Huawei storage power supplies and BBUs (86 P/Ns)
86 power supplies, DC modules and battery units for OceanStor and Dorado. Input type, output rating and airflow direction all have to match.
- Part numbers
- 86
- AC / DC
- 46 AC, 25 DC
- Rating range
- 350 W to 3000 W
- Battery parts
- 17
AC and DC are two product lines, not two options
Of the 86 rows, 46 are AC-input supplies and 25 are DC-input. The split is not a preference at order time: the input range differs by an order of magnitude (90-264 V AC against a -38 to -75 V DC rail), the connectors differ, and the systems that take one generally do not take the other without a different power shelf.
- AC supplies take a wide-range mains input and are the default in enterprise cabinets.
- DC supplies take a telecom-style negative 48 V rail and are common in carrier and central-office sites.
- A DC-powered system needs DC distribution, breakers and often a different PDU — plan the whole chain.
- Do not convert a system from AC to DC by changing supplies alone.
Power rating is the sizing number
The wattage in the description is the output rating of the module, and it is the number that decides how many modules a shelf needs and whether the configuration survives one module failing. The ratings present in this list are 350 W 1, 600 W 3, 750 W 1, 800 W 2, 900 W 12, 960 W 2, 1200 W 9, 1800 W 2, 1950 W 1, 2000 W 23, 2200 W 3, 3000 W 1.
| Output rating | P/Ns |
|---|---|
| 2000 W | 23 |
| 900 W | 12 |
| 1200 W | 9 |
| 600 W | 3 |
| 2200 W | 3 |
| 800 W | 2 |
| 960 W | 2 |
| 1800 W | 2 |
| 350 W | 1 |
| 750 W | 1 |
| 1950 W | 1 |
| 3000 W | 1 |
Two supplies of the same wattage from different generations are not automatically interchangeable. The form factor, the connector and the airflow direction all have to match as well, and the shelf firmware may report an unknown module if the generation is too far apart.
Airflow direction is a hard requirement
Supplies in this list are marked either front-to-back or back-to-front, and the marking is not cosmetic: it describes which way the fan pushes air through the module. In a cabinet where all equipment moves air the same way, fitting one supply with the opposite airflow creates a hot spot that the thermal design never accounted for. In the rows here the split is Front to back 1, Back to front 1.
- Match airflow to the rest of the cabinet, not to the supply you happened to find.
- Front-to-back and back-to-front modules usually carry the same rating and look identical.
- The airflow direction is in the description. Read it before you order two.
Input range and derating
The description carries the operating temperature range and the input voltage window, for example -5 to 55 degrees C at 90-264 V AC. Those two figures define where the module can be deployed, and they are the reason two supplies of the same wattage are not always the same product: a module rated to 50 degrees C delivers less at the top of its range than one rated to 55.
- Check the temperature range against the cabinet’s actual inlet temperature, not the room.
- Output derates with inlet temperature; the nameplate wattage is not available at 55 degrees C.
- Multi-output modules state a combined capacity for the shared rails — read that figure, not the sum.
Battery and BBU parts are a separate maintenance item
17 rows are battery or BBU related. These are consumables with a service life, not fit-and-forget components: a cache-protection battery that has aged out will put the controller into write-through and cut performance long before it reports a hard failure.
- Replace on the calendar, not on the alarm.
- A BBU that has been held in storage for years has been ageing; check the manufacture date.
- Match the battery to the controller generation — the connector and the charge profile differ.
