The FusionServer G8550 V8 is an accelerator-optimised server built around multiple GPUs with high-power cooling and high-speed interconnect. It is a GPU/AI compute platform, designed for AI training and inference, scientific computing, GPU virtualization and graphics workloads. The platform runs on Intel Xeon 6 (Granite Rapids / Sierra Forest) with DDR5 memory and PCIe 5.0 expansion.
Below is the verified compatibility matrix for this model: 57 validated line items across 11 component categories and 13 certified operating-system builds, taken from xFusion’s official compatibility data and presented in English. Every part number listed is published by xFusion for this chassis; nothing is guessed or cross-filled from other models.
Compatibility matrix
Browse validated parts by category using the tabs below. Each tab shows its item count; search inside a tab by part number or keyword, and expand the full list. Parts marked Current are actively orderable; life-cycle parts are still supported and often available as spares. The OS table lists the exact certified kernel or build.
| P/N | Description / Specification | Status |
|---|---|---|
| 4102Y152 | X86 series-OLGA6096-2700MHz-0.55V/1.5V-64bit-500000mW-AMD EPYC 9005 Series-Turin 9755-128Core | Current |
| 4102Y153 | X86 series-OLGA6096-2600MHz-0.55V/1.5V-64bit-400000mW-AMD EPYC 9005 Series-Turin 9655-96Core | Current |
| 4102Y155 | X86 series-OLGA6096-3300MHz-0.55V/1.5V-64bit-400000mW-AMD EPYC 9005 Series-Turin 9575F-64Core | Current |
| 4102Y156 | X86 series-OLGA6096-3200MHz-0.55V/1.5V-64bit-360000mW-AMD EPYC 9005 Series-Turin 9555-64Core | Current |
| 4102Y168 | X86 series-OLGA6096-3650MHz-0.55V/1.5V-64bit-400000mW-AMD EPYC 9005 Series-Turin 9475F-48Core | Current |
| 4102Y173 | X86 series-OLGA6096-3150MHz-0.55V/1.5V-64bit-300000mW-AMD EPYC 9005 Series-Turin 9455-48Core | Current |
| 4102Y173-001 | X86 series-OLGA6096-3150MHz-0.55V/1.5V-64bit-300000mW-AMD EPYC 9005 Series-Turin 9455-48Core | Current |
| 4102Y224-A01 | X86 series-OLGA6096-3300MHz-0.55V/1.5V-64bit-400000mW-AMD EPYC 9005 Series-Turin 9A75-64Core | Current |
| 90010339 | Liquid Manufactory Auxiliaries,Thermal Grease,X-23-7868-2D,Thermal Conductivity 3.6W/mK / 6.0W/mK,2g,Gap filling thermal conductive for customer use,1ml | Current |
| P/N | Description / Specification | Status |
|---|---|---|
| 0251Y288 | memory module-2288H V7-M564R64-generic memory-DDR5-RDIMM-64GB-288pin-0.312ns-6400000KHz-1.1V-ECC-2Rank(4G*4bit)-overseas dedicated | Current |
| 0251Y289 | memory module-2288H V7-M564R96-generic memory-DDR5-RDIMM-96GB-288pin-0.312ns-6400000KHz-1.1V-ECC-2Rank(6G*4bit)-3-way OEM code_overseas dedicated | Current |
| 0251Y290 | memory module-2288H V7-M564R128-generic memory-DDR5-RDIMM-128GB-288pin-0.312ns-6400000KHz-1.1V-ECC-2Rank(8G*4bit)-3-way OEM code_overseas dedicated | Current |
