By the ServerBastion solutions team — Beijing Xinchuan Technology Co., Ltd. · Specs checked against Dell official spec sheets, October 2026.
For a PowerEdge deployment in late 2026, choosing the right hot-swap power supply (PSU) is about matching wattage to your server’s power draw and workload: 495W–800W PSUs are sufficient for entry-level servers (R450/R550/R660xs), 1100W–1400W PSUs are mainstream for mid-range servers (R660/R760), and 1800W–3200W PSUs are required for high-end servers with GPUs or high-TDP CPUs (R760xa/R770/R7725) — with 2800W topping out the 16G range and 3200W the ceiling on both 16G and 17G. This guide covers the 37 Dell hot-swap PSU part numbers we can verify across 13G–17G, plus the 3200W tier that 16G and 17G now share, and the label checks that separate a genuine unit from a relabelled one.
PSU basics: wattage, efficiency, and form factor
Three specs define a PSU:
- Wattage: the maximum power the PSU can deliver. Must exceed the server’s peak power draw (CPU + memory + storage + networking + GPUs). For example, a R760 with 2x 270W CPUs and 8x NVMe drives draws ~800W peak, so you need at least a 1100W PSU.
- Efficiency rating: 80 Plus Bronze/Silver/Gold/Platinum/Titanium. Higher efficiency = less waste heat and lower electricity costs. Titanium is the most efficient (up to 96% at 50% load), Platinum is mainstream (92–94%), Gold is budget-friendly (90–92%).
- Form factor: all PowerEdge hot-swap PSUs use the same physical form factor (1U or 2U chassis), but the connector pinout varies by generation. 13G/14G PSUs are compatible with 14G/15G servers; 16G/17G PSUs use a new connector and are not backward-compatible.
PSU by generation: 13G to 17G
37 verifiable Dell hot-swap PSU part numbers across five generations:
| Wattage | 80 Plus Rating | Compatible platforms | Part numbers |
|---|---|---|---|
| 495W | Platinum | 13G/14G (R630/R640/R730/R740) | 450-AEBM, 450-AHFI |
| 600W | — | 14G/15G (R640/R740/R650/R750) | 450-AKPR |
| 700W | Titanium | 15G/16G (R650/R750/R660/R760) | 450-AMJC, 450-AMIH, 450-BBMB, 450-BBLS |
| 750W | Titanium | 13G/14G (R630/R640/R730/R740) | 450-AEES, 450-AJRP, 450-AHOY |
| 800W | — | 15G/16G (R450/R550/R650/R660/R760XS) | 450-AKMG |
| 1100W | Platinum / Titanium | 12G–16G (R630–R760, R660xs, R6625) | 450-AEBL, 450-AKKX, 450-AKKY, 450-AKPJ, 450-AHPJ, 5G4WK (Platinum); 450-ALEM, 450-BBMC, 450-BBXG (Titanium) |
| 1400W | Platinum | 14G/15G (R750) — R660/R760 take 1400W under a separate P/N | 450-AKMJ, 450-AIYU, 450-AKYD, 450-AKPM |
| 1600W | Platinum | 13G/14G (R640/R740/R740XD/R940) | 450-AEPB, 450-AHPE |
| 1800W | Titanium | 16G (R660/R760/R7615/R7625) | 450-AMJM, 450-AMJE, 450-AMEX, 450-BBMH |
| 2000W | Platinum | 13G/14G (C4130/C4140/R740/R940) | 450-AENT |
| 2400W | Platinum / Titanium | 14G–17G (R740/R770/R7725) — R760 takes 2400W under a separate P/N | 450-AGFW, 450-AJPV (Platinum); 450-BDTN (Titanium, 17G); 450-BBXM (R960), 486-BBGE (T560) |
| 2800W | Titanium (200–240 VAC HLAC) | 16G only — R760/R760xa/R7625/C6600. No 17G server takes 2800W | 450-ALGT (LiteOn PRRWX) |
| 3200W | Titanium (277 VAC / 336 VDC) | 16G–17G — R760 (16G) and R770/R7715/R7725 (17G) | J0KHH (Delta DPN; the 450- sales number is issued per configuration — ask for it on the quote) |
Key takeaway: 1100W is the most populated tier (9 part numbers across Platinum and Titanium), covering 12G–16G mainstream servers. 2400W and 3200W are the high-end tiers — but they split by generation: 2800W exists only on 16G (R760/R760xa/R7625/C6600); 17G skips 2800W and goes to 3200W, which 16G R760 also takes. Buying a 2800W unit for an R770 or R7725 is a dead end.
Which part number fits your generation
Matching a PSU to a server starts with the generation, not the wattage. The 37 part numbers split into two physical families, and the families do not interchange:
- 13G–15G family (495W–2000W): flat 1U/2U caddy, older pinout. Covers R630/R730/R640/R740/R650/R750.