Full part-number list, 86 P/Ns
| P/N | Description (official) | Models | Replaces |
|---|---|---|---|
| 02130985 | AC-DC Power,-5degC,55degC,90V,264V,12.3V/96A | 8 | — |
| 02131006 | AC-DC Power,-5degC,55degC,90V,264V,12V/50A;5V/36A,Overall Combined Capacity of the 12V and 5V Power Supply is… | 35 | 02311DEP (Two-way; Complete) |
| 02131255 | AC-DC Power,5degC,55degC,90V,264V,12V/45A | 41 | — |
| 02131348 | AC-DC Power,5degC,50degC,90V,264V,12.3V/96A | 9 | — |
| 02131761 | AC-DC Power,5degC,55degC,90V,264V,12V/66.7A,5V/36A,Overall Combined Capacity of the 12V and 5V Power Supply i… | 35 | 02311DEP (Two-way; Complete) |
| 02220738 | Adapter,-5degC,40degC,90V,264V,12V/5A,2PIN In/4PIN Out | 4 | — |
| 02270131 | DC-DC Module,600W,-5degC,55degC,-38.4V,-75V,12V/50A;5V/36A,10000uF,Overall Combined Capacity of the 12V and 5… | 25 | — |
| 02270132 | DC-DC Module,960W,-5degC,55degC,-38.4V,-75V,12V/80A;5V/36A;12Vsb/2A,10000uF,Overall Combined Capacity of the… | 3 | — |
| 02310PMJ | Function Module,AC PSU,PAC-600WA-F,600W AC Power Module(Front to Back,Power panel side intake) | 14 | — |
| 02310PQN | Function Module,DC PSU,PDC-350WA-B,350W DC Power Module(Back to Front,Power panel side exhaust) | 9 | — |
| 02310QWX | Function Module,EPW750-12A,EN3MCACC,750W platinum AC power supply unit | 5 | — |
| 02310TBR | Function Module,HSP960-D1205A,EN3MCACB,960W platinum AC power supply unit | 7 | — |
| 02310UWW | Function Module,HSP1800-S12A,HSP1800-S12A,1800W platinum AC power supply unit | 1 | — |
| 02310UWW-001 | Function Module,HSP1950-S12A,HSP1950-S12A,1950W platinum AC power supply unit | 12 | — |
| 02311DEP | Function Module,PAC800D1205-CE,PAC800D1205-CE,800W platinum AC power supply unit | 21 | 02131761 (One-way; Complete) |
| 02311QLP | Function Module,DC-DC,HSP1800-S12D,storage 1800W DC power supply 48V | 6 | — |
| 02312BLL | Function Module,PDC1200S12-CE,PDC1200S12-CE,PDC1200S12-CE DC power supply unit | 4 | — |
| 02312HEG | Function Module,AC-DC POWER SUPPLY,5degC,50degC,90-264Vac,12V/100A,Server Platinum 1200W power supply,86*196*… | 6 | — |
| 02312HGY | Function Module,PAC2000S12-BG,PAC2000S12-BG,Function Module,PAC2000S12-BG,PAC2000S12-BG,Server Platinum 2000W… | 20 | — |
| 02312QWS | Function Module,DC-DC,PDC1200S12-CF,Server 1200W DC power supply 48V | 1 | — |
| 02312QXD | Function Module,PAC2000S12-BG,PAC2000S12-BG,Function Module,PAC2000S12-BG,PAC2000S12-BG,Server Platinum 2000W… | 20 | — |
| 02312RHU | Function Module,AC-DC,PHD2200S12-B1,Platinum 2200W HVDC power supply 336V | 7 | — |
| 02312SRL | Function Module,AC-DC,PAC3000S12-T1,Server Titanium 3000W AC power supply | 4 | — |
| 02312SXL | Function Module,PDC2000S12-B1,Server 2000W DC power supply 48V | 2 | — |
| 02312XWK | Function Module,AC-DC PAC900S12-B2,Server Platinum 900W Version 2.0 AC power supply | 21 | — |
| 02312YKR | Function Module,AC-DC PAC2000S12-B1,Server Platinum 2000W Version 2.0 AC power supply | 16 | 02356TYA (One-way; Conditional) |
| 02313NFU | Function Module,AC-DC,PAC900S12-T1,Server Titanium 900W Version 2.0 AC power supply | 4 | — |
| 02313XMV | Function Module,AC-DC,PAC2000S12-B1,Server Platinum 2000W Version 2.0 AC power supply-India Item only | 1 | — |
| 02314GVY | Function Module,AC-DC,PAC2000S12-T2,Titanium 2000W AC power supply | 9 | — |
| 02314PDL | Function Module,AC-DC,PAC900S12-B3,Server 900W Version 3.0 AC power supply | 1 | — |
| 02314VNQ | Function Module,AC-DC,PAC2000S12-T3,High-end storage power supply Titanium 2000W Si AC power supply,HQ | 6 | 02357AGL (One-way; Conditional) |
| 02350FHW | Assembling Components,PANGEA,STLZ03PWRB,Backup Battery Unit | 7 | — |