| 0251Y317 | memory module-2288H V7-generic memory-DDR5-RDIMM-64GB-288pin-0.312ns-6400000KHz-1.1V-ECC-2Rank(4G*4bit) | Current |
| 0620Y035 | generic memory-DDR5-RDIMM-128GB-288pin-0.312ns-6400000KHz-1.1V-ECC-2Rank(8G*4bit) | Current |
| 0620Y035-001 | generic memory-DDR5-RDIMM-128GB-288pin-0.312ns-6400000KHz-1.1V-ECC-2Rank(8G*4bit)-Samsung 1bnm | Current |
| 0620Y035-004 | generic memory-DDR5-RDIMM-128GB-288pin-0.312ns-6400000KHz-1.1V-ECC-2Rank(8G*4bit)-designated-model dedicated HYNIX 1bnm | Current |
| 0620Y042 | generic memory-DDR5-RDIMM-64GB-288pin-0.312ns-6400000KHz-1.1V-ECC-2Rank(4G*4bit) | Current |
| 0620Y042-003 | generic memory-DDR5-RDIMM-64GB-288pin-0.312ns-6400000KHz-1.1V-ECC-2Rank(4G*4bit)-Samsung 1bnm | Current |
| 0620Y042-011 | generic memory-DDR5-RDIMM-64GB-288pin-0.312ns-6400000KHz-1.1V-ECC-2Rank(4G*4bit)-CXMT | Current |
| 0620Y043 | generic memory-DDR5-RDIMM-96GB-288pin-0.312ns-6400000KHz-1.1V-ECC-2Rank(6G*4bit) | Current |
| 0620Y043-002 | generic memory-DDR5-RDIMM-96GB-288pin-0.312ns-6400000KHz-1.1V-ECC-2Rank(6G*4bit)-designated-model dedicated HYNIX 1anm | Current |
| 0620Y043-003 | generic memory-DDR5-RDIMM-96GB-288pin-0.312ns-6400000KHz-1.1V-ECC-2Rank(6G*4bit)-designated-model dedicated SAMSUNG 1anm | Current |
| 0620Y043-011 | generic memory-DDR5-RDIMM-96GB-288pin-0.312ns-6400000KHz-1.1V-ECC-2Rank(6G*4bit)-CXMT | Current |
| P/N | Description / Specification | Status |
|---|---|---|
| 0255Y417 | SSD module-Servers-SSD-480GB-SATA 6Gb/s-read-intensive-PM893 series-2.5 inch(2.5 inch bracket)-V7 dedicated | Current |
| 0255Y419 | SSD module-Servers-SSD-960GB-SATA 6Gb/s-read-intensive-PM893 series-2.5 inch(2.5 inch bracket)-V7 dedicated | Current |
| 0255Y421 | SSD module-Servers-SSD-1920GB-SATA 6Gb/s-read-intensive-PM893 series-2.5 inch(2.5 inch bracket)-V7 dedicated | Current |
| 0255Y423 | SSD module-Servers-SSD-3840GB-SATA 6Gb/s-read-intensive-PM893 series-2.5 inch(2.5 inch bracket)-V7 dedicated | Current |
| 0255YDUH | SSD module-Servers-SSD-480GB-SATA 6Gb/s-read-intensive-SE006 series-2.5 inch(2.5 inch bracket)-V7 dedicated | Current |
| 0255YDUM | SSD module-Servers-SSD-960GB-SATA 6Gb/s-read-intensive-SE006 series-2.5 inch(2.5 inch bracket)-V7 dedicated | Current |
| 0255YDUR | SSD module-Servers-SSD-1920GB-SATA 6Gb/s-read-intensive-SE006 series-2.5 inch(2.5 inch bracket)-V7 dedicated | Current |
| 0255YDXA | SSD module-Servers-SSD-3840GB-SATA 6Gb/s-read-intensive-SE006 series-2.5 inch(2.5 inch bracket)-V7 dedicated | Current |
| 0255YEGF | SSD Module,Servers,SSD,3840GB,PCIE 5.0 X4,NVMe PCIe,Read Intensive,R6101 Series,2.5inch(2.5inch Drive Bay),V7 dedicated | Current Field replaceable |
| 0255YDXV | SSD Module,Servers,SSD,7680GB,PCIE 5.0 X4,NVMe PCIe,Read Intensive,R6101 Series,2.5inch(2.5inch Drive Bay),V7 dedicated | Current Field replaceable |
| P/N | Description / Specification | Status |
|---|---|---|
| 0255YCEV-006 | SSD module-Servers-SSD-3840GB-PCIE 5.0 X4-NVMe PCIe-read-intensive-PM9D3a series-2.5 inch(2.5 inch bracket)-V7 dedicated | Current |
