Call: +86 18001060290    E-mail: info@sell-server.com

Huawei Storage Memory, CPU & Quorum Server Parts (37)

Huawei Storage Memory, CPU & Quorum Server Parts (37)

Huawei storage memory, quorum servers and support modules (37 P/Ns)

37 controller memory modules, quorum servers, service processors and internal switches for OceanStor and Dorado. Supporting infrastructure, each with its own matching rule.

Part numbers
37
Component types
6
Memory capacities
16 GB, 32 GB, 64 GB
Matching rule
Per component type

This is the group nobody looks at until something stops

37 part numbers, and they have almost nothing in common: controller memory, quorum servers, service processors, internal PCIe switches, a switch, a modem. What they share is that they are all supporting infrastructure — none of them carries user data, and all of them can stop a system working.

ComponentP/Ns
Quorum server9
Service processor8
Memory module (DIMM)7
Other5
PCIe switch3
Ethernet switch2
Modem / remote access2
KVM1

Controller memory is matched, not upgraded

7 rows are memory modules. In a storage controller these are not user-upgradable in the way server memory is: the controller model was qualified with a specific capacity per slot and a specific population, and the cache size in the datasheet follows from that. The capacities present here are 16 GB 2, 32 GB 3, 64 GB 2.

Module capacityP/Ns
32 GB3
16 GB2
64 GB2
  • Match the controller model, not the slot count. Two controllers with the same slot count can specify different module capacities.
  • Rank and organisation matter: the description states the rank and the device width.
  • A larger module does not always give more cache — the controller may not address it.
  • Mixed population across a controller pair is a supported-state question. Ask before you mix.

DDR4 versus DDR5 is visible in the description

The descriptions here name the generation and the transfer rate — for example DDR4 RDIMM at 2933 MT/s or 3200 MT/s, and later parts at 5600 MT/s. The rate and the voltage are the two figures that tell you which controller generation the module belongs to. The rank split in this list is 1R 3, 2R 4.

  • Higher transfer rate does not mean compatible: the controller memory bus sets the ceiling.
  • RDIMM means registered, with a buffer between the DRAM and the bus. Unbuffered modules are not substitutes.
  • ECC is present on every module here; it is a controller requirement, not an option.

The quorum server is the smallest part that stops the cluster

9 rows are quorum servers. In a two-site stretched cluster the quorum server is the third vote: without it the two sites cannot decide which one should keep serving, and the cluster stops. It is a 1U box with modest specification and it is the part most often left out of a disaster-recovery spare list, because it does not look like storage.

  • A quorum server is not a general-purpose server; the software image is part of the product.
  • Some deployments use a quorum disk instead. Confirm which your design uses before ordering.
  • Keep the quorum server on a site that is independent of both data sites.

Service processors and internal switches

8 rows are service processors and 3 are PCIe switches. A service processor is the management appliance for a storage system: it runs the management software, presents the web interface and collects logs. If it fails the data path keeps running and you lose management, alerting and support access. The PCIe switch is internal fabric between the controller and NVMe bays; it is invisible until it is not.

  • Service processors ship with an operating system image; the image version matters for management compatibility.
  • Some service processor variants differ only in power input (AC or 48 V DC).
  • A PCIe switch failure usually presents as missing NVMe bays, not as a controller fault.