| 02352TYU | Assembling Components,PANGEA V6,STLE02PWRB,Integrated 1200W DC Power Module | 3 | — |
| 02352TYV | Assembling Components,PANGEA V6,STLE03PWRB,Integrated 2000W AC Power Module | 27 | — |
| 02353MRU | Assembling Components,PANGEA V6,STLE07PWRB,Integrated 2000W AC Power Module,for India | 19 | — |
| 02353MRV | Assembling Components,PANGEA V6,STLE08PWRB,Integrated 1200W DC Power Module,for India | 3 | — |
| 02353PMV | Assembling Components,PANGEA V6,STLE09PWRB,Integrated 900W AC Power Module,V99 | 1 | — |
| 02353PQN | Assembling Components,PANGEA V6,STLE10PWRB,Integrated 1200W DC Power Module,V99 | 2 | 02352TYU (Two-way; Complete) |
| 02353UJQ | Assembling Components,PANGEA V6,STLE13PWRB,Integrated 2000W AC Power Module,BCM+ | 4 | — |
| 02353UJR | Assembling Components,PANGEA V6,STLE14PWRB,Integrated 1200W DC Power Module,BCM+ | 15 | — |
| 02353UJS | Assembling Components,PANGEA V6,STLE15PWRB,Integrated 900W AC Power Module,BCM+ | 31 | 02356SXQ (One-way; Complete) |
| 02353VAE | Assembling Components,PANGEA V6,STLE16PWRB,Integrated 2200W HVDC Power Module,BCM+ | 13 | — |
| 02354ADL | Assembling Components,PANGEA V6,STL6CPWRE02,Integrated 900W AC Power Module,BCM | 1 | — |
| 02354ADM | Assembling Components,PANGEA V6,STL6CPWRE03,Integrated 2000W AC Power Module,BCM+ | 5 | 02356SXV (One-way; Complete) |
| 02354BQW | Assembling Components,PANGEA V6,STL6CPWRE04,Integrated 1200W DC Power Module,BCM+ | 3 | — |
| 02354BQX | Assembling Components,PANGEA V6,STL6CPWRE05,Integrated 2200W HVDC Power Module,BCM+ | 1 | — |
| 02354BTB | Assembling Components,PANGEA V6,STLE17PWRB,Integrated 1200W DC Power Module,for India | 7 | — |
| 02354BTC | Assembling Components,PANGEA V6,STLE18PWRB,Integrated 2000W AC Power Module,for India | 19 | — |
| 02354CCS | Assembling Components,PANGEA V6,STL6CPWRE06,Integrated 1200W DC Power Module,for India | 3 | — |
| 02354CCT | Assembling Components,PANGEA V6,STL6CPWRE07,Integrated 2000W AC Power Module,for India | 3 | — |
| 02354JQD | Assembling Components,PANGEA V6,STLE19PWRB,Integrated 900W AC Power Module,BCM+ | 13 | 02356SXQ (One-way; Complete) |
| 02355AHQ | Assembling Components,PANGEA V6,STLE21PWRB,Integrated 2000W DC Power Module,Not Spare Part | 2 | 02355AJH (One-way; Complete) |
| 02355AJH | Assembling Components,PANGEA V6,STLE23PWRB,Integrated 2000W DC Power Module,Spare Part | 2 | — |
| 02355HQK | Assembling Components,PANGEA V6,STLE22PWRB,Integrated 2000W AC Power Module | 5 | — |
| 02355HQL | Assembling Components,PANGEA V6,STLE24PWRB,Integrated 900W AC Power Module,BCM+ | 20 | 02356SXP (One-way; Complete) |
| 02355HQM | Assembling Components,PANGEA V6,STL6CPWRE10,Integrated 2000W AC Power Module,BCM+ | 3 | 02356VTY (One-way; Complete) |
| 02356SXP | Assembling Components,PANGEA V6,STLE24PWRB1,Integrated 900W AC Power Module,BCM+ | 12 | — |
| 02356SXQ | Assembling Components,PANGEA V6,STLE19PWRB1,Integrated 900W AC Power Module,BCM+ | 13 | — |
| 02356SXV | Assembling Components,PANGEA V6,STL6CPWRE12,Integrated 2000W AC Power Module,BCM+ | 3 | — |
| 02356TYA | Assembling Components,PANGEA V6,STLE13PWRB3,Integrated 2000 W AC power module | 10 | — |
| 02356VTY | Assembling Components,PANGEA V6,STL6CPWRE11,Integrated 2000W AC Power Module,Titanium 2.0 | 3 | — |
| 02357AGL | Assembling Components,PANGEA V6,PAC2000S12-T3,Integrated Titanium 2000W Si AC Power Module | 10 | — |
| 02357EGB | Assembling Components,PANGEA V6,STLE19PWRB3,Integrated 900W AC Power Module,BCM+ | 1 | — |
| 02357EGC | Assembling Components,PANGEA V6,STLE19PWRB4,Integrated 900W Titanium AC Power Module,BCM+ | 1 | — |
| 02357EGD | Assembling Components,PANGEA V6,STLE19PWRB5,Integrated 2000 W Platinum AC Power Module,BCM+ | 1 | — |