| 0255YCEX-007 | SSD module-Servers-SSD-7680GB-PCIE 5.0 X4-NVMe PCIe-read-intensive-PM9D3a series-2.5 inch(2.5 inch bracket)-V7 dedicated | Current |
| 0255YCFQ-003 | SSD module-Servers-SSD-1920GB-PCIE 5.0 X4-NVMe PCIe-read-intensive-PM9D3a series-2.5 inch(2.5 inch bracket)-V7 dedicated | Current |
| 0255YDXV | SSD module-Servers-SSD-7680GB-PCIE 5.0 X4-NVMe PCIe-read-intensive-R6101 series-2.5 inch(2.5 inch bracket)-V7 dedicated | Current |
| 0255YEGF | SSD module-Servers-SSD-3840GB-PCIE 5.0 X4-NVMe PCIe-read-intensive-R6101 series-2.5 inch(2.5 inch bracket)-V7 dedicated | Current |
| 0255Y698 | SSD Module,Servers,M.2 SSD,SATA 6Gb/s-480GB,80.0mm * 22.0mm * 3.58 mm(Non-hot-swappable),ER3 series | Current Field replaceable |
| 0255YCUL | SSD Module,Servers,M.2 SSD,NVMe PCIe,960GB,80.0mm * 22.0mm * 3.58 mm(Non-hot-swappable),PJ1 series | Current Field replaceable |
| 0255Y697 | SSD Module,Servers,M.2 SSD,SATA 6Gb/s-480GB,80.0mm * 22.0mm * 3.58 mm(hot-swappable),ER3 series | Current Field replaceable |
| P/N | Description / Specification | Status |
|---|---|---|
| 0256Y174 | RAID card module-2288H V7-9560-8i 4G-12G SAS RAID card-9560-8i-(SAS3908)-CVPM05-12Gb/s SAS-6Gb/s SATA-PCIe(NVMe)-4G CacheVault-PCIE 4.0 X8-Vendor ID 1000-Device ID 10E2-Subvendor ID 1000-Subdevice ID 4010 | Current |
| 0231Y129 | function module-9560-8i 4G-CN2M95608I4G-9560-8i 4G other board card-12G SAS RAID card-4G cache-8*12Gb/s SAS PHY-1 slimline internal interface-PCIE 4.0 X8-Vendor ID 1000-Device ID 10E2-Subvendor ID 1000-Subdevice ID 4010 | EOM |
| 0817Y002 | Super capacitor module,64mm*51mm*13.1mm,Wire mounting,split from 08170002,NA,7600uF,5h | Current Field replaceable |
| P/N | Description / Specification | Status |
|---|---|---|
| 0231Y809 | function module-Servers-CN2M04ITGG1-XP330 Ethernet adapter-10Gb optical port(Intel X710)-dual-port-SFP+(optical module not included)-half-height half-length(incl. half-height & full-height brackets)-PCIe 3.0 x8 | Current |
| 0257Y102 | PCIe-network adapter-2288H V6-MCX631102AN-ADAT-network adapter-25 GE-64bit-SFP28-2-PCIE 4.0 x8-15b3-101f-2-with driver package | Current |
| 0257Y390 | PCIe-network adapter-2288H V7-MCX75310AAS-NEAT-IB card-Infiniband MCX75310AAS-NEAT-NDR/NDR200/HDR100/EDR IB single-port OSFP-400Gb/s-PCIE 5.0 x16-Vendor ID 15B3-Device ID 1021-1-Subvendor ID 15B3-Subdevice ID 0023-with driver package | Current |
| 0257Y391 | PCIe-network adapter-2288H V7-MCX75310AAS-HEAT-IB card-Infiniband MCX75310AAS-HEAT-200Gb/s NDR200 IB,single-port OSFP-PCIE 5.0 x16-Vendor ID 15B3-Device ID 1021-1-Subvendor ID 15B3-Subdevice ID 0029-with driver package | Current |
| 0257Y476 | PCIe-network adapter-2288H V7-BCM957608-P2200GQF00-network adapter-200 Gigabit-64bit-QSFP56-2 ports-PCIE 5.0 x16-Vendor ID 14e4-Device ID 1760-2-Subvendor ID 14e4-Subdevice ID 9120-with driver package | Current |
