 Server for Intel EM64T
RHEL 6.92.6.32-696.el6 x86_64Red Hat Enterprise Linux 6 Update 9 Server for Intel EM64T
RHEL 6.9 KVM2.6.32-696.el6 x86_64Red Hat Enterprise Linux 6 Update 9 Server for Intel EM64T
RHEL 7.33.10.0-514.el7.x86_64Red Hat Enterprise Linux 7 Update 3 Server for Intel EM64T
RHEL 7.3 KVM3.10.0-514.el7.x86_64Red Hat Enterprise Linux 7 Update 3 Server for Intel EM64T
RHEL 7.43.10.0-693.el7.x86_64Red Hat Enterprise Linux 7 Update 4 Server for Intel EM64T
RHEL 7.4 KVM3.10.0-693.el7.x86_64Red Hat Enterprise Linux 7 Update 4 Server for Intel EM64T
RHEL 7.53.10.0-862.el7.x86_64Red Hat Enterprise Linux 7 Update 5 Server for Intel EM64T
RHEL 7.5 KVM3.10.0-862.el7.x86_64Red Hat Enterprise Linux 7 Update 5 Server for Intel EM64T
RHEL 7.63.10.0-957.el7.x86_64Red Hat Enterprise Linux 7 Update 6 Server for Intel EM64T
RHEL 7.6 KVM3.10.0-957.el7.x86_64Red Hat Enterprise Linux 7 Update 6 Server for Intel EM64T
RHEL 7.73.10.0-1062.el7.x86_64Red Hat Enterprise Linux 7 Update 7 Server for Intel EM64T
RHEL 7.83.10.0-1127.el7.x86_64Red Hat Enterprise Linux 7 Update 8 Server for Intel EM64T
RHEL 7.93.10.0-1160.el7.x86_64Red Hat Enterprise Linux 7 Update 9 Server for Intel EM64T
RHEL 8.04.18.0-80.el8.x86_64Red Hat Enterprise Linux 8 Server for Intel EM64T
RHEL 8.14.18.0-147.el8.x86.64Red Hat Enterprise Linux 8 Update 1 Server for Intel EM64T
RHEL 8.24.18.0-193.el8.x86_64Red Hat Enterprise Linux 8 Update 2 Server for Intel EM64T
RHEL 8.34.18.0-240.el8.x86_64Red Hat Enterprise Linux 8 Update 3 Server for Intel EM64T
RHEL 8.44.18.0-305.el8.x86_64Red Hat Enterprise Linux 8 Update 4 Server for Intel EM64T
RHEL 8.54.18.0-348.el8.x86_64Red Hat Enterprise Linux 8 Update 5 Server for Intel EM64T
RHEL 8.5 KVM4.18.0-348.el8.x86_64Red Hat Enterprise Linux 8 Update 5 Server for Intel EM64T
RHEL 8.64.18.0-372.9.1.el8.x86_64Red Hat Enterprise Linux 8 Update 6 Server for Intel EM64T
RHEL 8.6 KVM4.18.0-372.9.1.el8.x86_64Red Hat Enterprise Linux 8 Update 6 Server for Intel EM64T
RHEL 8.74.18.0-425.3.1.el8.x86_64Red Hat Enterprise Linux 8 Update 7 Server for Intel EM64T
RHEL 8.7 KVM4.18.0-425.3.1.el8.x86_64Red Hat Enterprise Linux 8 Update 7 Server for Intel EM64T
RHEL 9.05.14.0-70.13.1.el9_0.x86_64Red Hat Enterprise Linux 9 Server for Intel EM64T
RHEL 9.0 KVM5.14.0-70.13.1.el9_0.x86_64Red Hat Enterprise Linux 9 Server for Intel EM64T
RHEL 9.15.14.0-162.6.1.el9_1.x86_64Red Hat Enterprise Linux 9 Update 1 Server for Intel EM64T