Full part-number list, 37 P/Ns

P/NDescription (official)ModelsReplaces
02314MAXFunction Module,PANGEA,STL07M16G,Memory Module,DDR4 RDIMM,16GB,288pin,0.68ns,2933000KHz,1.2V,ECC,1Rank(2G*4bi…6—
02314PLTFunction Module,FusionStorage,STL06M32G,Memory Module,DDR4 RDIMM-32GB-288pin-0.625ns-3200000KHz-1.2-ECC,preme…8—
02314QDSFunction Module,PANGEA,STL06M64G,Memory Module,DDR4 RDIMM-64GB-288pin-0.625ns-3200000KHz-1.2V-ECC-2Rank(4G*4b…2—
02314VKBFunction Module,PANGEA,STL08M32G,Memory Module,DDR4 RDIMM-32GB-288 PIN-0.625ns-3200000KHz-1.2V-ECC-all produc…3—
02314VWBFunction Module,PANGEA,STL06M64G,Memory Module,DDR RDIMM Memory,64GB,5600000KHz,2Rank(4G*4bit),1.1V,ECC,preme…1—
02314VWCFunction Module,PANGEA,STL06M32G,Memory Module,DDR RDIMM Memory,32GB,5600000KHz,1Rank(4G*4bit),1.1V,ECC,preme…1—
02350MKFPANGEA,STLZ04NPEB,PCIe 3.0 Switch(AC\240HVDC,8GB Cache,16 Port,SWE1600P08)3—
02350RTBAssembling Components,CE6800,CE6855-HI-F-B0A,CE6855-48S6Q-HI Switch(48-Port 10G SFP+,6-Port 40GE QSFP+,2*AC P…14—
02350SRQAssembling Components,CE6800,CE6855-48S6Q-HI,CE6855-48S6Q-HI Switch(48-Port 10G SFP+,6-Port 40GE QSFP+,2*FAN…9—
02351MYLAssembling Components,STLZ01SVPD01,Service Processor (1U, AC\240HDVC,16GB Cache,Including Windows OS Software…402353KRJ (One-way; Complete)
02351MYMPANGEA,STLZ07NPEB,PCIe 3.0 Switch(AC\240HVDC,8GB Cache,16 Port,SWE1600P08),Just for High level market502351YLS (One-way; Complete)
02351RBNRH1288 V3,STLZ1HMAOC,Quorum Server(1U, AC\240HVDC,8GB Cache,Including OS)5—
02351TPXAssembling Components,STLZ01SVPD03,Service Processor (1U, AC\240HDVC,16GB Cache,Including Windows OS Software…402353KRJ (One-way; Complete)
02351YEXAssembling Components,STLZ01SVPD04,Service Processor (1U, 48VDC,16GB Cache,Including Windows OS Software and…102352DBC (One-way; Complete)
02351YFAAssembling Components,STLZ01SVPD05,Service Processor (1U, 48VDC,16GB Cache,Including Windows OS Software,H12H…402352DBC (One-way; Complete)
02351YLSAssembling Components,PANGEA,STLZ10NPEB,PCIe 3.0 Switch(AC\240HVDC,8GB Cache,16 Port,SWE1600P08),Spare parts5—
02352CQGAssembling Components,STLZ01SVPD09,Service Processor (1U, AC\240HDVC,16GB Cache,Including Windows OS Software…402353KRJ (One-way; Complete)
02352CQHAssembling Components,STLZ01SVPD08,Service Processor (1U, AC\240HDVC,16GB Cache,Including Windows OS Software…402353KRJ (Not stated; Not stated)
02352DBCAssembling Components,STLZ01SVPD06,Service Processor (1U, 48VDC,16GB Cache,Including Windows OS Software,H12H…4—
02352ESUAssembling Components,1288H V5,STLZ1HMA05,Quorum Server(1U, AC\240HVDC,16GB Cache,Including OS,H12H-05)4102352ESX (One-way; Complete)
02352ESXAssembling Components,1288H V5,STLZ1HMA06,Quorum Server(1U, AC\240HVDC,16GB Cache,Including OS,H12H-05),for S…27—
02353APJAssembling Components,TaiShan 200(Model 2280),STLZ05HMA,Quorum Server(2U, AC\240V HVDC,2*32GB Cache,Including…2102353CJS (One-way; Complete)
02353CJSAssembling Components,TaiShan 200(Model 2280),STLZ06HMA,Quorum Server(2U, AC\240HVDC,2*32GB Cache,Including O…21—
02353KRJAssembling Components,STLZ01SVPD10,Service Processor (1U, AC\240HDVC,16GB Cache,Including Windows OS Software…402352CQH (One-way; Complete)
02353NKGAssembling Components,TaiShan 200(Model 2280),STLZ05HMA01,Quorum Server(2U,India 2000W AC,2*32GB Cache,Includ…2102353NKH (One-way; Complete)
02353NKHAssembling Components,TaiShan 200(Model 2280),STLZ06HMA01,Quorum Server(2U,India 2000W AC,2*32GB Cache,Includ…21—
02354CTWAssembling Components,OceanStor 5310 V5,STLZ6SPCI170,5310 V5(2U,Dual Ctrl,SAS,AC\240V HVDC,256GB Cache,8*1Gb…1—
02354CTYAssembling Components,OceanStor 5300 V5 Kunpeng,STLZ6SPCI172,5300 V5(2U,Dual Ctrl,SAS,AC\240V HVDC,256GB Cach…1—
02354NBKAssembling Components,TaiShan 200(Model 2280),STLZ05HMA02,Quorum Server(2U, AC\240V HVDC,2*32GB Cache,Includi…6—
02355NWPAssembling Components,TaiShan 200(Model 2280),Quorum Server(2U, AC\240V HVDC,2*32GB Cache,Including OS,TaiSha…4—
06040189KVM,KVM,kinan,1U,17" LED, 8 KVM ports,1 USB Straight signal cables/With mounting Accessories,High-end Storage…4—
06200213Memory Module,DDR4 RDIMM,16GB,288pin,0.83ns,2400000KHz,1.2V,ECC,Server Dedicated,2Rank(1G*8bit)4—
41020682X86 series,FCLGA3647,1700MHz,1.6V/1.83V,64bit,85000mW,Skylake-SP Xeon Bronze 3104-6Core-IT Product Dedicated4—
50030084MODEM,Wireless GPRS,Radio Interface,External,100~240VAC To 12V DC Adapter,Plug 5.5×2.1mm,English/Chinese Docu…22—
50030088Modem-56Kbps,2 Wire Dedicated Wire/Data/Fax,External Type,DB25 to DB9 Cable,English/Chinese DOC,220VAC To 12V…22—
50100862Other Network Accessory,KMIP KeyAuthority ,AC 220V,KMIP standard,symmetric/asymmetric cripto key management,E…16—
50101199Other Network Accessory,KMIP ,AC 220V,KMIP standard,symmetric/asymmetric cripto key management,English doc,FI…20—