| 0257Y520 | PCIe-network adapter-2288H V7-BCM957508-P2100G-network adapter-100Gb optical port-dual-port-QSFP28-half-height half-length-PCIE 4.0 x16-Vendor ID 14e4-Device ID 1750-2-Subvendor ID 14e4-Subdevice ID 2100 | Current |
| 0257Y551 | PCIe-network adapter-G5500 V7-BCM957608-P1400GDF00-network adapter-400 Gigabit-64bit-QSFP-DD-1 port-PCIE 5.0 x16-Vendor ID 14e4-Device ID 1760-1-Subvendor ID 14e4-Subdevice ID 9140 | Current |
| 0257Y770 | PCIe-GPU card-G8550 V8-G8550 V8-GPU01-NRP0600D PCIe GPU-PN:900-2G153-0030-000/84GB GDDR7 Memory/1398GB/s Memory Bandwidth/PCIE 5.0 x16-10DE-2BB9-1/600W-English documentation-Dual slot-Passive-GENERIC | Current |
| 0257Y771 | PCIe-GPU card-G8550 V8-G8550 V8-GPU02-PCIe-GPU card-G8550 V8-P800-GPU card-Kunlun core P800 PCIe Card-96GB/PCIE 4.0 x16-2057-3686-1,350W/DualSlot-Chinese documentation-No Cable-FHFL-GPU:Bridge Board = 4:1 | Current |
| 0257Y782 | PCIe-network adapter-G8550 V8-G8550 V8-DPU01-network adapter-200Gb/s-64bit-QSFP112-2 Ports-PCIE 5.0 X16-15b3-a2dc|c2d5-3-NVIDIA BlueField B3220 Crypto Disabled-Single-Slot-32GB DDR5-FHHL(incl. NCSI cable) | Current |
| 0257Y855 | PCIe-GPU card-G8550 V8-G8550_N300-Metax N300-48GB | Current |
| 3406Y008 | High Speed Transceiver,SFP28,850nm,25G,-8.4dBm,2.4dBm,-10.3dBm,LC,MM,0.1km,Original 34061254 split | Current Field replaceable |
| 3406Y006 | XFP|SFP+ Transceiver,SFP+,850nm,10Gb/s,-7.3dBm,-1dBm,-9.9dBm,LC,0.3km | Current Field replaceable |
| 3406Y011 | High Speed Transceiver,QSFP28,850nm,100G,-8.4dBm,2.4dBm,-10.3dBm,MPO,MM,0.1km,OM4 Original 34061089 split | Current Field replaceable |
| 3406Y007 | XFP|SFP+ Transceiver,SFP+,1310nm,10Gb/s,-8.2dBm,0.5dBm,-12.6dBm,LC,10km | Current Field replaceable |
| 0631Y040 | Network Card,25 GE,64bit,SFP28,2,PCIE 4.0 x8-15b3-101f-2,No Driver CD | Current Field replaceable |
| 3406Y033 | High Speed Transceiver,SFP28,850nm,25G,-8.4dBm,2.4dBm,-10.3dBm,LC,MM,0.1km,sont split | Current Field replaceable |
| 3406Y023 | High Speed Transceiver,QSFP56,850nm,200Gbps,-5.9dBm,4dBm,-4.4dBm,MPO12/UPC,MM,0.1km,8636 | Current Field replaceable |
| 3406Y012 | High Speed Transceiver,OSFP,850nm,400Gbps,-4.6dBm,4dBm,-4.4dBm,MPO-12/APC,MM,0.05km,OM4 Dedicated to IB NDR HCA | Current Engineer replace |
| 0632Y076 | GPU Card,Enflame S60 GPU,48GB Memory/672 GB/s Bandwidth/ PCIE 5.0 x16-1E36-C035-1,300W/DualSlot,Chinese doc,No Cable,FHFL | Current Field replaceable |
| 3406Y025 | High Speed Transceiver,OSFP,850nm,400Gbps,-4.6dBm,4dBm,-4.4dBm,MPO-12/APC,MM,0.05km,OM4 Dedicated to IB NDR HCA | Current Field replaceable |
| 0632Y106 | GPU Card,NVIDIA RTX 6000D PCIe GPU,PN:900-2G153-0030-000 / 84GB GDDR7 Memory / 1398GB/s Memory Bandwidth /PCIE 5.0 x16-10DE-2BB9-1 /600W,English doc,Dual slot,Passive,GENERIC | Current Field replaceable |
| 0302YAEC | Manufactured Board,G8550 V8,BC16RSWE,144 PCIe Switching Board - MESH Topology,1*1 | Current Field replaceable |