RHEL 9.1 KVM5.14.0-162.6.1.el9_1.x86_64Red Hat Enterprise Linux 9 Update 1 Server for Intel EM64T
SLES 11 SP43.0.101-63-defaultSUSE Linux Enterprise Server 11 Service Pack 4 for Intel EM64T
SLES 12 SP24.4.21-69-defaultSUSE Linux Enterprise Server 12 Service Pack 2 for AMD64 & Intel64
SLES 12 SP34.4.73-5-defaultSUSE Linux Enterprise Server 12 Service Pack 3 for AMD64 & Intel64
SLES 12 SP44.12.14-94.41-defaultSUSE Linux Enterprise Server 12 Service Pack 4 for AMD64 & Intel64
SLES 12 SP54.12.14-120-defaultSUSE Linux Enterprise Server 12 Service Pack 5 for AMD64 & Intel64
SLES 154.12.14-23-defaultSUSE Linux Enterprise Server 15 for Intel EM64T
SLES 15 SP14.12.14-195-defaultSUSE Linux Enterprise Server 15 Service Pack 1 for AMD64 & Intel64
SLES 15 SP25.3.18-22-defaultSUSE Linux Enterprise Server 15 Service Pack 2 for AMD64 & Intel64
SLES 15 SP35.3.18-57-defaultSUSE Linux Enterprise Server 15 Service Pack 3 for AMD64 & Intel64
SLES 15 SP45.14.21-150400.22-defaultSUSE Linux Enterprise Server 15 Service Pack 4 for AMD64 & Intel64
SLES 15 SP76.4.0-150700.51-defaultSUSE Linux Enterprise Server 15 Service Pack 7 for AMD64 & Intel64
Ubuntu 14.04.5 LTS4.4.0-31-genericUbuntu 14.04.5 LTS Server Edition for Intel EM64T
Ubuntu 16.04 LTS4.4.0-21-genericUbuntu 16.04 LTS Server Edition for Intel EM64T
Ubuntu 16.04.2 LTS4.4.0-62-genericUbuntu 16.04.2 LTS Server Edition for Intel EM64T
Ubuntu 16.04.5 LTSGA:4.4.0-131-generic;HWE:4.15.0-38-genericUbuntu 16.04.5 LTS Server Edition for Intel EM64T
Ubuntu 18.04 LTS4.15.0-20-genericUbuntu 18.04 LTS Server Edition for Intel EM64T
Ubuntu 18.04.1 LTS4.15.0-29-genericUbuntu 18.04.1 LTS Server Editon for Intel EM64T
Ubuntu 18.04.2 LTS4.15.0-45-genericUbuntu 18.04.2 LTS Server Editon for Intel EM64T
Ubuntu 18.04.3 LTS4.15.0-55-genericUbuntu 18.04.3 LTS Server Editon for Intel EM64T
Ubuntu 18.04.4 LTS4.15.0-76-genericUbuntu 18.04.4 LTS Server Editon for Intel EM64T
Ubuntu 18.04.5 LTSGA: 4.15.0-112-generic HWE: 5.4.0.42Ubuntu 18.04.5 LTS Server Editon for Intel EM64T
Ubuntu 18.04.6 LTS4.15.0-156-genericUbuntu 18.04.6 LTS Server Editon for Intel EM64T
Ubuntu 20.04 LTS5.4.0-26-genericUbuntu 20.04 LTS Server Edition for Intel EM64T
Ubuntu 20.04.1 LTS5.4.0-42-genericUbuntu 20.04.1 LTS Server Edition for Intel EM64T
Ubuntu 20.04.5 LTS5.4.0-125-genericUbuntu 20.04.5 LTS Server Edition for Intel EM64T
Ubuntu 22.04 LTS5.15.0-25-genericUbuntu 22.04 LTS Server Edition for Intel EM64T