- 16G–17G family (800W–3200W): new caddy and pinout introduced with the 16G platform. Covers R660/R760/R760xa/R770/R7725. Note that 2800W is 16G-only, while 3200W runs on both 16G (R760) and 17G (R770/R7725).
1100W exists in both families — 450-AEBL (and the 12G/13G 5G4WK) on 13G/14G, 450-AKKX / 450-AKPJ / 450-AHPJ on 15G/16G, plus the Titanium variants 450-ALEM / 450-BBMC / 450-BBXG. They look similar, share the wattage, and are not interchangeable. This is the single most common sourcing error we see on used and grey-market PSUs: the seller quotes “1100W Platinum for PowerEdge” and ships the wrong family.
How to confirm before you buy:
- Read the label, not the listing. Genuine units carry the Dell P/N (e.g.
450-AEBM), the manufacturer P/N (e.g.Y6XYK), a serial number and a hologram. - Check the P/N against the platform, not the wattage. Dell’s support site returns the compatible platforms for a given P/N; our Dell PowerEdge power supplies page groups the units we stock by generation.
- Cross-check the connector. A 16G PSU will not seat in a 15G chassis even when the wattage matches.
Swapping wattages and mixing PSUs: the rules
Within one server, all installed PSUs must be identical — same P/N, same wattage, same efficiency class. Mixing a 1100W and a 1400W unit is not supported: the iDRAC reports a configuration error and the platform may refuse to enable redundancy.
Upgrading wattage is allowed, and is a normal refresh action — but only inside the same generation family:
| From | To | Verdict |
|---|---|---|
| 800W → 1100W (15G/16G) | same family, higher wattage | Supported; verify the PSU is in the platform’s option list |
| 1100W → 1400W (15G/16G) | same family, higher wattage | Supported; check PDU connector (C13 vs C19) |
| 1400W → 2400W (16G) | same family | Supported on platforms that list 2400W; C19 cabling required |
| 1100W (13G/14G P/N) → 16G chassis | different family | Not supported — wrong caddy and pinout |
| 495W → 2400W | far outside platform option list | Not supported — platform firmware will not validate it |
Downgrading wattage is where deployments break. A server configured with 2× 1400W and later “saved” with 2× 800W will boot, then throttle or shut down under load, and the iDRAC will log power-supply insufficiency rather than a clean failure. If you are replacing a failed unit, match the wattage — do not take the cheaper option because it physically fits.
Replacing a failed PSU: the five-point match
Hot-swap means you can replace a PSU with the server running, but only if the replacement matches on all five points:
- Generation family — 13G–15G or 16G–17G caddy.
- Wattage — identical to the surviving unit.
- Efficiency class — keep Platinum with Platinum. Mixing a Titanium unit into a Platinum pair is a configuration error on most platforms.
- Connector — C13 for 800W–1400W, C19 for 1800W–3200W; the PDU must supply the matching outlet.
- Firmware visibility — after insertion, confirm the new unit appears in iDRAC with a healthy status and that redundancy is restored. A PSU that seats and powers the server but is not enumerated is usually a counterfeit or a wrong-family unit.
Spare-parts practice: hold one matching spare per wattage class you operate, not one spare per server. Because all units in a class are interchangeable across platforms of the same generation family, a single 1100W Platinum spare covers every 15G/16G node in the rack.
How to read the label on a unit you were shipped
Most PSU sourcing errors are caught at one moment: when the box is open and the unit is in your hand. Learn what is printed on the side of the housing before you need it.
Where the label is. On the side shell of the housing, not on the rear handle and not on the front face. On an installed unit you have to release the latch and slide it partway out to read it. Photograph the label of every unit you receive, before installation — it is the only record you will have when a warranty claim comes up two years later.
What is actually printed there.
| Field | Example | Why it matters |
|---|---|---|
| Dell P/N | 450-ALGT | The number you order and quote against. This is the one that must match your platform’s option list. |
| Manufacturer P/N | PRRWX | The OEM’s own part number (LiteOn, Delta, Chicony, Artesyn). Different string, same unit. |
| Wattage and rating | 2800W, 80 Plus Titanium | Both must match; a Platinum unit cannot stand in for a Titanium one in a matched pair. |
| Input range | 200–240 VAC | Decides whether the unit delivers rated output on your feed. |
| Date code | 2023-08 | Age, and useful for judging capacitor life on a used unit. |
| Serial | alphanumeric | The only identifier Dell support will accept. |
The two-number trap. Dell P/N and manufacturer P/N are different strings for the same physical unit, and sellers routinely quote one while you are checking the other. If a listing shows only PRRWX, you cannot confirm platform fit from it — you need the 450- number. Ask for both, plus a photo of the label, before you commit. A seller who cannot produce a label photo is not a seller you want on a multi-unit order.
Check the hologram and the QR code. Genuine units carry both. The QR resolves to Dell’s verification path; a sticker that peels cleanly off in one piece, or a QR that lands on a generic page, is a red flag. Counterfeit 1100W Platinum units are common enough that we check every one.