Descriptions are the official catalogue text, including capacity, rank, transfer rate and voltage for memory modules where Huawei publishes them.

Before you order from this group

  • For memory, match the controller model and the qualified capacity per slot.
  • For a quorum server, confirm whether your design uses a server or a disk.
  • For a service processor, confirm the management software version compatibility.
  • For a PCIe switch, confirm the enclosure generation — it is not a generic part.
  • Send us the system model; this group has the widest spread of matching rules on the site.

Frequently asked questions

Can I increase controller cache by fitting larger memory modules?

Not reliably. The controller is qualified with a specific capacity per slot; a larger module may not be addressed.

Is server memory a substitute for controller memory?

No. Registered ECC modules with the specified rank and organisation are required, and the controller memory bus sets the rate ceiling.

What happens if the quorum server fails?

In a stretched cluster the two sites lose their tie-breaker and the cluster stops serving. It is a small part with a large consequence.

Does a failed service processor stop I/O?

Usually not. You lose management, alerting and support access, and the data path keeps running.

Why do some service processors differ only in power input?

Because the same appliance is offered for AC cabinets and for 48 V DC sites. The part number differs; the function does not.

Request a quotation

Send the part number, the storage model or the serial number. We confirm the fit against the official spare-part catalogue, then quote and ship from China.

Get a quotationAll Huawei storage parts

← Back to Huawei storage spare parts

Leave a message