Ubuntu 22.04.1 LTS5.15.0-43-genericUbuntu 22.04.1 LTS Server Edition for Intel EM64T
VMware ESXi 6.0 U3Build 5050593VMware ESXi 6.0 update 3 for Intel EM64T
VMware ESXi 6.5Build 4564106VMware ESXi 6.5 for Intel EM64T
VMware ESXi 6.5 U1Build 5969303VMware ESXi 6.5 update 1 for Intel EM64T
VMware ESXi 6.5 U2Build 8294253VMware ESXi 6.5 Update 2 for Intel EM64T
VMware ESXi 6.5 U3Build-13932383VMware ESXi 6.5 Update 3 for Intel EM64T
VMware ESXi 6.7Build 8169922VMware ESXi 6.7 for Intel EM64T
VMware ESXi 6.7 U1Build 10302608VMware ESXi 6.7 Update 1 for Intel EM64T
VMware ESXi 6.7 U2build 13006603VMware ESXi 6.7 Update 2 for Intel EM64T
VMware ESXi 6.7 U3Build-14320388VMware ESXi 6.7 Update 3 for Intel EM64T
VMware ESXi 7.0build-15525992VMware ESXi 7.0 for Intel EM64T
VMware ESXi 7.0 U1build-16850804VMware ESXi 7.0 Update 1 for Intel EM64T
VMware ESXi 7.0 U2build-17630552VMware ESXi 7.0 Update 2 for Intel EM64T
VMware ESXi 7.0 U3build-18644231VMware ESXi 7.0 Update 3 for Intel EM64T
VMware ESXi 8.0build-20513097VMware ESXi 8.0 for Intel EM64T
VMware ESXi 8.0 U1build-21495797VMware ESXi 8.0 Update 1 for Intel EM64T
VMware ESXi 8.0 U3build-24022510VMware ESXi 8.0 Update 3 for Intel EM64T
VMware ESXi 9.1build-25370933VMware ESXi 9.1 for Intel EM64T
Windows Server 2012 R2Build 9600Microsoft Windows Server 2012 R2 x64
Windows Server 2012 R2 Hyper-VBuild 9600Microsoft Windows Server 2012 R2 Hyper-V x64
Windows Server 2016Build 14393Microsoft Windows Server 2016 x64
Windows Server 2016 Hyper-VBuild 14393Microsoft Windows Server 2016 Hyper-V x64
Windows Server 2019Build 17763Microsoft Windows Server 2019 x64
Windows Server 2019 Hyper-VBuild 17763Microsoft Windows Server 2019 Hyper-V x64
Windows Server 2022Build 20348Microsoft Windows Server 2022 x64
Windows Server 2022 Hyper-VBuild 20348Microsoft Windows Server 2022 Hyper-V x64
openEuler 20.03 LTS4.19.90-2003.4.0.0036.oe1.x86_64openEuler 20.03 LTS
openEuler 20.03 LTS SP14.19.90-2012.5.0.0054.oe1.x86_64openEuler 20.03 LTS SP1
openEuler 20.03 LTS SP24.19.90-2106.3.0.0095.oe1.x86_64openEuler 20.03 LTS SP2 (powered by openEuler)
openEuler 20.03 LTS SP34.19.90-2112.8.0.0131.oe1.x86_64openEuler 20.03 LTS SP3 (powered by openEuler)
openEuler 22.03 LTS5.10.0-60.18.0.50.oe2203.x86_64openEuler 22.03 LTS (powered by openEuler)
openEuler 22.03 LTS SP15.10.0-136.12.0.86.oe2203sp1.x86_64openEuler 22.03 LTS SP1 (powered by openEuler)