Five PSU mismatches we catch most often
These are the five we see repeatedly on inbound purchase orders. Each one fits physically, powers on, and fails later.
- 1100W across the generation boundary.
450-AEBLand5G4WKare the 13G/14G units;450-AKKX,450-AKPJand450-AHPJare the 15G/16G units. Same wattage, same look — different caddy and pinout. This is the single most common grey-market substitution. - 2800W ordered for a 17G server. 2800W exists only on 16G (C6600, R760, R760xa, R7625). No 17G platform takes it. 17G goes from 2400W straight to 3200W, and a 2800W unit will not seat.
- 3200W on an ordinary 208 V feed. The 3200W part is a 277 VAC / 336 VDC unit; the 2800W is 200–240 VAC high-line. Neither delivers nameplate output on 208 V. Buying on wattage alone gets you a unit that derates to roughly the tier below.
- C19 PSU into a C13 PDU. 800W–1400W units draw on C13; 1800W–3200W units need C19. The PSU arrives, the rack does not accept it, and the project slips a week waiting on a power strip.
- 2400W ordered without checking the platform. There are five 2400W part numbers and they are not one product:
450-AGFWand450-AJPVare the 14G/15G units,450-BDTNis the 17G Titanium unit for R770/R7715/R7725,450-BBXMfits only the R960 and486-BBGEonly the T560 tower. Ordering “2400W for PowerEdge” gets you a unit that does not fit the rack server you meant.
Every one of these is a generation or connector question, not a wattage question. That is why the first column of our own Dell PowerEdge power supplies listing is the platform, not the wattage.
What “used” and “refurbished” actually mean for a PSU
A PSU is a wear item. The capacitors age, the fan bearing wears, and the unit that powered a lab bench for six years is not the same asset as one that ran a lightly loaded node for two. The word on the listing does not tell you which you are getting; the grade and the test record do.
| Grade | What it is | What to expect |
|---|---|---|
| New | Unopened, in Dell packaging | 3 years from us |
| New old stock | Unopened, out of production | 3 years from us; check the date code — capacitors age on the shelf too |
| Refurbished | Pulled unit, cleaned, fan and worn capacitors replaced, load-tested | 1 year from us |
| Pull | Working take-out, not refurbished | Quoted per lot; ask for the test record |
What we check before a PSU ships: label and hologram match the part number ordered, fan spins clean with no bearing noise, no scorching or electrolyte smell at the vents, iDRAC enumerates the unit with a healthy status, and a load test at the rated tier. The test record travels with the unit.
What you should check on arrival, even on a refurbished unit: seat it, confirm iDRAC shows it healthy and redundancy restored, then run your own load if the node matters. A PSU that powers a server but is not enumerated is the pattern we see on counterfeit and wrong-family units — it will run until the day it does not.
Request a quote for the right PSU
Choosing the wrong PSU leads to either insufficient power (server crashes) or wasted budget (over-provisioned PSU). Send us your server model, CPU configuration, memory, storage, and GPU options, and we’ll recommend the right PSU wattage, efficiency, and redundancy. See the current PowerEdge line servers page and the get a quote. All orders ship from China with worldwide delivery, with lead time and warranty terms fixed per contract.
Frequently Asked Questions
Can I mix different wattage PSUs in the same server?
No, all PSUs in a server must be identical (same wattage, efficiency, and part number). Mixing PSUs (e.g., 1100W + 1400W) is not supported and can cause instability or shutdowns.
Can I replace a failed 1400W PSU with an 800W unit that fits?
Physically it may seat, but it is not a valid configuration. The server will boot, then throttle or shut down under peak load, and the iDRAC logs power-supply insufficiency rather than a clean fault. Always match wattage and efficiency class when replacing.
Are third-party or compatible PSUs safe to use?
No. A third-party PSU is not validated against the platform’s power envelope, and an under-specified or counterfeit unit is a common cause of instability and thermal events. Use a genuine Dell PSU with the correct part number (P/N). Verify the P/N against the platform’s option list before ordering — our Dell PowerEdge parts hub lists what we stock by generation and wattage.
How do I know if a PSU is counterfeit?
Counterfeit PSUs often have misspelled labels, incorrect part numbers, or missing holograms. Genuine Dell PSUs have a holographic sticker, a QR code linking to Dell’s verification page, and a part number that matches Dell’s official compatibility list. If the price is too good to be true (e.g., 50% below market), it’s likely counterfeit.
What warranty and support terms should I expect for Dell PSUs?
A PSU supplied as part of a complete server follows that server’s term — 3 years on a new unit, 1 year on a refurbished one. A PSU bought on its own as a spare is quoted at 1 year from us unless the line item states otherwise, which matters when you are stocking spares across a fleet. Ask for the term per line item rather than assuming it carries over from the server. Terms: warranty and returns.
serverbastion.com

WeChat
Scan the QR Code with wechat