| 0302YAND | Manufactured Board,G8550 V8,BC16RSWEB,144 PCIe Switching Board - Double Up RingTopology,1*1 | Current Field replaceable |
| P/N | Description / Specification | Status |
|---|---|---|
| 0302Y238 | manufactured board-JDM-Public Module-BC55ETHA-XC385 OCP3.0 Ethernet adapter-25GE(CX6-Lx)-dual-port-SFP28(optical module not included)-PCIE 4.0 X8-Vendor ID 15b3-Device ID 101f-2-Subvendor ID 1f24-Subdevice ID 2011-1*4 | Current |
| P/N | Description / Specification | Status |
|---|---|---|
| 02313ADY | function module-TS200-2280-BC11TPMC02-TPM2.0 card(SPI)-China dedicated | Current |
| 02313APL | function module-TS200-2280-BC11TPMA02-TPM2.0 card(SPI)-international dedicated | Current |
| 03028HYW | Manufactured Board,TaiShan 200 (Model 2280),BC11TPMD,TPM2.0 Card(SPI), China Dedicated,5*4 | Current Engineer replace |
| 03024QEH | Manufactured Board,2288H V5,BC11TPMA,TPM2.0 Card(SPI), Overseas Dedicated,5*4 | Current Engineer replace |
| P/N | Description / Specification | Status |
|---|---|---|
| 0302Y170 | manufactured board-G8600 V7-BC15PNTA-NVME backplane(2*NVME)-2*2 | NONE |
| 0302Y860 | manufactured board-2288 V8-BC16NHBC-8*2.5 inch SAS/SATA/NVMe 3Cage drive backplane-1*2 | NONE |
| P/N | Description / Specification | Status |
|---|---|---|
| 0213Y069 | primary power supply--5degC-55degC-90V-264V-12V/264A(model DLK3201BM12C30,interface ) | Current |
| 0213Y103 | primary power supply--5degC-55degC-90V-264V-12V/264A(model CRPSAT3200TLW,interface IEC 320-C22) | Current |
| P/N | Description / Specification | Status |
|---|---|---|
| 0255Y698 | SSD module-Servers-M.2 SSD-SATA 6Gb/s-480GB-80.0mm * 22.0mm * 3.58 mm(non-hot-swappable)-ER3 series | Current |
| 0255YCUL | SSD module-Servers-M.2 SSD-NVMe PCIe-960GB-80.0mm * 22.0mm * 3.58 mm(non-hot-swappable)-PJ1 series | Current |
| 90010339 | Liquid Manufactory Auxiliaries,Thermal Grease,X-23-7868-2D,Thermal Conductivity 3.6W/mK / 6.0W/mK,2g,Gap filling thermal conductive for customer use,1ml | Current Engineer replace |
| 03025VYY | Manufactured Board,TaiShan 2280 V2,BC82LCIA,Left Customer Interface,4*2 | Current Engineer replace |
| 0302YAEA | Manufactured Board,BC16MBSBC,BC16MBSBC,1*1 | Current Field replaceable |
| 0302Y725 | Manufactured Board,2158H V8,BC15RCIAB,AMD Server 2U1P Right Customer Interface Board,5*2 | Current Engineer replace |
| 0302YAEE | Manufactured Board,BC16PTMA,RETIMER Adapter Board - 4*X16,1*2 | Current Field replaceable |
| 0302YAEG | Manufactured Board,BC16PTMAB,RETIMER Adapter Board - 8*X16,1*2 | Current Field replaceable |
| 0302YAEK | Manufactured Board,BC16CNTI,GPU power adapter board,1*5 | Current Field replaceable |
| 0231YGHF | Function Module,G8550 V8,G8550 V8-10UCHS03,AMD 10U Ring Dual Uplink/Dual285 Server Chassis(For Overseas Use) | Current Engineer replace |
| 0231YGGC | Function Module,G8550 V8,G8550 V8-10UCHS02,AMD 10U Full MESH / Ring Single Uplink Server Chassis | Current Engineer replace |