Configuring, expanding or replacing this server? Send us your part list or BOM for a fast quotation.

Request a Quote

Selecting components for the 2488H V5

These points from the matrix matter when configuring or expanding a unit:

  • Choose the processor to the workload. Validated options include from the Gold 5115 to high-end options such as the Platinum 8280M, with up to 28 cores per socket.
  • Memory: DDR4 RDIMMs from 8GB to 512GB at up to 3200 MT/s. Give us your capacity target and we will confirm the supported DIMM population and channel rules.
  • RAID levels follow the controller. The validated controllers support RAID 0, 1, 5, 6, 10, 50, 60, JBOD. Cacheless entry cards suit boot and mirroring; cached cards with a supercapacitor enable parity RAID for data arrays; JBOD/IT cards provide passthrough to software RAID.
  • Storage mix. Validated options include SAS/SATA drives up to 15 TB and PCIe NVMe SSDs up to 8 TB. Backplane and tray variants are listed separately under Drive Backplanes.
  • Networking from 100GbE to 25GbE. OCP 3.0 and PCIe adapters are validated for the listed speeds; some SKUs include optical modules and others do not, so check the part description.
  • Power: 900–2000W supplies. Platinum and titanium-rated AC units are listed, with redundant pairs for high availability; confirm the rating your GPU and drive population require.

Reference workload profiles

These profiles show how validated components combine; each is configured and quoted to order.

  • Virtualization / private cloud: balanced processors, a large RDIMM footprint, hardware RAID with cache and redundant power.
  • Database / in-memory: high-frequency processors, maximum memory, PCIe NVMe for log and hot data.
  • All-flash node: parity-capable RAID or HBA, a full set of NVMe SSDs, high-wattage titanium PSU.
  • Storage / backup node: cached RAID or JBOD passthrough, a full set of high-capacity drives, high-wattage PSU.
  • General application / infra: mid-bin processors, moderate memory and storage, cost-effective networking.

The 2488H V5 in the FusionServer range

The numbered FusionServer generations make it straightforward to choose between current and supported hardware. The 2488H V5 is a V5 platform: 1st/2nd Generation Intel Xeon Scalable, DDR4, PCIe 3.0.

We supply new systems with manufacturer warranty and can source validated parts for earlier generations when a budget, software-licensing or support window calls for them. Ask us which generation fits.

2488H V5 — compatibility FAQ

Which processors does the 2488H V5 support?

The matrix lists from the Gold 5115 to high-end options such as the Platinum 8280M, with up to 28 cores per socket. Confirm the thermal and power envelope for your chassis and PSU before ordering.

What memory can I install?

Validated DDR4 RDIMMs range from 8GB to 512GB at up to 3200 MT/s. Tell us your capacity target and we will confirm the supported DIMM population.

Which RAID levels are supported?

Validated controllers support RAID 0, 1, 5, 6, 10, 50, 60, JBOD. Choose a cached card with a supercapacitor for parity RAID (5/6/50/60), an entry card for 0/1/10, or an IT/JBOD card for software RAID passthrough.

What drives are validated?

The matrix lists SAS/SATA drives up to 15 TB and NVMe SSDs up to 8 TB. See the Hard Drives and NVMe tabs for the full list, form factors and current status.

What network speeds are supported?

Validated OCP and PCIe adapters cover 100GbE, 10GbE, 25GbE. Note whether a SKU includes optical modules; we can supply matched optics if required.

What power supplies are available?

The list runs from 900W to 2000W in platinum and titanium ratings. Redundant pairs can be configured for high availability; size the PSU to your CPU, GPU and drive load.

Which operating systems are certified?

The OS matrix lists 166 certified builds, including Red Hat Enterprise Linux, SUSE Linux Enterprise Server, Ubuntu, VMware ESXi, Windows Server, openEuler, each with its exact kernel or build string. Additional builds can often be confirmed on request.

What do the lifecycle statuses mean?

Current/GA parts are in production; PILOT and DEVELOP parts are under limited rollout or qualification; EOM parts are out of marketing but supported as spares. Prefer Current parts for new builds.

Can you supply the server or just parts?

Both. We configure complete systems and supply every validated component listed here with warranty. Send a part list or BOM for a fast quotation.

Request a Quote  Look up a part number  All xFusion models

Leave a message