| 02357EGE | Assembling Components,PANGEA V6,STLE19PWRB6,Integrated 2000W Titanium AC Power Module,BCM+ | 1 | — |
| 02359137 | Assembling Components,PANGEA,STLZ03PWRA,Backup Battery Unit | 5 | — |
| 0302090206 | Manufactured Board-JDM,PANGEA,STL6PWRZ,C90 High Density Disk Enclosure Power Transfer Board,2*4,JDM | 4 | — |
| 03031MPJ | Finished Board,PANGEA,STL2BATTA01,Battery Backup Unit,V2R1C00 | 1 | — |
| 03031SNT | Finished Board,PANGEA,STL2APCAA,PCIe 3.0 Switch Power Module | 5 | — |
| 03032PYM | PANGEA,STL2BATTA03,Battery Backup Unit,PANGEA V2R5C00 | 7 | — |
| 03033CDX | Finished Board,PANGEA,STL6BATTD03,Battery Backup Unit,PANGEA V6R1C00 | 6 | — |
| 03033CTT | Finished Board,PANGEA,STL6BATTC01,Battery Backup Unit,for High-end only | 6 | — |
| 03033EMR | Finished Board,PAGNEA,STL6PWRA01,Battery Backup Unit | 6 | — |
| 03033GAK | Finished Board,PANGEA,STL6BATTC05,Battery Backup Unit | 2 | 03033CTT (One-way; Complete) |
| 03033MSB | Finished Board,PANGEA,STL6BATTE03,Battery Backup Unit,PANGEA V600R003C00 | 9 | 03036AQJ (One-way; Complete) |
| 03033MSV | Finished Board,PANGEA,STL6BATTF05,Battery Backup Unit,BCM ,for high end only | 12 | — |
| 03033QNX | Finished Board,PANGEA,STL6BATTF03,Battery Backup Unit,BCM+ | 6 | 03033MSV (One-way; Complete) |
| 03033RST | Finished Board,PAGNEA,STLZ6PWRA03,Battery Backup Unit | 8 | — |
| 03034HHW | Finished Board,PAGNEA,STLZ6PWRA03,Battery Backup Unit | 14 | 03034LHR (One-way; Complete) |
| 03034LHR | Finished Board,PANGEA,STLZ6PWRA04,Battery Backup Unit,Spare parts | 14 | — |
| 03036AQJ | Finished Board,PANGEA,Battery Backup Unit,PANGEA V600R011C00 | 6 | — |
| 04053152 | Power cord,Britain AC Power 250V13A,3.0m,PGAM,H05VV-F-1.5mm^2(3C),C19SF,250V,13A,Black-Only for Saudi Arabia… | 1 | — |
| 04053236 | Power cord,Europe/KOR AC 250V16A,3.0m,PFAM,H05VVF-1.5^2(3C),C19SF,250V,16A,Black | 1 | — |
| 24010019 | Original Battery,Li&Mn Battery,3V,0.225Ah,Round,20mm*3.2mm | 5 | — |
| 24010067 | Original Battery,Li-(CFx)n battery,3V,0.19Ah,Round,D20*3.2mm | 3 | — |
Input range, output rating and airflow direction are taken from the official description where Huawei publishes them.
Before you order a power supply
- Confirm AC or DC input — this decides the whole power chain, not just the module.
- Confirm the output rating the shelf needs and whether it must survive one module failing.
- Confirm the airflow direction matches the rest of the cabinet.
- Confirm the form factor and connector against the shelf generation.
- For batteries, confirm the manufacture date, not only the part number.
Frequently asked questions
Can I replace an AC supply with a DC one?
No. The input rail, connector and the whole distribution chain differ. It is a system change, not a module swap.
Does a higher-wattage supply work in place of a lower one?
Sometimes, if form factor, connector and airflow match and the shelf firmware recognises it. Confirm before ordering.
Why does airflow direction matter?
Because a module pushing air the wrong way creates a hot spot the cabinet thermal design did not account for. It is a hard requirement, not a preference.
Is the nameplate wattage available at maximum temperature?
No. Output derates with inlet temperature. Size against the derated figure at your cabinet’s inlet temperature.
When should a BBU be replaced?
On the calendar, not on the alarm. An aged battery silently forces write-through before it fails.
Request a quotation
Send the part number, the storage model or the serial number. We confirm the fit against the official spare-part catalogue, then quote and ship from China.
serverbastion.com

WeChat