| 0231YGGB | Function Module,G8550 V8,G8550 V8-10UCHS01,AMD 10U Ring Dual Uplink/Dual285 Server Chassis | Current Engineer replace |
| 0231YGHG | Function Module,G8550 V8,G8550 V8-10UCHS04,AMD 10U Full MESH / Ring Single Uplink Server Chassis(For Overseas Use) | Current Engineer replace |
| 0258Y789 | IO Extended Module-PCIE,G8550 V8,G8550 V8-PRU13,slot41 NVMe M.2 Adapter Board Module(Includes High_Speed Cables, Low_Speed Cables,Installation Bracket) | Current Engineer replace |
| 0258Y773 | IO Extended Module-PCIE,G8550 V8,G8550 V8-PRU03,BF3 Riser with LSW Module | Current Engineer replace |
| 0258Y777 | IO Extended Module-PCIE,G8550 V8,G8550 V8-PRU05,slot41-42 2*2.5_NVMe_Module | Current Engineer replace |
| 0258Y784 | IO Extended Module-PCIE,G8550 V8,G8550 V8-PRU11,Air Duct Installation SATA M.2 Adapter Board Module(Includes High_Speed Cables, Low_Speed Cables) | Current Engineer replace |
| 0258Y783 | IO Extended Module-PCIE,G8550 V8,G8550 V8-PRU10,slot43 NVMe M.2 Adapter Board Module(Includes High_Speed Cables, Low_Speed Cables,Installation Bracket) | Current Engineer replace |
| 0258Y778 | IO Extended Module-PCIE,G8550 V8,G8550 V8-PRU08,slot43 1*CEM Module | Current Engineer replace |
| 0258Y765 | IO Extended Module-PCIE,G8550 V8,G8550 V8-PRU01,GPU Riser Module | Current Engineer replace |
| 0258Y776 | IO Extended Module-PCIE,G8550 V8,G8550 V8-PRU07,slot41-42 1*raid Module | Current Engineer replace |
| 0258Y775 | IO Extended Module-PCIE,G8550 V8,G8550 V8-PRU04,slot46 1*CEM Module(With Mounting Bracket Assembly) | Current Engineer replace |
| 0258Y772 | IO Extended Module-PCIE,G8550 V8,G8550 V8-PRU02,BF3 Riser Module | Current Engineer replace |
| 0258Y788 | IO Extended Module-PCIE,G8550 V8,G8550 V8-PRU12,slot41 SATA M.2 Adapter Board Module(Includes High_Speed Cables, Low_Speed Cables,Installation Bracket) | Current Engineer replace |
| P/N | Description / Specification | Status |
|---|---|---|
| 0405Y011 | High Speed Cable,25G SFP28 Passive High Speed Cable,3m,SFP28,CC2P0.254B(S),SFP28 | Current Engineer replace |
| 0405Y009 | High Speed Cable,10G Passive SFP+ Cable,5m,(SFP+20M),(CC2P0.4B),(SFP+20M),LSFRZH For Indoor,ETH 10GbE,Y | Current Engineer replace |
| 0405Y008 | High Speed Cable,10G Passive SFP+ Cable,1m,(SFP+20M),(CC2P0.254B),(SFP+20M),LSFRZH For Indoor,ETH 10GbE,LSZH | Current Engineer replace |
| 0405Y007 | High Speed Cable,10G SFP+ High Speed Cable,3m,SFP+20M,CC2P0.254B(S),SFP+20M,LSFRZH For Indoor,ETH 10GbE,LSZH | Current Engineer replace |
| 0415Y642 | Power Cable,250V-16A 3m,2.5mm^2(3C),black,C21,2.5mm^2(3C),C20 | Current Engineer replace |
| 0415Y154 | Power Cable,0.32m,black,80A STR easy connector,20*18UL2651B,80A R/A easy connector,Parallel Cable | Current Engineer replace |
| 0408Y231 | Monitor&Alarm Cable,signal cable,0.45&0.58M,H2X15(1.25),18*UL1685 28AWG+4*28UL1685(S),2*(H2X6(2.0)) | Current Engineer replace |
| 0408Y230 | Monitor&Alarm Cable,signal cable,0.5m,H2X10(1.0),16*28UL1685+2*28UL1685(S),H2X10(1.0) | Current Engineer replace |
| 1427Y004 | BTB Connector module,74PIN,MCIO 8X Vertical,350mm,0.16mm,10mm,32000MB/s,1.57mm,Wire mounting,Y | Current Engineer replace |
| 0408Y235 | Monitor&Alarm Cable,signal cable,1.05m,H2X25(1.25),20*28UL1685B+5*28UL1685B(S),H2X25(1.0) | Current Engineer replace |
| 0408Y234 | Monitor&Alarm Cable,Signal Cable,1.050m,H2X10(2.0),14*28UL1685B/4*28UL1685B(S),H2X10(2.0),6/8/13/15Pin shield | Current Engineer replace |
| 0408Y233 | Monitor&Alarm Cable,signal cable,0.55&0.45M,H2X20(1.25),34*UL1685 28AWG,H2X8(2.0))+H2X20(1.25) | Current Engineer replace |
| 0408Y229 | Monitor&Alarm Cable,signal cable,450mm,H2X20(1.25),28*28UL1685+6*28UL1685(S),H2X20(1.25) | Current Engineer replace |
| 0415Y643 | Power Cable,3m,2.5mm^2(3C),black,PI RM,2.5mm^2(3C),C21 | Current Engineer replace |
| 0415Y676 | Power Cable,0.35m,radsok STR,2*10mm^2(Black)+2*10mm^2(Red),BK150 | Current Engineer replace |
| P/N | Description / Specification | Status |
|---|---|---|
| 2116Y155 | Special heat sink,2116Y155_DRAEN.ASM,AMD extended heat sink (2U, 2U body),G8650 V3 | Current Engineer replace |
| 0231YGBV | Function Module,G8550 V8,G8550 V8-FANM01,200W 1*8080++Fan module | Current Field replaceable |
| 0231YGRN | Function Module,G8550 V8,G8550 V8-FANM02(with PCBA),200W 1*8080++Fan module(with PCBA) | Current Field replaceable |
| 0302YAEH | Manufactured Board,BC16FDCG,20*8080 fan board,1*1 | Current Field replaceable |
Operating System Compatibility
| Operating System | Version / Kernel | Release |
|---|---|---|
| FusionOS 23 | 5.10.0-136.23.0.99.u37.fos23.x86_64 | FusionOS 23 |
| RHEL 8.10 | 4.18.0-553.el8_10.x86_64 | Red Hat Enterprise Linux 8 Update 10 Server for Intel EM64T |
| RHEL 9.4 | 5.14.0-427.13.1.el9_4.x86_64 | Red Hat Enterprise Linux 9 Update 4 Server for Intel EM64T |
| Rocky Linux 8.10 | 4.18.0-553.el8_10.x86_64 | Rocky Linux 8 Update 10 Server for Intel EM64T |
| Rocky Linux 9.4 | 5.14.0-427.13.1.el9_4.x86_64 | Rocky Linux 9 Update 4 Server for Intel EM64T |
| SLES 15 SP6 | 6.4.0-150600.21-default | SUSE Linux Enterprise Server 15 Service Pack 6 for AMD64 & Intel64 |
| Ubuntu 24.04 LTS | 6.8.0-31-generic | Ubuntu 24.04 LTS Server Edition for Intel EM64T |
| VMware ESXi 8.0 U3 | build-24022510 | VMware ESXi 8.0 Update 3 for Intel EM64T |
| VMware ESXi 9.0 | build-24755229 | VMware ESXi 9.0 for Intel EM64T |
| VMware ESXi 9.1 | build-25370933 | VMware ESXi 9.1 for Intel EM64T |
| Windows Server 2022 | Build 20348 | Microsoft Windows Server 2022 x64 |
| Windows Server 2025 | Build 26100 | Microsoft Windows Server 2025 x64 |
| openEuler 24.03 LTS | 6.6.0-28.0.0.34.oe2403.x86_64 | openEuler 24.03 LTS (powered by openEuler) |
Configuring, expanding or replacing this server? Send us your part list or BOM for a fast quotation.
Request a QuoteSelecting components for the G8550 V8
These points from the matrix matter when configuring or expanding a unit:
- Memory: DDR5 RDIMMs from 64GB to 128GB at up to 6400 MT/s. Give us your capacity target and we will confirm the supported DIMM population and channel rules.
- RAID levels follow the controller. The validated controllers support RAID 1. Cacheless entry cards suit boot and mirroring; cached cards with a supercapacitor enable parity RAID for data arrays; JBOD/IT cards provide passthrough to software RAID.
- Storage mix. Validated options include SAS/SATA drives up to 4 TB and PCIe NVMe SSDs up to 8 TB. Backplane and tray variants are listed separately under Drive Backplanes.
- Networking from 25GbE to 200GbE. OCP 3.0 and PCIe adapters are validated for the listed speeds; some SKUs include optical modules and others do not, so check the part description.
Reference workload profiles
These profiles show how validated components combine; each is configured and quoted to order.
- AI training: maximum supported GPUs with NVLink/fabric, high-core CPUs, large memory, titanium PSU.
- AI inference / serving: right-sized GPU count, NVMe for models, high-throughput networking.
- Scientific / HPC compute: GPUs plus high-frequency CPUs, ECC memory, InfiniBand.
- GPU virtualization / VDI: virtualised GPUs, many users, fast boot and network storage.
The G8550 V8 in the FusionServer range
The numbered FusionServer generations make it straightforward to choose between current and supported hardware. The G8550 V8 is a V8 platform: Intel Xeon 6 (Granite Rapids / Sierra Forest), DDR5, PCIe 5.0.
Earlier supported generations remain useful:
- V7: 4th/5th Generation Intel Xeon Scalable, DDR5, PCIe 4.0/5.0 — supported, cost-effective for standardised or budget projects.
- V6: 3rd Generation Intel Xeon Scalable, DDR4, PCIe 4.0 — supported, cost-effective for standardised or budget projects.
- V5: 1st/2nd Generation Intel Xeon Scalable, DDR4, PCIe 3.0 — supported, cost-effective for standardised or budget projects.
We supply new systems with manufacturer warranty and can source validated parts for earlier generations when a budget, software-licensing or support window calls for them. Ask us which generation fits.
G8550 V8 — compatibility FAQ
What memory can I install?
Validated DDR5 RDIMMs range from 64GB to 128GB at up to 6400 MT/s. Tell us your capacity target and we will confirm the supported DIMM population.
Which RAID levels are supported?
Validated controllers support RAID 1. Choose a cached card with a supercapacitor for parity RAID (5/6/50/60), an entry card for 0/1/10, or an IT/JBOD card for software RAID passthrough.
What drives are validated?
The matrix lists SAS/SATA drives up to 4 TB and NVMe SSDs up to 8 TB. See the Hard Drives and NVMe tabs for the full list, form factors and current status.
What network speeds are supported?
Validated OCP and PCIe adapters cover 25GbE, 200GbE. Note whether a SKU includes optical modules; we can supply matched optics if required.
Which operating systems are certified?
The OS matrix lists 13 certified builds, including Red Hat Enterprise Linux, Rocky Linux, SUSE Linux Enterprise Server, Ubuntu, VMware ESXi, Windows Server, each with its exact kernel or build string. Additional builds can often be confirmed on request.
What do the lifecycle statuses mean?
Current/GA parts are in production; PILOT and DEVELOP parts are under limited rollout or qualification; EOM parts are out of marketing but supported as spares. Prefer Current parts for new builds.
Can you supply the server or just parts?
Both. We configure complete systems and supply every validated component listed here with warranty. Send a part list or BOM for a fast quotation.
serverbastion.com

WeChat
Scan the QR Code with wechat